Miller AXCESS E WIRE FEEDER User manual

Miller AXCESS E WIRE FEEDER User manual
OM-245 592A
2010−01
Processes
MIG (GMAW) Welding
Description
Wire Feeder
R
Axcess E Wire Feeder
Visit our website at
www.MillerWelds.com/ams
File: Advanced Manufacturing Systems
From Miller to You
Thank you and congratulations on choosing Miller. Now you can get
the job done and get it done right. We know you don’t have time to do
it any other way.
That’s why when Niels Miller first started building arc welders in 1929,
he made sure his products offered long-lasting value and superior
quality. Like you, his customers couldn’t afford anything less. Miller
products had to be more than the best they could be. They had to be the
best you could buy.
Today, the people that build and sell Miller products continue the
tradition. They’re just as committed to providing equipment and service
that meets the high standards of quality and value established in 1929.
This Owner’s Manual is designed to help you get the most out of your
Miller products. Please take time to read the Safety precautions. They
will help you protect yourself against potential hazards on the worksite.
We’ve made installation and operation quick
and easy. With Miller you can count on years
of reliable service with proper maintenance.
And if for some reason the unit needs repair,
there’s a Troubleshooting section that will
help you figure out what the problem is. The
Miller is the first welding parts list will then help you to decide the
equipment manufacturer in exact part you may need to fix the problem.
the U.S.A. to be registered to
the ISO 9001:2000 Quality Warranty and service information for your
System Standard.
particular model are also provided.
Miller Electric manufactures a full line
of welders and welding related equipment.
For information on other quality Miller
products, contact your local Miller distributor to receive the latest full
line catalog or individual specification sheets. To locate your nearest
distributor or service agency call 1-800-4-A-Miller, or visit us at
www.MillerWelds.com on the web.
Mil_Thank 2009−09
Working as hard as you do
− every power source from
Miller is backed by the most
hassle-free warranty in the
business.
TABLE OF CONTENTS
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4. California Proposition 65 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-6. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1. Symboles utilisés . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2. Dangers relatifs au soudage à l’arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance . . . . . .
2-4. Proposition californienne 65 Avertissements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-5. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-6. Informations relatives aux CEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 − INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2. Serial Number And Rating Label Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 4 − INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-1. Selecting A Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. Connection Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3. Rear Panel Connections And Rotating Drive Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-4. 9-Pin Network Receptacle Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-5. Installing And Threading Welding Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-6. Feeder Display At Power Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-7. Dual Schedule Switch Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 5 − OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-1. Operational Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2. Power Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-3. Front Panel Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-4. Program Push Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-5. Upper Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-6. Lower Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-7. Feeder Set Up Push Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-8. Adjust Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-9. Process Set Up Push Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-10. Jog/Purge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-11. User Interface Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 − SETTING SEQUENCE PARAMETERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-1. Sequence Parameters In A Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 7 − MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-2. Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-3. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 8 − ELECTRICAL DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 9 − PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARRANTY
1
1
1
3
4
4
4
5
5
5
7
8
9
9
11
11
11
11
11
12
13
14
15
16
17
18
18
19
20
21
21
22
23
24
24
25
26
33
33
34
34
35
37
38
40
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING
som _2009−08
7
Protect yourself and others from injury — read and follow these precautions.
1-1. Symbol Usage
DANGER! − Indicates a hazardous situation which, if
not avoided, will result in death or serious injury. The
possible hazards are shown in the adjoining symbols
or explained in the text.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury. The possible
hazards are shown in the adjoining symbols or explained in the text.
NOTICE − Indicates statements not related to personal injury.
. Indicates special instructions.
This group of symbols means Warning! Watch Out! ELECTRIC
SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult symbols and related instructions below for necessary actions to avoid the
hazards.
1-2. Arc Welding Hazards
The symbols shown below are used throughout this manual
to call attention to and identify possible hazards. When you
see the symbol, watch out, and follow the related instructions
to avoid the hazard. The safety information given below is
only a summary of the more complete safety information
found in the Safety Standards listed in Section 1-5. Read and
follow all Safety Standards.
Only qualified persons should install, operate, maintain, and
repair this unit.
During operation, keep everybody, especially children, away.
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shocks
or severe burns. The electrode and work circuit is
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also
live when power is on. In semiautomatic or automatic
wire welding, the wire, wire reel, drive roll housing,
and all metal parts touching the welding wire are
electrically live. Incorrectly installed or improperly
grounded equipment is a hazard.
D Do not touch live electrical parts.
D Wear dry, hole-free insulating gloves and body protection.
D Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.
D Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
D Use AC output ONLY if required for the welding process.
D If AC output is required, use remote output control if present on
unit.
D Additional safety precautions are required when any of the following electrically hazardous conditions are present: in damp
locations or while wearing wet clothing; on metal structures such
as floors, gratings, or scaffolds; when in cramped positions such
as sitting, kneeling, or lying; or when there is a high risk of unavoidable or accidental contact with the workpiece or ground. For these
conditions, use the following equipment in order presented: 1) a
semiautomatic DC constant voltage (wire) welder, 2) a DC manual
(stick) welder, or 3) an AC welder with reduced open-circuit voltage. In most situations, use of a DC, constant voltage wire welder
is recommended. And, do not work alone!
D Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
D Properly install and ground this equipment according to its
Owner’s Manual and national, state, and local codes.
D Always verify the supply ground − check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
grounded receptacle outlet.
D When making input connections, attach proper grounding conductor first − double-check connections.
D Keep cords dry, free of oil and grease, and protected from hot metal
and sparks.
D Frequently inspect input power cord for damage or bare wiring −
replace cord immediately if damaged − bare wiring can kill.
D Turn off all equipment when not in use.
D Do not use worn, damaged, undersized, or poorly spliced cables.
D Do not drape cables over your body.
D If earth grounding of the workpiece is required, ground it directly
with a separate cable.
D Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
D Do not touch electrode holders connected to two welding machines at the same time since double open-circuit voltage will be
present.
D Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
D Wear a safety harness if working above floor level.
D Keep all panels and covers securely in place.
D Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
D Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
D Do not connect more than one electrode or work cable to any
single weld output terminal.
SIGNIFICANT DC VOLTAGE exists in inverter welding power sources AFTER removal of inputpower.
D Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section
before touching any parts.
HOT PARTS can burn.
D Do not touch hot parts bare handed.
D Allow cooling period before working on equipment.
D To handle hot parts, use proper tools and/or
wear heavy, insulated welding gloves and
clothing to prevent burns.
OM-245 592 Page 1
FUMES AND GASES can be hazardous.
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health.
D Keep your head out of the fumes. Do not breathe the fumes.
D If inside, ventilate the area and/or use local forced ventilation at the
arc to remove welding fumes and gases.
D If ventilation is poor, wear an approved air-supplied respirator.
D Read and understand the Material Safety Data Sheets (MSDSs)
and the manufacturer’s instructions for metals, consumables,
coatings, cleaners, and degreasers.
D Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watchperson nearby. Welding fumes and gases can displace air and
lower the oxygen level causing injury or death. Be sure the breathing air is safe.
D Do not weld in locations near degreasing, cleaning, or spraying operations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.
D Do not weld on coated metals, such as galvanized, lead, or
cadmium plated steel, unless the coating is removed from the weld
area, the area is well ventilated, and while wearing an air-supplied
respirator. The coatings and any metals containing these elements
can give off toxic fumes if welded.
D Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
D Wear oil-free protective garments such as leather gloves, heavy
shirt, cuffless trousers, high shoes, and a cap.
D Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.
D After completion of work, inspect area to ensure it is free of sparks,
glowing embers, and flames.
D Use only correct fuses or circuit breakers. Do not oversize or bypass them.
D Follow requirements in OSHA 1910.252 (a) (2) (iv) and NFPA 51B
for hot work and have a fire watcher and extinguisher nearby.
FLYING METAL or DIRT can injure eyes.
D Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool,
they can throw off slag.
D Wear approved safety glasses with side
shields even under your welding helmet.
BUILDUP OF GAS can injure or kill.
D Shut off shielding gas supply when not in use.
D Always ventilate confined spaces or use
approved air-supplied respirator.
ARC RAYS can burn eyes and skin.
Arc rays from the welding process produce intense
visible and invisible (ultraviolet and infrared) rays
that can burn eyes and skin. Sparks fly off from the
weld.
D Wear an approved welding helmet fitted with a proper shade of
filter lenses to protect your face and eyes from arc rays and
sparks when welding or watching (see ANSI Z49.1 and Z87.1
listed in Safety Standards).
D Wear approved safety glasses with side shields under your
helmet.
D Use protective screens or barriers to protect others from flash,
glare and sparks; warn others not to watch the arc.
D Wear protective clothing made from durable, flame-resistant
material (leather, heavy cotton, or wool) and foot protection.
WELDING can cause fire or explosion.
Welding on closed containers, such as tanks,
drums, or pipes, can cause them to blow up. Sparks
can fly off from the welding arc. The flying sparks, hot
workpiece, and hot equipment can cause fires and
burns. Accidental contact of electrode to metal objects can cause
sparks, explosion, overheating, or fire. Check and be sure the area is
safe before doing any welding.
D Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
D Do not weld where flying sparks can strike flammable material.
D Protect yourself and others from flying sparks and hot metal.
D Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
D Watch for fire, and keep a fire extinguisher nearby.
D Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
D Do not weld on closed containers such as tanks, drums, or pipes,
unless they are properly prepared according to AWS F4.1 (see
Safety Standards).
D Do not weld where the atmosphere may contain flammable dust,
gas, or liquid vapors (such as gasoline).
D Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly
unknown paths and causing electric shock, sparks, and fire
hazards.
D Do not use welder to thaw frozen pipes.
OM-245 592 Page 2
ELECTRIC AND MAGNETIC FIELDS (EMF)
can affect ImplantedMedical Devices.
D Wearers of Pacemakers and other Implanted
Medical Devices should keep away.
D Implanted Medical Device wearers should consult their doctor
and the device manufacturer before going near arc welding, spot
welding, gouging, plasma arc cutting, or induction heating
operations.
NOISE can damage hearing.
Noise from some processes or equipment can
damage hearing.
D Wear approved ear protection if noise level is
high.
CYLINDERS can explode if damaged.
Shielding gas cylinders contain gas under high
pressure. If damaged, a cylinder can explode. Since
gas cylinders are normally part of the welding
process, be sure to treat them carefully.
D Protect compressed gas cylinders from excessive heat, mechanical shocks, physical damage, slag, open flames, sparks, and arcs.
D Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
D Keep cylinders away from any welding or other electrical circuits.
D Never drape a welding torch over a gas cylinder.
D Never allow a welding electrode to touch any cylinder.
D Never weld on a pressurized cylinder − explosion will result.
D Use only correct shielding gas cylinders, regulators, hoses, and fittings designed for the specific application; maintain them and
associated parts in good condition.
D Turn face away from valve outlet when opening cylinder valve.
D Keep protective cap in place over valve except when cylinder is in
use or connected for use.
D Use the right equipment, correct procedures, and sufficient number of persons to lift and move cylinders.
D Read and follow instructions on compressed gas cylinders,
associated equipment, and Compressed Gas Association (CGA)
publication P-1 listed in Safety Standards.
1-3. Additional Symbols For Installation, Operation, And Maintenance
FIRE OR EXPLOSION hazard.
D Do not install or place unit on, over, or near
combustible surfaces.
D Do not install unit near flammables.
D Do not overload building wiring − be sure power supply system is
properly sized, rated, and protected to handle this unit.
FALLING EQUIPMENT can injure.
D Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
D Use equipment of adequate capacity to lift and
support unit.
D If using lift forks to move unit, be sure forks are long enough to
extend beyond opposite side of unit.
D Keep equipment (cables and cords) away from moving vehicles
when working from an aerial location.
D Follow the guidelines in the Applications Manual for the Revised
NIOSH Lifting Equation (Publication No. 94−110) when manually lifting heavy parts or equipment.
MOVING PARTS can injure.
D Keep away from moving parts such as fans.
D Keep all doors, panels, covers, and guards
closed and securely in place.
D Have only qualified persons remove doors, panels, covers, or
guards for maintenance and troubleshooting as necessary.
D Reinstall doors, panels, covers, or guards when maintenance is
finished and before reconnecting input power.
READ INSTRUCTIONS.
D Read and follow all labels and the Owner’s
Manual carefully before installing, operating, or
servicing unit. Read the safety information at
the beginning of the manual and in each
section.
D Use only genuine replacement parts from the manufacturer.
D Perform maintenance and service according to the Owner’s
Manuals, industry standards, and national, state, and local
codes.
OVERUSE can cause OVERHEATING
H.F. RADIATION can cause interference.
D Allow cooling period; follow rated duty cycle.
D Reduce current or reduce duty cycle before
starting to weld again.
D Do not block or filter airflow to unit.
FLYING SPARKS can injure.
D Wear a face shield to protect eyes and face.
D Shape tungsten electrode only on grinder with
proper guards in a safe location wearing proper
face, hand, and body protection.
D Sparks can cause fires — keep flammables away.
D
D
D
D
STATIC (ESD) can damage PC boards.
D Put on grounded wrist strap BEFORE handling
boards or parts.
D Use proper static-proof bags and boxes to
store, move, or ship PC boards.
ARC WELDING can cause interference.
MOVING PARTS can injure.
D Keep away from moving parts.
D Keep away from pinch points such as drive
rolls.
WELDING WIRE can injure.
D Do not press gun trigger until instructed to do
so.
D Do not point gun toward any part of the body,
other people, or any metal when threading
welding wire.
D High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communications equipment.
D Have only qualified persons familiar with
electronic equipment perform this installation.
The user is responsible for having a qualified electrician promptly correct any interference problem resulting from the installation.
If notified by the FCC about interference, stop using the
equipment at once.
Have the installation regularly checked and maintained.
Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.
D
D
D
D
D Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.
D Be sure all equipment in the welding area is
electromagnetically compatible.
To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
Locate welding operation 100 meters from any sensitive electronic equipment.
Be sure this welding machine is installed and grounded
according to this manual.
If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables,
using line filters, or shielding the work area.
OM-245 592 Page 3
1-4. California Proposition 65 Warnings
Welding or cutting equipment produces fumes or gases
which contain chemicals known to the State of California to
cause birth defects and, in some cases, cancer. (California
Health & Safety Code Section 25249.5 et seq.)
Battery posts, terminals and related accessories contain lead
and lead compounds, chemicals known to the State of
California to cause cancer and birth defects or other
reproductive harm. Wash hands after handling.
For Gasoline Engines:
Engine exhaust contains chemicals known to the State of
California to cause cancer, birth defects, or other reproductive harm.
For Diesel Engines:
Diesel engine exhaust and some of its constituents are
known to the State of California to cause cancer, birth
defects, and other reproductive harm.
1-5. Principal Safety Standards
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
from Global Engineering Documents (phone: 1-877-413-5184, website:
www.global.ihs.com).
Safe Practices for the Preparation of Containers and Piping for Welding
and Cutting, American Welding Society Standard AWS F4.1, from Global Engineering Documents (phone: 1-877-413-5184, website:
www.global.ihs.com).
National Electrical Code, NFPA Standard 70, from National Fire Protection Association, Quincy, MA 02269 (phone: 1-800-344-3555, website:
www.nfpa.org and www. sparky.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 4221 Walney Road, 5th Floor,
Chantilly, VA 20151 (phone: 703-788-2700, website:www.cganet.com).
Safety in Welding, Cutting, and Allied Processes, CSA Standard
W117.2, from Canadian Standards Association, Standards Sales, 5060
Spectrum Way, Suite 100, Ontario, Canada L4W 5NS (phone:
800-463-6727, website: www.csa-international.org).
Safe Practice For Occupational And Educational Eye And Face Protection, ANSI Standard Z87.1, from American National Standards Institute,
25 West 43rd Street, New York, NY 10036 (phone: 212-642-4900, website: www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, from National Fire Protection Association,
Quincy, MA 02269 (phone: 1-800-344-3555, website: www.nfpa.org.
OSHA, Occupational Safety and Health Standards for General Industry, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,
and Part 1926, Subpart J, from U.S. Government Printing Office, Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954
(phone: 1-866-512-1800) (there are 10 OSHA Regional Offices—
phone for Region 5, Chicago, is 312-353-2220, website:
www.osha.gov).
U.S. Consumer Product Safety Commission (CPSC), 4330 East West
Highway, Bethesda, MD 20814 (phone: 301-504-7923, website:
www.cpsc.gov).
Applications Manual for the Revised NIOSH Lifting Equation, The National Institute for Occupational Safety and Health (NIOSH), 1600
Clifton Rd, Atlanta, GA 30333 (phone: 1-800-232-4636, website:
www.cdc.gov/NIOSH).
1-6. EMF Information
Electric current flowing through any conductor causes localized electric
and magnetic fields (EMF). Welding current creates an EMF field
around the welding circuit and welding equipment. EMF fields may interfere with some medical implants, e.g. pacemakers. Protective
measures for persons wearing medical implants have to be taken. For
example, access restrictions for passers−by or individual risk assessment for welders. All welders should use the following procedures in
order to minimize exposure to EMF fields from the welding circuit:
1. Keep cables close together by twisting or taping them, or using a
cable cover.
2. Do not place your body between welding cables. Arrange cables
to one side and away from the operator.
3. Do not coil or drape cables around your body.
OM-245 592 Page 4
4. Keep head and trunk as far away from the equipment in the
welding circuit as possible.
5. Connect work clamp to workpiece as close to the weld as
possible.
6. Do not work next to, sit or lean on the welding power source.
7. Do not weld whilst carrying the welding power source or wire
feeder.
About Implanted Medical Devices:
Implanted Medical Device wearers should consult their doctor and the
device manufacturer before performing or going near arc welding, spot
welding, gouging, plasma arc cutting, or induction heating operations.
If cleared by your doctor, then following the above procedures is recommended.
SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION
fre_som_2009−08
7
Se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes.
2-1. Symboles utilisés
DANGER! − Indique une situation dangereuse qui si on
l’évite pas peut donner la mort ou des blessures graves.
Les dangers possibles sont montrés par les symboles
joints ou sont expliqués dans le texte.
Indique une situation dangereuse qui si on l’évite pas
peut donner la mort ou des blessures graves. Les dangers possibles sont montrés par les symboles joints ou
sont expliqués dans le texte.
NOTE − Indique des déclarations pas en relation avec des blessures
personnelles.
. Indique des instructions spécifiques.
Ce groupe de symboles veut dire Avertissement! Attention! DANGER
DE CHOC ELECTRIQUE, PIECES EN MOUVEMENT, et PIECES
CHAUDES. Consulter les symboles et les instructions ci-dessous y
afférant pour les actions nécessaires afin d’éviter le danger.
2-2. Dangers relatifs au soudage à l’arc
Les symboles représentés ci-dessous sont utilisés dans ce manuel pour attirer l’attention et identifier les dangers possibles. En
présence de l’un de ces symboles, prendre garde et suivre les
instructions afférentes pour éviter tout risque. Les instructions
en matière de sécurité indiquées ci-dessous ne constituent
qu’un sommaire des instructions de sécurité plus complètes
fournies dans les normes de sécurité énumérées dans la Section 2-5. Lire et observer toutes les normes de sécurité.
Seul un personnel qualifié est autorisé à installer, faire fonctionner, entretenir et réparer cet appareil.
Pendant le fonctionnement, maintenir à distance toutes les
personnes, notamment les enfants de l’appareil.
UNE DÉCHARGE ÉLECTRIQUE peut
entraîner la mort.
Le contact d’organes électriques sous tension peut
provoquer des accidents mortels ou des brûlures
graves. Le circuit de l’électrode et de la pièce est
sous tension lorsque le courant est délivré à la
sortie. Le circuit d’alimentation et les circuits internes de la machine sont également sous tension
lorsque l’alimentation est sur Marche. Dans le mode
de soudage avec du fil, le fil, le dérouleur, le bloc de
commande du rouleau et toutes les parties métalliques en contact avec le fil sont sous tension
électrique. Un équipement installé ou mis à la terre
de manière incorrecte ou impropre constitue un
danger.
D Ne pas toucher aux pièces électriques sous tension.
D Porter des gants isolants et des vêtements de protection secs et
sans trous.
D S’isoler de la pièce à couper et du sol en utilisant des housses ou
des tapis assez grands afin d’éviter tout contact physique avec la
pièce à couper ou le sol.
D Ne pas se servir de source électrique à courant électrique dans les
zones humides, dans les endroits confinés ou là où on risque de
tomber.
D Se servir d’une source électrique à courant électrique UNIQUEMENT si le procédé de soudage le demande.
D Si l’utilisation d’une source électrique à courant électrique s’avère
nécessaire, se servir de la fonction de télécommande si l’appareil
en est équipé.
D D’autres consignes de sécurité sont nécessaires dans les conditions suivantes : risques électriques dans un environnement
humide ou si l’on porte des vêtements mouillés ; sur des structures
métalliques telles que sols, grilles ou échafaudages ; en position
coincée comme assise, à genoux ou couchée ; ou s’il y a un risque
élevé de contact inévitable ou accidentel avec la pièce à souder ou
le sol. Dans ces conditions, utiliser les équipements suivants,
dans l’ordre indiqué : 1) un poste à souder DC à tension constante
(à fil), 2) un poste à souder DC manuel (électrode) ou 3) un poste à
souder AC à tension à vide réduite. Dans la plupart des situations,
l’utilisation d’un poste à souder DC à fil à tension constante est recommandée. En outre, ne pas travailler seul !
D Couper l’alimentation ou arrêter le moteur avant de procéder à l’installation, à la réparation ou à l’entretien de l’appareil. Déverrouiller
l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de sécurité).
D Installer le poste correctement et le mettre à la terre convenablement selon les consignes du manuel de l’opérateur et les normes
nationales, provinciales et locales.
D Toujours vérifier la terre du cordon d’alimentation. Vérifier et
s’assurer que le fil de terre du cordon d’alimentation est bien
raccordé à la borne de terre du sectionneur ou que la fiche du
cordon est raccordée à une prise correctement mise à la terre.
D En effectuant les raccordements d’entrée, fixer d’abord le conducteur de mise à la terre approprié et contre-vérifier les connexions.
D Les câbles doivent être exempts d’humidité, d’huile et de graisse;
protégez−les contre les étincelles et les pièces métalliques
chaudes.
D Vérifier fréquemment le cordon d’alimentation afin de s’assurer
qu’il n’est pas altéré ou à nu, le remplacer immédiatement s’il l’est.
Un fil à nu peut entraîner la mort.
D L’équipement doit être hors tension lorsqu’il n’est pas utilisé.
D Ne pas utiliser des câbles usés, endommagés, de grosseur insuffisante ou mal épissés.
D Ne pas enrouler les câbles autour du corps.
D Si la pièce soudée doit être mise à la terre, le faire directement
avec un câble distinct.
D Ne pas toucher l’électrode quand on est en contact avec la pièce,
la terre ou une électrode provenant d’une autre machine.
D Ne pas toucher des porte électrodes connectés à deux machines
en même temps à cause de la présence d’une tension à vide doublée.
D N’utiliser qu’un matériel en bon état. Réparer ou remplacer sur-lechamp les pièces endommagées. Entretenir l’appareil conformément à ce manuel.
D Porter un harnais de sécurité si l’on doit travailler au-dessus du sol.
D S’assurer que tous les panneaux et couvercles sont correctement
en place.
D Fixer le câble de retour de façon à obtenir un bon contact métalmétal avec la pièce à souder ou la table de travail, le plus près possible de la soudure.
D Isoler la pince de masse quand pas mis à la pièce pour éviter le
contact avec tout objet métallique.
D Ne pas raccorder plus d’une électrode ou plus d’un câble de
masse à une même borne de sortie de soudage.
OM-245 592 Page 5
Il reste une TENSION DC NON NÉGLIGEABLE dans
les sources de soudage onduleur UNE FOIS
l’alimentation coupée.
D Arrêter les convertisseurs, débrancher le courant électrique et
décharger les condensateurs d’alimentation selon les instructions
indiquées dans la partie Entretien avant de toucher les pièces.
LES PIÈCES CHAUDES peuvent
provoquer des brûlures.
D Ne pas toucher à mains nues les parties
chaudes.
D Prévoir une période de refroidissement avant de
travailler à l’équipement.
D Ne pas toucher aux pièces chaudes, utiliser les outils recommandés et porter des gants de soudage et des vêtements épais pour
éviter les brûlures.
LE SOUDAGE peut provoquer un
incendie ou une explosion.
Le soudage effectué sur des conteneurs fermés tels
que des réservoirs, tambours ou des conduites peut
provoquer leur éclatement. Des étincelles peuvent
être projetées de l’arc de soudure. La projection d’étincelles, des
pièces chaudes et des équipements chauds peut provoquer des
incendies et des brûlures. Le contact accidentel de l’électrode avec
des objets métalliques peut provoquer des étincelles, une explosion,
un surchauffement ou un incendie. Avant de commencer le soudage,
vérifier et s’assurer que l’endroit ne présente pas de danger.
D Déplacer toutes les substances inflammables à une distance de
10,7 m de l’arc de soudage. En cas d’impossibilité les recouvrir
soigneusement avec des protections homologués.
D Ne pas souder dans un endroit là où des étincelles peuvent tomber
sur des substances inflammables.
LES FUMÉES ET LES GAZ peuvent
être dangereux.
D Se protéger et d’autres personnes de la projection d’étincelles et
de métal chaud.
Le soudage génère des fumées et des gaz. Leur
inhalation peut être dangereux pour votre santé.
D Des étincelles et des matériaux chauds du soudage peuvent
facilement passer dans d’autres zones en traversant de petites
fissures et des ouvertures.
D Eloigner votre tête des fumées. Ne pas respirer les fumées.
D Surveiller tout déclenchement d’incendie et tenir un extincteur à
proximité.
D À l’intérieur, ventiler la zone et/ou utiliser une ventilation forcée au
niveau de l’arc pour l’évacuation des fumées et des gaz de
soudage.
D Le soudage effectué sur un plafond, plancher, paroi ou séparation
peut déclencher un incendie de l’autre côté.
D Si la ventilation est médiocre, porter un respirateur anti-vapeurs
approuvé.
D Lire et comprendre les spécifications de sécurité des matériaux
(MSDS) et les instructions du fabricant concernant les métaux, les
consommables, les revêtements, les nettoyants et les dégraisseurs.
D Travailler dans un espace fermé seulement s’il est bien ventilé ou
en portant un respirateur à alimentation d’air. Demander toujours à
un surveillant dûment formé de se tenir à proximité. Des fumées et
des gaz de soudage peuvent déplacer l’air et abaisser le niveau
d’oxygène provoquant des blessures ou des accidents mortels.
S’assurer que l’air de respiration ne présente aucun danger.
D Ne pas souder dans des endroits situés à proximité d’opérations
de dégraissage, de nettoyage ou de pulvérisation. La chaleur et
les rayons de l’arc peuvent réagir en présence de vapeurs et former des gaz hautement toxiques et irritants.
D Ne pas souder des métaux munis d’un revêtement, tels que l’acier
galvanisé, plaqué en plomb ou au cadmium à moins que le revêtement n’ait été enlevé dans la zone de soudure, que l’endroit soit
bien ventilé, et en portant un respirateur à alimentation d’air. Les
revêtements et tous les métaux renfermant ces éléments peuvent
dégager des fumées toxiques en cas de soudage.
LES RAYONS DE L’ARC peuvent
provoquer des brûlures dans les
yeux et sur la peau.
Le rayonnement de l’arc du procédé de soudage
génère des rayons visibles et invisibles intense
(ultraviolets et infrarouges) susceptibles de provoquer des brûlure
dans les yeux et sur la peau. Des étincelles sont projetées pendant le
soudage.
D Porter un casque de soudage approuvé muni de verres filtrants
approprié pour protéger visage et yeux pour protéger votre visage
et vos yeux pendant le soudage ou pour regarder (voir ANSI Z49.1
et Z87.1 énuméré dans les normes de sécurité).
D Porter des lunettes de sécurité avec écrans latéraux même sous
votre casque.
D Avoir recours à des écrans protecteurs ou à des rideaux pour
protéger les autres contre les rayonnements les éblouissements
et les étincelles ; prévenir toute personne sur les lieux de ne pas
regarder l’arc.
D Porter des vêtements confectionnés avec des matières résistantes et ignifuges (cuir, coton lourd ou laine) et des bottes de
protection.
OM-245 592 Page 6
D Ne pas effectuer le soudage sur des conteneurs fermés tels que
des réservoirs, tambours, ou conduites, à moins qu’ils n’aient été
préparés correctement conformément à AWS F4.1 (voir les normes de sécurité).
D Ne soudez pas si l’air ambiant est chargé de particules, gaz, ou vapeurs inflammables (vapeur d’essence, par exemple).
D Brancher le câble de masse sur la pièce le plus près possible de la
zone de soudage pour éviter le transport du courant sur une
longue distance par des chemins inconnus éventuels en provoquant des risques d’électrocution, d’étincelles et d’incendie.
D Ne pas utiliser le poste de soudage pour dégeler des conduites gelées.
D En cas de non utilisation, enlever la baguette d’électrode du porteélectrode ou couper le fil à la pointe de contact.
D Porter des vêtements de protection dépourvus d’huile tels que des
gants en cuir, une chemise en matériau lourd, des pantalons sans
revers, des chaussures hautes et un couvre chef.
D Avant de souder, retirer toute substance combustible de vos poches telles qu’un allumeur au butane ou des allumettes.
D Une fois le travail achevé, assurez−vous qu’il ne reste aucune
trace d’étincelles incandescentes ni de flammes.
D Utiliser exclusivement des fusibles ou coupe−circuits appropriés.
Ne pas augmenter leur puissance; ne pas les ponter.
D Une fois le travail achevé, assurez−vous qu’il ne reste aucune
trace d’étincelles incandescentes ni de flammes.
D Utiliser exclusivement des fusibles ou coupe−circuits appropriés.
Ne pas augmenter leur puissance; ne pas les ponter.
D Suivre les recommandations dans OSHA 1910.252(a)(2)(iv) et
NFPA 51B pour les travaux à chaud et avoir de la surveillance et un
extincteur à proximité.
DES PIECES DE METAL ou DES
SALETES peuvent provoquer des
blessures dans les yeux.
D Le soudage, l’écaillement, le passage de la pièce à la brosse en
fil de fer, et le meulage génèrent des étincelles et des particules
métalliques volantes. Pendant la période de refroidissement des
soudures, elles risquent de projeter du laitier.
D Porter des lunettes de sécurité avec écrans latéraux ou un écran
facial.
LES ACCUMULATIONS DE GAZ
risquent de provoquer des blessures
ou même la mort.
D Fermer l’alimentation du gaz protecteur en cas
de non-utilisation.
D Veiller toujours à bien aérer les espaces confinés ou se servir d’un respirateur d’adduction
d’air homologué.
Les CHAMPS ÉLECTROMAGNÉTIQUES (CEM)
peuvent affecter les implants médicaux.
D Les porteurs de stimulateurs cardiaques
et autres implants médicaux doivent rester
à distance.
D Les porteurs d’implants médicaux doivent consulter
leur médecin et le fabricant du dispositif avant de s’approcher
de la zone où se déroule du soudage à l’arc, du soudage
par points, du gougeage, de la découpe plasma
ou une opération de chauffage par induction.
LES BOUTEILLES peuvent exploser
si elles sont endommagées.
Des bouteilles de gaz protecteur contiennent du gaz
sous haute pression. Si une bouteille est endommagée, elle peut exploser. Du fait que les bouteilles
de gaz font normalement partie du procédé de
soudage, les manipuler avec précaution.
D Protéger les bouteilles de gaz comprimé d’une chaleur excessive,
des chocs mécaniques, des dommages physiques, du laitier, des
flammes ouvertes, des étincelles et des arcs.
D Placer les bouteilles debout en les fixant dans un support stationnaire ou dans un porte-bouteilles pour les empêcher de tomber ou
de se renverser.
D Tenir les bouteilles éloignées des circuits de soudage ou autres
circuits électriques.
D Ne jamais placer une torche de soudage sur une bouteille à gaz.
D Une électrode de soudage ne doit jamais entrer en contact avec
une bouteille.
D Ne jamais souder une bouteille pressurisée − risque d’explosion.
D Utiliser seulement des bouteilles de gaz protecteur, régulateurs,
tuyaux et raccords convenables pour cette application spécifique ;
les maintenir ainsi que les éléments associés en bon état.
D Détourner votre visage du détendeur-régulateur lorsque vous
ouvrez la soupape de la bouteille.
LE BRUIT peut endommager l’ouïe.
Le bruit des processus et des équipements peut
affecter l’ouïe.
D Porter des protections approuvées pour les
oreilles si le niveau sonore est trop élevé.
D Le couvercle du détendeur doit toujours être en place, sauf lorsque
la bouteille est utilisée ou qu’elle est reliée pour usage ultérieur.
D Utiliser les équipements corrects, les bonnes procédures et suffisamment de personnes pour soulever et déplacer les bouteilles.
D Lire et suivre les instructions sur les bouteilles de gaz comprimé,
l’équipement connexe et le dépliant P-1 de la CGA (Compressed
Gas Association) mentionné dans les principales normes de sécurité.
2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance
Risque D’INCENDIE OU
D’EXPLOSION.
D Ne pas placer l’appareil sur, au-dessus ou
à proximité de surfaces inflammables.
D Ne pas installer l’appareil à proximité de produits inflammables.
D Ne pas surcharger l’installation électrique − s’assurer que
l’alimentation est correctement dimensionnée et protégée avant
de mettre l’appareil en service.
LA CHUTE DE L’ÉQUIPEMENT peut
provoquer des blessures.
D Utiliser l’anneau de levage uniquement pour
soulever l’appareil, NON PAS les chariots, les
bouteilles de gaz ou tout autre accessoire.
D Utiliser un équipement de levage de capacité
suffisante pour lever l’appareil.
D En utilisant des fourches de levage pour déplacer l’unité, s’assurer que les fourches sont suffisamment longues pour dépasser
du côté opposé de l’appareil.
D Tenir l’équipement (câbles et cordons) à distance des véhicules
mobiles lors de toute opération en hauteur.
D Suivre les consignes du Manuel des applications pour l’équation
de levage NIOSH révisée (Publication Nº94–110) lors du levage
manuelle de pièces ou équipements lourds.
L’EMPLOI
EXCESSIF
peut
SURCHAUFFER L’ÉQUIPEMENT.
D Prévoir une période de refroidissement ; respecter le cycle opératoire nominal.
D Réduire le courant ou le facteur de marche
avant de poursuivre le soudage.
D Ne pas obstruer les passages d’air du poste.
LES ÉTINCELLES PROJETÉES
peuvent provoquer des blessures.
D Porter un écran facial pour protéger le visage et
les yeux.
D Affûter l’électrode au tungstène uniquement à la
meuleuse dotée de protecteurs. Cette
manœuvre est à exécuter dans un endroit sûr
lorsque l’on porte l’équipement homologué de
protection du visage, des mains et du corps.
D Les étincelles risquent de causer un incendie − éloigner toute substance inflammable.
LES CHARGES ÉLECTROSTATIQUES peuvent endommager les circuits imprimés.
D Établir la connexion avec la barrette de terre
avant de manipuler des cartes ou des pièces.
D Utiliser des pochettes et des boîtes antistatiques pour stocker, déplacer ou expédier des
cartes de circuits imprimes.
OM-245 592 Page 7
Les PIÈCES MOBILES peuvent
causer des blessures.
LE
RAYONNEMENT
HAUTE
FRÉQUENCE
(H.F.)
risque
de
provoquer des interférences.
D Ne pas s’approcher des organes mobiles.
D Ne pas s’approcher des points de coincement
tels que des rouleaux de commande.
LES FILS DE SOUDAGE peuvent
provoquer des blessures.
D Ne pas appuyer sur la gâchette avant d’en
avoir reçu l’instruction.
D Ne pas diriger le pistolet vers soi, d’autres
personnes ou toute pièce mécanique en
engageant le fil de soudage.
Les PIÈCES MOBILES peuvent
causer des blessures.
D S’abstenir de toucher des organes mobiles tels
que des ventilateurs.
D Maintenir fermés et verrouillés les portes,
panneaux, recouvrements et dispositifs de
protection.
D Lorsque cela est nécessaire pour des travaux d’entretien et de
dépannage, faire retirer les portes, panneaux, recouvrements
ou dispositifs de protection uniquement par du personnel qualifié.
D Remettre les portes, panneaux, recouvrements ou dispositifs de
protection quand l’entretien est terminé et avant de rebrancher
l’alimentation électrique.
LIRE LES INSTRUCTIONS.
D Lire et appliquer les instructions sur les
étiquettes et le Mode d’emploi avant l’installation, l’utilisation ou l’entretien de l’appareil.
Lire les informations de sécurité au début du
manuel et dans chaque section.
D N’utiliser que les pièces de rechange recommandées par le
constructeur.
D Effectuer l’entretien en respectant les manuels d’utilisation, les
normes industrielles et les codes nationaux, d’état et locaux.
D Le rayonnement haute fréquence (H.F.) peut
provoquer des interférences avec les équipements de radio−navigation et de communication, les services de sécurité et les ordinateurs.
D Demander seulement à des personnes qualifiées familiarisées
avec des équipements électroniques de faire fonctionner l’installation.
D L’utilisateur est tenu de faire corriger rapidement par un électricien
qualifié les interférences résultant de l’installation.
D Si le FCC signale des interférences, arrêter immédiatement l’appareil.
D Effectuer régulièrement le contrôle et l’entretien de l’installation.
D Maintenir soigneusement fermés les portes et les panneaux des
sources de haute fréquence, maintenir les éclateurs à une distance correcte et utiliser une terre et un blindage pour réduire les
interférences éventuelles.
LE SOUDAGE À L’ARC risque de
provoquer des interférences.
D
D
D
D
D
D L’énergie électromagnétique risque de
provoquer des interférences pour l’équipement
électronique sensible tel que les ordinateurs et
l’équipement commandé par ordinateur tel que
les robots.
Veiller à ce que tout l’équipement de la zone de soudage soit
compatible électromagnétiquement.
Pour réduire la possibilité d’interférence, maintenir les câbles de
soudage aussi courts que possible, les grouper, et les poser
aussi bas que possible (ex. par terre).
Veiller à souder à une distance de 100 mètres de tout équipement électronique sensible.
Veiller à ce que ce poste de soudage soit posé et mis à la terre
conformément à ce mode d’emploi.
En cas d’interférences après avoir pris les mesures précédentes, il incombe à l’utilisateur de prendre des mesures supplémentaires telles que le déplacement du poste, l’utilisation de câbles blindés, l’utilisation de filtres de ligne ou la pose de protecteurs dans la zone de travail.
2-4. Proposition californienne 65 Avertissements
Les équipements de soudage et de coupage produisent des
fumées et des gaz qui contiennent des produits chimiques
dont l’État de Californie reconnaît qu’ils provoquent des malformations congénitales et, dans certains cas, des cancers.
(Code de santé et de sécurité de Californie, chapitre 25249.5
et suivants)
Les batteries, les bornes et autres accessoires contiennent
du plomb et des composés à base de plomb, produits chimiques dont l’État de Californie reconnaît qu’ils provoquent des
cancers et des malformations congénitales ou autres
problèmes de procréation. Se laver les mains après manipulation.
OM-245 592 Page 8
Pour les moteurs à essence :
Les gaz d’échappement des moteurs contiennent des produits chimiques dont l’État de Californie reconnaît qu’ils
provoquent des cancers et des malformations congénitales
ou autres problèmes de procréation.
Pour les moteurs diesel :
Les gaz d’échappement des moteurs diesel et certains de
leurs composants sont reconnus par l’État de Californie comme provoquant des cancers et des malformations
congénitales ou autres problèmes de procréation.
2-5. Principales normes de sécurité
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
de Global Engineering Documents (téléphone : 1-877-413-5184, site
Internet : www.global.ihs.com).
Safe Practices for the Preparation of Containers and Piping for Welding
and Cutting, American Welding Society Standard AWS F4.1, de Global
Engineering Documents (téléphone : 1-877-413-5184, site internet :
www.global.ihs.com).
National Electrical Code, NFPA Standard 70, de National Fire Protection Association, Quincy, MA 02269 (téléphone : 800-344-3555, site
Internet : www.nfpa.org et www.sparky.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
de Compressed Gas Association, 4221 Walney Road, 5th Floor, Chantilly, VA 20151 (téléphone : 703-788-2700, site Internet :
www.cganet.com).
Safety in Welding, Cutting, and Allied Processes, CSA Standard
W117.2, de Canadian Standards Association, Standards Sales, 5060
Spectrum Way, Suite 100, Ontario, Canada L4W 5NS (téléphone :
800-463-6727, site internet : www.csa-international.org).
Safe Practice For Occupational And Educational Eye And Face Protection, ANSI Standard Z87.1, de American National Standards Institute,
25 West 43rd Street, New York, NY 10036 (téléphone : 212-642-4900,
site Internet : www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, de National Fire Protection Association,
P.O. Box 9101, Quincy, MA 02269-9101 (téléphone : 617-770-3000,
site Internet : www.nfpa.org).
OSHA, Occupational Safety and Health Standards for General
Industry, Title 29, Code of Federal Regulations (CFR), Part 1910,
Subpart Q, and Part 1926, Subpart J, de U.S. Government Printing
Office, Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA
15250-7954 (téléphone : 1-866-512-1800) (il y a 10 bureaux
régionaux−le téléphone de la région 5, Chicago, est 312-353-2220, site
Internet : www.osha.gov).
U.S. Consumer Product Safety Commission (CPSC), 4330 East West
Highway, Bethesda, MD 20814 (téléphone : 301-504-7923, site internet : www.cpsc.gov).
Applications Manual for the Revised NIOSH Lifting Equation, The
National Institute for Occupational Safety and Health (NIOSH), 1600
Clifton Rd, Atlanta, GA 30333 (télé[hone : 1-800-232-4636, site internet:
www.cdc.gov/NIOSH).
2-6. Informations relatives aux CEM
Le courant électrique qui traverse tout conducteur génère des champs
électromagnétiques (CEM) à certains endroits. Le courant de soudage
crée un CEM autour du circuit et du matériel de soudage. Les CEM
peuvent créer des interférences avec certains implants médicaux
comme des stimulateurs cardiaques. Des mesures de protection pour
les porteurs d’implants médicaux doivent être prises: par exemple, des
restrictions d’accès pour les passants ou une évaluation individuelle
des risques pour les soudeurs. Tous les soudeurs doivent appliquer les
procédures suivantes pour minimiser l’exposition aux CEM provenant
du circuit de soudage:
4. Maintenir la tête et le torse aussi loin que possible du matériel du
circuit de soudage.
1. Rassembler les câbles en les torsadant ou en les attachant avec
du ruban adhésif ou avec une housse.
2. Ne pas se tenir au milieu des câbles de soudage. Disposer les
câbles d’un côté et à distance de l’opérateur.
3. Ne pas courber et ne pas entourer les câbles autour de votre
corps.
En ce qui concerne les implants médicaux :
5. Connecter la pince sur la pièce aussi près que possible de la
soudure.
6. Ne pas travailler à proximité d’une source de soudage, ni
s’asseoir ou se pencher dessus.
7. Ne pas souder tout en portant la source de soudage ou le
dévidoir.
Les porteurs d’implants doivent d’abord consulter leur médecin avant
de s’approcher des opérations de soudage à l’arc, de soudage par
points, de gougeage, du coupage plasma ou de chauffage par induction. Si le médecin approuve, il est recommandé de suivre les
procédures précédentes.
OM-245 592 Page 9
OM-245 592 Page 10
SECTION 3 − INTRODUCTION
3-1. Specifications
Type of Input
Power
Welding Power
Source Type
40 Volts DC
10 Amperes
Axcess E Series
Wire Feed Speed Range
Wire Diameter
Range
Welding Circuit
Rating
Overall
Dimensions
Weight
Standard: 40 To 1400 ipm (1.0
To 35.6 mpm)
.030 To 1/8 in.
(0.8 To 3.2 mm)
100 Volts,
750 Amperes,
100% Duty
Cycle
Length: 27 in. (686
mm)
46 lb
(20.9 kg)
Max Spool
Weight: 60 lb (27
kg)
Width: 12-1/2 in.
(318 mm)
Height: 14-1/2 in.
(368 mm)
3-2. Serial Number And Rating Label Location
The serial number and rating information for this product is located on the back. Use rating label to determine input power requirements and/or rated
output. For future reference, write serial number in space provided on back cover of this manual.
SECTION 4 − INSTALLATION
4-1. Selecting A Location
Movement
Tipping
!
Do not move or operate
unit where it could tip.
2
OR
1
Location
!
Special installation may be required where gasoline or volatile
liquids are present − see NEC Article 511 or CEC Section 20.
!
Do not stack units. Beware of
tipping.
1
Lifting Forks
Use lifting forks to move unit.
3
Extend forks beyond opposite side
of unit.
2
Hand Cart
Use cart or similar device to move
unit.
3
18 in.
(460 mm)
Line Disconnect Device
Locate unit near correct input
power supply.
18 in.
(460 mm)
loc_2 3/96 - Ref. 245 867-A
OM-245 592 Page 11
4-2. Connection Diagram
3
4
5
2
1
1
2
3
4
5
6
7
8
Welding Power Source
Wire Feeder
Gas Cylinder
Gas Hose
Network Feeder Cable
Negative (−) Weld Cable
Workpiece
Voltage Sensing Lead
Recommended for Accu-pulse.
. Positive
(+) voltage sensing
lead is contained in the motor
cable.
7
9
8
Positive (+) Weld Cable
9
6
245 739-A
OM-245 592 Page 12
4-3. Rear Panel Connections And Rotating Drive Assembly
1
2
9-Pin Network Receptacle
Shielding Gas Valve Fitting
Requires fitting with 5/8-18
right-hand threads. Connect
customer supplied gas hose.
3
4
5
6
7
Weld Cable Terminal
Weld Cable
Drive Assembly
Drive Assembly Rotation
Knob
Rating Label Location
To rotate the drive assembly,
loosen drive assembly rotation
knob, rotate drive assembly, and
tighten knob.
7
1
2
3
4
5
6
Tools Needed:
9/16, 5/8 in.
3/16 in.
802 825-A / 803 503-A
OM-245 592 Page 13
4-4. 9-Pin Network Receptacle Information
9
F
E
G
H
I
D
C
A
B
OM-245 592 Page 14
Pin
Pin Information
A
Capacitor C1 to ground
B
Shield
C
Volt sense
D
Can low
E
Can high
F
+24 volts DC common
G
+ 24 volts DC
H
Motor voltage −40 volts
I
Motor voltage +40 volts
4-5. Installing And Threading Welding Wire
Install wire guides and
anti-wear guide.
Install wire spool. Adjust tension nut so
wire is taut when wire feed stops.
Install drive rolls.
Pressure
Adjust
Rear
Rolls
Pressure
Indicator
Scale
Pressure
Adjust
Front
Rolls
No Wire Slip
Wire Slips
NONCONDUCTIVE
SURFACE
NONCONDUCTIVE
SURFACE
Drive Rolls
Tools Needed:
3/16, 5/64 in.
Gun Cable
15/16, 3/8 in.
End Of Liner
. Be sure that outlet cable has proper size . For soft wire or small diameter stainless . To adjust drive roll pressure, hold nozzle
liner for the welding wire size. When
installing
gun,
position
liner
extending from outlet wire guide as
close as possible to drive rolls without
touching.
Install gun. Lay gun cable out straight. Cut off
end of wire. Push wire through guides up to
drive rolls; continue to hold wire. Press Jog
button to feed wire out gun.
steel wire, reduce drive roll pressure on
the rear roll to half that of the front rolls.
This unit is equipped with Auto Thread
capability. By rocking the switch from purge to
jog within 0.5 seconds will automatically feed
wire for a factory default setting of 192 in
(4877 mm) of wire before stopping. The
default feed rate is 700 ipm. These settings
can be changed using the HTML pages.
about 2 in (51 mm) from nonconductive
surface and press gun trigger to feed wire
against surface. Tighten knob so wire
does not slip. Do not overtighten. If
contact tip is completely blocked, wire
should slip at the feeder (see pressure
adjustment above).Cut wire off. Close
cover.
Ref. 156 929-A / Ref. 150 922 / Ref. 156 930 / 802 954 / S-0627-A
OM-245 592 Page 15
4-6.
Feeder Display At Power Up
1
Program
Volts
Time
WFS
Amps
1
2
While the system is initializing, the
display will alternate between “Net
Wait” and counting up dashes
before the power source is fully
operational.
Arc Adjust
Arc Ctl
Process
Sequence
Wire Type
Gas Type
Trigger Hold
Power Source
2
Trigger Control
Process Set Up
Adjust
Upper Display
Feeder Set Up
Lower Display
Net
Wait
Net
Wait
Voltage Range
—
— —
Net
Wait
— — —
Net
Wait
— — — —
Net
— — — —
Net
— — — —
Net
— — — —
Net
— — — —
Axcess E
OM-245 592 Page 16
Upper Display
Lower Display
Wait
—
Wait
— —
Wait
— — —
Wait
— — — —
Net
Wait
DTEC
OFF
Axcs
300/450/675
10
44
4-7. Dual Schedule Switch Option
1
Maint 2P (Maintained-Contact
2-Pole Switch)
DSS-9M Part# 041 793
1
DSS-9M 1
2
2
A
3
B
4
1
OM-245 592 Page 17
SECTION 5 − OPERATION
5-1. Operational Terms
The following is a list of terms and their definitions as they apply to the interface unit in the wire feeder:
General Terms:
Arc Adjust
Term used to represent arc length adjustments in pulse programs. Increasing Arc Adjust increases
the actual arc length. Likewise, decreasing arc adjust shortens arc length. Arc Adjust is replaced by
volts in MIG programs.
Trigger Control
Selecting Trigger Control allows activating trigger functions such as DS, TH, 4T, TDS, and TPS.
DS (Dual Schedule)
Dual Schedule allows selecting a pair of programs that can be used together.
TH (Trigger Hold)
Trigger Hold allows the operator to feed wire without continuously pressing the gun trigger. In trigger
hold mode, momentarily press gun trigger, and wire will feed until gun trigger is momentarily pressed
again.
4T
4T allows the operator to select between weld parameters and crater parameters using the gun
trigger. Crater time must be set for at least 0.2 seconds to make this function operational. If gun
trigger is released during welding, unit goes into trigger hold, then pressing and holding trigger again
causes unit to stay in crater until trigger is released and crater parameter times out.
TDS (Trigger Dual Schedule)
TDS allows the operator to select between a pair of weld programs by using the gun trigger. In TDS
mode, momentarily release and close the gun trigger while welding to cycle between a pair of
preselected weld programs.
TPS (Trigger Program Schedule)
TPS allows the operator to select weld programs by using the gun trigger. In TPS mode, momentarily
pressing the gun trigger allows the operator to cycle through preselected weld programs up to a total
of 8 programs.
Program
Eight active slots for selection of various processes, wire type, and parameters.
Process
A selection made for MIG, Pulse, and Accu-pulse.
MIG
CV weld process with individual settings of voltage and wire speed.
Pulse
Conventional pulse program using peak, background, pulse width, frequency, and peak voltage as
factory taught data. Adaptive method is controlled by frequency adjustment.
Accu-pulse
Pulse process utilizing constant current ramps with constant voltage control of peaks and
backgrounds. Adaptive response is controlled by peak and minimum current levels. Benefits are
shorter arc lengths, better puddle control, more tolerant of tip-to-work variation, less audible noise, no
arc wandering, allows weld to fill in at toes increasing travel speed and deposition, and more tolerant
to poor fit up and gaps.
AccuCurve
CV Pulse process using a pulse waveform with modified curves at particular locations within
the waveform. Has a distinguished change in arc characteristics. Front panel display is
ACCU − CURV.
Wire Type
Selection of wire type by alloys and classification.
Gas Type
Selection of shielding gas being used in application.
Process Set Up
Selection procedure for entering program.
Program Load
Enters selected program information into program slot.
Volts
Preset voltage in MIG mode at idle, actual voltage while welding, and 3 seconds hold value at end of
weld.
Time
Indicates time values being set for timed functions (e.g. Preflow, Postflow which are only available in
the Arc On and Analog input or the Arc On and No Analog input modes).
Arc Length
Distance from end of wire electrode to workpiece.
WFS
Term used to represent wire feed speed. In MIG mode, wire feed setting is independent of voltage
setting. In pulse and Accu-pulse adjusting wire feed speed also increases power level on wire electrode (one knob control).
Amps
Indicates average amperage while welding and 3 seconds hold value at end of weld.
Arc Control
Allows setting of inductance in MIG mode. In pulse and Accu-pulse mode, this adjustment changes
the arc cone by adjusting the preprogrammed factory pulse data.
Inductance
In short circuit GMAW welding, an increase in inductance will decrease the number of short circuit
transfers per second (provided no other changes are made) and increase the arc-on time. The
increased arc-on time makes the welding puddle more fluid.
Adjust
Control knob used to change or set parameters and functions.
Sequence
Selecting Sequence will allow setting of preflow, start, crater, and postflow times and parameters.
Preflow
Setting a time value for gas flow prior to arc start.
Start
Provides voltage/arc adjust, wire feed rate, and time value for modified arc starts (which is only
adjustable with the HTML pages.
Crater
Allows setting of voltage/arc adjust, wire feed rate, and time value for arc ends.
OM-245 592 Page 18
General Terms:
Postflow
Setting a time value for gas flow after arc end.
Feeder Set Up
Allow selection of Sequence and trigger functions.
Auto Thread
Method of jogging wire without holding jog or trigger switch. By rocking the switch from purge to jog
within 0.5 seconds will automatically feed wire for a factory default setting of 192 in (4877 mm) of wire
before stopping. Default setting is 192 at a feed rate of 700 ipm (these values can be changed using
the HTML pages). Pressing jog, purge, or trigger switch will terminate the auto-threading feature.
5-2. Power Switch
1
Power Switch
1
803 504-A
OM-245 592 Page 19
5-3. Front Panel Controls
See
Section
5-5
See
Section
5-4
Program
Time
WFS
Amps
See
Section
5-6
Arc Adjust
Arc Ctl
Process
Sequence
Wire Type
Trigger Control
Gas Type
Trigger Hold
Process Set Up
See
Section
5-9
OM-245 592 Page 20
Volts
Adjust
See
Section
5-8
Feeder Set Up
See
Section
5-7
5-4. Program Push Button
1
Program Display
The number of the active program
is displayed.
2
3
Program Push Button
Program Push Button LED
The LED lights to indicate that
programs can be changed using
the Adjust knob.
1
Program
Momentarily press button to
illuminate LED. To change the
program number, rotate Adjust knob
to select one of eight programs.
3
2
Pressing and holding the push
button will display current wire size,
wire type and process.
5-5. Upper Display
3
1
2
4
Volts
Arc Adjust
5
1
Upper Display
The upper display shows voltage or arc
length. The unit displays both preset voltage
or arc length and actual voltage. When
welding, actual arc voltage is displayed.
2
Upper Display Push Button
Press the button to illuminate the LED and
allow changing information in the display.
Release button to display voltage.
4
5
3
The LEDs below the display illuminate to
indicate which value is being shown.
Upper Display Push Button LED
The upper display push button LED
illuminates to indicate that information
displayed can be changed by the Adjust
control.
Volts LED (Weld Voltage In MIG)
Arc Adjust LED (Pulse Mode)
At any time while welding, the unit permits the
adjustment of the weld voltage and overrides
the display of actual arc voltage.
OM-245 592 Page 21
5-6. Lower Display
5
7
Time
1
6
2
WFS
Amps
Arc Ctl
3
1
Lower Display
The lower display shows WFS (wire feed
speed), AMPS (amperage), ARC CTL (arc
control), or Time. The feeder displays only
preset wire speed at idle (not welding). While
welding, the average amperage is displayed.
The lower display shows welding sequence
time when the Time LED is illuminated.
2
WFS (Wire Feed Speed) LED
LED illuminates to indicate the preset wire feed
value is being displayed and can be adjusted
using the Adjust knob.
3
Amps LED
LED illuminates to indicate the average
amperage is being displayed while welding
and for 3 seconds after welding is terminated.
The amperage must be above a minimum
value of 25 amps for this function to operate.
OM-245 592 Page 22
4
4 Arc Ctl (Arc Control) LED
LED illuminates to indicate that inductance
(MIG) or ARC (Pulse or Accu-pulse) is being
displayed and can be adjusted using the
Adjust knob.
5 Time LED
LED illuminates to indicate that a time value is
being displayed for a sequence function and
can be adjusted using the Adjust knob.
6 Lower Display Push Button
7 Lower Display Push Button LED
Pressing the button illuminates the LED and
selects either WFS or Arc Ctl value for
changing using the Adjust knob.
To select Arc Ctl, press and hold lower display
button for 2 seconds. The top display will show
either INDU for a MIG program or ARC for
Pulse or Accu-pulse. To exit Arc Ctl or INDU,
either press the upper display push button or
press and hold the lower display push button
for 2 seconds.
During a welding program operation, it is
possible to change WFS (wire feed speed) by
using the Adjust knob regardless of the active
program sequence that appears on the
display.
When the Arc Ctl LED is illuminated, it is
possible to change values while welding by
using the Adjust knob. To return to actual
values on the display, exit the Arc Ctl display.
. The
lower display push button has
additional functions when entering the
sequence and trigger control functions
(see Section 5-7).
5-7. Feeder Set Up Push Button
3
4
Sequence
5
Trigger Control
Start
Time
Trigger Hold
2
1
Weld
Time
Crater
Time
Preflow
Time
Postflow
Time
6
Welding Sequence Diagram
Feeder Set Up
1 Feeder Set Up Push Button
2 Feeder Set Up Push Button LED
Press button to choose sequence, trigger
control, or trigger hold.
3 Sequence LED
4 Trigger Control LED
5 Trigger Hold LED
• When the Feeder Set Up button is pressed
while in standby, the Feeder Set Up push
button LED illuminates and the top display
will be active. Use the Adjust control to
select preflow (PRE), start (STRT), crater
(CRTR), or postflow (POST) parameters.
• Press the lower display push button to allow
the bottom display to become active. The
time LED will automatically begin flashing
and the unit will be in the time mode. Initially,
all sequences will appear as off. Use the
Adjust control display time and enable the
time sequence. Setting a time automatically
enables a sequence. To turn off a sequence,
change time setting to OFF.
• If the sequence has a voltage or arc adjust
setting, pressing the lower display push
button a second time will cause either volts
or arc adjust to appear on the display. Use
the Adjust control to set either parameter.
• If the sequence has a wire feed setting,
pressing the lower display push button a
third time will cause wfs to appear on the
display. Use the Adjust control to set wire
speed parameter. Additional sequence set
up changes can be made using the HTML
pages. Refer to the HTML Owner’s Manual
for additional information.
• Press the lower display push button a fourth
time will cycle the display back to time.
• Press the Feeder Set Up button a second
time to go to Trigger Control mode and allow
the top display to become active. Use the
Adjust control to cycle through trigger
control methods as follows: dual schedule,
trigger hold, trigger dual schedule, program
select, 4T (see Section 5-1 and Table 5-1).
The lower display will show the current state
•
•
6
•
of each trigger control method as being
either on or off. Not all trigger control
methods are compatible with each other,
and turning on certain functions will cause
other trigger functions to turn off.
Press the lower display push button to allow
the bottom display to become active. Use
the Adjust control to turn selected trigger
control methods on or off. If trigger hold is
set to on, the trigger hold LED will illuminate.
Note: if 4T is set to on, trigger hold will
automatically be set to on since this
parameter is necessary for the 4T function.
Press the Feeder Set Up button a third time
to cycle back to standby mode.
Lock LED
The lock LED is illuminated when one or more
programs have been locked using the HTML
pages. This indicates that some programs
have been disabled. A disabled program will
not show up for selection.
Refer to the HTML Owner’s Manual for
additional information.
Table 5-1. Trigger Control Chart
Trigger Control
Function
Trigger Hold
4T
Trigger Dual
Schedule
Trigger Program
Select
Dual Schedule
Trigger Hold
X
Yes
No
Yes
Yes
4T
Yes
X
No
Yes
No
Trigger Dual
Schedule
No
No
X
Yes
No
Trigger Program
Select
Yes
Yes
Yes
X
Yes
Dual Schedule
Yes
No
No
Yes
X
The following trigger control functions are the possible selections that limit the choices that appear on the display depending upon which one
the user turns on. Only certain trigger functions will work with the other trigger functions.
OM-245 592 Page 23
5-8. Adjust Control
1
1
Adjust Control
The Adjust control is used to
change
various
sequence
parameters, and to select various
sequences. Refer to the section for
the function in question for
information related to using the
Adjust control.
Adjust
5-9. Process Set Up Push Button
3
1
2
3
Process
Process Set Up Push Button
Process Set Up LED
Program Selection LEDs
Wire Type
Gas Type
2
1
Process Set Up
• Press the Process Set Up push button the
first time will illuminate the button LED and
Process LED above the button. Both
displays will show the current process and,
if desired, these displays will be active to
allow selecting a new process. Default
processes are MIG, PULSE, and ACCU
PULSE.
• Pressing the Process Set Up push button a
second time will illuminate the Wire Type
LED and the bottom display will show wire
OM-245 592 Page 24
types available for the selected process. To
make a selection, rotate the Adjust control.
and wire size selection. To select an item,
rotate the Adjust control.
• Pressing the Process Set Up push button a
third time will keep Wire Type LED lit, but the
upper display will be active and show wire
sizes available for the current wire type. To
make a selection, rotate the Adjust control.
• Pressing the Process Set Up push button a
fifth time will load the program that matches
the selected parameters (process, wire
type, wire size, gas). The upper display will
show PROG and the lower display will show
LOAD.
• Pressing the Process Set Up push button a
fourth time will illuminate the Gas Type LED
and both displays will show available gas
selections for the process, and wire type
If no changes were made to any setup items,
no program will be loaded, and unit will return
to standby mode.
Table 5-2. Welding Wire And Gas Abbreviations*
Wire Description
Wire Abbreviation
Alloy Type
Gas Type
Gas Abbreviation
Steel
STL
E70, E100, E120
100% CO2,
90% Argon/10% CO2,
85% Argon/15% CO2,
75% Argon/25% CO2,
95% Argon/5% CO2,
95% Argon /5% O2,
98% Argon/2% O2
CO2
C10
C15
C25
C5
OX5
OX2
Stainless Steel
SS
308, 309, 312, 316
98% Argon, 2% O2
(81Ar/18HE/1CO2
Accu-pulse)
90HE/7-1/2Ar/2-1/2CO 2
MIG/Accu-pulse)
OX2
Tri Gas
71, 76, 86R, 409,
439, MATRIX
90% Argon/10% CO2
C10
98% Argon/2% O2
OX2
4XXX, 5XXX
100% Argon
ARGN
Cored Tubular Wire
MCOR
Aluminum
ALUM
Tri Gas
* Not all wire types may be available with your unit.
5-10. Jog/Purge
1
2
3
Jog/Purge Push Button
Adjust Control
Gun Trigger Receptacle
2
3
1
803 505-A
The Jog/Purge switch provides the following
functions:
• Pressing left side of the Jog/Purge switch
allows the operator to feed wire without
energizing the weld power or gas valve
circuit. The wire will feed at a 60 ipm rate for
3 seconds, then the rate ramps up to 700
ipm until the Jog switch is released.
• Jog speed can be adjusted by modifying the
minimum and maximum speed limits using
the HTML pages.
• The unit also provides the ability to jog the
wire feeder by means of the gun trigger.
When the gun trigger is pressed without
starting an arc, the wire will feed at run-in
speed for the first 3 seconds. During this
time OCV (open circuit voltage) will be
present as indicated on the feeder upper
display. After 3 seconds the weld output
turns off and the wire will feed at 60 ipm for
the next 3 seconds and then ramps up to
700 ipm until trigger is released or 30
seconds elapses. If the gun trigger is still
activated after 30 seconds, the jog
operation is terminated to prevent complete
unspooling of the wire and an “REL TRIG”
message is displayed on the upper and
lower displays. Press the Jog/Purge switch
to clear the error.
. If Start Error is enabled using the HTML
pages, an “ERR STRT” will occur after the
first 3 seconds of run in and jogging from
the trigger is not possible.
• Pressing right side of the Jog/Purge switch
allows the operator to purge gas lines before
welding and to preset gas flow rate at the
regulator.
• This unit is equipped with Auto Thread
capability. By rocking the switch from purge
to jog within 0.5 seconds will automatically
feed wire for a factory default setting of 192
in (4877 mm) of wire before stopping. The
default feed rate is 700 ipm. These settings
can be changed using the HTML pages.
OM-245 592 Page 25
5-11. User Interface Menu
1
2
1
2
Welding Power Source
Wire Feeder
Turn on welding power source and
ROI.
Wait for system to initialize (see
Section 4-6).
To enter the user interface menu,
momentarily press the Program
push button and lower display push
button at the same time.
Example display shows
a model 450
Program
AXCS
Volts
Time
450
WFS
Amps
Arc Ctl
Sequence
Trigger Control
Process
Wire Type
Gas Type
Process Set up
Arc Adjust
Trigger Hold
Adjust
Feeder Set Up
245 746-A / 803 504-B
OM-245 592 Page 26
A. System Reset
. System Reset is not active when
Program
CAC
Volts
Time
ENBL
WFS
Amps
Program
Arc Adjust
Volts
Time
System Reset allows the operator to
reload factory program settings for all
eight active programs in the unit.
Arc Adjust
RST
Arc Ctl
WFS
Sequence
Trigger Control
Process
Wire Type
Gas Type
Trigger Hold
Process Set up
Program Lock is enabled.
SYS
Adjust
Feeder Set Up
After entering the user interface
menu, the initial display will vary by
the first item that appears.
Amps
Arc Ctl
Sequence
Trigger Control
Process
Wire Type
Gas Type
Trigger Hold
Process Set up
Adjust
. System configuration data will be
lost during the Reset operation.
Feeder Set Up
Rotate Adjust knob until System Reset
(SYS RST) appears on the display.
LED
Program
SYS
Volts
Time
RST
WFS
Amps
Program
Arc Adjust
WFS
Sequence
Trigger Control
Trigger Hold
Process Set up
Adjust
Feeder Set Up
Upper display push button LED
flashes to indicate this menu item
is available for selection. Press
the upper display push button.
Program
RST
Volts
Time
YES
WFS
Amps
Process Set up
Amps
Adjust
Feeder Set Up
Rotate Adjust knob to change NO
to YES.
PLS
Volts
WFS
The Set Up push button LED flashes
indicating the unit is ready to perform
the system reset operation. Press the
Set Up push button.
Arc Ctl
Trigger Hold
Time
WAIT
Feeder Set Up
Arc Adjust
Sequence
Trigger Control
Process Set up
Arc Ctl
Trigger Hold
Adjust
Time
Process
Wire Type
Gas Type
Program
Arc Adjust
Sequence
Trigger Control
Process
Wire Type
Gas Type
Volts
NO
Arc Ctl
Process
Wire Type
Gas Type
RST
Amps
Arc Ctl
Sequence
Trigger Control
Process
Wire Type
Gas Type
Process Set up
Arc Adjust
Program 1
Pulse
.035 Mild Steel
90% Argon, 10% CO2
Program 2
MIG
.035 Mild Steel
75% Argon, 25% CO2
Program 3
Accu-pulse
.035 Mild Steel
90% Argon, 10% O2
Program 4
Pulse
.045 Mild Steel
90% Argon, 10% CO2
Program 5
MIG
.045 Mild Steel
75% Argon, 25% CO2
Program 6
Accu-pulse
.045 Mild Steel
90% Argon, 10% O2
Program 7
Pulse
.052 Mild Steel
90% Argon, 10% CO2
Program 8
MIG
.052 Mild Steel
75% Argon, 25% CO2
Trigger Hold
Adjust
Feeder Set Up
Unit will go through a soft boot and then
begin initialization (see Section 4-6).
During system reset the following
factory default programs are loaded into
the unit:
OM-245 592 Page 27
B. Software Revision
Program
SYS
Volts
Time
RST
WFS
Amps
Program
Arc Adjust
SW
Volts
Time
Arc Adjust
REV
Arc Ctl
WFS
Sequence
Trigger Control
Process
Wire Type
Gas Type
Trigger Hold
Process Set up
The top display shows the board
(PCM, UIM, and WFCM) and the
lower display shows the last 3 digits of
the circuit board part number plus a
letter designator.
Adjust
Feeder Set Up
After entering the user interface
menu, the initial display will vary by
the first item that appears.
Amps
Arc Ctl
Sequence
Trigger Control
Process
Wire Type
Gas Type
Trigger Hold
Process Set up
Adjust
Feeder Set Up
Rotate Adjust knob until Software
Revision (SW REV) appears on
the display.
LED
Program
SW
Volts
Time
REV
WFS
Amps
Program
Arc Adjust
Trigger Hold
Adjust
Feeder Set Up
Upper display push button LED
flashes to indicate this menu item
is available for selection. Press
the upper display push button.
Program
PCM
Volts
Time
321B
WFS
Amps
Process Set up
Adjust
25
Volts
Time
200
WFS
The Set Up push button LED flashes
indicating that pressing this button will
exit the user interface menu. Press
the Set Up push button.
OM-245 592 Page 28
Trigger Hold
Feeder Set Up
Rotate Adjust knob to scroll
through the software revision for
each circuit board.
Arc Ctl
Feeder Set Up
Arc Ctl
Sequence
Trigger Control
Process Set up
1
Trigger Hold
Adjust
Amps
Arc Adjust
Process
Wire Type
Gas Type
Program
Arc Adjust
Sequence
Trigger Control
Process
Wire Type
Gas Type
Time
WFS
Sequence
Trigger Control
Process Set up
Volts
123A
Arc Ctl
Process
Wire Type
Gas Type
UIM
Amps
Arc Ctl
Sequence
Trigger Control
Process
Wire Type
Gas Type
Process Set up
Arc Adjust
Trigger Hold
Adjust
Feeder Set Up
Unit goes back to its standby status.
C. Carbon Arc Cutting (CAC)
Program
SW
Volts
Time
REV
WFS
Amps
Program
Arc Adjust
CAC
Volts
Time
. CAC can be loaded on any of the
Arc Adjust
ENBL
Arc Ctl
WFS
Sequence
Trigger Control
Process
Wire Type
Gas Type
Trigger Hold
Process Set up
Allows carbon arc cutting to be
enabled or disabled.
Adjust
Feeder Set Up
After entering the user interface
menu, the initial display will vary by
the first item that appears.
Amps
Arc Ctl
Sequence
Trigger Control
Process
Wire Type
Gas Type
eight programs by selecting the
process using the Process Set up
button.
Trigger Hold
Process Set up
Adjust
Feeder Set Up
Rotate Adjust knob until Carbon
Arc Cutting Enable (CAC ENBL)
appears on the display.
LED
Program
CAC
Volts
Time
ENBL
WFS
Amps
Program
Arc Adjust
Trigger Hold
Adjust
Feeder Set Up
Upper display push button LED
flashes to indicate this menu item
is available for selection. Press
the upper display push button.
Program
ENBL
Volts
Time
YES
WFS
Amps
Process Set up
Trigger Hold
Adjust
25
Volts
WFS
The Set Up push button LED flashes
indicating that pressing this button will
enable carbon arc cutting. Press the
Set Up push button.
Feeder Set Up
Rotate Adjust knob to change NO
to YES.
Time
200
Feeder Set Up
Arc Ctl
Sequence
Trigger Control
Process Set up
Arc Ctl
Trigger Hold
Adjust
Amps
Arc Adjust
Process
Wire Type
Gas Type
Program
Arc Adjust
Sequence
Trigger Control
Process
Wire Type
Gas Type
Time
WFS
Sequence
Trigger Control
Process Set up
Volts
NO
Arc Ctl
Process
Wire Type
Gas Type
ENBL
Amps
Arc Ctl
Sequence
Trigger Control
Process
Wire Type
Gas Type
Process Set up
Arc Adjust
Trigger Hold
Adjust
Feeder Set Up
Unit goes back to it standby status.
OM-245 592 Page 29
D. Voltage Feedback
Program
CAC
Volts
Time
ENBL
WFS
Amps
Program
Arc Adjust
VOLT
Volts
Time
Arc Adjust
FDBK
Arc Ctl
WFS
Sequence
Trigger Control
Process
Wire Type
Gas Type
Trigger Hold
Process Set up
Allows changing the voltage feedback
method from volt sense lead to stud
feedback.
Adjust
Feeder Set Up
After entering the user interface
menu, the initial display will vary by
the first item that appears.
Amps
Arc Ctl
Sequence
Trigger Control
Process
Wire Type
Gas Type
Trigger Hold
Process Set up
Adjust
Feeder Set Up
Rotate Adjust knob until Voltage
Feedback (VOLT FDBK) appears
on the display.
LED
Program
VOLT
Volts
Time
FDBK
WFS
Program
Arc Adjust
Amps
Trigger Hold
Adjust
Feeder Set Up
Upper display push button LED
flashes to indicate this menu item
is available for selection. Press
the upper display push button.
Program
FDBK
Volts
Time
VSNS
WFS
Amps
Process Set up
Adjust
Feeder Set Up
Rotate Adjust knob to change
from STUD to volt sense lead
(VSNS).
25
Volts
WFS
The Set Up push button LED flashes
indicating that pressing this button will
change the voltage feedback method.
Press the Set Up push button.
OM-245 592 Page 30
Trigger Hold
Time
200
Feeder Set Up
Arc Ctl
Sequence
Trigger Control
Process Set up
Arc Ctl
Trigger Hold
Adjust
Amps
Arc Adjust
Process
Wire Type
Gas Type
Program
Arc Adjust
Sequence
Trigger Control
Process
Wire Type
Gas Type
Time
WFS
Sequence
Trigger Control
Process Set up
Volts
STUD
Arc Ctl
Process
Wire Type
Gas Type
FDBK
Amps
Arc Ctl
Sequence
Trigger Control
Process
Wire Type
Gas Type
Process Set up
Arc Adjust
Trigger Hold
Adjust
Feeder Set Up
Unit goes back to its standby status.
E. Load Bank
Program
VOLT
Volts
Time
FDBK
WFS
Amps
Program
Arc Adjust
LOAD
Volts
Time
. Load Bank is a diagnostic tool for
Arc Adjust
BANK
Arc Ctl
WFS
Sequence
Trigger Control
Process
Wire Type
Gas Type
Trigger Hold
Process Set up
Allows setting the load bank feature
on or off.
Adjust
Feeder Set Up
After entering the user interface
menu, the initial display will vary by
the first item that appears.
Amps
Arc Ctl
Sequence
Trigger Control
Process
Wire Type
Gas Type
testing the power conversion
modules, not a welding process
selection.
Trigger Hold
Process Set up
Adjust
Feeder Set Up
Rotate Adjust knob until Load
Bank (LOAD BANK) appears on
the display.
LED
Program
LOAD
Volts
Time
Program
Arc Adjust
BANK
WFS
Amps
Trigger Hold
Adjust
Feeder Set Up
Upper display push button LED
flashes to indicate this menu item
is available for selection. Press
the upper display push button.
Program
BANK
Volts
Time
ON
WFS
Amps
Process Set up
Trigger Hold
Adjust
25
Volts
WFS
The Set Up push button LED flashes
indicating that pressing this button will
set the load bank feature on. Press
the Set Up push button.
Feeder Set Up
Rotate Adjust knob to change
from OFF to ON.
Time
200
Feeder Set Up
Arc Ctl
Sequence
Trigger Control
Process Set up
Arc Ctl
Trigger Hold
Adjust
Amps
Arc Adjust
Process
Wire Type
Gas Type
Program
Arc Adjust
Sequence
Trigger Control
Process
Wire Type
Gas Type
Time
WFS
Sequence
Trigger Control
Process Set up
Volts
OFF
Arc Ctl
Process
Wire Type
Gas Type
BANK
Amps
Arc Ctl
Sequence
Trigger Control
Process
Wire Type
Gas Type
Process Set up
Arc Adjust
Trigger Hold
Adjust
Feeder Set Up
Unit goes back to its standby status.
OM-245 592 Page 31
F. Spool Reset
Program
LOAD
Volts
Time
Program
Arc Adjust
Amps
Time
WFS
Arc Ctl
Sequence
Trigger Control
Process
Wire Type
Gas Type
Trigger Hold
Process Set up
Volts
Arc Adjust
RST
BANK
WFS
WIRE
Allows the operator to reset the
date/time when a new spool of wire is
installed to allow wire usage tracking.
Adjust
Feeder Set Up
After entering the user interface
menu, the initial display will vary by
the first item that appears.
Amps
Arc Ctl
Sequence
Trigger Control
Process
Wire Type
Gas Type
Trigger Hold
Process Set up
Adjust
Feeder Set Up
Rotate Adjust knob until Cable
Compensation (CABL COMP)
appears on the display.
LED
Program
WIRE
Volts
Time
RST
WFS
Amps
Program
Arc Adjust
Trigger Hold
Adjust
Feeder Set Up
Upper display push button LED
flashes to indicate this menu item
is available for selection. Press
the upper display push button.
Program
RST
Volts
Time
ON
WFS
Amps
Process Set up
Adjust
Feeder Set Up
Rotate Adjust knob to change
from OFF tO ON.
25
Volts
WFS
The Set Up push button LED flashes
indicating that pressing this button will
reset the wire installation date/time.
Press the Set Up push button.
OM-245 592 Page 32
Trigger Hold
Time
200
Feeder Set Up
Arc Ctl
Sequence
Trigger Control
Process Set up
Arc Ctl
Trigger Hold
Adjust
Amps
Arc Adjust
Process
Wire Type
Gas Type
Program
Arc Adjust
Sequence
Trigger Control
Process
Wire Type
Gas Type
Time
WFS
Sequence
Trigger Control
Process Set up
Volts
OFF
Arc Ctl
Process
Wire Type
Gas Type
RST
Amps
Arc Ctl
Sequence
Trigger Control
Process
Wire Type
Gas Type
Process Set up
Arc Adjust
Trigger Hold
Adjust
Feeder Set Up
Unit goes back to its standby status.
SECTION 6 − SETTING SEQUENCE PARAMETERS
6-1. Sequence Parameters In A Program
. For more information on
Sequence mode, see Feeder
Set Up Push Button in Section
5-7.
Sequence
Weld Time can only be set by using
the HTML pages.
Parameters
Seconds
If time is set to Off in Weld
sequence, welding continues until
gun trigger is released.
1. Preflow
Off-5.0
If time is set to zero in any timed
sequence except Weld, the
sequence is skipped.
2. Postflow
Off-5.0
. Maximum
Volts/Trim
IPM
3. Start
10.0-44.0/
0-99
40-1400/
0-99
Off-5.0
4. Crater
10.0-44.0/
0-99
40-1400/
0-99
Off-5.0
IPM may actually
be lower depending on wire
size and gas combination.
Additional sequence
changes can be made
HTML pages. Refer to
Owner’s Manual for
information.
set up
using the
the HTML
additional
X = Setting available.
Weld
Crater
Time
Preflow
Time
Start
Time
Postflow
Time
Time
Preflow
Trigger
Pressed
Start
Weld
Crater
Postflow Sequence
End
Trigger
Released
OM-245 592 Page 33
SECTION 7 − MAINTENANCE
7-1. Routine Maintenance
!
n = Check
Z = Change
~ = Clean
* To be done by Factory Authorized Service Agent
Every
3
Months
Disconnect power
before maintaining.
~ Weld Terminals
l Damaged Gas Hose
nl Cords
nl Gun Cables
nl Cracked Parts
OR
~ Drive Rolls
OM-245 592 Page 34
~ Inside Unit
during severe conditions.
l = Replace
l Unreadable Labels
Every
6
Months
. Maintain more often
Reference
nl Weld Cables
7-2. Diagnostics
The following error messages are shown on the
upper and lower displays to indicate specific errors.
Explanations are in the text below:
ERR
ERR
ERR
ERR
ERR
ERR
TACH
MOTR
WFS
STRT
STOP
FLOW
Indicates a
tachometer error.
Indicates a motor
error.
Indicates a wire
feed speed error.
Indicates an arc
start error.
Indicates an arc
stop error.
Indicates a gas
flow error.
ERR
ERR
ERR
ERR
ERR
ERR
COOL
GND
STUK
TEMP
LINE
ARC
Indicates a coolant
flow error.
Indicates a ground
current error.
ERR TACH
• The tach error occurs 2 seconds after the
loss of tachometer feedback. The motor
speed is regulated through the monitoring of
voltage and current. Press Jog/Purge
button to clear error.
ERR MOTR
• The motor error indicates that the motor
has been drawing too much current for too
long. To remedy this, reduce the wire feed
speed or the wire feeder torque load/duty
cycle. Press Jog/Purge button to clear error.
ERR WFS
• The wire feed speed error indicates actual
wire feed speed does not match wire feed
speed command. Press Jog/Purge button
to clear error.
ERR STRT
• The start error occurs if the user has the
trigger held for more than 3 seconds without
striking an arc, or if a valid arc voltage and
current is not detected. The 3 second arc
start error time can be changed using an
optional PDA with File Management
software.
Indicates a wire
stuck error.
Indicates a
temperature error.
Indicates a line
error.
Indicates an arc
error.
ERR STOP
ERR STUK
• The stop error occurs as result of
obstructions in the wire feed system or a
faulty wire drive system. Check wire feed
and wire drive systems. Press Jog/Purge
button to clear error.
• The stuck error occurs if the welding wire
sticks to the workpiece at the end of a weld.
May be caused by poor weld conditions.
The error may be cleared by cutting wire
from workpiece, and pressing the Jog/
Purge button.
ERR FLOW
• The flow error indicates no gas flow to the
gun. The error may be reset by
reestablishing gas flow to the gun, and then
pressing the Jog/Purge button.
ERR COOL
• The cool error indicates no coolant flow in
water flow switch option. The error may be
reset by reestablishing coolant flow to the
gun, and then pressing the Jog/Purge
button.
ERR TEMP
• The temperature error indicates welding
power source has overheated and
shutdown. The error may be cleared by
allowing unit to cool down, and pressing the
Jog/Purge button.
ERR LINE
ERR GND
• The line error indicates input power is
outside of unit operating range. Check and
correct input power. Press Jog/Purge
button to clear error.
• The ground current error occurs if weld
current is detected in the earth ground
connection. May be caused by a conductor
making contact with unit chassis. Check
and repair feeder weld connections. Press
Jog/Purge button to clear error.
• The arc error indicates an arc outage
occurred possibly from a wire feeder error
or power source error. Check wire feeder
and power source. Press Jog/Purge button
to clear error.
ERR ARC
OM-245 592 Page 35
7-2.
Diagnostics (Continued)
WELD
MOTR
PLS
OVER
LOW
E
WAIT
COM
WAIT
CRNT
WFS
STOP
Indicates a weld
cycle wait error.
Indicates a motor
communication error.
Indicates a UIM
communication error.
OVER
REL
ERR
AVER
TRIG
UNKN
Indicates an over
average current error.
Indicates a trigger
closed error.
Indicates an
overcurrent error.
Indicates a low WFS Indicates an
emergency stop error.
command error.
Indicates an
unknown error.
WELD WAIT
OVER CRNT
OVER AVER
• The weld wait error indicates unit was not
ready for a weld sequence. Press Jog/
Purge button to clear error.
• The over current error indicates welding
power source primary current is too high.
Check and correct input power. Press Jog/
Purge button to clear error.
MOTR COM
LOW WFS
• The over average error indicates that
current is outside the average range for the
set program parameters. Check and correct
program parameters. Press Jog/Purge
button to clear error.
• The motor communication error
indicates motor board lost data
communications. Press Jog/Purge button
to clear error.
• The low wire feed speed error indicates
actual wire feed speed is lower than wire
feed speed command. Check for
obstructions in the wire feed system or a
faulty wire drive system. Press Jog/Purge
button to clear error.
PLS WAIT
• The UIM communication error indicates
user
interface
board
lost
data
communications. Press Jog/Purge button
to clear error.
OM-245 592 Page 36
E STOP
• The emergency stop error occurs if the
user presses an emergency stop button.
Reset the emergency stop button and press
Jog/Purge button to clear error.
REL TRIG
• The release trigger error indicates the
user held the trigger when starting a weld
program Press Jog/Purge button to clear
error.
ERR UNKN
• The unknown error indicates a
malfunction in the system somewhere.
Cycle power off and back on again.
7-3. Troubleshooting
!
Disconnect power before troubleshooting
Trouble
Remedy
Wire feeds, shielding gas flows, but
electrode wire is not energized.
Check and secure weld cable connections (see Section 4-2).
Electrode wire feeding stops or feeds
erratically during welding.
Check gun trigger connection. See gun Owner’s Manual.
Check gun trigger. See gun Owner’s Manual.
Readjust hub tension and drive roll pressure (see Section 4-5).
Change to correct size drive roll (see Table 9-1).
Clean or replace dirty or worn drive roll.
Incorrect size or worn wire guides.
Replace contact tip or liner. See gun Owner’s Manual.
Remove weld spatter or foreign matter from around nozzle opening.
Have Factory Authorized Service Agency check drive motor or motor control board PC1.
Motor runs slowly.
Check for correct input voltage.
Wire feeder power is on, displays light
up, but unit is inoperative.
Check welding gun trigger leads for continuity, and repair leads or replace gun.
OM-245 592 Page 37
SECTION 8 − ELECTRICAL DIAGRAM
Figure 8-1. Circuit Diagram
OM-245 592 Page 38
211 005-E
OM-245 592 Page 39
SECTION 9 − PARTS LIST
. Hardware is common and
not available unless listed.
6
7
8
5
9
10
11
12
11
10
13
15
16
17
4 − Fig 9-3
3
14
22
2
18
1
19
20
21 − Fig 9-2
803 506-C
Figure 9-1. Main Assembly
OM-245 592 Page 40
Item
No.
Part
No.
Description
Quantity
Figure 9-1. Main Assembly
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
. . . . . . . . . . . . . . . 159 647
. . . . . . . . . . . . . . . 159 646
. . . . . . . . . . . . . . . 159 360
. . . . . . . . . . . . . . . . Fig 9-3
. . . . . . . . . . . . . . . 141 753
. . . . . . . . . . . . . . . 058 427
. . . . . . . . . . . . . . . 180 571
. . . . . . . . . . . . . . . 010 233
. . . . . . . . . . . . . . . 057 971
. . . . . . . . . . . . . . . 010 191
. . . . . . . . . . . . . . . 058 628
. . . . . . . . . . . . . . . 058 428
. . . . . . . . . . . . . . . 135 205
. . . . . . . . . . . . . . . 200 556
. . . . . . . . . . . . . . . 201 781
. . . . . . . . . . . . . . . 156 243
. . . . . . . . . . . . . . . 145 639
. . . . . . . . . . . . . . . 200 552
. . . . . . . . . . . . . . . 134 306
. . . . . . . . . . . . . . . 200 557
. . . . . . . . . . . . . . . . Fig 9-2
. . . . . . . . . . . . . . . 216 695
. . INSULATOR, motor clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CLAMP, motor base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . INSULATOR, screw machine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . DRIVE ASSEMBLY, wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . HUB & SPINDLE ASSEMBLY, (consisting of) . . . . . . . . . . . . . . . . . . . . . .
. . . . RING, retaining spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . SHAFT, support spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . SPRING, cprsn .970 OD x .120 wire x 1.250pld . . . . . . . . . . . . . . . . . .
. . . . WASHER, flat stl keyed 1.500dia x .125thk . . . . . . . . . . . . . . . . . . . . . .
. . . . WASHER, fbr .656 ID x 1.500 OD x .125thk . . . . . . . . . . . . . . . . . . . . .
. . . . WASHER, brake stl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . HUB, spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . NUT, stl slflkg hex reg .625-11 w/nylon insert . . . . . . . . . . . . . . . . . . . . .
. . SUPPORT, spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . KNOB, w/extension clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CLAMP, motor top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . STRIP, buna N compressed sheet .062 x 4.000 x 4.000 . . . . . . . . . . . . .
. . BASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . FOOT, rubber 1.250 dia x 1.375 high no 10 screw . . . . . . . . . . . . . . . . . .
. . STIFFENER, base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CONTROL BOX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CAPACITOR, w/terminals (.027UF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
4
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
4
1
1
1
*Recommended Spare Parts.
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-245 592 Page 41
. Hardware is common and
1
not available unless listed.
2
7
8
5
9
4
23
3
10
15
13
14
6
12
16
22
17
18
11
19
21
20
803 507-F
Figure 9-2. Control Box
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 9-2. Control Box (Fig 9-1 Item 21)
. . . 1 . . . . . . . . . . . . . . . 134 464
. . . 2 . . . . . . . . . . . . . . +212 781
. . . 3 . . . . . . . . . . . . . . *245 603
. . . 4 . . . . . . . . . . . . . . . 212 808
. . . 5 . . . . PC6 . . . . . *245594
. . . 6 . . . . . . . . . . . . . . . 236 991
. . . 7 . . . . . . . . . . . . . . . 010 494
. . . 8 . . . . . . . . . . . . . . . 236 047
. . . 9 . . . . RC1 . . . . . 211 018
. . . . . . PLG43,46,49,
72 . . . . . . 115 093
. . . 10 . . . . . . . . . . . . . . . 137 761
. . . 11 . . . . . . . . . . . . . . . 238 791
. . . 12 . . . . . . . . . . . . . . . 134 201
. . . 13 . . . . . . . . . . . . . . . 097 132
. . . 14 . . . . . . . . . . . . . . . 236 979
. . . 15 . . . . PC2 . . . . . 212 493
. . . 16 . . . . . S1 . . . . . . 213 632
. . . 17 . . . . PC1 . . . . . 212 459
. . . 18 . . . . RC4 . . . . . 048 282
. . . 19 . . . . . . . . . . . . . . . 211 085
OM-245 592 Page 42
..
..
..
..
..
..
..
..
..
LABEL, Warning General Precautionary . . . . . . . . . . . . . . . . . . . . . . . . . . .
WRAPPER, feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ASSY, panel/pc card/overlay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BAFFLE, pc mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CIRCUIT CARD ASSY, wire feed module w/program . . . . . . . . . . . . . . .
ENCLOSURE, motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BUSHING, snap−in nyl 1.375 id x 1.750 mtg hole . . . . . . . . . . . . . . . . . .
BUSHING, snap−in nyl 1.750 id x 2.000 mtg hole . . . . . . . . . . . . . . . . . .
CONNECTOR, circ 97/met 9 pin size 20 rcpt . . . . . . . . . . . . . . . . . . . . . .
1
1
1
1
1
1
1
1
1
. . . . HOUSING PLUG+SKTS, (service kit) . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . NUT, 750 npt 1.31 hex .27h nyl blk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . VALVE, 40VDC 2way custom port .054 orf w/frict . . . . . . . . . . . . . . . . . . .
. . STAND−OFF SUPPORT, pc card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . STAND−OFF SUPPORT, pc card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . ENCLOSURE, control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CIRCUIT CARD ASSY, motor filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . SWITCH, rocker dpdt 10A 250VAC/20A 30VAC on-none-on . . . . . . . . .
. . CIRCUIT CARD ASSY, trigger filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . RCPT W/SKTS, (service kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . PANEL, front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
4
4
1
1
1
1
1
1
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 9-2. Control Box (Fig 9-1 Item 21) (Continued)
. . . 20 . . . . . . . . . . . . . . .
.....................
. . . 21 . . . . . S2 . . . . . .
.....................
.....................
. . . 22 . . . . . . . . . . . . . . .
. . . 23 . . . . . . . . . . . . . . .
.....................
.....................
.....................
.....................
.....................
. . . . . . . . . PLG47 . . . .
. . . . . . . . . PLG48 . . . .
. . . . . . . . . . PLG4 . . . . .
. . . . . . . . . PLG81 . . . .
. . . . . . . . . PLG10 . . . .
. . . . . . . . . PLG50 . . . .
. . . . . . . . . PLG44 . . . .
. . . . . . . . . PLG45 . . . .
. . . . . . . . . PLG42 . . . .
. . . . . . . . . PLG40 . . . .
.....................
245593
210 998
200 295
131 056
131 052
179 851
216 866
216 696
038 855
224 383
216 872
213 004
115 094
202 592
136 810
115 092
130 203
136 810
131 058
188 352
131 054
201 665
098 691
. . NAMEPLATE, lower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . SWITCH ASSY, jog/purge (including) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . SWITCH, rocker spdt 15A 12V (on)-off-(on) . . . . . . . . . . . . . . . . . . . . .
. . . . HOUSING PLUG+SKTS, (service kit) . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . HOUSING PLUG+SKTS, (service kit) . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . KNOB, pointer 1.670 dia x .250 id push on w/spring . . . . . . . . . . . . . . . .
. . FILTER ASSY, sense lead (including) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . CAPACITOR, w/terminals (.027UF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . BLOCK, term 20 amp 2 pole screw term . . . . . . . . . . . . . . . . . . . . . . . .
. . . . RESISTOR, w/terminals (2 K 5 watt) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . CABLE, volt sense 7 in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . CABLE, volt sense . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . HOUSING PLUG+SKTS, (service kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . HOUSING PLUG+SKTS, (service kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . HOUSING PLUG+SKTS, (service kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . HOUSING PLUG+SKTS, (service kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . HOUSING PLUG+SKTS, (service kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . HOUSING PLUG+SKTS, (service kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . HOUSING PLUG+SKTS, (service kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . HOUSING RCPT+SKTS, (service kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . HOUSING RCPT+SKTS, (service kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . HOUSING RCPTPLUG+SKTS, (service kit) . . . . . . . . . . . . . . . . . . . . . . .
. . STAND−OFF, no 6-32 x .500 lg .250 hex stl m&f . . . . . . . . . . . . . . . . . . .
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
*Recommended Spare Parts.
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-245 592 Page 43
. Hardware is common and
11
not available unless listed.
18
12
13
14
See Table 9-1 For
Drive Roll & Wire Guide Kits
15
16
17
9
1
2
3
4
5
7
6
8
18
19
10
15
20
33
30
21
22
23
24
32
31
25
35
26
29
27
28
34
3
4
6
5
2
1
802 950-B
Figure 9-3. Drive Assembly, Wire
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 9-3. Drive Assembly, Wire (Fig 9-1 Item 4)
. . . 1 . . . . . . . . . . . . . . . 010 668
. . . 2 . . . . . . . . . . . . . . . 172 075
. . . 3 . . . . . . . . . . . . . . . 149 962
. . . 4 . . . . . . . . . . . . . . . 149 486
. . . 5 . . . . . . . . . . . . . . . 132 750
. . . 6 . . . . . . . . . . . . . . . 150 520
. . . 7 . . . . . . . . . . . . . . . 133 493
. . . 8 . . . . . . . . . . . . . . . 133 350
. . . 9 . . . . M1 . . . . . *213 005
. . . . . . . . . . . . . . . . . . . . . 203 631
. . . 10 . . . . . . . . . . . . . . . 182 415
. . . 11 . . . . . . . . . . . . . . . 203 640
. . . 12 . . . . . . . . . . . . . . . 203 641
. . . 13 . . . . . . . . . . . . . . . 182 156
. . . 14 . . . . . . . . . . . . . . . 182 155
. . . 15 . . . . . . . . . . . . . . . 132 746
. . . 16 . . . . . . . . . . . . . . . 203 633
. . . 17 . . . . . . . . . . . . . . . 203 632
. . . 18 . . . . . . . . . . . . . . . 133 739
. . . 19 . . . . . . . . . . . . . . . 203 637
. . . 20 . . . . . . . . . . . . . . {229 550
. . . . . . . . . . . . . . . . . . . . . 604 311
. . . . . . . . . . . . . . . . . . . . . 603 115
. . . 21 . . . . . . . . . . . . . . . 167 387
. . . 22 . . . . . . . . . . . . . . . 168 825
. . . 23 . . . . . . . . . . . . . . . 133 308
. . . 24 . . . . . . . . . . . . . . . 134 834
OM-245 592 Page 44
. . SCREW, cap stl sch .250-20 x 1.500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . CARRIER, drive roll w/components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . SPACER, carrier drive roll . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . PIN, rotation arm rocker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . ARM, pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . SPACER, flat stl .257 ID x .619 OD x .105 . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . RING, retaining ext .250 shaft x .025thk . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . PIN, hinge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . MOTOR, gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . PRESSURE ARM (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . PIN, cotter hair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . KNOB, w/extension short pressure arm . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . WASHER, flat stl SAE No. 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . SPRING, cprsn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . SPRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . BUSHING, spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . SHAFT, spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . CARRIER, shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . WASHER, flat buna .375 ID x .625 OD x .062thk . . . . . . . . . . . . . . . . . . 2
. . . . KNOB, w/extension long pressure arm . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . ENCODER, quadrature 500PPR incremental 5V shaftless . . . . . . . . . . . . 1
. . . . GROMMET, rbr .250 ID x .375mtg hole .062 groove . . . . . . . . . . . . . . . 1
. . WEATHER STRIPPING, adh .125 x .375 . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . SPACER, locating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . DRIVE, pinion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . RING, retaining ext .375 shaft x .025thk . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . HOSE, SAE .187 ID x .410 OD (order by ft) . . . . . . . . . . . . . . . . . . . . . . . 2ft
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 9-3. Drive Assembly, Wire (Fig 9-1 Item 4) (continued)
.....................
. . . 25 . . . . . . . . . . . . . . .
. . . 26 . . . . . . . . . . . . . . .
. . . 27 . . . . . . . . . . . . . . .
. . . 28 . . . . . . . . . . . . . . .
. . . 29 . . . . . . . . . . . . . . .
. . . 30 . . . . . . . . . . . . . . .
. . . 31 . . . . . . . . . . . . . . .
. . . 32 . . . . . . . . . . . . . . .
. . . 33 . . . . . . . . . . . . . . .
. . . 34 . . . . . . . . . . . . . . .
. . . 35 . . . . . . . . . . . . . . .
.....................
184 685
149 959
179 265
604 538
151 437
185 624
601 872
602 213
602 243
601 966
108 940
179 263
178 937
. . ADAPTER ASSY, gun/feeder LH (including) . . . . . . . . . . . . . . . . . . . . . . . .
. . . . FITTING, brs barbed M 3/16tbg x .312-24 . . . . . . . . . . . . . . . . . . . . . . . .
. . . . ADAPTER, gun/feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . WASHER, flat stl SAE .312 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . KNOB, plstc T 1.125 lg x .312-18 x 1.500 . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . SCREW, 010-32 x o.50 hexwhd .40D stl pld slffmg trilob . . . . . . . . . . . .
. . . . NUT, stl hex full fnsh .375-16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . WASHER, lock stl split .375 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . WASHER, flat stl std .375 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . SCREW, cap stl hexhd .375-16 x 1.250 . . . . . . . . . . . . . . . . . . . . . . . . . .
. . SCREW, cap stl hexhd .250-20 x .750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . COVER, drive roll (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . LABEL, warning electric shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
1
1
2
1
1
1
1
4
1
1
*Recommended Spare Parts.
{Have nearest Factory Authorized Service Agent replace encoder.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-245 592 Page 45
OM-245 592 Page 46
Inlet Guide
221030
221030
221030
229919
229919
Wire Sizes
.023 to .040 in. (0.6 to 1.0mm)
.045 to .052 in. (1.1 to 1.4mm)
1/16 to 5/64 in. (1.6 to 2mm)
3/32 to 7/64 in. (2.4 to 2.8mm)
1/8 in. (3.2mm)
Wire Guides
*Accommodates .045 and .047 (3/64 in) wire
**Requires a low *speed wire feeder
149522
149521
149520
149519
149518
Intermediate Guide
151042
151043**
151076**
151075
151074
151073
151072
151071
151070
”U” COGGED FOR
EXTREMELY SOFT
WIRE OR SOFT
*
SHELLED CORED
WIRES
1/16 in. (1.6mm)
.047 in. (1.2mm)
.035 in. (0.9mm)
Wire Size
221912
221912
221912
Inlet Guide
Nylon Wire Guides for Feeding Aluminum Wire
151060**
151059
151058
1/8 in. (3.2 mm)
151055
7/64 in. (2.8 mm)
151039
151054
151053
151041
151029
1/16 in. (1.6 mm)
151038
151037*
3/32 in. (2.4 mm)
151028
.052 in. (1.3/1.4 mm)
151057
151027
.045 in. (1.1/1.2 mm)
151056
161190
.040 in. (1.0 mm)
151052
151040
151026
.035 in. (0.9 mm)
”V” KNURLED FOR
HARD*SHELLED
CORED WIRES
5/64 in. (2.0 mm)
151025
.030 in. (0.8 mm)
”U” GROOVE FOR
SOFT*SHELLED
CORED WIRES
.068/.072 in. (1.8 mm)
151024
.023/.025 in. (0.6 mm)
WIRE SIZE
”V” GROOVE FOR
HARD WIRE
205937
205936
242417
Intermediate Guide
243235
243234*
243233
”U” GROOVE FOR
ALUMINUM WIRES
CONTAINS NYLON
WIRE GUIDES
Table 9-1. Drive Roll And Wire Guide Kits
Effective January 1, 2010
(Equipment with a serial number preface of MA or newer)
Warranty Questions?
Call
1-800-4-A-MILLER
for your local
Miller distributor.
Your distributor also gives
you ...
Service
You always get the fast,
reliable response you
need. Most replacement
parts can be in your
hands in 24 hours.
Support
Need fast answers to the
tough welding questions?
Contact your distributor.
The expertise of the
distributor and Miller is
there to help you, every
step of the way.
This limited warranty supersedes all previous Miller warranties and is exclusive with no other
guarantees or warranties expressed or implied.
LIMITED WARRANTY − Subject to the terms and conditions 6. 90 Days — Parts
below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants to its
* Accessory (Kits)
original retail purchaser that new Miller equipment sold after the
* Canvas Covers
effective date of this limited warranty is free of defects in material
* Induction Heating Coils and Blankets, Cables, and
and workmanship at the time it is shipped by Miller. THIS
Non-Electronic Controls
WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER
* M-Guns
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE
* MIG Guns and Subarc (SAW) Guns
WARRANTIES OF MERCHANTABILITY AND FITNESS.
* Remote Controls and RFCS-RJ45
Within the warranty periods listed below, Miller will repair or replace
* Replacement Parts (No labor)
any warranted parts or components that fail due to such defects in
* Roughneck Guns
material or workmanship. Miller must be notified in writing within
* Spoolmate Spoolguns
thirty (30) days of such defect or failure, at which time Miller will
provide instructions on the warranty claim procedures to be
followed.
Miller shall honor warranty claims on warranted equipment listed
below in the event of such a failure within the warranty time
periods. All warranty time periods start on the delivery date of the
equipment to the original end-user purchaser, and not to exceed
one year after the equipment is shipped to a North American
distributor or eighteen months after the equipment is shipped to an
International distributor.
1.
2.
3.
4.
5.
5 Years Parts — 3 Years Labor
* Original main power rectifiers only to include SCRs,
diodes, and discrete rectifier modules
3 Years — Parts and Labor
* Engine Driven Welding Generators
(NOTE: Engines are warranted separately by the
engine manufacturer.)
* Inverter Power Sources (Unless Otherwise Stated)
* Plasma Arc Cutting Power Sources
* Process Controllers
* Semi-Automatic and Automatic Wire Feeders
* Smith 30 Series Flowgauge and Flowmeter
Regulators (No Labor)
* Transformer/Rectifier Power Sources
* Water Coolant Systems (Integrated)
2 Years — Parts
* Auto-Darkening Helmet Lenses (No Labor)
1 Year — Parts and Labor Unless Specified
* Automatic Motion Devices
* CoolBelt and CoolBand Blower Unit (No Labor)
* External Monitoring Equipment and Sensors
* Field Options
(NOTE: Field options are covered for the remaining
warranty period of the product they are installed in, or
for a minimum of one year — whichever is greater.)
* Flowgauge and Flowmeter Regulators (No Labor)
* RFCS Foot Controls (Except RFCS-RJ45)
* Fume Extractors
* HF Units
* ICE Plasma Cutting Torches (No Labor)
* Induction Heating Power Sources, Coolers, and
Electronic Controls/Recorders
* Load Banks
* Motor Driven Guns (w/exception of Spoolmate
Spoolguns)
* PAPR Blower Unit (No Labor)
* Positioners and Controllers
* Racks
* Running Gear/Trailers
* Spot Welders
* Subarc Wire Drive Assemblies
* Water Coolant Systems (Non-Integrated)
* Weldcraft-Branded TIG Torches (No Labor)
* Work Stations/Weld Tables (No Labor)
6 Months — Parts
* Batteries
* Bernard Guns (No Labor)
* Tregaskiss Guns (No Labor)
Miller’s True Blue® Limited Warranty shall not apply to:
1.
2.
3.
Consumable components; such as contact tips,
cutting nozzles, contactors, brushes, relays, work
station table tops and welding curtains, or parts that
fail due to normal wear. (Exception: brushes and
relays are covered on all engine-driven products.)
Items furnished by Miller, but manufactured by others,
such as engines or trade accessories. These items are
covered by the manufacturer’s warranty, if any.
Equipment that has been modified by any party other than
Miller, or equipment that has been improperly installed,
improperly operated or misused based upon industry
standards, or equipment which has not had reasonable
and necessary maintenance, or equipment which has
been used for operation outside of the specifications for
the equipment.
MILLER PRODUCTS ARE INTENDED FOR PURCHASE AND
USE BY COMMERCIAL/INDUSTRIAL USERS AND PERSONS
TRAINED AND EXPERIENCED IN THE USE AND
MAINTENANCE OF WELDING EQUIPMENT.
In the event of a warranty claim covered by this warranty, the
exclusive remedies shall be, at Miller’s option: (1) repair; or (2)
replacement; or, where authorized in writing by Miller in
appropriate cases, (3) the reasonable cost of repair or
replacement at an authorized Miller service station; or (4) payment
of or credit for the purchase price (less reasonable depreciation
based upon actual use) upon return of the goods at customer’s risk
and expense. Miller’s option of repair or replacement will be F.O.B.,
Factory at Appleton, Wisconsin, or F.O.B. at a Miller authorized
service facility as determined by Miller. Therefore no
compensation or reimbursement for transportation costs of any
kind will be allowed.
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR
DIRECT,
INDIRECT,
SPECIAL,
INCIDENTAL
OR
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF
PROFIT), WHETHER BASED ON CONTRACT, TORT OR ANY
OTHER LEGAL THEORY.
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND
ANY
IMPLIED
WARRANTY,
GUARANTY
OR
REPRESENTATION AS TO PERFORMANCE, AND ANY
REMEDY FOR BREACH OF CONTRACT TORT OR ANY
OTHER LEGAL THEORY WHICH, BUT FOR THIS PROVISION,
MIGHT ARISE BY IMPLICATION, OPERATION OF LAW,
CUSTOM OF TRADE OR COURSE OF DEALING, INCLUDING
ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR PARTICULAR PURPOSE, WITH RESPECT TO
ANY AND ALL EQUIPMENT FURNISHED BY MILLER IS
EXCLUDED AND DISCLAIMED BY MILLER.
Some states in the U.S.A. do not allow limitations of how long an
implied warranty lasts, or the exclusion of incidental, indirect,
special or consequential damages, so the above limitation or
exclusion may not apply to you. This warranty provides specific
legal rights, and other rights may be available, but may vary from
state to state.
In Canada, legislation in some provinces provides for certain
additional warranties or remedies other than as stated herein, and
to the extent that they may not be waived, the limitations and
exclusions set out above may not apply. This Limited Warranty
provides specific legal rights, and other rights may be available,
but may vary from province to province.
miller_warr 2010−01
Owner’s Record
Please complete and retain with your personal records.
Model Name
Serial/Style Number
Purchase Date
(Date which equipment was delivered to original customer.)
Distributor
Address
City
State
Zip
For Service
Contact a DISTRIBUTOR or SERVICE AGENCY near you.
Always provide Model Name and Serial/Style Number.
Contact your Distributor for:
Welding Supplies and Consumables
Options and Accessories
Personal Safety Equipment
Service and Repair
Miller Electric Mfg. Co.
An Illinois Tool Works Company
1635 West Spencer Street
Appleton, WI 54914 USA
Replacement Parts
Training (Schools, Videos, Books)
Technical Manuals (Servicing Information
and Parts)
Circuit Diagrams
For International Locations Visit
www.MillerWelds.com
Welding Process Handbooks
To locate a Distributor or Service Agency visit
www.millerwelds.com or call 1-800-4-A-Miller
Contact the Delivering Carrier to:
File a claim for loss or damage during
shipment.
For assistance in filing or settling claims, contact
your distributor and/or equipment manufacturer’s
Transportation Department.
ORIGINAL INSTRUCTIONS − PRINTED IN USA
International Headquarters−USA
USA Phone: 920-735-4505 Auto-Attended
USA & Canada FAX: 920-735-4134
International FAX: 920-735-4125
© 2010 Miller Electric Mfg. Co.
2010−01
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement