TOA | VM-3240VA SA | Brochure | TOA VM-3240VA SA Quick start guide

TOA VM-3240VA SA Quick start guide
Integrated Voice Evacuation System
VM-3000 Series
SECURITY WITH CONVICTION
AT A GLANCE
Continuously TOA brings the knowledge gained from years of
experience in the development and production of sound and security
systems, which is reflected in the high reliability of many installations
worldwide.
• Cost-effective integrated public
address and voice evacuation system
The VM-3000 series is a cost-effective integrated public address
and voice alarm system engineered with powerful digital signal
processor (DSP). It is designed to fulfil the EN 54 European
regulation for voice alarm as well as the UL 2572 and
CAN/ULC-S576 certification, which complies with new
NFPA 72 code governing Mass Notification Systems. So the VM-3000
series not only ensures voice alarm in an emergency but also high
quality audio broadcasting.
• Easy installation and compact design
• EN 54 certified, UL 2572 and
CAN/ULC-S576 listed
• Intuitive and userfriendly configuration
through dedicated PC-Software
• Easy integration into existing building
management systems
• Convenient remote maintenance
saves time, effort and costs
The compact design enables the system to fit best in various small
to medium sized applications such as schools, shopping centres or
restaurants.
SYSTEM FEATURES
6 – 60 assignable speaker zones
240 – 3,600 watt, integrated system management amplifier
4 – 13 MIC/LINE audio inputs
(volume setting for each audio output)
8 remote microphones max. (4 x general + 4 x emergency;
EN 54: max. 2 x emergency or 4 x general + 1 x emergency)
2 selectable BGM audio inputs
C O M P A C T
&
R E L I A B L E
8 priority levels
1,000 system events can be logged
Maximum System Capacity
6 high quality electronic voice messages
LCD display of current status and configuration settings
Built-in emergency microphone
Simultaneous broadcast of 2 emergency messages
(alert and evacuation)
Remote maintenance via LAN
Continuous speaker line monitoring without interruption
of BGM or paging announcements (no external
amplifier required)
Modbus protocol ready
Complete fault detection and indication
EN 54-16 certified
Certificate No: 1438-CPD-0180
Output Power
3,600 W
Speaker Zones
60 zones
Remote Mic connection
8 units
N O R M
C O M P L I A N T
SYSTEM MANAGEMENT AMPLIFIER
VM-3240VA / VM-3360VA
&
S E C U R E
EXTENSION AMPLIFIER
VM-3240E / VM-3360E
1 unit per system
System management amplifier can be expanded by
2 models available: 240 W or 360 W power output
connecting up to 9 extension amplifiers
6 recorded general announcements and
2 models available: 240 W or 360 W
2 recorded emergency announcements
6 speaker line outputs
8 remote microphones max. (up to 4 emergency
8 control inputs and 8 control outputs for general purpose
remote microphones)
6 control inputs for emergency purpose and
6 zones selectable from the front panel
3 control outputs for status information
Built-in high quality electronic voice message
Connection to system management amplifier via VM Link
EMERGENCY REMOTE MICROPHONE
RM-300MF / RM-320F
REMOTE MICROPHONE
RM-200M / RM-210
Exclusively for broadcasts made by firemen in
11 function keys, 10 freely assignable
emergency situations
Zone, group and all-call paging, and activating
For activation of emergency mode, start and stop
pre-recorded messages
automatic broadcasts of emergency announcements,
Extraordinary clarity and freedom from distortion by
reset emergency signals and live microphone
built-in compression circuit
announcements
Up to 4 RM-200M per system management amplifier
CPU-switch for emergency broadcast to all zones
Up to 800 m total cable length
even in case of a CPU error
RM-210: Extension unit with 10 keys with similar
Up to 3 RM-320F extension units can be connected to
functions as the remote microphone
the emergency microphone
20 function buttons per extension unit
System software allows assigning of functions to the
individual keys
EMERGENCY POWER SUPPLY
VX-2000DS
Supplies the DC power to the system
Keeps the batteries charged
Ambient temperature controlled charging voltage
Automatically switch-over in case of AC mains failure
Matching battery: 2 x 12 V sealed lead batteries
SYSTEM AMPLIFIER
PILOT TONE DETECTION MODULE
VP-2241 (1 x 240 W)
VM-300SV
VP-2421 (1 x 420 W)
With built-in system amplifier input module VP-200VX
Speaker line failure can be detected with high accuracy
Module for transmission of status and audio signal
Module for installation between the speaker line end
between amplifier and control module
and the emergency input terminal
POWER SUPPLY UNIT
19" FRAME FOR VX-200PS
VX-200PS
VX-2000PF
To supply the power to VP system amplifiers
For rack mounting of up to 3 power supply units
SYSTEM EXAMPLES
RM-300MF
RM-200M
Fireman's
Microphone
Remote
Microphone
Zone 1
Audio Source
Zone 2
VM-3360VA (360W)
Voice Alarm System Amplifier
AC Mains
AC Adapter
Zone 3
VX-2000DS
Zone 4
Emergency
Power Supply
AC Mains
Zone 5
VX-200PS
Battery
Zone 6
VP-2421 External Amplifier
VP-2421 External Amplifier
Zone 7-12
AC Mains
VM-3360E (360W)
VM Extension Amplifier
Zone 13-18
VP-2421 External Amplifier
PM-660U
AC Mains
VM-3360E (360W)
Zone 19-24
AC Mains
VP-2241 External Amplifier
VM-3240E (240W)
RM LINK
VM LINK
Ext. PA LINK
DS LINK
DC Power
Specifications are subject to change without notice. (201908)833-61-348-0E
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising