PRECAUTIONS FOR USE OF THE INFRARED CONFERENCE UNIT
Depending on production date, 2 versions of Infrared conference units (TS-901/902/801/802) that differ in
specification are used in the Infrared Conference system, even though they have identical model numbers.
Since setting methods and other points may differ in part between the 2 versions (having the same model
number), please keep the following instructions in mind when using the Conference units.
1. Identifying Units Based on TOA Logo Position
[If the TOA logo is located on the right]
[If the TOA logo is located on the left]
TS-910/800 Series instruction manual descriptions
are not applicable in terms of the operations
described in the following sections.
Please use the unit as described in the TS-910/800
Series instruction manual.
Top view of the Conference unit
Top view of the Conference unit
2. Setup and Operation of Units Having the TOA Logo on the Right
Units with right-side logos differ from units with left-side logos in the following specific areas:
2.1. Unit number settings
The usable unit number is limited.
Using the Unit address number setting switch located at the bottom
of the unit, set the unit number within the range shown in the following
table. The unit will not operate if its assigned number is not within the
valid range.
Model No.
TS-901 and TS-902
TS-801 and TS-802
Usable Unit Number Range
01 – 96 (00 when used only for monitoring)
01 – 64 (00 when used only for monitoring)
Inside cover
Bottom of
Conference unit
Unit address number
setting switch
(Setting switch label
shown in the figure.)
10
UNIT ID
1
2.2. Fixed PTT priority speech operation (TS-901 and TS-801 only)
Priority speech key
These models have no Priority speech key operation setting switch.
The Priority speech key is physically limited to PTT operation,
therefore priority speech can only be enabled while the Priority
speech key is held down.
Speech only possible
while key is held down.
2.3. Monitor volume adjustment
The Monitor volume control is only located on the right side of the
base of the unit.
The sound output of headphone terminals located on both sides of
the unit and the monitor speaker can be simultaneously adjusted
with this Monitor volume control.
Monitor volume control
HEADPHONES
MAIN SUB
POWER
HEADPHONES
MAIN SUB
ON
OFF
Right side of Conference unit
URL: http://www.toa.jp/
133-07-00011-01
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising