TOA | RM-200MS | Specification Sheet | TOA RM-200MS Specification

TOA RM-200MS Specification
SYSTEM REMOTE MICROPHONE WITH
MONITORING OF MICROPHONE CAPSULE
RM-200MS
VM-RJA Unit*
For more easily connection between VM-2000
and RM-200MS.
Mountable on DIN rails, for cabinet rack
installation.
Dimension: 70mm x 40mm
The microphone capsule of the RM-200MS is monitored on
failure, and a failure control signal is provided to indicate a
failure on the microphone capsule. This function is required for
the remote microphone (for emergency purposes) to comply
with the EN 60849.
In case of a microphone capsule failure, the failure LED on the
VM-2000 and RM-200M(S) will illuminate. It is also possible to
control an extra LED for a separate failure indication
NOTE
*TheIMPORTANT
connection of the RM-200MS differs
from the RM-200M connection!
The RM-200MS must not be linked with the
standard RM-200M using the link connectors,
and must not be connected directly to the link
connector of the VM-2000.
SPECIFICATIONS
Model No.
RM-200MS
Remote Microphone
24 V DC (Operating range: 14 – 28 V DC)
Power input jack: Non-polarity type
Usable power input plug*2: Outer diameter ø5.5 mm,
inner diameter ø2.1 mm, length 9.5 mm
100 mA maximum
Current Consumption
Under 1%
Distortion
100 – 20,000 Hz
Frequency Response
Over 60 dB
Signal-to-Noise Ratio
0 dB*1, 600 Ω, balanced
Audio Output
Unidirectional electret condenser microphone
Microphone
Zones 1 – 5 or Zones 1 – 10 (2 stacked amplifiers connection),
Speaker Control
Groups 1 – 2, and All-Zone Broadcast
Activation of Emergency Broadcast (pre-recorded announcement*3 or live
Emergency Broadcast
microphone announcement) by Emergency Broadcast Switch
Activation of 5 messages*3
Voice Message Control
Microphone volume control
Volume Control
Connection Cable and Connector Category 5 STP cable, RJ45 connector
ABS resin, bluish gray
Finish
190 (W) × 76.5 (H) × 215 (D) mm
Dimensions
(Gooseneck microphone excluded)
790 g
Weight
Link cable (3m) …1
Accessory
Power Requirement
*1 0 dB = 1 V
*2 Use the AC adapter AD-4800 optionally available as our service component.
*3 An optional EV-200 Board must be mounted in the VM-2120 or VM-2240 Amplifier.
The voice messages must be pre-recorded into a CF (CompactFlash) card to be inserted into the EV-200 Board.
CONNECTONS
Using VM-RJA With Two RJ45 Connectors:
RM-200MS
VM-2000
RM-200MS
Any LINK connector of the VM-2000
and RM-200MS can be used.
remove jumpers
J1 & J2
RM-200MS
BU2
Using VM-RJA With One RJ45 Connector
And Screw Terminal:
Any LINK connector of the VM-2000 and
RM-200MS can be used. The numbers printed
next to the screw terminal on the VM-RJA board
correspond to the numbers of the RJ45 connectors.
1
2
3
4
5
6
7
8
S
KL1
pin 16
CONTROL I/O
KL2
15
16
BU1 VM
J1
J2
VM-RJA
pin 15
manufactured for TOA
Electronics Europe GmbH
J3
J4
RM-200MS
VM-2000
RM-200MS
remove jumpers
J1 & J2
wall inlet
RM-200MS
BU2
1
2
3
4
5
6
7
8
S
KL1
CONTROL I/O
KL2
15
16
BU1 VM
J1
J2
VM-RJA
pin 16
pin 15
manufactured for TOA
Electronics Europe GmbH
J3
J4
Connection Of An External Power Supply
RM-200MS
BU2
Remove the jumpers J3 and J4, and solder
the power supply's wires to the PCB as shown right.
The connection to the RM-200MS and VM-2000 are
as shown above.
KL1
1
2
3
4
5
6
7
8
S
J1
J2
VM-RJA
CONTROL I/O
KL2
15
16
BU1 VM
manufactured for TOA
Electronics Europe GmbH
J3
J4
+
_
TOA Corporation
URL : http://www.toa.jp/
Specifications are subject to change without notice.
Printed in Japan