TOA | DP-SP3 CE/CE-AU/CE-GB | manual | TOA DP-SP3 CE/CE-AU/CE-GB User manual

TOA DP-SP3 CE/CE-AU/CE-GB User manual
SOFTWARE INSTRUCTIONS
DIGITAL SPEAKER PROCESSOR
DP-SP3
Thank you for purchasing TOA’s Digital Speaker Processor.
Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.
TABLE OF CONTENTS
1. GENERAL DESCRIPTION OF
THE DP-SP3 PC SOFTWARE ................................................................... 4
2. FEATURES . ........................................................................................................... 4
3. RECOMMENDED PC REQUIREMENTS . ........................................... 4
4. INSTALLING THE DP-SP3 PC SOFTWARE .................................... 5
5. STARTING THE SOFTWARE .................................................................... 7
5.1. Starting from the Start Menu .................................................................................. 7
5.2. Starting from the Shortcut Icon . ............................................................................ 7
6. MAIN SCREEN AND MENU ITEM DESCRIPTION ...................... 8
6.1. Main Screen ........................................................................................................... 8
6.2. Menu Item Description . ......................................................................................... 8
7. CONFIGURATION SETTINGS ................................................................. 11
7.1. Creating the Unit ...................................................................................................
7.2. Deleting the Unit . .................................................................................................
7.3. Changing the Crossover Combinations ...............................................................
7.4. Changing the Crossover Slopes ..........................................................................
7.5. Name Setting .......................................................................................................
7.6. Storing the Unit Configuration as a Template ......................................................
7.7. Storing the Crossover Settings as a Template .....................................................
11
15
15
15
15
15
15
8. UNIT OPERATION . ......................................................................................... 16
8.1. Unit View ..............................................................................................................
8.2. Preset View . ........................................................................................................
8.3. Flow View ............................................................................................................
8.4. Contents View ......................................................................................................
8.5. Response view ....................................................................................................
8.6. Preset Memory Settings ......................................................................................
8.7. Level Monitor View ...............................................................................................
8.8. Mute View ............................................................................................................
16
17
18
19
34
37
40
41
9. USING THE PRESET G ............................................................................... 43
10. COMMUNICATIONS .................................................................................... 46
10.1. Method to Set Communications with the DP-SP3 Unit ...................................... 46
11. SPEAKER PARAMETER SETTINGS
USING A WEB BROWSER ..................................................................... 55
11.1. Speaker Parameter Settings ............................................................................... 55
12. SECURITY SETTINGS
............................................................................. 63
12.1. Enabling the User Level .................................................................................... 63
12.2. Logging on When the User Level is Enabled . .................................................. 64
12.3. Restriction Settings ........................................................................................... 65
13. DP-SP3’S MUTE SWITCH LOCK ON/OFF SETTING ........... 67
2
14. PRINTING THE SETTING DATA ......................................................... 68
15. CONTACT INPUT TERMINAL ............................................................... 69
15.1. General Description . ..........................................................................................
15.2. Contact-In Setting Screen Description ..............................................................
15.3. Function Assignment to the Contact Inputs .......................................................
15.4. List of Functions Assignable to Pins ..................................................................
69
69
71
74
3
1. GENERAL DESCRIPTION OF THE DP-SP3 PC SOFTWARE
This Software is designed to be used exclusively for setting parameters of acoustic signal processing functions
such as the compressor and filter functions for the DP-SP3 Digital Speaker Processor. Install the Software
program on a PC meeting the requirements below.
2. FEATURES
• Up to four DP-SP3 units can be controlled from a single PC with this Software installed.
• The DP-SP3 performs only its state indications, power ON/OFF operation, and muting operation, while this
Software performs other operations, settings, and state displays of the DP-SP3.
3. RECOMMENDED PC REQUIREMENTS
Install this Software on a PC meeting the requirements below.
Hardware Requirements
CPU
1.0 GHz, Intel Pentium 4 or higher
Display
1024 x 768 resolution or higher
Memory
Free Hard Disk Space
Optical Drive
LAN
Software Requirements
OS
Required Component
Over 1.0 GB
Over 16 MB
however, over 600 MB is required for the 32 bit version or over 1.5 GB for the 64
bit version when “.NET Framework” is not yet installed
CD-ROM drive or CD/DVD Multi-drive
Compatible to 10BASE-T or faster connection
32/64-bit Windows 7, 32/64 bit Windows 10
Following are the verified operating systems:
32-bit Windows 7 (Professional)
64-bit Windows 7 (Professional)
32-bit Windows 10 (Pro)
64-bit Windows 10 (Pro)
.NET Framework 4 Client Profile (Internet access is required when “.NET
Framework” needs to be installed)
• Pentium is the trademark of Intel Corporation in the United States and other countries.
• Windows and Windows Vista are the registered trademarks of Microsoft Corporation in the United States and
other countries.
• Regarding other company names and products, they are also trademarks of individual companies.
4
4. INSTALLING THE DP-SP3 PC SOFTWARE
Terminate all other application programs in operation before installation.
Follow the procedures below to install.
Step 1. Insert the supplied CD into the PC’s CD drive.
Step 2. Open the CD drive from the “Explorer” or “My Computer.”
The “English” folder, “Japanese” folder, and other contents are displayed.
Step 3. Open the “English” folder.
Step 4. Open the “Software” folder.
Step 5. Double-click the “setup.exe.”
The following window is displayed.
Step 6. Click the [Next] button.
The following window is displayed.
Check the contents of the License Agreement, then choose the “I Agree” or “I Do Not Agree” radio
button.
Choosing “I Agree” allows to click the [Next] button.
5
Step 7. Check the contents of the window, then click the [Next] button.
The following window is displayed.
Step 8. If necessary, change the folder into which the software will be installed, then click the [Next] button.
The following window is displayed.
Step 9. Start installation according to the instructions on the screen.
Note
If the .NET Framework is not installed in the PC, follow the on-screen instructions to install it.
Step 10. Click the “Close” button after installation completion.
The shortcut icon for the DP-SP3 GUI executable program is stored in the PC’s start menu.
6
[Uninstalling the DP-SP3 PC Software]
Step 1. Click the Start button on the PC’s desktop, and select [Setting
The “Control Panel” window is displayed.
Control Panel].
Step 2. Double-click the “Programs and Features” icon.
The currently installed program will then be displayed.
Step 3. Select “DP-SP3 GUI.”
Step 4. Click the Uninstall button to uninstall the software.
5. STARTING THE SOFTWARE
The following 2 different methods are available for starting the installed DP-SP3 PC Software:
5.1. Starting from the Start Menu
You can start the DP-SP3 PC Software from the start menu.
Click the Start button on the PC’s desktop, and select [Programs
GUI] to start.
TOA Digital Audio Control
DP-SP3
5.2. Starting from the Shortcut Icon
You can start the DP-SP3 PC Software by double-clicking the shortcut icon
installation completion.
created on the desktop after
7
6. MAIN SCREEN AND MENU ITEM DESCRIPTION
6.1. Main Screen
Starting the DP-SP3 PC Software causes the main screen to appear.
Tool bar
Flow view (See p. 18.)
Menu (See p. 8.)
Preset view (See p. 17.)
Unit view (See p. 16.)
Contents view (See p. 19.)
Status bar (See p. 64.)
6.2. Menu Item Description
6.2.1. File
New :
Open... :
Save :
Save As... :
Print Settings :
Print :
Print Preview :
Creates (sets) a new setting file.
Calls up the existing setting file.
Overwrites the setting file being edited.
Saves the setting file being edited under a different name.
Changes the page margin.
Prints the setting file onscreen.
Displays a preview of the setting file onscreen.
8
6.2.2. Edit
Undo :
Cancels the previous operation and returns to the original state.
Repeat :
Repeats processing previously performed.
Cut :Initializes the setting value after copying the setting value of the designated
box to the clipboard.
Copy :
Copies the setting value of the designated box to the clipboard.
Paste :
Pastes the clipboard data to the designated box.
Initial value :
Initializes the setting value of the box.
Set Grouping :
Performs the group setting of the box.
Release Grouping :
Cancels the group setting of the box.
Box Write Protect...
Off :
Sets no restriction on write to box.
Low :
Restricts the operator from changing the parameters set in the box.
Mid :
Restricts the operator from changing all settings in the box.
High :Restricts the administrator from changing the parameters set in the box, and
the operator from changing all settings in the box.
6.2.3. View
Toolbar :
Status Bar :
Unit View :
Contents View :
Response View :
Preset View
Show/hide :
Floating :
Docking :
Mute View
Show/hide :
Floating :
Docking :
Level Monitor View :
Shows or hides the toolbar.
Shows or hides the status bar.
Shows or hides the unit view.
Shows or hides the contents view.
Shows or hides the response view. (See p. 34.)
Shows or hides the preset view.
Floats the preset view window.
Docks the preset view window.
Shows or hides the mute view. (See p. 41.)
Floats the mute view.
Docks the mute view.
Shows or hides the level monitor view. (See p. 40.)
6.2.4. Unit
Create New Unit... :
Delete Unit :
Change X-over
Combination... :
Slope... :
Filter split :
Names... :
Save as a Template
Unit Template... :
X-over Template :
Input PAD settings :
Creates a new unit.
Click the flow view screen on the main screen to create the first unit.
Deletes the unit from the setting data.
Changes crossover combinations.
Changes crossover slopes.
Changes split settings of the output stage filter box.
Changes the names of the unit and its inputs and outputs.
Stores equipment configuration settings as a template.
Stores crossover settings as a template.
Changes the input sensitivity of the unit.
6.2.5. Preset
Change
Preset 1 – 16 :
Recalls one out of 16 preset memories.
Store
Preset 1 – 16 :
Writes setting contents in one of 16 preset memories.
Names... :
Changes the name of preset memory.
Switching Host... :Make settings to permit the unit’s Preset memory to be switched synchronously
when the Preset memory is switched at the M-864D or other DP-SP3 (Master
device).
9
6.2.6. Remote
Connect... :
Disconnect :
Connect the DP-SP3 to a PC for online processing.
Disconnects the DP-SP3 from a PC for offline processing.
Note
While in offline state, the contents changed by a PC are not reflected on the
settings of the DP-SP3.
Bulk Transmission :
Transmits data of the currently opened file to the unit.
Bulk Receiving :
Receives the DP-SP3’s internal date.
Automatic Connection :
Makes an automatic connection when the file is opened next time.
Firmware :
Displays the DP-SP3’s firmware version number. (Valid only when online)
Connection Settings :Allows you to perform network settings and to designate the unit’s IP address
to which this DP-SP3 PC Software can access.
6.2.7. Option
Security settings :
Sets the user level and the restriction of operations.
Preset G active settings :Performs area settings (Preset G) that can be commonly used for preset
memories 1 − 16.
Contact input settings :
Performs function settings regarding contact inputs.
Front Lock On/Off
Off:
Enables the DP-SP3 unit’s mute switch operation.
On:
Disables the DP-SP3 unit’s mute switch operation.
6.2.8. Help
Version Information :
Displays the DP-SP3 PC Software version number.
10
7. CONFIGURATION SETTINGS
After starting up this PC Software, create the first unit, then perform configuration settings.
In this PC Software, the data for which configuration settings are performed is referred to as “Unit.”
7.1. Creating the Unit
Step 1. Click [Click to add first unit] (flow view) area on the main screen.
The Unit Configuration setting screen is displayed.
Step 2. Enter a unit name, then select the Unit ID.
Up to 20 alphanumeric characters can be used.
When creating the unit from the template files already prepared, click [Create from Template], then click
the [Click Here] button located right of [File Path]. The dialog box for selecting the file is then displayed,
enabling file selection.
11
Step 3. Click the [Next] button.
Crossover combination screen is displayed.
Note: To set the crossover function, proceed to Step 4. Otherwise proceed to Step 6.
Step 4. Click the setting contents to perform the crossover combination settings.
Setting status is displayed in the window on the right side of the screen.
[3-way/2-channel (output 1 and 4) setting example]
12
Step 5. Click the [Next] button.
The Crossover Slope screen is displayed.
Setting status is displayed in the window on the right side of the screen.
Note
When using the template (See p. 15.), tick “Template” box and click the [Click Here] button on its
right. A dialog box for selecting the file is then displayed. If you select the file and click the [Finish]
button, the signal flow is displayed.
Step 6. Check to ensure that the setting is correct and click the [Finish] button.
The signal flow is displayed.
13
Step 7. Set the Input PAD.
7-1. Select “Unit
Input Pad Settings” from the menu when the communication
with the DP-SP3 unit is disconnected.
The Input PAD Setting screen is displayed.
7-2. Set each input sensitivity of Inputs 1 and 2, then click the [OK] button.
PAD ON: +4 dB*
PAD OFF: –10 dB*
* 0 dB = 0.775 V
Note
Input PAD setting can be operated only when connection to the DP-SP3 unit is not established.
To reflect the settings to the DP-SP3 unit after setting completion, establish the connection to the DPSP3 unit, then send the set data. (See p. 53.)
14
7.2. Deleting the Unit
The unit configuration already created can be deleted only when the PC is not in communication with the DPSP3.
Select the unit to be deleted in the unit view or flow view.
Select [Unit
Delete Unit] from the menu to display a dialog for confirmation.
Clicking the OK button deletes the unit.
7.3. Changing the Crossover Combinations
The configuration crossover combination already created can be changed only when the PC is not in
communication with the DP-SP3.
Select the unit for which you want to change the crossover combination in the unit view or flow view.
Select [Unit
Change X-over
Combination] from the menu to display the Crossover Combination screen.
Crossover combination settings can be changed in the same procedures as for creating a new unit configuration.
7.4. Changing the Crossover Slopes
Select the unit for which you want to change the crossover slopes in the unit view or flow view.
Select [Unit
Change X-over
Slope] from the menu to display the Crossover Slope screen.
Crossover slope settings can be changed in the same procedures as for creating a new unit configuration.
7.5. Name Setting
Select [Unit
Names] from the menu to display the Name setting screen.
Enter a name in the “Unit name” field on the Name setting screen, click the [OK] button to display the name in
the unit field.
7.6. Storing the Unit Configuration as a Template
The set equipment configuration can be saved as a template in the unit view or flow view.
Select [Unit
Save as a Template
Unit Template] from the menu to display the file storing screen.
Enter a file name in the file name field, then click [Store].
7.7. Storing the Crossover Settings as a Template
The set crossover box (example:
) can be saved as a template in the unit view or flow view.
Select [Unit
Save as a Template
X-over Template] from the menu, and the file saving screen is displayed.
Enter a file name in the file name field, then click [Store].
15
8. UNIT OPERATION
8.1. Unit View
The Unit View is located at the upper left of the main screen.
It displays up to 4 units in a list-view or in a tree-view style,
which can be switched by clicking the tab below.
Display view style
Tab name
List-view
Unit List
Tree-view
Unit Tree
Unit View
8.1.1. List view
Displays the signal processing images of the unit in a reduced size. (Up to 4 units)
Allows convenient displays of the unit names, numbers of inputs and outputs, matrix settings, and crossover
combinations.
Selecting the created unit by clicking on it displays the selected unit in the flow view as well.
In the List view display, the unit’s copy can be made by dragging and dropping the
created unit onto the blank unit.
8.1.2. Tree view
Each individual unit list is displayed in a tree view. (Up to 4 units)
Clicking the created unit displays the selected unit in a flow view as well.
16
8.2. Preset View
The preset view is located at the lower left of the main screen.
Preset view
It shows the preset memory names and the preset numbers being currently selected.
It is also possible to change, store, and compare the preset data.
Preset memory list
Change button
Store button
Compare button
• The currently selected preset memory number is displayed in bold in the preset memory list.
• To recall a preset memory, click the corresponding preset memory name and click the [Change] button. The
menu bar can also be used to recall. (See p. 37.)
• To write data into the preset memory, click the corresponding preset memory name and click the [Store]
button. The menu bar can also be used to write. (See p. 37.)
• To compare the preset memories, click the corresponding preset memory name and click the [Compare]
button.
The current preset setting temporarily switches to the selected preset setting. To compare with the status just
before editing, click the preset number displayed in bold and click the [Compare] button. To return the screen
to the original preset state, click the [Compare] button again.
• You can switch the preset view between docking and floating displays.
[Docking display]
Preset View
Docking] from the menu.
Select [View
[Floating display]
Select [View
Preset View
Floating] from the menu.
17
8.3. Flow View
The flow view displays the signal processing image
indicated by a signal flow chart consisting of the signal
processing functional boxes and input-to-output lines
connected between them.
Flow view
Unit name (See p. 16.)
Crossover (Xover) (See p. 27.)
: Low-pass filter
: High-pass filter
: Band-pass filter
Delay (See p. 31.)
Attenuator (See p. 33.)
Mute*1
Signal indicator*2
(High-pass filter + low-pass filter)
Gain (See p. 21.)
Compressor (See p. 23.)
Filter (See p. 25.)
Matrix (See p. 20.)
*1 Double-clicking on the mute box of the output displays “\” mark in the box, and switches the mute function for
that channel to OFF.
Mute ON :
Mute OFF :
Double-clicking the Mute ON box again switches the mute function to OFF.
18
*2 The display of the signal indicator changes depending on the signal levels at the input and output while the
PC is in communication with the DP-SP3.
LEVEL D
LEVEL B
LEVEL A
LEVEL C
• The indicator LEVEL A indicates the signal level immediately after analog-to-digital conversion obtained from
the unit.
• The indicator LEVEL B indicates the signal level obtained by adding the input gain value to the LEVEL A signal
level.
• The indicator LEVEL C indicates the signal level immediately before digital-to-analog conversion obtained
from the unit.
• The indicator LEVEL D indicates the signal level obtained by adding the output attenuator value to the LEVEL
C signal level.
Red:
Signal level is 18 dB or more.
Yellow: Signal level is 12 dB or more and less than 18 dB.
Green: Signal level is –40 dB or more and less than 12 dB.
8.4. Contents View
Clicking each box in the flow view causes each corresponding view to be displayed at the lower area of the flow
view.
Flow view
Contents view area
19
8.4.1. Matrix view
Clicking the Matrix box in the signal flow causes the Matrix view to be displayed.
Matrix control
Numerical value indication button
Fader
Level setting button
Example of numerical display
• A circle mark in the matrix control column shows input/output routing.
• The Matrix control turns on and off as it is double-clicked.
• A black, thicker frame on the Matrix control shows the selected matrix point.
• The level at the selected matrix point can be changed by moving a fader up or down.
• The level at the selected matrix point is displayed numerically on the Level setting button. Pressing this button
permits direct entry by a numerical value.
You can also change the level in 1 dB units with the Up and Down buttons located on the right side.
• The level setting at each matrix point is displayed numerically by clicking the [Numerical] button.
20
8.4.2. Gain view (Gain settings)
The Gain view appears if you click the
box in the signal flow.
[Gain view] (Former stage of input section)
(1)
(2)
(3)
(4)
(5)
(1) Grouping button [Grouping No.]
The group number is displayed when grouping has been set, and the “Off” indication is displayed when no
grouping has been set.
Clicking on this button permits grouping to be set or cancelled on the pull-down menu.
If you move a fader of a grouped channel up or down, the faders of other channels assigned the same group
also move in synchronization with the first operated fader.
Select either “New Group” or the number
of a group that has already been set.
Only when “New Group” has been selected, select either
“Same Value” or “Keep Offset.”
Same Value:Makes gain value within the group identical.
Keep Offset:Permits gain values to be changed without
changing the relative gain values within the
group set at the time of group setting.
21
(2) Fader
You can change the signal level of each channel by moving this fader up and down.
(3) Gain indication button [Gain (dB)]
Indicates each channel signal level in dB.
If you press this button, a dialog for gain setting is displayed,
enabling you to set the gain by directly entering a numerical
value.
(Setting range: –∞ to +12 dB)
You can also change the gain in 0.5 dB units with the Up and
Down buttons located on the right side.
(4) Reverse polarity button [Polarity]
Displays each channel’s polarity. Clicking this button permits the polarity to be reversed.
(5) Mute button [Mute]
Click this button to determine whether (ON) or not (OFF) to use the mute function.
Displays the ON/OFF setting status of the mute function for each channel.
22
8.4.3. Comp view
The Comp view is displayed if you click the
box in the signal flow.
[Single output display]
(1) Red mark (2) (3)
(4)
(5)
(6)
(7)
(8)
Display switch tab
[All output display]
Clicking the [All] tab causes the setting screen for all channels to appear.
(4)
(5)
(6)
(7)
(8)
(1) Threshold handle (Red indication mark)
Click and drag this threshold handle along a tilt line to change the threshold level. (Threshold).
(2) Ratio handle
Click and drag this handle up and down to change the ratio.
(3) Reduction level meter
Displays the reduction level (how much the compressor has worked) with a yellow bar graph on the reduction
meter.
Input/output signal level, reduction level (how much the compressor has worked), and threshold level are
displayed with a bar graph below while the DP-SP3 is operating online.
Threshold level
Input signal level
Reduction level
Output signal level
23
(4) Threshold button [Threshold (dB)]
Displays the compression threshold level for each channel by means of
numerical values.
The Up and Down buttons located on the right side can be used to change
the threshold level in 1 dB units.
Also, if you press this button, a dialog for threshold level setting is displayed
as shown at right, enabling you to set the level by directly entering a
numerical value.
(Setting range: –20 to +20 dB)
(5) Ratio button [Ratio]
Displays the compression ratio for each channel by means of numerical
values.
If this button is pressed, setting values can be selected from the pull-down
menu as shown at right.
The Up and Down buttons located on the right side can also be used to
change the value as shown at right.
(6) Sync button [Sync]
Sync for each channel is displayed on the Sync button.
If this button is clicked, selective input can be performed from the pull-down menu.
(7) Attach button [Attach Time (ms)]
Displays the compression attack time for each channel by means of numerical values.
Clicking this button permits setting values to be selected from the pull-down menu.
The Up and Down buttons located on the right side can also be used to change the value.
(8) Release button [Release Time (ms)]
Displays the compression release time for each channel by means of numerical values.
Clicking button permits setting values to be selected from the pull-down menu.
The Up and Down buttons located on the right side can also be used to change the value.
24
8.4.4. Filter view
Clicking the
(1)
box in the signal flow causes the Filter view to appear.
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
[Displayed in tabular form]
Clicking the Table indication button (No. 11) permits the filter control area to be displayed in tabular form.
(1)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(1) Filter control area
(2) Filter point symbol
Select the filter point from the filter point symbol as required.
If you right-click a point on the filter point symbol, the popup menu shown at right is
displayed.
Selecting each of the following filters causes a circle to appear on the filter control
area.
To cancel it, right-click the filter point symbol again and select “Through.” The circle on
the filter control area disappears.
A yellow circle indicates the selected filter point.
: Parametric equalizer (PEQ)
:High-pass filter (HPF)
: Low-pass filter (LPF)
: High shelving filter (High Shelving)
: Low shelving filter (Low Shelving)
: All-pass filter (All Pass)
: Low shelving filter (Low Shelving)
: All-pass filter (All Pass)
You can change the frequency and the gain if you drag the filter point on the filter control area.
When a white circle is displayed on the left side of the filter point, by clicking and dragging the white circle up
and down, the Q value of the selected filter point can be changed.
25
(3) Filter type indication button
Indicates the type of filter of the selected filter point.
Click this button to select the type of filter from the pull-down menu.
Selecting “Through” causes the circle to disappear from the filter control area.
(4) Frequency indication button [Freq. (Hz)]
Displays the frequency of the selected filter point.
If you click this button, a dialog for frequency setting is displayed, enabling
you to set the frequency by directly entering a numerical value.
(Setting range: 20 – 20,000 Hz)
The setting can also be changed in 1/24 octave units (this step width can be
changed with the Option button) with the use of the Up and Down buttons
located on the right side.
(5) Gain indication button [Gain (dB)]
Displays the gain of the selected filter point.
If you click this button, a dialog for gain setting is displayed, enabling you
to set the gain by directly entering a numerical value.
(Setting range: –15 to + 15 dB)
The setting can also be changed in 0.5 dB units (in 0.1 dB units using the
Option button) with the use of the Up and Down buttons located on the
right side.
(6) Q indication button [Q]
Displays the Q value of the selected filter point.
Clicking this button permits the setting value to be selected from the pull-down menu.
(7) Bypass ON/OFF button
Displays ON/OFF status of the selected filter.
The Bypass function turns on and off as it is clicked.
(8) Bypass all ON/OFF button
Displays ON/OFF status of the selected filter box.
The Bypass all function turns on and off as it is clicked.
Turning ON disables all set filters.
Turning OFF this button enables all filters set to ON.
(9) Frequency response indication button
Used to show or hide the Response View (See p. 34.)
(10) Option button
The pull-down menu at right is displayed if
you click this button.
Scale:
Scale can be changed.
Q-Display:
The method to indicate the Q value can be changed by
selecting “Value” or “Octave Band”.
(Available only when the parametric equalizer, notch filter
or all-pass filter is selected.)
“Fraction” and “Value” displays are available for the
“Octave Band” display.
Fine Resolution:
Selection of “Frequency” permits the frequency step width
to be changed.
If “Gain” is selected, the gain step width can be changed.
(11) Table indication button
Clicking this button permits the filter control area to be displayed in tabular form.
To return the screen to the original graphical display, click this button again.
26
8.4.5. Xover view (Crossover function settings)
The Xover View is displayed if the
,
, or
box of Xover is clicked in the signal flow.
[Crossover function settings ]
The screen of the [Xover] tab is first displayed if the box of Xover is clicked.
(2)
(1)
(3)
(4)
(5)
(8)
(9)
(10)
The indication displayed at the upper right of the screen changes depending on the type of selected filter.
(1) When “12 dB Variable-Q” or “18 dB Variable-Q” is selected
(3)
(4)
(5)
(2) When “24 dB Variable-Q” is selected
(3)
(4)
(5)
(6)
(3) When other filter type than those stated above is selected
(3)
(4)
(4) When “Gain” is selected
(6)
(7)
27
[Displayed in tabular form]
Clicking the Table indication button (No. 8) permits the filter control area to be displayed in tabular form.
(1)
(3)
(4)
(5)
(8)
(9)
(10)
(1) Filter control area
(2) Filter point
A circle on the filter control indicates the operable filter point.
A yellow circle indicates the selected filter point.
(When selected),
(When selected),
(When not selected): High-pass filter
(When not selected): Low-pass filter
(When selected),
(When not selected): Gain control
You can change the cut-off frequency of the selected filter point if you click and drag the low-pass or highpass filter point left and right.
To change the gain of the selected filter point, click and drag the gain control point up and down.
When a white circle is displayed on the right or left side of the filter point, if the white circle is clicked and
dragged up and down, the Q value of the selected filter point can be changed.
(3) Filter type indication button
Displays the type of filter of the selected filter point.
Clicking this button permits the filter type to be selected from the pull-down menu.
(4) Frequency indication button [Freq. (Hz)]
Displays the frequency of the selected filter point.
If you click this button, a dialog for frequency setting is displayed, enabling
you to set the frequency by directly entering a numerical value.
(Setting range: 20 – 20,000 Hz)
The Up and Down buttons located on the right side can also be used to
change the frequency setting.
(5) Q/Q2 indication button [Q, Q2]
Displays the Q value of the selected filter point.
Clicking this button permits a setting value to be selected from the pull-down menu.
(6) Gain indication button [Gain (dB)]
Displays the gain of the selected gain control point.
If you click this button, a dialog for gain setting is displayed, enabling you
to set the gain by directly entering a numerical value.
(Setting range: –15 to +12 dB)
The Up and Down buttons located on the right side can also be used to
change the value in 0.5 dB units.
28
(7) Reverse polarity button [Polarity]
Displays the polarity of the selected filter point when the gain control is selected.
Press this button to reverse the polarity.
(8) Table indication button
The filter control area is displayed in tabular form if this button is clicked.
To return the screen to the original graphical display, click this button again.
(9) Frequency response indication button
Used to show or hide the Response View (See p. 34.)
(10) Scale change button
If you click this button, a dialog for scale setting is displayed, enabling
you to change the graph scale of the filter control area.
29
[Time correction settings between Xover boxes]
If you click the [Driver Alignment] of the Display Switch tab, the setting screen for time correction between Xover
boxes is displayed.
(1)
(2)
(3)
(4)
(5)
(6)
(1) Minimum variation unit selection button
Selects the minimum units of the delay time that can be changed with the Up and Down buttons.
(2) Option button
If you click this button, a delay option dialog is displayed and you can
select the unit of distance displayed on the delay distance indication
button from meters, inches and feet.
You can also set the temperature on the basis of which the delay
distance displayed is calculated.
(3) Local grouping button [Local Grouping]
Displays grouping within the channels for which Crossover Setting
has been performed.
The group symbol is displayed when grouping has been set, and the
“Off” indication is displayed when no grouping has been set.
Clicking this button permits local grouping to be set or cancelled on
the pull-down menu.
(4) Delay time indication button [Time (ms)]
Displays the delay time in each channel by means of a numerical
value.
If you press this button, a dialog for delay time setting is displayed,
enabling you to set the delay time by directly entering a numerical
value.
(5) Delay distance indication button [Distance (meters/inches/feet)]
Displays the delay distance in each channel by means of a numerical
value.
If you click this button, a dialog for delay distance setting is displayed,
enabling you to set the delay distance by directly entering a numerical
value
(6) Up/Down button
Changes the delay time in minimum variation units. .
30
8.4.6. Delay view (Delay function settings)
If you click the
box in the signal flow, the Delay View is displayed.
(1)
(2)
(3)
(4)
(5)
(6)
(1) Minimum variation unit selection button
Selects the minimum units of the delay time that can be changed with the Up and Down buttons.
(2) Option button
If you click this button, a delay option dialog is displayed and you can
select the unit of distance displayed on the delay distance indication
button from meters, inches, and feet.
You can also set the temperature on the basis of which the delay
distance displayed on the delay distance indication button is
calculated.
(3) Grouping button [Grouping No.]
The group number is displayed when grouping has been set, and the “Off” indication is displayed when no
grouping has been set.
Clicking this button permits grouping to be set or cancelled on the pull-down menu.
If you increment or decrement the value of each setting item of the grouped channel, other setting values
assigned the same group also increment or decrement in synchronization.
Select either “New Group” or
the number of a group that has
already been set.
Only when “New Group” has been selected, select
either “Same Value” or “Keep Offset.”
Same Value:Makes gain value within the group
identical.
Keep Offset:Permits gain values to be changed
without changing the relative gain
values within the group set at the
time of group setting.
31
(4) Delay time indication button [Time (ms)]
Displays the delay time in each channel by means of a numerical
value.
If you press this button, a dialog for delay time setting is displayed,
enabling you to set the delay time by directly entering a numerical
value.
(5) Delay distance indication button [Distance (meters/inches/feet)]
Displays the delay distance in each channel by means of a numerical
value.
If you click this button, a dialog for delay distance setting is displayed,
enabling you to set the delay distance by directly entering a numerical
value
(6) Up/Down button
Changes the delay time in minimum variation units.
32
8.4.7. ATT view
If you click the
box in the signal flow, the ATT View is displayed.
(1)
(2)
(3)
(4)
(1) Grouping button [Grouping No.]
The group number is displayed when grouping has been set, and the “Off” indication is displayed when no
grouping has been set.
Clicking on this button permits grouping to be set or cancelled on the pull-down menu.
If you move a fader of a grouped channel up or down, the faders of other channels assigned the same group
also move in synchronization with the first operated fader.
Select either “New Group” or
the number of a group that has
already been set.
Only when “New Group” has been selected, select either “Same
Value” or “Keep Offset.”
Same Value:Makes gain value within the group identical.
Keep Offset:Permits gain values to be changed without
changing the relative gain values within the group
set at the time of group setting.
(2) Fader
The signal level of each channel can be changed by moving the Fader up and down.
(3) Level indication button [Level (dB)]
Displays the signal level of each channel by means of numerical values.
If you click this button, a dialog for level setting is displayed, enabling
you to set the level by directly entering a numerical value.
(Setting range: -∞ - 0 dB)
The Up and Down buttons located on the right side can also be used to
change the value in 1 dB units.
(4) Mute button [Mute]
Click this button to determine whether (ON) or not (OFF) to use the mute function.
The ON/OFF status of the mute function for each channel is displayed on the Mute button.
33
8.5. Response view
Select [View
Response View] from the menu or click the
Frequency response indication button on the Filter (See p. 25.), or
Xover View (See p. 27.) to show or hide the Response View.
The Response View can display the Output response and Xover
response. The Xover Response View is displayed only when the filter
box is selected in the flow view.
Response View
8.5.1. Output response view
Displays an overall response from input to output.
Permits selection of Inputs routed by matrix for each output channel.
Permits display of 3 types of responses: amplitude, phase and group delay responses
(1)
(2)
(3)
(4)
(5)
(1) Response indication selection button
Displays the types of frequency responses being currently displayed.
If this button is clicked, the type of frequency response to be displayed can be selected from the pull-down
menu.
There are a full-screen display that displays any one of amplitude, phase and group delay responses, and
a dual-split screen display that displays two of these 3 responses.
(2) Scale change button
If you click this button, a dialog for scale setting is then displayed
and the graph scale of the response control can be changed.
(3) Response indication area
34
(4) Input selection button [Output 1 − 6]
Click this button to select either ON or OFF of response display of each output channel, or input channel
from the pull-down menu.
(5) Color change button
If this button is clicked, a dialog for color setting is displayed, permitting the
display colors of response curves of each channel to be changed.
8.5.2. Xover response view
Displays crossover and filter response curves.
Displays each channel response, as well as their added overall response.
Displays the amplitude response, phase response, and group delay response.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(1) Response indication selection button
Displays the type of frequency response being currently displayed.
If this button is clicked, the type of frequency characteristic to be displayed can be selected from the pulldown menu.
There are a full-screen display that displays any one of amplitude, phase and group delay responses, and
a dual-split screen display that displays two of these 3 characteristics.
35
(2) Scale change button
If you click this button, a dialog for scale setting is then displayed and
the graph scale of the response control can be changed.
(3) Measuring data import button
You can simulate crossover settings of the multi-way speaker by importing measuring data obtained by
other measuring software.
Click this button to select the target channel from the pull-down menu.
(4) Measuring data calibration button
Click this button to display a dialog for response display calibration.
Change [Amplitude] to calibrate the amplitude response, and [Receive
Delay] to calibrate the phase response.
(5) Response display area
(6) Response indication button
Click this button to select whether or not to display each channel’s response.
(7) Bypass button
Click this button to select whether or not to add each channel’s response to an overall response.
(8) Color change button
If this button is clicked, a dialog for setting color is displayed, allowing
the display color of each channel’s response curve to be changed.
(9) Overall characteristic indication button
Click this button to select whether or not to display an overall response comprised of added responses of
each channel.
36
8.6. Preset Memory Settings
There are 16 preset memory patterns. You can freely recall them or write data into them.
8.6.1. Recalling the preset memory
Select [Preset
Change
Preset 1 − 16] from the menu.
It is also possible to recall from the Preset View. (See p. 17.)
8.6.2. Writing data into the preset memory
Store
Preset 1 − 16] from the menu.
Select [Preset
It is also possible to write on the Preset View. (See p. 17.)
37
8.6.3. Preset Memory settings at power-on
Power On” from the menu, then select “Resume,”
Select “Preset
“Last Preset,” or “Preset 1 to 16” (Preset number).
Resume: Activates the DP-SP3 in the state just before poweroff.
Last Preset:Activates the DP-SP3 with the Preset memory
setting data selected just before power-off.
Preset 1 – 16:Activates the DP-SP3 with the setting data of the
selected Preset memory.
After completion of the setting, establish connection with the DP-SP3
(See p. 53.) and send the set data to it. Then, the setting contents
are reflected in the DP-SP3 when its power is switched on next time.
8.6.4. Names
Step 1. Select [Preset
Names...] from the menu.
The Name Preset Setting screen is displayed.
Step 2. Enter the name, then click the [OK] button.
Note: Up to 20 alphanumeric characters can be used.
38
8.6.5. Preset memory switching host settings
Preset memory interlock function allows the unit’s Preset memory to be switched synchronously when the
Preset memory of the M-864D or other DP-SP3 unit (Master device) is switched.
Step 1. Select “Preset
Switching Host...” from the menu.
The Preset Switching screen is displayed.
Step 2. Tick the “Enable Preset Switching” check box, then set the IP
address of the Preset interlock origin device (M-864D or DPSP3 that functions as a Master).
Step 3 Click the [OK] button.
The unit’s Preset number changes synchronously when the
Preset number at the Master side is changed.
2
3
39
8.7. Level Monitor View
The Level Monitor View window permits monitoring of the unit’s input and output signal levels while the PC is in
communication with the DP-SP3.
• Levels of up to 4 units can be displayed.
• Displays the levels of 2 inputs and 6 outputs for each unit.
• Displays the value of LEVEL A (See p. 19.) of the signal indicator in the Flow view as input level.
• Displays the value of LEVEL D (See p. 19.) of the signal indicator in the Flow view as output level.
Input level
Output level
40
8.8. Mute View
It is possible to mute all or individual DP-SP3’s outputs simultaneously by way of communication connection
established using the DP-SP3 PC Software.
8.8.1. Displaying a Mute view
Mute view can be displayed using either of the following two methods.
[Docking display]
Select [View
Mute View
Mute ON
Docking] from the menu.
Mute OFF
41
[Floating display]
Select [View
Mute View
Mute ON
Floating] from the menu.
Mute OFF
8.8.2. Mute view operation
The Mute view can be operated only while online with the DP-SP3 unit.
Mute ON/OFF data obtained through the Mute switch operation on the DP-SP3 unit’s front panel is reflected in
this view.
Also, the setting and reset data obtained through operations on the Mute view are reflected to the indication
statuses of the unit’s front panel-mounted output level indicators.
All mute button
Individual mute buttons (Output 1 through 6 from left to right)
42
9. USING THE PRESET G
The Preset G, a memory that is different and independent from the Preset memories 1 through 16, can be
shared by these Preset memories.
By setting the parameters to be shared as Preset G, they can be commonly used by multiple Preset memories.
Each Preset memory retains its own original parameters. Cancelling the Preset G setting causes the original
parameters to be enabled.
When controlling multiple units, parameters set in the Preset G are simultaneously set to their all preset G.
The setting procedures for the Preset G are as follows.
Step 1. Display the Preset memory that includes the parameters to be shared on the screen.
Confirm that the “Store” button is disabled.
If the “Store” button is enabled, click the “Store” button to store the Preset memory currently being
recalled.
(Example when the Preset 1 is displayed)
43
Step 2. Click “Option
Preset G enable settings” from the menu bar.
The “Enable Preset G” screen is displayed.
Step 3. Select the Preset memory that intends to use the common parameters, then place checkmarks in the
parameter boxes.
To place checkmarks collectively throughout all Preset memories, perform setting on the screen
displayed when the ALL tab is clicked.
(Example when checkmarks are placed in the Preset 1’s Gain, Filter, and Delay boxes)
44
(Example when a checkmark is placed
in the Preset 2’s Gain box)
(Example when checkmarks are placed
in the Preset 3’s Filter and Delay boxes)
Step 4. Click the “OK” button on the “Enable Preset G” screen.
Setting is completed, and the screen returns to the display in Step 1.
The boxes corresponding to the set parameters are displayed in orange.
Step 5. To cancel the Preset G setting, return to Step 2, select the corresponding Preset memory, uncheck the
desired parameter checkboxes, then click the “OK” button.
For the cancelled parameters, the original parameters of the selected Preset memory become enabled.
45
10. COMMUNICATIONS
This PC Software enables communications between a PC and the DP-SP3 unit via TCP/IP.
10.1. Method to Set Communications with the DP-SP3 Unit
10.1.1. Communication setting procedures between a PC and the DP-SP3 unit
Step 1. Select [Remote
Connection Settings] from the menu to display the “Check IP Settings” screen.
The screen below shows that 2 devices are detected as connectable devices.
46
[When the communication setting is not configured correctly]
When the network address of a PC running this PC Software and that of the DP-SP3 unit are not
identical, such device is listed in the “Other Network Devices” field as shown below, so that this PC
Software cannot operate this DP-SP3.
When IP addresses of the multiple DP-SP3 units are duplicated, such devices are listed in “Unconnectable
Devices,” so that this PC Software cannot operate them.
47
[Correcting the communication setting]
Retry setting with the procedures below.
(1) Select the device with an incorrect or duplicated IP address and click the [Modify IP Setting] button,
then the “IP Setting” screen is displayed. Enter the correct IP address.
Note: In this case, the network address of the PC running this PC Software is mandatorily designated.
Note: To perform default gate way setting, tick the [Enable edit of the “Default Gateway”] checkbox.
(2) To reflect the modified IP setting into the DP-SP3 unit, click the [Send Modified Settings] button.
48
The modified IP setting is sent to the DP-SP3 unit, thereby being reflected in the DP-SP3.
Step 2. When performing connection to the DP-SP3 unit via router, click the [Add] button, then manually set the
connected device.
49
Step 3. If there is any DP-SP3 unit to be removed from the connected device list, select such DP-SP3 unit from
the list, then click the [Remove] button.
Step 4. Click the [Next] button.
The “Check Firmware Version” screen is displayed.
If all connected devices are in controllable state, the screen below will appear.
50
(1) If the DP-SP3 unit uncontrollable due to its firmware version problem is found, such unit is shown on
the “Uncontrollable Devices” list. To make it controllable, click the [Update Firmware Version] button.
(2) Click the [Next] button in the “Check Firmware Version” screen, then the “Check Unit ID” screen is
displayed.
The screen below shows that all connected devices are in controllable state.
51
Step 5. To change ID, click the [Modify Unit ID] button.
All the DP-SP3 units’ ID is factory-preset to “1.” In this case, the Unit ID setting screen is displayed as
shown below.
Step 6. Click the [Finish] button.
52
10.1.2. Communication procedures between a PC and the DP-SP3 unit
Step 1. Select one of the followings from the menu, and detect the connected device.
• [Remote
Connect...]:Set the transfer direction when the setting data between a PC and
the DP-SP3 unit are different.
• [Remote
Bulk Transmission]: Transmits all setting data from a PC to the DP-SP3 unit.
• [Remote
Bulk Receiving]:
Transmits all setting data from the DP-SP3 unit to a PC.
(Available only when the created unit does not exist in the setting
data on this PC Software)
When “Connect...” is selected from the menu, the PC Software compares the contents of the setting
data between a PC and the DP-SP3 unit, and the indication “Different” is displayed in the State column
if they are not identical.
53
Step 2. To transmit the setting data, select [PC>>Unit] or [Unit>>PC], then click the [Update] button.
Data transfer starts.
Step 3. After completion of data transfer, click the [Complete] button.
To end communication, select [Remote
Disconnect] from the menu.
54
11. SPEAKER PARAMETER SETTINGS USING A WEB BROWSER
Operations shown below can be performed using a Web browser.
• Preset number selection
• Crossover settings
• Matrix settings
11.1. Speaker Parameter Settings
11.1.1. Displaying a Web browser’s top page
Enter the IP address of the DP-SP3 for which speaker parameters are to be set in the URL input field of the
Web browser.
The top screen for the DP-SP3 Speaker parameter settings is displayed.
IP address
Note
While the DP-SP3 is in communication with the PC Software, this setting cannot be performed and the screen
below is displayed.
55
11.1.2. Changing the Preset number
Step 1. Click on the “Preset No. Setting” text on
the Web browser’s top page.
Preset No. Setting screen is displayed.
Step 2. Select the Preset No. to be changed to.
Step 3. Click the [Apply] button.
3
2
Changed settings are reflected in the DPSP3 unit.
Note
Clicking on the “Top” text returns to the top page.
56
11.1.3. Xover combination settings
Crossover settings can be performed by selecting the preset Speaker parameters in the DP-SP3.
Step 1. Click on the “Xover Combination Setting”
text on the Web browser’s top page.
The Xover Combination Setting screen is
displayed.
2
Step 2. Set the Crossover combinations of the
desired channel.
Select “Single,” “2-Way,” or “3-way.”
Step 3. Select the speaker to be used from the
“Template” list.
Crossover combinations are set for
individual channels.
Tips
• Preset data (Speaker preset data) of the
Crossover and output equalizer values
are contained in the “Template” list for
each individual TOA speakers.
• It is also possible to create the Speaker
preset data and add the data to the
“Template” list. (See p. 60.)
4
3
Step 4. Click the [Apply] button.
Changed settings are reflected in the DPSP3 unit.
Note
Clicking on the “Top” text returns to the top page.
57
11.1.4. Matrix setting
Step 1. Click on the “Matrix Setting” text on the
Web browser’s top page.
The Matrix Setting screen is displayed.
Step 2. Set On or Off to the desired cross point of
the input and output.
Step 3. Click the [Store] button.
2
3
Changed settings are reflected in the DPSP3 unit.
Note
Clicking on the “Top” text returns to the top page.
58
11.1.5. Confirming the changed data
To confirm the changed data, establish connection with the DP-SP3 unit (See p. 53.) using the PC software.
Note
JavaScript may be disabled depending on the Web browser’s setting.
When the connection is established under such conditions, the screen as shown below is displayed.
Change the Web browser settings, then connect the DP-SP3 unit using the PC Software again.
59
11.1.6. Creating the Speaker preset data by yourself
It is possible to save the Crossover template file (See p. 15) created using the PC Software into the unit as
the custom template data.
Note
When saving the Crossover template file, be sure to name
the title in addition to the file name. The title name of the
Crossover template file becomes the speaker preset data
name. There is no limit to the type of input characters of the
title name.
[Adding the custom template]
Step 1. Click on the “Custom Parameter Setting”
text on the Web browser’s top page.
The Custom Parameter Setting screen is displayed.
Step 2. Click the [Add] button.
The Add Parameter screen is displayed.
Step 3. Select the preset Crossover template file, then click the
[Apply] button.
60
The Add Parameter completed screen is displayed.
Step 4. Check that the Parameter has been added.
You can confirm the newly added parameter on the
Custom Parameter Setting screen that appears by
clicking on the “Custom Parameter Setting” text.
[Deliting the custom template]
Step 1. Click on the “Custom Parameter Setting”
text on the Web browser’s top page.
The Custom Parameter Setting screen is displayed.
Step 2. Click the [Remove] button of the parameter to be deleted.
61
The Remove Parameter screen is displayed.
Step 3. Click the [Apply] button.
The Remove Parameter completed screen is displayed.
Step 4. Check that the Parameter has been deleted.
You can confirm that the designated Parameter has been
deleted on the Custom Parameter Setting screen that
appears by clicking on the “Custom Parameter Setting”
text.
[Using the Custom template data]
The added custom parameters are displayed in
the selection list as speaker preset data on the
Xover Combination Setting screen (See p. 57).
The title name of the Crossover template file
becomes the speaker preset data name.
The name is prefixed and postfixed with an
asterisk (*) to indicate that the set parameter is a
custom one.
62
12. SECURITY SETTINGS
The DP-SP3 PC Software features the following 2 different user levels that can be used in the Restriction
Settings explained in the next section.
• Administrator: If the user level is not set, Administrator is automatically selected for the level. Logging on as
an administrator on the logon screen also sets the user level to Administrator.
• Operator:
If you do not log on as an administrator on the logon screen, the user level is set to Operator.
12.1. Enabling the User Level
Step 1. Select [Option
Security Settings] from the menu.
A dialog for the user level and restriction settings is displayed.
Step 2. Tick the “Enable User Level” checkbox.
A dialog for administrator password settings is displayed.
Step 3. Enter a password (up to 16 characters in length) in the [Password] and [Confirm Password] fields, then
click the [OK] button.
63
12.2. Logging on When the User Level is Enabled
The following logon screen is displayed when the data file is opened after the user level has been enabled.
When logging on as an administrator, enter a set password and click the [OK] button.
If a different method than this is used to close the logon screen, the user level is logged on as an operator.
The level logged on is displayed on the right side of the status bar located at the lower part of the main screen.
or
64
12.3. Restriction Settings
12.3.1. Operations that can be restricted
• Creation and deletion of the unit and input/output change
• Crossover combination change
• Grouping change
• Name change
• Storage in preset memory
• Parameter change for each box
12.3.2. Performing restricted settings
Step 1. Select [Option
Security Settings] from the menu.
The Security Settings dialog is displayed.
Step 2. Select the restriction level from the pull-down menu of each item of Restriction settings.
65
You can set 4 different levels of restrictions for each item.
Off
Both administrators and operators can change the item and Restriction settings.
Mid
Administrators can change the item and Restriction settings. Operators cannot change the
item and Restriction settings.
Low
Administrators can change the item and Restriction settings. Operators cannot change the
item, but can change Restriction settings.
High Administrators cannot change the item, but can change Restriction settings. Operators cannot
change the item and Restriction settings.
For “Store to Presets,” different restriction settings can be assigned to each of 16 presets.
If you select “Preset” from the “Store to Presets” item’s pull-down menu, the “Restriction of store” dialog
for each preset is displayed, enabling you to set 4 different restriction levels for each preset.
66
Step 3. Perform restriction setting of parameter change for each box.
Select [Edit
Box Write Protect...] from the menu while the box is selected in the flow view.
Example: When performing restriction setting of the filter box
13. DP-SP3’S MUTE SWITCH LOCK ON/OFF SETTING
The DP-SP3 unit’s front panel-mounted Mute switch operations can be disabled.
Step 1. Place the PC in communicate with the DP-SP3 of which Mute
switch you want to lock.
Step 2. Select “Option
Front Lock On/Off
On or Off” from the
menu.
On: Disables the mute switch operation.
Off: Enables the mute switch operation.
If any mute switch is operated when the mute switch operation is disabled, the RUN indicator flashes green.
DP-SP3
RUN indicator
Mute switches
67
14. PRINTING THE SETTING DATA
The setting data of the file being edited can be printed.
Step 1. Select [File
Print] from the menu.
Dialog for print area is displayed.
Step 2. Set the unit to be printed.
Select “Created” to print the created data of all the units.
To print the data of the arbitrary units, select “Selected,” then click on the button of the units to be
printed.
Step 3. Set the preset to be printed.
Select [All] when printing all the data stored in 16 presets.
To print the data of the arbitrary presets, select “Selected,” then click on the button of the presets to
be printed.
Note
If you do not want to print the default values for the Filter or Xover, click “Do not print the default values”
check box. This will save the number of the printout sheets and printing time.
Step 4. Press the [OK] button.
68
15. CONTACT INPUT TERMINAL
15.1. General Description
The DP-SP3 unit is equipped with 4 contact input terminals that permit preset memory change, output volume
control, and output mute control to be performed.
Present memory change function has been assigned by default; Pins 1 through 4 are assigned to Preset Nos. 1
through 4, respectively. Preset Nos. 1 through 4 can be individually recalled by shorting the terminals 1 through
4 to terminal C.
To perform change in Preset number to be recalled and changes to other functions, use the Contact-in setting
screen.
15.2. Contact-In Setting Screen Description
Select [Option
Contact input settings] from the menu to perform contact input settings.
(1)
(2)
(3)
(4)
(5)
(6)
(1) Mode
Direct and Binary modes are available to assign input types to each Pin.
Direct: Controls by shorting each of Pins 1 through 4 to Terminal C.
Binary: Controls by shorting or opening between arbitrary ones of Pins 1 through 4 and Terminal C.
When setting to Binary, conduct settings in order from Pin 4.
(2) Function
Assign functions to each individual Pin.
“Preset” is assigned to all Pins as default.
Preset:
Preset memory change
Volume Up/Down: Output volume control
Mute:
Output mute
None:
No function is assigned to the Pin.
(3) Parameter
Set the corresponding Preset number when Pin’s function is assigned to “Preset,” and “Step” when assigned
to “Volume Up/Down.”
(4) Control
Perform control setting only when “Mute” function is assigned to the Pin.
Make: Mute is turned ON by shorting each Pin to Terminal C and turned OFF when released.
Pulse: Mute is switched between ON and OFF each time any Pin and Terminal C are shorted.
69
(5) Channel Select
Select the target channel of which control output volume and output mute are to be controlled.
(6) [Disable] button/ [Enable] button
Clicking the [Disable] button disables control from the Contact input, turning into [Enable] button.
Preset number of the controls performed before clicking the [Disable] button is retained, but both output
volume and output mute controls are cleared.
To control again, click the [Enable] button.
70
15.3. Function Assignment to the Contact Inputs
15.3.1. Preset memory change
[When in Direct mode]
Step 1. Set the Mode to [Direct] and Function to [Preset].
Step 2. Click the Parameter button, then select the Preset number from the pull-down menu.
[When in Binary mode]
Note: W
hen changing Preset in Binary mode, either output volume control or output mute control can be
assigned to other Pins.
When wishing to change 5 or more Presets using 4 Pins or when the necessary number of Pins cannot be
obtained because some Pins are occupied by other functions, the number of target Presets can be increased
using the less number of Pins when in binary mode.
Assign the necessary Pins to [Binary] mode depending on the number of Presets to use.
Pin number(s) in parenthesis is automatically selected.
Number of Presets to use
Presets 1 and 2
Presets 1 through 4
Presets 1 through 8
Presets 1 through 16
Pin to be selected for [Binary] mode
Pin 4
Pin 3, (4)
Pin 2, (3 and 4)
Pin 1, (2, 3, and 4)
71
15.3.2. Output volume control
Gives an offset value to the value set to the output attenuator.
Notes
• Output volume control can be performed only to the DP-SP3 unit targeted by the contact input.
• Group the output channels, then perform controls in groups.
• The channels belonging to the same group are equal in the obtained offset value but not in the output
attenuator value.
• It is not possible to assign the same channel to 2 or more groups.
• Control range is within the assignable value to output attenuator. (- ∞ to 0 dB)
• Even if the unit’s power is switched off, the given offset value can be effective when the power is switched on
again.
Assign the Volume Up or Volume Down function for a single group to the Pin.
Step 1. Set the function to [Volume Up] or [Volume Down].
Step 2. Select the parameter from the pull-down menu.
Step 3. Select the target channel to which the volume control function is assigned.
72
15.3.3. Output mute control
Assign the Mute ON/OFF function to the Pin.
Notes
• Output mute control is only available to the DP-SP3 unit targeted by the contact input.
• Group the output channels, then perform controls in groups.
• When “Pulse” is selected for the control method, even if the unit’s power is switched off, the output mute state
can be recalled when the power is switched on again.
• The output mute cannot be reset using the contact input for the channel of which output mute is set to ON with
the DP-SP3 PC Software.
Step 1. Set the mode to [Direct].
Step 2. Set the function to [Mute].
Step 3. Set the control to either [Make] or [Pulse].
Step 4. Select the target channel to which mute control function is assigned.
73
15.4. List of Functions Assignable to Pins
Functions assignable to Pins 1 through 4 are listed below.
Pin
1
2
3
4
C
All Pins set to Direct mode
Preset select / Volume adjustment / Mute
Preset select / Volume adjustment / Mute
Preset select / Volume adjustment / Mute
Preset select / Volume adjustment / Mute
COM
Pin
1
2
3
4
C
Pins 1 through 3 set to Direct mode
Volume adjustment / Mute
Volume adjustment / Mute
Volume adjustment / Mute
COM
Pin 4 set to Binary mode
Preset select
COM
Pin
1
2
3
4
C
Pins 1 and 2 set to Direct mode
Volume adjustment/Mute
Volume adjustment/Mute
COM
Pins 3 and 4 set to Binary mode
Preset select
Preset select
COM
Pin
1
2
3
4
C
Pin 1 set to Direct mode
Volume adjustment/Mute
COM
Pins 2 through 4 set to Binary mode
Preset select
Preset select
Preset select
COM
Pin
1
2
3
4
C
All Pins set to Binary mode
Preset select
Preset select
Preset select
Preset select
COM
74
URL: https://www.toa.jp/
201902
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF