TOA | VX-030DA | Brochure | TOA VX-015DA Quick start guide

TOA VX-015DA Quick start guide
Voice Alarm System
VX-3000 Series
Combined highly integrated voice alarm
and public address system
VX-3000 series
Highly Integrated Voice Alarm & Public Address System
The issue of security is more than ever important. Our VX-3000 is a reliable and energy-saving voice alarm system that
combines all important functions for PA/VA in one unit frame. The limited number of components makes the design and
installation much easier, as well as saving space and reducing cable complexity. This enables rapid system configuration and
makes the VX-3000 a cost effective system.
It comes with low loss modular class D amplifiers, with 3 different output ratings. These can easily be removed or replaced
simply by unplugging them; there is no need for specialist tools. By using low loss modular class D amplifiers and modern
power supply switching technology the system becomes much more energy efficient and keeps the operating costs low.
Thanks to its flexible and scalable system architecture the VX-3000 system can be used for both small and large applications,
with up to 320 remote microphones and 160 audio sources.
Light-weight: Modern supply switching technology and digital amplifiers
Energy saving: Standby mode for low power consumption during battery backup reduces the required battery capacity
Reliable: Advanced failure detection& indication
DSP functions: Comp., SPEQ, FBS and Ambient Noise Control (ANC)
Integration: Connectable with TOA’s other system; NX-300 and IP-3000 Series
Remote control: Remote protocol enables VX-3000 to be controlled by external devices. Furthermore VX-3000 complies with Modbus protocol
System Component
Cost Effective / Space saving
Remote Microphone
Amplifier
All important functions for PA/VE are incorporated in
one unit frame.
Minimum Components
RM-200SF
RM-320F
RM-300X
RM-210F
Frames
VX-3004F
VX-3008F
VX-015DA / VX-030DA / VX-050DA
Power Supply
VX-3016F
VX-3000DS
Decentralized
IP Network based, hub-less and the ring topology.
Network
Network
Extreme Flexibility
VX-3004F
The underlying frames of the system are selectable according
to the required
BGM VX-3004F
AMP broadcast pattern.
BGM
matrix
BGM
BGM
BGM
BGM VX-3004F
Requirements
The floor is divided into four zones.
Each zone needs individual background music
Announcement is sent to selected zone(s)
Background music is overrode by announcement
BGM
matrix
BGM
BGM
BGM
BGM
VX-3004F
Up to 4 modular amplifiers mountable
Multi-route architecture
Each zone has an exclusive amplifier
One of mounted amplifiers can serve as a standby amplifier
matrix
BGM
AMP
AMP
AMP
AMP
AMP
AMP
AMP
AMP
AMP
AMP
AMP
VX-3008F
Requirements
The floor is composed of multiple zones.
Common background music is delivered to all zones
Announcement is sent to selected zone(s) without disrupting
the background music in the other zones.
Background music is overrode by announcement
VX-3008F
Up to 3 modular amplifiers mountable,
one of which serves as a standby amplifier
2 bus lines and 8 switching zones
One amplifier covers multiple zones
VX-3008F
BGM
matrix
AMP
AMP
BGM VX-3008F
AMP
sbAMP
AMP
BGM
sbAMP
AMP
AMP
matrix
matrix
SS*
SS*
MIC
BGM
SS*
MIC
BGM
sbAMP
SS
AMP
AMP
Zone 1
MIC
BGM
AMP
AMP
SS
MIC
BGM
AMP
AMP
SS
Zone 2
SS
AMP
AMP
Zone 1
Zone 2
Zone 2
MIC
BGM
SS
AMP
AMP
Zone 1
The floor is divided into multiple zones with individual attenuator
No background music required
Announcement is sent to selected zone(s)
VX-3016F
Up to 2 modular amplifiers mountable 16 switching zones
Broadcasting to multiple zones with only one amplifier is possible
Zone 1
Zone 2
MIC
BGM
AMP
AMP
SS
Zone 2
Requirements
Zone 1
Zone 1
Zone 2
VX-3016F
AMP
VX-3016F
matrix
VX-3016F
matrix
AMP
AMP/sb AMP
SS*
SS*
AMP/sb AMP
AMP be
In case of connecting music source,
noted that backgroundmatrix
music is interrupted
by paging announcement.
*SS stands for speaker selector
MIC
BGM
SS*
MIC
BGM
AMP/sb AMP
SS
AMP
Zone 1
MIC
BGM
AMP
SS
MIC
BGM
AMP
SS
Zone 2
SS
AMP
Zone 1
Zone 2
Zone 2
Flexible speaker driving from 1 zone per amplifier up to 64 zones per amplifier
1 zone per amplifier
SS
AMP
VX-3016F
Zone 1
MIC
BGM
AMP
SS
AMP
AMP
AMP
AMP
Up to 64 switching zones
SS
SS
Scalability
One system can be configured with max 40
frames, one of which is set to ID:0 and
serves as a master frame. Up to 4 systems
can be integrated via VX link, allowing to
configure one large–scale system with
maximum 960 audio inputs and maximum
2,560 zones.
System 1
System 2
Max 40 frames
Max 40 frames
Max 240 inputs
Max 640 outputs
etc...
Max 240 inputs
Max 640 outputs
etc...
32
VX link
System 3
Max 40 frames
Max 240 inputs
Max 640 outputs
etc...
32
32
32
SS
Zone 1
Zone 2
SS
AMP
Zone 1
Zone 2
Zone 2
Speaker selector expansion
VX-3004F
matrix
MIC
BGM
Zone 1
System 4
Max 40 frames
Max 240 inputs
Max 640 outputs
etc...
VX-3000 series
Frames
VX-3004F / VX-3008F / VX-3016F Voice Evacuation Frame
VX-3004F front
VX-3004F rear
VX-3008F rear
VX-3016F rear
VX-3004F: up to 4 amps (1-zone - 1 amp, 4 AB-zones or 3 AB
All mandatory indications by EN54-16
zones + standby amp)
Status indication for each speaker line
VX-3008F: up to 3 amps (8 zones switching between 2 amps +
Fault acknowledge and lamp test button
standby amp or 8 zones freely assignable to 1 of 2 amps)
Input DSP: 3-point filters(PEQ/HPF/LPF/High shelving/Low
VX-3016F: up to 2 amps (16 switched zones + standby amp or 2
shelving), VOX and Comp.
x 8 switched zones)
Output DSP: 6-point filters(PEQ/HPF/LPF/High shelving/Low
shelving/All pass/Notch/Horn EQ) and Delay
Specifications
VX-3004F
VX-3008F
Power Source
Speaker Line
VX-3016F
20 to 33 V DC, removable terminal block (4 pins)
4 channels (with AB LINE speaker out)
8 channels
16 channels
No. of Connectors: 2 (LAN A, LAN B) ; Network I/F: 100BASE-TX ; Network Protocol: TCP, UDP, ARP, ICMP, RTP, IGMP, FTP, HTTP ;
Spanning tree Protocol: RSTP ; Audio Transmission System: TOA Packet Audio ; Audio Encoding Method: PCM ; Audio Sampling Frequency: 48 kHz, 16 bits
Connection Device: other VX-3004F, VX-3008F, VX-3016F, NX-300 and Switching HUB, Connector: RJ45 connector ; Connection Cable: CAT5 ; Number of
Strage of Cascade Connection: Up to 7; Max. Cable Distance: 100 m
LAN A, B
RS Link A, B
2 (RS LINK A, RS LINK B) , Up to 8 RM units can be connected to a single VX-3XXXF, up to 4 RM units connectable per RS LINK
DS Link
Connector: RJ45 connector, Connection Cable: CAT5-STP, Max. Cable Distance: 5 m
Analog Link
Number of Connectors: 1 input, 1 output, Connection Device: other VX-3004F, VX-3008F, VX-3016F, Connector: RJ45 connector,
Connection Cable: CAT5-STP or greater, Max. Cable Distance: 800 m
Control Input
16 inputs, no-voltage make contact input, open voltage: 24 V DC, short-circuit current: 2 mA
Fault Detection System: Short circuit, Open circuit, Method: Voltage detect ; Connector: RJ45 connector ; Connection Cable: CAT5-STP or greater
Emergency Control IN
Input 2: Isolated voltage input, -24 to +24 V ; Connector: RJ45 connector ; Connection Cable: CAT5 or greater
VOX Function
Threshold: –60 to 0 dB (1 dB steps), Hysteresis: 0 to +10 dB, Hold time: 10 ms – 10 s, Settable for each audio input
Control Output
General outputs : 8 with CONTROL OUTPUT 1 ; Exclusive outputs : 3 with CONTROL OUTPUT 2 ; GENERAL FAULT, CPU FAULT, CPU OFF
No-voltage make contact, electrical contact output, control current: 10 mA ; withstand voltage: 28 V DC ;
Connector: RJ45 connector ; Connection Cable: CAT5-STP or greater
ATT/Control Output
8 outputs, no-voltage make contact, relay contact (NC, NO, C), control current: 2 mA to 5 A ;
withstand voltage: 125 V AC, 40 V DV ; Connector: Removable terminal block (12 pins) x 2
DSP
16 outputs, no-voltage make contact, relay contact (NC, NO,
C), control current: 2 mA to 5 A; withstand voltage: 125 V AC,
40 V DV ; Connector: Removable terminal block (12 pins) x 4
Feedback suppression, Equalizer/Filter, Compressor, Delay and Ambient Noise Control (ANC)
Audio Input
4 inputs (Line: -20 dBV / Mic: -60 dBV / ANC sensor, phantom power selectable)
Standby Amplifier
Input: 1, Output: 1 ; Max. Voltage/Current: 100 Vrms, 5 Arms ; Connector: Removable terminal block (2 pins) x 2
Extension Amplifier
-
Input: 2, Output: 2, Max. Voltage/Current: 100
Vrms, 5 Arms, Connector: R emovable terminal
block (2 pins) x 4
Input: 1, Output: 1 ; Max. Voltage/Current: 100 Vrms, 5 Arms ;
Connector: Removable terminal block
(2 pins) x 2
Power Amplifier
4
3
2
7.6 kg
7.9 kg
Dimensions (W x H x D)
Weight
483 x 132.6 x 345 mm (19”, 3U)
8.1 kg
VX-3000 series
Amplifiers / EOL Unit
VX-015DA / VX-030DA / VX-050DA Digital Power Amplifier Module
Low loss modular class D amplifiers
Modules to be mounted in the frame units
Three different power levels: 150 W, 300 W or 500 W
Can easily be removed or replaced simply by unplugging
them; no need for special tools
Dust filter, easy to clean
100 V Output without transformer resulting in
light-weight units
Fuse easily accessible from rear
Specifications
VX-015DA
VX-030DA
Applicable Model
VX-050DA
VX-3004F, VX-3008F, VX-3016F
Power Source
31 V DC (operating range: 20 to 33 V DC) DC power in: M4 screw terminal, distance between barriers: 11mm
Amplification System
Class D
Power Consumption
1.3 W (standby mode), 14 W (no audio input),
40 W (1/8 rated output), 190 W (rated output)
at 31 V DC,
output voltage selection switch: 100 V
1.3 W (standby mode), 14 W (no audio input),
60 W (1/8 rated output), 375 W (rated output)
at 31 V DC,
output voltage selection switch: 100 V
1.3 W (standby mode), 16 W (no audio input),
100 W (1/8 rated output), 590 W (rated output)
at 31 V DC,
output voltage selection switch: 100 V
Rated Output Power
150 W (at 100 V line)
105 W (at 70 V line)
75 W (at 50 V line)
(at min. impedance & max. capacitive load)
(at AC mains VX-3000DS : 187 - 253 V)
300 W (at 100 V line)
210 W (at 70 V line)
150 W (at 50 V line)
(at min. impedance & max. capacitive load)
(at AC Mains VX-3000DS: 187 - 253 V)
500 W (at 100 V line)
350 W (at 70 V line)
250 W (at 50 V line)
(at min. impedance & max. capacitive load)
(at AC Mains VX-3000DS: 187 - 253 V)
Output Voltage
Min. Resistive Load
100 V (70 V, 50 V: selectable)
67Ω (100 V), 47Ω (70 V), 33Ω (50 V)
33Ω (100 V), 23Ω (70 V ), 17Ω (50 V)
Frequency Response
40 Hz to 20 kHz: - 5 to +1 dB
Distortion
1 % or less (at 100 V line, A-weighted)
Dimensions (W x H x D)
Weight
20Ω (100 V), 14 Ω (70 V), 10Ω (50 V)
0.5 µF
Max. Capacitive Load
82.8 x 91 x 358.2 mm
1.3 kg
1.4 kg
VM-300SV End of Line Unit
Speaker line failure can be detected with high accuracy
Module for installation between the speaker line end and
the emergency input terminal of the VX-3008F and VX3016F.
VX-3000 series
Power Supply
VX-3000DS Power Supply Manager
DC power supply to all system components
Combination of two built-in power source units with a highperformance charger
Automatical switch to auxiliary battery power if the AC
power supply is down
VX-3000DS: EN 54-4 certified,
Certificate No: 1134-CPR-137
Specifications
Power Source
Power Consumption
DC Power Output (AC mode)
VX-3000DS
220 – 230 V AC, 50/60 Hz
2800 W max in total (at rated output with charging), 650 w max in total, 350 W max each (EN 60065)
Rated output: 2300 W (total DC power output), Peak output: 2780 W (total DC power output)
DC Power Output
8 x 31 V (19 – 33 V) 25 A max. each, M4 screw terminal, distance between barriers: 11 mm
3 x 31 V (19 – 33 V) 5 A max. each, removable terminal block (3 x 2 pins)
1 x 24 V (16 – 25 V) 0.3 A max., removable terminal block (1 x 2 pins)
Charging Method
Temperature compensated trickle charging
Charging Output Voltage
27.3 V +/- 0.3 V (at 25 ˚C), Temperature correction coefficient: -40 mV/ ˚C
Battery Connection
One each positive and negative terminal, applicable cable diameter: AWG 6 – AWG 0 (AWG 1/0) (16 mm2 – 50 mm2)
Line resistance within 4 mΩ/ total
Control Connector
DS LINK IN/OUT
RJ45 female connector for connecting the system and cascade connection,
Shielded Twisted-pair straight cable (TIA/EIA-568A standard)
Type of control signal: Battery check, AC power status, DC power status, charging circuit failure, battery failure, and communication
Panel Indicator
Dimensions (W x H x D)
Weight
AC power IN 1, IN 2 (Green), Charging (Green), Battery power (Green), Battery connect (Green), Battery condition (Green)
482 x 132.6 x 400.5 mm (19”, 3U)
11.8 kg
VX-3000 series
Emergency Remote Microphone
RM-200SF / RM-320F Wall Mount Remote Microphone / Extension
For emergency broadcast
For activation of emergency mode, start and stop automatic
broadcasts of emergency announcements, reset
emergency signals, and live microphone announcements
CPU-switch for emergency broadcast to all zones even in
Alarm Switch
case of a CPU error
Up to 4 RM-320F Remote Microphone Extension units can
be used with each RM-200SF Remote Microphone
RM-200SF
Microphone
Options
RM-320F: Key extension unit
RM-210: Key extension unit
RM-320F
WB-RM200: Wall-mounting bracket
Specifications
RM-200SF
RM-320F
Power Source
24 V DC (operating range: 15 – 40 V DC)
From remote microphone
Current Consumption
240 mA or less
180 mA max.
Distortion
1 % or less
-
Frequency Response
200 Hz – 15 kHz
-
Signal-to-Noise Ratio
55 dB or more
-
Audio Output
0 dBV, transformer-balanced
-
Microphone
Unidirectional dynamic microphone with talk key, AGC (ON/OFF switchable)
-
Chime
Built inside (PCM sound source), Monitoring available with a built-in speaker
Volume Control
Microphone volume, Monitor speaker volume, Chime volume (using the software)
Connection Cable
Main line: Shielded CPEV cable or Shielded Category 5 twisted pair cable for LAN
Connection to RM-200SF by dedicated cable
(CAT5-STP), M3 screw terminal
No. of Connectable RM -320F
Max. 4 units
-
Key Operation
Emergency key, Talk key, 3 Function keys
20 Function keys
Finish
ABS resin, bluish gray (PANTONE 538 or its equivalent)
Dimensions (W x H x D)
200 x 215 x 95 mm
175 x 215 x 70 mm
Weight
1.48 kg
700 g
-
VX-3000 series
Remote Microphone
RM-300X / RM-210F Remote Microphone / Extension
For both emergency and general purpose broadcast
Zone selection or all call
PC-programmable system software permits desired
functions to be assigned to individual function keys
(equipped with 2 LED indicators)
RM-210F: Key extension unit with 10 additional keys
Up to 7 RM-210F Remote Microphone Extension units can
be used with each RM-300X Remote Microphone
Options
AD-246: Power supply unit
RM-210F
RM-300X
Specifications
WB-RM200: Wall-mounting bracket
RM-300X
RM-210F
Power Source
24 V DC (operating range: 15 - 40 V DC), supplied
from the audio input unit or DC input power supply connector
Supplied from the optional RM -300X
Current Consumption
240 mA or less
80 mA or less
Audio Output
0 dBV, 600 Ω, balanced
-
External Microphone Input
-40 dBV, 2.2 kΩ, unbalanced, ø3.5 mm phone jack, phantom powering
[When used as AUX input] −20 dBV, 4.7 kΩ, unbalanced
-
Frequency Response
100 Hz – 20 kHz
-
Distortion
1 % or less
-
Signal-to-noise Ratio
60 dB or more
Microphone
Unidirectional electret condenser microphone with AGC (ON/OFF selectable)
Chime
Built inside (PCM sound source), Monitoring available with a built-in speaker
Volume Control
Microphone volume, Monitor speaker volume, Chime volume (using the software)
Connectable Cable
Main line: Shielded CPEV cable or Shielded Category 5 twisted pair cable for LAN (CAT5STP), Branch line: Shielded Category 5 twisted pair cable (CAT5-STP), RJ45 connector
No. of Connectable RM-210F
Max. 7 units
Operation
Emergency/all-zone emergency broadcast key, Talk key, 13 Function keys
Finish
-
10 Function keys
ABS resin, black
Dimensions (W x H x D)
190 x 76.5 x 215 mm (gooseneck microphone excluded)
110 x 76.5 x 215 mm
Weight
880 g
350 g
RM-200RJ Terminal Unit
Convert the RJ45 connector into a screw terminal block
Used to connect between a trunk cable (such as CPEV
cable) and a feeder cable (such as CAT-5 or CAT-6 cable) in
wiring a remote microphone
Built-in indicator shows the voltage status of DC power
cable when the remote microphone cable for the VX-3000
series system is connected
Specifications are subject to change without notice. (201810)8336110042-03
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising