advertisement
▼
Scroll to page 2
of 40
OM-277 163 768P June 1998 Processes Multiprocess Welding Description Arc Welding Power Source Dimension 302, 452 (60 Hz), 372, 562 (50/60 Hz) Visit our website at www.MillerWelds.com From Miller to You Thank you and congratulations on choosing Miller. Now you can get the job done and get it done right. We know you don’t have time to do it any other way. That’s why when Niels Miller first started building arc welders in 1929, he made sure his products offered long-lasting value and superior quality. Like you, his customers couldn’t afford anything less. Miller products had to be more than the best they could be. They had to be the best you could buy. Today, the people that build and sell Miller products continue the tradition. They’re just as committed to providing equipment and service that meets the high standards of quality and value established in 1929. This Owner’s Manual is designed to help you get the most out of your Miller products. Please take time to read the Safety precautions. They will help you protect yourself against potential hazards on the worksite. We’ve made installation and operation quick and easy. With Miller you can count on years of reliable service with proper maintenance. And if for some reason the unit needs repair, there’s a Troubleshooting section that will help you Miller is the first welding figure out what the problem is. The parts list equipment manufacturer in will then help you to decide which exact part the U.S.A. to be registered you may need to fix the problem. Warranty and to the ISO 9001 Quality service information for your particular model System Standard. are also provided. Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual catalog sheets. To locate your nearest distributor call 1-800-4-A-Miller. Working as hard as you do − every power source from Miller is backed by the most hassle-free warranty in the business. Miller offers a Technical Manual which provides more detailed service and parts information for your unit. To obtain a Technical Manual, contact your local distributor. Your distributor can also supply you with Welding Process Manuals such as SMAW, GTAW, GMAW, and GMAW-P. TABLE OF CONTENTS The following terms are used interchangeably throughout this manual: MIG = GMAW OM-277P SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3. Additional Symbols for Installation, Operation, and Maintenance . . . . . . . . . . . . . . . . . . . . . . 1-4. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 1 − CONSIGNES DE SECURITE − LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . . 1-1. Signification des symboles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2. Dangers relatifs au soudage à l’arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5. Information sur les champs électromagnétiques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 2 − DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1. General Precautionary Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2. Input Connection Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3. Electric Shock And Airflow Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4. Nameplate Safety Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5. Manufacturer’s Rating Labels For CE Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 3 − INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2. Duty Cycle And Overheating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3. Volt-Ampere Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4. Selecting A Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5. Dimensions And Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6. Tipping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7. 115 VAC Receptacle And Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8. Weld Output Terminals And Selecting Cable Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9. Remote 14 Receptacle And Terminal Strip 1T Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10. Connecting Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11. Electrical Service Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12. Placing Jumper Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13. Connecting Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 4 − OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1. Controls (Non CE Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2. Controls (CE Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 5 − MAINTENANCE & TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2. Fuse F1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 6 − ELECTRICAL DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 7 − PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OPTIONS AND ACCESSORIES WARRANTY 1 1 1 3 3 4 5 5 5 7 8 8 9 9 10 10 10 11 12 12 12 13 14 14 15 15 16 16 17 18 19 20 21 21 22 23 23 23 24 25 26 Declaration of Conformity For European Community (CE) Products NOTE This information is provided for units with CE certification (see rating label on unit.) Miller Electric Mfg. Co. Manufacturer’s Name: 1635 W. Spencer Street Appleton, WI 54914 USA Manufacturer’s Address: Declares that the product: Dimension™ 372 And 562 conforms to the following Directives and Standards: Directives Electromagnetic compatibility Directives: 89/336/EEC, 92/31/EEC Low Voltage Directive: 73/23/EEC Machinery Directives: 89/392/EEC, 91/368/EEC, 93/C 133/04, 93/68/EEC Standards Safety Requirements for Arc Welding Equipment part 1: EN 60974-1: 1990 Arc Welding Equipment Part 1: Welding Power Sources: IEC 974-1 (April 1995 − Draft revision) Degrees of Protection provided by Enclosures (IP code): IEC 529: 1989 Insulation coordination for equipment within low-voltage systems: Part 1: Principles, requirements and tests: IEC 664-1: 1992 Electromagnetic compatibility (EMC) Product standard for arc welding equipment: EN50199: August 1995 European Contact: Telephone: Fax: dec_con1 10/95 Mr. Luigi Vacchini, Managing Director MILLER Europe S.P.A. Via Privata Iseo 20098 San Giuliano Milanese, Italy 39(02)98290-1 39(02)98281-552 SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _nd_5/97 1-1. Symbol Usage Means Warning! Watch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. Y Marks a special safety message. . Means “Note”; not safety related. This group of symbols means Warning! Watch Out! possible ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult symbols and related instructions below for necessary actions to avoid the hazards. 1-2. Arc Welding Hazards Y The symbols shown below are used throughout this manual to call attention to and identify possible hazards. When you see the symbol, watch out, and follow the related instructions to avoid the hazard. The safety information given below is only a summary of the more complete safety information found in the Safety Standards listed in Section 1-4. Read and follow all Safety Standards. D If earth grounding of the workpiece is required, ground it directly with a separate cable − do not use work clamp or work cable. Y Only qualified persons should install, operate, maintain, and repair this unit. D Wear a safety harness if working above floor level. D Keep all panels and covers securely in place. Y During operation, keep everybody, especially children, away. D Clamp work cable with good metal-to-metal contact to workpiece or worktable as near the weld as practical. ELECTRIC SHOCK can kill. Touching live electrical parts can cause fatal shocks or severe burns. The electrode and work circuit is electrically live whenever the output is on. The input power circuit and machine internal circuits are also live when power is on. In semiautomatic or automatic wire welding, the wire, wire reel, drive roll housing, and all metal parts touching the welding wire are electrically live. Incorrectly installed or improperly grounded equipment is a hazard. D Do not touch electrode if you are in contact with the work, ground, or another electrode from a different machine. D Use only well-maintained equipment. Repair or replace damaged parts at once. Maintain unit according to manual. D Insulate work clamp when not connected to workpiece to prevent contact with any metal object. D Do not connect more than one electrode or work cable to any single weld output terminal. SIGNIFICANT DC VOLTAGE exists after removal of input power on inverters. D Turn Off inverter, disconnect input power, and discharge input capacitors according to instructions in Maintenance Section before touching any parts. D Do not touch live electrical parts. D Wear dry, hole-free insulating gloves and body protection. D Insulate yourself from work and ground using dry insulating mats or covers big enough to prevent any physical contact with the work or ground. D Do not use AC output in damp areas, if movement is confined, or if there is a danger of falling. D Use AC output ONLY if required for the welding process. D If AC output is required, use remote output control if present on unit. D Disconnect input power or stop engine before installing or servicing this equipment. Lockout/tagout input power according to OSHA 29 CFR 1910.147 (see Safety Standards). D Properly install and ground this equipment according to its Owner’s Manual and national, state, and local codes. D Keep your head out of the fumes. Do not breathe the fumes. D Always verify the supply ground − check and be sure that input power cord ground wire is properly connected to ground terminal in disconnect box or that cord plug is connected to a properly grounded receptacle outlet. D When making input connections, attach proper grounding conductor first − double-check connections. D Frequently inspect input power cord for damage or bare wiring − replace cord immediately if damaged − bare wiring can kill. D Turn off all equipment when not in use. D Do not use worn, damaged, undersized, or poorly spliced cables. D Do not weld in locations near degreasing, cleaning, or spraying operations. The heat and rays of the arc can react with vapors to form highly toxic and irritating gases. D Do not drape cables over your body. FUMES AND GASES can be hazardous. Welding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health. D If inside, ventilate the area and/or use exhaust at the arc to remove welding fumes and gases. D If ventilation is poor, use an approved air-supplied respirator. D Read the Material Safety Data Sheets (MSDSs) and the manufacturer’s instructions for metals, consumables, coatings, cleaners, and degreasers. D Work in a confined space only if it is well ventilated, or while wearing an air-supplied respirator. Always have a trained watchperson nearby. Welding fumes and gases can displace air and lower the oxygen level causing injury or death. Be sure the breathing air is safe. D Do not weld on coated metals, such as galvanized, lead, or cadmium plated steel, unless the coating is removed from the weld area, the area is well ventilated, and if necessary, while wearing an air-supplied respirator. The coatings and any metals containing these elements can give off toxic fumes if welded. OM-277 Page 1 ARC RAYS can burn eyes and skin. Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld. D Wear a welding helmet fitted with a proper shade of filter to protect your face and eyes when welding or watching (see ANSI Z49.1 and Z87.1 listed in Safety Standards). D Wear approved safety glasses with side shields under your helmet. D Use protective screens or barriers to protect others from flash and glare; warn others not to watch the arc. D Wear protective clothing made from durable, flame-resistant material (leather and wool) and foot protection. BUILDUP OF GAS can injure or kill. D Shut off shielding gas supply when not in use. D Always ventilate confined spaces or use approved air-supplied respirator. HOT PARTS can cause severe burns. D Do not touch hot parts bare handed. D Allow cooling period before working on gun or torch. MAGNETIC FIELDS can affect pacemakers. WELDING can cause fire or explosion. Welding on closed containers, such as tanks, drums, or pipes, can cause them to blow up. Sparks can fly off from the welding arc. The flying sparks, hot workpiece, and hot equipment can cause fires and burns. Accidental contact of electrode to metal objects can cause sparks, explosion, overheating, or fire. Check and be sure the area is safe before doing any welding. D Protect yourself and others from flying sparks and hot metal. D Do not weld where flying sparks can strike flammable material. D Remove all flammables within 35 ft (10.7 m) of the welding arc. If this is not possible, tightly cover them with approved covers. D Be alert that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas. D Watch for fire, and keep a fire extinguisher nearby. D Be aware that welding on a ceiling, floor, bulkhead, or partition can cause fire on the hidden side. D Do not weld on closed containers such as tanks, drums, or pipes, unless they are properly prepared according to AWS F4.1 (see Safety Standards). D Connect work cable to the work as close to the welding area as practical to prevent welding current from traveling long, possibly unknown paths and causing electric shock and fire hazards. D Do not use welder to thaw frozen pipes. D Remove stick electrode from holder or cut off welding wire at contact tip when not in use. D Wear oil-free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes, and a cap. D Remove any combustibles, such as a butane lighter or matches, from your person before doing any welding. FLYING METAL can injure eyes. D Welding, chipping, wire brushing, and grinding cause sparks and flying metal. As welds cool, they can throw off slag. D Wear approved safety glasses with side shields even under your welding helmet. OM-277 Page 2 D Pacemaker wearers keep away. D Wearers should consult their doctor before going near arc welding, gouging, or spot welding operations. NOISE can damage hearing. Noise from some processes or equipment can damage hearing. D Wear approved ear protection if noise level is high. CYLINDERS can explode if damaged. Shielding gas cylinders contain gas under high pressure. If damaged, a cylinder can explode. Since gas cylinders are normally part of the welding process, be sure to treat them carefully. D Protect compressed gas cylinders from excessive heat, mechanical shocks, slag, open flames, sparks, and arcs. D Install cylinders in an upright position by securing to a stationary support or cylinder rack to prevent falling or tipping. D Keep cylinders away from any welding or other electrical circuits. D Never drape a welding torch over a gas cylinder. D Never allow a welding electrode to touch any cylinder. D Never weld on a pressurized cylinder − explosion will result. D Use only correct shielding gas cylinders, regulators, hoses, and fittings designed for the specific application; maintain them and associated parts in good condition. D Turn face away from valve outlet when opening cylinder valve. D Keep protective cap in place over valve except when cylinder is in use or connected for use. D Read and follow instructions on compressed gas cylinders, associated equipment, and CGA publication P-1 listed in Safety Standards. 1-3. Additional Symbols for Installation, Operation, and Maintenance FIRE OR EXPLOSION hazard. MOVING PARTS can cause injury. D Do not install or place unit on, over, or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit. D Keep away from moving parts such as fans. D Keep all doors, panels, covers, and guards closed and securely in place. FALLING UNIT can cause injury. H.F. RADIATION can cause interference. D Use lifting eye to lift unit only, NOT running gear, gas cylinders, or any other accessories. D Use equipment of adequate capacity to lift and support unit. D If using lift forks to move unit, be sure forks are long enough to extend beyond opposite side of unit. D OVERUSE can cause OVERHEATING D D Allow cooling period; follow rated duty cycle. D Reduce current or reduce duty cycle before starting to weld again. D Do not block or filter airflow to unit. D D D High-frequency (H.F.) can interfere with radio navigation, safety services, computers, and communications equipment. D Have only qualified persons familiar with electronic equipment perform this installation. The user is responsible for having a qualified electrician promptly correct any interference problem resulting from the installation. If notified by the FCC about interference, stop using the equipment at once. Have the installation regularly checked and maintained. Keep high-frequency source doors and panels tightly shut, keep spark gaps at correct setting, and use grounding and shielding to minimize the possibility of interference. STATIC (ESD) can damage PC boards. D Put on grounded wrist strap BEFORE handling boards or parts. D Use proper static-proof bags and boxes to store, move, or ship PC boards. ARC WELDING can cause interference. MOVING PARTS can cause injury. D Keep away from moving parts. D Keep away from pinch points such as drive rolls. D D WELDING WIRE can cause injury. D Do not press gun trigger until instructed to do so. D Do not point gun toward any part of the body, other people, or any metal when threading welding wire. D D D Electromagnetic energy can interfere with sensitive electronic equipment such as computers and computer-driven equipment such as robots. D Be sure all equipment in the welding area is electromagnetically compatible. To reduce possible interference, keep weld cables as short as possible, close together, and down low, such as on the floor. Locate welding operation 100 meters from any sensitive electronic equipment. Be sure this welding machine is installed and grounded according to this manual. If interference still occurs, the user must take extra measures such as moving the welding machine, using shielded cables, using line filters, or shielding the work area. 1-4. Principal Safety Standards Safety in Welding and Cutting, ANSI Standard Z49.1, from American Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126 Safety and Health Standards, OSHA 29 CFR 1910, from Superintendent of Documents, U.S. Government Printing Office, Washington, D.C. 20402. Recommended Safe Practices for the Preparation for Welding and Cutting of Containers That Have Held Hazardous Substances, American Welding Society Standard AWS F4.1, from American Welding Society, 550 N.W. LeJeune Rd, Miami, FL 33126 National Electrical Code, NFPA Standard 70, from National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, from Compressed Gas Association, 1235 Jefferson Davis Highway, Suite 501, Arlington, VA 22202. Code for Safety in Welding and Cutting, CSA Standard W117.2, from Canadian Standards Association, Standards Sales, 178 Rexdale Boulevard, Rexdale, Ontario, Canada M9W 1R3. Safe Practices For Occupation And Educational Eye And Face Protection, ANSI Standard Z87.1, from American National Standards Institute, 1430 Broadway, New York, NY 10018. Cutting And Welding Processes, NFPA Standard 51B, from National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. OM-277 Page 3 1-5. EMF Information Considerations About Welding And The Effects Of Low Frequency Electric And Magnetic Fields 1. Keep cables close together by twisting or taping them. Welding current, as it flows through welding cables, will cause electromagnetic fields. There has been and still is some concern about such fields. However, after examining more than 500 studies spanning 17 years of research, a special blue ribbon committee of the National Research Council concluded that: “The body of evidence, in the committee’s judgment, has not demonstrated that exposure to powerfrequency electric and magnetic fields is a human-health hazard.” However, studies are still going forth and evidence continues to be examined. Until the final conclusions of the research are reached, you may wish to minimize your exposure to electromagnetic fields when welding or cutting. 2. Arrange cables to one side and away from the operator. To reduce magnetic fields in the workplace, use the following procedures: Pacemaker wearers consult your doctor first. If cleared by your doctor, then following the above procedures is recommended. OM-277 Page 4 3. Do not coil or drape cables around your body. 4. Keep welding power source and cables as far away from operator as practical. 5. Connect work clamp to workpiece as close to the weld as possible. About Pacemakers: SECTION 1 − CONSIGNES DE SECURITE − LIRE AVANT UTILISATION som _nd_Fre 4/97 1-1. Signification des symboles Signifie Mise en garde ! Soyez vigilant ! Cette procédure présente des risques de danger ! Ceux-ci sont identifiés par des symboles adjacents aux directives. Y Identifie un message de sécurité particulier. . Signifie NOTA ; n’est pas relatif à la sécurité. Ce groupe de symboles signifie Mise en garde ! Soyez vigilant ! Il y a des risques de danger reliés aux CHOCS ÉLECTRIQUES, aux PIÈCES EN MOUVEMENT et aux PIÈCES CHAUDES. Reportez-vous aux symboles et aux directives ci-dessous afin de connaître les mesures à prendre pour éviter tout danger. 1-2. Dangers relatifs au soudage à l’arc Y Les symboles présentés ci-après sont utilisés tout au long du présent manuel pour attirer votre attention et identifier les risques de danger. Lorsque vous voyez un symbole, soyez vigilant et suivez les directives mentionnées afin d’éviter tout danger. Les consignes de sécurité présentées ci-après ne font que résumer l’information contenue dans les normes de sécurité énumérées à la section 1-4. Veuillez lire et respecter toutes ces normes de sécurité. D N’utiliser qu’un matériel en bon état. Réparer ou remplacer sur-lechamp les pièces endommagées. Entretenir l’appareil conformément à ce manuel. D Porter un harnais de sécurité quand on travaille en hauteur. D Maintenir solidement en place tous les panneaux et capots. Y L’installation, l’utilisation, l’entretien et les réparations ne doivent être confiés qu’à des personnes qualifiées. D Fixer le câble de retour de façon à obtenir un bon contact métal-métal avec la pièce à souder ou la table de travail, le plus près possible de la soudure. Y Au cours de l’utilisation, tenir toute personne à l’écart et plus particulièrement les enfants. D Isoler la pince de masse quand pas mis à la pièce pour éviter le contact avec tout objet métallique. UN CHOC ÉLECTRIQUE peut tuer. Un simple contact avec des pièces électriques peut provoquer une électrocution ou des blessures graves. L’électrode et le circuit de soudage sont sous tension dès que l’appareil est sur ON. Le circuit d’entrée et les circuits internes de l’appareil sont également sous tension à ce moment-là. En soudage semi-automatique ou automatique, le fil, le dévidoir, le logement des galets d’entraînement et les pièces métalliques en contact avec le fil de soudage sont sous tension. Des matériels mal installés ou mal mis à la terre présentent un danger. Il y a DU COURANT CONTINU IMPORTANT dans les convertisseurs après la suppression de l’alimentation électrique. D Arrêter les convertisseurs, débrancher le courant électrique, et décharger les condensateurs d’alimentation selon les instructions indiquées dans la partie entretien avant de toucher les pièces. D Ne jamais toucher les pièces électriques sous tension. D Porter des gants et des vêtements de protection secs ne comportant pas de trous. D S’isoler de la pièce et de la terre au moyen de tapis ou d’autres moyens isolants suffisamment grands pour empêcher le contact physique éventuel avec la pièce ou la terre. D D D Ne pas se servir de source électrique àcourant électrique dans les zones humides, dans les endroits confinés ou là où on risque de tomber. Se servir d’une source électrique àcourant électrique UNIQUEMENT si le procédé de soudage le demande. Si l’utilisation d’une source électrique àcourant électrique s’avère nécessaire, se servir de la fonction de télécommande si l’appareil en est équipé. D Couper l’alimentation ou arrêter le moteur avant de procéder à l’installation, à la réparation ou à l’entretien de l’appareil. Déverrouiller l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de sécurité). D Installer et mettre à la terre correctement cet appareil conformément à son manuel d’utilisation et aux codes nationaux, provinciaux et municipaux. D Toujours vérifier la terre du cordon d’alimentation − Vérifier et s’assurer que le fil de terre du cordon d’alimentation est bien raccordé à la borne de terre du sectionneur ou que la fiche du cordon est raccordée à une prise correctement mise à la terre. D En effectuant les raccordements d’entrée fixer d’abord le conducteur de mise à la terre approprié et contre-vérifier les connexions. D Vérifier fréquemment le cordon d’alimentation pour voir s’il n’est pas endommagé ou dénudé − remplacer le cordon immédiatement s’il est endommagé − un câble dénudé peut provoquer une électrocution. D Mettre l’appareil hors tension quand on ne l’utilise pas. D Ne pas utiliser des câbles usés, endommagés, de grosseur insuffisante ou mal épissés. D Ne pas enrouler les câbles autour du corps. D Si la pièce soudée doit être mise à la terre, le faire directement avec un câble distinct − ne pas utiliser le connecteur de pièce ou le câble de retour. D Ne pas toucher l’électrode quand on est en contact avec la pièce, la terre ou une électrode provenant d’une autre machine. LES FUMÉES ET LES GAZ peuvent être dangereux. Le soudage génère des fumées et des gaz. Leur inhalation peut être dangereux pour votre santé. D D D D D D D Eloigner votre tête des fumées. Ne pas respirer les fumées. A l’intérieur, ventiler la zone et/ou utiliser un échappement au niveau de l’arc pour l’évacuation des fumées et des gaz de soudage. Si la ventilation est insuffisante, utiliser un respirateur à alimentation d’air homologué. Lire les spécifications de sécurité des matériaux (MSDSs) et les instructions du fabricant concernant les métaux, les consommables, les revêtements, les nettoyants et les dégraisseurs. Travailler dans un espace fermé seulement s’il est bien ventilé ou en portant un respirateur à alimentation d’air. Demander toujours à un surveillant dûment formé de se tenir à proximité. Des fumées et des gaz de soudage peuvent déplacer l’air et abaisser le niveau d’oxygène provoquant des blessures ou des accidents mortels. S’assurer que l’air de respiration ne présente aucun danger. Ne pas souder dans des endroits situés à proximité d’opérations de dégraissage, de nettoyage ou de pulvérisation. La chaleur et les rayons de l’arc peuvent réagir en présence de vapeurs et former des gaz hautement toxiques et irritants. Ne pas souder des métaux munis d’un revêtement, tels que l’acier galvanisé, plaqué en plomb ou au cadmium à moins que le revêtement n’ait été enlevé dans la zone de soudure, que l’endroit soit bien ventilé, et si nécessaire, en portant un respirateur à alimentation d’air. Les revêtements et tous les métaux renfermant ces éléments peuvent dégager des fumées toxiques en cas de soudage. OM-277 Page 5 LES RAYONS DE L’ARC peuvent provoquer des brûlures dans les yeux et sur la peau. Le rayonnement de l’arc du procédé de soudage génère des rayons visibles et invisibles intenses (ultraviolets et infrarouges) susceptibles de provoquer des brûlures dans les yeux et sur la peau. Des étincelles sont projetées pendant le soudage. D Porter un casque de soudage muni d’un écran de filtre approprié pour protéger votre visage et vos yeux pendant le soudage ou pour regarder (voir ANSI Z49.1 et Z87.1 énuméré dans les normes de sécurité). D Porter des protections approuvés pour les oreilles si le niveau sondre est trop élevé. D Utiliser des écrans ou des barrières pour protéger des tiers de l’éclair et de l’éblouissement; demander aux autres personnes de ne pas regarder l’arc. D Porter des vêtements de protection constitué dans une matière durable, résistant au feu (cuir ou laine) et une protection des pieds. LE SOUDAGE peut provoquer un incendie ou une explosion. Le soudage effectué sur des conteneurs fermés tels que des réservoirs, tambours ou des conduites peut provoquer leur éclatement. Des étincelles peuvent être projetées de l’arc de soudure. La projection d’étincelles, des pièces chaudes et des équipements chauds peut provoquer des incendies et des brûlures. Le contact accidentel de l’électrode avec des objets métalliques peut provoquer des étincelles, une explosion, un surchauffement ou un incendie. Avant de commencer le soudage, vérifier et s’assurer que l’endroit ne présente pas de danger. D Se protéger et d’autres personnes de la projection d’étincelles et de métal chaud. D Ne pas souder dans un endroit là où des étincelles peuvent tomber sur des substances inflammables. D Déplacer toutes les substances inflammables à une distance de 10,7 m de l’arc de soudage. En cas d’impossibilité les recouvrir soigneusement avec des protections homologués. D Des étincelles et des matériaux chauds du soudage peuvent facilement passer dans d’autres zones en traversant de petites fissures et des ouvertures. D Surveiller tout déclenchement d’incendie et tenir un extincteur à proximité. D Le soudage effectué sur un plafond, plancher, paroi ou séparation peut déclencher un incendie de l’autre côté. D Ne pas effectuer le soudage sur des conteneurs fermés tels que des réservoirs, tambours, ou conduites, à moins qu’ils n’aient été préparés correctement conformément à AWS F4.1 (voir les normes de sécurité). D Brancher le câble sur la pièce le plus près possible de la zone de soudage pour éviter le transport du courant sur une longue distance par des chemins inconnus éventuels en provoquant des risques d’électrocution et d’incendie. D Ne pas utiliser le poste de soudage pour dégeler des conduites gelées. D En cas de non utilisation, enlever la baguette d’électrode du porteélectrode ou couper le fil à la pointe de contact. D Porter des vêtements de protection dépourvus d’huile tels que des gants en cuir, une chemise en matériau lourd, des pantalons sans revers, des chaussures hautes et un couvre chef. D Avant de souder, retirer toute substance combustible de vos poches telles qu’un allumeur au butane ou des allumettes. DES PARTICULES VOLANTES peuvent blesser les yeux. D Le soudage, l’écaillement, le passage de la pièce à la brosse en fil de fer, et le meulage génèrent des étincelles et des particules métalliques volantes. Pendant la période de refroidissement des soudures, elles risquent de projeter du laitier. D Porter des lunettes de sécurité avec écrans latéraux ou un écran facial. OM-277 Page 6 LES ACCUMULATIONS DE GAZ risquent de provoquer des blessures ou même la mort. Fermer l’alimentation du gaz protecteur en cas de non utilisation. Veiller toujours à bien aérer les espaces confinés ou se servir d’un respirateur d’adduction d’air homologué. D D DES PIÈCES CHAUDES peuvent provoquer des brûlures graves. D Ne pas toucher des parties chaudes à mains nues D Prévoir une période de refroidissement avant d’utiliser le pistolet ou la torche. LES CHAMPS MAGNÉTIQUES peuvent affecter les stimulateurs cardiaques. D D Porteurs de stimulateur cardiaque, restez à distance. Les porteurs d’un stimulateur cardiaque doivent d’abord consulter leur médecin avant de s’approcher des opérations de soudage à l’arc, de gougeage ou de soudage par points. LE BRUIT peut affecter l’ouïe. Le bruit des processus et des équipements peut affecter l’ouïe. D Porter des protections approuvés pour les oreilles si le niveau sondre est trop élevé. Si des BOUTEILLES sont endommagées, elles pourront exploser. Des bouteilles de gaz protecteur contiennent du gaz sous haute pression. Si une bouteille est endommagée, elle peut exploser. Du fait que les bouteilles de gaz font normalement partie du procédé de soudage, les manipuler avec précaution. D Protéger les bouteilles de gaz comprimé d’une chaleur excessive, des chocs mécaniques, du laitier, des flammes ouvertes, des étincelles et des arcs. D Placer les bouteilles debout en les fixant dans un support stationnaire ou dans un porte-bouteilles pour les empêcher de tomber ou de se renverser. D Tenir les bouteilles éloignées des circuits de soudage ou autres circuits électriques. D Ne jamais placer une torche de soudage sur une bouteille à gaz. D Une électrode de soudage ne doit jamais entrer en contact avec une bouteille. D Ne jamais souder une bouteille pressurisée − risque d’explosion. D Utiliser seulement des bouteilles de gaz protecteur, régulateurs, tuyaux et raccords convenables pour cette application spécifique; les maintenir ainsi que les éléments associés en bon état. D Ne pas tenir la tête en face de la sortie en ouvrant la soupape de la bouteille. D Maintenir le chapeau de protection sur la soupape, sauf en cas d’utilisation ou de branchement de la bouteille. D Lire et suivre les instructions concernant les bouteilles de gaz comprimé, les équipements associés et les publications P-1 CGA énumérées dans les normes de sécurité. 1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance Risque D’INCENDIE OU D’EXPLOSION. DES ORGANES MOBILES peuvent provoquer des blessures. D Ne pas placer l’appareil sur, au-dessus ou à proximité de surfaces infllammables. D Rester à l’écart des organes mobiles comme le ventilateur. D Maintenir fermés et fixement en place les portes, panneaux, recouvrements et dispositifs de protection. D Ne pas installer l’appareil à proximité de produits inflammables D Ne pas surcharger l’installation électrique − s”assurer que l’alimentation est correctement dimensionné et protégé avant de mettre l’appareil en service. LE RAYONNEMENT HAUTE FRÉQUENCE (H.F.) risque de provoquer des interférences. LA CHUTE DE L’APPAREIL peut blesser. D Utiliser l’anneau de levage uniquement pour soulever l’appareil, NON PAS les chariot, les bouteilles de gaz ou tout autre accessoire. D Utiliser un engin d’une capacité appropriée pour soulever l’appareil. D En utilisant des fourches de levage pour déplacer l’unité, s’assurer que les fourches sont suffisamment longues pour dépasser du côté opposé de l’appareil. L’EMPLOI EXCESSIF peut SURCHAUFFER L’ÉQUIPEMENT. D D D D D D Prévoir une période de refroidissement, respecter le cycle opératoire nominal. D Réduire le courant ou le cycle opératoire avant de recommancer le soudage. LE SOUDAGE À L’ARC risque de provoquer des interférences. D Ne pas obstruer les passages d’air du poste. LES CHARGES ÉLECTROSTATIQUES peuvent endommager les circuits imprimés. D Établir la connexion avec la barrette de terre avant de manipuler des cartes ou des pièces. D Utiliser des pochettes et des boîtes antistatiques pour stocker, déplacer ou expédier des cartes de circuits imprimes. DES ORGANES MOBILES peuvent provoquer des blessures. D Ne pas s’approcher des organes mobiles. D Ne pas s’approcher des points de coincement tels que des rouleaux de commande. LES FILS DE SOUDAGE peuvent provoquer des blessures. D Ne pas appuyer sur la gachette avant d’en avoir reçu l’instruction. D Ne pas diriger le pistolet vers soi, d’autres personnes ou toute pièce mécanique en engageant le fil de soudage. D Le rayonnement haute frequence peut provoquer des interférences avec les équipements de radio−navigation et de communication, les services de sécurité et les ordinateurs. Demander seulement à des personnes qualifiées familiarisées avec des équipements électroniques de faire fonctionner l’installation. L’utilisateur est tenu de faire corriger rapidement par un électricien qualifié les interférences résultant de l’installation. Si le FCC signale des interférences, arrêter immédiatement l’appareil. Effectuer régulièrement le contrôle et l’entretien de l’installation. Maintenir soigneusement fermés les portes et les panneaux des sources de haute fréquence, maintenir les éclateurs à une distance correcte et utiliser une terre et et un blindage pour réduire les interférences éventuelles. D D D D D D L’énergie électromagnétique risque de provoquer des interférences pour l’équipement électronique sensible tel que les ordinateurs et l’équipement commandé par ordinateur tel que les robots. Veiller à ce que tout l’équipement de la zone de soudage soit compatible électromagnétiquement. Pour réduire la possibilité d’interférence, maintenir les câbles de soudage aussi courts que possible, les grouper, et les poser aussi bas que possible (ex. par terre). Veiller à souder à une distance de 100 mètres de tout équipement électronique sensible. Veiller à ce que ce poste de soudage soit posé et mis à la terre conformément à ce mode d’emploi. En cas d’interférences après avoir pris les mesures précédentes, il incombe à l’utilisateur de prendre des mesures supplémentaires telles que le déplacement du poste, l’utilisation de câbles blindés, l’utilisation de filtres de ligne ou la pose de protecteurs dans la zone de travail. LES CHAMPS MAGNÉTIQUES peuvent affecter les stimulateurs cardiaques. D Porteurs de stimulateur cardiaque, restez à distance. D Les porteurs d’un stimulateur cardiaque doivent d’abord consulter leur médecin avant de s’approcher des opérations de soudage à l’arc, de gougeage ou de soudage par points. OM-277 Page 7 1-4. Principales normes de sécurité Safety in Welding and Cutting, norme ANSI Z49.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL 33126 Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent of Documents, U.S. Government Printing Office, Washington, D.C. 20402. Recommended Safe Practice for the Preparation for Welding and Cutting of Containers That Have Held Hazardous Substances, norme AWS F4.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL 33126 National Electrical Code, NFPA Standard 70, de la National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, de la Compressed Gas Association, 1235 Jefferson Davis Highway, Suite 501, Arlington, VA 22202. Règles de sécurité en soudage, coupage et procédés connexes, norme CSA W117.2, de l’Association canadienne de normalisation, vente de normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3. Safe Practices For Occupation And Educational Eye And Face Protection, norme ANSI Z87.1, de l’American National Standards Institute, 1430 Broadway, New York, NY 10018. Cutting and Welding Processes, norme NFPA 51B, de la National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. 1-5. Information sur les champs électromagnétiques Données sur le soudage électrique et sur les effets, pour l’organisme, des champs magnétiques basse fréquence Afin de réduire les champs électromagnétiques dans l’environnement de travail, respecter les consignes suivantes : L’extrait suivant est tiré des conclusions générales du document intitulé Biological Effects of Power Frequency Electric & Magnetic Fields − Background Paper, OTA−BP−E−53 (Washington DC : U.S. Government Printing Office, mai 1989), publié par le Office of Technology Assessment du Congrès américain : «... il existe maintenant d’abondantes données scientifiques compilées à la suite d’expériences sur la cellule ou d’études sur des animaux et des humains, qui montrent clairement que les champs électromagnétiques basse fréquence peuvent avoir des effets sur l’organisme et même y produire des transformations. Même s’il s’agit de travaux de très grande qualité, les résultats sont complexes. Cette démarche scientifique ne nous permet pas d’établir un tableau d’ensemble cohérent. Pire encore, elle ne nous permet pas de tirer des conclusions finales concernant les risques éventuels, ni d’offrir des conseils sur les mesures à prendre pour réduire sinon éliminer les risques éventuels». (Traduction libre) 1 OM-277 Page 8 2 3 4 5 Garder les câbles ensembles en les torsadant ou en les attachant avec du ruban adhésif. Mettre tous les câbles du côté opposé de l’opérateur. Ne pas courber pas et ne pas entourer pas les câbles autour de vous. Garder le poste de soudage et les câbles le plus loin possible de vous. Relier la pince de masse le plus près possible de la zone de soudure. Consignes relatives aux stimulateurs cardiaques : Les consignes mentionnées précédemment font partie de celles destinées aux personnes ayant recours à un stimulateur cardiaque. Veuillez consulter votre médecin pour obtenir plus de détails. SECTION 2 − DEFINITIONS 2-1. General Precautionary Label 1/96 Warning! Watch Out! There are possible hazards as shown by the symbols. 1 1.1 1.2 1.3 1 1.1 1.3 1.2 2 2.1 2.2 2 2.1 2.2 2.3 2.3 3 3.1 3.2 3 3.1 3.2 3.3 3.3 4 4 4.1 4.1 + + + 5 5 + 6 6 Electric shock from welding electrode or wiring can kill. Wear dry insulating gloves. Do not touch electrode with bare hand. Do not wear wet or damaged gloves. Protect yourself from electric shock by insulating yourself from work and ground. Disconnect input plug or power before working on machine. Breathing welding fumes can be hazardous to your health. Keep your head out of the fumes. Use forced ventilation or local exhaust to remove the fumes. Use ventilating fan to remove fumes. Welding sparks can cause explosion or fire. Keep flammables away from welding. Do not weld near flammables. Welding sparks can cause fires. Have a fire extinguisher nearby, and have a watchperson ready to use it. Do not weld on drums or any closed containers. Arc rays can burn eyes and injure skin. Wear hat and safety glasses. Use ear protection and button shirt collar. Use welding helmet with correct shade of filter. Wear complete body protection. Become trained and read the instructions before working on the machine or welding. Do not remove or paint over (cover) the label. S-176 254-A OM-277 Page 9 2-2. Input Connection Label 1 1/96 2 3 4 1 Warning! Watch Out! There are possible hazards as shown by the symbols. Electric shock from wiring can kill. Disconnect input plug or power before working on machine. Read the Owner’s Manual before working on this machine. Consult rating label for input power requirements, and check power available at the job site − they must match. Read Owner’s Manual and inside labels for connection points and procedures. Move jumper links as shown on inside label to match voltage at job site. Having a loop of extra length, connect grounding conductor first. Connect line input conductors as shown on inside label − double-check all connections, jumper link positions, and input voltage before applying power. 2 3 4 1 2 ? V ? A 3 ? 5 V 6 ÍÍÍÍ ÍÍÍÍ ÍÍÍÍ ÍÍ ÍÍ 5 7 5 3 8 4 S-179 290 6 7 8 9 9 2-3. Electric Shock And Airflow Label 1 2 1 3 2 3 S-179 563 Warning! Watch Out! There are possible hazards as shown by the symbols. Electric shock from wiring and exposed weld terminals can kill. Close door before turning on unit. 1/96 2-4. Nameplate Safety Symbols 1 1 1 2 3 4 5 2 3 4 5 6 6 Warning! Watch Out! There are possible hazards as shown by the symbols. Electric shock from welding electrode or wiring can kill. Sparks from arcing electrode can cause explosion or fire − disconnect cable for process not in use. Read Owner’s Manual for connection procedures. Electric shock from wiring can kill. Disconnect input power before working on unit or making terminal strip connections. Nameplate D-179 389 OM-277 Page 10 2-5. Manufacturer’s Rating Labels For CE Products Match label to one on unit. See Section 3-4. 2-6. Symbols And Definitions NOTE A U0 I1 IP S Some symbols are found only on CE products. Amperes Amperage/Voltage Control−Panel Gas Tungsten Arc Welding (GTAW) Shielded Metal Arc Welding (SMAW) Temperature Do Not Switch While Welding Arc Force (DIG) Gas Metal Arc Welding (GMAW) Output Circuit Breaker Remote Protective Earth (Ground) Positive Weld Output Terminal Negative Weld Output Terminal Input On Off Percent Direct Current Conventional Load Voltage Line Connection Duty Cycle Three-Phase Transformer Rectifier Rated No Load Voltage (Average) Primary Current U1 I2 Primary Voltage Rated Welding Current Degree Of Protection Three-Phase Suitable For Areas Of Increased Shock Hazard Wire Feeder U2 X S1 KVA V Hz Volts Hertz OM-277 Page 11 SECTION 3 − INSTALLATION 3-1. Specifications Model 300 Amp 450 Amp IP Rating Rated Welding Output 21M 300 A @ 32 (29) Volts DC, 100% Duty Cycle 21M 450 A @ 38 (36.5) Volts DC, 100% Duty Cycle Amperage/ Voltage Range Max OCV−DC 15 − 375A In CC Mode Amperes Input at Rated Load Output 50 or 60 Hz, Three-Phase 200 V 230 V 380 V 400 V 440 V 460 V 520 V 575 V KVA KW 60 VDC In CC Mode 57.5 4.0* 50 3.5* 30 1.5* 28 1.4* 26 1.3* 25 1.8* -- 20 1.4* 20 1.4* 12.9 0.6* 10 − 32V In CV Mode 38 (40) VDC In CV Mode 69 4.0* 60 3.5* 36 1.4* 34 1.3* 31 1.2* 30 1.8* -- 24 1.4* 23.7 1.4* 13.4 0.6* 20 − 565A In CC Mode 65 (62) VDC In CC Mode 91 4.2* 79 3.8* 48 1.8* 46 1.6* 41 1.4* 39 1.9* 38 1.4* 31 1.5* 31.4 1.5* 22 0.7* 10 − 38V In CV Mode 45 (50) VDC In CV Mode 104 4.2* 90 3.8* 52.5 1.6* 51 1.4* 46 1.3* 45 1.9* 34 1.2* 36 1.5* 35.3 1.5* 22.3 0.7* *While idling ( ) Indicates specification differences for CE models 3-2. Duty Cycle And Overheating Duty Cycle is percentage of 10 minutes that unit can weld at rated load without overheating. If unit overheats, thermostat(s) opens, output stops, and cooling fan runs. Wait fifteen minutes for unit to cool. Reduce amperage or duty cycle before welding. Y Exceeding duty cycle can damage unit and void warranty. 100% Duty Cycle Continuous Welding Overheating A/V 0 15 Minutes OR Reduce Duty Cycle duty1 4/95 / Ref. SA-168 918 OM-277 Page 12 3-3. Volt-Ampere Curves Volt-ampere curves show minimum and maximum voltage and amperage output capabilities of unit. Curves of other settings fall between curves shown. 300 Amp 450 Amp A. CC Mode A. CC Mode B. CV Mode B. CV Mode va_curve1 − 4/95 − ST-168 912 / ST-168 913 / ST-168 914 / ST-168 915 OM-277 Page 13 3-4. Selecting A Location 1 2 Lifting Eye Lifting Forks Use lifting eye or lifting forks to move unit. Movement If using lifting forks, extend forks beyond opposite side of unit. 1 3 Rating Label (Non CE Models Only) Use rating label to determine input power needs. Label located under front access door. OR 2 4 Plate Label (CE Models Only) Label located under front access door. 5 6 Location Rating Label (CE Models Only) Use rating label to determine input power needs. Label located on rear access door (see Section 2-5). 3 6 Line Disconnect Device Locate unit near correct input power supply. 18 in (460 mm) Y Special installation may be required where gasoline or volatile liquids are present − see NEC Article 511 or CEC Section 20. 4 5 18 in (460 mm) 3-5. Dimensions And Weights Dimensions Height 27-1/4 in (692 mm) E Width 22-1/4 in (565 mm) 4 Holes Depth* 35-3/4 in (908 mm) A** 35 in (889 mm) B*** 1-1/4 in (32 mm) C 21 in (533 mm) D 1-3/16 in (30 mm) E 7/16 in (11 mm) Dia C D A *300 Amp Model = 28-1/4 in (718 mm) **300 Amp Model = 27-1/2 in (699 mm) ***300 Amp Model = 3/4 in (19 mm) Weight B OM-277 Page 14 Ref. ST-153 556-A 300 Amp 361 lbs (164 kg) 450 Amp 424 lbs (192 kg) 3-6. Tipping Y Be careful when placing or moving unit over uneven surfaces. 3-7. 115 VAC Receptacle And Circuit Breakers Y Turn Off power before connecting to receptacle. 1 115 V 15 A AC Receptacle RC9 Power is shared between RC9 and Remote 14 receptacle RC8 or terminal strip 1T (see Section 3-10). 3 2 2 3 Circuit Breaker CB1 Circuit Breaker CB2 CB1 protects 115 volts ac portion of RC8, 1T, and RC9 from overload. CB2 protects 24 volts ac portion of RC8 and 1T from overload. Press button to reset breaker. 1 Ref. ST-800 166-B OM-277 Page 15 3-8. Weld Output Terminals And Selecting Cable Sizes Total Cable (Copper) Length In Weld Circuit Not Exceeding 100 ft (30 m) Or Less Turn Off power before connecting to weld output terminals. Negative Positive CC Terminal Positive CV Terminal 150 ft (45 m) 200 ft (60 m) 250 ft (70 m) 300 ft (90 m) 350 ft (105 m) 400 ft (120 m) Welding Amperes 10 − 60% Duty Cycle 60 − 100% Duty Cycle 100 4 4 4 3 2 1 1/0 1/0 150 3 3 2 1 1/0 2/0 3/0 3/0 200 3 2 1 1/0 2/0 3/0 4/0 4/0 250 2 1 1/0 2/0 3/0 4/0 2-2/0 2-2/0 300 1 1/0 2/0 3/0 4/0 2-2/0 2-3/0 2-3/0 350 1/0 2/0 3/0 4/0 2-2/0 2-3/0 2-3/0 2-4/0 400 1/0 2/0 3/0 4/0 2-2/0 2-3/0 2-4/0 2-4/0 500 2/0 3/0 4/0 2-2/0 2-3/0 2-4/0 3-3/0 3-3/0 600 3/0 4/0 2-2/0 2-3/0 2-4/0 3-3/0 3-4/0 3-4/0 700 4/0 2-2/0 2-3/0 2-4/0 3-3/0 3-4/0 3-4/0 4-4/0 10 − 100% Duty Cycle *Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. Contact your distributor for the mm2 equivalent weld cable sizes. S-0007-E 3-9. Remote 14 Receptacle And Terminal Strip 1T Information 24 VOLTS AC REMOTE OUTPUT CONTROL 115 VOLTS AC GND REMOTE POWER ON/OFF REMOTE VOLTAGE SENSING * Not Used OM-277 Page 16 Socket Terminal Information A A 24 volts ac. Protected by circuit breaker CB2. B B Contact closure to A completes 24 volts ac contactor control circuit. C C Command reference; 0 to +10 volts dc (CC), +10 volts dc (CV). D D Remote control circuit common. E E 0 to +10 volts dc input command signal from remote control. F * Current feedback; 0 to +10 volts dc, 1 volt per 100 amperes. H * Voltage feedback; 0 to +10 volts dc, 1 volt per 10 arc volts. I I 115 volts, 15 amperes, 60 Hz ac. Protected by circuit breaker CB1. J J Contact closure to I completes 115 volts ac contactor control circuit. K K Chassis common. G * Circuit common for 24 and 115 volts ac circuits. * L * M * N Voltage sensing signal from Negative (-) weld output terminal. * P Voltage sensing signal from Positive (+) weld output terminal. To remote On/Off switch. switch 3-10. Connecting Remote Control 1 Remote 14 Receptacle RC8 Connect remote control to RC8. If plug does not fit, wire cord to terminal strip 1T. Y Turn Off power before opening terminal strip cover. OR 2 3 4 OR Terminal Strip 1T Remote Control Cord Strain Relief (Customer Supplied) Secure cord in strain relief. Reinstall and secure access panel. Close door. 1 A B J K I H C L N M D G E F 3 2 4 C E REMOTE OUTPUT CONTROL D I J A B N P 115 VAC 24VAC REMOTE REMOTE REMOTE VOLTAGE CONTACTOR CONTACTOR SENSE K GND M L REMOTE POWER ON/OFF S-162 895-B Ref. ST-800 170-E / Ref. S-0004-A / S-0750 OM-277 Page 17 3-11. Electrical Service Guide 60 Hertz Models 300 Amp Model 450 Amp Model Input Voltage 200 230 460 575 200 230 460 575 Input Amperes At Rated Output 69 60 30 24 104 90 45 36 Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes 100 90 45 35 150 125 70 50 4 6 10 10 2 3 8 8 195 (59) 176 (54) 318 (97) 496 (151) 173 (53) 191 (58) 287 (87) 448 (137) 8 8 10 10 6 6 8 10 Min Input Conductor Size In AWG/Kcmil Max Recommended Input Conductor Length In Feet (Meters) Min Grounding Conductor Size In AWG/Kcmil Reference: 1996 National Electrical Code (NEC) 50 Hertz Models 300 Amp Model 450 Amp Model Input Voltage 380 400 440 380 400 440 520 Input Amperes At Rated Output 36 34 31 52.5 51 46 34 Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes 50 50 45 80 80 70 60 Min Input Conductor Size In AWG/Kcmil 8 8 8 6 6 8 8 320 (98) 355 (108) 429 (131) 296 (90) 328 (100) 262 (80) 366 (112) 10 10 10 8 8 8 10 Max Recommended Input Conductor Length In Feet (Meters) Min Grounding Conductor Size In AWG/Kcmil Reference: 1996 National Electrical Code (NEC) OM-277 Page 18 3-12. Placing Jumper Links Check input voltage available at site. 1 Jumper Link Label Check label − only one is on unit. 2 Jumper Links Move jumper links to match input voltage. Close access door, or go on to Section 3-13. 200 VOLTS 230 VOLTS 460 VOLTS Ref. S-174 976-A 230 VOLTS 460 VOLTS 575 VOLTS Ref. S-174 973-A 1 220 VOLTS 380 VOLTS 400 VOLTS 440 VOLTS (FACTORY OPTION) 380 VOLTS Ref. S-174 975-A 520 VOLTS 2 Ref. S-177 159 Tools Needed: 3/8 in 3/8 in Do not overtighten jumper link nuts. Ref. ST-800 103-A OM-277 Page 19 3-13. Connecting Input Power 1 Tools Needed: Input And Grounding Conductors See Section 3-11. 3/8 in 3/8 in 2 Line Disconnect Device See Section 3-11. 3 4 Reed Switch (Ground Current Sensor) (Optional) Grounding Conductor If unit is equipped with optional ground current sensor, route grounding conductor through reed switch two times and connect to ground terminal. 2 Close access door. L1 (U) L2 (V) L3 (W) Connect GND/PE Conductor First. 1 IMPORTANT 3 Input Contactor 4 L1 (U) L2 (V) L3 (W) 3 GND/ PE Connect GND/PE Conductor First. ST-800 103-A / Ref. ST-801 116 OM-277 Page 20 SECTION 4 − OPERATION 4-1. Controls (Non CE Models) 450 Amp Model Shown 1 2 9 3 4 5 8 7 6 Ref. ST-184 940 1 2 Process Selector Switch Arc Force (Dig) Control Control increases SMAW short-circuit amperage which allows the operator to use a very short arc length without sticking the electrode. Set control at 0 for normal welding amperage. Turn clockwise to increase short-circuit amperage. 3 Hot Start Switch Turn switch On for SMAW, SAW, and CAC-A. Turn Off for GTAW welding. When set in On position, higher short-circuit amperage helps arc starting. After arc starts, the Amperage/Voltage control setting determines weld amperage. 4 Amperage/Voltage Adjustment Control When Process Selector switch is in the SMAW/GTAW position, turn control clockwise to increase amperage. Read amperage from outer scale of control. When Process Selector switch is in the GMAW position, turn control clockwise to increase voltage. Voltmeter value changes as control knob is turned. Control can be adjusted while welding. 5 Digital Meters With Process Selector switch in the SMAW/ GTAW position, digital meters will read 0 (zero) with contactor off. Digital meters will display actual output voltage and amperage with contactor on. With Process Selector switch in the GMAW position, voltmeter displays preset voltage with contactor off. Voltmeter and ammeter display actual output voltage and amperage with contactor on. 6 Power Switch With Indicator Light 7 High Temperature Shutdown Light 8 Remote Amperage/Voltage Control Switch For front panel control, place switch in Panel position. For remote control, place switch in Remote position, and connect remote device (see Section 3-10). 9 Output Switch (Contactor) For front panel control of output, place switch in Panel position. For remote control of output, place switch in Remote position, and connect remote device (see Section 3-10). Y Weld output studs are energized only when Output switch is in On position, or while welding. Y Turn Off power before connecting to remote device. OM-277 Page 21 4-2. Controls (CE Models) 300 Amp Model Shown 1 2 9 3 4 5 8 7 6 Ref. ST-184 938 1 2 Process Selector Switch Arc Force (Dig) Control Control increases SMAW short-circuit amperage which allows the operator to use a very short arc length without sticking the electrode. Set control at 0 for normal welding amperage. Turn clockwise to increase short-circuit amperage. 3 Hot Start Switch Turn switch On for SMAW, SAW, and CAC-A. Turn Off for GTAW welding. When set in On position, higher short-circuit amperage helps arc starting. After arc starts, the Amperage/Voltage control setting determines weld amperage. 4 Amperage/Voltage Adjustment Control When Process Selector switch is in the OM-277 Page 22 SMAW/GTAW position, turn control clockwise to increase amperage. Read amperage from outer scale of control. When Process Selector switch is in the GMAW position, turn control clockwise to increase voltage. Voltmeter value changes as control knob is turned. Control can be adjusted while welding. 5 Digital Meters With Process Selector switch in the SMAW/ GTAW position, digital meters will read 0 (zero) with contactor off. Digital meters will display actual output voltage and amperage with contactor on. With Process Selector switch in the GMAW position, voltmeter displays preset voltage with contactor off. Voltmeter and ammeter display actual output voltage and amperage with contactor on. 6 Power Switch With Indicator Light 7 High Temperature Shutdown Light 8 Remote Amperage/Voltage Control Switch For front panel control, place switch in Panel position. For remote control, place switch in Remote position, and connect remote device (see Section 3-10). 9 Output Switch (Contactor) For front panel control of output, place switch in Panel position. For remote control of output, place switch in Remote position, and connect remote device (see Section 3-10). Y Weld output studs are energized only when Output switch is in On position, or while welding. Y Turn Off power before connecting to remote device. SECTION 5 − MAINTENANCE & TROUBLESHOOTING 5-1. Routine Maintenance Y Disconnect power before maintaining. 3 Months Repair or replace cracked weld cable. Replace unreadable labels. Clean and tighten weld terminals. 6 Months Blow out or vacuum inside. During heavy service, clean monthly. OR 5-2. Fuse F1 Y Turn Off power before opening rear access door. 1 Fuse F1 (See Parts List For Rating) Fuse F1 protects control transformer from overload. If F1 opens, weld output and fan motor stops. Replace F1. 1 Tools Needed: 3/8 in Ref. ST-800 101-C OM-277 Page 23 5-3. Troubleshooting Trouble No weld output; unit completely inoperative; pilot light PL1 off. Remedy Place line disconnect device in On position (see Section 3-13). Check for open line fuse(s), and replace if open (see Section 3-13). Check for proper input power connections (see Section 3-13). Check for proper jumper link position (see Section 3-12). Check fuse F1, and replace if necessary (see Section 5-2). No weld output; pilot light PL1 on. Unit overheated. Allow unit to cool with fan On (see Section 3-2). If using remote control, place Output (Contactor) switch in Remote 14 position, and connect remote control (see Sections 3-9 and 3-10). If remote is not being used, place switch in On position (see Section 4-2). Check, repair, or replace remote control. Limited weld output and low open-circuit voltage. Check position of Remote Amperage/Voltage Control switch (see Section 4-2). Check for open line fuse(s), and replace if open (see Section 3-13). Check for proper input power connections (see Section 3-13). Check for proper jumper link position (see Section 3-12). Clean and tighten all weld output connections. Unit provides only maximum or minimum weld output. Have Factory Authorized Service Agent check control board PC1 and hall device HD1. Check position of Remote Amperage/Voltage Control switch (see Section 4-2). Erratic or improper weld output. Use proper size and type of weld cable (see Section 3-8). Clean and tighten all weld connections. Check wire feeder installation according to Owner’s Manual. Check position of Process selector switch (see Section 4-2). Have Factory Authorized Service Agent check control board PC1 and hall device HD1. No 115 volts ac output at duplex receptacle, Remote 14 receptacle, or terminal strip 1T. Reset circuit breaker CB1 (see Section 3-7). No 24 volts ac output at Remote 14 receptacle or terminal strip 1T. Reset circuit breaker CB2 (see Section 3-7). Fan not operating. Note: fan only runs when cooling is necessary. Check for and remove anything blocking fan movement. Have Factory Authorized Service Agent check fan motor. Wandering arc; poor control of arc direction. Reduce gas flow rate. Select proper size tungsten. Properly prepare tungsten. Tungsten electrode oxidizing and not remaining bright after conclusion of weld. Shield weld zone from drafts. Increase postflow time. Check and tighten all gas fittings. Properly prepare tungsten. Check for water in torch, and repair torch if necessary. See torch Owner’s Manual. Digital meter not working properly. OM-277 Page 24 Have Factory Authorized Service Agent check control board PC1 and connections, and replace if necessary. SECTION 6 − ELECTRICAL DIAGRAM For Primary Circuit Diagram Portion, refer to Circuit Diagram located inside wrapper of welding power source. SC-188 089 Figure 6-1. Circuit Diagram OM-277 Page 25 SECTION 7 − PARTS LIST 20 15 4 11 24 28 Fig 7-3 & 7-4 22 31 30 Fig 7-2 29 3 2 1 27 4 26 25 5 23 6 7 8 10 12 13 9 14 16 17 3 19 18 Fig 7-5 not available unless listed. 21 22 . Hardware is common and ST-800 704-B Figure 7-1. Main Assembly OM-277 Page 26 Quantity Item No. Dia. Mkgs. Part No. Model Description 302 452 Figure 7-1. Main Assembly . . . 1 . . . . . . . . . . . . . . +179 430 . . . 1 . . . . . . . . . . . . . . +179 432 . . . 2 . . . . . . . . . . . . . . . 179 429 . . . 2 . . . . . . . . . . . . . . . 179 431 . . . 3 . . . . . . . . . . . . . . . 164 699 . . . 4 . . . . . . . . . . . . . . . 162 816 . . . 5 . . . . . . . . . . . . . . . 162 820 . . . 6 . . . . . . . . . . . . . . . 162 830 . . . . . . . . . . . . . . . . . . . . . 604 536 . . . 7 . . . . . . . . . . . . . . . 177 279 . . . 8 . . . . . C1 . . . . . . 182 661 . . . . . . . . . . . . . . . . . . . . . 163 535 . . . . . . . . . . . R6 . . . . . . 140 002 . . . . . . . . . . . . . . . . . . . . . 162 817 . . . . . . . . . . . . . . . . . . . . . 162 799 . . . . . . . . . . . . . . . . . . . . . 182 660 . . . 9 . . . . . . . . . . . . . . . 173 605 . . . 10 . . . . . HD1 . . . . . 168 829 . . . . . . . . . PLG14 . . . . 115 094 . . . 11 . . . . . Z1 . . . . . . 163 222 . . . 11 . . . . . Z1 . . . . . . 163 221 . . . 12 . . . C21-23 . . . . 163 906 . . . 12 . . . C21-23 . . . . 179 904 . . . 13 . . . . . T2 . . . . . . 159 042 . . . 13 . . . . . T2 . . . . . . 159 041 . . . 13 . . . . . T2 . . . . . . 159 043 . . . 14 . . . . . TE1 . . . . . 159 244 . . . 15 . . . . . . . . . . . . . . . 601 835 . . . 16 . . . . . . . . . . . . . . . 038 887 . . . . . . . . . . . . . . . . . . . . . 010 913 . . . . . . . . . . . . . . . . . . . . . 601 835 . . . . . . . . . . . . . . . . . . . . . 038 618 . . . 17 . . . . . . . . . . . . . . . 159 034 . . . 18 . . . . . . . . . . . . . . . . Fig 7-5 . . . 19 . . . . . F1 . . . . . *156 065 . . . 20 . . . . . . W . . . . . . 160 760 . . . 20 . . . . . . W . . . . . . 160 793 . . . 21 . . . . . CR4 . . . ♦140 750 . . . 22 . . . . . . . . . . . . . . . 134 464 . . . 23 . . . . . . . . . . . . . . . 163 533 . . . 23 . . . . . . . . . . . . . . . 163 359 . . . 24 . . . . . T1 . . . . . . 189 840 . . . 25 . . . . . . . . . . . . . . . 163 067 . . . 26 . . . . . . . . . . . . . . . 163 066 . . . 24 . . . . . T1 . . . . . . 189 841 . . . 25 . . . . . . . . . . . . . . . 169 015 . . . 26 . . . . . . . . . . . . . . . 169 014 . . . 24 . . . . . T1 . . . . . . 189 843 . . . 25 . . . . . . . . . . . . . . . 161 888 . . . 26 . . . . . . . . . . . . . . . 161 887 . . . 24 . . . . . T1 . . . . . . 189 844 . . . 25 . . . . . . . . . . . . . . . 179 435 . . . 26 . . . . . . . . . . . . . . . 179 436 . . . 24 . . . . . T1 . . . . . . 189 842 . . . 25 . . . . . . . . . . . . . . . 172 351 . . . 26 . . . . . . . . . . . . . . . 172 350 . . . 24 . . . . . T1 . . . . . . 189 845 . . . 25 . . . . . . . . . . . . . . . 179 214 . . PANEL, side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . PANEL, side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . COVER, top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . COVER, top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . BAFFLE, air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2 . . CHANNEL, upright . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 . . . . 4 . . BAR, mtg lift eye . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2 . . LIFT EYE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . SCREW, .312-18 x 1.75 hexhd-pln gr5 . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2 . . GASKET, lift eye . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . CAPACITOR ASSEMBLY, (consisting of) . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . CAPACITOR, elctlt 16000uf 60VDC . . . . . . . . . . . . . . . . . . . . . . . 6 . . . . 6 . . . . RESISTOR, WW fxd 10W 500 ohm . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . BUS BAR, capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2 . . BRACKET, mtg capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . BRACKET, mtg capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 . . BRACKET, mtg LEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . TRANSDUCER, current 300A module . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . STABILIZER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . STABILIZER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . CAPACITOR, (60Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 . . . . 3 . . CAPACITOR, (50Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 . . . . 3 . . TRANSFORMER, control 50VA 24V 230/460/575 (60Hz) . . . . . . . 1 . . . . 1 . . TRANSFORMER, control 50VA 24V 200/230/460 (60Hz) . . . . . . . . . . . . . 1 . . TRANSFORMER, control 50VA 24V (50Hz) . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . PRIMARY BOX, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . NUT, 10-32 brs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 . . . 24 . . . . STUD, pri bd brs 10-32 x 1.375 . . . . . . . . . . . . . . . . . . . . . . . . . . 24 . . . 24 . . WASHER, flat .218 ID brs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 . . . 24 . . NUT, 10-32 brs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 . . . 24 . . LINK, jumper term bd pri . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 . . . . 8 . . HOLDER, fuse mintr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . PANEL, rear w/components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . FUSE, crtg .5A 600V time delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . CONTACTOR, def prp 40A 3P 24VAC . . . . . . . . . . . . . . . . . . . . . . . 1 . . CONTACTOR, def prp 60A 3P 24VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . SWITCH, reed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . LABEL, warning general precautionary . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2 . . BASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . BASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . TRANSFORMER, pwr main 200/230/460 (consisting of) . . . . . . . 1 . . . . COIL, pri/sec 200/230/460 (center & RH) . . . . . . . . . . . . . . . . . . . 2 . . . . COIL, pri/sec 200/230/460 (LH) . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . TRANSFORMER, pwr main 230/460/575 (consisting of) . . . . . . . 1 . . . . COIL, pri/sec 230/460/575 (center & RH) . . . . . . . . . . . . . . . . . . . 2 . . . . COIL, pri/sec 230/460/575 (LH) . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . TRANSFORMER, pwr main 200/230/460 (consisting of) . . . . . . . . . . . . . 1 . . . . COIL, pri/sec 200/230/460 (center & RH) . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . COIL, pri/sec 200/230/460 (LH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . TRANSFORMER, pwr main 230/460/575 (consisting of) . . . . . . . . . . . . . 1 . . . . COIL, pri/sec 230/460/575 (center & RH) . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . COIL, pri/sec 230/460/575 (LH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . TRANSFORMER, pwr main 380/400/440 (consisting of) . . . . . . . 1 . . . . COIL, pri/sec (center & RH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . COIL, pri/sec (LH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . TRANSFORMER, pwr main 380/400/440 (consisting of) . . . . . . . . . . . . . 1 . . . . COIL, pri/sec (center & RH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 OM-277 Page 27 Quantity Item No. Dia. Mkgs. Model Part No. Description 302 452 Figure 7-1. Main Assembly (Continued) . . . 26 . . . . . . . . . . . . . . . 179 213 . . . . COIL, pri/sec (LH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 24 . . . . . T1 . . . . . . 189 846 . . TRANSFORMER, pwr main 380/520 (consisting of) . . . . . . . . . . . . . . . . . 1 . . . 25 . . . . . . . . . . . . . . . 179 210 . . . . COIL, pri/sec LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 26 . . . . . . . . . . . . . . . 179 211 . . . . COIL, pri/sec center & RH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . . . . . . . TP1,2 . . . . 175 405 . . THERMOSTAT, NC (Included w/T1) . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2 . . . . . . . . . . TP4,5 . . . . 168 891 . . THERMOSTAT, NC (Included w/T1) . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2 . . . . . . . . . . PLG6 . . . . 168 847 . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . . . . . . . . RC6 . . . . . 168 845 . . CONNECTOR & PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . . . . . . PLG13 . . . . 189 873 . . CONNECTOR & PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . . . . . . . RC13 . . . . 169 241 . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 27 . . . . . . . . . . . . . . . 144 468 . . STRIP, polyest gl lam .062 x 2.375 x 3.500 . . . . . . . . . . . . . . . . . . . 3 . . . . 3 . . . 28 . . . . . . . . . . . . . . . 605 538 . . CABLE TIE, 0-4.500 bundle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 . . . . 3 . . . 29 . . . . . . . . . . . . . . . 161 294 . . BRACKET, mtg rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2 . . . 30 . . . . . . . . . . . . . . . . Fig 7-2 . . PANEL, front w/components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 31 . . . . . SR1 . . . . . 175 070 . . RECTIFIER, si diode (Fig 7-3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 31 . . . . . SR1 . . . . . 175 071 . . RECTIFIER, si diode (Fig 7-4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . PLG7 . . . . 152 249 . . CONNECTOR & PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . . . . . . . . RC7 . . . . . 168 846 . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . . . . . . . . . . . . . . . . . . 010 467 . . CONNECTOR, clamp cable 1.250 . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 ♦Part of Option 042 983 Ground Current Sensor +When ordering a component originally displaying a precautionary label, the label should also be ordered. *Recommended Spare Parts. To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested Replacement Parts. Model and serial number required when ordering parts from your local distributor. . Hardware is common and 5 not available unless listed. 6 1 8 7 2 9 3 37 9 10 10 4 36 11 12 10 25 35 24 23 25 22 21 26 20 34 33 28 32 13 19 17 30 16 ST-800 706-F Figure 7-2. Panel, Front w/Components OM-277 Page 28 15 27 29 31 14 18 Quantity Item No. Dia. Mkgs. Part No. Model Description 302 452 Figure 7-2. Panel, Front w/Components (Fig 7-1 Item 30) . . . 1 . . . . . . S1 . . . . . . 163 557 . . . SWITCH, mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 1 . . . . . . S1 . . . . . . 163 556 . . . SWITCH, mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 2 . . . . . PC1 . . . . . 187 831 . . . CIRCUIT CARD, control (60Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 2 . . . . . PC1 . . . . . 186 938 . . . CIRCUIT CARD, control (60Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 2 . . . . . PC1 . . . . . 187 832 . . . CIRCUIT CARD, control (50Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 2 . . . . . PC1 . . . . . 187 833 . . . CIRCUIT CARD, control (50Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . . PLG1 . . . . . 158 720 . . . CONNECTOR & SOCKETS, (see Fig 7-3 & 4) . . . . . . . . . . . PLG3 . . . . . 169 240 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . . . . . . . . PLG4 . . . . . 148 439 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . . . . . . . . PLG5 . . . . . 152 249 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 3 . . . . . CR3 . . . . . 006 393 . . . RELAY, encl 24VAC DPDT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 4 . . . . . CR5 . . . . ♦006 393 . . . RELAY, encl 24VAC DPDT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 5 . . . . . CB1,2 . . . . 093 995 . . . CIRCUIT BREAKER, man reset 1P 15A 250VAC . . . . . . . . . . . . . . . . 2 . . . . 2 . . . 6 . . . . . RC9 . . . . . 604 176 . . . RECEPTACLE, str dx grd 2P3W 15A 125V . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 7 . . . . . . . . . . . . . . . . 163 855 . . . CONNECTOR/CAPACITOR, w/leads (consisting of) . . . . . . . . . . . . . 1 . . . . 1 . . . . . . . . . . . RC8 . . . . . 143 976 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . . . . . . . . . C3 . . . . . . 163 863 . . . . LEAD ASSEMBLY, elect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . . . . . . . . . C6 . . . . . . 163 861 . . . . LEAD ASSEMBLY, elect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . . . . . . . . C13 . . . . . 163 858 . . . . LEAD ASSEMBLY, elect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . . . . . . . . C14 . . . . . 163 857 . . . . LEAD ASSEMBLY, elect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 8 . . . . . . . . . . . . . . . . 162 802 . . . PANEL, front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 9 . . POS-CC,CV . . 181 245 . . . TERMINAL, pwr output red . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2 . . . 10 . . . C2,4,5 . . . . 128 750 . . . CAPACITOR, cer disc .1uf 500VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 . . . . 3 . . . 11 . . . . . . . . . . . . . . . 161 303 . . . SPRING, cprsn .600 OD x .072 wire x 1.500 lg . . . . . . . . . . . . . . . . . . 3 . . . . 3 . . . 12 . . . . R4,5 . . . . . 136 076 . . . RESISTOR, WW fxd 30W 200 ohm . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2 . . . 13 . . . . NEG . . . . . 181 246 . . . TERMINAL, pwr output black . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 14 . . . . . . . . . . . . . . . 174 938 . . . PLATE, control lower (60Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 14 . . . . . . . . . . . . . . . 179 388 . . . PLATE, control lower (50Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 15 . . . . . 1T . . . . . . 159 040 . . . BLOCK, term 20A 12P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 16 . . . . . . . . . . . . . . . 162 828 . . . PANEL, mtg rcpt/terminal strip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 17 . . . . . . . . . . . . . . . 070 371 . . . BLANK, snap-in nyl 1.093/1.125mtg hole . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 18 . . . . . . . . . . . . . . . 162 891 . . . LABEL, warning electric shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 19 . . . . . . . . . . . . . . +172 587 . . . COVER, stud output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 20 . . . . . . . . . . . . . . . 160 935 . . . CLIP, spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 . . . . 3 . . . 21 . . . . . . . . . . . . . . . 601 835 . . . NUT, 10-32 brs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2 . . . . . . . . . . . . . . . . . . . . . . 010 913 . . . WASHER, flat .218 ID x .460 OD x .031thk brs . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 22 . . . . . . . . . . . . . . . 159 863 . . . ELECTRONICS BOX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 23 . . . . . . . . . . . . . . . 038 887 . . . STUD, pri bd brs 10-32 x 1.375 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 24 . . . . S3-5 . . . . . 011 609 . . . SWITCH, tgl SPDT 15A 125VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 . . . . 3 . . . 25 . . . . R1,2 . . . . . 035 897 . . . POTENTIOMETER, CP std slot 1/T 2W 1K ohm . . . . . . . . . . . . . . . . . 2 . . . . 2 . . . 26 . . . . PC2 . . . . . 178 130 . . . CIRCUIT CARD, digital meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 26 . . . . PC2 . . . . . 177 909 . . . CIRCUIT CARD, digital meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . PLG10 . . . . 153 501 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . . . . . . . PLG11 . . . . 148 439 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 27 . . . . CR2 . . . . . 000 770 . . . RELAY, encl 24VDC 3PDT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 28 . . . . . . . . . . . . . . . 165 316 . . . STAND-OFF, 6-32 x .875 lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 . . . . 4 . . . 29 . . . . . . . . . . . . . . . . . . . . . . . . . . . NAMEPLATE, (order by model and serial number) . . . . . . . . . . . . . . . 1 . . . . 1 . . . 30 . . . . . S2 . . . . . . 159 039 . . . SWITCH, rocker SPDT 15A 125VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . . . . . . . . PLG2 . . . . . 185 626 . . . CONNECTOR, body 56 series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 31 . . . . . PL2 . . . . . 159 522 . . . LED, yellow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 32 . . . . . . . . . . . . . . . 159 036 . . . LENS, LED clear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 33 . . . . . . . . . . . . . . . 097 924 . . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 34 . . . . . . . . . . . . . . . 097 922 . . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 35 . . . . . . . . . . . . . . . 148 956 . . . HANDLE, switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . 36 . . . . LS1,2 . . . . . 089 645 . . . SWITCH, lim 11A 125V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2 . . . 37 . . . . . . . . . . . . . . . 161 297 . . . CAM, switch selector 2posn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 ♦Part of Option 042 983 Ground Current Sensor +When ordering a component originally displaying a precautionary label, the label should also be ordered. To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested Replacement Parts. Model and serial number required when ordering parts from your local distributor. OM-277 Page 29 Item No. Dia. Mkgs. Part No. Description Quantity Figure 7-3. Rectifier, Si Diode (302 Model) (Fig 7-1 Item 31) . . . 1 . . . . C7-12 . . . . ... 2 ............... ... 3 ............... ... 4 ............... . . . 5 . . . . . TP3 . . . . . . . . 6 . . . . . TP6 . . . . . . . . 7 . . . SCR1-6 . . . . . . . . . . . . . PLG1 . . . . ... 8 ............... 048 420 177 316 177 317 166 667 185 679 185 680 161 668 158 720 188 692 .. .. .. .. .. .. .. .. .. CAPACITOR, cer disc .01uf 1000VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . HEAT SINK, rect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HEAT SINK, rect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CLAMP, thyristor rect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . THERMOSTAT, NC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . THERMOSTAT, NC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . THYRISTOR, SCR 300A 300V hockey puck . . . . . . . . . . . . . . . . . . . . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CLAMP, thyristor rectifier 4.250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hardware is common and 3 not available unless listed. 6 3 2 3 1 1 6 1 3 4 5 2 1 6 7 8 ST-800 697-C Figure 7-3. Rectifier, Si Diode (302 Model) To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested Replacement Parts. Model and serial number required when ordering parts from your local distributor. OM-277 Page 30 Item No. Dia. Mkgs. Part No. Description Quantity Figure 7-4. Rectifier, Si Diode (452 Model) (Fig 7-1 Item 31) . . . 1 . . . . C7-12 . . . . ... 2 ............... ... 3 ............... ... 4 ............... . . . 5 . . . SCR1-6 . . . ... 6 ............... ... 7 ............... . . . . . . . . . . PLG1 . . . . . . . . . . . . . . . TP3 . . . . . . . . . . . . . . . . TP6 . . . . . 048 420 176 168 166 667 160 962 161 668 160 961 188 691 158 720 168 895 168 894 .. .. .. .. .. .. .. .. .. .. . Hardware is common and CAPACITOR, cer disc .01uf 1000VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . BAR, mtg rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CLAMP, spring thyristor rectifier 5.500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . HEAT SINK, rectifier snowflake .800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . THYRISTOR, SCR 300A 300V hockey puck . . . . . . . . . . . . . . . . . . . . . . . HEAT SINK, rectifier snowflake 1.600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CLAMP, thyristor rectifier 5.500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . THERMOSTAT, rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . THERMOSTAT, rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 not available unless listed. 6 2 3 6 6 3 3 1 1 1 3 1 4 5 6 7 ST-800 696-A Figure 7-4. Rectifier, Si Diode (452 Model) To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested Replacement Parts. Model and serial number required when ordering parts from your local distributor. OM-277 Page 31 Item No. Dia. Mkgs. Part No. Description Quantity Figure 7-5. Panel, Rear w/Components (Fig 7-1 Item 18) . . . 1 . . . . . . . . . . . . . . . 173 283 . . . 2 . . . . . . . . . . . . . . . 180 165 . . . 3 . . . . . . . . . . . . . . . 162 807 . . . 4 . . . . . . . . . . . . . . . 168 343 . . . 5 . . . . . . . . . . . . . . +162 818 . . . 6 . . . . . . . . . . . . . . . 168 384 . . . 7 . . . . . . . . . . . . . . . 602 177 . . . 8 . . . . . . . . . . . . . . . 124 274 . . . 9 . . . . . R3 . . . . . . 097 459 . . . 10 . . . . . FM . . . . . 116 190 . . . . . . . . . . . . . . . . . . . . . 010 467 .. .. .. .. .. .. .. .. .. .. .. CHAMBER, plenum 14 in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BLADE, fan 14 in 3wg 28deg .375 bore CCW . . . . . . . . . . . . . . . . . . . . . . PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HINGE, door primary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DOOR, access primary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LABEL, warning electric shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SCREW, set .250-20 x .250knrlpt sch stl . . . . . . . . . . . . . . . . . . . . . . . . . . BRACKET, mtg fan motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RESISTOR, WW fxd 375W 20 ohm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MOTOR, 1/12HP 230V 1550RPM 50/60Hz 1.5A . . . . . . . . . . . . . . . . . . . CONNECTOR, clamp cable 1.250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hardware is common and 3 not available unless listed. 1 1 1 2 1 1 2 1 1 1 1 4 5 6 2 1 7 8 10 9 ST-800 707-A Figure 7-5. Panel, Rear w/Components +When ordering a component originally displaying a precautionary label, the label should also be ordered. To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested Replacement Parts. Model and serial number required when ordering parts from your local distributor. OM-277 Page 32 Effective January 1, 1998 (Equipment with a serial number preface of “KJ” or newer) This limited warranty supersedes all previous Miller warranties and is exclusive with no other guarantees or warranties expressed or implied. LIMITED WARRANTY − Subject to the terms and conditions below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants to its original retail purchaser that new Miller equipment sold after the effective date of this limited warranty is free of defects in material and workmanship at the time it is shipped by Miller. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS. Within the warranty periods listed below, Miller will repair or replace any warranted parts or components that fail due to such defects in material or workmanship. Miller must be notified in writing within thirty (30) days of such defect or failure, at which time Miller will provide instructions on the warranty claim procedures to be followed. Miller shall honor warranty claims on warranted equipment listed below in the event of such a failure within the warranty time periods. All warranty time periods start on the date that the equipment was delivered to the original retail purchaser, or one year after the equipment is sent to a North American distributor or eighteen months after the equipment is sent to an International distributor. 1. 2. 3. 5 Years Parts − 3 Years Labor * Original main power rectifiers * Inverters (input and output rectifiers only) 3 Years — Parts and Labor * Transformer/Rectifier Power Sources * Plasma Arc Cutting Power Sources * Semi-Automatic and Automatic Wire Feeders * Inverter Power Supplies * Intellitig * Engine Driven Welding Generators (NOTE: Engines are warranted separately by the engine manufacturer.) 1 Year — Parts and Labor * Motor Driven Guns (w/exception of Spoolmate 185) * Process Controllers * Positioners and Controllers * Automatic Motion Devices * Robots * IHPS Power Sources * Water Coolant Systems * HF Units * Grids * Spot Welders * Load Banks * SDX Transformers * Miller Cyclomatic Equipment * Running Gear/Trailers * Plasma Cutting Torches (except APT, ZIPCUT & PLAZCUT Models) * Deutz Engines (outside North America) * Field Options (NOTE: Field options are covered under True Blue® for the remaining warranty period of the product they are installed in, or for a minimum of one year — whichever is greater.) 4. 6 Months — Batteries 5. 90 Days — Parts and Labor * MIG Guns/TIG Torches * APT, ZIPCUT & PLAZCUT Model Plasma Cutting Torches * Remote Controls * Accessory Kits * Replacement Parts (No labor) * Spoolmate 185 Miller’s True Blue® Limited Warranty shall not apply to: 1. Items furnished by Miller, but manufactured by others, such as engines or trade accessories. These items are covered by the manufacturer’s warranty, if any. 2. Consumable components; such as contact tips, cutting nozzles, contactors, brushes, slip rings, relays or parts that fail due to normal wear. 3. Equipment that has been modified by any party other than Miller, or equipment that has been improperly installed, improperly operated or misused based upon industry standards, or equipment which has not had reasonable and necessary maintenance, or equipment which has been used for operation outside of the specifications for the equipment. MILLER PRODUCTS ARE INTENDED FOR PURCHASE AND USE BY COMMERCIAL/INDUSTRIAL USERS AND PERSONS TRAINED AND EXPERIENCED IN THE USE AND MAINTENANCE OF WELDING EQUIPMENT. In the event of a warranty claim covered by this warranty, the exclusive remedies shall be, at Miller’s option: (1) repair; or (2) replacement; or, where authorized in writing by Miller in appropriate cases, (3) the reasonable cost of repair or replacement at an authorized Miller service station; or (4) payment of or credit for the purchase price (less reasonable depreciation based upon actual use) upon return of the goods at customer’s risk and expense. Miller’s option of repair or replacement will be F.O.B., Factory at Appleton, Wisconsin, or F.O.B. at a Miller authorized service facility as determined by Miller. Therefore no compensation or reimbursement for transportation costs of any kind will be allowed. TO THE EXTENT PERMITTED BY LAW, THE REMEDIES PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF PROFIT), WHETHER BASED ON CONTRACT, TORT OR ANY OTHER LEGAL THEORY. Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND ANY IMPLIED WARRANTY, GUARANTY OR REPRESENTATION AS TO PERFORMANCE, AND ANY REMEDY FOR BREACH OF CONTRACT TORT OR ANY OTHER LEGAL THEORY WHICH, BUT FOR THIS PROVISION, MIGHT ARISE BY IMPLICATION, OPERATION OF LAW, CUSTOM OF TRADE OR COURSE OF DEALING, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE, WITH RESPECT TO ANY AND ALL EQUIPMENT FURNISHED BY MILLER IS EXCLUDED AND DISCLAIMED BY MILLER. Some states in the U.S.A. do not allow limitations of how long an implied warranty lasts, or the exclusion of incidental, indirect, special or consequential damages, so the above limitation or exclusion may not apply to you. This warranty provides specific legal rights, and other rights may be available, but may vary from state to state. In Canada, legislation in some provinces provides for certain additional warranties or remedies other than as stated herein, and to the extent that they may not be waived, the limitations and exclusions set out above may not apply. This Limited Warranty provides specific legal rights, and other rights may be available, but may vary from province to province. miller_warr 1/98 Owner’s Record Please complete and retain with your personal records. Model Name Serial/Style Number Purchase Date (Date which equipment was delivered to original customer.) Distributor Address City State Zip Resources Available Always provide Model Name and Serial/Style Number. Contact your Distributor for: To locate distributor nearest you call 1-800-4-A-Miller. Welding Supplies and Consumables Options and Accessories Personal Safety Equipment Service and Repair Miller Electric Mfg. Co. An Illinois Tool Works Company 1635 West Spencer Street Appleton, WI 54914 USA Replacement Parts Training (Schools, Videos, Books) International Headquarters−USA USA Phone: 920-735-4505 Auto-Attended USA & Canada FAX: 920-735-4134 International FAX: 920-735-4125 Technical Manuals (Servicing Information and Parts) Circuit Diagrams European Headquarters − United Kingdom Phone: 44 (0) 1204-593493 FAX: 44 (0) 1204-598066 Welding Process Handbooks www.MillerWelds.com Contact the Delivering Carrier for: For assistance in filing or settling claims, contact your distributor and/or equipment manufacturer’s Transportation Department. PRINTED IN USA File a claim for loss or damage during shipment. © 1998 Miller Electric Mfg. Co. 9/98
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project