Bacharach MGS-408 Quick start guide

Show HTML Add to My manuals
2 Pages

Bacharach MGS-408 is a versatile gas detection controller that provides comprehensive information about the status of connected gas detectors. It allows connection of up to eight gas sensors and is compatible with various Bacharach gas detectors. With its customizable alarm delay, the MGS-408 ensures timely alerts for gas leaks. It offers analog output options for integration with external systems and features Bluetooth® Low Energy for wireless communication. The rugged IP66 enclosure ensures durability in harsh industrial environments.

advertisement

Bacharach MGS-408 Quick start guide | Manualzz
2. Safety Instructions (Continued)
Gas Detection Controller
for Commercial & Industrial Applications
WARNING: Extreme care should be exercised when
accessing the product’s interior. Only qualified electrical
maintenance personnel should perform connections
and adjustments. Always remove AC power before
working inside the MGS-408’s enclosure.
WARNING: Use a DRY CLOTH to clean the outside of this
product. DO NOT use soap and water or other detergents.
Failure to comply may result in a potential shock hazard.
CAUTION: The protection provided by this product may
become impaired if it is used in a manner not specified by
the manufacturer. Modifications to this instrument, not
expressly approved, will void the warranty.
CAUTION: Use ONLY the provided cable glands for
electrical and communication wiring. Drilling into the box
will void the warranty.
Refrigerant Leak Detection
P/N: 1100-2292 | February 2019 Revision 0
Quick Start
Guide
A certified AC power disconnect or circuit breaker should
be mounted near the controller and installed following
applicable local and national codes. If a switch is used
instead of a circuit breaker, a properly rated CERTIFIED
fuse or current limiter is required to be installed as per
local or national codes. Markings for positions of the
switch or breaker should state (I) for on and (O) for off.
CAUTION: In case of malfunction, DO NOT continue to use
this equipment if there are any symptoms of malfunction
or failure. In the case of such occurrence, de-energize the
power supply and contact a qualified repair technician or
the nearest Bacharach Service Center.
CODE COMPLIANCE: Comply with all local and national
laws, rules and regulations associated with this equipment.
Operators should be aware of the regulations and standards in
their industry / locality for the operation of the MGS-408.
TECHNICIAN USE ONLY: The MGS-408 must be installed
by a suitably qualified technician who will install this unit in
accordance with these instructions and the standards in their
particular industry / country. This document is only intended
as a guide and the manufacturer bears no responsibility for the
installation or operation of this unit.
Failure to install and operate the unit in accordance with
these instructions and with industry guidelines may cause
serious injury or death and the manufacturer will not be held
responsible in this regard.
4. Key Specifications
Size (H×W×D):
11.0″ × 8.5″ × 3.9″ (280 × 215 × 100
mm)
Power Supply:
100 - 240 VAC, 50 / 60 HZ, 80W
(maximum)
Weight:
2.76 lbs (1250 g)
Wiring (Power):
2-core cable, 16 to 28 AWG
Indicators:
Multi-color Status LED
Internal Alarm Buzzer: 72dB @ 3.9″ (10 cm)
Wiring (Relays):
2-core cable, 16 to 28 AWG
Wiring (Modbus):
1. Introduction
Alarm Delay:
Configurable (0 to 15 minutes)
The MGS-408 Gas Detection Controller displays
comprehensive information about the status of all
connected gas detectors. A maximum of eight (8) gas
sensors can be connected to the MGS-408 via Modbus RTU.
Compatible Bacharach gas detectors are the MGS-410,
MGS-450, MGS-460, MGS-250 and MGS-550.
Inputs:
Tactile Switches (×2), Magnetic
Switches (×2)
Recommended: Belden 3106A (or
equivalent) 3-core, 2 twisted pair +
ground, shielded cable with 120
Ω characteristic impedance, 16 to
28 AWG
Outputs:
Analog Output: 4 to 20 mA, 0 to 5V, 0 to
10V, 1 to 5V (default) or 2 to 10V
Enclosure:
Material: ABS
Protection: IP66
Bluetooth®
Bluetooth® Low Energy, BLE 4.2
Temperature:
32 to 113°F (0 to 45°C)
Modbus:
Connection: RS-485 terminal block
Baud Rate: 9,600 (default) or 19,200
Data Bits: 8
Parity: None (default), odd or even
Stop Bits: 1 (default) or 2
Retry Time: 500 ms (minimum)
Humidity:
5 to 90% RH, non condensing
Pressure:
23.6 to 32.5″Hg (800 to 1,100 mbar)
Elevation:
0 to 6,560′ (2,000 m) altitude
Languages
This quick start guide has been translated into the
following languages: Deutsch, Español, Français,
Italiano and Nederlands. To download a translated
document, scan here or visit http://bit.ly/2TbbFNb.
2. Safety Instructions
DANGER: The MGS-408 is NOT certified or approved for
operation in oxygen-enriched atmospheres. Failure to
comply may result in EXPLOSION.
WARNING: NEVER operate the MGS-408 without
connection to a protective ground. Failure to comply
may result in a potential shock hazard and is a
violation of electrical safety standards.
5. Mounting Template
5.118
FULL-SIZE MOUNTING
TEMPLATE
―
DO NOT RESCALE
8.996

advertisement

Related manuals

Download PDF

advertisement