Miller | KH513600 | Owner Manual | Miller DYNASTY DX User manual

Miller DYNASTY DX User manual
OM-357A
185796
October 1997
Processes
TIG (GTAW) Welding
Stick (SMAW) Welding
Description
Arc Welding Power Source
Dynasty DX

With Auto-Link
Visit our website at
www.millerwelds.com
From Miller to You
Thank you and congratulations on choosing Miller. Now
you can get the job done and get it done right. We know
you don’t have time to do it any other way.
That’s why when Niels Miller first started building arc
welders in 1929, he made sure his products offered
long-lasting value and superior quality. Like you, his
customers couldn’t afford anything less. Miller products
had to be more than the best they could be. They had to
be the best you could buy.
Today, the people that build and sell Miller products continue the
tradition. They’re just as committed to providing equipment and service
that meets the high standards of quality and value established in 1929.
This Owner’s Manual is designed to help you get the most out of your
Miller products. Please take time to read the Safety precautions. They will
help you protect yourself against potential hazards on the worksite. We’ve
made installation and operation quick and easy.
With Miller you can count on years of reliable
service with proper maintenance. And if for
some reason the unit needs repair, there’s a
Troubleshooting section that will help you
Miller is the first weld- figure out what the problem is. The parts list
ing
equipment will then help you to decide which exact part
manufacturer in the
you may need to fix the problem. Warranty and
U.S.A. to be registered
to the ISO 9001 Quality service information for your particular model
System Standard.
are also provided.
Working as hard as you
do − every power source
from Miller is backed by
the most hassle-free warranty in the business.
Miller Electric manufactures a full line
of welders and welding related equipment.
For information on other quality Miller
products, contact your local Miller distributor
to receive the latest full line catalog or
individual catalog sheets. To locate your nearest
distributor call 1-800-4-A-Miller.
Call
1-800-4-A-MILLER
for your local
Miller distributor.
Your distributor gives
you ...
Service
You always get the fast,
reliable response you
need. Most replacement
parts can be in your
hands in 24 hours.
Support
Need fast answers to the
tough welding questions?
Contact your distributor.
The expertise of the
distributor and Miller is
there to help you, every
step of the way.
Miller offers a Technical
Manual which provides
more detailed service and
parts information for your
unit. To obtain a Technical
Manual, contact your local
distributor. Your distributor
can also supply you with
Welding Process Manuals
such as SMAW, GTAW,
GMAW, and GMAW-P.
For practical information on
welding, process applications, and Miller products,
visit our website at
www.millerwelds.com
The following terms are
used interchangeably
throughout this manual:
TIG = GTAW
Stick = SMAW
TABLE OF CONTENTS
SECTION 1 − SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Additional Symbols for Installation, Operation, and Maintenance . . . . . . . . . . . . . . . . . . . . . . .
1-4. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 1 − CONSIGNES DE SECURITE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1. Signification des symboles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Dangers relatifs au soudage à l’arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement
et la maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. Information sur les champs électromagnétiques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 − INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2. Duty Cycle and Overheating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3. Volt-Ampere Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-4. Selecting a Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-5. Weld Output Terminals and Selecting Cable Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-6. Remote 14 Receptacle Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-7. 115 Volts AC Duplex Receptacle (Optional) and Power Switch Location . . . . . . . . . . . . . . . . .
2-8. Electrical Service Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-9. Connecting Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 − OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1. Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2. AC/Balance Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-3. Meter Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-4. Output Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-5. Sequence Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-6. Lift-Arc and HF TIG Start Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 4 − MAINTENANCE AND TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. Overload Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3. Blowing Out Inside of Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-4. Voltmeter/Ammeter Help Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-5. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 5 − ELECTRICAL DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-1. Circuit Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 − HIGH FREQUENCY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-1. Welding Processes Requiring High Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-2. Incorrect Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-3. Correct Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 − Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
3
3
4
5
5
5
7
8
8
9
9
9
10
11
12
12
13
13
14
15
15
16
16
16
17
17
18
18
18
19
20
22
22
24
24
24
25
26
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING
som _nd_5/97
1-1. Symbol Usage
Means Warning! Watch Out! There are possible hazards
with this procedure! The possible hazards are shown in
the adjoining symbols.
Y Marks a special safety message.
. Means “Note”; not safety related.
This group of symbols means Warning! Watch Out! possible
ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.
Consult symbols and related instructions below for necessary actions
to avoid the hazards.
1-2. Arc Welding Hazards
Y The symbols shown below are used throughout this manual to
call attention to and identify possible hazards. When you see
the symbol, watch out, and follow the related instructions to
avoid the hazard. The safety information given below is only
a summary of the more complete safety information found in
the Safety Standards listed in Section 1-5. Read and follow all
Safety Standards.
D If earth grounding of the workpiece is required, ground it directly
with a separate cable − do not use work clamp or work cable.
Y Only qualified persons should install, operate, maintain, and
repair this unit.
D Wear a safety harness if working above floor level.
D Keep all panels and covers securely in place.
Y During operation, keep everybody, especially children, away.
D Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shocks
or severe burns. The electrode and work circuit is
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also
live when power is on. In semiautomatic or automatic wire welding, the
wire, wire reel, drive roll housing, and all metal parts touching the
welding wire are electrically live. Incorrectly installed or improperly
grounded equipment is a hazard.
D Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
D Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
D Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
D Do not connect more than one electrode or work cable to any
single weld output terminal.
SIGNIFICANT DC VOLTAGE exists after removal of
input power on inverters.
D Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section
before touching any parts.
D Do not touch live electrical parts.
D Wear dry, hole-free insulating gloves and body protection.
D Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.
D Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
D Use AC output ONLY if required for the welding process.
D If AC output is required, use remote output control if present on
unit.
D Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
D Properly install and ground this equipment according to its
Owner’s Manual and national, state, and local codes.
D Keep your head out of the fumes. Do not breathe the fumes.
D Always verify the supply ground − check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
grounded receptacle outlet.
D When making input connections, attach proper grounding conductor first − double-check connections.
D Frequently inspect input power cord for damage or bare wiring −
replace cord immediately if damaged − bare wiring can kill.
D Turn off all equipment when not in use.
D Do not use worn, damaged, undersized, or poorly spliced cables.
D Do not weld in locations near degreasing, cleaning, or spraying operations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.
D Do not drape cables over your body.
FUMES AND GASES can be hazardous.
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health.
D If inside, ventilate the area and/or use exhaust at the arc to remove
welding fumes and gases.
D If ventilation is poor, use an approved air-supplied respirator.
D Read the Material Safety Data Sheets (MSDSs) and the
manufacturer’s instructions for metals, consumables, coatings,
cleaners, and degreasers.
D Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watchperson nearby. Welding fumes and gases can displace air and
lower the oxygen level causing injury or death. Be sure the breathing air is safe.
D Do not weld on coated metals, such as galvanized, lead, or
cadmium plated steel, unless the coating is removed from the weld
area, the area is well ventilated, and if necessary, while wearing an
air-supplied respirator. The coatings and any metals containing
these elements can give off toxic fumes if welded.
OM-357 Page 1
ARC RAYS can burn eyes and skin.
Arc rays from the welding process produce intense
visible and invisible (ultraviolet and infrared) rays
that can burn eyes and skin. Sparks fly off from the
weld.
D Wear a welding helmet fitted with a proper shade of filter to protect
your face and eyes when welding or watching (see ANSI Z49.1
and Z87.1 listed in Safety Standards).
D Wear approved safety glasses with side shields under your
helmet.
D Use protective screens or barriers to protect others from flash and
glare; warn others not to watch the arc.
D Wear protective clothing made from durable, flame-resistant material (leather and wool) and foot protection.
BUILDUP OF GAS can injure or kill.
D Shut off shielding gas supply when not in use.
D Always ventilate confined spaces or use
approved air-supplied respirator.
HOT PARTS can cause severe burns.
D Do not touch hot parts bare handed.
D Allow cooling period before working on gun or
torch.
MAGNETIC FIELDS can affect pacemakers.
WELDING can cause fire or explosion.
Welding on closed containers, such as tanks,
drums, or pipes, can cause them to blow up. Sparks
can fly off from the welding arc. The flying sparks, hot
workpiece, and hot equipment can cause fires and
burns. Accidental contact of electrode to metal objects can cause
sparks, explosion, overheating, or fire. Check and be sure the area is
safe before doing any welding.
D Protect yourself and others from flying sparks and hot metal.
D Do not weld where flying sparks can strike flammable material.
D Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
D Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
D Watch for fire, and keep a fire extinguisher nearby.
D Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
D Do not weld on closed containers such as tanks, drums, or pipes,
unless they are properly prepared according to AWS F4.1 (see
Safety Standards).
D Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly
unknown paths and causing electric shock and fire hazards.
D Do not use welder to thaw frozen pipes.
D Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
D Wear oil-free protective garments such as leather gloves, heavy
shirt, cuffless trousers, high shoes, and a cap.
D Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.
FLYING METAL can injure eyes.
D Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool,
they can throw off slag.
D Wear approved safety glasses with side
shields even under your welding helmet.
OM-357 Page 2
D Pacemaker wearers keep away.
D Wearers should consult their doctor before
going near arc welding, gouging, or spot
welding operations.
NOISE can damage hearing.
Noise from some processes or equipment can
damage hearing.
D Wear approved ear protection if noise level is
high.
CYLINDERS can explode if damaged.
Shielding gas cylinders contain gas under high
pressure. If damaged, a cylinder can explode. Since
gas cylinders are normally part of the welding
process, be sure to treat them carefully.
D Protect compressed gas cylinders from excessive heat, mechanical shocks, slag, open flames, sparks, and arcs.
D Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
D Keep cylinders away from any welding or other electrical circuits.
D Never drape a welding torch over a gas cylinder.
D Never allow a welding electrode to touch any cylinder.
D Never weld on a pressurized cylinder − explosion will result.
D Use only correct shielding gas cylinders, regulators, hoses, and fittings designed for the specific application; maintain them and
associated parts in good condition.
D Turn face away from valve outlet when opening cylinder valve.
D Keep protective cap in place over valve except when cylinder is in
use or connected for use.
D Read and follow instructions on compressed gas cylinders,
associated equipment, and CGA publication P-1 listed in Safety
Standards.
1-3. Additional Symbols for Installation, Operation, and Maintenance
FIRE OR EXPLOSION hazard.
MOVING PARTS can cause injury.
D Do not install or place unit on, over, or near
combustible surfaces.
D Do not install unit near flammables.
D Do not overload building wiring − be sure power supply system is
properly sized, rated, and protected to handle this unit.
D Keep away from moving parts such as fans.
D Keep all doors, panels, covers, and guards
closed and securely in place.
FALLING UNIT can cause injury.
H.F. RADIATION can cause interference.
D Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
D Use equipment of adequate capacity to lift and
support unit.
D If using lift forks to move unit, be sure forks are
long enough to extend beyond opposite side of
unit.
D
OVERUSE can cause OVERHEATING
D
D Allow cooling period; follow rated duty cycle.
D Reduce current or reduce duty cycle before
starting to weld again.
D Do not block or filter airflow to unit.
D
D
D High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communications equipment.
D Have only qualified persons familiar with
electronic equipment perform this installation.
The user is responsible for having a qualified electrician promptly correct any interference problem resulting from the installation.
If notified by the FCC about interference, stop using the
equipment at once.
Have the installation regularly checked and maintained.
Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.
STATIC (ESD) can damage PC boards.
D Put on grounded wrist strap BEFORE handling
boards or parts.
D Use proper static-proof bags and boxes to
store, move, or ship PC boards.
ARC WELDING can cause interference.
MOVING PARTS can cause injury.
D Keep away from moving parts.
D Keep away from pinch points such as drive
rolls.
D
D
WELDING WIRE can cause injury.
D Do not press gun trigger until instructed to do
so.
D Do not point gun toward any part of the body,
other people, or any metal when threading
welding wire.
D
D
D Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.
D Be sure all equipment in the welding area is
electromagnetically compatible.
To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
Locate welding operation 100 meters from any sensitive electronic equipment.
Be sure this welding machine is installed and grounded
according to this manual.
If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables,
using line filters, or shielding the work area.
1-4. Principal Safety Standards
Safety in Welding and Cutting, ANSI Standard Z49.1, from American
Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126
Safety and Health Standards, OSHA 29 CFR 1910, from Superintendent of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Recommended Safe Practices for the Preparation for Welding and Cutting of Containers That Have Held Hazardous Substances, American
Welding Society Standard AWS F4.1, from American Welding Society,
550 N.W. LeJeune Rd, Miami, FL 33126
National Electrical Code, NFPA Standard 70, from National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
Code for Safety in Welding and Cutting, CSA Standard W117.2, from
Canadian Standards Association, Standards Sales, 178 Rexdale
Boulevard, Rexdale, Ontario, Canada M9W 1R3.
Safe Practices For Occupation And Educational Eye And Face
Protection, ANSI Standard Z87.1, from American National Standards
Institute, 1430 Broadway, New York, NY 10018.
Cutting And Welding Processes, NFPA Standard 51B, from National
Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
OM-357 Page 3
1-5. EMF Information
Considerations About Welding And The Effects Of Low Frequency
Electric And Magnetic Fields
1. Keep cables close together by twisting or taping them.
Welding current, as it flows through welding cables, will cause electromagnetic fields. There has been and still is some concern about such
fields. However, after examining more than 500 studies spanning 17
years of research, a special blue ribbon committee of the National
Research Council concluded that: “The body of evidence, in the
committee’s judgment, has not demonstrated that exposure to powerfrequency electric and magnetic fields is a human-health hazard.”
However, studies are still going forth and evidence continues to be
examined. Until the final conclusions of the research are reached, you
may wish to minimize your exposure to electromagnetic fields when
welding or cutting.
2. Arrange cables to one side and away from the operator.
To reduce magnetic fields in the workplace, use the following
procedures:
Pacemaker wearers consult your doctor first. If cleared by your doctor,
then following the above procedures is recommended.
OM-357 Page 4
3. Do not coil or drape cables around your body.
4. Keep welding power source and cables as far away from operator as practical.
5. Connect work clamp to workpiece as close to the weld as possible.
About Pacemakers:
SECTION 1 − CONSIGNES DE SECURITE
− LIRE AVANT UTILISATION
som _nd_Fre 4/97
1-1. Signification des symboles
Signifie Mise en garde ! Soyez vigilant ! Cette procédure
présente des risques de danger ! Ceux-ci sont identifiés
par des symboles adjacents aux directives.
Y Identifie un message de sécurité particulier.
. Signifie NOTA ; n’est pas relatif à la sécurité.
Ce groupe de symboles signifie Mise en garde ! Soyez vigilant ! Il y a des
risques de danger reliés aux CHOCS ÉLECTRIQUES, aux PIÈCES EN
MOUVEMENT et aux PIÈCES CHAUDES. Reportez-vous aux symboles
et aux directives ci-dessous afin de connaître les mesures à prendre pour
éviter tout danger.
1-2. Dangers relatifs au soudage à l’arc
Y Les symboles présentés ci-après sont utilisés tout au long du
présent manuel pour attirer votre attention et identifier les risques
de danger. Lorsque vous voyez un symbole, soyez vigilant et
suivez les directives mentionnées afin d’éviter tout danger. Les
consignes de sécurité présentées ci-après ne font que résumer
l’information contenue dans les normes de sécurité énumérées
à la section 1-5. Veuillez lire et respecter toutes ces normes de
sécurité.
D N’utiliser qu’un matériel en bon état. Réparer ou remplacer sur-lechamp les pièces endommagées. Entretenir l’appareil conformément
à ce manuel.
D Porter un harnais de sécurité quand on travaille en hauteur.
D Maintenir solidement en place tous les panneaux et capots.
Y L’installation, l’utilisation, l’entretien et les réparations ne doivent être confiés qu’à des personnes qualifiées.
D Fixer le câble de retour de façon à obtenir un bon contact métal-métal
avec la pièce à souder ou la table de travail, le plus près possible de la
soudure.
Y Au cours de l’utilisation, tenir toute personne à l’écart et plus particulièrement les enfants.
D
Isoler la pince de masse quand pas mis à la pièce pour éviter le contact
avec tout objet métallique.
UN CHOC ÉLECTRIQUE peut tuer.
Un simple contact avec des pièces électriques peut
provoquer une électrocution ou des blessures graves.
L’électrode et le circuit de soudage sont sous tension
dès que l’appareil est sur ON. Le circuit d’entrée et les
circuits internes de l’appareil sont également sous
tension à ce moment-là. En soudage semi-automatique ou automatique,
le fil, le dévidoir, le logement des galets d’entraînement et les pièces
métalliques en contact avec le fil de soudage sont sous tension. Des
matériels mal installés ou mal mis à la terre présentent un danger.
Il y a DU COURANT CONTINU IMPORTANT dans les
convertisseurs après la suppression de l’alimentation électrique.
D Arrêter les convertisseurs, débrancher le courant électrique, et décharger les condensateurs d’alimentation selon les instructions
indiquées dans la partie entretien avant de toucher les pièces.
D Ne jamais toucher les pièces électriques sous tension.
D Porter des gants et des vêtements de protection secs ne comportant
pas de trous.
D S’isoler de la pièce et de la terre au moyen de tapis ou d’autres
moyens isolants suffisamment grands pour empêcher le contact physique éventuel avec la pièce ou la terre.
D
D
D
Ne pas se servir de source électrique àcourant électrique dans les zones
humides, dans les endroits confinés ou là où on risque de tomber.
Se servir d’une source électrique àcourant électrique UNIQUEMENT si le
procédé de soudage le demande.
Si l’utilisation d’une source électrique àcourant électrique s’avère nécessaire, se servir de la fonction de télécommande si l’appareil en est équipé.
D Couper l’alimentation ou arrêter le moteur avant de procéder à l’installation, à la réparation ou à l’entretien de l’appareil. Déverrouiller
l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de
sécurité).
D Installer et mettre à la terre correctement cet appareil conformément à
son manuel d’utilisation et aux codes nationaux, provinciaux et
municipaux.
D Toujours vérifier la terre du cordon d’alimentation − Vérifier et s’assurer que le fil de terre du cordon d’alimentation est bien raccordé à la
borne de terre du sectionneur ou que la fiche du cordon est raccordée
à une prise correctement mise à la terre.
D En effectuant les raccordements d’entrée fixer d’abord le conducteur
de mise à la terre approprié et contre-vérifier les connexions.
D Vérifier fréquemment le cordon d’alimentation pour voir s’il n’est pas
endommagé ou dénudé − remplacer le cordon immédiatement s’il est
endommagé − un câble dénudé peut provoquer une électrocution.
D Mettre l’appareil hors tension quand on ne l’utilise pas.
D Ne pas utiliser des câbles usés, endommagés, de grosseur insuffisante ou mal épissés.
D Ne pas enrouler les câbles autour du corps.
D Si la pièce soudée doit être mise à la terre, le faire directement avec un
câble distinct − ne pas utiliser le connecteur de pièce ou le câble de
retour.
D Ne pas toucher l’électrode quand on est en contact avec la pièce, la
terre ou une électrode provenant d’une autre machine.
LES FUMÉES ET LES GAZ peuvent
être dangereux.
Le soudage génère des fumées et des gaz. Leur
inhalation peut être dangereux pour votre santé.
D
D
D
D
D
D
D Eloigner votre tête des fumées. Ne pas respirer
les fumées.
A l’intérieur, ventiler la zone et/ou utiliser un échappement au niveau
de l’arc pour l’évacuation des fumées et des gaz de soudage.
Si la ventilation est insuffisante, utiliser un respirateur à alimentation d’air homologué.
Lire les spécifications de sécurité des matériaux (MSDSs) et les
instructions du fabricant concernant les métaux, les consommables, les revêtements, les nettoyants et les dégraisseurs.
Travailler dans un espace fermé seulement s’il est bien ventilé ou en
portant un respirateur à alimentation d’air. Demander toujours à un
surveillant dûment formé de se tenir à proximité. Des fumées et des
gaz de soudage peuvent déplacer l’air et abaisser le niveau d’oxygène provoquant des blessures ou des accidents mortels. S’assurer que l’air de respiration ne présente aucun danger.
Ne pas souder dans des endroits situés à proximité d’opérations de
dégraissage, de nettoyage ou de pulvérisation. La chaleur et les
rayons de l’arc peuvent réagir en présence de vapeurs et former des
gaz hautement toxiques et irritants.
Ne pas souder des métaux munis d’un revêtement, tels que l’acier
galvanisé, plaqué en plomb ou au cadmium à moins que le revêtement n’ait été enlevé dans la zone de soudure, que l’endroit soit bien
ventilé, et si nécessaire, en portant un respirateur à alimentation
d’air. Les revêtements et tous les métaux renfermant ces éléments
peuvent dégager des fumées toxiques en cas de soudage.
OM-357 Page 5
LES RAYONS DE L’ARC peuvent provoquer des brûlures dans les yeux et
sur la peau.
Le rayonnement de l’arc du procédé de soudage
génère des rayons visibles et invisibles intenses
(ultraviolets et infrarouges) susceptibles de provoquer
des brûlures dans les yeux et sur la peau. Des étincelles sont projetées
pendant le soudage.
D Porter un casque de soudage muni d’un écran de filtre approprié pour
protéger votre visage et vos yeux pendant le soudage ou pour regarder (voir ANSI Z49.1 et Z87.1 énuméré dans les normes de sécurité).
D Porter des protections approuvés pour les oreilles si le niveau sondre est
trop élevé.
D Utiliser des écrans ou des barrières pour protéger des tiers de l’éclair
et de l’éblouissement; demander aux autres personnes de ne pas regarder l’arc.
D Porter des vêtements de protection constitué dans une matière durable, résistant au feu (cuir ou laine) et une protection des pieds.
LE SOUDAGE peut provoquer un
incendie ou une explosion.
Le soudage effectué sur des conteneurs fermés tels
que des réservoirs, tambours ou des conduites peut
provoquer leur éclatement. Des étincelles peuvent être
projetées de l’arc de soudure. La projection d’étincelles, des pièces chaudes et des équipements chauds peut provoquer des
incendies et des brûlures. Le contact accidentel de l’électrode avec des
objets métalliques peut provoquer des étincelles, une explosion, un
surchauffement ou un incendie. Avant de commencer le soudage, vérifier
et s’assurer que l’endroit ne présente pas de danger.
D Se protéger et d’autres personnes de la projection d’étincelles et de
métal chaud.
D Ne pas souder dans un endroit là où des étincelles peuvent tomber sur
des substances inflammables.
D Déplacer toutes les substances inflammables à une distance de 10,7
m de l’arc de soudage. En cas d’impossibilité les recouvrir soigneusement avec des protections homologués.
D Des étincelles et des matériaux chauds du soudage peuvent facilement passer dans d’autres zones en traversant de petites fissures et
des ouvertures.
D Surveiller tout déclenchement d’incendie et tenir un extincteur à proximité.
D Le soudage effectué sur un plafond, plancher, paroi ou séparation
peut déclencher un incendie de l’autre côté.
D Ne pas effectuer le soudage sur des conteneurs fermés tels que des
réservoirs, tambours, ou conduites, à moins qu’ils n’aient été préparés correctement conformément à AWS F4.1 (voir les normes de
sécurité).
D Brancher le câble sur la pièce le plus près possible de la zone de soudage pour éviter le transport du courant sur une longue distance par
des chemins inconnus éventuels en provoquant des risques d’électrocution et d’incendie.
D Ne pas utiliser le poste de soudage pour dégeler des conduites gelées.
D En cas de non utilisation, enlever la baguette d’électrode du porteélectrode ou couper le fil à la pointe de contact.
D Porter des vêtements de protection dépourvus d’huile tels que des
gants en cuir, une chemise en matériau lourd, des pantalons sans revers, des chaussures hautes et un couvre chef.
D Avant de souder, retirer toute substance combustible de vos poches
telles qu’un allumeur au butane ou des allumettes.
DES PARTICULES VOLANTES
peuvent blesser les yeux.
D Le soudage, l’écaillement, le passage de la pièce
à la brosse en fil de fer, et le meulage génèrent
des étincelles et des particules métalliques volantes. Pendant la période de refroidissement des soudures, elles risquent de projeter du laitier.
D
Porter des lunettes de sécurité avec écrans latéraux ou un écran facial.
OM-357 Page 6
LES ACCUMULATIONS DE GAZ risquent de provoquer des blessures ou
même la mort.
Fermer l’alimentation du gaz protecteur en cas de
non utilisation.
Veiller toujours à bien aérer les espaces confinés ou se servir d’un respirateur d’adduction d’air homologué.
D
D
DES PIÈCES CHAUDES peuvent provoquer des brûlures graves.
D Ne pas toucher des parties chaudes à mains nues
D Prévoir une période de refroidissement avant
d’utiliser le pistolet ou la torche.
LES CHAMPS MAGNÉTIQUES peuvent
affecter les stimulateurs cardiaques.
D
D
Porteurs de stimulateur cardiaque, restez à distance.
Les porteurs d’un stimulateur cardiaque doivent
d’abord consulter leur médecin avant de s’approcher
des opérations de soudage à l’arc, de gougeage ou
de soudage par points.
LE BRUIT peut affecter l’ouïe.
Le bruit des processus et des équipements peut affecter
l’ouïe.
D
Porter des protections approuvés pour les oreilles si
le niveau sondre est trop élevé.
Si des BOUTEILLES sont endommagées, elles pourront exploser.
Des bouteilles de gaz protecteur contiennent du gaz
sous haute pression. Si une bouteille est endommagée, elle peut exploser. Du fait que les bouteilles de gaz
font normalement partie du procédé de soudage, les
manipuler avec précaution.
D Protéger les bouteilles de gaz comprimé d’une chaleur excessive,
des chocs mécaniques, du laitier, des flammes ouvertes, des étincelles et des arcs.
D Placer les bouteilles debout en les fixant dans un support stationnaire ou dans un porte-bouteilles pour les empêcher de tomber ou de
se renverser.
D Tenir les bouteilles éloignées des circuits de soudage ou autres circuits électriques.
D Ne jamais placer une torche de soudage sur une bouteille à gaz.
D Une électrode de soudage ne doit jamais entrer en contact avec une
bouteille.
D Ne jamais souder une bouteille pressurisée − risque d’explosion.
D Utiliser seulement des bouteilles de gaz protecteur, régulateurs,
tuyaux et raccords convenables pour cette application spécifique;
les maintenir ainsi que les éléments associés en bon état.
D Ne pas tenir la tête en face de la sortie en ouvrant la soupape de la
bouteille.
D Maintenir le chapeau de protection sur la soupape, sauf en cas d’utilisation ou de branchement de la bouteille.
D Lire et suivre les instructions concernant les bouteilles de gaz comprimé, les équipements associés et les publications P-1 CGA énumérées dans les normes de sécurité.
1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement
et la maintenance
Risque D’INCENDIE OU
D’EXPLOSION.
DES ORGANES MOBILES peuvent
provoquer des blessures.
D Ne pas placer l’appareil sur, au-dessus ou à proximité de surfaces infllammables.
D Rester à l’écart des organes mobiles comme le
ventilateur.
D Maintenir fermés et fixement en place les portes,
panneaux, recouvrements et dispositifs de
protection.
D Ne pas installer l’appareil à proximité de produits inflammables
D Ne pas surcharger l’installation électrique − s”assurer que l’alimentation est correctement dimensionné et protégé avant de mettre
l’appareil en service.
LE RAYONNEMENT HAUTE FRÉQUENCE (H.F.) risque de provoquer
des interférences.
LA CHUTE DE L’APPAREIL peut
blesser.
D Utiliser l’anneau de levage uniquement pour soulever l’appareil, NON PAS les chariot, les bouteilles de gaz ou tout autre accessoire.
D Utiliser un engin d’une capacité appropriée pour
soulever l’appareil.
D En utilisant des fourches de levage pour déplacer l’unité, s’assurer
que les fourches sont suffisamment longues pour dépasser du côté
opposé de l’appareil.
L’EMPLOI EXCESSIF peut
SURCHAUFFER L’ÉQUIPEMENT.
D
D
D
D
D
D Prévoir une période de refroidissement, respecter le cycle opératoire nominal.
D Réduire le courant ou le cycle opératoire avant de
recommancer le soudage.
LE SOUDAGE À L’ARC risque de
provoquer des interférences.
D Ne pas obstruer les passages d’air du poste.
LES CHARGES ÉLECTROSTATIQUES peuvent endommager les circuits imprimés.
D Établir la connexion avec la barrette de terre
avant de manipuler des cartes ou des pièces.
D Utiliser des pochettes et des boîtes antistatiques
pour stocker, déplacer ou expédier des cartes de
circuits imprimes.
DES ORGANES MOBILES peuvent
provoquer des blessures.
D Ne pas s’approcher des organes mobiles.
D Ne pas s’approcher des points de coincement
tels que des rouleaux de commande.
LES FILS DE SOUDAGE peuvent provoquer des blessures.
D Ne pas appuyer sur la gachette avant d’en avoir
reçu l’instruction.
D Ne pas diriger le pistolet vers soi, d’autres personnes ou toute pièce mécanique en engageant le fil
de soudage.
D Le rayonnement haute frequence peut provoquer
des interférences avec les équipements de radio−navigation et de communication, les services
de sécurité et les ordinateurs.
Demander seulement à des personnes qualifiées familiarisées
avec des équipements électroniques de faire fonctionner l’installation.
L’utilisateur est tenu de faire corriger rapidement par un électricien
qualifié les interférences résultant de l’installation.
Si le FCC signale des interférences, arrêter immédiatement l’appareil.
Effectuer régulièrement le contrôle et l’entretien de l’installation.
Maintenir soigneusement fermés les portes et les panneaux des
sources de haute fréquence, maintenir les éclateurs à une distance
correcte et utiliser une terre et et un blindage pour réduire les interférences éventuelles.
D
D
D
D
D
D L’énergie électromagnétique risque de provoquer
des interférences pour l’équipement électronique
sensible tel que les ordinateurs et l’équipement
commandé par ordinateur tel que les robots.
Veiller à ce que tout l’équipement de la zone de soudage soit compatible électromagnétiquement.
Pour réduire la possibilité d’interférence, maintenir les câbles de
soudage aussi courts que possible, les grouper, et les poser aussi
bas que possible (ex. par terre).
Veiller à souder à une distance de 100 mètres de tout équipement
électronique sensible.
Veiller à ce que ce poste de soudage soit posé et mis à la terre
conformément à ce mode d’emploi.
En cas d’interférences après avoir pris les mesures précédentes, il
incombe à l’utilisateur de prendre des mesures supplémentaires telles que le déplacement du poste, l’utilisation de câbles blindés, l’utilisation de filtres de ligne ou la pose de protecteurs dans la zone de
travail.
LES CHAMPS MAGNÉTIQUES peuvent
affecter les stimulateurs cardiaques.
D Porteurs de stimulateur cardiaque, restez à distance.
D Les porteurs d’un stimulateur cardiaque doivent
d’abord consulter leur médecin avant de s’approcher des opérations de soudage à l’arc, de gougeage ou de soudage par points.
OM-357 Page 7
1-4. Principales normes de sécurité
Safety in Welding and Cutting, norme ANSI Z49.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL 33126
Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent
of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Recommended Safe Practice for the Preparation for Welding and Cutting of Containers That Have Held Hazardous Substances, norme AWS
F4.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL
33126
National Electrical Code, NFPA Standard 70, de la National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
de la Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
Règles de sécurité en soudage, coupage et procédés connexes, norme
CSA W117.2, de l’Association canadienne de normalisation, vente de
normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.
Safe Practices For Occupation And Educational Eye And Face Protection, norme ANSI Z87.1, de l’American National Standards Institute,
1430 Broadway, New York, NY 10018.
Cutting and Welding Processes, norme NFPA 51B, de la National Fire
Protection Association, Batterymarch Park, Quincy, MA 02269.
1-5. Information sur les champs électromagnétiques
Données sur le soudage électrique et sur les effets, pour l’organisme,
des champs magnétiques basse fréquence
Afin de réduire les champs électromagnétiques dans l’environnement
de travail, respecter les consignes suivantes :
L’extrait suivant est tiré des conclusions générales du document intitulé
Biological Effects of Power Frequency Electric & Magnetic Fields −
Background Paper, OTA−BP−E−53 (Washington DC : U.S. Government Printing Office, mai 1989), publié par le Office of Technology
Assessment du Congrès américain : «... il existe maintenant d’abondantes données scientifiques compilées à la suite d’expériences sur la
cellule ou d’études sur des animaux et des humains, qui montrent clairement que les champs électromagnétiques basse fréquence peuvent
avoir des effets sur l’organisme et même y produire des transformations. Même s’il s’agit de travaux de très grande qualité, les résultats
sont complexes. Cette démarche scientifique ne nous permet pas
d’établir un tableau d’ensemble cohérent. Pire encore, elle ne nous permet pas de tirer des conclusions finales concernant les risques
éventuels, ni d’offrir des conseils sur les mesures à prendre pour réduire sinon éliminer les risques éventuels». (Traduction libre)
1
OM-357 Page 8
2
3
4
5
Garder les câbles ensembles en les torsadant ou en les
attachant avec du ruban adhésif.
Mettre tous les câbles du côté opposé de l’opérateur.
Ne pas courber pas et ne pas entourer pas les câbles autour de
vous.
Garder le poste de soudage et les câbles le plus loin possible de
vous.
Relier la pince de masse le plus près possible de la zone de
soudure.
Consignes relatives aux stimulateurs cardiaques :
Les consignes mentionnées précédemment font partie de celles destinées aux personnes ayant recours à un stimulateur cardiaque. Veuillez
consulter votre médecin pour obtenir plus de détails.
SECTION 2 − INTRODUCTION
2-1. Specifications
Input Power
Rated Welding Output
Amperage
Range
Maximum
Open-Circuit
Voltage DC
250 A @ 30 Volts AC, 40%
Duty Cycle
Th
Three
Phase
Ph
Single Phase
200 A @ 28 Volts DC, 40%
Duty Cycle
250 A @ 30 Volts AC, 40%
Duty Cycle
200 A @ 28 Volts DC, 40%
Duty Cycle
5 300
5−300
90
5−300
90
Amperes Input at Rated Load Output 60 Hz
230 V
460 V
KVA
KW
26.3
*.27
17.9
*.15
14.2
*.09
10.5
*.04
20.5
*.27
13.4
*.15
8.4
*.09
7.6
*.04
62.6
*.33
32.2
*.18
14.8
*.10
10.4
*.07
44
*.33
25.8
*.18
11.9
*.1
8.1
*.07
*While idling
2-2. Duty Cycle and Overheating
Duty Cycle is percentage of 10 minutes that unit can weld at rated load
without overheating.
If unit overheats, output stops, a
Help message is displayed (see
Section 4-4), and cooling fan runs.
Wait fifteen minutes for unit to cool.
Reduce amperage or voltage, or
duty cycle before welding.
Y Exceeding duty cycle can
damage unit and void
warranty.
250 A @ 40% Duty Cycle For AC
200 A @ 40% Duty Cycle For DC
4 Minutes Welding
6 Minutes Resting
Overheating
0
A or V
15
Minutes
OR
Reduce Duty Cycle
sduty1 5/95 / SA-185 794
OM-357 Page 9
2-3. Volt-Ampere Curves
Volt-ampere curves show minimum and maximum voltage and
amperage output capabilities of
unit. Curves of other settings fall between curves shown.
SA-185 793 / SA-186 294
OM-357 Page 10
2-4. Selecting a Location
24 in
(610 mm)
Dimensions And Weight
90 lb (40.7 kg)
17 in
(432 mm)
12-1/2 in
(318 mm)
Movement
1
1
Y Do not move or operate unit
where it could tip.
Lifting Handles
Use handles to lift unit.
2
Hand Cart
Use cart or similar device to move
unit.
1
3
2
Rating Label
Use rating label to determine input
power needs.
4
Line Disconnect Device
Locate unit near correct input
power supply.
Y Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
Location
4
18 in
(460 mm)
3
18 in
(460 mm)
loc_2 3/96 - ST-801 708-A
OM-357 Page 11
2-5. Weld Output Terminals and Selecting Cable Sizes
Total Cable (Copper) Length In Weld Circuit Not Exceeding
100 ft (30 m) Or Less
Weld Output
Terminals
Electrode
Work
150 ft
(45 m)
200 ft
(60 m)
250 ft
(70 m)
300 ft
(90 m)
350 ft
(105 m)
400 ft
(120 m)
Welding
Amperes
10 − 60%
Duty
Cycle
60 − 100%
Duty Cycle
100
4
4
4
3
2
1
1/0
1/0
150
3
3
2
1
1/0
2/0
3/0
3/0
200
3
2
1
1/0
2/0
3/0
4/0
4/0
250
2
1
1/0
2/0
3/0
4/0
2-2/0
2-2/0
300
1
1/0
2/0
3/0
4/0
2-2/0
2-3/0
2-3/0
350
1/0
2/0
3/0
4/0
2-2/0
2-3/0
2-3/0
2-4/0
10 − 100% Duty Cycle
*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. Contact your
distributor for the mm2 equivalent weld cable sizes.
NOTE: For proper installation of gas hose, the use of a quick connect torch (such as Weldcraft QWP-17 or QWP-20), is recommened.
S-0007E
2-6. Remote 14 Receptacle Information
Socket*
ST-801 708-A
Socket Information
A
24 volts ac. Protected by circuit breaker CB2.
B
Contact closure to A completes 24 volts ac
contactor control circuit.
C
Output to remote control; 0 to +10 volts dc output
to remote control.
D
Remote control circuit common.
E
0 to +10 volts dc input command signal from
remote control.
M
Remote process.
F
Current feedback; +1 volt dc per 100 amperes.
H
Voltage feedback; +1 volt dc per 10 output
receptacle volts.
G
Circuit common for 24 volts ac circuits.
K
Chassis common.
24 VOLTS AC
A
B
K
J
I
H
C L N
D M
G
E F
REMOTE
OUTPUT
CONTROL
A/V
AMPERAGE
VOLTAGE
GND
*The remaining sockets are not used.
OM-357 Page 12
2-7. 115 Volts AC Duplex Receptacle (Optional) and Power Switch Location
1
1
115 V 10 A AC Receptacle
Power is shared between duplex
receptacle and Remote 14 receptacle (see Section 2-6).
2
2
Power On/Off Switch
ST-801 866
2-8. Electrical Service Guide
NOTE
Actual input voltage cannot exceed ± 15% of indicated required input voltage. If
actual input voltage is outside of this range, no output is available.
Three-Phase
Single-Phase
230
460
230
460
AC
26.5
17.9
62.6
32.2
DC
20.5
13.4
44
25.8
Max Recommended Standard Fuse Or Circuit Breaker
Rating In Amperes
50
25
100
50
Min Input Conductor Size In AWG/Kcmil
10
14
8
10
104 (32)
165 (50)
90 (27)
241 (74)
10
14
8
10
Input Voltage
Input Amperes At Rated Output
Max Recommended Input Conductor Length In Feet
(Meters)
Min Grounding Conductor Size In AWG/Kcmil
Reference: 1996 National Electrical Code (NEC).
S-0092J
OM-357 Page 13
2-9. Connecting Input Power
Check input voltage available at
site.
Tools Needed:
1
3/8 in
3/8 in
2
Input And Grounding
Conductors
Line Disconnect Device
See Section 2-8.
For single-phase operation:
3
3
1
4
5
6
Black And White Input
Conductor
Red Input Conductor
Insulation Sleeving
Electrical Tape
Insulate and isolate red conductor
as shown.
Y Always connect green wire
to supply grounding terminal, never to a line terminal.
For three-phase operation:
2
Connect black, white, and red wires
(L1, L2, L3) to line terminals.
2
Y Always connect green wire
to supply grounding terminal, never to a line terminal.
L1
L2
L1
L3
L2
Green
Green
1
1
Y Always connect grounding
conductor first.
= GND/PE
1
3
4
Green
1
6
5
input_2 3/96 - ST-801 709-A
OM-357 Page 14
SECTION 3 − OPERATION
3-1. Controls
1
2
3
4
5
6
13
12
7
8
11
1
10
AC Frequency Control
Range is 20 to 250 hertz. For most applications, increasing frequency improves arc stability.
2
Balance/DIG Control
Control functions as a balance control for
GTAW (TIG) process, and in the DIG mode for
SMAW (STICK) process, depending on
position of Process control.
Balance Mode:
See Section 3-2.
DIG Mode:
When set lower, short-circuit amperage at low
arc voltage is the same as normal welding amperage.
When set higher, short-circuit amperage is increased at low arc voltage to help with arc starting and making overhead or vertical welds, as
well as to reduce sticking while welding.
3
Voltmeter (see Section 3-3)
Voltmeter displays voltage (to the nearest 0.1
V) at the weld output terminals, but not necessarily the welding arc due to cable resistance,
poor connections, etc.
4
Ammeter (see Section 3-3)
14
Ref. ST-187 198
9
Use ammeter to preset amperage. Meter displays weld amperage output of unit when welding.
Selecting any GTAW (TIG) position enables
the gas valve, which is disabled when SMAW
(Stick) position is selected.
5
10 Sequence Control
Amperage Adjustment Control
Turn control clockwise to increase amperage
from 5 to 300 amps.
6
Output Control Switch
See Section 3-4.
7
Amperage Control Switch
For front panel control, place switch in Panel
position.
For remote control, make connections to
remote 14 receptacle, and place switch in
Remote 14 position.
8
Trigger Hold
To start weld, press and release gun trigger
within three seconds after an arc has been
struck. To end weld, press and release gun trigger. If gun trigger is not released within 3 seconds, unit switches to standard trigger control
operation.
9
Process Control
Use control to select either of the GTAW (TIG)
welding process and polarity, or the SMAW
(Stick) welding process.
See Section 3-5.
11 Start A (Amperage) Control
Use control to select a starting amperage that
is different from the weld amperage.
12 Start t (Amperage Time) Control
Use control to select length of time in seconds
that amperage remains at start amperage before changing to weld amperage.
For example, to select start amperage of 300 A
for 3 seconds and weld amperage of 200 A: Set
Start A amperage control to 300 A, set Start t
time control to 3 seconds, and set front panel
or remote amperage control to 200 A.
13 Crater Control
Control sets length of time in seconds to taper
weld output from weld amperage setting to 0 A
.
14 Postflow Control
Control sets length of time in seconds gas
flows after the welding stops.
OM-357 Page 15
3-2. AC/Balance Control
Balance Control:
Control changes the ac output
square wave.
Balance Control Waveform Examples
Max Penetration
At 20 Hz
1% Electrode
Positive
99% Electrode
Negative
100
Max Penetration
At 250 Hz
10% Electrode
Positive
90% Electrode
Negative
100
Max Cleaning At
All Hz
50% Electrode
Positive
50% Electrode
Negative
0
3-3. Meter Function
Mode
È
È
È
È
È
ÈÈÈÈ
ÈÈÈÈ
ÈÈÈ
ÈÈÈÈ
ÈÈÈÈÈÈ
ÈÈ
È
ÈÈ
È ÈÈ
ÈÈ
ÈÈÈ
ÈÈÈ
ÈÈÈ
ÈÈÈ
ÈÈÈÈÈÈ
ÈÈÈ
ÈÈÈ
ÈÈ
ÈÈÈ
ÈÈÈ
ÈÈ
ÈÈ
ÈÈ
ÈÈ
ÈÈ ÈÈ
ÈÈ
Meter Reading At Idle
V
85
V
A
24.5
85
Actual Volts (OCV)
Preset Amps
Actual Volts
Actual Amps
V
A
V
A
7.0
Lift On
85
10.3
85
Actual Volts
Preset Amps
Actual Volts
Actual Amps
V
A
V
A
Blank
Preset Amps
Actual Volts
Actual Amps
V
A
V
A
Blank
Preset Amps
Actual Volts
Actual Amps
V
A
V
A
Blank
Preset Amps
85
HF Remote
85
Lift Remote
85
Remote
10.3
85
10.3
85
24.5
85
Actual Volts
Actual Amps
3-4. Output Switch Settings
Output Switch Setting
Process
Output On/Off Control
On
GTAW (TIG)/SMAW (Stick)
Electrode Hot
Lift On
GTAW (TIG) With Lift-Arc Start − See Section
3-6
Electrode Hot
HF Remote
GTAW (TIG) With HF Start − See Section 3-6
At Remote 14
Lift Remote
GTAW (TIG)
At Remote 14
Remote
GTAW (TIG)/SMAW (Stick)
At Remote 14
OM-357 Page 16
deeper
cleaning
Meter Reading While Welding
A
80.0
On
Adjust
setting
for
penetration or more
action.
3-5. Sequence Control
Control Position
Allows These Controls To Be Functional
For The Following Processes
SMAW (Stick)/GTAW (TIG)
Stick
Off
Postflow t − 0-50 Seconds
TIG
Start t (Time) − 0-15 Seconds
Start A (Amperage0 − 0-300 Amps
Stick/TIG
Postflow − 0-50 Seconds
TIG
Crater
Crater t − 0-15 Seconds
Postflow t − 0-50 Seconds
TIG
Start/Crater
Start t (Time) − 0-15 Seconds
Start A (Amperage) − 0-300 Amps
Crater t − 0-15 Seconds
Postflow − 0-50 Seconds
TIG
Start
3-6. Lift-Arc and HF TIG Start Procedures
With Output Switch in Lift On
position, start arc as follows:
1
2
1
“Touch”
1−2
Seconds
2
TIG Electrode
Workpiece
Touch tungsten electrode to workpiece at weld start point, hold
electrode to workpiece for 1-2
seconds, and slowly lift electrode.
An arc will form when electrode is
lifted.
Normal open-circuit voltage is not
present before tungsten electrode
touches workpiece; only a low
sensing voltage is present between
electrode and workpiece. The
solid-state output contactor does
not energize until after electrode is
touching workpiece. This allows
electrode to touch workpiece without overheating, sticking, or getting
contaminated.
With Output Switch in HF Remote
position, start arc as follows:
Do NOT Strike Like A Match!
High frequency turns on to help
start arc when contactor is energized. High frequency turns off
when arc is started, and turns on
whenever arc is broken to help
restart arc.
Ref. ST-156 279
OM-357 Page 17
SECTION 4 − MAINTENANCE AND TROUBLESHOOTING
4-1. Routine Maintenance
Y Disconnect power before maintaining.
3 Months
Replace
unreadable
labels.
Clean and
tighten weld
terminals.
Replace damaged
gas hose.
Repair or replace cracked
cables and cords.
6 Months
Blow out inside. During heavy
service, clean monthly.
4-2. Overload Protection
1
Circuit Breaker CB1
CB1 protects 115 volts ac portion of
duplex receptacle and Remote 14
receptacle from overload.
2
Circuit Breaker CB2
CB2 protects 24 volts ac portion of
Remote 14 receptacle from
overload.
1
2
Press button to reset breaker.
ST-801 866
4-3. Blowing Out Inside of Unit
ST-801 708-A
Y Do not remove case when
blowing out inside of unit.
To blow out unit, direct airflow
through front and back louvers as
shown.
OM-357 Page 18
4-4. Voltmeter/Ammeter Help Displays
1
2
3
V
A
HE.L
P−1
V
A
HE.L
P−2
V
A
HE.L
P−3
. All directions are in reference to
the front of the unit. All circuitry
referred to is located inside the
unit.
1
2
5
6
V
A
HE.L
P−4
V
A
HE.L
P−5
V
A
HE.L
P−6
Help 2 Display
Indicates a malfunction in the thermal protection circuitry located on
the left side of the unit. Contact a
Factory Authorized Service Agent if
this display is shown.
3
Help 3 Display
Indicates the unit has overheated.
The unit has shut down to allow the
fan to cool it (see Section 2-2). Operation will continue when the unit
has cooled.
4
4
Help 1 Display
Indicates a malfunction in the primary power circuit. Contact a Factory Authorized Service Agent if this
display is shown.
Help 4 Display
Indicates that the input voltage is
too high and the unit has automatically shut down. Operation will continue when the voltage is within the
operating range (±15%). Have an
electrician check the input voltage if
this display is shown.
5
Help 5 Display
Indicates that the input voltage is
too low and the unit has automatically shut down. Operation will continue when the voltage is within the
operating range (±15%). Have an
electrician check the input voltage if
this display is shown.
6
Help 6 Display
Indicates a malfunction in the secondary power circuit of the unit.
Contact a Factory Authorized Service Agent if this display is shown.
OM-357 Page 19
4-5. Troubleshooting
Trouble
No weld output; unit completely
inoperative.
Remedy
Place line disconnect switch in On position (see Section 2-9).
Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section 2-9).
Check for proper input power connections (see Section 2-9).
No weld output; meter display On.
If using remote control, be sure process switch is in a position that provides output control at Remote
14 receptacle (see Section 3-1 as applicable).
Input voltage outside acceptable range of variation (see Section 2-8).
Check, repair, or replace remote control.
Unit overheated. Allow unit to cool with fan On (see Section 2-2).
Erratic or improper weld output.
Use proper size and type of weld cable (see Section 2-5).
Clean and tighten all weld connections.
No 115 volts ac output at duplex receptacle.
Reset circuit breaker CB1 (see Section 4-2).
No 24 volts ac output at Remote 14 receptacle.
Reset circuit breaker CB2 (see Section 4-2).
No high frequency.
Check fuse F1, and replace if necessary.
OM-357 Page 20
Notes
OM-357 Page 21
SECTION 5 − ELECTRICAL DIAGRAM
Figure 5-1. Circuit Diagram
OM-357 Page 22
SD-183 036-B
OM-357 Page 23
SECTION 6 − HIGH FREQUENCY
6-1. Welding Processes Requiring High Frequency
1
High-Frequency Voltage
TIG − helps arc jump air gap
between torch and workpiece and/
or stabilize the arc.
1
Work
TIG
high_freq 12/96 − S-0693
6-2. Incorrect Installation
Weld Zone
11, 12
50 ft
(15 m)
10
14
9
8
7
3
2
13
1
4
Sources of Direct High-Frequency
Radiation
1 High-Frequency Source (welding
power source with built-in HF or
separate HF unit)
2 Weld Cables
3 Torch
4 Work Clamp
5 Workpiece
6 Work Table
5
6
Sources of Conduction of High
Frequency
7 Input Power Cable
8 Line Disconnect Device
9 Input Supply Wiring
Sources of Reradiation of High
Frequency
10 Ungrounded Metal Objects
11 Lighting
12 Wiring
13 Water Pipes and Fixtures
14 External Phone and Power Lines
S-0694
OM-357 Page 24
6-3. Correct Installation
7
Weld Zone
3
50 ft
(15 m)
50 ft
(15 m)
5
1
6
2
8
4
8
Ground all metal objects and all wiring in
welding zone using
#12 AWG wire.
Nonmetal
Building
Ground
workpiece
if required
by codes.
9
Metal Building
8
8
11
10
Ref. S-0695 / Ref. S-0695
1
High-Frequency Source (welding
power source with built-in HF or
separate HF unit)
Ground metal machine case, work output
terminal, line disconnect device, input
supply, and worktable.
2 Center Point of Welding Zone
Midpoint between high-frequency source
and welding torch.
3 Welding Zone
A circle 50 ft (15 m) from center point in all
directions.
4 Weld Output Cables
Keep cables short and close together.
5
Conduit Joint Bonding and Grounding
Electrically join (bond) all conduit sections
using copper straps or braided wire. Ground
conduit every 50 ft (15 m).
6
Water Pipes and Fixtures
Metal Building Requirements
9
Metal Building Panel Bonding Methods
Bolt or weld building panels together, install
copper straps or braided wire across seams,
and ground frame.
Ground water pipes every 50 ft (15 m).
10 Windows and Doorways
7
Cover all windows and doorways with
grounded copper screen of not more than
1/4 in (6.4 mm) mesh.
External Power or Telephone Lines
Locate high-frequency source at least 50 ft
(15 m) away from power and phone lines.
8
Grounding Rod
Consult the National Electrical Code for
specifications.
11 Overhead Door Track
Ground the track.
OM-357 Page 25
22
21
20
SECTION 7 − PARTS LIST
19
. Hardware is common and
31
PC1
PC8
39
39
1
20
37
38
40
36
41
2
35
3
34
33
FIG. 6−2 − 42
32
4
5
6
7
30−PC3
8
9
10
29
11
28
27
PC2
12
13
14
15
16
26
17
25
18
24
23
not available unless listed.
Figure 7-1.Main Assembly
OM-357 Page 26
ST-801 870-A
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 7-1. Main Assembly
. . . 1 . . . . . . . . . . . . . . . 126 416 . . HANDLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 2 . . . . . . . . . . . . . . . 126 415 . . CLAMP, saddle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 3 . . . . . . . . . . . . . . . 138 442 . . LABEL, caution falling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 4 . . . . . . . . . . . . . . +175 148 . . WRAPPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 175 256 . . INSULATOR, side RH & LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 5 . . . . . . . . . . . . . . . 134 327 . . LABEL, warning general precautionary . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 6 . . . . . PC8 . . . . . 182 188 . . CIRCUIT CARD ASSEMBLY, clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . PLG21 . . . . 183 597 . . PLUG, w/leads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . PLG22 . . . . 115 093 . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 7 . . . . . . . . . . . . . . . 183 613 . . INSULATOR, PC card clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 8 . . . . . . . . . . . . . . . 182 498 . . BRACKET, mtg PC card clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 9 . . . . . PC1 . . . . . 186 800 . . CIRCUIT CARD ASSEMBLY, control . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG2 . . . . 115 091 . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG3 . . . . 183 086 . . PLUG, w/leads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG4 . . . . 184 770 . . PLUG, w/leads fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . PLG5,15,16 . . 175 026 . . PLUG, w/leads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG7 . . . . 183 596 . . PLUGS, w/leads secondary gate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG8 . . . . 115 092 . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG9 . . . . 183 595 . . PLUG, w/leads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . PLG10 . . . . 115 094 . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 10 . . . . . . . . . . . . . ♦187 461 . . BRACKET, mtg aux transformer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 11 . . . . . T2 . . . . . . 182 846 . . TRANSFORMER, control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 11 . . . . . T2 . . . . ♦174 981 . . TRANSFORMER, control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . RC10 . . . . 115 094 . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 12 . . . . . GS1 . . . . . 133 873 . . VALVE, 24VDC 2way . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 13 . . . . . . . . . . . . . ♦604 176 . . RECEPTACLE, str dx grd 2P 3W 15A . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 14 . . . . . CB1 . . . ♦083 432 . . CIRCUIT BREAKER, 1P 10A 250VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 15 . . . . . CB2 . . . . . 083 432 . . CIRCUIT BREAKER, 1P 10A 250VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 16 . . . . . . . . . . . . . . . 605 227 . . NUT, .750-14 knurled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 17 . . . . . . . . . . . . . . . 182 205 . . PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 18 . . . . . . . . . . . . . . . . . . . . . . . . . . PLATE, identification rear (order by model & serial number) . . . . . . . . . .
. . . 19 . . . . . . . . . . . . . ♦175 282 . . COVER, receptacle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 20 . . . . . . . . . . . . . . . 175 138 . . BOX, louver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 21 . . . . . . . . . . . . . . . 182 561 . . CABLE, pwr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 22 . . . . . . . . . . . . . . . 175 213 . . BUSHING, strain relief .472/.787 ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 23 . . . . . . . . . . . . . . . 182 445 . . NUT, stl locking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 24 . . . . . . . . . . . . . . . 176 226 . . INSULATOR, switch power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 25 . . . . . S1 . . . . . . 128 756 . . SWITCH, tgl 3PST 40A 600VAC (Power Switch) . . . . . . . . . . . . . . . . . . .
. . . 26 . . . . . PC2 . . . . . 183 620 . . CIRCUIT CARD, assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 176 879 . . SCREW, M5−.8−2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . PLG13 . . . . 131 204 . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . PLG14 . . . . 183 086 . . PLUG, w/leads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 179 626 . . BUS BAR, interconnecting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 27 . . . . . . . . . . . . . . +175 132 . . BASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 126 026 . . LABEL, warning electric shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 28 . . . . . . . . . . . . . . . 173 693 . . FOOT, mtg unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 29 . . . . . . . . . . . . . . . 176 736 . . SCREW, mtg foot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 30 . . . . . PC3 . . . . . 187 712 . . CIRCUIT CARD, front panel (consisting of) . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . DD1-6 . . . . 186 914 . . . . LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . R5 . . . . . . 176 537 . . . . POTENTIOMETER, CP 1/T 2W 10K . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . R81-86 . . . . 182 771 . . . . POTENTIOMETER, CP 1/T .5W 10K . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . R84 . . . . . 183 316 . . . . POTENTIOMETER, CP 1/T .5W 2.5meg . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . SW1 . . . . . 173 551 . . . . SWITCH, rotary 2posn 1P 6A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . SW2 . . . . . 175 954 . . . . SWITCH, rotary 5posn 1P 6A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . SW3 . . . . . 182 772 . . . . SWITCH, rotary 6posn 1P 6A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . SW4 . . . . . 183 482 . . . . SWITCH, rotary 4posn 1P 6A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . SW5 . . . . . 125 939 . . . . SWITCH, tgl DPDT .5VA 28VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG11 . . . . 183 088 . . RECEPTACLE, w/leads & plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 31 . . . . . FM . . . . . 175 084 . . MOTOR, fan 24VDC 3000RPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
2
2
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
18
1
1
1
1
1
4
4
1
6
1
5
1
1
1
1
1
1
1
1
OM-357 Page 27
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 7-1. Main Assembly
...
...
...
...
...
...
...
...
...
...
...
32
33
34
35
36
37
38
39
40
41
42
. . . . . . . . . . . . . . . 186 945 . .
..........................
. . . . . RC1 . . . . . 188 186 . .
. . . . . . . . . . . . . . . 174 992 . .
. . . . . . . . . . . . . . . 185 703 . .
. . . . . . . . . . . . . . . 175 855 . .
. . . . . . . . . . . . . . . 187 235 . .
. . . . C7,8 . . . . . 186 543 . .
. . . . . . . . . . . . . . . 183 332 . .
. . . . . . . . . . . . . . . 174 991 . .
. . . . . . . . . . . . . . . . Fig 6-2 . .
PANEL, front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NAMEPLATE, (order by model and serial number) . . . . . . . . . . . . . . . . .
CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KNOB, pointer .840dia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RECEPTACLE, twist lock assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DOOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RECEPTACLE, female . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CAPACITOR, cer disc .1uf 500VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KNOB, pointer .570 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KNOB, pointer 1.250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WINDTUNNELS w/COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
4
2
1
1
2
6
1
1
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
♦Optional
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
. Hardware is common and
not available unless listed.
3
1
4
9
2
8
5
6
10
7
14
11
12
13
33
32
31
15
30
16
29
28
27
26
17
25
18
24
19
23
20
22
21
ST-801 871-A
Figure 7-2.Windtunnels w/Components
OM-357 Page 28
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 7-2. Windtunnels w/Components (Fig 6-1 Item 42)
. . . 1 . . . C11,12 . . . . 185 424 . . CAPACITOR, filter assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 2 . . . . C9,10 . . . . 164 812 . . CAPACITOR, polyp met film 1MF 600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 3 . . . . . HD1 . . . . . 182 918 . . TRANSDUCER, current 400A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 4 . . . . . . . . . . . . . . +182 206 . . WINDTUNNEL, LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . 153 718 . . LABEL, warning exploding parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . . . . . . . . . . . . . . . . . . 126 026 . . LABEL, warning electric shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 5 . . . R1,C5,6 . . . 175 194 . . RESISTOR/CAPACITOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 6 . . . . D1,2 . . . . . 185 775 . . KIT, diode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 7 . . . . . . . . . . . . . . . 182 208 . . HEAT SINK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 8 . . . . . T3 . . . . . . 182 667 . . TRANSFORMER, coupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 9 . . . . . . . . . . . . . . . 183 073 . . INSULATOR, PC card HF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 10 . . . . . . . . . . . . . . . 182 499 . . ENCLOSURE, HF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 11 . . . . . . . . . . . . . . . 182 806 . . BRACKET, mtg contactor/capacitor/PC board . . . . . . . . . . . . . . . . . . . . . . 1
. . . 12 . . . . C3,4 . . . . . 174 980 . . CAPACITOR, elctlt 2700uf 420VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 13 . . . W1,2,2A . . . 175 082 . . CONTACTOR, def prp 40A 7P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . 173 763 . . STAND-OFF, No. 10-32 x 1.418 lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 14 . . . . . T1 . . . . . . 183 014 . . TRANSFORMER, HF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 15 . . . . . L2 . . . . . . 183 009 . . STABILIZER, output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 16 . . . . . L1 . . . . . . 187 522 . . INDUCTOR, input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 17 . . . . . C1 . . . . . . 186 549 . . CAPACITOR, polyp .27uf 1000VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 18 . . . . . . . . . . . . . . . 025 248 . . STAND-OFF, insul .250-20 x 1.250 lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 19 . . . . . CT1 . . . . . 175 199 . . TRANSFORMER, current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 20 . . . . . . . . . . . . . . . 177 547 . . BUSHING, snap-in CT-mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 21 . . . . . . . . . . . . . . . 175 140 . . BRACKET, DI-DT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 22 . . . . . . . . . . . . . . . 181 197 . . GASKET, DI-DT rubber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 23 . . . . . L3,4 . . . . . 175 482 . . COIL, DI-DT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 24 . . . . . . . . . . . . . . . 109 056 . . CORE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 25 . . . . . . . . . . . . . . +187 460 . . WINDTUNNEL, RH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 26 . . . . . . . . . . . . . . . 141 690 . . GROMMET, scr No. 8/10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . 27 . . . . . PC7 . . . . . 186 807 . . CIRCUIT CARD, HF (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . F1 . . . . . . 012 633 . . . . FUSE, mintr gl 1A 250V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG19 . . . . 115 092 . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG20 . . . . 183 595 . . PLUG, w/leads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 28 . . . . . SR1 . . . . . 179 629 . . KIT, diode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 29 . PM1,2/PC4,5 . 179 628 . . KIT, transistor IGBT module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . RT1,2 . . . . 173 632 . . THERMISTOR, NTC 30K ohm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 30 . . . . . . . . . . . . . . . 173 631 . . HEAT SINK, power module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 31 . PM3,4/PC6 . . 185 776 . . KIT, IGBT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG23 . . . . 183 596 . . PLUG, w,leads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 32 . . . . . . . . . . . . . . . 182 641 . . BUS BAR, diode IGBT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 33 . . . . . . . . . . . . . . . 182 642 . . BUS BAR, IGBT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-357 Page 29
OPTIONS AND ACCESSORIES
Control Options
PC-300 Pulsed GTAW (DC TIG)
Control
#042 297
Can be used with power sources
that have built-in high frequency, or
it can be used with an external
high-frequency unit. The control has
two internally switchable scales: a
0.5 − 20 pulses-per-second scale for
both inverter and non-inverter type
power sources, and a 10 – 300
pulses-per-second scale for inverter
power sources only.
Control includes 8 ft (2.4 m) inter
connecting cord and 115 VAC
power cord. Front panel controls
provide:
• Peak amperage adjustment
• Background amperage adjustment
• Pulses-per-second adjustment
(0.5-20 pulses-per-second scale
or
10–300
pulses-per-second scale)
• Percent-on-time control
• Amperage remote/panel control
• Output contactor on/off control
• Pulser on/off
• Power on/off
• Remote control receptacle (for
remote hand or foot controls)
Remote Controls
RFCS-14 Foot Control #043 554
Foot current and contactor control.
Includes 20 ft (6 m) cord and 14-pin
plug.
RHC-14 Hand Control #129 340
Miniature hand control for remote
current and contactor control.
Dimensions: 4 in (102 mm) x
4 in (102 mm) x 3-1/4 in (82 mm).
Includes 20 ft (6 m) cord and
14-pin plug.
RCC-14 Remote Contactor and
Current Control #151 086
14-pin plug rotary-motion fingertip
control fastens to TIG torch using
two Velcro straps. Includes 28 ft
(8.5 m) control cord.
RMSL-14 #129 337 14-pin plug
Momentary and maintained contact
rocker switch for contactor control.
Push forward for maintained contact
and back for momentary contact.
Includes 20 ft (6 m) cord.
Extension Cords for Remote
Controls
#122 973 25 ft (7.6 m)
#122 974 50 ft (15.2 m)
#122 975 75 ft (22.8 m)
14-pin plug to a 14-pin socket.
Cylinder Cart #042 537
Has adjustable handles and is
slanted for convenient access to
power source front panel controls.
Carries two 160 lb (72.6 kg) gas
cylin ders, or one gas cylinder and
one Watermate coolant system for
GTAW (TIG) welding. Can also be
used with the Maxtron or XMT
inverter power supplies. Also accom
modates Radiator, Watermate, or
Coolmate coolant systems.
Universal Carrying Cart and
Cylinder Rack #042 934
Accommodates power source, plus
gas cylinder up to 56 in (142.2 cm)
high measuring 6 to 9 in (15.2 to
22.8 cm) in diameter. Also provides
storage for auxiliary items such as
electrodes, helmets, gloves, etc.
Can also be used with XMT,
Dynasty, Econotig, Maxstar
Series and Millermatic 130 power
sources.
Water Coolant Systems
For use with water-cooled guns.
Refer to Literature Index No. AY/7.2.
Coolmatet 3 Cooling System
#043 007
Coolmatet 4 Cooling System
#042 288
Watermatet 1A Cooling System
#042 495
See Literature Index No. AY/7.2.
1/95
Effective January 1, 1997
(Equipment with a serial number preface of “KH” or newer)
This limited warranty supersedes all previous Miller warranties and is exclusive with no other
guarantees or warranties expressed or implied.
LIMITED WARRANTY − Subject to the terms and conditions
below, Miller Electric Mfg. Co., Appleton, Wisconsin,
warrants to its original retail purchaser that new Miller
equipment sold after the effective date of this limited warranty
is free of defects in material and workmanship at the time it is
shipped by Miller. THIS WARRANTY IS EXPRESSLY IN
LIEU OF ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING
THE
WARRANTIES OF
MERCHANTABILITY AND FITNESS.
Within the warranty periods listed below, Miller will repair or
replace any warranted parts or components that fail due to
such defects in material or workmanship. Miller must be
notified in writing within thirty (30) days of such defect or
failure, at which time Miller will provide instructions on the
warranty claim procedures to be followed.
Miller shall honor warranty claims on warranted equipment
listed below in the event of such a failure within the warranty
time periods. All warranty time periods start on the date that
the equipment was delivered to the original retail purchaser,
or one year after the equipment is sent to a North American
distributor or eighteen months after the equipment is sent to
an International distributor.
1.
2.
Warranty Questions?
Call
1-800-4-A-MILLER
for your local
Miller distributor.
3.
5 Years Parts − 3 Years Labor
*
Original main power rectifiers
*
Inverters (input and output rectifiers only)
3 Years — Parts and Labor
*
Transformer/Rectifier Power Sources
*
Plasma Arc Cutting Power Sources
*
Semi-Automatic and Automatic Wire Feeders
*
Inverter Power Supplies
*
Intellitig
*
Robots
*
Engine Driven Welding Generators
(NOTE: Engines are warranted separately by the
engine manufacturer.)
1 Year — Parts and Labor
*
Motor Driven Guns (w/exception of Spoolmate 185)
*
Process Controllers
*
Positioners and Controllers
*
Automatic Motion Devices
*
Orbital Weld Heads
*
IHPS Power Sources
*
Water Coolant Systems
*
HF Units
*
Grids
*
Spot Welders
*
Load Banks
*
SDX Transformers
*
Miller Cyclomatic Equipment
*
Running Gear/Trailers
*
Plasma Cutting Torches (except APT, ZIPCUT &
PLAZCUT Models)
*
Deutz Engines (outside North America)
*
Field Options
(NOTE: Field options are covered under True Blue
for the remaining warranty period of the product they
are installed in, or for a minimum of one year —
whichever is greater.)
4.
6 Months — Batteries
5.
90 Days — Parts and Labor
*
MIG Guns/TIG Torches
*
APT, ZIPCUT & PLAZCUT Model Plasma Cutting
Torches
*
Remote Controls
*
Accessory Kits
*
Replacement Parts (No labor)
*
Spoolmate 185
Miller’s True Blue Limited Warranty shall not apply to:
1.
Items furnished by Miller, but manufactured by others,
such as engines or trade accessories. These items are
covered by the manufacturer’s warranty, if any.
2.
Consumable components; such as contact tips, cutting
nozzles, contactors, brushes, slip rings, relays or parts
that fail due to normal wear.
3.
Equipment that has been modified by any party other
than Miller, or equipment that has been improperly
installed, improperly operated or misused based upon
industry standards, or equipment which has not had
reasonable and necessary maintenance, or equipment
which has been used for operation outside of the
specifications for the equipment.
MILLER PRODUCTS ARE INTENDED FOR PURCHASE
AND USE BY COMMERCIAL/INDUSTRIAL USERS AND
PERSONS TRAINED AND EXPERIENCED IN THE USE
AND MAINTENANCE OF WELDING EQUIPMENT.
In the event of a warranty claim covered by this warranty, the
exclusive remedies shall be, at Miller’s option: (1) repair; or
(2) replacement; or, where authorized in writing by Miller in
appropriate cases, (3) the reasonable cost of repair or
replacement at an authorized Miller service station; or (4)
payment of or credit for the purchase price (less reasonable
depreciation based upon actual use) upon return of the
goods at customer’s risk and expense. Miller’s option of
repair or replacement will be F.O.B., Factory at Appleton,
Wisconsin, or F.O.B. at a Miller authorized service facility as
determined by Miller. Therefore no compensation or
reimbursement for transportation costs of any kind will be
allowed.
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE
FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF
PROFIT), WHETHER BASED ON CONTRACT, TORT OR
ANY OTHER LEGAL THEORY.
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN
AND ANY IMPLIED WARRANTY, GUARANTY OR
REPRESENTATION AS TO PERFORMANCE, AND ANY
REMEDY FOR BREACH OF CONTRACT TORT OR ANY
OTHER LEGAL THEORY WHICH, BUT FOR THIS
PROVISION, MIGHT ARISE BY IMPLICATION,
OPERATION OF LAW, CUSTOM OF TRADE OR COURSE
OF DEALING, INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR PARTICULAR
PURPOSE, WITH RESPECT TO ANY AND ALL
EQUIPMENT FURNISHED BY MILLER IS EXCLUDED
AND DISCLAIMED BY MILLER.
Some states in the U.S.A. do not allow limitations of how long
an implied warranty lasts, or the exclusion of incidental,
indirect, special or consequential damages, so the above
limitation or exclusion may not apply to you. This warranty
provides specific legal rights, and other rights may be
available, but may vary from state to state.
In Canada, legislation in some provinces provides for certain
additional warranties or remedies other than as stated
herein, and to the extent that they may not be waived, the
limitations and exclusions set out above may not apply. This
Limited Warranty provides specific legal rights, and other
rights may be available, but may vary from province to
province.
Owner’s Record
Please complete and retain with your personal records.
Model Name
Serial/Style Number
Purchase Date
(Date which equipment was delivered to original customer.)
Distributor
Address
City
State
Zip
Resources Available
Always provide Model Name and Serial/Style Number.
Contact your Distributor for:
To locate distributor nearest you call
1-800-4-A-Miller.
Welding Supplies and Consumables
Options and Accessories
Personal Safety Equipment
Miller Electric Mfg. Co.
Service and Repair
Replacement Parts
Training (Schools, Videos, Books)
Owner’s Manuals
Technical Manuals (Servicing Information
and Parts)
Circuit Diagrams
Welding Process Handbooks
Contact the Delivering Carrier
for:
File a claim for loss or damage during shipment.
For assistance in filing or settling claims,
contact your distributor and/or equipment
manufacturer’s Transportation Department.
PRINTED IN USA
 1997 Miller Electric Mfg. Co.
An Illinois Tool Works Company
1635 West Spencer Street
Appleton, WI 54914 USA
International Headquarters−USA
Phone: 920-734-9821
USA & Canada FAX: 920-735-4134
International FAX: 920-735-4125
European Headquarters −
United Kingdom
Phone: 44 (0) 1625-525556
FAX: 44 (0) 1625-537553
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF