1.
Safety Symbol Definitions
DANGER! − Indicates a hazardous situation which, if not
avoided, will result in death or serious injury. The possible hazards are shown in the adjoining symbols or
explained in the text.
DANGER ! - Indique une situation dangereuse qui, si
elle n’est pas évitée, entraînera la mort ou des blessures
graves. Les éventuels risques sont représentés par les
symboles joints ou expliqués dans le texte.
Wear safety glasses with side shields.
Porter des lunettes de sécurité avec écrans latéraux.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury. The possible hazards are shown in the adjoining symbols or explained in
the text.
Indique une situation dangereuse qui, si elle n’est pas
évitée, entraînera la mort ou des blessures graves. Les
éventuels risques sont représentés par les symboles
joints ou expliqués dans le texte.
Have only trained and qualified persons install, operate,
or service this unit. Call your distributor if you do not
understand the directions. For WELDING SAFETY and
EMF information, read owner’s manual(s).
Ne confiez l’installation, l’exploitation ou l’entretien de cet
appareil qu’à des personnes compétentes et qualifiées.
Lire les directives de sécurité au début de ces
instructions et dans chaque section. Appeler votre
distributeur si vous ne comprenez pas les directives.
Lire le(s) manuel(s) d’utilisateur pour des
renseignements sur la SÉCURITÉ DE SOUDAGE et les
champs électromagnétiques.
Indicates statements not related to personal injury.
Signale des consignes non associées aux dommages
corporels.
Indicates special instructions.
Fournit des instructions spéciales.
Static electricity can damage parts on circuit boards. Put
on grounded wrist strap before touching board.
L’électricité statique peut endommager les composants
des cartes électroniques. S’équiper d’un bracelet
anti-statique, mise à la terre, avant de manipuler la carte
électronique.
Fsafe8 2013-10
Fsafe1 2013-10
Fsafe2 2013-10
Fsafe15 2013-10
NOTICE
Fsafe3 2013-10
Fsafe21 2013-10
Beware of electric shock from wiring. Disconnect input
power before installing this kit. Reinstall all panels and
covers.
Attention aux décharges électriques au contact des
câbles. Couper l’alimentation électrique avant d’installer
ce kit. Réinstaller tous les panneaux et couvercles.
Fsafe7 2013-10
CALIFORNIA PROPOSITION 65 WARNINGS
PROPOSITION CALIFORIENNE 65 AVERTISSEMENTS
Welding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause birth defects and, in some cases, cancer. (California Health & Safety Code Section 25249.5 et seq.)
This product contains chemicals, including lead, known to the state of California to cause cancer, birth defects, or other reproductive
harm. Wash hands after use.
Les équipements de soudage et de coupage produisent des fumées et des gaz qui contiennent des produits chimiques dont l’État de
Californie reconnaît qu’ils provoquent des malformations congénitales et, dans certains cas, des cancers. (Code de santé et de
sécurité de Californie, chapitre 25249.5 et suivants)
Ce produit contient des produits chimiques, notamment du plomb, dont l’État de Californie reconnaît qu’ils provoquent des cancers,
des malformations congénitales ou d’autres problèmes de procréation. Se laver les mains après utilisation.
Fsafe4 2013-10
2.
Specifications
Description: Analog Interface
Input Power: 24 Volts DC, 0.5 Amps
H
Dimensions (L x W x H): 10.43 x 5 x 7.28 in. (265 x 127 x 185 mm)
L
W
Weight: 6.1 lb (2.7 kg)
277970-A
 2016 MILLER Electric Mfg. Co.
3.
Tools Needed
5/16 in.
4.
Connecting Analog Interface To Welding Power Source
2
!
Turn off welding power source,
and disconnect input power.
1
2
3
Welding Power Source
DeviceNet Receptacle
Analog Interface DeviceNet Plug
Use the supplied cord to connect the
analog interface DeviceNet plug to
the welding power source DeviceNet
receptacle.
1
4
Analog Interface 72 Pin
Receptacle
Connect analog interface 72 pin receptacle to robot interface 72 pin plug.
5
4
Prevent internal nut
from turning when
tightening screw.
3
6
6
Analog Interface Mounting
Screws
Analog Interface Mounting Holes
(On Back Of Box)
If desired, analog interface can be
mounted on welding power source.
Loosen mounting screws on welding
power source. Align holes in interface
bracket with mounting screws. Tighten screws.
Troubleshooting Information
7
5
S
7
S
S
Analog Interface Viewing
Window
If both LEDs are solid green, the
analog interface is connected and
communicating with the welding
power source.
If both LEDs are flashing green,
the analog interface communications are trying to connect to the
welding power source.
If both LEDs are red, no communications are established between the analog interface and
welding power source.
Contact a Factory Authorized Service
Agent to resolve any problems.
Reconnect input power. Turn on welding power source.
277970-A / 277971-A
5.
Enabling Analog Functionality
1
1
User Interface
Use interface screen to enable analog feature.
On interface screen, click System.
Scroll through menu and select Robot Optional.
Scroll and select Communication
Method.
Scroll and select Analog.
Click Home to return to main interface screen.
907 657-tp2
OM-277585 Page 2
6.
Enabling Auto Calibration
1
1
User Interface
Use interface screen to enable auto
calibration feature.
On interface screen, click Setup.
Scroll through Setup menu and select
Auto Calibration.
Select Yes to run Auto Calibration.
The user interface will indicate Auto
Calibration is running. Allow robot to
run through low and high commands.
(Commands are shown on interface
screen.)
The interface screen will indicate the
test is complete. The system then returns to normal operation.
907 657-tp2
OM-277585 Page 3
7.
Electrical Diagram
277586-A
Figure 7-1. Circuit Diagram
OM-277585 Page 4
8.
Parts List
4
2
7
9
10
3
5
1
8
6
277970-A
Figure 8-1. Complete Assembly
Item
No.
Dia.
Mkgs.
Part
No.
Quantity
Description
Figure 8-1. Complete Assembly
. . . 1 . . . . . . . . . . . . . . 224012 . . .
. . . 2 . . . . . . . . . . . . . . 277915 . . .
. . . 3 . . . . . . . . . . . . . . 277913 . . .
. . . 4 . . . . . . . . . . . . . . 277914 . . .
. . . 5 . . . . . . . . . . . . . . 201058 . . .
. . . . . . . . . . . . . . . . . . . . 604464 . . .
. . . 6 . . . . . . . . . . . . . . 239388 . . .
. . . 7 . . . . . . . . . . . . . . 256085 . . .
. . . . . . . . . . . . . . . . . . . . 221285 . . .
. . . . . . . . . . . . . . . . . . . . 277572 . . .
. . . 8 . . . . . . . . . . . . . . 254679 . . .
. . . . . . . . . . . . . . . . . . . . 254625 . . .
. . . . . . . . . . . . . . . . . . . . 277992 . . .
. . . 9 . . . . PC26 . . . . 276883 . . .
. . . 10 . . . . PC27 . . . . 239627 . . .
. . . . . . . . . . . . . . . . . . . 221285 . . .
. . . . . . . . . . . . . . . . . . . 221284 . . .
Plate, Rotation Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bracket, Mtg Auto−Continuum Analog Interface . . . . . . . . . . . . . . . . . . . . . .
Panel, Front Auto−Continuum Analog Interface . . . . . . . . . . . . . . . . . . . . . .
Panel, Rear Auto−Continuum Analog Interface . . . . . . . . . . . . . . . . . . . . . . .
Conn, Rect 72 Pin Assy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Term, Frict 250x032 Uninsul Feml 18−14ga 170od . . . . . . . . . . . . . . . . . . .
Bumper, Rbr .875 Od X .188 Id X .406 High Recessed . . . . . . . . . . . . . . . .
Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable, Extension 9 Ft 5pin DeviceNet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Plugs, W/Leads (Touch Sense Continuum Analog) . . . . . . . . . . . . . . . . . . .
Receptacle Assy, DeviceNet w/Leads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable Assy, Access Test Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Plug, Jumper Auto−Continuum Analog Adapter E−Stop . . . . . . . . . . . . . . .
Circuit Card Assy, Continuum Interface Mod w/Prgrm . . . . . . . . . . . . . . . .
Circuit Card Assy, Robot Interface Filter Hf . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable, Extension 9 Ft 5 Pin DeviceNet . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable, Extension 20 Ft 5 Pin DeviceNet . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
1
1
1
3
1
1
1
1
1
1
1
1
1
1
OPTIONAL
BE SURE TO PROVIDE MODEL AND SERIAL NUMBER WHEN ORDERING REPLACEMENT PARTS.