zd TOA REMOTE MICROPHONE RM—1100(Q)
HDESCRIPTTON
The RM-1100 remote microphone can only be used for general-purpose public address applications. It
connects to the JP—034 Junction panel and can control up to ten individual zone broadcasts plus one
all-zone broadcast. For grouping, the DB—014 diode matrix board, which is installed in the JP—034
junction panel, must be added. When using two to five RM=1100s simultaneously priority order (individual
priority or first=in—first—out priority) can be established between units.
BSPECIFICATIONS
Power Requirements
24 V DC (supplied from the JP—-034 junction panel)
Current Consumption
150 mA
Output 0 dBV, 600 Q, balanced
Microphone Electret condenser microphone (with wind shield)
Aux Input —20 dBV, 100 kQ, unbalanced
Chime Activation of chime unit in the main system
/one Capacity
10 zones or 1 all-call zone
Number Of Cables
1 twin shielded cable and 20 cores
Total cable diameter must be under 14mm.
Color Gray
Dimensions 2/4 (W) X 62 (H) X 155 (D) mm (excluding microphone)
Weight 1.5 ka
Cable type—to—distance relationship
Distance 400 m or less
Power supply/contorol cables 0.65 mm
Shielded cable $0.26 mm
1200 m or less
01.2 mm
00.5 mM
800 m or less
0.90 mm
00.35 mm
BAPPEARANCE
— o o
Zó TOA REMOTE MICROPHONE BUSY INUSE
o
POWER
o
LL CALL CHIME
I 1
0
Side View Front View Side View
a
2/4
f )
O e
| seed еее [* o
U— J Bottom View
UNIT:mm SCALE: 1/4 Note: Numerical values in parentheses are for reference only.
960 DWG No: GRMOOMA1-1