Desa CEF26-2 Fireplaces Owner manual

Desa CEF26-2 Fireplaces Owner manual
ELECTRIC FIREPLACE/INSERT MODEL CEF26-2
SAFETY INFORMATION AND INSTALLATION MANUAL
Read these instructions completely before beginning
installation. Failure to follow them could cause a heater
malfunction resulting in serious injury and/or property
damage.
WARNING: All electric heaters have hot and arcing or
sparking parts inside. Do not use it in areas where gasoline, paint or flammable liquids are or are stored.
WARNING: This heater is tested and listed for use only
with the optional accessories listed in these instructions. Use of optional accessories not specifically
tested for this heater could void the heater warranty
and/or result in a safety hazard.
This fireplace meets the construction and safety standards of H.U.D. for application in manufactured homes
when installed according to these instructions.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
For more information, visit www.desatech.com
Table of Contents
Safety Information................................................ 2
Listing Approvals.................................................. 3
Product Dimension Specifications........................ 3
Product Identification............................................ 3
Locating Fireplace................................................ 4
Unpacking and Testing Fireplace......................... 4
Installation............................................................ 5
Finishing............................................................... 7
Operating Instructions.......................................... 7
Cleaning and Maintenance................................... 8
Technical Service............................................... 10
Replacement Parts............................................. 10
AccessorY.......................................................... 10
Troubleshooting...................................................11
Illustrated Parts Breakdown and Parts List........ 12
Warranty Information............................Back Cover
Safety Information
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer
to this manual. For assistance or
additional information, consult
a qualified installer.
CAUTION: Do not expose the
heater to the elements (such as
rain, etc).
CAUTION: The fireplace insert
unit is mounted on rubber feet. The
purpose is to ensure adequate air
circulation beneath unit. DO NOT
remove these feet. Do not install
directly on carpet, rug, furniture
or similar surfaces which could
hinder or block the air flow.
Due to high temperatures, the
firebox should be located out of
traffic and away from furniture
and draperies.
Do not place clothing or other
flammable material on or near
firebox. Never place any objects
on the fireplace.
Carefully supervise young children when they are in the room
with fireplace.
Fireplace becomes very hot
when running. Keep children and
adults away from hot surfaces to
avoid burns or clothing ignition.
Fireplace will remain hot for a
time after shutdown. Allow surfaces to cool before touching.
When using electrical heaters, basic precautions
should always be followed to reduce the risk of
fire, electric shock and injury to persons, including
the following:
1. Read all instructions before using this heater.
2. Keep combustible materials, such as furniture,
pillows, bedding, papers, clothes and curtains
at least 3 feet from front of heater and keep
them away from sides and rear.
3. Always unplug heater when not in use.
4. Do not operate any heater with a damaged cord
or plug or after heater malfunctions, has been
dropped or damaged in any way. Return heater
to authorized service facility for examination,
electrical or mechanical adjustment or repair.
5. Do not use outdoors.
6. This heater is not intended for use in bathrooms, laundry areas and similar indoor
locations. Never locate heater where it may
fall into a bathtub or other water container.
7. Do not run cord under carpeting. Do not cover
cord with throw rugs, runners or the like. Arrange cord away from traffic area and where
it will not be tripped over.
8. To disconnect heater, turn controls to "OFF"
before removing plug from outlet.
9. Do not insert or allow foreign objects to enter any
ventilation or exhaust opening as this may cause
an electric shock or fire or damage the heater.
10. To prevent possible fire, do not block air
intakes in any manner.
11. A heater has hot and arcing or sparking parts
inside. Do not use it in areas where gasoline,
paint or flammable liquids or vapors are used
or stored.
www.desatech.com
120069-01A
21.26
21.125
Product Dimension
Specifications
4.33
SAFETY INFORMATION
Continued
13.25
12.0
22.75
26.125
21.26
21.125
4.33
12. Use this heater only as described in this
manual. Any other use not recommended
by the manufacturer may cause fire, electric
shock or injury to persons.
13. Avoid the use of an extension cord because
the extension cord may overheat and cause
a risk of fire. However, if you have to use an
extension cord, the cord should be No. 14
AWG minimum size and rated not less than
1875 WATTS.
14. Always use properly grounded fused and
polarized outlets.
15. Always use ground fault protection where
required by electrical codes.
16. Always disconnect power before performing
any cleaning, maintenance or relocation of
heater.
17. To prevent a possible fire, do not burn wood
or other materials in this heater.
18. To prevent electric shock or fire, always use
a certified electrician should new circuits or
outlets be required.
19. When transporting or storing heater, keep in
a dry place free from excessive vibration and
store as to avoid damage.
Figure13.25
1 - Heater Dimensions
12.0
Product
Identification
Flame Control
and Temp.
Buttons
ON/OFF
Power
Button
Listing Approvals
This heater has been tested in accordance with the
CSA Standards for fixed and location-dedicated
electric room heaters in the United States. All
components are UL or CSA safety certified.
If you need assistance during installation, please contact your local dealer or the DESA Heating Products
Technical Services Department at 1-866-672-6040.
Description:
Voltage:
Watts:
Amps:
Heat Vents
FL
26" Fireplace/Insert
120
1500
15 Amp
Grounded Circuit
Note: This heater must be electrically wired and
grounded in accordance with local codes or, in
the absence of local codes, with National Electric
Code ANSI/NFPA 70-latest edition or the Canadian Electric Code, CSA C2.1 as appropriate.
120069-01A
Fuse
Back
Glass
Front
Glass
Log
Figure 2 - Product Identification
www.desatech.com
Locating Fireplace
WARNING: Due to high temperatures, this heater should
be located out of traffic. Keep
combustible materials such
as furniture, pillows, bedding,
papers, clothes and curtains at
least 3 feet (0.9 m) from the front
of the heater.
WARNING: Never locate this
heater where it may fall into a bathtub or other water container.
NOTICE: Minimum and maximum
clearances must be maintained at
all times. Illustrations throughout
these instructions reflect typical
installations and are for design
purposes only. Actual installations may vary slightly due to
individual preferences.
WARNING: To prevent
contact with sagging or loose
insulation, the heater must not
be installed against vapor barrier
or exposed insulation. Localized
overheating could occur and a
fire could result.
CAUTION: Do not expose the
heater to the elements (such as
rain, etc.)
CAUTION: Wear gloves and
safety glasses for protection
during installation and maintenance.
Figure 3 illustrates a variety of ways the heater may
be located in a room. The heater may be installed
directly on the floor or raised on a hearth.
Figure 3 - Heater Locations
Unpacking and
Testing Fireplace
Carefully remove the unit from the box. Prior
to permanently installing the unit, test to make
sure the unit operates properly. To do this, plug
the unit's power supply cord into a conveniently
located 120-volt grounded outlet.
CAUTION; The unit's power
supply cord must be connected
to a properly grounded and protected 120-volt outlet. Always
use ground fault protection
where required by the electrical code.
WARNING: Do not operate
the unit if it is damaged or has
malfunctioned. If you suspect
the unit is damaged, return the
unit to an authorized service
facility for examination, electrical or mechanical adjustment
or repair.
www.desatech.com
120069-01A
Locating Fireplace
Continued
Framing
Figure 4 shows a typical framing of this heater using combustible materials. All required clearances
to combustibles must be adhered to. Header height
is measured from the base of the heater.
Tools and building supplies required for
installation:
• Saw
• Square
• Pliers
• Gloves
• Hammer
• Level
• Phillips screwdriver
• Framing materials
• Tape measure
• Surround
• Wall-finishing materials • Caulking material
• Electric drill/bits
27"
Header
Height
26 3/4"
CAUTION: Provide adequate
clearances around the air openings and adequate accessibility
clearances for servicing and
proper operations.
Installation
WARNING - RISK OF FIRE!
The power cord must not be
pinched or against a sharp edge.
Secure cord to avoid tripping or
snagging to reduce the risk of fire,
electric shock or personal injury.
Do not run cord under carpeting. Do not cover cord with
throw rugs, runners or the like.
Arrange cord away from traffic
areas and where it will not be
tripped over.
WARNING - RISK OF FIRE!
To prevent a possible fire, do
not block air intake or exhaust
in any manner. Do not use on
soft surfaces where openings
may become blocked.
WARNING - RISK OF FIRE!
Do not blow or place insulation
against the firebox.
13"
3/4" - 1/2"
WARNING: This heater is
tested and listed for use only
with the approved optional accessories. Use of optional accessories not specifically tested
for this heater could void the
heater warranty and/or result in
a safety hazard.
Note: The height
that a combustible
mantel is fitted
above the heater
is dependent on
the height of the
front selected. The
minimum height is
1" above the front.
Figure 4 - Framing Heater for New
Construction/Renovation
120069-01A
www.desatech.com
INSTALLATION
Continued
WARNING: If the information in these instructions is
not followed exactly, a fire or
explosion may result causing
property damage, personal injury or death.
Do not store or use gasoline or
other flammable vapors in the vicinity of this or any other heater.
Installing as a fireplace
Select a suitable location that is not susceptible to
moisture and is away from drapes, furniture and
high traffic areas. Note: Follow all national and
local electrical codes. This insert can be installed
into either an existing fireplace or as new construction/renovation.
Notice: Never pick unit up by
louvers. Louvers will bend.
Existing Fireplace Installation
1. Thoroughly clean out the existing fireplace
and hearth area.
2. Seal all drafts, vents or ash clean-outs with fiberglass insulation. Seal the flue. Once sealed, close
damper to stop debris from falling onto unit.
3. If existing fire box is susceptible to moisture, cap
the top of the chimney flue to prevent infiltration
of water. Note: It is strongly advised that you
hire a qualified professional to undertake this
step in order to prevent personal injury. Once the
flue is capped, the chimney is no longer suitable
for wood burning. Note: Do not install this unit
into a fireplace that is prone to dampness; the
area of installation must be dry.
4. Plan the power supply. If an existing grounded
outlet is near the fireplace, the power cord can
run along the front of the fireplace. If the cord is
not long enough to reach the outlet, a grounded
extension cord minimum AWG No. 14 and rated
to a minimum of 1875 watts, may be used. If you
plan to cut or drill a hole in the existing fireplace
for wiring, it is best to hire a professional to do
this step in order to prevent personal injury. To
reduce the risk of fire, do not run the power cord
under rugs, carpets, etc. Arrange the power supply cord away from high traffic areas where it
may pose a tripping hazard.
WARNING: The solid fuel/gas
fireplace has been converted for
use with an electric insert and
cannot be used for original fuels
unless all original parts have
been replaced and the fireplace
has been reapproved by the authority having jurisdiction.
New Construction or Renovation
1. Select a location that is not prone to moisture
and is located at least 0.9 m or 3 feet away
from combustible materials such as curtains
or drapes, furniture, bedding, paper, etc.
2. Place unit in selected location to see how it
will look in the future.
3. Mark the desired location on the floor and store
unit in a safe, dry and dust free location.
4. Frame in an opening leaving at least 1/4" (6 mm)
around the edge of the unit. Any new wiring
must be done in compliance with local and
national codes and other applicable regulations in order to reduce the risk of fire, electric
shock or other injuries. Therefore, it strongly
recommended that you hire a professional to
complete any such work.
5. Plan you power supply route. See step 4 of
Existing Fireplace Installation.
Installing Insert
Once the site has been prepared, the fireplace insert
can be installed.
1. Install trim onto front of unit.
2. Make sure switch is in the "OFF" position.
3. Plug fireplace into a 15-amp/120 volt,
grounded outlet.
4. Push fireplace insert so that the trim is against
the finished mantle or wall surface.
Notice: When the front is
installed it will cover the gap
between the heater and framing,
cabinet, finishing materials or
existing fireplace.
www.desatech.com
120069-01A
Finishing
Combustible Finishing Material: Materials
made of or surfaced with wood, compressed paper,
plant fibers, plastics or any material capable of
igniting and burning, whether flame proofed or not,
plastered or unplastered (this includes drywall).
Noncombustible Finishing Material : Materials which will not ignite and burn. Such materials
are those consisting entirely of steel, iron, brick,
tile, concrete, slate, glass or plasters or combinations thereof or have a fire rating of zero.
WARNING: Grills on this heater
cannot, in any way, be covered as
it may create a fire hazard.
Finishing checklist
• Power supply service must be completed prior
to finishing to avoid reconstruction.
• Grills and air openings cannot be covered in
any circumstances.
Note: The heater is a zero clearance fireplace and
may be finished with combustible or noncombustible finishing materials.
When using paint or lacquer to finish the mantel, they
must be heat resistant to prevent discoloration.
Operating
Instructions
The controls (see Figure 5) are located behind
the hinged top panel. Pull gently on top panel
to open.
Power
Flame Control
Receiver
ON/OFF
Power
Button
Operating by remote control
FL
Heater
Temperature
Figure 5 - Controls For Electric Fireplace
120069-01A
1. Plug in your electric fireplace.
2. Main ON/OFF Power Switch and LED:
This switch is located on the right side of
the control panel. The power LED will
light up when the unit is on (see Figure 5).
When unit is on, the default settings for the
fireplace is low background lighting and
high ember bed and flame and the heater
is off.
3. Temperature Control Button and LED:
This button is located to the right of the
Remote Control Receiver (see Figure 5). The
LED is located to the right of the Flame Button. Push button to cycle through settings.
When this button is pushed the LED will
come on. When heater is on heat will emit
through vents located in the middle of the
top louver panel (see Figure 2, page 3).
The heater has a built-in thermostat so
it will shut off automatically once the set
temperature is reached. It will also turn
on automatically if the room temperature
drops below the set temperature.
Note: When the heater is turned on for the
first time, it may release a slight, harmless
odor. This odor is a normal occurrence caused
by the initial heating of the internal heating
elements and should not occur again after
initial burn off. (This odor may occur again
if dust or debris has been trapped.)
4. Flame Control Button: This button is
located to the right of the Temperature
Button (see Figure 5). After power is on,
push the Flame Control Button to adjust
flame and ember bed brightness. Press and
release the Flame Control Button to cycle
through LO, MED, HI and OFF.
1. Plug in your electric fireplace.
2. Push the ON/OFF Power Button to turn
unit on. Power LED will light.
3. When operating the remote control, it must
be pointed at the sensor on the bottom
panel. Note: Make sure your batteries are
fully charged and installed correctly in your
remote control.
4. The ON/OFF button at the top left of the
remote is the main ON/OFF power button.
Pressing this button activates the power to
the unit.
5. To adjust the ember bed lighting and flame
brightness, press the "-" or "+" FLAME
buttons . There are four levels of brightness.
www.desatech.com
Operating
Instructions
Continued
6. The HEATER button activates the heater,
The heater is pre-set to the following
temperatures:
HI will shut off when room reaches approximately 86° F (30° C). The LED will be red.
MED will shut off when room reaches approximately 75° F (24° C). The LED will be
orange.
LO will shut off when room reaches approximately 64°F (18° C). The LED will be
green.
7. To adjust the light that shines on the logs
use the LAMP button. To increase or decrease, press the "-" or "+" buttons to cycle
through the four brightness settings.
8. To turn off the fireplace, press the ON/OFF
button once. When you restart the fireplace
with the remote control, all of the features
you had set will remain in effect.
NOTICE: This remote control must remain
within 8 meters or 26 feet of the fireplace to
be effective.
Infrared
Ray Exit
Indicator
Light
ON/OFF
-
+
LAMP
HEATER
-
FLAME
+
Cleaning and
Maintenance
WARNING: Always disconnect power and allow the heater
to cool before performing any
cleaning, maintenance or relocation of this heater. Turn controls
to OFF and remove plug from
outlet or turn off circuit breaker
to heater.
Turn off heater and circuit breaker to heater before
performing any cleaning and/or maintenance. Allow heater to cool completely.
Cleaning Firebox
Compartment
1. With gloves and safety glasses in place, remove
screw and bracket that holds front glass in
place.
2. Carefully remove front glass.
3. Using the brush vacuum attachment, gently
clean compartment.
4. After cleaning compartment, replace front
glass, screw and bracket. Reset circuit
breaker.
Back Glass
1. The glass is cleaned in the factory during
assembly. During shipment, installation, handling, etc. the glass surface may collect dust
particles. These can be removed by buffing
lightly with a clean dry cloth.
2. To remove fingerprints or other marks, the
glass can be cleaned with a damp cloth using
a good quality household glass cleaner. The
glass should be completely dried with a lint
free cloth or paper towel.
3. In the event of glass breakage, vacuum all
remaining glass pieces with a shop vac. DO
NOT VACUUM WHILE PIECES ARE HOT.
Replace glass only with replacement part
specifically for this heater. Never substitute
material. Only fully tempered soda lime safety
glass may be used on this heater.
Figure 6 - Remote Control For Electric
Fireplace
www.desatech.com
120069-01A
Cleaning and
Maintenance
Continued
Bulb Replacement
WARNING: The halogen light
bulbs in your unit can become
extremely hot. Allow at least 10
minutes between turning off the
heater and removing the light
bulbs to avoid accidental burns.
There are a total of 8 halogen light bulbs (type
GX6.35 rated 120 volts, 35 watts) in your unit.
• 2 bulbs provide illumination for the ember bed
beneath the log set
• 2 bulbs provide illumination for the flame
generation assembly
• 2 bulbs for backlighting
• 2 bulbs for replacement
WARNING: Do not install
replacement bulbs that exceed
specified maximum watts.
Flame Generation Bulbs
1. Carefully remove front glass (see steps 1
and 2 under Cleaning Firebox Compartment, page 8).
2. From the bottom, gently pull forward and lift
up log set ember bed until front edge clears
the front of the unit (do not pull up on logs).
3. Remove left and right screws and brackets
that hold glass in place. These are located at
the bottom of glass panel (see Figure 8).
4. With gloves and safety glasses in place, lift up on
bottom of glass by placing the bracket removed
in step 3 under the edge of the glass. Gently push
upward and pull forward. Place glass on smooth,
soft surface to avoid breakage.
5. Locate flame generation cylindrical drum,
Figure 9.
6. Squeeze half of drum cylinder until it's top
edge clears the top drum track. Remove bottom edge of cylinder drum from bottom drum
track. This will give you access to the light
bulbs. Note: Do not exert excessive pressure
on drum cylinder as this may cause damage.
Glass
Your fireplace unit must be opened in order to
replace the light bulbs. To reduce the number of
times you need to open the unit, replace all bulbs
at the same time.
Ember Bed Bulbs
1. Carefully remove front glass (see steps 1
and 2 under Cleaning Firebox Compartment, page 8).
2. From the bottom, gently pull forward and lift
up log set ember bed until front edge clears
the front of the unit (do not pull up on logs).
3. Remove spring clip. Hold socket and pull out
the old bulb.
4. Hold socket and push in new bulb (DO NOT
exceed wattage).
5. Replace spring clip onto bulb.
6. Repeat steps 3 through 5 for second bulb.
7. Gently push ember bed down until rear edge
is resting against rear ledge of unit.
8. Replace front glass.
Spring Clip
Glass
Bracket
Figure 8 - Glass and Bracket Location
Flame Cylinder Drum
Figure 9 - Flame Generation Cylinder
Drum
Bulbs
Figure 7 - Ember Bed Bulb Location
120069-01A
www.desatech.com
Cleaning and
Maintenance
Continued
7. Remove spring clip. Hold socket and pull out
old bulb.
8. Hold socket and push in new bulb (DO NOT
exceed wattage). Replace spring clip.
9. Repeat steps 5 and 6 on page 9 for second
bulb.
10. Insert bottom edge of removed cylinder half
into bottom drum track. Squeeze drum cylinder until it's top edge fits into top drum rack.
11. With gloves, carefully replace glass. Slide top
of glass into metal slot and slide bottom onto
ledge.
12. Place brackets against glass and tighten
screws.
13. Gently push ember bed down until rear edge
is resting against rear ledge of unit.
14. Replace front glass.
Backlighting Bulbs
1. Remove front glass.
2. Remove spring clips. Note: Bulbs located on
underside of top. Hold socket and pull out old
bulb.
3. Hold socket and push in new bulb.
4. Replace spring clip on bulb
5. Replace front glass.
Technical Service
You may have further questions about installation,
operation or troubleshooting. If so, contact DESA
Heating Products’ Technical Service Department
at 1-866-672-6040. When calling please have your
model and serial numbers of your heater ready.
You can also visit DESA Heating Products’ technical services web site at www.desatech.com.
10
Replacement Parts
Note: Use only original replacement parts. This
will protect your warranty coverage for parts
replaced under warranty.
Parts Under Warranty
Contact authorized dealers of this product. If
they can’t supply original replacement part(s),
call DESA Heating Products’ Technical Service
Department at 1-866-672-6040.
When calling DESA Heating Products, have
ready
• your name
• your address
• model and serial numbers of your heater
• how heater was malfunctioning
• purchase date
Usually, we will ask you to return the part to the
factory.
Parts Not Under Warranty
Contact authorized dealers of this product. If they
can’t supply original replacement part(s), call
DESA Heating Products at 1-866-672-6040 for
referral information.
When calling DESA Heating Products, have
ready
• model number of your heater
• the replacement part number
AccessorY
Fireplace Front Trim
bnft - Brushed Nickel
BFT - Black
www.desatech.com
120069-01A
Troubleshooting
WARNING: Turn off appliance and let cool before servicing. Only
a qualified service person should service and repair heater.
OBSERVED PROBLEM
POSSIBLE CAUSE
REMEDY
Fireplace turns off and will not
turn on
1. Fireplace has overheated
and safety devise has cause
thermal switch to disconnect
or home circuit breaker has
opened
1. Reset switch by turning main
power switch off and waiting
5 minutes then turning it back
on or reset circuit breaker
Flame is not moving
1. Loose wiring
1. Inspect wiring for loose connections
2. Call a qualified service technician to replace flame motor
2. Flame motor defective
Dim or poorly visible flame
1. Bulb(s) are burnt out
2. Wiring is loose
1. Inspect bulbs and replace if
necessary
2. Disconnect from power source
and inspect wiring for loose
connections and repair or
replace if necessary
Log set and/or ember is not
glowing
1. Bulb(s) are burnt out
1. Inspect bulbs and replace if
necessary
Flame sputters
1. Flame motor is defective
1. Call a qualified service technician to replace flame motor
Remote control does not work
1. Low batteries
1. Replace AA batteries in remote control
Fireplace will not come on when
switch is flipped to ON
1. Fireplace is not plugged in to
an electrical outlet
2. Fuse has blown
1. Check plug
Heater does not provide heat
when turned on
1. Thermal switch has been
tripped
1. Turn unit off and unplug
unit for 5 minutes. Plug back
in and turn unit on. If plug
cannot be reached, follow
directions for tripped circuit
breaker
2. Turn off circuit breaker that
supplies electricity to unit.
Wait 5 minutes then flip circuit
breaker back on
2. Circuit breaker has been
tripped
120069-01A
www.desatech.com
2. Disconnect from power source
and replace fuse (see Figure 2,
page 3) with F3.15A fuse
11
Illustrated Parts Breakdown
Model CEF26-2
13
9
8
5
12
14
1
2
6
7
3
11
10
10
4
12
10
11
12
11
10
9
12
www.desatech.com
120069-01A
PARTS LIST
Model CEF26-2
This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions
listed under Replacement Parts on page 10 of this manual.
KEY
NO.
PART NO.
DESCRIPTION
1
2
3
4
5
6
7
8
9
117748-01
119612-01
117697-01
117749-01
119614-01
117745-01
117742-01
119613-01
119616-01
10
11
12
13
14
117754-01
117695-01
117743-01
117753-01
120077-01
Blower and Heater Assembly
Control Board (26" Electric)
Flame Motor
Flame Cylinder Assembly
Log
Rear Glass (Mirror)
Front Glass
ON/OFF Touch Pad
Hardware Kit: Feet, Screws,
Board Clips
Light Bulb Sockets
Bulb
Screw and Clip (Glass Retainer)
Louver
ON/OFF Switch
QTY.
1
1
1
1
1
1
1
1
1
4
6
3
1
1
PARTS AVAILABLE — NOT SHOWN
117711-01
111401-01
120069-01A
Remote Control
Batteries (AA)
www.desatech.com
1
2
13
NOTES
_____________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
_____________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
_____________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
14
www.desatech.com
120069-01A
NOTES
_____________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
_____________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
_____________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
120069-01A
www.desatech.com
15
Warranty Information
KEEP THIS WARRANTY
Model
Serial No.
Date Purchased
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our
standard written warranty. We make no other warranty, expressed or implied.
LIMITED WARRANTY
ELECTRIC FIREPLACE/INSERT
DESA Heating Products warrants this product to be free from defects in materials and components for one (1) year
from the date of first purchase (excluding bulbs and fuses), provided that the product has been properly installed,
operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the
Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required
to restore this heater to proper operating condition (excluding bulbs and fuses) and an allowance for labor when
provided by a DESA Heating Products Authorized Service Center. Warranty part(s) MUST be obtained through
authorized dealers of this product and/or DESA Heating Products who will provide original factory replacement
parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a
qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that
fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper
installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a
defective heater will be the responsibility of the owner. Replacement bulbs are not included in this warranty.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE
OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED
WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO ONE (1)
YEAR ON ALL COMPONENTS (EXCLUDING BULBS) FROM THE DATE OF FIRST PURCHASE; AND
DESA Heating Products’ LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE
PRODUCT AND DESA Heating Products SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES
WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of
incidental or consequential damages, so the above limitation on implied warranties or exclusion or limitation on
damages may not apply to you.
This warranty gives you specific legal rights and you may also have other rights that vary from state to state.
For information about this warranty write:
2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004
www.desatech.com
120069 01
NOT A UPC
120069-01
Rev. A
08/06
Was this manual useful for you? yes no