Desa R35E Construction Heaters Owner manual

Desa R35E Construction Heaters Owner manual
PORTABLE
FORCED
AIR HEATER
OWNER’S MANUAL
Heater Sizes:
35,000 and 55,000 Btu/Hr
H.S.I. Series
IMPORTANT: Read and understand this manual before assembling, starting, or servicing heater. Improper use of heater can cause serious injury.
Keep this manual for future reference.
ARL LOGO
®
G 004
35,000 And 55,000 Btu/Hr H.S.I. Series
PORTABLE FORCED AIR HEATERS
SAFETY
INFORMATION
WARNINGS
IMPORTANT: Read this Owner’s
Manual carefully and completely
before trying to assemble, operate, or service this heater. Improper use of this heater can
cause serious injury or death from
burns, fire, explosion, electrical
shock, and carbon monoxide
poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
Carbon Monoxide Poisoning: Early
signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness,
and/or nausea. If you have these signs, the
heater may not be working properly. Get
fresh air at once! Have heater serviced.
Some people are more affected by carbon
monoxide than others. These include pregnant women, persons with heart or lung
disease or anemia, those under the influence
of alcohol, and those at high altitudes.
Make certain you read and understand all
Warnings. Keep this manual for reference.
It is your guide to safe and proper operation
of this heater.
• Use only kerosene or No. 1 fuel oil to
avoid risk of fire or explosion. Never use
gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels.
• Fueling
a) Personnel involved with fueling shall
be qualified and thoroughly familiar
with the manufacturer’s instructions
and applicable federal, state, and local regulations regarding the safe
fueling of heating units.
•
•
•
b)Only the type of fuel specified on the
heater’s data plate shall be used.
c) All flame, including the pilot light, if
any, shall be extinguished and the heater
allowed to cool, prior to fueling.
d)During fueling, all fuel lines and fuelline connections shall be inspected for
leaks. Any leaks shall be repaired prior
to returning the heater to service.
e) At no time shall more than one day’s
supply of heater fuel be stored inside
a building in the vicinity of the heater.
Bulk fuel storage shall be outside the
structure.
f) All fuel storage shall be located a
minimum of 25 feet from heaters,
torches, welding equipment, and
similar sources of ignition (exception: the fuel reservoir integral with
the heater unit).
g)Whenever possible, fuel storage shall
be confined to areas where floor penetrations do not permit fuel to drip
onto or be ignited by a fire at lower
elevation.
h)Fuel storage shall be in accordance
with the federal, state, or local authority having jurisdiction.
Never use heater where gasoline, paint
thinner, or other highly flammable vapors are present.
Follow all local ordinances and codes
when using heater.
Heaters used in the vicinity of tarpaulins, canvas, or similar enclosure materials shall be located a safe distance
from such materials. The recommended
minimum safe distance is 10 feet. It is
further recommended that these enclosure materials be of a fire retardant nature. These enclosure materials shall be
securely fastened to prevent them from
igniting or from upsetting the heater
due to wind action.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
UNPACKING
1.
2.
3.
2
Use only in well-vented areas. Before
using heater, provide at least a threesquare-foot opening of fresh, outside
air for each 100,000 Btu/Hr of rating.
This heater produces carbon monoxide,
which is listed by the State of California as a reproductive toxin under Proposition 65.
Use only in places free of flammable
vapors or high dust content.
Use only the electrical voltage and frequency specified on model plate.
Use only a three-prong, grounded extension cord.
Minimum heater clearances from combustibles:
Outlet: 8 Ft. Sides: 4 Ft.
Top: 4 Ft. Rear: 4 Ft.
Locate heater on a stable and level surface if heater is hot or running or a fire
may occur.
When moving or storing heater, keep
heater in a level position or fuel spillage may occur.
Keep children and animals away from
heater.
Unplug heater when not in use.
When used with thermostat, heater may
start anytime.
Never use heater in living or sleeping
areas.
Never block air inlet (rear) or air outlet
(front) of heater.
Never move, handle, refuel, or service
a hot, operating, or plugged-in heater.
Never attach duct work to front or rear
of heater.
Remove all packing items applied to
heater for shipment.
Remove all items from carton.
Check items for shipping damage. If
heater is damaged, promptly inform
dealer where you bought heater.
104687
OWNER’S MANUAL
PRODUCT IDENTIFICATION
FUELS
WARNING: Use only kerosene
or No. 1 fuel oil to avoid risk of fire
or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable
fuels.
Handle
Hot Air Outlet
Upper Shell
Fan Guard
Lower Shell
Air Filter
End Cover
Fuel Tank
Fuel Cap
Side Cover
Ignition Control Assembly
(assembly on inside of side cover)
Power Cord
THEORY OF OPERATION
The Air System: The motor turns the fan.
The fan pushes air into and around the
combustion chamber. This air is heated and
provides a stream of clean, hot air.
Combustion Chamber
The Ignition System: The ignition control assembly provides power to the ignitor.
This ignites the fuel/air mixture in the combustion chamber.
The Flame-Out Control System: This
system causes the heater to shut down if the
flame goes out.
Air Pump
Air Intake
Filter
Motor
Ignitor
Fan
Clean
Heated
Air Out
Cool
Air In
Air
Output
Filter
Fuel
Tank
Nozzle
Fuel
Filter
Air For Fuel System
Ignition Control
Assembly
Air Line
To Burner
Air For Combustion
And Heating
Fuel
Figure 2 - Cross Section Operational View
104687
IMPORTANT: Use a KEROSENE ONLY
storage container. Be sure storage container is
clean. Foreign matter such as rust, dirt, or
water will cause the ignition control assembly
to shut down the heater. Foreign matter may
also require you to clean fuel system often.
VENTILATION
Figure 1 - 35,000 Btu/Hr Model
The Fuel System: The air pump forces
air through the air line. The air is then
pushed through the nozzle. This air causes
fuel to lift from the tank. A fine mist of fuel
is sprayed into the combustion chamber.
Do not use heavy fuels such as No. 2 fuel oil
or No. 2 Diesel. Using heavy fuels will
result in a clogged fuel filter and/or nozzle.
3
Follow the minimum fresh,
outside
air
ventilation
requirements. If proper fresh,
outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide proper
fresh, outside air ventilation before running heater.
Provide at least a three-square-foot opening
of fresh, outside air for each 100,000 Btu/Hr
rating. Provide extra fresh air if more heaters are being used.
Example: A 55,000 Btu/Hr heater requires
one of the following:
• a two-car garage door (16 feet wide opening) raised 1 1/2 inches
• a single-car garage door (9 feet wide
opening) raised 2 1/2 inches
• two windows (30 inches wide opening)
raised 4 1/2 inches
35,000 And 55,000 Btu/Hr H.S.I. Series
PORTABLE FORCED AIR HEATERS
OPERATION
WARNING: Review and understand the warnings in the
Safety Information section, page
2. They are needed to safely operate this heater. Follow all local
codes when using this heater.
5.
TO START HEATER
1.
2.
3.
4.
Follow all ventilation and safety information.
Fill fuel tank with kerosene or No. 1
fuel oil.
Attach fuel cap.
Plug power cord of heater into threeprong, grounded extension cord. Extension cord must be at least six feet long.
Extension Cord Wire Size Requirements
• 6 to 10 feet long, use 18 AWG rated
cord
• 11 to 100 feet long, use 16 AWG
rated cord
• 101 to 200 feet long, use 14 AWG
rated cord
Plug extension cord into standard 120
volt/60 hertz, three-hole, grounded outlet. Note: Ignitor will preheat for five
seconds then heater will start.
TO STOP HEATER
Unplug extension cord from outlet.
TO RESET HEATER
1.
2.
Unplug extension cord from outlet and
wait 10 seconds (two minutes if heater
has been running).
Plug extension cord into standard 120
volt/60 hertz, three-hole, grounded outlet. Note: Ignitor will preheat for five
seconds then heater will start.
STORING,
TRANSPORTING,
OR SHIPPING
Note: If shipping, transport companies require fuel tanks to be empty.
1. Drain fuel tank. Drain fuel through fuel
cap opening. Be sure all fuel is removed.
2. If any debris is noted in old fuel, add 1
or 2 quarts of clean kerosene to tank,
stir, and drain again. This will prevent
excess debris from clogging filters during future use.
3. Replace fuel cap. Properly dispose of old
and dirty fuel. Check with local automotive service stations that recycle oil.
4. If storing, store heater in dry place.
Make sure storage place is free of dust
and corrosive fumes.
IMPORTANT: Do not store kerosene over
summer months for use during next heating
season. Using old fuel could damage heater.
PREVENTATIVE MAINTENANCE SCHEDULE
WARNING: Never service heater while it is plugged in, operating, or
hot. Severe burns and electrical shock can occur.
Item
How Often
How To
Fuel tank
Flush every 150-200 hours of operation or
as needed.
See Storing, Transporting, or Shipping,
above.
Air output and lint filters
Replace every 500 hours of operation or
once a year.
See Air Output, Air Intake, and Lint Filters,
page 6.
Air intake filter
Wash and dry with soap an water every 500
hours of operation or replace as needed.
See Air Output, Air Intake, and Lint Filters,
page 6.
Fuel filter
Clean twice a heating season or replace as
needed.
See Fuel Filter, page 7.
Ignitor
No maintenance required.
Fan blades
Clean each season or as needed.
Motor
Not required/permanently lubricated
4
See Fan, page 6.
104687
OWNER’S MANUAL
TROUBLESHOOTING
WARNING: Never service heater while it is plugged in, operating, or
hot. Severe burns and electrical shock can occur.
FAULT CONDITION
POSSIBLE CAUSE
REMEDY
Motor does not start five seconds after heater
is plugged in.
1. No power to heater
1. Check circuit breaker in electrical panel.
WARNING: High voltage!
2. Bad electrical connection between motor and ignition control assembly or ignition control assembly and power cord
3. Blown fuse on ignition control assembly
4. Binding pump rotor
Motor starts and runs but heater does not
ignite.
2. Check all electrical connections. See
Wiring Diagrams, page 10.
5. Defective ignition control assembly
6. Defective motor
3. See Ignitor, page 7.
4. If fan does not turn freely, see Pump Rotor, page 8.
5. Replace ignition control assembly.
6. Replace motor.
1.
2.
3.
4.
5.
1.
2.
3.
4.
5.
No fuel in tank
Pump pressure incorrect
Dirty fuel filter
Obstruction in nozzle
Water in fuel tank
Fill tank with kerosene.
See Pump Pressure Adjustment, page 6.
See Fuel Filter, page 7.
See Nozzle Assembly, page 8.
Drain and flush fuel tank with clean
kerosene. See Storing, Transporting, or
Shipping, page 4.
WARNING: High voltage!
Heater ignites but ignition control assembly
shuts heater off after a short period of time.
6. Bad electrical connection between ignitor and ignition control assembly
7. Defective ignitor
8. Defective ignition control assembly
6. Check electrical connections. See Wiring Diagrams, page 10.
7. Replace ignitor, see page 7.
8. Replace ignition control assembly.
1. Pump pressure incorrect
2. Dirty air intake, air output, and/or lint
filter
3. Dirty fuel filter
4. Obstruction in nozzle
5. Photocell assembly not properly installed (not seeing the flame)
1. See Pump Pressure Adjustment, page 6.
2. See Air Output, Air Intake, and Lint Filters, page 6.
3. See Fuel Filter, page 7.
4. See Nozzle Assembly, page 8.
5. Make sure photocell boot is properly
seated in bracket.
WARNING: High voltage!
6. Dirty photocell lens
7. Bad electrical connection between photocell and ignition control assembly
8. Defective photocell
9. Defective ignition control assembly
104687
5
6. Clean photocell lenses.
7. Check electrical connections. See Wiring Diagrams, page 10.
8. Replace photocell
9. Replace ignition control assembly.
35,000 And 55,000 Btu/Hr H.S.I. Series
PORTABLE FORCED AIR HEATERS
PUMP PRESSURE
ADJUSTMENT
SERVICE
PROCEDURES
Fan
WARNING: Never service
heater while it is plugged in, operating, or hot. Severe burns and
electrical shock can occur.
1.
Motor
2.
3.
Flush
UPPER SHELL REMOVAL
1.
2.
3.
4.
Remove screws along each side of
heater using 5/16" nut-driver. These
screws attach upper and lower shells
together.
Lift upper shell off.
Remove fan guard.
Motor
Shaft
Setscrew
5.
6.
Figure 4 - Fan Cross Section
Upper
Shell
Fan
Guard
AIR OUTPUT, AIR INTAKE,
AND LINT FILTERS
1.
2.
3.
4.
5.
Figure 3 - Upper Shell Removal
FAN
IMPORTANT: Remove fan from motor
shaft before removing motor from heater.
The weight of the motor resting on the fan
could damage the fan pitch.
1. Remove upper shell (see above).
2. Use 1/8" Allen wrench to loosen setscrew which holds fan to motor shaft.
3. Slip fan off motor shaft.
4. Clean fan using soft cloth moistened
with kerosene or solvent.
5. Dry fan thoroughly.
6. Replace fan on motor shaft. Place fan
hub flush with end of motor shaft (see
Figure 4).
7. Place setscrew on flat of shaft. Tighten
setscrew firmly (40-50 inch-pounds).
8. Replace fan guard and upper shell.
6.
7.
Remove upper shell (see Upper Shell
Removal).
Remove filter end cover screws using
5/16" nut-driver.
Remove filter end cover.
Replace air output and lint filters.
Wash or replace air intake filter (see
Preventative Maintenance Schedule,
page 4).
Replace filter end cover.
Replace fan guard and upper shell.
IMPORTANT: Do not oil filters.
Air Intake Filter
Remove pressure gauge plug from filter
end cover.
Install accessory pressure gauge (part
number HA1180).
Start heater (see Operation, page 4).
Allow motor to reach full speed.
Using a flat blade screwdriver, adjust
pressure. Turn relief valve to right to
increase the pressure. Turn relief valve
to left to decrease the pressure. Set
pump pressure as follows:
35 Model: 3.0 psi
55 Model: 3.4 psi
Stop heater (see Operation, page 4).
Remove pressure gauge. Replace pressure gauge plug in filter end cover.
Pressure
Gauge
Plug
Relief
Valve
Figure 6 - Pressure Gauge Plug Removal
Filter End Cover
Fan Guard
Pressure
Gauge
Lint Filter
Air Output Filter
Figure 5 - Air Output, Air Intake, and Lint
Filters
6
Figure 7 - Adjusting Pump Pressure
104687
OWNER’S MANUAL
SERVICE
PROCEDURES
Continued
WARNING: Never service
heater while it is plugged in, operating, or hot. Severe burns and
electrical shock can occur.
IGNITOR
1.
2.
3.
4.
FUEL FILTER
1.
2.
3.
4.
5.
6.
7.
Remove 4 side cover screws using
5/16" nut-driver.
Remove side cover.
Pull upper fuel line off fuel filter neck.
Carefully pry bushing and fuel filter out
of fuel tank.
Wash fuel filter with clean fuel and replace in tank.
Attach upper fuel line to fuel filter neck.
Replace side cover.
Fuel Filter
5.
6.
7.
Remove upper shell and fan guard (see
page 6).
Remove fan (see page 6).
Remove 4 side cover screws with a
5/16" nut driver. Remove side cover
(see Figure 8).
Disconnect ignitor wires (gray) from
ignition control assembly (see Figure
9). Pull the ignitor wires up through the
hole in the lower shell.
Disconnect fuel line hose and air line
hose. Remove photocell from photocell
bracket (see Figure 9).
Remove combustion chamber. Stand
combustion chamber on end with
nozzle adapter bracket on top (see Figure 10).
Remove ignitor screw with a 1/4" nut
driver. Carefully remove ignitor from
nozzle adapter bracket.
Combustion
Chamber
Nozzle
Adapter
Bracket
CAUTION: Do not bend or strike
ignitor element. Handle with care.
8.
9.
10.
11.
12.
13.
14.
15.
16.
Carefully remove replacement ignitor
from styrofoam packing.
Carefully guide ignitor into opening in
nozzle adapter bracket. Do not strike
ignitor element. Attach ignitor to
nozzle adapter bracket with screw using a 1/4" nut driver (see Figure 10).
Torque 8 to 15 in. lbs. Do not over
torque.
Replace combustion chamber.
Route the ignitor wires back down
through the hole in the lower shell.
Connect wires to the ignition control
assembly.
Replace side cover (see Figure 8).
Connect and route fuel line hose and air
line hose to nozzle adapter (see Figure 9).
Replace photocell in photocell bracket.
Route wires as shown in Figure 12, page 8.
Replace fan (see page 6).
Replace fan guard and upper shell (see
page 6).
Ignitor
Screw/
Washer
Assembly
Ignitor
Air
Line
Hose
Ignitor
Wires
Ignitor
Element
Fuel
Line
Hose
Side Cover
Upper Fuel Line
Figure 8 - Fuel Filter Removal
Photocell
Bracket
Ignitor
Nozzle
Adapter
Bracket
Ignition
Control
Assembly
Photocell
Bracket
Photocell
Assembly
Side Cover
Figure 9 - Disconnecting Ignitor Wires
from Ignition Control Assembly (see
Wiring Diagram, Figure 18 or 19
appropriately, page 10)
Combustion
Chamber
Nozzle Adapter
Bracket Opening
Figure 10 - Ignitor Replacement
Continued
104687
7
35,000 And 55,000 Btu/Hr H.S.I. Series
PORTABLE FORCED AIR HEATERS
Nozzle Face
SERVICE
PROCEDURES
Combustion
Chamber
Continued
NOZZLE ASSEMBLY
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
Remove upper shell (see page 6).
Remove fan (see page 6).
Remove fuel and air line hoses from
nozzle assembly (see Figure 12).
Turn nozzle assembly 1/4 turn to left
and pull toward motor to remove (see
Figure 13).
Place plastic hex-body into vise and
lightly tighten.
Carefully remove nozzle from the
nozzle adapter using 5/8" socket
wrench (see Figure 14).
Blow compressed air through face of
nozzle. This will free any dirt in
nozzle area.
Inspect nozzle seal for damage.
Replace nozzle into nozzle adapter until nozzle seats. Tighten 1/3 turn more
using 5/8" socket wrench (40-45 inchpounds).
Attach nozzle assembly to burner strap.
Attach and route fuel and airline hoses
to nozzle assembly as shown (see Figure 12). Route photocell wires as shown
in Figure 12.
Replace fan (see page 6).
Replace fan guard and upper shell.
Figure 13 - Removing Nozzle/Adapter
Assembly
3.
4.
5.
6.
7.
8.
9.
Nozzle/
Adapter
Assembly
Air Line Hose
Blade
Pump Plate
Air Intake Filter
(Procedure if Rotor is Binding)
1.
2.
15.
16.
Remove upper shell (see page 6).
Remove filter end cover screws using
5/16" nut-driver.
Remove filter end cover and air filters.
Remove pump plate screws using 5/16"
nut-driver.
Remove pump plate.
Remove rotor, insert, and blades.
Check for debris in pump. If debris is
found, blow out with compressed air.
Install insert and rotor.
Check gap on rotor. Adjust to
.003"/.004" if needed (see Figure 16).
Note: Rotate rotor one full turn to insure the gap is .003"/.004" at tightest
position. Adjust if needed.
Install blades, pump plate, air filters,
and filter end cover.
Replace fan guard and upper shell.
Adjust pump pressure (see page 6).
Note: If rotor is still binding, proceed
as follows.
Perform steps 1 through 6 above.
Place fine grade sandpaper (600 grit)
on flat surface. Sand rotor lightly in
“figure 8” motion four times (see Figure 17).
Reinstall insert and rotor.
Perform steps 10 through 12 above.
Fuel Line
Fitting
Figure 14 - Nozzle and Nozzle Adapter
PUMP ROTOR
13.
14.
Photocell
Wires
Nozzle
Air Line
Fitting
11.
12.
Burner
Strap
Nozzle Seal
Nozzle
Adapter
10.
Combustion
Chamber
Nozzle/
Adapter
Assembly
Filter End
Cover
Insert
Rotor
Air Output
Filter
Fan Guard
Figure 15 - Rotor Location
Gap Adjusting Screw
Blade
.003"/.004"
Gap
Measured
With
Feeler
Gauge
Rotor
Gap Adjusting Screw
Figure 16 - Gap Adjusting Screw
Locations
Sandpaper
Fuel Line
Hose
Figure 12 - Removing Air and Fuel Line
Hoses
Figure 17 - Sanding Rotor
8
104687
OWNER’S MANUAL
SPECIFICATIONS
Output Rating (Btu/Hr)
Fuel
Fuel Tank Capacity (U.S. Gal.)
Fuel Consumption (Gal. Per Hr.)
Pump Pressure (p.s.i.)
Electric Requirements
Amperage (Normal Run)
Hot Air Output (CFM)
Motor RPM
Motor HP
Shipping Weight
(Approximate Pounds)
Heater Weight without Fuel
(Approximate Pounds)
35,000
55,000
Use Only Kerosene or No. 1 Fuel Oil
3.0
5.0
.30
.44
3.0
3.4
120 V/60 Hz
2.0
2.0
170
180
1725
1725
1/15
1/15
35
35
30
30
TECHNICAL
SERVICE
REPLACEMENT
PARTS
Note: Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call DESA International’s Technical Service Dept. at 1-800-323-5190.
When calling DESA International, have
ready:
• your name
• your address
• model number of your heater
• how heater was malfunctioning
• purchase date
Usually, we will ask you to return the defective part to the factory.
PARTS NOT UNDER
WARRANTY
You may have further questions about operation or troubleshooting. If so, contact
DESA International’s Technical Service
Dept. at 1-800-323-5190.
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call DESA International’s Parts
Department at 1-800-972-7879 for referral
information. Parts Centrals are listed in the
Authorized Service Center booklet supplied
with heater.
When calling DESA International, have
ready:
• model number of your heater
• the replacement part number
104687
9
35,000 And 55,000 Btu/Hr H.S.I. Series
PORTABLE FORCED AIR HEATERS
WIRING DIAGRAM
Ignitor
Gray
IGNITOR
Red
MOTOR MAIN
Gray
Ignition Control
Assembly
Motor Green
Power Plug
120V/60Hz
Green
Black
120V (L1)
White
AC NEUTRAL (L2)
MOTOR RETURN
White
Photocell
Blue
PHOTOCELL
Blue
PHOTOCELL
104040
IGNITOR
Figure 18 - Wiring Diagram for Heaters Using 104040-02 Ignition Control Assembly
Ignitor
Gray
Gray
Black
IGNITOR
L1 (120V)
Red
MOTOR MAIN
IGNITOR
Motor Green
Power Plug
120V/60Hz
White
Green
Blue
Ignition Control
Assembly
MOTOR RETURN
Photocell
Blue
White
PHOTOCELL
L2 AC NEUTRAL
PART# 102350
PHOTOCELL
Figure 19 - Wiring Diagram for Heaters Using 102350-01 Ignition Control Assembly
10
104687
OWNER’S MANUAL
ACCESSORIES
Purchase accessories and parts from your
nearest dealer or service center. If they can
not supply these accessories or parts, either
contact your nearest Parts Central or DESA
International's Parts Department at 1-800972-7879 for referral information. Parts Centrals are listed in the Authorized Service
Center booklet supplied with heater.
THERMOSTAT KIT - HA1210
Keeps your building at the temperature you
select day and night. Helps economize on fuel.
AIR GAUGE KIT - HA1180
Special tool to check pump pressure.
HEAVY DUTY WHEELS AND
HANDLE KIT - HA1202
For heavy duty applications. Makes your
heater even more portable and convenient.
STANDARD WHEELS AND
HANDLE KIT - HA1206
Makes heater even more portable and convenient. Easy to assemble.
A 008
IGNITION CONTROL
ASSEMBLY/PHOTOCELL
TESTER - HA1170
Special tool used to test the ignition control
assembly and photocell.
104687
11
35,000 And 55,000 Btu/Hr H.S.I. Series
PORTABLE FORCED AIR HEATERS
ILLUSTRATED
PARTS
BREAKDOWN
4
1
2
5
REM35C
REM55B
R35E
R55B
9-1
36
9-2
9-5
3
9
7
6
11
9-4
9-3
8
21
10
12
18
13
20
22
16
23
24
25
28
26
27
30
29
35
34
12-1
19
12-2
17
12-3
15
12-4
12-5
31
33
32
14
12-6
12-7
12-18
12-17
12-16
12-8
12-9
12-15
12-14
12-10
Motor and Pump Assembly
12-12
12
12-11
104687
OWNER’S MANUAL
PARTS LIST
This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct
model and serial numbers (from the model plate), then the part number and description of the desired part.
REM35C
REM55B
R35E
R55B
KEY
NO.
PART
NUMBER
DESCRIPTION
1
2
M51104-01
098511-36
098511-67
M11084-29
100647-01
098512-58
098512-50
M10908-2
103154-01
M16656-23
∆
HA3006
100735-17
102548-01
104056-01
102336-01
104023-01
M11084-26
103684-01
∆
102001-01
079975-02
079975-03
M22009**, ***
M22456-1**
M22456-2***
M29608
M29632 ⊕
M29633 ⊕
M29609
M12461-31
M27694 ∞
M10993-1 ∞
M22997 ∞
M8940 ∞
M29612-01 ⊕
M12461-31
Handle
Upper Shell (White)
Upper Shell (Black)
Screw, #10-16 x 3/4"
Screw, #10-16 x 1/2"
Combustion Chamber (35 Model)
Combustion Chamber (55 Model)
Screw, #6-32 x 3/8"
Photocell Bracket
Photocell Assembly
Burner Head Assembly
Nozzle Assembly (35 Model)
Nozzle Assembly (55 Model)
Ignitor Kit
Nozzle Adapter
Nozzle Adapter Bracket
Screw/Washer Assembly
Screw, #10-16 x 3/8"
Fan
Motor and Pump Assembly
Motor
Pump Body (35 Model)
Pump Body (55 Model)
Insert
Rotor (35 Model)
Rotor (55 Model)
Pump End Cover
Lint Filter
Intake Filter
Filter End Cover
Screw, #10-32 x 1"
Adjusting Screw
Pressure Relief Spring
Plug
Steel Ball, 1/4" Diameter
Output Filter
Screw, #10-32 x 1" (35 Model)
3
4
5
6
7
8
9
9-1
9-2
9-3
9-4
9-5
10
11
12
12-1
12-2
12-3
12-4
12-5
12-6
12-7
12-8
12-9
12-10
12-11
12-12
12-13
12-14
12-15
∆
Not available as an assembly
** Included in Rotor Kit (Part No. HA3004)
*** Included in Rotor Kit (Part No. HA3005)
104687
KEY
NO.
QTY.
⊕
∞
1
1
1
2
6
1
1
2
1
1
1
1
PART
NUMBER
M12461-32
103676-01
M8643**
M8643-2***
12-18
FHPF3-5C
FHPF3-6C
13
M51105-01
14
098219-31
15
M11143-1
16
NTC-4C
17
M11084-26
18
M50631
19
097461-03AA
20
101205-01
21
M30865-02
22
M11271-8
23
M50104-02
24
M11084-26
25
M10908-14
26
098511-18
098511-81
27
M50814-06
28
079973-01
29
M50876-04
M50876-05
30
M10990-3
31
101695-01
32
102349-01
33
104068-03
34
097702-01
35
098513-23
098513-62
36
M51108-01
12-16
12-17
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
3
1
1
1
1
1
6
DESCRIPTION
QTY.
1
Screw #10-32 x 1 /8" (55 Model)
Nylon Elbow, 90°
Blade (35 Model)
Blade (55 Model)
Screw, (35 Model)
Screw, (55 Model)
Fan Guard
Power Cord
Strain Relief Bushing
Hex Lock Nut, 1/4-20
Screw, #10-16 x 3/8"
Rubber Bumper
Side Cover
Motor Bracket
Bushing
Clip Nut
Bushing
Screw, #10-16 x 3/8"
Screw, #8-32 x 3/8"
Lower Shell (White)
Lower Shell (Black)
Rubber Airline
Fuel Line
Fuel Filter (with bushing, 35 Mod.)
Fuel Filter (with bushing, 55 Mod.)
Rubber Bushing
Button Plug
PCB Support
Ignition Control Assembly
Fuel Cap (Includes Gasket)
Fuel Tank (35 Model)
Fuel Tank (55 Model)
Shell Heat-Shield
6
1
4
4
2
2
1
1
1
2
4
2
1
1
2
6
1
6
1
1
1
1
1
1
1
1
1
5
1
1
1
1
1
PARTS AVAILABLE - NOT SHOWN
098493-01
103814-01
General Information Decal
Wire Tie
Included in Filter Kit (Part No. HA3014)
Included in Pump Adjustment Kit (Part No. HA3020)
13
1
1
WARRANTY AND REPAIR SERVICE
KEEP THIS WARRANTY
Model No.
Serial No.
Date of Purchase
(To be filled in by purchaser)
LIMITED WARRANTY
DESA International warrants this product and any parts thereof, to be free from defects in materials and workmanship for one (1) year from
the date of first purchase when operated and maintained in accordance with instructions. This warranty is extended only to the original retail
purchaser, when proof of purchase is provided.
This warranty covers only the cost of parts and labor required to restore the product to proper operating condition. Transportation and
incidental costs associated with warranty repairs are not reimbursable under this warranty.
Warranty service is available only through authorized dealers and service centers.
This warranty does not cover defects resulting from misuse, abuse, negligence, accidents, lack of proper maintenance, normal wear,
alteration, modification, tampering, contaminated fuels, repair using improper parts, or repair by anyone other than an authorized dealer or
service center. Routine maintenance is the responsibility of the owner.
THIS EXPRESS WARRANTY IS GIVEN IN LIEU OF ANY OTHER WARRANTY EITHER EXPRESSED OR IMPLIED, INCLUDING
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
DESA International assumes no responsibility for indirect, incidental or consequential damages. Some states do not allow the exclusion or
limitation of incidental or consequential damages or limitations or exclusions may not apply to you. This Limited Warranty gives you specific
legal rights and you may also have other rights which vary from state to state.
WARRANTY SERVICE
Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater. The heater
will be inspected. A defect may be caused by faulty materials or workmanship. If so, DESA International will repair or replace the heater without charge.
REPAIR SERVICE
Return the heater to your nearest authorized service center. Each Service Center is independently owned and operated. Repairs not covered by the
warranty will be billed at standard prices. We reserve the right to amend these specifications at any time without notice.
Illustrated parts lists can be obtained free of charge. Send a self addressed stamped envelope to the address listed below. List the heater model number
and the date located in the lower right corner of this page. A service manual may be purchased from the address listed below. Send a check for $5.00
payable to DESA International. When writing for information regarding your heater, be sure to include the model number and serial number as shown
on the model plate.
For information about this warranty write:
2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004
104687 01
NOT A UPC
104687-01
Rev. D
11/98
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement