Land Pride 3P1006NT Accessory Manual

Land Pride 3P1006NT Accessory Manual
Great Plains Mfg., Inc.
Installation Instructions
1
Electronic Acremeter
Great Plains Drills and Seeders
Used with most Great Plains Drillsa (this includes all fertilizer and heavy duty models of drills listed)
• 2S-2600, 3S-3000, 3S-4000, 3S-5000
• 2N-2410, 2N-3010, 2N-2420, 2N-3020
• 605NT, 606NT, 706NT, 1006NT, 1205NT, 1206NT
• 3P605NT, 3P606NT, 3P806NT, 3P1006NT
• 3P500, 3P500V, 3P600
• 3P1200, 1210, 1220, 1500, 1510, 1520, 2000, 2010, 2020 (fluted feed drills only)
• 3P2400 (fluted feed drills only)
• 800, 1300
• NTS2507, NTS2509, NTS2511 (Seeders)
General Information
These instructions include both operation and installation
of an Electronic Acremeter.
Installation
•
•
•
•
If installation is necessary, order the appropriate kit
(see “Acremeter Kits”, page 33 through page 39).
Consult your Great Plains dealer for specific ordering
information.
Each acremeter upgrades one drill.
Installation instructions start at “Acremeter Installation” on page 13.
Kit
Product Description
118-260A
3P LOUP ACREMETER
152-326A
NO-TILL LOUP ACREMETER
152-327A
3P LOUP ACREMETER
152-328A
NO-TILL DUAL SEED/NG ACREMETER
152-329A
3P DUAL SEED/NG ACREMETER
175-311A
EW LOUP ACREMETER
194-073A
MIN-TILL ELECTRONIC ACRE METER
197-187A
2SNT LOUP ACREMETER
152-344L
1206NT NG ACREMETER
152-337A
1206NT LOUP ACREMETER
152-351A
1205NT LOUP ACREMETER
313-854A
NTS25 DIGITAL ACREMETER
Figure 1
Electronic Acremeter
Programming the Acremeter
Reference Information
•
•
•
•
If your drill was equipped with this acremeter from
production, it will have been supplied already
programmed.
You will need to program your new acremeter if it is
not preprogrammed to your drill or if you ordered it
and install it yourself. See “Acremeter Operations”
on page 2 of this manual.
34776
Find “Calibration For All Drill Models”on page 4.
Find “Drill Width Charts” on pages 7 and 8.
Tools Required
•
basic hand tools.
a. The electronic acremeter is compatible with all drills having a main or transfer 7/8 hex drive shaft on any section of the drill. The shaft must
be before any Drive Type, gearbox, lower, range, transmission or upper variable sprockets, and have only fixed sprockets and chains
between the drive wheel and the shaft.
©Copyright 2016
Printed 2017/09/19
194-074M
Great Plains Mfg., Inc.
2
Electronic Acremeter
Acremeter Operations
A battery-operated electronic acre counter is supplied
with the drill. The display module for the system is
normally on the front face of the main toolbar near the left
gauge wheel.
The acremeter calculates and displays the field acres
and total acres accumulated.
The meter counts rotations of the main ground drive shaft
before the clutch. The meter tallies all movements with
the drill unfolded, whether planting or not.
1
The counter operates in one of two modes
• In sleep mode, the display 1 is blank, and the counter
is accumulating acres. Sleep mode is entered if a
button is not pressed for 20 seconds. If a passcode is
set, it must be re-entered to change protected function
values.
• In entry mode, the display is on, and the operator can
enter values. To access entry mode, press the
button 2 . If you continue to press the
button, the
acre counter cycles through the available functions.
The LED light above the functions indicates which
function is selected.
The functions are:
FIELD
TOTAL
PULSES
WIDTH
P-WORD
Field Acres
Total Acres
Pulses per Mile
Swath Width
Password
2
4
Figure 2
Acremeter Console
3
34776
(always unprotected)
(passcode protectable)
(passcode protectable)
(passcode protectable)
(enable/set/change/clear)
Note: U = USA units or acres
E = European units or hectares
Values are entered by pressing the UP 3 and
DOWN 4 arrow buttons. Holding a button
automatically increments that value. Long holds
increment faster than short holds. Pressing both
buttons simultaneously is used to reset some values
to 0.
•
To change modes press and hold all 3 switches at the
same time. When pressed, the current mode will
scroll across the screen. “U” is for USA units, “E” is for
European (metric) units. When you have held all
3 switches for 5 seconds the mode will change.
This means you can check the mode at any time by
pressing the 3 keys and releasing them before
5 seconds has passed without changing anything.
Note: When you change modes, all the defaults are
reset to factory values so these will need to be set
properly for the machine. Also area accumulated
in one mode is not converted. It is reset to 0.
194-074M
2017/09/19
Great Plains Mfg., Inc.
Installation Instructions
3
Field Acres
Refer to Figure 3
Press the
button until the “FIELD” LED is lit. The digits
indicate the acres covered since the field acre counter
was last cleared to zero.
To clear the field acre count, depress the UP and DOWN
buttons for 2 seconds.
Note: If a passcode is set, it must be entered to clear the
total acre count.
Field acres count in tenths of an acre up to 9999.9 acres.
Figure 3
Field Acres Display
34813
Figure 4
Total Acres Display
34775
Total Acres
Refer to Figure 4
Press the
button until both the “FIELD” and “TOTAL”
LEDs are lit. The digits indicate the acres covered since
the total acre counter was last cleared to zero.
To clear the total acre count, press and hold the UP and
DOWN buttons for 2 seconds.
Note: If a passcode is set, it must be entered to clear the
total acre count.
Total acres count from .1 to 99999 acres.
2017/09/19
194-074M
Great Plains Mfg., Inc.
4
Electronic Acremeter
Pulses per 400 Feet of Travel
Press the
button until the “PULSES” LED is lit. The
number in the display indicates how many pulses are
generated for every 400 feet (122 meters in “E” mode)
driven.
Note: If a passcode is set, it must be entered to adjust
the pulses per 400 feet (122 meters) of travel.
There are two methods to enter the pulses: known pulse
value and calibrating pulses per 400 feet (122 meters) of
travel.
Known Pulses Values
Refer to Figure 5
1. If you know the number, select it using the UP and
DOWN buttons. When you press the
button, the
controller accepts the number in the display as the
new pulses per 400 feet (122 meters).
EXAMPLE:
Approximate pulses per 400 feet (122 meters) for
2S-2600, 3S-3000, 3S-4000 and 3S-5000: 17.
Figure 5
Example: Pulses Per 400 Feet Entry
for 2S-2600/3000/4000/5000
Calibration For All Drill Models
Model
Calibration
2S-2600, 3S-3000, 3S-4000, 3S-5000
2N-2410, 2N-3010, 2N-2420, 2N-3020
706NT, 1006NT
1205NT, 1206NT
606NT
3P606NT, 3P806NT, 3P1006NT
3P500, 3P500V, 3P600
800EWD
1300EWD
3PT 1200, 1500
3PT 2000, 2400
NTS2507, NTS2509, & NTS2511
17
31
36
38
52
46
46
52
16
51
49
94
194-074M
34778
2017/09/19
Great Plains Mfg., Inc.
Installation Instructions
5
Calibrating Pulses per 400 Feet of Travel
Note: Calibration is not recommended for the 2S-2600,
3S-3000, 3S-4000, or 3S-5000. Any value other
than 17 pulses per 400 feet results in reduced
accuracy of area measurement.
Refer to Figure 6
The acremeter can count pulses, and if the distance
driven is known, the pulses per 400 feet of travelb may be
entered. Run the test with the drill unfolded, and the
openers raised.
Pulses Per Mile
Note: If you have documentation yet from a past design
of acremeter listing the pulse value stated as
pulses per mile, divide that value by 13.2 to arrive
at a new number. (5280 feet per mile/400 ft =
13.2). If you get a fraction round up to the next full
digit for the best accuracy.
PulsesCounted PerMile
Pulses Per 400 ft of Travel = --------------------------------------------------------13.2
Pulses Per 400 Feet
To calibrate the pulses per 400 feet of travel, press and
hold the UP and DOWN buttons until “0” appears in the
PULSES display. The acre counter is now ready to count
shaft rotations.
Figure 6
Count Pulses Per 400 feet of Travel
34778
Enter the tractor cab and drive 400 feet.
Press the
button to wake up the acre counter. The
“PULSES” LED will again blink. The number displayed is
the pulses per 400 feet. Press the
button to accept the
setting. The “PULSES” LED will stop blinking and remain
on.
b. For more accurate calibration, operate for some multiple of 400 feet (say 1600 ft) divide the count by that multiple and round off.
2017/09/19
194-074M
Great Plains Mfg., Inc.
6
Electronic Acremeter
Width
To correctly calculate acres planted, the acremeter needs
the swath width of the drill.
Note: If a passcode has been set, it must be entered to
adjust WIDTH.
Refer to Figure 7
Press the
button until the “WIDTH” LED is lit. The
number displayed is the swath width of your implement in
feet (the span between end row units, plus one row unit
spacing).
To adjust the width, press the UP and DOWN buttons.
The width can be adjusted from .1 to 99.9 feet, in tenths
of a foot.
Model
Spacing
2S-2600/F/HD/HDF-3210
10 in.
2S-2600/F/HD/HDF-4275
7.5 in.
2S-2600/F/HD/HDF-5206
6 in.
Model
Spacing
3S-3000/F/HD/HDF-3610
10 in.
3S-3000/F/HD/HDF-4875
7.5 in.
3S-3000/F/HD/HDF-6006
6 in.
Model
Spacing
3S-4000/F/HD/HDF-4810
10 in.
3S-4000/F/HD/HDF-6375
7.5 in.
3S-4000/F/HD/HDF-7806
6 in.
Model
Spacing
3S-5000/F/HD/HDF-6010
10 in.
3S-5000/F/HD/HDF-8075
7.5 in.
3S-5000/F/HD/HDF-1006
6 in.
194-074M
Width
26.7 feet
8.1 meters
26.3 feet
8.0 meters
26.0 feet
7.9 meters
Width
30.0 feet
9.1 meters
30.0 feet
9.1 meters
30.0 feet
9.1 meters
Figure 7
Drill Width (Swath)
34779
Note: Implement width in “U” mode is USA feet to one
decimal place.
Implement width in “E” mode is in meters to one
decimal place.
Width
40.0 feet
12.2 meters
39.4 feet
12.0 meters
39.0 feet
11.9 meters
Width
50.0 feet
15.2 meters
50.0 feet
15.2 meters
50.0 feet
15.2 meters
2017/09/19
Great Plains Mfg., Inc.
Installation Instructions
7
Drill Width Charts
2017/09/19
Model
Spacing
Width
2N-2410-2810
2N-2410-3875
2N-3010-3610
2N-3010-4875
10 in.
7.5 in.
10 in.
7.5 in.
23.3 feet (7.1 meters)
23.8 feet (7.9 meters)
30.0 feet (9.1 meters)
30.0 feet (9.1 meters)
Model
Spacing
Width
2N-2420-2810
2N-2420-3875
2N-3020-3610
2N-3020-4875
10 in.
7.5 in.
10 in.
7.5 in.
23.3 feet (7.1 meters)
23.8 feet (7.9 meters)
30.0 feet (9.1 meters)
30.0 feet (9.1 meters)
Model
Spacing
Width
606NT-0975
706NT-1075
1006NT-1575
1205NT-1975
3P606NT-0975
3P806NT-1375
3P1006NT-1575
1206NT-1410
1206NT-1808
1206NT-1975
1206NT-2007
7.5 in.
7.5 in.
7.5 in.
7.5 in.
7.5 in.
7.5 in.
7.5 in.
10 in.
8 in.
7.5 in.
7 in.
5.6 feet (1.7 meters)
6.3 feet (1.9 meters)
9.4 feet (2.9 meters)
11.9 feet (3.6 meters)
5.6 feet (1.7 meters)
8.1 feet (2.5 meters)
9.4 feet (2.9 meters)
11.6 feet (3.5 meters)
12 feet (3.6 meters)
11.8 feet (3.6 meters)
11.6 feet (3.5 meters)
Model
Spacing
Width
3P600-0975
3P600-1106
3P500-0775
3P500-0906
3P500-0775 (V)
3P500-0872 (V)
3P500-0906 (V)
7.5 in.
6 in.
7.5 in.
6 in.
7.5 in.
7.25 in.
6 in.
5.6 feet (1.7 meters)
5.5 feet (1.7 meters)
4.4 feet (1.3 meters)
4.5 feet (1.4 meters)
4.4 feet (1.3 meters)
4.8 feet (1.5 meters)
4.5 feet (1.4 meters)
Model
Spacing
Width
800-1275
800-1506
1300-1610
1300-2175
1300-2506
7.5 in.
6 in.
10 in.
7.5 in.
6 in.
8.1 feet (2.5 meters)
7.5 feet (2.3 meters)
13.3 feet (4.1 meters)
13.1 feet (4.0 meters)
13.0 feet (4.0 meters)
194-074M
Great Plains Mfg., Inc.
8
Electronic Acremeter
Drill Width Charts (continued)
194-074M
Model 1200/1210/1220
Spacing
Width
1200-1410 (3PT)
1200-1808 (3PT)
1200-1975 (3PT)
1200-2007 (3PT)
1200-2406 (3PT)
10 in.
8 in.
7.5 in.
7 in.
6 in.
11.7 feet (3.6 meters)
12.0 feet (3.6 meters)
11.9 feet (3.6 meters)
11.7 feet (3.6 meters)
12.0 feet (3.6 meters)
Model 1500/1510/1520
Spacing
Width
1500-1810 (3PT)
1500-2208 (3PT)
1500-2475 (3PT)
1500-2607 (3PT)
1500-3006 (3PT)
10 in.
8 in.
7.5 in.
7 in.
6 in.
15.0 feet (4.6 meters)
14.7 feet (4.5 meters)
15.0 feet (4.6 meters)
15.2 feet (4.6 meters)
15.0 feet (4.6 meters)
Model 2000/2010/2020
Spacing
Width
2000-2410 (3PT)
2000-3008 (3PT)
2000-3275 (3PT)
2000-3407 (3PT)
2000-4006 (3PT)
10 in.
8 in.
7.5 in.
7 in.
6 in.
20.0 feet (6.1 meters)
20.0 feet (6.1 meters)
20.0 feet (6.1 meters)
19.8 feet (6.0 meters)
20.0 feet (6.1 meters)
Model
Spacing
Width
2400-2810 (3PT)
2400-3608 (3PT)
2400-3875 (3PT)
2400-4007 (3PT)
2400-4806 (3PT)
10 in.
8 in.
7.5 in.
7 in.
6 in.
23.3 feet (7.1 meters)
24.0 feet (7.3 meters)
23.8 feet (7.3 meters)
23.3 feet (7.1 meters)
24.0 feet (7.3 meters)
Model
Spacing
Width
NTS2507
NTS2509
NTS2511
7.2 in.
7.2 in.
7.2 in.
7.3 feet (2.2 meters)
8.5 feet (2.6 meters)
10.9 feet (3.3 meters)
2017/09/19
Great Plains Mfg., Inc.
Installation Instructions
9
Passcode
The “P-WORD” function allows you to protect:
- the total acre count,
- pulses per 400 feet and
- width
settings with a 4-digit passcode. This prevents accidental
and malicious changes to those settings. As provided by
the factory, the passcode feature is disabled, and you
can modify those function values at any time.
Press the
button until the “P-WORD” LED is lit. The
display reads either:
“Ent” (enter passcode) or
“dIS” (passcode disabled)
Enable and Set Passcode
The P-WORD display must show “dIS” in order to enable
and set a passcode on a unit which presently has no
passcode (see below for changing an existing
passcode).
Refer to Figure 8
Use the UP and DOWN buttons to select a passcode in
the range 0001 through 9999 (0000 disables).
Figure 8
Password Presently Disabled
34777
Figure 9
Password Prompt “ENT”
34780
Press
button to accept the passcode. If the module
enters sleep mode before you press the
button, the
passcode is not set.
Note: The protected function values remain unprotected
until the next time the module enters sleep mode.
Using a Passcode
If the P-WORD display shows “Ent”, a passcode must be
entered, or the protected function values cannot be
changed.
Refer to Figure 9
Enter the passcode using the UP and DOWN buttons.
When your passcode is displayed, press the
button to
test the passcode.
If the passcode is correct, you can change the protected
settings.
The protected settings are unprotected, and the
password remains viewable in the P-WORD display
function, until the module next enters sleep mode. When
button is next pressed, the passcode is again required
to change protected settings.
If the entered passcode is not correct, the protected
settings cannot be changed. When the “P-WORD”
function is selected again, “Ent” appears in the display.
2017/09/19
194-074M
Great Plains Mfg., Inc.
10
Electronic Acremeter
Changing the Passcode
To change an existing passcode, first enter the existing
password as described in ““Using a Passcode””.
Refer to Figure 10
While still in the P-WORD function display, select a new
passcode using the UP and DOWN buttons.
Press and hold the
button until the “SEt” (setting
password) appears in the display. Release the
button.
The number in the display is your new password. Be sure
to record it.
To disable the passcode, set the new password to 0000
(press and hold both UP and DOWN to do this quickly).
Press and hold the
button until “dIS” (passcode
disabled) appears in the display.
If the passcode is forgotten, it can be disabled by
removing the batteries. In rental or managed commercial
operations, it is recommended that a tamper-evident seal
be affixed to the rear plate of the acre counter (securing
the battery compartment).
Figure 10
Password Change Prompt
194-074M
34810
2017/09/19
Great Plains Mfg., Inc.
Installation Instructions
11
Battery Replacement
The battery operated acre counter uses 3 AA-size
alkaline batteries. Although the batteries typically last
between 5 and 10 years, they should be inspected
annually, as low batteries can leak corrosive chemicals,
and damage the electronic acremeter.
If battery replacement is needed, the acre counter
displays “LobAt” (low battery).
For battery inspection or replacement, dismount the acre
counter from the implement and remove the 4 screws on
the back of the case. This will separate the housing from
the rear plate. Replace the batteries with 3 high quality
AA alkaline batteries.
Note: The module is dust and splash resistant, but under
no circumstance should it be submerged in any
conductive, corrosive or flammable liquid.
2017/09/19
Figure 11
Replacing Batteries
34812
Figure 12
Replacing Batteries
34761
194-074M
Great Plains Mfg., Inc.
12
Electronic Acremeter
Reference Information
Accuracy Considerations
Many factors can affect the accuracy of your electronic
acremeter:
•
•
Tire Size and Tire Pressure
Seeding Overlap
The area reported by the meter will be higher than the
actual field area if passes overlap.
•
Soil Conditions
The meter configuration was programmed for nominal
tire slippage. Extreme conditions, wet or muddy
conditions, min-till/no-till conditions and some native
grass conditions may change wheel slippage,
resulting in slightly inaccurate area tallies.
Display
Liquid Crystal Displays (LCDs) do not function optimally
in extremely cold conditions (conditions colder than you
are likely to be planting in). If the display is blank, hard to
read, or sluggish, and the weather is near freezing, the
LCD is likely responding to the temperature.
The battery, rotational sensor and computer electronics
are still operating, however, and read-out will be possible
once the meter warms up. Do not use direct application
of hot air, fluids or metal to warm up the meter, or you
may damage it.
194-074M
2017/09/19
Great Plains Mfg., Inc.
Installation Instructions
13
Acremeter Installation
NTS25 Series Seeders
Note: Refer to your NTS Seeder Operator’s Manual for
installation instructions and Parts Manual for
replacement part numbers. For all other machines,
continue with instructions below.
Prepare Drill
Note: The following examples and instructions are for
the 2S-2600. Use the instructions as a guide while
referring to the illustration for your specific drill’s
acremeter placement starting at “Acremeter
Diagrams” on page 16 through page 29.
The following installation instructions for installing
the sensor, actuator and meter also use the
2S-2600 for the example and assembly steps. Use
these instructions as a guide making sure to
consult the kit contents for your particular drill
starting at “Acremeter Kits” on page 33 through
page 37.
Refer to Figure 13
1. The work may be performed with the drill raised or
lowered. If lowered, a wrench may not be needed, as
the drive shaft cannot rotate.
2
1
Figure 13
Shaft and Meter
(3S-3000/4000/5000)
34817
Identify the Mounting Location
2. SENSOR: If the drill does not presently have a
shaft-mounted acremeter, look for a 78 inch
hexagonal drive shaft 1 with the drive clutch
connected (this is usually the main jack shaft).
Mount the sensor on the two-hole bearing flangette
at one end of this shaft.
3. METER: Mount the acremeter console on the front
face of the main frame toolbar 2 in a location close
to the sensor.
Note: For 2S-2600 model: Mount meter on the right
hand box frame.
For 3S-3000/4000/5000 models: Mount meter on
the center box frame and the meter will remote
mount on the left hand box frame.
2017/09/19
194-074M
Great Plains Mfg., Inc.
14
Electronic Acremeter
Install Sensor
Refer to Figure 14 (this example depicts the 2S-2600)
4. Select one each new:
16
13 168-491D ACREMETER SWITCH MOUNT
28 221398 SWITCH
13
and two sets new:
22
16
23
20
804-036C
801-067C
804-043C
803-064C
WASHER FLAT 5/16 SAE PLT
SCREW RD HD 8-32 X 1 1/2LG PLT
WASHER LOCK #8
NUT HEX 8-32
and four new:
25 804-088C WASHER FLAT #8 SAE PLT
5. Mount the u-shaped face of the switch mount 13 to
the face of the bearing flangette using the existing
flange bolts 50 , new flat washers 22 and existing
flange nuts 51 .
25
28
25
51
22
23
20
3 50
6. Attach the flat face of the switch mount 13 (part
facing the sensor) using the screws 16 , flat
washers 25 , lock washers 23 and hex nuts 20 .
7.
Attach the pickup sensor to the sensor bracket.
Secure the ground wire to one of the mounting
screws. Slide the sensor so it is no more than 1  8 inch
from the magnet actuator. Do not allow the sensor to
touch the magnet actuator. Leave screws finger tight
until Step 9.
194-074M
Figure 14
Install Sensor (2S-2600)
34818
Note: The individual wire 3 on the sensor is a frame
ground wire that is designed to protect the acre
counter from any static discharge that it may
encounter. It should be attached to the metal on
the drill somewhere.
2017/09/19
Great Plains Mfg., Inc.
Installation Instructions
15
Install Actuator
Refer to Figure 15 (this example depicts the 2S-2600)
8. Orient the actuator 28 so that the snap tabs cannot
entangle debris during rotation (which is top-of-shaftforward for the enumerated drill models on page 1).
Note: The acremeter counts rotations of the ground drive
shaft, this is field traveled acres not field planted
acres.
9. Select one new:
28 540002-1 7/8 HEX SNAP-ON ACTUATOR
Install the two halves of the magnet actuator 3
around the shaft and slide the actuator together.
Position the magnet actuator next to the bearing
mount.
28
Note: Take care when sliding the actuator together to
avoid breaking one of the tabs.
Note: The pulse counter is not rotation direction
sensitive but the position of the sensor to the
spinning magnet actuator is. The sensor should
have the end opposite from the connection
harness towards the shaft and the wide dimension
of the switch housing centered on the plastic
wheel width, 18 inch gap is recommended.
Figure 15
Attach Actuator (2S-2600)
34820
Install Meter
Refer to Figure 16
When mounting the acremeter console to the drill frame,
select a location close to the pickup sensor which
allows easy access for reading or adjustments. Pick a
location which allows the console to be mounted in a
vertical position.
Refer to Figure 16 (this example depicts the 2S-2600)
10. Select a ground driven shaft 1 with easy access.
Select one each new:
27
14
26
29
1
24
18
221422 ELECTRONIC ACRE METER
168-492D ACREMETER MOUNT
806-051C U-BOLT 3/8-16 X 6 1/32 X 7
221399 CONSOLE
and two sets new:
21
19
17
24
18
804-013C WASHER LOCK SPRING 3/8 PLT
803-014C NUT HEX 3/8-16 PLT
802-826C HHCS #10-24X1 1/4 PLT GR5
804-054C WASHER LOCK #10
803-001C NUT HEX 10-24 PLT
On the front face 2 of the main toolbar, attach
mount 14 with U-bolt 26 using lock washer
springs 21 and hex nuts 19 . Attach acremeter 27 to
mount using screws 17 , lock washers 24 and hex
nuts 18 .
11. Connect the cable from the sensor pickup to the acre
counter console. Through the hole in the mount,
windup and tie out of the way any extra cable.
2017/09/19
2
26
27
17
14
19
21
Figure 16
Mount Meter (2S-2600)
34820
194-074M
Great Plains Mfg., Inc.
16
Electronic Acremeter
Acremeter Diagrams
Acre Meter Location 2N-2410, 2N-3010, 2N-2420, 2N-3020
(Effective after October 1, 2016)
Figure 17
2N-2410, 2N3010, 2N-2420, 2N-3020
Kit: 197-187A
194-074M
62039
2017/09/19
Great Plains Mfg., Inc.
Installation Instructions
17
Acre Meter Location 2N-2410, 2N-3010, 2N-2420, 2N-3020
(Effective before October 1, 2016)
Figure 18
2N-2410, 2N3010, 2N-2420, 2N-3020
Kit: 197-187A
2017/09/19
36324
194-074M
Great Plains Mfg., Inc.
18
Electronic Acremeter
Acre Meter Location 606NT
Figure 19
606NT
Kit: 152-327A
194-074M
36325
2017/09/19
Great Plains Mfg., Inc.
Installation Instructions
19
Acre Meter Location 706NT (LH)
Figure 20
706NT
Kit: 152-326A
2017/09/19
36330
194-074M
Great Plains Mfg., Inc.
20
Electronic Acremeter
Acre Meter Location 706NT(RH) Dual Seed/Native Grass
Figure 21
706NT
Kit: 152-328A
194-074M
36331
2017/09/19
Great Plains Mfg., Inc.
Installation Instructions
21
Acre Meter Location 1006NT (LH)
Figure 22
1006NT (LH)
Kit: 152-326A
2017/09/19
36332
194-074M
Great Plains Mfg., Inc.
22
Electronic Acremeter
Acre Meter Location 1006NT (RH)
Figure 23
1006NT (RH)
Kit: 152-326A
194-074M
36333
2017/09/19
Great Plains Mfg., Inc.
Installation Instructions
23
Acre Meter Location 3P500, 3P500 (V), 3P600, 3P606NT
Figure 24
3P500, 3P500 (V), 3P600, 3P606NT
Kit: 152-327A
2017/09/19
36326
194-074M
Great Plains Mfg., Inc.
24
Electronic Acremeter
Acre Meter Location 3P806NT
Figure 25
3P806NT
Kit: 152-327A
194-074M
36327
2017/09/19
Great Plains Mfg., Inc.
Installation Instructions
25
Acre Meter Location 3P1006NT (RH) Dual Seed or Native Grass
also for older drills with two independent drive shafts
Figure 26
3P1006NT (right hand)
Kit: 152-329A
2017/09/19
36328
194-074M
Great Plains Mfg., Inc.
26
Electronic Acremeter
Acre Meter Location 3P1006NT (LH)
Figure 27
3P1006NT (left hand)
Kit: 152-327A
194-074M
36329
2017/09/19
Great Plains Mfg., Inc.
Installation Instructions
27
Acre Meter Location 800 and 1300
Figure 28
800 and 1300
Kit: 175-311A
2017/09/19
36334
194-074M
Great Plains Mfg., Inc.
28
Electronic Acremeter
Acre Meter Location 3PT 1200, 1500, 2000, 2400
Figure 29
3PT 1200, 1500, 2000, 2400
Kit: 118-260A
194-074M
36348
2017/09/19
Great Plains Mfg., Inc.
Installation Instructions
29
Acre Meter Location 3PT 1200, 1500, 2000 Optional
Figure 30
3PT 1200, 1500, 2000
Kit: 118-260A
2017/09/19
36349
194-074M
Great Plains Mfg., Inc.
30
Electronic Acremeter
Acre Meter Location 1206NT Optional
Figure 31
1206NT
Kit: 152-337A
194-074M
38136
2017/09/19
Great Plains Mfg., Inc.
Installation Instructions
31
Acre Meter Location 1205NT Optional
Figure 32
1205NT
Kit: 152-351A
2017/09/19
38121
194-074M
Great Plains Mfg., Inc.
32
Electronic Acremeter
Acre Meter Location NTS2507, NTS2509, & NTS2511 Optional
Figure 33
NTS25 Series
Kit: 313-854A
194-074M
tp-70231
2017/09/19
Great Plains Mfg., Inc.
Installation Instructions
33
Acremeter Kits
Part Lists
The part call-out numbers in this list match all Figures in
these installation instructions. Part descriptions match
those in your updated Parts Manual.
Quantities are units (“ea”).
Kit: 194-073A Models: 2S-2600, 3S-3000, 3S-4000, 3S-5000
ELECTRONIC ACREMETER
Callout
Part Number
11
194-073A
MIN-TILL ELECTRONIC ACRE METER
12
194-074M
MANUAL ELECTRONIC ACRE METER
13
168-491D
ACREMETER SWITCH MOUNT
14
168-492D
ACREMETER MOUNT
15
800-269C
CABLE TIE 33LG
16
801-067C
SCREW RD HD 8-32 X 1 1/2LG PLT
17
802-826C
HHCS #10-24X1 1/4 PLT GR5
18
803-001C
NUT HEX 10-24 PLT
19
803-014C
NUT HEX 3/8-16 PLT
20
803-064C
NUT HEX 8-32
21
804-013C
WASHER LOCK SPRING 3/8 PLT
22
804-036C
WASHER FLAT 5/16 SAE PLT
23
804-043C
WASHER LOCK #8
24
804-054C
WASHER LOCK #10
25
804-088C
WASHER FLAT #8 SAE PLT
26
806-051C
U-BOLT 3/8-16 X 6 1/32 X 7
27
823-423C
ELECTRONIC ACRE METER
28
540002-1
7/8 HEX SNAP-ON ACTUATOR
2017/09/19
Part Description
194-074M
Great Plains Mfg., Inc.
34
Electronic Acremeter
Kit: 197-187A Models: 2N-2410, 2N-3010, 2N-2420, 2N-3020
ELECTRONIC ACREMETER
Callout
Part Number
Part Description
12
194-074M
MANUAL ELECTRONIC ACRE METER
13
168-491D
ACREMETER SWITCH MOUNT
14
168-492D
ACREMETER MOUNT
15
800-269C
CABLE TIE 33LG
16
801-067C
SCREW RD HD 8-32 X 1 1/2LG
19
803-014C
NUT HEX 3/8-16 PLT
20
803-064C
NUT HEX 8-32
21
804-013C
WASHER LOCK SPRING 3/8 PLT
22
804-036C
WASHER FLAT 5/16 SAE PLT
23
804-043C
WASHER LOCK #8
25
804-088C
WASHER FLAT #8 SAE PLT
27
823-423C
ELECTRONIC ACRE METER
31
540003-1
1" RD SNAP-ON ACTUATOR
32
806-266C
U-BOLT 3/8-16 X 8 1/32 X 7
Kit: 152-326A Models: 706NT, 1006NT ELECTRONIC ACREMETER
Callout
Part Number
12
194-074M
MANUAL ELECTRONIC ACRE METER
14
168-492D
ACREMETER MOUNT
16
801-067C
SCREW RD HD 8-32 X 1 1/2LG
20
803-064C
NUT HEX 8-32
21
804-013C
WASHER LOCK SPRING 3/8 PLT
22
804-036C
WASHER FLAT 5/16 SAE PLT
23
804-043C
WASHER LOCK #8
25
804-088C
WASHER FLAT #8 SAE PLT
27
823-423C
ELECTRONIC ACRE METER
33
152-599D
ACREMETER SENSOR MOUNT 2.81
34
540005-1
3/4 HEX SNAP-ON ACTUATOR
35
800-377C
HOSE CLIP 13/16 ID 1/2 MOUNT
36
803-014C
NUT HEX 3/8-16 PLT
37
803-020C
NUT HEX 1/2-13 PLT
38
804-015C
WASHER LOCK SPRING 1/2 PLT
39
806-263C
U-BOLT 3/8-16 X 4 1/32 X 5
194-074M
Part Description
2017/09/19
Great Plains Mfg., Inc.
Installation Instructions
35
Kit: 152-327A Models: 606NT, 3P606NT, 3P806NT, 3P1006NT,
3P500, 3P500V, 3P600
Callout
Part Number
Part Description
12
194-074M
MANUAL ELECTRONIC ACRE METER
14
168-492D
ACREMETER MOUNT
15
800-269C
CABLE TIE 33LG
16
801-067C
SCREW RD HD 8-32 X 1 1/2LG PLT
19
803-014C
NUT HEX 3/8-16 PLT
20
803-064C
NUT HEX 8-32
21
804-013C
WASHER LOCK SPRING 3/8 PLT
22
804-036C
WASHER FLAT 5/16 SAE PLT
23
804-043C
WASHER LOCK #8
25
804-088C
WASHER FLAT #8 SAE PLT
27
823-423C
3P LOUP ACREMETER
43
540002-1
7/8 HEX SNAP-ON ACTUATOR
44
152-601D
7/8 HEX SENSOR MOUNT
45
806-265C
U-BOLT 3/8-16 X 3 1/32 X 5
Kit: 152-329A Models: 3P1006NT DUAL SEED OR NATIVE GRASS
ELECTRONIC ACREMETER
(also earlier model drills with two independent drive shafts)
Callout
Part Number
12
194-074M
MANUAL ELECTRONIC ACRE METER
15
800-269C
CABLE TIE 33LG
16
801-067C
SCREW RD HD 8-32 X 1 1/2LG
20
803-064C
NUT HEX 8-32
22
804-036C
WASHER FLAT 5/16 SAE PLT
23
804-043C
WASHER LOCK #8
25
804-088C
WASHER FLAT #8 SAE PLT
27
823-423C
3P LOUP ACREMETER
28
221398
43
540002-1
7/8 HEX SNAP-ON ACTUATOR
44
152-601D
7/8 HEX SENSOR MOUNT
62
823-434C
HARNESS EXT. 10’ 2 PIN WP
63
152-329A
3P DUAL SEED/NG ACREMETER
2017/09/19
Part Description
SWITCH
194-074M
Great Plains Mfg., Inc.
36
Electronic Acremeter
Kit: 175-311A Models: 800 and 1300 ELECTRONIC ACREMETER
Callout
Part Number
Part Description
12
194-074M
MANUAL ELECTRONIC ACRE METER
14
168-492D
ACREMETER MOUNT
15
800-269C
CABLE TIE 33LG
16
801-067C
SCREW RD HD 8-32 X 1 1/2LG PLT
19
803-014C
NUT HEX 3/8-16 PLT
20
803-064C
NUT HEX 8-32
21
804-013C
WASHER LOCK SPRING 3/8 PLT
22
804-036C
WASHER FLAT 5/16 SAE PLT
23
804-043C
WASHER LOCK #8
25
804-088C
WASHER FLAT #8 SAE PLT
27
823-423C
3P LOUP ACREMETER
43
540002-1
7/8 HEX SNAP-ON ACTUATOR
46
175-489D
EW SENSOR MOUNT
47
806-264C
U-BOLT 3/8-16 X 5 1/32 X 5
Kit: 118-260A Models: 3PT 1200,1210,1220/3-PT 1500,1510,
1520/3-PT 2000,2010,2020/3PT 2400
Callout
Part Number
12
194-074M
MANUAL ELECTRONIC ACRE METER
14
168-492D
ACREMETER MOUNT
16
801-067C
SCREW RD HD 8-32 X 1 1/2LG PLT
19
803-014C
NUT HEX 3/8-16 PLT
20
803-064C
NUT HEX 8-32
21
804-013C
WASHER LOCK SPRING 3/8 PLT
22
804-036C
WASHER FLAT 5/16 SAE PLT
23
804-043C
WASHER LOCK #8
25
804-088C
WASHER FLAT #8 SAE PLT
26
806-051C
U-BOLT 3/8-16 X 6 1/32 X 7
27
823-423C
ELECTRONIC ACRE METER
40
118-071D
3PT ACREMETER SWITCH MOUNT
41
540005-1
3/4 HEX SNAP-ON ACTUATOR
42
802-128C
HHCS 1/2-13X2 GR5
194-074M
Part Description
2017/09/19
Great Plains Mfg., Inc.
Installation Instructions
37
Kit: 152-328A Models: 706NT, 1006NT DUAL SEED OR NATIVE GRASS
ELECTRONIC ACREMETER
Callout
Part Number
12
194-074M
MANUAL ELECTRONIC ACRE METER
15
800-269C
CABLE TIE 33LG
16
801-067C
SCREW RD HD 8-32 X 1 1/2LG
19
803-014C
NUT HEX 3/8-16 PLT
20
803-064C
NUT HEX 8-32
21
804-013C
WASHER LOCK SPRING 3/8 PLT
23
804-043C
WASHER LOCK #8
25
804-088C
WASHER FLAT #8 SAE PLT
27
823-423C
3P LOUP ACREMETER
39
806-263C
U-BOLT 3/8-16 X 4 1/32 X 5
48
152-600D
NG/DUAL SENSOR MOUNT
49
197-164H
ACREMETER HUB WELDMENT
50
221398
51
540004-1
1 1/4 RD SNAP-ON ACTUATOR
52
800-141C
SNAP RING EXT F/PEERLESS G.
53
800-377C
HOSE CLIP 13/16 ID 1/2 MOUNT
54
802-078C
HHCS 1/4-20X5/8 GR5
55
802-258C
HHCS 1/2-13X1 GR5
56
803-020C
NUT HEX 1/2-13 PLT
57
804-007C
WASHER FLAT 1/4 SAE PLT
58
804-015C
WASHER LOCK SPRING 1/2 PLT
59
823-434C
HARNESS EXT. 10’ 2 PIN WP
60
890-849C
SPLINED ACREMETER MOUNT
61
152-328A
NO-TILL DUAL SEED/NG ACREME
2017/09/19
Part Description
SWITCH
194-074M
Great Plains Mfg., Inc.
38
Electronic Acremeter
Kit: 152-337A Models: 1206NT ELECTRONIC ACREMETER
Callout
Part Number
Part Description
1
152-605D
1206NT ACRE SENSOR MOUNT
2
168-492D
ACREMETER MOUNT
3
540005-1
3/4 HEX SNAP-ON ACTUATOR
4
800-112C
CABLE TIE .19 X .25 1.75D 50LB
5
800-167C
HOSE CLAMP 3/8 ID
6
800-377C
HOSE CLIP 13/16 ID 1/2 MOUNT
7
801-067C
SCREW RD HD 8-32 X 1 1/2LG PLT
8
803-014C
NUT HEX 3/8-16 PLT
9
803-064C
NUT HEX 8-32
10
804-013C
WASHER LOCK SPRING 3/8 PLT
11
804-043C
WASHER LOCK #8
12
8040-088C
13
806-263C
U-BOLT 3/8-16 X 4 1/32 X 5
14
823-423C
ELECTRONIC ACRE METER
WASHER FLAT #8 SAE PLT
Kit: 152-351A Models: 1205NT ELECTRONIC ACREMETER
Callout
Part Number
1
152-604D
1206NT LOWER HEX JACK SHAFT
2
152-605D
1206NT ACRE SENSOR MOUNT
3
168-492D
ACREMETER MOUNT
4
540005-1
3/4 HEX SNAP-ON ACTUATOR
5
800-112C
CABLE TIE .19 X .25 1.75D 50LB
6
800-167C
HOSE CLAMP 3/8 ID
7
800-377C
HOSE CLIP 13/16 ID 1/2 MOUNT
8
801-067C
SCREW RD HD 8-32 X 1 1/2LG PLT
9
803-014C
NUT HEX 3/8-16 PLT
10
803-064C
NUT HEX 8-32
11
804-013C
WASHER LOCK SPRING 3/8 PLT
12
804-043C
WASHER LOCK #8
13
804-088C
WASHER FLAT #8 SAE PLT
14
806-263C
U-BOLT 3/8-16 X 4 1/32 X 5
15
823-423C
ELECTRONIC ACRE METER
194-074M
Part Description
2017/09/19
Great Plains Mfg., Inc.
Installation Instructions
39
Kit: 318-854A Models: NTS2507, NTS2509, & NTS2511 ELECTRONIC ACREMETER
Item
Part Number
Part Description
N/A*
22142
N/A*
221398A
N/A*
329-233D
ACRE METER READER MNT NTS
N/A*
540004-1
1 1/4 RD SNAP-ON ACTUATOR
N/A*
800-112C
CABLE TIE .19X7.25 1.75D 50LB
N/A*
801-016C
SCREW RD HD 8-32 X 1/2 LG PLT
N/A*
801-167C
SCREW RD HD 8-32 X 1 1/2LG PLT
N/A*
802-004C
HHCS 1/4-20X3/4 GR5
N/A*
803-006C
NUT HEX 1/4-20 PLT
N/A*
803-064C
NUT HEX 8-32
N/A*
804-006C
WASHER LOCK SPRING 1/4 PLT
N/A*
804-043C
WASHER LOCK #8
N/A*
804-088C
WASHER FLAT #8 SAE PLT
CONSOLE FOR ACRE METER 823-423
ACRE COUNTER PICKUP
* Refer to No-Till Seeder Parts Manual for illustration and item numbers.
Abbreviations
EA
Each
GR
Grade 5
HD
Head
HHCS
Hex Head Cap Screw
LCD
Liquid Crystal Display
LED
Light-Emitting Diode
2017/09/19
LG
MIN-TILL
PLT
RD
SAE
Long
Minimum Tillage
Plated
Round
Society of Automotive Engineers (standard)
194-074M
Great Plains Mfg., Inc.
40
Electronic Acremeter
Great Plains Manufacturing, Inc.
Corporate Office P.O. Box 5060
Salina, Kansas 67402-5060 USA
194-074M
2017/09/19
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement