FOR STAND-ALONE MODE
OPERATING INSTRUCTIONS
CONTROL INPUT UNIT
CONTROL OUTPUT UNIT
SX-2000CI
SX-2000CO
SX-2000CI
1
2
3
4
5
6
7
8
17
18
19
20
21
22
23
24
9
10
11
12
13
14
15
16
25
26
27
28
29
30
31
32
POWER
CPU OFF
FAULT
CONTROL INPUT
CONTROL INPUT UNIT SX-2000CI
SX-2000CO
1
2
3
4
5
6
7
8
17
18
19
20
21
22
23
24
9
10
11
12
13
14
15
16
25
26
27
28
29
30
31
32
POWER
CPU OFF
FAULT
CONTROL OUTPUT
CONTROL OUTPUT UNIT SX-2000CO
TABLE OF CONTENTS
1. SAFETY PRECAUTIONS ........................... 2
2. GENERAL DESCRIPTION ......................... 3
3. NOMENCLATURE AND FUNCTIONS
3.1. SX-2000CI Control Input Unit ............... 4
3.2. SX-2000CO Control Output Unit .......... 6
4. CONNECTIONS
4.1. Removable Terminal Plug
Connection ........................................... 8
4.2. Connection Example ............................ 9
4.3. Power Supply Connections ................ 10
4.4. Control Input Connections
(SX-2000CI Only) ............................... 14
4.5. Control Output Connections
(SX-2000CO Only) ............................. 14
4.6. CI/CO Link Terminal Connections ...... 15
5. SETTINGS
5.1. Stand-Alone Mode Setting ................. 15
5.2. Priority Control Settings of the Control
Inputs (SX-2000CI Only) .................... 16
6. SPECIFICATIONS
6.1. SX-2000CI Control Input Unit ............. 19
6.2. SX-2000CO Control Output Unit ........ 20
Note
Two modes of operation are made available for the SX-2000CI and SX-2000CO: Normal mode
where the unit operates within the SX-2000 system and Stand-alone mode where the unit
operates independently of the SX-2000 system.
This book provides instruction when the SX-2000CI and SX-2000CO are used in stand-alone
mode.
When using them in normal operation mode, refer to the instruction manual enclosed with the
SX-2000SM System Manager of the SX-2000 series.
Thank you for purchasing TOA's Control Input Unit and Control Output Unit.
Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.
1. SAFETY PRECAUTIONS
• Before installation or use, be sure to carefully read all the instructions in this section for correct and safe
operation.
• Be sure to follow all the precautionary instructions in this section, which contain important warnings and/or
cautions regarding safety.
• After reading, keep this manual handy for future reference.
Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property
damage which could result from mishandling. Before operating your product, read this manual first and
understand the safety symbols and messages so you are thoroughly aware of the potential safety hazards.
WARNING
Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.
CAUTION
Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.
WARNING
• Do not place cups, bowls, or other containers of
liquid or metallic objects on top of the unit. If they
accidentally spill into the unit, this may cause a fire
or electric shock.
When Installing the Unit
• Do not expose the unit to rain or an environment
where it may be splashed by water or other liquids,
as doing so may result in fire or electric shock.
• Use the unit only with the voltage specified on the
unit. Using a voltage higher than that which is
specified may result in fire or electric shock.
• Since the unit is designed for in-door use, do not
install it outdoors. If installed outdoors, the aging of
parts causes the unit to fall off, resulting in personal
injury. Also, when it gets wet with rain, there is a
danger of electric shock.
When the Unit is in Use
• Should the following irregularity be found during
use, immediately switch off the power, disconnect
the power supply plug from the AC outlet and
contact your nearest TOA dealer. Make no further
attempt to operate the unit in this condition as this
may cause fire or electric shock.
· If you detect smoke or a strange smell coming
from the unit.
· If water or any metallic object gets into the unit
· If the unit falls, or the unit case breaks
· If it is malfunctioning (no tone sounds.)
• To prevent a fire or electric shock, never open nor
remove the unit case as there are high voltage
components inside the unit. Refer all servicing to
qualified service personnel.
2
CAUTION
When Installing the Unit
• Avoid installing the unit in humid or dusty locations,
in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or
steam as doing otherwise may result in fire or
electric shock.
• SX-2000CI and SX-2000CO are designed
exclusively to be mounted in an equipment rack.
Be sure to follow the instructions below when rackmounting the unit. Failure to do so may cause a fire
or personal injury.
· Install the equipment rack on a stable, hard floor.
Fix it with anchor bolts or take other arrangements
to prevent it from falling down.
· When connecting the power cord of the DC
power supply panel for the SX-2000CI/CO to an
AC outlet, ensure that the total load current never
exceeds the AC outlet’s allowable current
capacity.
· The supplied rack-mounting screws can be used
for the TOA equipment rack only. Do not use
them for other racks.
When the Unit is in Use
• Use the specified DC power supply unit AD-011 or
AD-031B for the unit. Note that the use of other DC
power supply unit may cause a fire.
2. GENERAL DESCRIPTION
The SX-2000CI Control Input Unit is equipped with 32 control input channels, and the SX-2000CO Control
Output Unit with 32 control output channels, allowing various operations to be performed by connecting
external equipment.
One each of the SX-2000CI and SX-2000CO must be used in combination. Connecting the CI/CO link data
terminals of each unit to one another permits the contact data of multiple channels to be transmitted to the
remote locations with simple wiring.
The front-mounted indicators of each unit show the control input status or control output status.
The SX-2000CI and SX-2000CO are 1U-size* units that can be mounted in an EIA equipment rack. It has 2
power supply inputs, one of which can be connected to a backup power source to protect against power
failures. The SX-2000CI has a function to supply a stabilized 24 V DC.
Priority control of the control input can be performed by making settings at the SX-2000CI.
*1U size = 44.5 mm (standard size)
3
3. NOMENCLATURE AND FUNCTIONS
3.1. SX-2000CI Control Input Unit
[Front]
2
1
1
2
3
4
5
6
7
8
17
18
19
20
21
22
23
24
9
10
11
12
13
14
15
16
25
26
27
28
29
30
31
32
POWER
CPU OFF
FAULT
CONTROL INPUT
CONTROL INPUT UNIT SX-2000CI
3 4
Protective cover
Inside of the protective cover
USB
RUN
ID NUMBER RESET
ON
SETTING
45
23 6
CD
AB E
789
F01
5
6
7
8
1. Control Input Indicators
[CONTROL INPUT 1 – 32] (Green)
Light when the corresponding control inputs are
turned ON.
2. Power Indicator [POWER] (Blue)
Lights when the power is switched on.
3. CPU OFF Indicator [CPU OFF] (Red)
This indicator is not used.
4. FAULT Indicator [FAULT] (Yellow)
Lights when communications with the connected
SX-2000CO are interrupted.
5. USB Port [USB]
This port is not used.
6. RUN Indicator [RUN] (Green)
Normally flashes continuously.
7. ID Switch [ID NUMBER]
This switch is not used.
Always set to "0."
Note
This switch is set to "0" by default.
4
9
8. Reset Key [RESET]
Pressing this key restarts the SX-2000CI.
9. DIP Switch [SETTING]
• Switch 1
Sets operation mode. (See p. 15.)
ON: Operates in stand-alone mode.
OFF: Operates in normal mode.
• Switch 2
This switch is not used.
• Switches 3, 4
Perform priority control settings of the control
inputs by combined settings of Switches 3 and 4.
(See p. 16.)
• Switches 5 – 8
These switches are not used.
Note
Switches 1 – 8 are set to the OFF position by
default.
[Rear]
10
12
11
13
24
23
22
21
20
19
18
17
CONTROL
INPUT
14 15
8
7
6
5
4
3
2
16
1
CI/CO LINK
THROUGH DATA
DC 24V OUT
MAX. 0.1A
OFF
32
31
30
29
28
27
26
10. Functional Earth Terminal [SIGNAL GND]
Hum noise may be generated when external
equipment is connected to the unit. Connecting
this terminal to the functional earth terminal of
the external equipment may reduce the hum
noise.
Note: This terminal is not for protective earth.
11. DC Power Input Terminal [DC POWER IN]
Connect an optional AD-011 or AD-031B DC
Power Supply Panel to this terminal.
Select the appropriate panel taking into
consideration the total current consumption of all
equipment to be connected to the power supply
unit. (See p. 10.)
When not using a redundant power system*,
connect the [+] terminal of input A to the [+]
terminal of input B, and the [–] terminal of input A
to the [–] terminal of input B.
(See p. 11 and p. 13.)
* A method of connecting separate power
sources to each power input or connecting the
commercial power supply and backup power
supply separately to each power input to
prevent the system from going down when a
cable is broken or power fails.
25
16
15
14
13
12
11
10
ON
9
13. Control Input Terminals
[CONTROL INPUT 1 – 32]
Photo coupler inputs. A current of approximately
2 mA flows when shorted, and the voltage
becomes approximately 24 V DC when opened.
Activating the control input terminal causes the
control output terminal with the same channel
number (SX-2000CO) to close (provides make
contact).
14. CI/CO Link Through Switch [ON/OFF]
Normally, set this switch to the OFF position.
Note
This switch is set to "OFF" by default.
15. CI/CO Link Through Terminal
[CI/CO LINK THROUGH]
This terminal is not used.
Refer to the table below for the indicators'
functions and status.
16. CI/CO Link Data Terminal [CI/CO LINK DATA]
Connect this terminal to the CI/CO Link Terminal
of the SX-2000CO.
Refer to the table below for the indicators'
functions and status.
12. 24 V DC Output Terminal [DC 24 V OUT]
This terminal supplies 24 V DC, max. 100 mA to
connected external equipment.
[Indicators' functions and status of the CI/CO Link Through/Data terminals]
CI/CO LINK
THROUGH DATA
1
2
3
Functions
1. CI/CO LINK status
4
LED On or Flashing (green)
LED Off
Communication start
Communication stop
Communication start
Communication stop
LED On (orange)
2.
3. CI/CO LINK status
4. CI/CO LINK connection
confirmation
Unconnected
Connected
5
3.2. SX-2000CO Control Output Unit
[Front]
2
1
1
2
3
4
5
6
7
8
17
18
19
20
21
22
23
24
9
10
11
12
13
14
15
16
25
26
27
28
29
30
31
32
POWER
CPU OFF
FAULT
CONTROL OUTPUT
CONTROL OUTPUT UNIT SX-2000CO
3 4
Protective cover
Inside of the protective cover
USB
RUN
ID NUMBER RESET
ON
SETTING
45
23 6
CD
AB E
789
F01
5
6
7
8
1. Control Output Indicators
[CONTROL OUTPUT 1 – 32] (Green)
Light when the corresponding control outputs are
turned ON.
2. Power Indicator [POWER] (Blue)
Lights when the power is switched on.
3. CPU OFF Indicator [CPU OFF] (Red)
This indicator is not used.
4. FAULT Indicator [FAULT] (Yellow)
Lights when communications with the connected
SX-2000CI are interrupted.
5. USB Port [USB]
This port is not used.
6. RUN Indicator [RUN] (Green)
Normally flashes continuously.
6
9
7. ID Switch [ID NUMBER]
This switch is not used.
Always set to "1."
Note
This switch is set to "1" by default.
8. Reset Key [RESET]
Pressing this key restarts the SX-2000CO.
9. DIP Switch [SETTING]
• Switch 1
Sets operation mode. (See p. 15.)
ON: Operates in stand-alone mode.
OFF: Operates in normal mode.
• Switches 2 – 8
These switches are not used.
Note
Switches 1 – 8 are set to the OFF position by
default.
[Rear]
10
12
11
24
23
22
21
20
19
18
17
13 14
8
7
6
5
4
3
2
1
CONTROL
OUTPUT
C NC NO
OFF
32
31
30
29
28
27
26
10. Functional Earth Terminal [SIGNAL GND]
Hum noise may be generated when external
equipment is connected to the unit. Connecting
this terminal to the functional earth terminal of
the external equipment may reduce the hum
noise.
Note: This terminal is not for protective earth.
11. DC Power Input Terminal [DC POWER IN]
Connect an optional AD-011 or AD-031B DC
Power Supply Panel to this terminal.
Select the appropriate panel taking into
consideration the total current consumption of all
equipment to be connected to the power supply
unit. (See p. 10.)
When not using a redundant power system*,
connect the [+] terminal of input A to the [+]
terminal of input B, and the [–] terminal of input A
to the [–] terminal of input B.
(See p. 11 and p. 13.)
When driving the unit with the power supply unit
connected to the SX-2000CI, connect the power
supply to this terminal via an optional RM-200RJ
Terminal Unit.
(See p. 12 and p. 13.)
* A method of connecting separate power
sources to each power input or connecting the
commercial power supply and backup power
supply separately to each power input to
prevent the system from going down when a
cable is broken or power fails.
25
16
15
14
13
12
11
10
15
CI/CO LINK
THROUGH DATA
ON
9
12. Control Output Terminals
[CONTROL OUTPUT 1 – 32]
Relay make contact outputs.
Activating the control input terminal of the SX2000CI causes the control output terminal with
the same channel number to close.
Each contact capacity is rated at 40 V DC for
withstand voltage, and 2 mA – 300 mA for
control current.
13. CI/CO Link Through Switch [ON/OFF]
Normally, set this switch to the OFF position.
Note
This switch is set to "OFF" by default.
14. CI/CO Link Through Terminal
[CI/CO LINK THROUGH]
This terminal is not used.
Refer to the table below for the indicators'
functions and status.
15. CI/CO Link Data Terminal [CI/CO LINK DATA]
Connect this terminal to the CI/CO Link Terminal
of the SX-2000CI.
Power to operate the unit cannot be supplied
through this terminal.
Refer to the table below for the indicators'
functions and status.
[Indicators' functions and status of the CI/CO Link Through/Data terminals]
CI/CO LINK
THROUGH DATA
1
2
3
Functions
1. CI/CO LINK status
4
LED On or Flashing (green)
LED Off
Communication start
Communication stop
Communication start
Communication stop
LED On (orange)
2.
3. CI/CO LINK status
4. CI/CO LINK connection
confirmation
Unconnected
Connected
7
4. CONNECTIONS
4.1. Removable Terminal Plug Connection
Model Number
a
AI 0,34-8 TQ
AI 0,5-8 WH
b
l1
b
a
Notes
• Do not use a micro screwdriver. Sufficient torque is not given to the screws when tightening them, and
connections may not be secured.
• Avoid soldering stranded or shielded cable, as contact resistance may increase when the cable is tightened
and the solder is crushed, possibly resulting in an excessive rise in joint temperatures.
• When connecting 2 cables or a shielded cable to a single terminal,
use a ferrule terminal with an insulation sleeve to crimp the cables
because such cable conductors could become loose.
Recommended ferrule terminals for signal cables
Insulation sleeve
Contact section
(made by Phoenix Contact)
l2
2 mm 0.8 mm 12.5 mm 8 mm
2.5 mm 1.1 mm
l2
14 mm 8 mm
l1
Recommended ferrule terminals for power supply cables
(made by Phoenix Contact)
a1
a2
b
3.4 mm
AI-TWIN 2 x 1,5-8 BK
l1
l2
Insulation sleeve
Contact section
b
AI 1,5-8 BK
a
a1
Model Number
1.8 mm 14 mm 8 mm
6.6 mm 3.6 mm 2.3 mm 16 mm 8 mm
a2
Crimping tool: CRIMPFOX UD6-4 (made by Phoenix Contact)
l2
l1
Cable sheath to trim
Solid cable and stranded cable
Shielded cable
7 mm*
7 mm*
* Expose 8 mm or more when using the
above ferrule terminal, and cut off an extra
conductor protruding from the sleeve.
15 mm
Wiring procedures
Procedures below are for the removable terminal plug with fixing screws.
Step 1. Wiring the supplied removable terminal plug.
Straight slot screwdriver
To tighten
To loosen
1-1. Loosen the terminal screws to insert the wire.
1-2. Tighten the terminal screws.
Ensure that the wire does not break free
when pulled. If the wire does pull free, repeat
the connection procedure from the start.
Removable terminal plug
Terminal screw
Step 2. Insert the wired terminal plug into the
corresponding terminal block in the unit's rear
panel.
Step 3. Tighten the fixing screw.
Fixing screw
Notes
• Do not reverse Steps 1 and 2 above. Force is applied to the connected receptacle pins while tightening the
terminal screw and they may be damaged, resulting in bad connector contact.
• When detaching the terminal plug, pull it straight out. Pulling it out at an angle may cause the terminal plug
or terminal block to break.
8
4.2. Connection Example
There are 4 connection configurations depending on the DC power supply and CI/CO link connections.
Note: For the detailed information on the connections of power supply unit and CI/CO links, refer to the page
indicated at the end of each "Connection example."
4.2.1. Connection example 1
Connect each 2 power supply units to the SX-2000CI and SX-2000CO separately. (See p. 10 and 15.)
Program timer
SX-2000CI
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Power supply unit (1)
POWER
CPU OFF
FAULT
CONTROL INPUT
CONTROL INPUT UNIT SX-2000CI
Redundant power supply system*
SX-2000CO
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Power supply unit (2)
Digital announce machine
POWER
CPU OFF
FAULT
CONTROL OUTPUT
CONTROL OUTPUT UNIT SX-2000CO
Power supply unit (3)
* A method of connecting separate power sources to each power
input or connecting the commercial power supply and backup
power supply separately to each power input to prevent the
system from going down when a cable is broken or power fails.
Power supply unit (4)
4.2.1. Connection example 2
Connect each one power supply unit to the SX-2000CI and SX-2000CO separately. (See p. 11 and 15.)
SX-2000CI
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Program timer
POWER
CPU OFF
FAULT
CONTROL INPUT
CONTROL INPUT UNIT SX-2000CI
Power supply unit (1)
SX-2000CO
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Digital announce machine
POWER
CPU OFF
FAULT
CONTROL OUTPUT
CONTROL OUTPUT UNIT SX-2000CO
Power supply unit (2)
4.2.1. Connection example 3
Connect 2 power supply units to the SX-2000CI only via Terminal unit. (See p. 11.)
SX-2000CI
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Program timer
POWER
CPU OFF
FAULT
CONTROL INPUT
CONTROL INPUT UNIT SX-2000CI
Terminal unit
Power supply unit (1)
Supplies power from
the SX-2000CI side
Redundant power
supply system
Terminal unit
Power supply unit (2)
SX-2000CO
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Digital announce machine
POWER
CPU OFF
FAULT
CONTROL OUTPUT
CONTROL OUTPUT UNIT SX-2000CO
4.2.1. Connection example 4
Connect a single power supply unit to the SX-2000CI only via Terminal unit. (See p. 13.)
SX-2000CI
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Program timer
POWER
CPU OFF
FAULT
CONTROL INPUT
CONTROL INPUT UNIT SX-2000CI
Terminal unit
Power supply unit
Supplies power from
the SX-2000CI side
Terminal unit
SX-2000CO
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Digital announce machine
POWER
CPU OFF
FAULT
CONTROL OUTPUT
CONTROL OUTPUT UNIT SX-2000CO
: CI/CO link
: Power cable
: CPEV cable
: Control line
9
4.3. Power Supply Connections
Use an optional AD-011 or AD-031B DC Power Supply Panel to this terminal. Select the appropriate panel
taking into consideration the total current consumption of all equipment to be connected to the power supply
unit.
4.3.1. Connection for Example 1
Connect each 2 power supply units to the SX-2000CI and SX-2000CO separately as follows. Connect one
power supply unit to A channel of the DC power input terminal and the other power supply unit to the B
channel of the DC power input terminal on the SX-2000CI. Connect the power supply units to the SX-2000CO
in the same manner.
Even if one of the 2 units fails or its power supply line is broken, power is still supplied from the other unit,
preventing the system from going down.
AD-011 DC power supply panel
SX-2000CI
24
23
22
21
20
19
18
17
CONTROL
INPUT
8
7
6
5
4
3
2
1
CI/CO LINK
THROUGH DATA
DC 24V OUT
MAX. 0.1A
OFF
32
24VDC OUT
31
30
29
28
27
26
25
16
15
14
13
12
11
10
ON
9
24VDC IN
DC power input terminal
Cable: AWG14 – 18
AD-011
4P removable terminal plug
(supplied with the SX-2000CI)
24VDC OUT
24VDC IN
STP Category 5 straight cable
(with RJ45 connectors)
Cable: AWG14 – 18
SX-2000CO
AD-011
24
23
22
21
20
19
18
17
8
7
6
5
4
3
2
1
CONTROL
OUTPUT
C NC NO
OFF
32
24VDC OUT
31
30
29
28
27
26
25
16
15
14
13
12
11
10
CI/CO LINK
THROUGH DATA
ON
9
24VDC IN
DC power input terminal
Cable: AWG14 – 18
AD-011
4P removable terminal plug
(supplied with the SX-2000CO)
24VDC OUT
24VDC IN
Cable: AWG14 – 18
Note: When using the AD-031B DC power supply panel (optional), make connections in the same manner.
10
4.3.2. Connection for Example 2
Supply the power from each one power supply panel to the SX-2000CI and SX-2000CO separately.
Connect the (+) terminal of channel A to the (+) terminal of channel B, and the (–) terminal of channel A to the
(–) terminal of channel B.
AD-011 DC power supply panel
SX-2000CI
24
23
22
21
20
19
18
17
CONTROL
INPUT
8
7
6
5
4
3
2
1
CI/CO LINK
THROUGH DATA
DC 24V OUT
MAX. 0.1A
OFF
32
24VDC OUT
31
30
29
28
27
26
25
16
15
14
13
12
11
10
ON
9
24VDC IN
DC power input terminal
STP Category 5 straight cable
(with RJ45 connectors)
Cable: AWG14 – 18
4P removable terminal plug
(supplied with the SX-2000CI)
Note
Use a ferrule terminal when connecting
2 cables to a single terminal. (See p. 8.)
SX-2000CO
AD-011
24
23
22
21
20
19
18
17
8
7
6
5
4
3
2
1
CONTROL
OUTPUT
C NC NO
OFF
32
24VDC OUT
31
30
29
28
27
26
25
16
15
14
13
12
11
10
CI/CO LINK
THROUGH DATA
ON
9
24VDC IN
DC power input terminal
Cable: AWG14 – 18
4P removable terminal plug
(supplied with the SX-2000CO)
Note: When using the AD-031B DC power supply panel (optional), make connections in the same manner.
4.3.3. Connection for Example 3
Both the SX-2000CI and SX-2000CO can be driven by connecting 2 power supply panels to the SX-2000CI
only.
Connect the DC power input terminals of the SX-2000CI to those of the SX-2000CO and the CI/CO link data
terminals of the SX-2000CI to those of the SX-2000CO via the RM-200RJ Terminal Unit (optional).
(See the next page.)
When installing the SX-2000CI and SX-2000CO separately from each other, the power supply panel does not
need to have at each unit by making connection in this manner.
Note
When connecting the power supply panel to one of the equipment, be sure to connect it to the SX-2000CI
side.
If it is connected to the SX-2000CO side, the maximum cable length between the SX-2000CI and SX-2000CO
may be reduced.
[Maximum cable length]
The maximum cable length between the SX-2000CI and SX-2000CO varies depending on the conductor
diameter of the CPEV cable used between the RM-200RJs.
The following table shows the conductor diameter of the CPEV cable vs. maximum cable length when the
power is supplied from the SX-2000CI side.
Conductor diameter
Maximum cable length
AWG 22
160 m
AWG 19
320 m
AWG 16
570 m
AWG 19 x 3 pair-CPEV (2 pairs for DC and 1 pair for data)
640 m
AWG 16 x 3 pair-CPEV (2 pairs for DC and 1 pair for data)
800 m
11
[Connections]
It is recommended to use an optional RM-200RJ Terminal Unit that serves wiring conversion between the
CPEV cable and STP Category 5 straight cable (with RJ45 connectors). Connect the CPEV cable between
the same terminals of both RM-200RJ units pairing cables 3 with 6, 4 with 5, and 7 with 8 as shown below.
Terminals 4 and 5 serve to supply power to B channel.
SX-2000CO
CI/CO link
data terminal
RM-200RJ
terminal unit
Note
Terminals 1 and 2
cannot be used for
power supply line.
DC power
input terminal
AWG14 – 18
4
5
4
5
3
6
7
STP Category 5 straight cable
(with RJ45 connectors)
8
Shield
7
8
AWG14 – 18
SX-2000CI
CI/CO link
data terminal
RM-200RJ
Over 3-pair shielded
CPEV cable (main cable)
DC power
input terminal
AWG14 – 18
4
5
4
5
3
6
7
STP Category 5 straight cable
(with RJ45 connectors)
7
8
Shield
8
AD-011
DC power supply panel
24VDC OUT
Note: The RM-200RJ can be installed on a desk or to a wall.
24VDC IN
[RM-200RJ Mounting dimensions]
84
75
24VDC IN
12
Note: When using the AD-031B DC power supply panel (optional),
make connections in the same manner.
13.5
44.5
AWG14 – 18
116
24VDC OUT
44.5
AD-011
Unit: mm
4.3.4. Connection for Example 4
Drive both the SX-2000CI and SX-2000CO by connecting a single power supply panel to the SX-2000CI only.
Connect the DC power input terminals of the SX-2000CI to those of the SX-2000CO and the CI/CO link data
terminals of the SX-2000CI to those of the SX-2000CO via the RM-200RJ Terminal Unit (optional).
When installing the SX-2000CI and SX-2000CO separately from each other, the power supply panel does not
need to have at each unit by making connection in this manner.
Note
When connecting the power supply unit to one of the equipment, be sure to connect it to the SX-2000CI side.
If it is connected to the SX-2000CO side, the maximum cable length between the SX-2000CI and SX-2000CO
may be reduced.
For the conductor diameter of the CPEV cable vs. maximum cable length when the power is supplied from the
SX-2000CI side, refer to the table on p. 11.
[Connections]
It is recommended to use an optional RM-200RJ Terminal Unit that serves wiring conversion between the
CPEV cable and STP Category 5 straight cable (with RJ45 connectors). Connect the CPEV cable between
the same terminals of both RM-200RJ units pairing cables 3 with 6, and 7 with 8 as shown below.
SX-2000CO
RM-200RJ terminal unit
CI/CO link
data terminal
DC power
input terminal
3
6
7
STP Category 5 straight cable
(with RJ45 connectors)
8
Shield
7
8
AWG14 – 18
SX-2000CI
CI/CO link
data terminal
DC power
input terminal
STP Category 5 straight cable
(with RJ45 connectors)
RM-200RJ
Over 2-pair shielded
CPEV cable
(main cable)
3
6
7
AWG14 – 18
8
7
Shield
8
AD-011 DC power supply panel
24VDC OUT
24VDC IN
AWG14 – 18
Notes
• The RM-200RJ can be installed on a desk or to a wall.
Refer to the RM-200RJ mounting dimensions on the
previous page.
• When using the AD-031B DC power supply panel
(optional), make connections in the same manner.
13
4.4. Control Input Connections (SX-2000CI Only)
This connection example allows timer-activated automatic broadcasts.
When the TT-104B's preprogrammed time is reached, the SX-2000CI receives a control output signal (make
contact) from the TT-104B and activates preset broadcast patterns.
TT-104B
program timer
OUTPUT CHANNEL (24 V DC 0.5 A)
OUTPUT CHANNEL (24 V DC 0.5 A)
CAUTION
ON
ON
BE SURE TO SET
THIS SWITCH TO “ON”
AFTER INSTALLATION
OFF
OFF
MEMORY CHANNEL
BACK UP ASSIGNMENT
Cable: AWG22 – 28
twisted pair cable
SX-2000CI
24
23
22
21
20
19
18
17
CONTROL
INPUT
8
7
6
5
4
3
2
1
CI/CO LINK
THROUGH DATA
DC 24V OUT
MAX. 0.1A
OFF
32
31
30
29
28
27
26
25
16
15
14
13
12
11
10
ON
9
Open voltage: 24 V DC
Short-circuit current: 2 mA
16P removable terminal plug
(supplied with the SX-2000CI)
Control input terminals
4.5. Control Output Connections (SX-2000CO Only)
This example shows the connection method to remotely activate the external sound source equipment.
When a broadcast is started, the SX-2000CO provides a make contact to activate the EV-350R.
Control output terminals
SX-2000CO
24
23
22
21
20
19
18
17
8
7
6
5
4
3
2
1
CONTROL
OUTPUT
C NC NO
OFF
32
31
30
29
28
27
26
25
16
15
14
13
12
11
10
ON
9
Cable: AWG22 – 28
twisted pair cable
Withstand voltage: 40 V DC
Control current: 2 – 300mA
Activation control input terminal 1
EV-350R
Digital announcer
CI/CO LINK
THROUGH DATA
COM terminal
6P removable terminal plug
(supplied with the SX-2000CO)
OUTPUT
AUX INPUT
UNBAL.
UNBAL.
Activation control input terminal 2
14
4.6. CI/CO Link Terminal Connections (Applies to the example 1 or 2 on p. 9.)
Connect the same CI/CO link data terminals of both the SX-2000CI and SX-2000CO.
For the connection cable, use a STP Category 5 twisted pair cable (with RJ45 connectors).
CI/CO link data terminal
SX-2000CI
24
23
22
21
20
19
18
17
CONTROL
INPUT
8
7
6
5
4
3
2
STP Category 5 straight cable
(with RJ45 connectors)
CI/CO LINK
THROUGH DATA
1
CI/CO LINK
THROUGH DATA
DC 24V OUT
MAX. 0.1A
OFF
32
31
30
29
28
27
26
25
16
15
14
13
12
11
10
ON
9
OFF
ON
CI/CO link through switch: OFF
(Factory preset: OFF)
CI/CO link data terminal
SX-2000CO
24
23
22
21
20
19
18
17
8
7
6
5
4
3
2
32
31
30
29
28
27
26
25
16
15
14
13
12
11
10
CI/CO LINK
THROUGH DATA
1
CONTROL
OUTPUT
C NC NO
OFF
OFF
CI/CO LINK
THROUGH DATA
ON
9
ON
CI/CO link through switch: OFF
(Factory preset: OFF)
The SX-2000CI and SX-2000CO can be connected using the shielded CPEV cable (1-pair for data line) via
the optional RM-200RJ Terminal unit.
Note
Total cable length connecting CI/CO link terminals within the system must be kept shorter than 800 m.
5. SETTINGS
5.1. Stand-Alone Mode Setting
Inside of the protective cover
SX-2000CI
USB
RUN
ID NUMBER RESET
ON
SETTING
45
23 6
CD
AB E
789
F01
Screw
Protective cover
Reset key
DIP switches
Note: Fragmentary view of the SX-2000CI. This view is the same for the SX-2000CO.
Step 1. Remove the protective cover on the SX-2000CI/CO's front panel by
unscrewing it with a Phillips screwdriver.
ON
SETTING
Step 2. Set the DIP switch 1 on the SX-2000CI/CO to ON.
Note: Switch 1 is set to OFF by default.
15
Step 3. Set the link through switch on the SX-2000CI/CO's rear panel to the OFF position.
Note: The CI/CO link through switch is set to OFF by default.
SX-2000CI rear
24
23
22
21
20
19
18
17
CONTROL
INPUT
8
7
6
5
4
3
2
CI/CO LINK
THROUGH DATA
1
CI/CO LINK
THROUGH DATA
DC 24V OUT
MAX. 0.1A
OFF
32
31
30
29
28
27
26
25
16
15
14
13
12
11
10
ON
9
OFF
ON
CI/CO link through switch: OFF
Note: Fragmentary view of the SX-2000CI. This view is the same for the SX-2000CO.
RESET
Step 4. Press the Reset key on the SX-2000CI/CO's front panel.
The SX-2000CI/CO is reactivated.
Step 5. Replace the protective cover.
Note
When operating the SX-2000CI/CO in stand-alone mode, do not connect it to the SX-2000AO or SX-2100AO
as doing so may cause system malfunction.
5.2. Priority Control Settings of the Control Inputs (SX-2000CI Only)
Priority control of the control inputs can be performed by combined settings of the DIP switches 3 and 4 inside
the protective cover (see the previous page) on the SX-2000CI's front panel.
Type of priority control
DIP switch 3
DIP switch 4
Figure of the DIP switch
ON
No priority control
(factory default)
OFF
ON
P. 17
OFF
P. 17
ON
SETTING
ON
P. 18
ON
First-in-first-out
SETTING
OFF
ON
Last-in-first-out
SETTING
OFF
ON
Terminal numberbased priority
ON
Reference page
SETTING
P. 18
Notes
• If you change the DIP switch setting, be sure to press the Reset key inside the protective cover to restart the
SX-2000CI.
• Control inputs act as such that they have been closed in numerical order of terminal numbers after the SX2000CI is switched on or restarted with these inputs closed in any order.
In this case, the highest priority is assigned to the control input of the largest terminal number when the
priority control type is "Last-in-first-out," and to the control input of the smallest terminal number when "Firstin-first-out."
16
5.2.1. No priority control (DIP switch 3: OFF, DIP switch 4: OFF)
In this mode, priority control is disabled. (Factory default)
For example, closing the control input 2 while the control input 1 is closed causes
the control output 2 to close simultaneously while the control output 1 remains
closed.
Control inputs 3 – 32 operate in the same manner.
ON
SETTING
Closed (make contact)
Open (break contact)
Control input 1
Closed
Open
Control input 2
Closed
Open
Control output 1
Closed
Open
Control output 2
5.2.2. Terminal number-based priority (DIP switch 3: ON, DIP switch 4: OFF)
The smaller the terminal number of the control input, the higher the priority level.
For example, closing the control input 1 while the control input 2 is closed causes
the control output 2 to open.
Opening the control input 1 causes the control output 2 to close.
Control inputs 3 - 32 operate in the same manner. Latency of 100 ms is employed
in order to prevent two or more control outputs from turning ON.
ON
SETTING
Closed
Open
Control input 1
Closed
Control input 2
Closed
Open
Control output 1
Closed
Closed
Open
Control output 2
100 ms
100 ms
Control input 2 is disabled while the control input 1 is being closed. The control output 2 becomes closed
when the control input 1 is opened.
Closed
Open
Control input 1
Closed
Control input 2
Closed
Open
Control output 1
Closed
Control output 2
100 ms
17
5.2.3. Last-in-first-out (DIP switch 3: OFF, DIP switch 4: ON)
The most recent control input takes precedence over the earlier one.
For example, closing the control input 2 while the control input 1 is closed causes
the control output 1 to open. The control output 1 becomes closed when the control
input 2 is opened.
Control inputs 3 - 32 operate in the same manner. Latency of 100 ms is employed
in order to prevent two or more control outputs from turning ON.
ON
SETTING
ON
SETTING
Closed
Control input 1
Closed
Open
Control input 2
Closed
Closed
Open
Control output 1
Closed
Open
Control output 2
100 ms
100 ms
5.2.4. First-in-first-out (DIP switch 3: ON, DIP switch 4: ON)
The first control input takes precedence over the later control output.
For example, the control output 2 is not closed while the control input 1 is being
closed.
The control output 2 becomes closed when the control input 1 is opened.
Control inputs 3 - 32 operate in the same manner.
Latency of 100 ms is employed in order to prevent two or more control outputs from
turning ON.
Closed
Open
Control input 1
Closed
Control input 2
Closed
Open
Control output
Closed
Control outpu2
100 ms
18
6 SPECIFICATIONS
6.1. SX-2000CI Control Input Unit
Power Source
Current Consumption
Indication
Control Input
Priority Control
CI/CO Link
Connector
Connection Cable
Maximum Cable Distance
Applicable power supply: AD-011, AD-031B
24 V DC (operational range: 20 – 40 V DC), redundant power supply enabled
using 2 channels of DC inputs
Under 0.7 A (maximum value in the power operating range)
Under 0.55 A (at 24 V DC operation)
Power indicator, Control input indicators (32), CPU-OFF indicator,
FAULT indicator
32 inputs, no-voltage make contacts, open voltage: 24 V DC,
short-circuit current: 2 mA, photo coupler inputs,
removable terminal blocks (16P)
No priority control, Terminal number-based priority, Last-in-first-out priority,
First-in-first-out priority
RJ45 connector
Main cable:
Shielded CPEV cable* or STP Category 5 straight cable
* When connecting the power supply to each unit: 1-pair for data line
When connecting the power supply only to the SX-2000CI:
1-pair data line and 2-pair power line for a redundant power supply
system, or 1-pair data line and 1-pair power line for a non-redundant
power supply system
Branch cable: STP Category 5 straight cable
800 m
Maximum Delay Time
24 V DC Output section
Connector
Maximum Feeing Current
Output Voltage
300 ms
Operating Temperature
Operating Humidity
Finish
0 – 40 °C
35 – 80% RH (no condensation)
Panel: Aluminum, black, anodized aluminum
Case: Surface-treated steel sheet
482 (w) x 44 (h) x 331.5 (d) mm
3.6 kg
Dimensions
Weight
Removable terminal block (2P)
100 mA
24 V DC within ±10%
Note: The design and specifications are subject to change without notice for improvement.
• Accessories
Removable terminal plug (16 pins) ............ 4
Removable terminal plug (4 pins) .............. 1
Removable terminal plug (2 pins) .............. 1
Rack mounting screw
with plain washer (5 x 12) .......................... 4
• Optional products
DC power supply panel: AD-011, AD-031B
Terminal unit:
RM-200RJ
19
6.2. SX-2000CO Control Output Unit
Power Source
Current Consumption
Indication
Control Output
CI/CO Link
Connector
Connection Cable
Maximum Cable Distance
Maximum Delay Time
Operating Temperature
Operating Humidity
Finish
Dimensions
Weight
Applicable power supply: AD-011, AD-031B
24 V DC (operational range: 20 – 40 V DC), redundant power supply enabled
using 2 channels of DC inputs
Under 0.34 A (maximum value in the power operating range)
Under 0.29 A (at 24 V DC operation)
Power indicator, Control output indicators (32), CPU-OFF indicator,
FAULT indicator
32 outputs, no-voltage make contacts, relay contact outputs (withstand
voltage: 40 V DC, control current: 2 – 300 mA),
removable terminal blocks (6P)
RJ45 connector
Main cable:
Shielded CPEV cable* or STP Category 5 straight cable
* When connecting the power supply to each unit: 1-pair for data line
When connecting the power supply only to the SX-2000CI:
1-pair data line and 2-pair power line for a redundant power supply
system, or 1-pair data line and 1-pair power line for a non-redundant
power supply system
Branch cable: STP Category 5 straight cable
800 m
300 ms
0 – 40 °C
35 – 80% RH (no condensation)
Panel: Aluminum, black, anodized aluminum
Case: Surface-treated steel sheet
482 (w) x 44 (h) x 331.5 (d) mm
3.6 kg
Note: The design and specifications are subject to change without notice for improvement.
• Accessories
Removable terminal plug (6 pins) ............ 16
Removable terminal plug (4 pins) .............. 1
Rack mounting screw
with plain washer (5 x 12) .......................... 4
• Optional products
DC power supply panel: AD-011, AD-031B
Terminal unit:
RM-200RJ
Warning
This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may
cause radio interference.
Traceability Information for Europe
Manufacturer:
TOA Corporation
7-2-1, Minatojima-Nakamachi, Chuo-ku, Kobe, Hyogo,
Japan
Authorized representative:
TOA Electronics Europe GmbH
Suederstrasse 282, 20537 Hamburg,
Germany
URL: http://www.toa.jp/
133-02-00319-00

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement