Advertisement
Advertisement
Operating Instructions Precision Pressure Indicator CPG2500 Precision Pressure Indicator CPG2500 PN 0018908001P• 09/2019 Precision Pressure Indicator CPG2500 ! Warning ! This Warning symbol indicates that danger of injury for persons and the environment and/or considerable damage (mortal danger, danger of injury) will occur if the respective safety precautions are not taken. This Caution symbol indicates danger for the system and material if the respective safety precautions are not taken. Caution i Notice 2 This Notice symbol does not indicate safety notices but information for a better understanding of the facts. Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 1. General Information Table of Contents 7 1.1 Warranty7 1.2 Important Notice 7 1.4 Trademarks and Copyrights 8 1.3 FCC Radio Frequency Emission Notice 1.5 Software License Agreement 1.6 Mensor Service Plus 1.6.1 After the Warranty 1.6.3 Certifications and Accreditations 1.6.2 Calibration Services 1.7 Packaging for Shipment 2. Safety Notices 2.1 User Responsibilities 2.2 General Safety Notices 2.3 Warnings and Caution Notices 3. General Description 7 8 8 8 8 8 8 9 9 9 10 11 3.1 Features11 3.2 Turning On 3.3 Front Panel 12 12 3.4 Display13 3.5 Chassis Assembly 13 4. Specifications 14 4.1.1 15 4.1 Transducer Specification Measurement & General Specifications 14 5. Installation 17 5.2 Dimensions (inches) 18 5.1 Unpacking the Instrument 17 5.3 Mounting19 5.4 Rear Panel 19 5.4.1 Pressure Connections 20 5.4.3 Reference Port 20 5.4.2 Pressure Port 5.5 Remote Communication Connections 5.6 Power Up 5.7 Electrical Block Diagram 6. Local Operation and Setup 6.1 General Operation Operating Instructions - CPG2500 20 20 20 21 22 22 3 Precision Pressure Indicator CPG2500 6.1.1 6.1.2 Setup Applications Display Screen Features 6.2 Initial Setup 6.2.1 6.2.2 Contact and Version Information Application Language Selection 6.3 Application Selection and parameter inputs 6.4 Applications: 6.4.1 Measure Application 6.4.1.1 Pressure Mode / Emulation Mode 6.4.1.3 Zero Button 6.4.1.2 22 23 23 23 24 25 25 26 27 27 6.4.1.4 Tare Button 6.4.2.1 Languages30 6.4.2.3 Volume31 6.4.2.5 Barometer Units 6.4.2 Settings Application 6.4.2.2 6.4.2.4 6.4.2.6 6.4.3 6.4.3.2 6.4.4 User base units / Base units multiplier 32 Configuration 33 Frame Format Frames Channel 6.4.4.1 Transducer Channel Selection 6.4.4.3 Transducer Filter Transducer Delta Emulation 6.4.4.4 Transducer Resolution 6.4.4.6 Cal Function 6.4.4.5 6.4.5 Auxiliary Displays Remote Application 6.4.5.1 6.4.5.2 30 31 Transducer Application 6.4.4.2 29 Brightness Frames Application 6.4.3.1 Remote Command Set Remote Communication Settings 32 34 34 35 36 36 37 37 38 39 40 41 41 42 6.4.6 Info Application 43 6.4.8 Troubleshooting Application 45 6.4.7 6.4.9 Leak Test Application Logging Application 6.4.9.1 6.4.9.2 4 Auxiliary Displays 22 Remote Logging Pressure Logging 44 46 46 47 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 6.4.10 Service Application 6.4.11 Unlocked Service Application 7. Remote Operation 7.1 Command Set 48 49 51 51 7.2 IEEE-48851 7.2.1 IEEE-488.2 Commands 51 7.3 Ethernet52 7.4 Serial53 7.4.1 Serial Cable Requirements 7.5 Mensor Command Set 7.6 Command and Query Format 7.7 Command Set Definitions 7.8 Output Formats 7.9 CPG2500 Commands and Queries 53 54 54 54 55 55 7.9.1 Units Command Syntax for Measurement Units 62 7.9.3 SCPI Commands and Queries 63 7.9.2 7.9.4 7.9.5 7.9.6 7.10 CPG2500 Error Codes SCPI Commands Error Messages and Error Codes GPIB Capability Codes Interface Functions USB Software Upgrade 8. Options 63 65 65 65 66 68 8.1 Barometer68 8.2 Barometric Reference (CPX-A-G1-3-J of CPX-A-G1-3-D) 68 8.2.1 Absolute Pressure Emulation 68 8.2.3 Barometric Reference Calibration 69 8.2.2 8.2.4 Emulation Mode Accuracy Barometric Reference Specifications 8.3 Delta Channel 8.4 External Transducers (CPT9000, CPR2510, CPT6100 and CPT6180) 8.4.1 External Pressure Sensor Connection Cable 8.5 External Sensor Package (D-Sub) 8.6 Analog Output 8.6.1 Specifications 8.7 Rack Mount Kit (CPX-A-G1-D of CPX-A-G1-R) 8.8 Fittings (CPX-A-G1-M, CPX-A-G1-C, CPX-A-G1-B, CPX-A-G1-I, CPX-A-G1-E, CPX-A-G1-N, CPX-A-G1-A, CPX-A-G1-S, CPX-A-G1-F) 8.9 Remote Calibration (CPX-A-G1-4 or CPX-A-G1-5) Operating Instructions - CPG2500 69 69 69 69 69 70 70 70 70 70 70 5 Precision Pressure Indicator CPG2500 8.9.1 Remote Calibration Kit for Internal Transducers. 8.9.3 External Calibration Procedures 8.9.2 Barometric Reference Calibration Sled 8.9.3.1 8.9.3.2 Transducer Removal Barometric Reference Removal 72 72 73 73 73 9. Maintenance 74 9.2 Spare Parts 74 9.1 Beyond the Warranty 10. Calibration 75 10.1 Environment75 10.3 Media75 10.2 10.4 10.5 Pressure Standards 75 Setup76 Service Application 77 10.6 Calibration Data 79 10.8 Two Point Cal Application 10.5.1 Service Application (unlocked) 10.7 10.9 10.10 One Point Cal Application Head Pressure 11.1 Conversion Factors, PSI 11.3 Conversion Factors, Pascal 11.2 78 79 80 Linearization81 11. Appendix 6 74 Conversion Factors, Millitorr 83 85 86 87 88 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 1 General Information 1.1 Warranty All products manufactured by Mensor are warranted to be free of defects in workmanship and materials for a period of two years from the date of shipment. No other express warranty is given, and no affirmation of Seller, by words or actions, shall constitute a warranty. SELLER DISCLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSES WHATSOEVER. If any defect in workmanship or material should develop under conditions of normal use and service within the warranty period, repairs will be made at no charge to the original purchaser, upon delivery of the product(s) to the factory, shipping charges prepaid. If inspection by Mensor or its authorized representative reveals that the product was damaged by accident, alteration, misuse, abuse, faulty installation or other causes beyond the control of Mensor, this warranty does not apply. The judgment of Mensor will be final as to all matters concerning condition of the product, the cause and nature of a defect, and the necessity or manner of repair. Service, repairs or disassembly of the product in any manner, performed without specific factory permission, voids this warranty. MENSOR MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MANUAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Mensor shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. 1.2 Important Notice The product specifications and other information contained in this manual are subject to change without notice. Mensor has made a concerted effort to provide complete and current information for the proper use of the equipment. If there are questions regarding this manual or the proper use of the equipment, contact Mensor at: Mensor WIKA Alexander Wiegand SE & Co. KG 201 Barnes Drive Alexander-Wiegand-Straße 30 San Marcos, Tx 78666 D-63911 Klingenberg / Germany Tel: 1.512.396.4200 Tel: (+49) 93 72/132-9986 1.800.984.4200 (USA only) web site: www.wika.de web site: www.mensor.com fax: (+49) 93 72/132-8767 fax: 512.396.1820e-mail: [email protected] e-mail: [email protected] [email protected] 1.3 FCC Radio Frequency Emission Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his or her own expense. USE SHIELDED CABLES TO CONNECT EXTERNAL DEVICES TO THIS INSTRUMENT TO MINIMIZE RF RADIATION. Operating Instructions - CPG2500 7 Precision Pressure Indicator CPG2500 1.4 Trademarks and Copyrights Mensor is a registered trademark of Mensor, LP. All other brand and product names are trademarks or registered trademarks of their respective companies. ©2007, Mensor, LP. All rights reserved. 1.5 Software License Agreement This product contains intellectual property, i.e., software programs, that are licensed for use by the end user/customer (hereinafter “end user”). This is not a sale of such intellectual property. The end user shall not copy, disassemble or reverse compile the software program. i Notice The software programs are provided to the end user “as is” without warranty of any kind, either express or implied, including, but not limited to, warranties of merchantability and fitness for a particular purpose. The entire risk of the quality and performance of the software program is with the end user. Mensor and its suppliers shall not be held to any liability for any damages suffered or incurred by the end user (including, but not limited to, general, special, consequential or incidental damages including damages for loss of business profits, business interruption, loss of business information and the like), arising from or in connection with the delivery, use or performance of the software program. 1.6 Mensor Service Plus If you have problems and you don’t find the answer in this manual, contact Mensor at 1.800.984.4200 (USA only) or 1.512.396.4200 for personal assistance, or at any of the contact addresses listed on the rear cover of this manual. We are ready to help. 1.6.1 After the Warranty Mensor’s concern with the performance of this instrument is not limited to the warranty period. We provide complete repair, calibration and certification services after the warranty for a nominal fee. 1.6.2 Calibration Services In addition to servicing our own products Mensor can perform a complete pressure calibration service, up to 30,000 psi, for all of your pressure instruments. This service includes an accredited calibration. 1.6.3 Certifications and Accreditations Mensor is registered to ISO 9001:2015. The calibration program at Mensor is accredited by A2LA, as complying with both the ISO/IEC 17025:2017 and the ANSI/NCSL Z540-1-1994 standards. 1.7 Packaging for Shipment If the product must be shipped to a different location or returned to Mensor for any reason through a common carrier it must be packaged properly to minimize the risk of damage. The recommended method of packing is to place the instrument in a container, surrounded on all sides with at least four inches of shock attenuation material such as styrofoam peanuts. Strictly observe the following when shipping the instrument: All instruments delivered to WIKA or Mensor must be free from any kind of hazardous substances (acids, bases, solutions, etc.) and must be cleaned before being returned. 8 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 WARNING! Physical injuries and damage to property and the environment through residual media Residual media in the dismounted instrument can result in a risk to persons, the environment and equipment. ▶▶ With hazardous substances, include the material safety data sheet for the corresponding medium. When returning the instrument, use the original packaging or a suitable transport packaging. To avoid damage: 1. Wrap the instrument in an anti-static plastic film. 2. Place the instrument along with shock-absorbent material in the packaging. Place shock-absorbent material evenly on all sides of the transport packaging. 3. If possible, place a bag containing a desiccant inside the packaging. 4. Label the shipment as a highly sensitive measuring instrument. Instruments with lithium ion rechargeable batteries or lithium metal batteries The included lithium ion rechargeable batteries or lithium metal batteries are subject to the requirements of the dangerous Goods Act. For shipping, special packaging and labelling requirements must be observed. A dangerous goods expert must be consulted when preparing the item to be shipped. Do not send any damaged or defective rechargeable batteries. Cover open contacts with adhesive tape and package the rechargeable battery such that it cannot move inside the package and short circuits are prevented. The different requirements of the relevant transport carriers as regard to the Dangerous Goods Act and also additional national regulations must be observed. Information on returns can be found under the heading “Service” on our local website. Operating Instructions - CPG2500 9 Precision Pressure Indicator CPG2500 5 Safety Notices 5.1 User Responsibilities To ensure safety, the user must make sure that: • The system is used properly, no dangerous media are used and that all technical specifications are observed. • The system is operated in perfect operating condition. • This operation manual is legible and accessible to the user at the system’s location. • The system is operated, serviced and repaired only by authorized and qualified personnel. • The operator receives instruction on industrial safety and environmental protection, and is knowledgeable of the operating instructions and the safety notices contained therein. 5.2 i General Safety Notices The system should only be operated by trained personnel who are familiar with this manual and the operation of the instrument. Notice ! Warning i WARNING: A condition for trouble-free and safe operation of this system is proper transport, proper storage, installation, assembly and proper use as well as careful operation and maintenance. Any operation not described in the following instructions should be prohibited. The system must be handled with care required for an electronic precision instrument (protect from humidity, impacts, strong magnetic fields, static electricity and extreme temperatures). Do not insert any objects into the instrument. The system is powered via the power cable with a voltage that can cause physical injury. Even after disconnecting the system from the power supply, dangerous voltages can temporarily occur due to capacitance. Extreme care must be taken with pressure connections when using hazardous or toxic media. Repairs must only be performed by authorized service personnel. Additional safety notices are found throughout this manual. Notice 10 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 5.3 Warnings and Caution Notices ! Warning WARNING: HIGH PRESSURE! High pressure gases are potentially hazardous. Energy stored in these gases and liquids can be released suddenly and with extreme force. High pressure systems should be assembled and operated only by personnel who have been trained in proper safety practices. ! WARNING: NOT EXPLOSION PROOF! Installation of this instrument in an area requiring devices rated as intrinsically safe is not recommended. ! WARNING: POSSIBLE INJURY! The tubing, valves, and other apparatus attached to the gauge must be adequate for the maximum pressure which will be applied, otherwise physical injury to the operator or bystanders is possible. ! CAUTION: USE THE PROPER PRESSURE MEDIUM! Use only clean, dry, non-corrosive gases unless otherwise specified by Mensor. This instrument is not designed for oxygen use. ! CAUTION: As with most sensitive electronic equipment, switch the power switch off before connecting or disconnecting to a power source to prevent data loss. Do not position the equipment so that it is difficult to disconnect the DC power jack. Warning Warning Caution Caution CAUTION: ESD PROTECTION REQUIRED. The proper use of grounded work surfaces and personal wrist straps are required when coming into contact with exposed circuits (printed circuit boards) to prevent static discharge to sensitive electronic components. Additional Warning and Caution notices are found throughout this manual. Operating Instructions - CPG2500 11 Precision Pressure Indicator CPG2500 6 General Description The CPG2500 Precision Pressure Indicator is a multi-channel pressure indicator designed to test and calibrate a variety of pressure devices in either absolute or gauge pressure modes. The CPG2500 can have two independent internal transducers, an optional barometric reference and an external remote pressure transducer. Figure 3.1 - Desk top version 6.1 Features Here is a short list of significant features designed into the CPG2500: • Up to two removable / interchangeable, highly stable, temperature compensated, internal pressure transducers. (Option to connect two external transducers via a rear mounted RS-232 port in place of the two internal transducers) • An optional remote transducer in addition to the two internal transducers. • An optional removable / interchangeable internal high accuracy barometric reference transducer providing gauge pressure emulation for absolute ranges and absolute pressure emulation for gauge ranges. • Optional Analog output for each internal sensor. • 7” Color LCD with touch screen • Delta function when two or more transducers are installed • Multiple languages; change the language for on-screen text and number/date formats by simply touching one of the “national flag” icons available in the setup screen. • Desk top or rack mount • Local Operation, or command and read remotely. 12 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 6.2 Turning On You can confirm that your CPG2500 is operational right now. Apply power to the power connector on the rear of the instrument with the included power adapter, remove any plastic plugs from the rear panel pressure ports, and press the power switch to ON. The system will go through an initialization process, which takes about 45 seconds, and then a display will appear similar to the screen shown below. Power Switch ON/OFF To see information about the configuration of your new CPG2500, touch the Information Application (App) icon on the menu and a window will appear listing the Mensor customer service contact, model number and the sensors that are installed. Press the Measure App [ ] to return to the main screen. Information Application 6.3 Front Panel The CPG2500 front panel includes a 7” color LCD with touch screen. Operator input is accomplished by pressing the words or App icons presented on the display. There is a single discrete on/off button and a USB on the right hand side. The front panel also shows the model number designation and brand logos. Operating Instructions - CPG2500 13 Precision Pressure Indicator CPG2500 6.4 Display The display is made up of two sections. In the main screen (“Measure Application”), the left two thirds shows the transducer channels that are configured for display, along with the pressure reading, units, mode (absolute or gauge), channel label, an auto zero or tare button (if enabled) and any auxiliary indications that have been chosen. The right one third of the screen has Application Icons (“Apps”) for setting viewing options, sensor settings, communication settings plus a “Page Down” button [ ] that, when pressed, shows a second and third page of icons for calibration, remote communication error checking and a leak test application. Page Down Channel label and range Auto Zero Reading Units and Mode Auxiliary Indications Transducer Channels Settings Apps Buttons, Labels and Windows: The CPG2500 touch screen has many buttons with relevant graphic icons or text which, when pressed, will open a related window where changes can be made or information viewed. Some of these buttons will toggle from one state to another, others present choices or display a numerical data entry screen. Text or icons that are displayed, but do not respond to being touched, are called labels or windows. Operators will quickly become accustomed to the particular characteristics of the frequently used buttons. Main Screen: The main screen or “Measure Application”, appears after power-up. This screen contains the channel frames and settings button. It will remain as configured after a power cycle. Transducer Channel Frame(s): The transducer channel frames (left 2/3 of the screen) contain information specific to a channel. Up to three channels can be displayed at once, two are shown in the picture above. The channel frames are color coded with channel A - green, channel B - blue and the remote channel - red. The optional barometer channel is sky-blue and the delta channel is yellow. If only one channel is installed, a full frame will be displayed in the color of the channel connected. The channel frame contains the pressure reading, units, and mode(absolute or gauge) plus any auxiliary displays that have been chosen. 6.5 Chassis Assembly The chassis assembly is the housing for the system and the removable transducers. The system has no user-serviceable parts, and therefore the chassis should not be opened except by qualified repair personnel at Mensor or certified service locations for any reason except to change the removable transducers. 14 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 7 Specifications Accuracy specifications presented herein are obtained by comparison with primary standards traceable to a national metrology institute or recognized international standard organization. These specifications are obtained in accordance with the ISO Guide to the Expression of Uncertainty in Measurement (GUM). The calibration program at Mensor is accredited by the American Association of Laboratory Accreditation (A2LA) as complying with both the ISO/IEC 17025:2017 and the ANSI/NCSL Z540-1-1994 standards. If there is an exception to the requirements and recommendations of Z540 during a calibration the exception is noted on the individual calibration certificate. Mensor reserves the right to change specifications without notice. 7.1 Transducer Specification Standard Reference Transducers, Model CPR2550 Accuracy(1) Gauge Pressure Bi-Directional Pressure Absolute Pressure(4)(5) Precision(6) Calibration Interval Media Compatibility Wetted parts Pressure media Sensor Reading rate Calibration adjustments Operating Instructions - CPG2500 0.01%FS(3) 0 ... 0.36 up to 10,000 psi 4) 0 ... 25 mbar up to 700 bar 0.01%IS-50(2) 0 ...14.5 up to 6000 psi 4) 0 ... 1 up to 400 bar -0.18. ... 0.18 to -14.5 ... 10,000 psi 4) -12.5 ... 12.5 mbar to -1 ... 700 bar -14.5 ... 145 to -14.5 ... 6000 psi 4) -1 ... 10 to -1 ... 400 bar 0.004%FS 0.004%FS 0 ... 7.5 up to 10,015 psi 0 ... 0.5 up to 701 bar 365 days(7) 0 ... 14.5 up to 6015 psi 0 ... 1 up to 401 bar 365 days 6000/7000 series Aluminum, 316 SS, brass, PTFE (Teflon®), Urethane, Silicone, RTV, Silicone grease, PVC, Epoxy, Buna-N, fluoroelastomers (Viton®) Ranges ≤ 10,015 psi – Pneumatic media Ranges > 15 psi – Hydraulic media allowed 33 readings/second Internal zero adder and span multiplier, up to 11 point linearization for each sensor 15 Precision Pressure Indicator CPG2500 Premium Reference Transducers, Model CPR2580 Accuracy(1) Gauge Pressure Absolute Pressure(4) Precision(6) 0.008% IS-33(8) 0.008% IS-50(9) 0.01% FS(3) 0.014% FS(3) 0 ... 12 to 0 ...16.5 psia 0 ... 18.4 to 0 ... 33 psia 0 ... 36 to 0 ... 50 psia 0 ... 80 to 0 ... 110 psia 0 ... 160 to 0 ... 220 psia 0 ... 240 to 0 ... 500 psia 0 ... 700 to 0 ... 1100 psia 0 ... 1400 to 0 ... 3300 psia 0 ... 4200 to 0 ... 6600 psia 0 ... 8000 to 0 ... 11,000 psia 0 ... 12,000 to 0 ... 22,000 psia 0 ... 24,000 to 0 ... 31,500 psia 0 ... 32,000 to 0 ... 42,000 psia 365 days 0.004%FS 365 days 0.004%FS 0.004%FS 0 ... 12 to 0 ...16.5 psig 0 ... 17.5 to 0 ... 33 psig 0 ... 80 to 0 ... 110 psig 0 ... 120 to 0 ... 220 psig Calibration Interval (7) 0.004% FS Media Compatibility Wetted parts Pressure media Sensor Reading rate Calibration adjustment — — 365 days — 365 days 6000/7000 series Aluminum, 316 SS, brass, PTFE (Teflon®), Urethane, Silicone, RTV, Silicone grease, PVC, Epoxy, Buna-N, fluoroelastomers (Viton®) Hydraulic media only available > 6,015 psia 10 readings/second Internal Zero adder and Span multiplier, up to 11 point linearization for each sensor It is defined by the total measurement uncertainty, with the coverage factor (k = 2) and includes the intrinsic performance of the instrument, the measurement uncertainty of the reference instrument, long-term stability, influence of ambient conditions, drift and temperature effects over the compensated range with recommended zero point adjustment every 30 days. 0.01 % IS-50 accuracy: Between 0 ... 50 % of the full scale, the accuracy is 0.01% of half of the full scale value and between 50 ... 100 % of the full scale, the accuracy is 0.01 % of reading. (3) FS = full span. (4) Ranges from 1500 to 2000 psig will be sealed gauge transducers. (5) The minimum calibrated range of absolute transducer(s) is 600 mTorr. (6) It is defined as the combined effects of linearity, repeatability and hysteresis throughout the stated compensated temperature range. (7) 180 days for pressure ranges (absolute and gauge) below 1 bar (15 psi) and -1...1 bar (-15...14.5 psi) bidirectional. 365 days for the remainder of specified ranges. (8) 0.008 % IS-33 accuracy: Between 0 ... 33 % of the full scale, the accuracy is 0.008% of one third of the full scale value and between 33 ... 100 % of the full scale, the accuracy is 0.008 % of reading. (9) 0.008 % IS-50 accuracy: Between 0 ... 50 % of the full scale, the accuracy is 0.008% of half of the full scale value and between 50 ... 100 % of the full scale, the accuracy is 0.008 % of reading. (1) (2) 7.1.1 Measurement & General Specifications Basic Instrument Instrument Instrument version Dimensions Weight Warm-up time Display Standard: Table top with tilt feet Option: -19” rack-mounting for single instrument mount. -19” rack-mounting for dual instrument mount. See technical drawing 12.5 lbs./ 5.7 kg (with all internal options) Approximately 15 minutes Screen 7” color LCD Data entry Touch screen keypad Resolution Measurement Units 16 Selectable from 4 to 7 digits, depending on range and units psi, psf, osi, atm, inH20@4C, inH20@20C, inH20@60F, mbar, bar, Dy/cm2, pascal, hPa, kPa, MPa, inHg@0C, inHg@60F, mTorr, Torr, mmHg@0C, cmHg@0C, mHg@0C, mmH20@4C, cmH20@4C, mH20@4C, mmH20@20C, cmH20@20C, mH20@20C, mSW, ftH20@4C, ftH20@20C, ftH20@60F, inSW, ftSW, tsi, tsf, g/cm2, kg/cm2, kg/m2, % of Range, + plus 2 user defined units (multiplier from psi, bar or pascal) Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 Rate Units /sec., /min., /hr., /3-hr Measurement filters Off, Low, Normal (default), High Languages Connections English, German, Spanish, French, Italian, Portuguese, Polish, Russian, Chinese, Japanese, Korean Number of integrated transducer (selectable) Standard: 1 reference transducer Optional: 2nd reference transducers, external transducer, internal barometric reference Pressure adaptors Standard: None Optional: For up to 6015 psi, 1/4 inch tube fittings, 6 mm tube fittings, 1/4 in. feamle NPT fittings,1/8 in. female NPT fittings or 1/8 in. female BSP fittings. Pressure connections Overpressure limits Voltage supply Power input requirements Switching power supply Permissible ambient conditions To 6015 psi: Up to 4 ports 7/16 - 20 female SAE. 1 10-32 UNF female port. Ranges >6015 psi: Up to 2 Autoclave F250C/HIP HF4 110 % FS typical, optional external relief valves are available 100-120 or 200-240 VAC, 50-60Hz, 24VA max Output: 12 VDC, 1.7 A (includes 4 region specific plugs adapters) Storage temperature range 0 to 70 deg C Operating temperature range 15 ... 45 deg C Operating environment Operating Altitude Communications Remote interface Command sets 0 ... 95 % RH (relative humidity, non-condensing) <3048 meters (10,000 ft) IEEE 488, RS-232, USB and Ethernet Mensor, WIKA SCPI CE conformity and certificates CE compliance RoHS directive Calibration Operating Instructions - CPG2500 EN61326-1:2013 electromagnetic compliance EN61010-1:2010 safety/CB scheme 2011/65/EU, aticle 4 Calibration certificate per ISO/IEC 17025:2017. Accreditation is by the American Association for Laboratory Accreditation (A2LA). 17 Precision Pressure Indicator CPG2500 8 Installation 8.1 Unpacking the Instrument In addition to functional testing, each unit is inspected for appearance prior to leaving the factory. Upon receipt, please examine the instrument for shipping damage. Report any apparent damage to the carrier immediately. In addition to this manual you should have: • • • • • CPG2500 Precision Pressure Indicator; Power Supply; Fitting adapters ordered; Any accessories ordered; An envelope containing the calibration certificate. 18 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 8.2 Dimensions (inches) Desk top case Front view Side view 19” rack mount Single mount - Front view Dual mount - Front view Rear Panel Baro ref port (baro ref option) IEEE-488 Remote Transducer connection RS-232 USB (device) USB (host) Ethernet port Power Operating Instructions - CPG2500 Measure port Channel B (7/16-20 UNF) Measure port Channel A (7/16-20 UNF) 19 Precision Pressure Indicator CPG2500 8.3 Mounting The instrument can be set up on a desk top or it can be rack-mounted. Rack mount hardware is optional on the CPG2500 (see Section 5.2 Dimensions and Section 8, Options). The special sensors used in the CPG2500 are relatively insensitive to tilt and vibration. However to further assure stability and accuracy, avoid mounting the instrument on surfaces subject to excessive motor or machinery vibration. 8.4 Rear Panel Two slots are available on the rear of the CPG2500. These slots can be filled with a removable transducer or a remote transducer interface connection. Gauge Transducers will have a reference and a pressure port. Absolute transducers will have a plug in the reference port. In the upper right corner is a hose barb fitting which is connected to the baro ref if installed. Transducers with analog output will have an electrical connection. Positioned on the left side is a remote transducer connection, the RS-232, Ethernet, IEEE488, USB device connections for communication, the USB host connection and the 12 VDC power input. Figure 5.4 A - Two removable gauge transducers installed Figure 5.4 B - Two remote transducer interface connections installed 20 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 8.4.1 Pressure Connections i When making up a connection to an o-ring adapter fitting port use a back-up wrench to prevent over-stressing the threads in the manifold block. Notice For pressure range less than 6015 psi, the pressure ports on the rear are female 7/16 - 20 SAE/MS straight threads per MS16142 and SAE J514 table 14. Connected adaptors require a tube fitting boss seal with an o-ring per MS33656. Mensor can provide a variety of adapter fittings (see Section 8 Options) with the instrument. Do not use sealant on fittings sealed with an o-ring. The integrity of each seal is particularly important since even microscopic leaks can cause errors in pressure measurements. For a pressure range greater than 6015 psi, a fixed Autoclave F250C/HIP HF4 fitting is attached. 8.4.2 Pressure Port The CPG2500 will precisely measure the pressure connected to the pressure port up to the full scale range of the transducer installed. 8.4.3 Reference Port The reference port is available on gauge units that have sensors that are not sealed gauge units. For these units this port is available to connect to the reference side of the sensor. This port is normally left open to atmosphere but may be connected to a stable reference pressure. In an absolute pressure transducer this port is plugged. 8.5 Remote Communication Connections See Section 7, Remote Operation, for connections and commands for operation over IEEE-488, Ethernet, USB or RS-232 ports. 8.6 Power Up Apply power to the power connector on the rear of the instrument using the power adaptor included, and switch the power switch on the front of the unit ON. The instrument will go through an initialization process and system check. As soon as the system check is completed the system will default to a screen similar to the one shown in Section 6.1.2 - Display Screen Features. The main measurement screen may be configured in many different ways but initially it will be in a default configuration. Subsequently, the unit will power up in the configuration that it was in when last powered off. Allow at least 15 minutes of warm up before performing critical pressure measurements. Operating Instructions - CPG2500 21 Precision Pressure Indicator CPG2500 LVDS 24 bit DISPLAY/TOUCH PANEL DISPLAY LVDS INTFC 18 bit +5V BKLT INTFC 4 PORT USB HUB 4 PORT RS232 HUB CP2108 ETHERNET PORT 2 TOUCH INTFC USB HOST FRONT +12V PWR SWITCH 2x20 HEADER +5V DC POWER CONVERTER GPIB TNT488 RS232 COM PORT pic (/dev/tty 02) ADAPTOR BOARD 18976 USB PORT GPIB PORT USB DEVICE PORT BARO PORT (/dev/tty USB4) XDR #1 PORT (/dev/tty USB1) XDR #2 PORT (/dev/tty USB0) FUSE HOLDER DC POWER INPUT JACK +9 TO 28 VDC GND REMOTE XDR PORT REAR PANEL (/dev/tty O0) (/dev/tty USB3) (/dev/tty USB2) FRONT PANEL USB HOST PORT 2x20 HEADER EMBEDIAN PCBA 4904000084 CONSOLE PORT (/dev/eth 0) ETHERNET PORT 1 ETHERNET PORT +12 VDC POWER POWER GND TX 1 RX 1 +12 VDC POWER POWER GND TX 1 RX 1 BARO REF (USB) TRANSDUCER #1 ANALOG OUTPUT PCBA TRANSDUCER #2 ANALOG OUTPUT PCBA ANA OUT - ANA OUT + ANA OUT - ANA OUT + REAR PANEL CONNECTION REAR PANEL CONNECTION Operating Instructions - CPG2500 22 Electrical Block Diagram 8.7 Figure 5.7 - Electrical Block Diagram SMARC INTFC Precision Pressure Indicator CPG2500 9 Local Operation and Setup 9.1 General Operation This section describes the procedures for operating the CPG2500 from the front panel. Instructions for operating the device remotely from an external computer are covered in Section 7, Remote Operation. By following the procedures provided in these two sections and Section 10, Calibration, you can expect your CPG2500 to deliver maximum accuracy and dependability for many years of useful service. 9.1.1 Setup Applications Configuration of the CPG2500 is achieved by changing settings accessed through the Application (“App”) buttons. Local operation is accomplished by observing the data presented in the display. The appearance and functionality of the display can be changed by pressing the App button for the related function. After an app has been chosen, a set of related parameters will appear on the left. After choosing one of these parameters, a set of selections related to that parameter will appear on the right or a data entry keypad. The desired selection or data can be entered here. 9.1.2 Display Screen Features The screen shown below provides a brief description of the features shown on a 2 channel display after initialization. The left two thirds of the display contains the area where information is displayed (in this case the Measure Application) and the right one third contains the selection icons for each application. Channels are color coded: Channel A is green, B is blue, C (remote) is red and the barometer is sky-blue. Color coding persists throughout all channel-specific screens. A zero or tare button and auxiliary displays (auxiliary units, rate and peak) will appear in the Measure App if activated. All of the CPG2500 screen features are described in more detail throughout this manual. Range Reading Pressure Units and Mode App Display / Parameter Selection App Selection / Data Entry Figure 6.1.2 - Display Screen Features Operating Instructions - CPG2500 23 Precision Pressure Indicator CPG2500 9.2 Initial Setup Section 6.2.1 and 6.2.2 are provided first so that the operator can initially check the information screen to verify the installed components and to change the language if needed. 9.2.1 Contact and Version Information Application Press this application button to display Mensor contact, installed sensor, instrument and software version information. Figure 6.2.1 - Information 9.2.2 Language Selection Pressing the settings application button will open a screen where the language, display brightness, volume, user base units/multiplier and configuration loading/saving, can be changed. The current language selections available are shown in the table below. Additional language choices will appear on the screen after pushing the Page Down button [ ]: Language Country German Germany English French Spanish Italian Chinese English German French Spanish Russian Korean English French Polish Japanese 24 USA France Spain Italy China Great Britain Switzerland Switzerland Mexico Russia Korea Canada Canada Poland Japan Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 9.3 Application Selection and parameter inputs The application selection area on the right one third of the screen (see Figure 6.1.2 - Display Screen Features) is the area where setup, information and calibration Apps can be chosen. A second and third page of application selections can be accessed by pressing the page down button [ ]. A series of vertically placed circles on the center right indicates the active page by a larger circle. As each App is chosen, related application parameters will appear on the left two thirds of the screen along with the name of the application, and a reduced size icon in the top title section . When a parameter is chosen, related selections, sliding scales or a data entry key pad will appear in the input area on the right where the application selection buttons were previously displayed. An example of each type of input is shown below. To return to the App selection menu, simply press the menu button [ ] above the input area. The purpose and use of each selection and menu is intuitively apparent and will become second nature with minimal exposure to the menu structure. App Title Menu Button Input Title Page Down Operating Instructions - CPG2500 25 Precision Pressure Indicator CPG2500 9.4 Applications: 9.4.1 Measure Application The Measure App is the normal operation screen referred to in previous instruments as the ‘main screen’. This application is different from the others in that it is not use to setup the configuration but is used to monitor the pressure applied to the installed transducers. The screen in figure 6.4.1-A shows the basic Measure App in a three channel instrument. The units button is always present in each channel. When the units button is pressed a selection of imperial and metric units will be displayed on the right (figure 6.4.1-B); notice that the Units button has a lighter background when the selection menu is active. Any unit of measure can be selected for any channel. If a barometric reference is installed, the Mode button, described below, will toggle from Gauge to Absolute mode when pressed. Units Button Figure 6.4.1-A Basic Measure App Mode Button Figure 6.4.1-B - Units Change 26 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 9.4.1.1 Pressure Mode / Emulation Mode The Mode button is only active if there is an optional Barometric reference installed. Otherwise, the mode button becomes a label (figure 6.4.1.1-A) indicating the native mode of the transducer (absolute or gauge) and disappears when the “% of range” units are selected (figure 6.4.1.1-B). When an optional barometric reference is installed, a native gauge transducer can emulate absolute pressure using the barometric reference. Alternatively, a native absolute transducer can emulate gauge pressure. Emulation can be activated simply by pressing the Mode button. Without a Barometer the Mode button becomes a label Figure 6.4.1.1-A - Mode Label Figure 6.4.1.1-B - No Mode Button in “% of range” Operating Instructions - CPG2500 27 Precision Pressure Indicator CPG2500 9.4.1.2 Auxiliary Displays The screen in figure 6.4.1.2 shows all of the possible auxiliary display items that can be included in the Measure App, in addition, each channel can contain one of two possible calibration functions. The auxiliary display item includes “Alternate Units”, “Peak” and “Rate”. Calibration functions are either a “Zero” button or a “Tare” button. These auxiliary features will appear in the Measure App when selected from the Transducer App (section 6.4.4.4). Figure 6.4.1.2 - Three channel Measure App with auxiliary displays Auxiliary buttons can be placed in three different parts of the screen depending on how they are set in the Transducer Application. Each auxiliary display can be modified by pressing the displayed button. Peak: Pressing the Peak button will reset the upper and lower peak value to the current reading, subsequent negative or positive divergence from that reading will be recorded in the button. Rate: Pressing the Rate button will display a choice of rate time units for the rate denominator. Units: Pressing the Auxiliary Units button will display the same set of units available for the primary units. To change auxiliary units (ie. bar to psi), press the auxiliary unit you want to change and select which unit you want displayed. Figure 6.4.1.3 - Rate selected and unit options displayed 28 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 9.4.1.3 Zero Button If the Zero Calibration function has been chosen in the Transducer App (section 6.4.4), then the Zero Cal Button [ ] will appear in the Measure App. If the channel is measuring absolute pressure, and the Zero Cal Button is pressed, a keyboard will appear to allow a single point calibration. If the channel is measuring gauge pressure, pressing the button will set the current reading to zero. If the channel is in emulation mode (absolute or gauge) then the value will not be saved to the sensor but only as a temporary adjustment while in emulation mode. After exiting the emulation mode or after a power cycle, the temporary adjustment will be cleared. The zero adjustment for a channel not in emulation mode will be saved to the sensor as if single point calibration had been performed. Figure 6.4.1.4 shows two channels displayed, the zero cal function has been enabled for both channels. The screen on the left shows both channels with zero buttons. The screen on the right shows the same two channels, but the zero button on the absolute channel has been pressed, showing the keypad enabled to accept a new single point calibration value. Figure 6.4.1.3-A - Zero Button, Gauge Figure 6.4.1.3-B - Zero Button, Absolute The background color of the zero button will momentarily change to a lighter color as the zero calibration is performed then will revert back to a darker color when complete. Operating Instructions - CPG2500 29 Precision Pressure Indicator CPG2500 9.4.1.4 Tare Button If the Tare calibration function has been chosen in the Transducer App (section 6.4.4), then the Tare Button [ ] will appear in the channel screen. The Tare button and the Zero Button cannot appear on the screen at the same time, in the same channel. When the Tare button is pressed, the instrument will subtract the current pressure reading (the tare pressure) so that the indicator will display zero. Subsequent deviations in pressure will be relative to the tare pressure. Notice in the figure below that, when inactive, the back ground of the tare button is the same as the channel background, when active the button it is highlighted in yellow [ ] to distinguish an active tare value. . Tare button, inactive. Tare button, active. Figure 6.4.1.4 - Tare Button Pressing the tare button again will deactivate the tare and change the pressure indication back to the reading corresponding to the calibrated output of the transducer. An active tare will revert to a deactivated state after a power cycle. 30 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 9.4.2 Settings Application The Settings App is used to set up general settings for the display. Settings parameters include Language, Brightness, Volume, User 1 base units, User 1 multiplier, User 2 base units, User 2 multiplier, Barometer units, and Configuration. Figure 6.4.2 shows these parameters as indicated when the Settings App has been chosen. As each parameter is pressed, an input screen will appear on the right where selections can be made. The Settings App provides a place to change the language, display brightness, volume, user units, and barometer units. Configuration settings of the unit can also be saved within this application plus the default configuration can be activated. Figure 6.4.2 - Settings application 9.4.2.1 Languages The Language parameter provides a selection of different languages. Once a language is chosen all words within all menus will appear in the chosen language and the radix character (decimal mark) will change from a dot (.) to a comma (,) depending on the language chosen. Figure 6.4.2.1 - Languages Operating Instructions - CPG2500 31 Precision Pressure Indicator CPG2500 9.4.2.2 Brightness The Brightness setting provides a sliding scale to increment the screen brightness in all screens. Sliding your finger along the bar graph or touching anywhere in the bar graph will change the brightness of the screen. After the setting is made and your finger is removed from the screen the menu will revert back to the basic settings menu. Figure 6.4.2.2 - Brightness 9.4.2.3 Volume The Volume setting provides a way to turn on or off the touch screen audio feedback. Figure 6.4.2.3 - Volume 32 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 9.4.2.4 User base units / Base units multiplier When choosing a unit of measure from the Measure Application (main screen), standard units can be chosen in addition to two user defined units. User units 1 and 2 are defined in the Settings App using “User 1 base units”, “User 1 multiplier” and / or “User 2 base units”, “User 2 multiplier”. For example, if the display of one atmosphere (atm) was needed, then psi could be chosen as the “User 1 base unit” and the “User 1 multiplier”, in this case, would be 0.068045. When set this way and the user 1 unit has been chosen, the user 1 unit will now display the pressure in atm. Figure 6.4.2.4 - User base units / Base units multiplier 9.4.2.5 Barometer Units When the Barometer Units Parameter has been chosen, a list of Imperial or Metric units is presented on the right side of the screen. Any of these units can be chosen from this list for the barometric readout that can be seen on the bottom right of the Measure App. Figure 6.4.2.5 - Barometer units Operating Instructions - CPG2500 33 Precision Pressure Indicator CPG2500 9.4.2.6 Configuration Configuration is the last parameter in the Settings App. It allows the operator to save instrument settings and load them, as needed, in the future. Parameters that are set in the Settings App, the Frames App, the Transducer App, and the Remote App can be saved using the Configuration “Save” button and recalled using the Configuration “Load” button. Simply set all desired parameters then go to Settings-Configuration, press one of the numbered Configuration buttons then press the “Save” button. This will save the current configuration in that button. To reload a saved configuration at a later time, go to Settings-Configuration and press the numbered configuration button corresponding to the saved configuration and then press the “Load” button. Figure 6.4.2.6 - Configuration The instrument default configuration can be activated simply by pressing the “Default” Button. 34 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 9.4.3 Frames Application The Frame App allows the user to select the number and order of the transducer channels displayed in the Measure Application. A total of three channels can be displayed at a time. Typically, if two internal transducers and one external transducer are installed the display will include three channels: A, B and Remote, in order form top to bottom. The order and number of channels displayed can be defined in the Frames Application. In addition the optional barometric reference transducer can be displayed as a channel as well as an emulated Delta channel. Figure 6.4.3 shows the unit in dual frame format with the Frame Format set to display the readings from two transducers (A & B in a dual frame mode). Figure 6.4.3 - Frames Application 9.4.3.1 Frame Format The Frame format button sets the display in the Measure Application to Single Frame, Dual Frame or Triple Frame. Figure 6.4.3.1 shows the available selections for the Frame Format parameter. Figure 6.4.3.1 - Frame Format Operating Instructions - CPG2500 35 Precision Pressure Indicator CPG2500 9.4.3.2 Frames Channel The channel setting in the Frames application provides a way to choose which channel(s) appears and in what order within the Measure Application (Main Screen). Any installed transducer channel or the emulated Delta channel can be displayed in the Measure Application. In figure 6.4.3.2, the Dual Frame format is set in the Frames format parameter, channel A is set as the top frame and Channel B is set as the bottom frame. Channels A, B, Remote or Barometer could be placed in any available position. If the Single or Triple frame format is chosen then the channels will appear as shown in each of the respective frame position sets. Frame positions sets: Single Frame Dual Frame Triple Frame Resulting view in the Measure Application Figure 6.4.3.2 - Frames Channel In Figure 6.4.3.2-A, the Channels have been set in order for each frame format and the frame format has been set to “Frame triple”. In the Measure App the resulting channel position will be: channel “A’ on top, Channel “B” in the middle and the “Delta” channel on the bottom. The barometer reading (if installed) will appear as a selectable channel and will always be in the bottom right under the application menu. Figure 6.4.3.2-A - Example channel frame settings 36 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 9.4.4 Transducer Application For each transducer, the Transducer Application provides a way to set the filter for the reading to reduce fluctuations due to electrical noise, and to set the resolution of the reading. In addition, the auxiliary display functions and calibration function can be specified here. Figure 6.4.4 - Transducer Application 9.4.4.1 Transducer Channel Selection To set the transducer parameters, the transducer channel must be selected. Transducer parameters are identical for all channels but can be set differently in each channel. Figure 6.4.4.1 shows two displays where channel “A” and “B” have been selected. Figure 6.4.4.1 - Transducer Channel Selection Operating Instructions - CPG2500 37 Precision Pressure Indicator CPG2500 9.4.4.2 Transducer Delta Emulation If there is more than one transducer installed, the Delta Channel option will appear as a selection in the Transducer App. The Delta channel has all of the regular transducer parameters aside from the cal function in addition to the Delta Function shown at the bottom of Figure 6.4.4.2. When the Delta Function is selected settings will appear that define the delta display (in the Measure App). All discrete combinations for adding or subtracting one channel from another are available as a selection. These combinations are shown below in Figure 6.4.4.2. Figure 6.4.4.2 - Transducer Delta Emulation 9.4.4.3 Transducer Filter The Filter is an electronic filter to smooth out the pressure readings. Because of differences in resolution, greater filtering may display a more stable reading for some pressure units. Turn off the Filter by selecting “Off”, select varying degrees of filtering for the current units by selecting “Low”, “Normal” or “High”. Figure 6.4.4.3 - Transducer Filter 38 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 9.4.4.4 Transducer Resolution The resolution of each transducer channel can be set in the Transducer Application using the resolution parameter. The resolution can be set to 4, 5, 6 or 7 digits. Figure 6.4.4.4 - Transducer Resolution Operating Instructions - CPG2500 39 Precision Pressure Indicator CPG2500 9.4.4.5 Auxiliary Displays The Transducer Channel Auxiliary Display(s) can be set in the Transducer App by selecting Auxiliary Display 1, 2 or 3 and selecting from, None, Peak, Rate or Units. Figure 6.4.4.5-A shows auxiliary display 1, 2 and 3 set for units, peak and rate respectively. Auxiliary displays will appear in the Measure App as seen in Figure 6.4.4.5-B. Figure 6.4.4.5-A - Transducer channel aux displays set to Units, Peak and Rate Figure 6.4.4.5-B - Auxiliary displays as seen in the Measure App 40 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 9.4.4.6 Cal Function The Transducer Cal Function presents a choice of None, Tare or Zero. Choosing Zero will enable the Zero Cal Button [ ] in the Measure App. Choosing Tare will enable the Tare Button [ ] in the Measure App. The Tare button and the Zero Button cannot appear on the screen at the same time, in the same channel. See section 6.4.1.3 and 6.4.1.4 for operation of the Zero and Tare buttons in the Measure App (main screen). Figure 6.4.4.6 - Cal Function Operating Instructions - CPG2500 41 Precision Pressure Indicator CPG2500 9.4.5 Remote Application With the remote application you can select the remote command set for all interfaces. The GPIB address, Ethernet network parameters and Serial parameters can also be set here. Details about the Remote Operation (command sets, cable requirements, etc.) can be found in Section 7, Remote Operation. IEEE-488 Ethernet Serial RS-232 or USB Figure 6.4.5 - Remote Application 9.4.5.1 Remote Command Set The remote command set parameter provides a choice of the Mensor command set or the WIKA SCPI command set. Both sets of commands are listed in Section 7, Remote Operation. Figure 6.4.5.1 - Remote Command Set 42 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 9.4.5.2 Remote Communication Settings The remainder of the Parameters in the Remote Application present the choice of a numeric entry, a numeric address entry, or a radio button selection. The parameters that require a numeric entry will present a numeric keypad with min and max limits for the variable. The parameters that require a numeric address (for example an IP address) will also present a keypad. Address entries should conform to the format of the parameter selected. The three screens below show examples of each type. Numeric entry Numeric address entry Radio button selection i Setting the Ethernet DHCP to yes will have a short delay while the DHCP server is contacted. If a DHCP server is not found, an error will be indicated. If DHCP is enabled, the IP address, Netmask and Gateway are greyed out and locked, these are controlled by the DHCP server. Figure 6.4.5.2 - Remote Communication Settings Operating Instructions - CPG2500 43 Precision Pressure Indicator CPG2500 9.4.6 Info Application The Info application displays information about the instrument, including: • Mensor address, and email • Model number, serial number and operating software version. • Sensor model number, serial number, range, software version Figure 6.4.6 - Info Application 44 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 9.4.7 Leak Test Application The Leak Test application provides a way to check the system for leaks into or out of the system. This App is found on the second page of the Apps menu accessed by pressing the page down button [ ]. The operator defines a leak by setting the Time parameter and the Delta parameter. With the system pressurized to a predetermined amount, the leak test is initiated by pressing the Start button. If the change in pressure exceeds the Delta parameter before the allotted time in the Time parameter, then the Leak Test App will return a red status indication showing the actual difference (delta) in pressure recorded during time period set in the leak test, indicating a “failed” test. Otherwise it will return a green status indication showing that the delta was not exceeded for the time period, indicating a “passed” test. The Leak Test App also provides information on the initial, final and delta pressure change in a tabular form next to the active pressure reading. See Figure 6.4.7-A for examples of a failed and a passed test. Figure 6.4.7 - Leak Test Figure 6.4.7-A - Leak test fail (left) & Leak test pass (right) Operating Instructions - CPG2500 45 Precision Pressure Indicator CPG2500 9.4.8 Troubleshooting Application The Troubleshoot Application will display information about error conditions and remote communications. Within the troubleshoot screen (Figure 6.4.8-B), push the Error button to display any errors that have occurred in the instrument due to a communication or network error. Push the Remote button to show commands and responses that have been sent over the remote communication connection. If there are any errors in the error queue an error symbol [ ] will appear in all screens (Figure 6.4.8A) of the instrument. Pressing this error button from any screen will open the Troubleshoot application where the error can be viewed. Figure 6.4.8-A - Error indication Figure 6.4.8-B - Troubleshoot error and remote 46 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 9.4.9 Logging Application The logging application enables real-time storage of current instrument output and state in a USB device plugged to the front panel of the CPG2500. The application also provides a means to log any remote communication (commands and responses) to the instrument. The primary objective of this application is to provide test data for troubleshooting purposes. i Note: The Logging Application is only visible when a compatible USB device is plugged to the front panel of the CPG2500. The Application is greyed out in the absence of a USB device. Figure 6.4.9-A Logging Application with USB (left) and without USB (right) 9.4.9.1 Remote Logging The queries and responses sent over the remote communication can be logged on to the USB device using the remote logging feature. This feature allows monitoring communication and any erronous responses from the instrument. The logging can be started by pressing the “Start” line, this would bring a keypad on the screen (Figure 6.4.9.1) for entering the file name to store the logging data. The extension of this file is set to “.txt” by default. Click [ ] to exit the keypad. This will automatically generate the file on the USB device and start logging the remote commands. The log function continues to run in the background while the instrument is operated locally or remotely. To stop logging, press the “Stop” line. Figure 6.4.9.1 File Name Keypad Operating Instructions - CPG2500 47 Precision Pressure Indicator CPG2500 9.4.9.2 Pressure Logging The Logging App allows the storage of the time interval, active pressure and rate reading from all channels of the instrument to a file. The “File format” button provides selection of “.DAT” or “.CSV” file type. The logging is started by pressing the “Start” line, entering a file name on the alpha numeric keypad (Figure 6.4.9.2-A) and clicking [ ]. The values are continuously written to the file until “Stop saving to” line is pressed (Figure 6.4.9.2-B). Figure 6.4.9.2-A File name keypad with “.csv” format Figure 6.4.9.2-B Pressure logging active i 48 Note: Once all the activity inside the Logging Application is over, press the USB icon in the top bar of display and click “Remove USB Device” to safely disconnect the USB device. Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 9.4.10 Service Application The service application is a password protected area where calibration of all connected sensors can be accomplished. In addition, this is where the password for entering this area can be changed. Figure 6.4.10-A - Service Application (locked) Press the Enter button to show the numeric keypad to enter a password. This will unlock other applications. Default password is 123456. Enter 123456 and press the check mark [ ] to unlock the Service Application. Figure 6.4.10-B - Service Application (Enter Password) i Note: The default Password is 123456. After entering this for the first time, the password can be changed. Operating Instructions - CPG2500 49 Precision Pressure Indicator CPG2500 9.4.11 Unlocked Service Application After the Password has been entered, the unlocked Service Application will appear (Figure 6.4.11). To re-lock this screen, press the lock button. Figure 6.4.11 - Unlocked Service Application From the Unlocked Service Application, the Password can be changed by pressing the Enter button next to the Change Password label. This will open a keypad where a new password can be entered and accepted by pressing the Check Mark [ ]. i ote: Please make note of a password change and save the new password in a secure N location. i Note: Recommended calibration setup and explanation of calibration screen applications is covered in Section 10 of this manual. The Unlocked Service Application is the access point to all calibration screens described in Section 10 of this manual. 50 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 NOTES Operating Instructions - CPG2500 51 Precision Pressure Indicator CPG2500 10 Remote Operation Use the screens in Section 6.4.5 Remote Application to set the operating parameters for the instrument command set, Ethernet, Serial (RS-232) and IEEE-488 (GPIB) information. 10.1 Command Set Command Set button – Users’ can select which model remote protocol they would like to emulate for simulation and testing purposes. Selections may include the following or may be added per customers’ specifications: • Mensor (default) • SCPI WIKA (The SCPI WIKA mode emulates the WIKA command set in SCPI format.) 10.2 IEEE-488 IEEE-488 address button – Allows the user to set the GPIB address by inputting a numeric value utilizing the touch screen. 10.2.1 IEEE-488.2 Commands Command or Query Response / Function *RST Reset to known state (default+psi) *IDN? *TST? *OPC *WAI *CLS *ESE *ESE? *ESR *ESR? *SRE *SRE? *STB? 52 Returns identification string Returns 1 Operation completed Returns operation completed state Clear status and error queue Enable status event Returns enable status even value Event status register Returns even status register value Service request enable Returns service request enable value Returns status byte Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 10.3 Ethernet The Ethernet function allows the user to set the following by inputting a numeric value in each separate field: • • • • • IP Netmask Gateway Port DHCP settings Set the Ethernet communication parameters as described in Section 6.4.5. ! Caution ! CAUTION: Please contact your network administrator for proper settings. CAUTION: Please consult your computer resources department prior to connecting this instrument to your network to verify there are no conflicts with existing IP addresses. Caution The Ethernet communication port allows the CPG2500 to communicate with computers using 10/100Based-T specifications. Before using Ethernet communication, four parameters must be set up: IP, Netmask, Gateway, and Port. Operating Instructions - CPG2500 53 Precision Pressure Indicator CPG2500 10.4 Serial Set the Serial communication parameters as shown in Section 6.4.5 Remote Application. The serial communication port allows the CPG2500 to communicate in RS-232 format with computers, terminals, PDAs, or similar hosts. These parameters should be set to match your host computer. Default settings are: 57600 baud, 8 data bits, 1 stop bit, no parity, and no echo. If echo is ON, the CPG2500 will immediately echo back characters sent over the serial port. The Serial function allows the user to set the RS-232 serial port settings by selecting from the choices provided: • Baud 9600 19200 38400 57600 115200 • Data Bits 7 8 • Stop Bits 1 2 • Parity Even Odd None • Echo settings On Off 10.4.1 Serial Cable Requirements RS-232 communications are transmitted over a three conductor, shielded cable terminated in a standard DB9 connector on the instrument end, and a different gender connector on the host end. The proper pinouts are shown in the following illustration. ! CAUTION: When replacing an older model DPG 2100, the serial cable should be replaced with a straight cable or a null-modem inserted in the line. Caution 54 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 10.5 Mensor Command Set This Mensor command set is the default on the CPG2500. For queries (ending with a ?), the Data column represents the response of the CPG2500. All response strings begin with a space character or an “E” representing that there is an error in the error queue. All response strings are terminated with a <CR> and a <LF>. The error queue holds the last 10 errors identified. For all commands (no ?), the data column represents the required parameters to be sent to the CPG2500 following the string in the command column. For any command that requires multiple parameters to be sent, the parameters must be separated by commas. 10.6 Command and Query Format Commands must be sent in ASCII format and terminated with either a carriage return (<cr>), linefeed (<lf>), or both. Commands are not case sensitive. Each query returns a response. If an error is detected the response will include an error flag. Command or Query field: Unless otherwise specified, commands are typically converted to queries by appending a question mark to the command. Table 7.9 lists all of the CPG2500 command or query keywords. Data field: The data field is either in ASCII {string} or numeric {value} form. In the case of multiple data fields, commas are required to separate the fields. Queries do not have a data field. String (text) or value (numeric) data are acceptable in any of the following formats: Examples of {string} data: ON, OFF, mBar, inHg Examples of {value} data: 1, 1.0, -5.678, 25.68324e-5 10.7 Command Set Definitions In this manual a data entry made up of alpha characters is defined as a string, as opposed to data containing only numbers, such as “Enter 1 for ON or 0 for OFF” where 1 and 0 are defined as values. Command: Any command or query listed in Table 7.9. For commands that take boolean data the following strings are acceptable: 0 False No Off 1 True Yes On Separator: Space (SP). Data: ASCII representations of numbers, {value}, or alpha characters, {string}, data as defined above. When sending code a literal variable replaces the brackets and the enclosed character(s) shown in the following examples. Termination: Linefeed (LF) or carriage return (CR) is used to signal the end of a command statement. For IEEE-488.2 operation “EOI” is an acceptable alternative. Always send commands in one of the following formats: 1. [Command] [Termination]; 2. [Command] [Separator] [Data] [Termination]; 3. Queries are special instructions in the form: [Command?] [Termination] where the question mark, “?”, immediately precedes the terminator. When a valid query is received, the CPG2500 will return {data} terminated by CR and LF. Floating point data is returned in the current engineering units in exponential format. Operating Instructions - CPG2500 55 Precision Pressure Indicator CPG2500 10.8 Output Formats Pressure readings are returned in exponential notation in a format according to the OUTFORM command as follows. Outform applies to both pressure channels. 1. <sp> pressure value <cr><lf> 2. <sp> pressure, units number,STANDBY <cr><lf> 3. <sp> pressure, pressure rate <cr><lf> 4. <sp> pressure, minimum peak, maximum peak <cr><lf> 10.9 CPG2500 Commands and Queries Table 7.9 lists all of the current CPG2500 commands and queries. i Notice Channel specific commands are sent to only the active channel. See ‘CHAN’ command. Optional emulation modes are available in which a CPG2500 can emulate remote functions of different brands of pressure gauges. Please contact Mensor for more details. Table 7.9 - CPG2500 Commands and Queries Command ? Data See Table Below A? <sp>n.nnnnne+nn<cr><lf> AB? <sp>n.nnnnnE+nn, ABCBaro? <sp>n.nnnnnE+nn, n.nnnnnE+nn<cr><lf> n.nnnnnE+nn, n.nnnnnE+nn, AR? Accuracyst? Acquire? ActualPress <n>, <f> 56 n.nnnnnE+nn<cr><lf> <sp>n.nnnnne+nn<cr><lf> <sp>ccccccccc<cr><lf> Ex: 0.010% IS-50 15 char string. Ex: Acquire? Test_stand_1 Returns: <sp>(YES or NO), CCC… CCC<cr><lf> n, f Response/Function Returns data per the current output format Returns the A channel pressure reading Returns A and B channel pressure readings. Returns Zero if no transducer is connected. Returns A, B, C, and Barometer channel readings. Returns Zero if no transducer is connected. Returns the A channel rate Returns the accuracy string of the sensor on the active channel. This command is used when multiple computers would like to control the instrument. Yes if acquisition is successful. No if instrument is being controlled with another computer. See: Release? and Unlock Set the linearity actual pressure for segmentn, where n is 0 to 10 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 ActualPress? <n>, <f> <sp>n.nnnnnE+nn<cr><lf> Address Address? Asset_tag 1-31 <sp>nn<cr><lf> 16 char string Auxdisp<sp><n>, <s> n, s Auxdisp?<sp><n> s Returns the linearity actual pressure for segment n, where n is 0 to 10 Sets the GPIB Address Returns the GPIB Address General purpose string for customer use. Sets the auxiliary display function where “n” is the auxiliary display to be set (1,2, or 3) and “func” is the function (none, peak, rate,units) Returns the auxiliary display function Brightness f Brightness? <sp>n.nnnnnE+nn<cr><lf> specified by “n” for the active channel Brightness f Set screen brightness between 0 and 100% Read the screen brightness Asset_tag? <sp>sssssssss<cr><lf> Return customer asset tag string B? <sp>n.nnnnnE+nn<cr><lf> BR? Baro? <sp>n.nnnnnE+nn<cr><lf> <sp>+n.nnnnnE+nn<cr><lf> C? <sp>n.nnnnnE+nn<cr><lf> Returns the B channel pressure reading Returns the B channel rate. Returns reading from barometric sensor or “NO BAROMETER” if one isn’t installed Returns the C channel pressure reading Returns the C channel rate Calculate linearity slopes and intercepts from true/actual pressures Sets whether or not the ability to calibrate the sensors is disabled Returns whether or not the ability to calibrate the sensors is disabled Returns the calibration interval in days for the sensor on the active channel Clears the error queue Set the certificate string for the sensor on the active channel Returns the certificate string for the sensor on the active channel Sets the active channel Returns the active channel CR? <sp>n.nnnnnE+nn<cr><lf> Calculate_as_found_linearity Caldisable YES,NO Caldisable? <sp>(YES or NO)<cr><lf> Cal_Interval? <sp>nnn<cr><lf> Cerr Certificate None <sp>CCCCC…<cr><lf> Certificate? <sp>CCCCC…<cr><lf> Chan Chan? A, B, C, D <sp>X<cr><lf> Operating Instructions - CPG2500 57 Precision Pressure Indicator CPG2500 Chanfunc n, func<cr><lf> Chanfunc? <n> <sp>CCCCC…<cr><lf> Cmdset Mensor, SCPI Cmdset? <sp><CCCCC...<cr><lf> D? <sp>n.nnnnne+nn<cr><lf> DR? Decpt? Default Deltafunc Deltafunc? DHCP DHCP? DOC DOC? DOM? Error? Filter Filter? Gasdensity Gasdensity? Gastemp 58 Sets the auxiliary display function where “n” is the auxiliary display to be set (1,2, or 3) and “func” is the function (none, peak, rate, units) Returns the auxiliary display function specified by “n” for the active channel Activates remote command set for instrument emulation modes Returns active command set identifier Returns the D channel pressure reading <sp>n.nnnnne+nn<cr><lf> Returns the D channel rate <sp>n<cr><lf> Returns the number of decimal points (see Resolution) None Sets the default values A+B, A+C, B+C, A-B, A-C, B-A, B-C, Sets the delta to be the result of the C-A, C-B specified function <sp>CCC<cr><lf> Returns the delta function ON or OFF Reserved for DHCP setup <sp>(YES or NO)<cr><lf> Reserved for DHCP setup mm/dd/yyyy Sets the date of cal for the active channel’s sensor <sp>mm/dd/yyyy<cr><lf> Returns the date of cal for the active channel’s sensor <sp>mm/dd/yyyy<cr><lf> Returns the date of manufacture <sp> text description <cr><lf> Returns the next error in the error queue OFF, LOW, NORMAL, HIGH Sets the reading filter 0, 80%, 92%, 95% <sp> (filter)<cr><lf> Returns the reading filter Value in lb/cuft, or “NITROGEN” or Sets the head pressure gas density “DRYAIR” in lb/cuft. Only set for currently active channel. See alias command MEDIADENSITY <sp>+n.nnnnnE+nn<cr><lf> Gets the head pressure gas density in lb/cuft. Only set for currently active channel. See alias command MEDIADENSITY? Value in degrees Degrees in ∞F or ∞C depending on selected units category. See HEADUNITS? channel. See alias command MEDIATEMP Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 Gastemp? <sp>+n.nnnnnE+nn<cr><lf> Gateway Gateway? HeadChanAll nnn.nnn.nnn.nnn <sp>nnn.nnn.nnn.nnn<cr><lf> ON or OFF HEADUNITS METRIC/IMPERIAL/ENGLISH HEADUNITS? Height METRIC or IMPERIAL Value in inches Height? <sp>+n.nnnnnE+nn<cr><lf> Id? IP IP? <sp>MENSOR, CPG2500, ssssss, v.v.vv<cr><lf> nnn.nnn.nnn.nnn <sp>nnn.nnn.nnn.nnn<cr><lf> Instmode ssssssss Keylock YES or NO Keylock? <sp>(YES or NO)<cr><lf> Operating Instructions - CPG2500 Gets the head pressure gas temperature. Degrees in ∞F or ∞C depending on selected units category. See HEADUNITS?Only set for currently active channel. See alias command MEDIATEMP? Sets the Ethernet gateway address Gets the Ethernet gateway address When changing a head pressure correction setting, determines if the change applies to all channels, or only the currently active channel. When off, only applies to the active remote channel (see CHAN?). The head pressure correction setting include media density (see MEDIADENSITY?), media temperature (see MEDIATEMP?), and head height (see HEIGHT?). Sets head pressure units category to metric of imperial Sets head pressure units category Sets the head pressure height in inches Gets the head pressure height in inches ssssss is the serial number,v.v.vv is the CPG2500 software version Sets the IP address of the instrument Returns the IP address of the instrument Set the instrument mode to Airdata, Ps/Pt Pressure, Ps/Pt Pressure, Ps/ Pt, PsPt, Ps/Qc Pressure, PsQc, Ps, Pt, Qc, Altitude, Airspeed, or Pressure. Only valid for the CPA2501 Locks or unlocks the entire touch screen Returns Yes or No 59 Precision Pressure Indicator CPG2500 LANGUAGE XXXX LANGUAGE? LEAK_START LEAK_STOP LEAK_STATE? <sp>XXXX<cr><lf> LEAK_DWELL LEAK_DWELL? Value in seconds <sp>+n.nnnnnE+nn<cr><lf> LEAK_DELTA_LIMIT Values in current engineering units LEAK_DELTA_LIMIT? <sp>+n.nnnnnE+nn<cr><lf> LEAK_INITIAL? <sp>+n.nnnnnE+nn<cr><lf> LEAK_FINAL? <sp>+n.nnnnnE+nn<cr><lf> LEAK_DELTA? <sp>+n.nnnnnE+nn<cr><lf> Leak_pass_rate Leak_pass_rate? f <sp>+n.nnnnnE+nn<cr> LEAK_PASS? <lf> (YES or NO) List? Listcal? <sp>PRI,1<cr><lf> <sp>PRI, {sn},1,{mmddyy}<cr><lf> Listrange? ListSN? <sp>PRI,1,min,max<cr><lf> <sp>PRI,1,SSSSSSSS<cr<lf> Localgravity Localgravity? Value in ft/s^2 <sp>+n.nnnnnE+nn<cr><lf> 60 (IDLE,RUNNING,COMPLETE) Set the displayed language. String to be sent may be ENGLISH, ENGLISH GB, ENGLISH CA, GERMAN, FRENCH, FRENCH CH, FRENCH CA, SPANISH, SPANISH LA, ITALIAN, POLISH, PORTUGUESE, PORTUGUESE BR, RUSSIAN, JAPANESE, CHINESE, KOREAN Returns the displayed language Starts leak test Abort leak test Get the current state of the leak test. IDLE = test never run. RUNNING = currently running test. COMPLETE = test completed Set leak test dwell time Gets the leak test dwell time in seconds Set the leak test pass criteria for the allowable pressure change Gets the leak test delta limit in current engineering units Get the leak test initial pressure in current engineering units Get the leak test ending pressure in current engineering units Returns the delta pressure of the final minus the initial pressure. This value is compared to the delta pass rate limit to determine if the test passed or failed. Set the leak test pass rate limit Returns the leak test pass rate Get the leak test pass results, which is YES when the delta pressure is less than the delta limit Legacy query Returns the calibration date of the active sensor Returns the range of the active sensor Returns the serial number of the sensor on the active channel Sets the local gravity in feet/sec^2 Returns the local gravity in feet/sec^2 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 Loudness Integer 0 to 100 Loudness? <sp>NNN<cr> MACADDR? <lf> <sp>XX-XX-XX-XX-XX-XX<cr><lf> MEDIADENSITY Value, or ìNITROGENî or ìDRYAIRî MEDIADENSITY? <sp>+n.nnnnnE+nn<cr><lf> MEDIATEMP Value in degrees MEDIATEMP? <sp>+n.nnnnnE+nn<cr><lf> Netmask Netmask? OSVersion? Outform Outform? nnn.nnn.nnn.nnn <sp>nnn.nnn.nnn.nnn<cr><lf> <sp>n.n<cr><lf> 1 to 4 – see Section 7.9 <sp>X<cr><lf> Peakmax? <sp>n.nnnnnE+nn<cr><lf> Peakmin? <sp>n.nnnnnE+nn<cr><lf> Peakreset Port None nnnnn Port? <sp>nnnnn<cr><lf> Ptype Absolute or Gauge Ptype? <sp>CCCCC<cr><lf> Operating Instructions - CPG2500 Set the speaker volume to ON or OFF. Greater than 50 sets on, less than or equal to 50 turns off Returns the speaker volume, between 0 and 100 Returns MAC address for the instrument’s ethernet interface. Set the media density. If value is sent, lb/cuft while in Imperial units, and kg/ m^3 while in Metric units. See HEADUNITS? for units category. Returns the head pressure media density Sets the head pressure gas temperature (only applicable while media type set to Pneumatic). Value returned in corresponding degrees ∞F or ∞C depending on selected units category. See HEADUNITS? Gets the head pressure gas temperature (only applicable while media type set to Pneumatic). Value must be in corresponding degrees ∞F or ∞C depending on selected units category. See HEADUNITS? Sets the Ethernet network mask Gets the Ethernet network mask Returns the operating system version Sets the output format Returns the output format – see table below Returns the maximum pressure since peakreset was sent Returns the minimum pressure since peakreset was sent Resets the peak values. Sets the Ethernet port of the instrument Returns the Ethernet port of the instrument Sets the instrument pressure type – emulation only works if the optional barometric sensor is installed Returns “Absolute” or “Gauge” for the pressure type 61 Precision Pressure Indicator CPG2500 RangeMax? <sp>n.nnnnnE+nn<cr><lf> RangeMin? <sp>n.nnnnnE+nn<cr><lf> Rate? <sp>n.nnnnnE+nn<cr><lf> Rdecpt? <sp>n<cr><lf> Release? 15 char string. Ex: Release? Test stand 1 Returns: <sp>(YES or NO), CCC… CCC<cr><lf> Resolution <n> Resolution? <sp>n<cr><lf> Rfilter Rfilter? Value in % <sp>n.nnnnnE+nn<cr> <lf> SEC, MIN, HOUR, 3HOUR <sp>XXXX<cr><lf> Runits Runits? Save_cal Save_linearity Sbaud Sbaud? Sdata Sdata? Sensorid? Span Span? Sparity Sparity? Sstop 62 Returns the maximum range of the active transducer in the current units Returns the minimum range of the active transducer in the current units Returns the rate reading of the instrument in current units/current time unit (see: Runits) Returns the number of rate decimal points (see: Resolution) This command is used to release control of the instrument in a multiple computer environment. Yes if release is successful No if instrument is being controlled with another computer CCC… = name of controlling computer or AVAILABLE See: Acquire? and Unlock Sets the number of significant digits (see: decpt) Returns the number of significant digits (see: decpt) Sets the % of the rate filter Returns the rate filter Set the rate time units Returns the pressure per rate time units, i.e. BAR/SEC Save calibration values Save linearity values 9600, 19200, 38400, 57600, 115200 Sets the serial baud rate <sp>XXXX<cr><lf> Returns the serial baud data 7 or 8 Sets the serial data bits <sp>n<cr><lf> Returns the serial data bits number <sp>Mensor,SN XXXXXX, VN.NN Returns the active sensor’s serial number and firmware version desired pressure or ? Sets span on active transducer or for ?, clears previous value, must be > 50% FS and has a 1% limit. CALDISABLE must be OFF/NO. <sp>XXXXXXX<cr><lf> Returns span scale factor for active transducer Even, ODD, NONE Sets the serial parity <sp>CCCC<cr><lf> Returns the serial parity 1 or 2 Sets the serial stop bits Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 Sstop? SUBUNITS? <sp>X<cr><lf> <sp>XXXX<cr><lf> Tare Tare? Transfer_factory_to_linearity Units Units? ON / OFF <sp> n.nnnnnE+nn <cr><lf> Unlock None Window Value in current units Window? <sp>n.nnnnnE+nn <cr><lf> desired pressure or ? Zero Zero? units code or text in table below <sp>CCCC<cr><lf> <sp>n.nnnnnE+nn <cr><lf> Returns the serial stop bits Returns the instrument auxiliary display units in a text string Tares the reading to zero Returns value of Tare Copy factory linearity coefficients to customer Sets the instrument engineering units Returns the instrument units in a text string Releases Acquire locks (see: Acquire? ) or (see: Release?) Sets the exponential filter window for the active sensor Returns the exponential filter window for the active sensor Sets zero to set pressure or for ?, clears previous value. CALDISABLE must be OFF/NO Returns zero offset for active transducer Note: Except for the engineering units selection, the numeric suffix selects the applicable channel/sensor: 1 = Channel A 2 = Channel B 3 = Channel C 4 = Channel D 5 = baro (if installed) This numeric suffix always defaults to 1 and is designated by [C] (channel) Operating Instructions - CPG2500 63 Precision Pressure Indicator CPG2500 10.9.1 Units Command Syntax for Measurement Units n Description Output Format Type 2 inches of mercury @ 0°C INHG Imperial 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 32 33 34 36 37 38 39 64 pounds per square inch inches of mercury @ 60°F inches of water @ 4°C inches of water @ 20°C inches of water @ 60°F feet of water @ 4°C feet of water @ 20°C feet of water @ 60°F millitorr inches of sea water @ 0°C feet of sea water @ 0°C atmospheres bars millibars millimeters of water @ 4°C centimeters of water @ 4°C meters of water @ 4°C millimeters of mercury @ 0°C centimeters of mercury @ 0°C torr kilopascals pascals dynes per square centimeter grams per square centimeter kilograms per square centimeter meters of sea water @ 0°C ounce per square inch pounds per square foot tons per square foot micron of mercury @ 0°C tons per square inch hectapascals megapascals millimeters of water @ 20°C centimeters of water @ 20C meters of water @ 20°C PSI INHG Imperial INH2O Imperial INH2O Imperial INH2O FTH2O FTH2O FTH2O MTORR INSW FTSW Imperial Imperial Metric Imperial Metric MBAR MMH2O CMH2O MH2O MMHG Metric Metric Metric Metric Metric CMHG Metric TORR Metric KPA Metric PA DY/CM2 2 2 MSW OSI PSF TSF mHG TSI HPA MPA MMH2O CMH2O MH2O Imperial Imperial BAR KG/CM Imperial Imperial ATM G/CM Imperial Metric Metric Metric Metric Metric Imperial Imperial Imperial Metric Imperial Metric Metric Metric Metric Metric Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 10.9.2 CPG2500 Error Codes Code Serial Poll Byte Description Error String Returned E05 45h Parameter error EGPIB PARAMETER ERROR: String that was sent E00 E07 00h 47h No errors Syntax error NO ERRORS EGPIB SYNTAX ERROR: String that was sent 10.9.3 SCPI Commands and Queries OUTPut STATus :CHANnel :CHANnel? :OPERation :CONDition? MEASure Set the active channel to A, B, C, or BARO Returns the active channel Returns an integer value representing instrument status that can be decoded. Bit 0: Zeroing activ Bit 1: Control Setpoint has not been reached. Bit 2: Reserved 0. Bit 3: Reserved 0. Bit 5: Measuring. The instrument is actively measuring [:PRESsure][C]? Returns the pressure from Channel [C] :RATE[C]? Returns the rate/sec from Channel [C] :TEMPerature[C]? :BAROmetric? CALibration [:PRESsure][C] Returns the temperature from Channel [C] Returns the barometric pressure :MODE? Returns 1=calibrated or 0=not calibrated :DATE <i,i,i> Sets date of cal YYYY,MM,DD :DATE? :ZERO? :ZERO <n> :ZERO:INITiate SENSe [:PRESsure][C] Returns date of cal “MM/DD/YY” Returns zero offset Sets the zero offset Ignored :NAME? Returns sensor name string :MODE ABS|GAUGE Sets pressure type :MODE? :ABS? :RESolution? :RANGe [:UPPer]? :LOWer? :UNIT [:NAME]? Operating Instructions - CPG2500 Returns “ABSOLUTE” or “GAUGE” Returns native sensor type 0=GAUGE 1=ABSOLUTE Returns resolution (float) Returns maximum range Returns minimum range Returns ASCII units (mixed case) 65 Precision Pressure Indicator CPG2500 :VALue? Returns the units conversion factor [:HEIGht] <n> Sets the head pressure height in cm :MODE? Returns “OFF”, “GAS”, or “LIQUID” :REFerence :HEIGht? :MODE OFF | GAS | LIQUID :MEDium<n> :MEDium? :ACTive <C> SYSTem ACTive? Returns medium Sets the active channel Returns the active channel :DATE <i,i,i> Not used, kept for backwards compatibility :TIME <i,i,i> :TIME? :ERRor[:NEXT]? :KLOCk ON | OFF | 1 | 0 :LANGuage? :PRESet :SAVe :VERSion? Returns the active channel Not used, does not cause an error, does not return a response Not used, kept for backwards compatibility Not used, does not cause an error, does not return a response Returns error code, description Sets the keylock state Returns the active displayed language Load known state values No function (not needed) Returns SCPI version 1994.0 :ELECtronic? Returns “OK” :[PRESsure] bar | mbar | Pa | psi Sets the pressure units :NAME<n>? Returns the units string for units code <n> :[PRESsure]? :FACTor <n>? :INDEX <n> 66 Sets the medium density Sets the active channel to A, B, C, or BARO :DATE? UNIT Sets the head pressure mode :CHANnel :CHANnel? TEST Returns the head pressure height in cm Returns the pressure units Returns the units conversion for units code <n> Sets the index number. Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 :INDEX? Operating Instructions - CPG2500 Returns the index number. index unit 0 bar 1 mbar 2 Pa 3 psi 4 atm 5 kp/cm2 6 lbf/ft2 7 kPa 8 cmH2O(4°C) 9 inH2O(4°C) 10 inH2O(60°F) 11 ftH2O(4°C) 12 µmHg(0°C) 13 mmHg(0°C) 14 cmHg(4°C) 15 inHg(0°C) 16 inHg(60°F) 17 - 18 user 19 user 20 user 67 Precision Pressure Indicator CPG2500 10.9.4 SCPI Commands Error Messages and Error Codes All remote commands sent to the CPG2500 are shown in the Trouble Shooting App, under the “Remote” button. If there is a syntax error, an error message will appear below the errant command. Local errors and remote command errors will appear under the “Error” button. Maximum of 100 errors are stored and can be retrieved. 10.9.5 GPIB Capability Codes SH1 AH1 T6 L4 SR1 L1 PO DC1 DT1 C0 E2 Full source handshake capability Full acceptor handshake capability Talker with serial poll and unaddress if MLA Listener with unaddress if MTA Full service request capability Full remote/local capability including LLO No parallel poll capability Full device clear capability Full device trigger capability No controller capability Tri-state outputs 10.9.6 Interface Functions The CPG2500 responds to the following IEEE.488.2 interface functions: SRQService Request: A service request is asserted whenever an error is encountered. When the bus controller issues a serial poll the error will be cleared. If the host IEEE board includes automatic serial polling capability, turn this feature off in order to view all errors. LLOLocal Lockout: The front panel keyboard of the CPG2500 may be locked by sending LLO or the command KEYLOCK ON. GETGroup Execute Trigger: When this message is received, the CPG2500 will save the current readings until the next time it is addressed as a talker. GTLGo To Local: A GTL message will cause the CPG2500 to return to local operation and unlock the keyboard. DCLDevice Clear: When this message is received, the CPG2500 will clear all errors and buffers and remain in the Remote mode. SDCSelected Device Clear: The effect is the same as DCL. EOIEnd or Identify: May be used as a command or query terminator in the place of, or concurrent with, a terminating linefeed. 68 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 10.10 USB Software Upgrade The instrument software can be upgraded to the most recent release by copying the instrument software from the Mensor website onto a USB device. The instrument software is device specific and the software for any other instrument apart from the CPG2500 is not accepted by the instrument. The user can then plug the USB device to the USB port on the front panel of the instrument for an easy upgrade. The instrument recognizes this device by displaying a USB icon on the top bar of the screen. The user can navigate to the Software upgrade menu by clicking on the USB icon. The software upgrade menu gives the user information on the current instrument software and the version of instrument software on the USB device (figure 7.10-A). The user can load the instrument software from the USB to the instrument by clicking on the desired version and then clicking [ ] button. The status of the installation can be seen on right one fourth of the screen (figure 7.10-B). Figure 7.10-C shows how to safely remove the USB drive. Figure 7.10-A – Software Upgrade Menu Figure 7.10-B – Loading Software Operating Instructions - CPG2500 Figure 7.10-C – Remove USB Device 69 Precision Pressure Indicator CPG2500 NOTES 70 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 11 • • • • • • • • Options Barometric Transducer Channel Barometric Reference (for gauge and absolute emulation) External Transducers (CPT9000, CPR2510, CPT6100 and CPT6180) External Sensor Package (rear plate with D-Sub and cable) Analog Output Rack Mount Kit Fittings Remote calibrations sleds (transducers, Barometric reference) 11.1 Barometer The CPG2500 can be ordered as a single range Barometer. It is a very stable, absolute pressure sensor, used to accurately measure local atmospheric pressure. The only significant difference between a barometer and a regular transducer is that the transducer in a Barometer is calibrated from 8 to 17 psia and has an accuracy of 0.01% of reading. The channel setup information as explained in this manual also applies to the Barometer. It cannot, however, be used as a barometric reference for Gauge or Absolute emulation. 11.2 Barometric Reference (CPX-A-G1-3-J of CPX-A-G1-3-D) The Barometric Reference Transducer is an absolute pressure sensor used to accurately measure local atmospheric pressure. This sensor is in a different housing compared to the regular transducers. It is removable by taking off the top cover of the chassis. The CPG2500 uses the barometric pressure, measured by the barometric reference, for pressure mode emulation in the internal and external transducer channels. If a barometric reference is installed the Pressure Mode button in the measure application (main screen) will become active and, when pressed, will toggle between Absolute and Gauge mode (See section 6.4.1 Measure Application). 8.1.1 Gauge Pressure Emulation In the Measure Application (main screen) an absolute transducer channel will indicate “Absolute” in the mode button (this is the default mode). When this button is pressed the button label will toggle to “Gauge” and have a lighter background color. The lighter background color is an indication that the channel is in emulation mode. In the gauge emulation mode the atmospheric pressure reading from the barometric reference transducer is subtracted from the absolute pressure reading of the channel to emulate a gauge pressure. The barometric reference sensor has six significant digits. If a very low pressure gauge sensor is active and is used in absolute emulation, the combined output may appear quite noisy because of the resolution of the barometric reference. 11.2.1 Absolute Pressure Emulation In the Measure Application (main screen) a gauge transducer channel will indicate “Gauge” in the mode button (this is the default mode). When this button is pressed the button label will toggle to “Absolute” and have a lighter button background color. The lighter background color is an indication that the channel is in emulation mode. In the absolute emulation mode the atmospheric pressure reading from the barometric reference transducer is added to the gauge pressure reading of the active channel to emulate an absolute pressure. Operating Instructions - CPG2500 71 Precision Pressure Indicator CPG2500 11.2.2 Emulation Mode Accuracy The accuracy in emulation mode is the combined accuracy of the transducer and the barometric reference. 11.2.3 Barometric Reference Calibration The Barometric Reference Transducer can be calibrated in exactly the same manner as the other installed sensors as described in Section 10, Calibration. 11.2.4 Barometric Reference Specifications Accuracy: 0.01% of reading. Uncertainties include all pressure effects, temperature effects over the calibrated range and calibration stability for 365 days after re-zeroing. Pressure Range: The standard Barometric Reference Transducer is calibrated from 8 to 17 psia. Resolution: 6 digits. 11.3 Delta Channel The Delta Channel is a virtual channel that can display an arithmetic combination of the value of any two transducers that are installed. The Delta Channel is active when there is more than one transducer attached. When active, the Delta Channel can be chosen in the Frames App to be displayed in the Measure App and can be configured in the Transducer App as shown in figure 8.3. The Delta channel is enabled automatically when more than one transducer is connected. Figure 8.3 - Delta Channel Setup 11.4 External Transducers (CPT9000, CPR2510, CPT6100 and CPT6180) The CPT6100 and CPT6180 are stand alone Digital Pressure Transducers that can be purchased separately and connected to the remote transducer port on the back of the CPG2500. They can also be connected to an external sensor package (D-Sub) (See Section 8.5 below) that has been installed in the place of a removable transducer. The CPT6100 and CPT6180 have their own data sheets and manuals. 11.4.1 External Pressure Sensor Connection Cable A shielded ribbon cable is required to connect an external transducer and can be supplied with or without an external Transducer. The CPT6100/6180 part number is: 4060090001. The CPT9000 part number is 0020543003. 72 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 11.5 External Sensor Package (D-Sub) A plate with a D-Sub connector can be supplied with the instrument or after the initial purchase. This plate (See picture in section 5.4 Figure 5.4 B) can be installed in the place of a removable transducer to provide an additional connection for an external transducer (See section 8.4). When replacing a removable transducer with the plate, the internal ribbon cable that was connected to the removable transducer should be connected to the inside connector on the plate. 11.6 Analog Output The analog output option is available on all internal Transducers and on the CPT6100 external transducer. It can be configured at the time of manufacture to have voltage output that is directly proportional to the pressure input. 11.6.1 Specifications Resolution: 0-1 VDC 0-5 VDC 0-10 VDC 1 part per 80,000 minimum 1 part per 400,000 minimum 1 part per 800,000 minimum Update Rate: 150mS Uncertainties: 0-1 VDC 0-5 VDC 0-10 VDC 0.010% FS 0.010% FS 0.010% FS Minimum input impedance of the device measuring the analog output is 1 Megaohm. 11.7 Rack Mount Kit (CPX-A-G1-D of CPX-A-G1-R) The CPG2500 can be supplied with a single or dual 19” rack mount kit. Dual Rack Mount Single Rack Mount 11.8 Fittings (CPX-A-G1-M, CPX-A-G1-C, CPX-A-G1-B, CPX-A-G1-I, CPX-A-G1-E, CPX-A-G1-N, CPX-A-G1-A, CPX-A-G1-S, CPX-A-G1-F) A variety of fittings are available at the time of order on sensors with a max range of ≤ 15,015 psi (1,035 bar), or the CPG2500 can be ordered without adaptor fittings. Available fittings are shown in Section 9.2 - Spare Parts. An Autoclave F250C/ HIP HF4 is integral in all transducers with full scale ranges above 15,015 psi. 11.9 Remote Calibration (CPX-A-G1-4 or CPX-A-G1-5) A remote calibration sled, power supply, cable and software are available to calibrate the optional barometric reference. A cable / power supply and software are available to remotely calibrate the internal transducers outside of the CPG2500. In both cases a PC with a serial connection is required. Both kits are supplied with an instruction manual. Operating Instructions - CPG2500 73 Precision Pressure Indicator CPG2500 11.9.1 Remote Calibration Kit for Internal Transducers. The cable / power supply used to calibrate the internal transducers remotely can be ordered as an option (pn # 0017245002). Calibration of each internal transducer can be performed remotely using the cable, a PC, and software provided. Figure 8.9.1 - Remote Calibration Kit for Internal Transducer 11.9.2 Barometric Reference Calibration Sled The CPG2500 Calibration Sled Kit is available to provide a way to calibrate the barometric reference remotely. Calibration of the Barometric Reference can be performed remotely using the Cal sled, a PC and the software provided. Figure 8.9.2 - CPG2500 Barometric Reference Cal Sled Kit 74 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 11.9.3 External Calibration Procedures To calibrate the internal transducers or the barometric reference remotely, use the same setup described in section 10 of this manual. The only difference is that the interface with the transducer is through the software provided and a PC, not directly through the instrument. 11.9.3.1 Transducer Removal To remove the internal transducer, first remove the four slotted screws holding the transducer in the chassis, slide the transducer out of the back of the chassis and unplug the ribbon cable from the back of the transducer. Figure 8.9.3.1 - Transducer Removal 11.9.3.2 Barometric Reference Removal To remove the optional Barometric reference, first remove three screws holding the top panel of the chassis, then remove the top panel. This will reveal the barometer, Figure 8.9.3.2. The barometric reference can be removed by removing the attached hose, loosening the thumb screw, and lifting the barometric reference out of the chassis. ! CAUTION: ESD protection is required when performing this operation. Thumb Screw Figure 8.9.3.2 - Internal Barometric Reference Operating Instructions - CPG2500 75 Precision Pressure Indicator CPG2500 12 Maintenance The CPG2500 was designed for maintenance-free operation. User maintenance is not recommended, beyond replacement of parts listed in Table 9.2. If you have questions not covered by this manual, call 1.800.984.4200 (USA only), or 1.512.396.4200 for assistance, or send an e-mail to [email protected]. 12.1 Beyond the Warranty Take advantage of Mensor’s expert product care. Mensor provides complete maintenance and calibration services, available for a nominal fee. Our service staff is knowledgeable in the innermost details of all of our instruments. We maintain units that are in operation in many different industries and in a variety of applications, and by users with a wide range of requirements. Many of these instruments have been in service for over twenty years, and continue to produce excellent results. Returning your instrument to Mensor for service benefits you in several ways: • Our extensive knowledge of the instrument assures you that it will receive expert care. • In many cases we can economically upgrade an older instrument to the latest improvements. • Servicing our own instruments which are used in “real world” applications keeps us informed as to the most frequent services required. We use this knowledge in our continuing effort to design better and more robust instruments. 12.2 Spare Parts Table 9.2 lists the spare parts for the CPG2500 that can be ordered from Mensor. Table 9.2 - Spare Parts List Part Description Adaptor Fittings 6mm tube fittings (brass) 1/4” tube fittings (brass) 1/4” NPT female pipe thread (brass) 1/8” NPT female pipe thread (brass) 1/8 FBSPG female pipe thread (brass) 6mm tube fittings (Stainless) 1/4” tube fittings (Stainless) 1/4” NPT female pipe thread (Stainless) 1/8” NPT female pipe thread (Stainless) 1/8 FBSPG female pipe thread (Stainless) Kits/Manual Kit - Rack Mount adapter, single unit Kit - Rack Mount adapter, dual unit Manual 76 Part Number Pressure ≤ 3000 psi 3000 psi ≤ pressure ≤ 6015 psi 0018203043 0018203045 0018203005 0018203001 0018203018 0018203039 0018203027 0018203031 0018203035 0018203046 Part Number 00192610001 0019261002 0018908001 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 13 Calibration The CPG2500 automatically adjusts the pressure reading for the effects of temperature and non-linearity within the calibrated temperature range of 15-45°C. The process is referred to as dynamic compensation because each reading is so adjusted before it is output to the display or to a communication bus. Thus, a calibrated CPG2500 operated within its temperature band, and with proper zero and span adjustments, will provide accurate pressure measurements. The CPG2500 should have the calibration verified periodically to insure stability. The recommended calibration cycle is one year or six months depending on the transducer range. 13.1 Environment For maximum accuracy, allow the CPG2500 to warm up a minimum of 15 minutes in ambient temperature within the compensated range prior to a calibration. In addition, the instrument should be at rest on a stable platform that is free of excessive vibration and shock. 13.2 Pressure Standards Mensor recommends the use of appropriately accurate primary pressure standards when calibrating this instrument. Such standards should be sufficient so that when the techniques of the ISO Guide to the Expression of Uncertainty in Measurement (GUM) are applied, the instrument meets its accuracy statements as required by ISO/IEC 17025:2017, or other applicable standards. 13.3 Media The recommended calibration medium is dry nitrogen or clean dry instrument air. Hydraulic media can be used above 15 psi. A height variation between the standard and the CPG2500 can cause significant errors. A calculation should be made to compensate for this difference. Operating Instructions - CPG2500 77 Precision Pressure Indicator CPG2500 13.4 Setup The following illustration for calibration setup shows a typical setup for either local or remote calibration for an absolute or gauge pressure instrument. The equipment shown in the rectangle is only necessary for absolute calibration. The PC is required only for performing a remote calibration. The “Pressure Standard” is normally a deadweight test instrument, and the “Volume Controller” refers to a hand operated variable-volume pressure vernier device. A diaphragm type vacuum gauge is recommended over the gauge tube type of vacuum sensor for calibrating sub-atmospheric pressures. A vacuum pump with the capacity to generate 600 millitorr absolute is recommended. Unnecessary for Gauge Calibration Variable Leak Vacuum Shut Off Metering Valve Vacuum Pump Supply Volume Controller Vent PC for Remote Calibration Pressure Standard Vacuum Gauge Figure 10.4 - Calibration Setup When setting span while calibrating higher pressures (> 6,015 psia/401 bar) you must allow time (10 min. recommended) for temperature and pressure to stabilize. 78 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 13.5 Service Application The Service application is a password protected area where calibration of all connected sensors can be accomplished. In addition, this is where the password for entering this area can be changed. Figure 10.5-A - Service Application (locked) Press the Enter button to show the numeric keypad to enter a password. This will unlock other applications. The Default password is 123456. Enter 123456 and press the check mark [ ] to unlock the Service Application. Figure 10.5-B - Service Application (Enter Password) i Note: The default Password is 123456. After entering this for the first time, the password can be changed. Operating Instructions - CPG2500 79 Precision Pressure Indicator CPG2500 13.5.1 Service Application (unlocked) After the Password has been entered, the unlocked Service Application will appear (Figure 10.5.1). To re-lock this screen, press the Lock button. Figure 10.5.1 - Unlocked Service Application From the unlocked Service Application, the Password can be changed by pressing the Enter button next to the Change Password label. This will open a keypad where a new password can be entered and accepted by pressing the Check Mark [ ]. i ote: Please make note of a password change and save the new password in a secure N location. The Unlocked Service Application is the access point to all calibration screens described below. 80 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 13.6 Calibration Data The Calibration Data Application is where the calibration data for each transducer is stored and amended. The Serial number (S/N), Zero offset (Zero) and Span offset (Span) can be seen in this screen. The date of calibration, the calibration interval and the certificate number can be entered by pressing the corresponding button, then saved by pressing the Check [ ] button. To revert back to the factory calibration, press the “Restore Factory Cal” button. To view the calibration data for each transducer press the “Channel” button at the top and choose a transducer from the resulting channel selection menu. Figure 10.6 - Calibration Data 13.7 One Point Cal Application A single point calibration (usually a zero point calibration) of each transducer installed can be accomplished in “One Point Cal” Application. The transducer channel is chosen by pressing the “Channel” button at the top of this screen, and then selecting from the list of installed transducer channels. For gauge pressure simply expose the reference and the pressure port of the transducer to atmospheric pressure and then press the “New Value” button and enter zero (0) using the keypad. For an absolute transducer apply a known reference pressure between 600 mTorr absolute and 20% of the selected transducer’s span to the pressure port of the transducer, press the “New Value” button and then enter the reference pressure (known true pressure) using the keypad. After a valid reference value is entered, the Save button will become active. If you want to save the value in the sensor, press Save to permanently save the adjustment to the transducer. Notice the reference symbol [ ], this is a reference indication giving a constant reference point for the level of the internal sensor. Figure 10.7 - One Point Cal Application Operating Instructions - CPG2500 81 Precision Pressure Indicator CPG2500 13.8 Two Point Cal Application The Two Point Cal Application provides a place to adjust the Transducer Zero and Span (sometimes referred to as the offset and slope). Figure 10.8 - Two Point Cal Application Follow the steps below for a complete 2 Point Calibration: Select a Transducer to calibrate by pressing the Channel button at the top of the screen. To calibrate the “low Point”: 1. The pressure port of the transducer being calibrated should be supplied with a suitable, “low point” pressure (see section 5.4 Rear Panel for the port location). 2. For a gauge transducer, this low point pressure can be achieved by opening the pressure and reference ports to atmospheric pressure. 3. For an absolute transducer a suitable source of vacuum should be applied to the Pressure port along with a high accuracy vacuum standard or a pressure calibration standard can be connected to the Pressure port that can generate and measure a stable pressure value between 600 mTorr absolute and 20% of the active transducer’s span 4. When the pressure is stable, record the live reading shown on the Two Point Cal screen and enter this value as the “Low Reading” by pressing the Low Reading button and entering the number followed by the check mark [ ]. Record the “true pressure” obtained from the reference standard and enter it as the “Low Reference” value in the same manner. To calibrate the”High Point”: 5. The “High Point” Calibration is done in a similar way as the “Low Point”. 6. Supply a pressure to the Pressure Port of the Transducer being calibrated, using a pressure standard. This pressure should be as close as possible to the full scale value of the selected transducer or at least within 20% of that value. 7. After the pressure stabilizes, record live reading shown on the Two Point Cal screen and enter this value as the “High Reading” by pressing the High Reading button and entering the number followed by the check mark [ ]. Record the “true pressure” obtained from the reference standard and enter it as the “High Reference” value in the same manner. 82 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 When the “High Reading” or “Low Reading” is selected, the main reading will become a button. When pressed the current reading will be used as a value. Figure 10.8-B “High Reading” and “Low Reading” After all four values (High Reference, High Reading, Low reference, & Low reading) have been entered, the Adjust button will become active. Press the Adjust button to check and accept the calibration data then press the Save button. The instrument will then prompt with the question “Save Cal Data?”. Pressing the check mark [ ] in this screen will save the calibration to the memory of the sensor. 13.9 Linearization The Linearization Application provides a place to record upscale and downscale calibration data and to linearize each transducer using that data. An “as found calibration” can be performed by connecting a suitable pressure standard to the Measure port of the CPG2500 channel being calibrated, and supplying between 3 and 11 pressure points across the complete range. The pressure points may be entered using both upscale and downscale pressure points, or only one direction (Figure 10.9-A). The “clear existing linearity” button erases the current linearization on the selected transducer. Pressing the “Start” button presents the next screen. The record of the pressures from the pressure standard and the corresponding reading from the instrument’s transducer can be recorded and transcribed into this screen called the Linearization Matrix shown in Figure 10.9-B. Linearization of each transducer can be performed from this screen by selecting each transducer range from the setup screen. Operating Instructions - CPG2500 83 Precision Pressure Indicator CPG2500 Figure 10.9-A - Linearization Application Setup The Linearization Application automatically populates the screen with 10% increments from the low to high pressure corresponding to the range of the transducer selected. These values can be changed to reflect the values generated by the standard and the corresponding readings taken from the CPG2500. Each value from the standard can be entered under the reference column, corresponding Upscale and Downscale readings from the instrument can be entered in the “Upscale” and “Downscale” columns. To enter a value simply press the number and a key pad will appear (see Figure 10.9-B) where the number can be entered. Press the check mark [ ] to accept each value. The “Average” column automatically averages the upscale and downscale values. Figure 10.9-B - Linearization Values Figure 10.9-B shows some typical values that might be seen in a linearization calibration. In the bottom right hand corner of this screen is the Graph Icon [ ] that, when pressed, reveals a Linearization Error Graph (figure 10.9-C) that gives a visual representation of the errors associated with the values entered in the Linearization screen. When one of the actual pressure readings in selected, the main reading will become a button. When pressed, the current reading will be used as the value. 84 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 Figure 10.9-C Value Selected This Linearization error graph shows a scaling that corresponds to the maximum error calculated from the data entered in the Linearization Matrix. It is a good indication of the overall error of the transducer, and will quickly reveal any gross data entry errors that have been made. To revert back to the Linearization Matrix press the Matrix Icon [ ]. Relative Scale Figure 10.9-C - Linearization Error Graph When satisfied that all values have been entered correctly, press the adjust button and then the save button to save the new calibration data in the transducer memory. i Note: After calibration is complete, return to the Calibration Data Application (Section 10.6) to record the certificate number, calibration interval and the date of calibration. Restoration to factory calibration can also be completed in this application. Operating Instructions - CPG2500 85 Precision Pressure Indicator CPG2500 13.10 Head Pressure The Head Pressure Application provides an automated way to calculate the head pressure offset between a device being tested and the CPG2500 sensor, based on: • Local Gravity • Media: pneumatic or hydraulic • eight: the difference between the device under test and the sensing element in the transducers (inH ternal and external) in the CPG2500. Height difference = CPG2500-DUT As an example, if the device under test (DUT) is 10 inches above the CPG2500, enter - 10 inches in the “Height” button. • Media Density: the media density of the pressure media. Choices for pnuematic media are Nitrogen or Dry Air. For Hydraulic media a value may be entered. • Media Temperature: Only applicable with pneumatic media. The Head Pressure application is placed under the password protected area of the operator interface to safeguard against inadvertent activation. It is intended to be used to accurately measure the pressure at an external source that is at a different elevation from the CPG2500 transducer sensing that pressure. The four parameters are used to calculate the pressure that is a result of the different elevations. It should not be used when calibrating CPG2500 transducers. The Head height should be set at zero before calibrating the transducers of the CPG2500. i Notice The Head Pressure should not be active when calibrating CPG2500 transducers. The Head height should be set at zero before calibrating the transducers of the CPG2500. Difference in height between the laboratory standard and the CPG2500 during calibration should be factored into the uncertainty analysis. Figure 10.10-A shows the Head Pressure pneumatic screen. The height, media density (Nitrogen or dry air), media temperature and local gravity can be entered here based on the specific setup of the system. Figure 10.10-A - Head Pressure, Pneumatic Operating Instructions - CPG2500 86 Precision Pressure Indicator CPG2500 The head pressure may be set individually for each channel. With the channel set to “All”, every channel installed in the CPG2500 will use the same head pressure correction values. Figure 10.10-B Head Pressure Channel Figure 10.10-C Pressure values (Channel A) Figure 10.10-D shows the Head Pressure hydraulic screen. The height, media density, media temperature and local gravity can be entered here based on the specific setup of the system Figure 10.10-D - Head Pressure, Hydraulic 87 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 14 Appendix Table 11.1 - Measurement Units (unitno) Code Description Output Format 2 inches of mercury @ 0°C inHg 0°C 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 n/a n/a pounds per square inch inches of mercury @ 60°F inches of water @ 4°C inches of water @ 20°C inches of water @ 60°F feet of water @ 4°C feet of water @ 20°C feet of water @ 60°F millitorr inches of seawater @ 0°C 3.5% salinity feet of seawater @ 0°C 3.5% salinity atmospheres bars millibars millimeters of water @ 4°C centimeters of water @ 4°C meters of water @ 4°C millimeters of mercury @ 0°C centimeters of mercury @ 0°C torr kilopascals pascals dyne per square centimeter grams per square centimeter kilograms per square centimeter meters of seawater @ 0°C 3.5% salinity ounce per square inch pounds per square foot tons per square foot percent of full scale micron HG @ 0°C ton per square inch n/a hectopascals megapascals millimeters of water @ 20°C centimeter of water @ 20°C meters of water @ 20°C User Units 1 User Units 2 Operating Instructions - CPG2500 PSI inHg 60°F inH2O 4°C inH2O 20°C inH2O 60°F ftH2O 4°C ftH2O 20°C ftH2O 60°F mTorr inSW ftSW ATM Bar mBar mmH2O 4°C cmH2O 4°C MH2O 4°C mmHg 0°C cmHg 0°C Torr kPa PA Dy/cm2 gm/cm2 kg/cm2 MSW OSI PSF TSF %FS µHg 0°C TSI n/a hPa MPa mmH2O 20°C cmH2O 20°C MH2O 20°C User defined User defined 88 Precision Pressure Indicator CPG2500 14.1 Conversion Factors, PSI The values listed in the column “To convert from PSI” are the values imbedded in the instrument program. The values listed under “To convert to PSI” are internally calculated approximations based on the imbedded values. Table 11.2 - Conversion Factors, PSI Code Pressure Unit To convert from PSI To convert to PSI 2 inHg 0°C 2.036020 0.4911544 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 35 36 37 38 39 89 PSI inHg 60°F inH2O 4°C inH2O 20°C inH2O 60°F ftH2O 4°C ftH2O 20°C ftH2O 60°F mTorr inSW 0°C 3.5% salinity ftSW 0°C 3.5% salinity ATM Bar mBar mmH2O 4°C cmH2O 4°C MH2O 4°C mmHg 0°C cmHg 0°C Torr kPa PA Dy/cm2 gm/cm2 kg/cm2 MSW 0°C 3.5% salinity OSI PSF TSF %FS µHg 0°C TSI hPa MPa mmH2O 20°C cmH2O 20°C MH2O 20°C 1 2.041772 27.68067 27.72977 27.70759 2.306726 2.310814 2.308966 51715.08 26.92334 2.243611 0.06804596 0.06894757 68.94757 703.0890 70.30890 0.7030890 51.71508 5.171508 51.71508 6.894757 6894.757 68947.57 70.30697 0.07030697 0.6838528 16 144 0.072 (PSI / RANGE) x 100 51715.08 0.0005 68.94757 0.006894757 704.336 70.4336 0.704336 1 0.4897707 0.03612629 0.03606233 0.03609119 0.4335149 0.4327480 0.4330943 0.00001933672 0.03714250 0.445710 14.69595 14.50377 0.01450377 0.001422295 0.01422295 1.422295 0.01933672 0.1933672 0.01933672 0.1450377 0.0001450377 0.00001450377 0.01422334 14.22334 1.462303 0.0625 0.006944444 13.88889 (% FS x RANGE) / 100 0.00001933672 2000 0.01450377 145.0377 0.001419777 0.01419777 1.419777 Operating Instructions - CPG2500 Precision Pressure Indicator CPG2500 14.2 Conversion Factors, Millitorr The following table lists factors which should be used as multipliers when converting other pressure units to or from millitorr. Table 11.3 - Conversion Factors, millitorr Code Pressure Unit To convert from millitorr To convert to millitorr 2 inHg 0°C 0.00003936995 25400.08909 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 32 33 35 36 37 38 39 PSI inHg 60°F inH2O 4°C inH2O 20°C inH2O 60°F ftH2O 4°C ftH2O 20°C ftH2O 60°F mTorr inSW 0°C 3.5% salinity ftSW 0°C 3.5% salinity ATM Bar mBar mmH2O 4°C cmH2O 4°C MH2O 4°C mmHg 0°C cmHg 0°C Torr kPa PA Dy/cm2 gm/cm2 kg/cm2 MSW 0°C 3.5% salinity OSI PSF TSF µHg 0°C TSI hPa MPa mmH2O 20°C cmH2O 20°C MH2O 20°C Operating Instructions - CPG2500 0.00001933672 0.00003948117 0.0005352534 0.0005362028 0.0005357739 0.00004460451 0.00004468356 0.00004464783 1.0 0.0005206091 0.00004338408 0.000001315786 0.000001333220 0.001333220 0.0135954 0.001359544 0.00001359544 0.001 0.0001 0.001 0.0001333220 0.1333220 1.333220 0.001359506 0.000001359506 0.00001322347 0.0003093875 0.002784488 0.000001392244 1.0 0.00000000966836 0.001333220 0.0000001333220 0.01361955 0.001361955 0.00001361955 51715.08 25328.53093 1868.273977 1864.966281 1866.458778 22419.25773 22379.59744 22397.50637 1.000000000 1920.827359 23049.92831 760002.2299 750063.6259 750.0636259 73.5540997 735.5409971 73554.09971 1000.000000 10000.00000 1000.000000 7500.636259 7.500636259 0.750063626 735.561166 735561.166 75623.11663 3232.1992 359.132477 718265.0575 1.000000000 103430160.00 750.0636259 7500636.259 73.42388114 734.2388114 73423.88114 90 Precision Pressure Indicator CPG2500 14.3 Conversion Factors, Pascal The following table lists factors which should be used as multipliers when converting other pressure units to or from Pascal. 11.4 - Conversion Factors, Pascal Unit No. Pressure Unit To convert from Pascal To convert to Pascal 2 inHg 0°C 2.952997E-04 3.386390E+03 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 32 33 35 36 37 38 39 PSI inHg 60°F inH2O 4°C inH2O 20°C inH2O 60°F ftH2O 4°C ftH2O 20°C ftH2O 60°F mTorr inSW 0°C 3.5% sal ftSW 0°C 3.5% sal ATM Bar mBar mmH2O 4°C cmH2O 4°C MH2O 4°C mmHg 0°C cmHg 0°C Torr kPa PA Dy/cm2 gm/cm2 kg/cm2 MSW 0°C 3.5% sal OSI PSF TSF µHg 0°C TSI hPa MPa mmH2O 20°C cmH2O 20°C MH2O 20°C Operating Instructions - CPG2500 1.450377E-04 2.961339E-04 4.014741E-03 6.894757E+03 3.376850E+03 2.490820E+02 4.021862E-03 2.486410E+02 3.345622E-04 2.988980E+03 4.018645E-03 2.488400E+02 3.351551E-04 2.983692E+03 7.500636E+00 1.333220E-01 3.348871E-04 3.904899E-03 3.254082E-04 9.869230E-06 1.00000E-05 1.00000E-02 1.019744E-01 1.019744E-02 1.019744E-04 7.500636E-03 7.500636E-04 7.500636E-03 1.00000E-03 1.00000E+00 1.00000E+01 1.019716E-02 1.019716E-05 9.918444E-05 2.320603E-03 2.088543E-02 1.044271E-05 7.500636E+00 7.251885E-08 1.00000E-02 1.00000E-06 1.021553E-01 1.021553E-02 1.021553E-04 2.986080E+03 2.560885E+02 3.073062E+03 1.013250E+05 1.00000E+05 1.00000E+02 9.806378E+00 9.806378E+01 9.806378E+03 1.333220E+02 1.333220E+03 1.333220E+02 1.00000E+03 1.00000E+00 1.00000E-01 9.806647E+01 9.806647E+04 1.008222E+04 4.309223E+02 4.788025E+01 9.576052E+04 1.333220E-01 1.378951E+07 1.00000E+02 1.00000E+06 9.789017E+00 9.789017E+01 9.789017E+03 91 Mensor 201 Barnes Drive San Marcos, Texas 78666 Tel: 512-396-4200 Website: www.mensor.com Fax: 512-396-1820 Email: [email protected] Precision Pressure Indicator CPG2500 PN 0018908001P • 09/2019 WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 D-63911 Klingenberg / Germany Tel: (+49) 93 72/132-5015 Website: www.wika.de Fax: (+49) 93 72/132-8767 Email: [email protected] ">

Public link updated
The public link to your chat has been updated.
Advertisement