Miller FILTAIR CAPTURE 5 FUME EXTRACTOR User manual

Miller FILTAIR CAPTURE 5 FUME EXTRACTOR User manual
OM-260 545G
2014−12
Processes
Multiprocess Welding
Description
Mobile Weld Fume Extractor
FILTAIR
)
Capture 5 Fume Extractor
Read And Save These Instructions
File: Accessory
Visit our website at
www.MillerWelds.com
From Miller to You
Thank you and congratulations on choosing Miller. Now you can get
the job done and get it done right. We know you don’t have time to do
it any other way.
That’s why when Niels Miller first started building arc welders in 1929,
he made sure his products offered long-lasting value and superior
quality. Like you, his customers couldn’t afford anything less. Miller
products had to be more than the best they could be. They had to be the
best you could buy.
Today, the people that build and sell Miller products continue the
tradition. They’re just as committed to providing equipment and service
that meets the high standards of quality and value established in 1929.
This Owner’s Manual is designed to help you get the most out of your
Miller products. Please take time to read the Safety precautions. They
will help you protect yourself against potential hazards on the worksite.
We’ve made installation and operation quick
and easy. With Miller you can count on years
of reliable service with proper maintenance.
And if for some reason the unit needs repair,
there’s a Troubleshooting section that will
help you figure out what the problem is. The
Miller is the first welding parts list will then help you to decide the
equipment manufacturer in exact part you may need to fix the problem.
the U.S.A. to be registered to
the ISO 9001 Quality System Warranty and service information for your
Standard.
particular model are also provided.
Miller Electric manufactures a full line
of welders and welding related equipment.
For information on other quality Miller
products, contact your local Miller distributor to receive the latest full
line catalog or individual specification sheets. To locate your nearest
distributor or service agency call 1-800-4-A-Miller, or visit us at
www.MillerWelds.com on the web.
Mil_Thank 2009−09
Working as hard as you do
− every power source from
Miller is backed by the most
hassle-free warranty in the
business.
TABLE OF CONTENTS
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Fume Extraction Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Arc Welding And Plasma Cutting Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. California Proposition 65 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-6. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-7. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 − MESURES DE SÉCURITÉ −EXTRACTION DES FUMÉES − À LIRE AVANT UTILISATION
2-1. Symboles utilisés . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2. Dangers en matière d’extraction des fumées . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3. Dangers du soudage à l’arc et du coupage au plasma . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-4. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance . . . . .
2-5. Proposition californienne 65 Avertissements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-6. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-7. Informations relatives aux CEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 − DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1. Additional Safety Symbols And Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2. Miscellaneous Symbols And Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 4 − SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. Serial Number And Rating Label Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3. Fume Extractor Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-4. Extraction Arm Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-5. Fume Capture Zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 5 − INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-1. Selecting A Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2. Tipping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-3. Lifting Extraction Arm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-4. Installing Extraction Arm Base Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-5. Connecting To Compressed Air Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-6. Wiring Input Power Plug For Single-Phase Models (NEMA L6-30C) . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-7. Wiring Input Power Plug For Three-Phase Models (NEMA L16-20C Or L17-30C) . . . . . . . . . . . . . . .
5-8. Electrical Service Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-9. Connecting Single-Phase Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-10. Connecting Three-Phase Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 − OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-1. Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-2. Prestart Checklist (Before Welding) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 7 − USER SERVICING INSTRUCTIONS (MAINTENANCE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-2. Overload Protection On 230 Volt Single-Phase Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-3. Overload Protection On 460 Volt And 575 Volt Three-Phase Models . . . . . . . . . . . . . . . . . . . . . . . . . .
7-4. Cleaning Filter And Emptying Particle Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-5. Inspecting Filter And Spark Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-6. Adjusting Extraction Arm Joints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 8 − TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-1. Troubleshooting Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 9 − ELECTRICAL DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 10 − PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARRANTY
1
1
1
2
4
5
5
5
6
6
6
7
9
11
11
11
12
12
12
13
13
13
13
14
14
15
15
16
16
17
18
19
19
20
20
21
22
22
23
24
24
25
26
27
28
29
29
29
30
33
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING
fume 2014−04
7
Protect yourself and others from injury — read, follow, and save these important safety precautions and operating instructions.
1-1. Symbol Usage
DANGER! − Indicates a hazardous situation which, if
not avoided, will result in death or serious injury. The
possible hazards are shown in the adjoining symbols
or explained in the text.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury. The possible
hazards are shown in the adjoining symbols or explained in the text.
NOTICE − Indicates statements not related to personal injury.
Indicates special instructions.
This group of symbols means Warning! Watch Out! ELECTRIC
SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult symbols and related instructions below for necessary actions to avoid the
hazards.
1-2. Fume Extraction Hazards
The symbols shown below are used throughout this manual
to call attention to and identify possible hazards. When you
see the symbol, watch out, and follow the related instructions
to avoid the hazard. The safety information given below is
only a summary of the more complete safety information
found in the Safety Standards listed in Section 1-6. Read and
follow all Safety Standards.
Only qualified persons should install, operate, maintain, and
repair this unit.
During operation, keep everybody, especially children, away.
FUME EXTRACTOR MISUSE can be hazardous.
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health. Combustible materials may ignite and cause
fire and explosion.
Read and follow these instructions and the safety labels
carefully. The fume extractor helps protect the user from specific
airborne contaminants but must be used correctly to be fully
effective. Have an industrial hygienist test the air in your facility to
ensure the fume extractor provides adequate protection from
contaminants in your environment. If you have questions about the
extractor, see equipment label and consult your Safety Director
and a certified Industrial Hygienist.
Follow all applicable ANSI, OSHA, CSA, UL, and other regulatory
guidelines pertaining to the use of fume extractors and the
recirculation of filtered air.
Portions of fume collection equipment, including the clean- and
dirty-air plenums, may be considered OSHA Confined Spaces.
Refer to the appropriate OSHA regulations to determine if a
specific installation is a confined space and if a permit program is
required.
Do not use the fume extractor without an approved and properly
installed spark guard unless the unit is designed and intended to be
used without one. Without the spark guard, welding sparks may
ignite a non-fire retardant filter or fume collected on the filter, or
damage the filter and allow unfiltered air into the breathing zone.
Do not allow sparks or any burning materials to enter the hood or
duct of the fume extractor.
Only use the fume extractor to extract weld fumes. Do not use the
fume extractor to extract hot gases (above 140°F/60°C) wood or
cement dust, engine exhaust, liquid vapors, explosive materials,
aggressive fumes (acid), fumes from burning objects, or fumes
from cleaning, cutting, gouging, grinding, painting, flame spraying,
sand blasting, or other non−welding operations.
Fumes from some welding operations may be combustible. Do not
install or operate fume extractor where combustible weld fumes
may be present unless a fire/and/or explosion protection system is
present that has been selected and approved by a qualified person
familiar with applicable codes and fire/explosion protection
systems.
Use the fume extractor only in atmospheres for which it is
recommended. Do not use the extractor where contaminant levels
are unknown or are immediately dangerous to life, or where the
contaminant levels exceed the fume extractor specifications.
Do not weld until you are sure the fume extractor is correctly
assembled and working properly.
Before each use, inspect the fume extractor for damage and verify
it operates properly.
Dangerous contaminants may not smell or be visible. Leave the
area immediately if you notice the following:
a. Breathing becomes difficult.
b. You experience dizziness, impaired vision, or eye, nose, or
mouth irritation.
c. The equipment is damaged.
d. Air flow decreases or stops.
e. If you think the equipment is not supplying adequate
protection.
Do not repair, modify, or disassemble the fume extractor or use
with parts or accessories not supplied by the manufacturer. Use
only approved components from the manufacturer.
Replace damaged or plugged filter. Allow cooling period before
inspecting or replacing filter, or cleaning particle tray and spark
guard. Do not wash or reuse filter, or clean filter by tapping or with
compressed air, unless specifically instructed by the manufacturer
in the Owner’s Manual (filter element may be damaged). Do not
breathe the particles collected by the fume extractor. Wear
approved safety equipment (respirator, gloves, long sleeve shirt)
when performing filter maintenance. Dispose of used filter element
and collected particles according to local, state, and federal
requirements.
Read and understand the Safety Data Sheets (SDSs) and the
manufacturer’s instructions for adhesives, coatings, cleaners,
consumables, coolants, degreasers, fluxes, and metals.
The fume extractor must be used with the extraction arm, hoses,
filter, and other components recommended by the manufacturer.
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shocks
or severe burns. The input power circuit and machine
internal circuits are also live when power is on.
Incorrectly installed or improperly grounded equipment is a hazard.
Do not touch live electrical parts.
Disconnect input power before installing or servicing this equipment. Lockout/tagout input power according to OSHA 29 CFR
1910.147 (see Safety Standards).
Properly install, ground, and operate this equipment according to
its Owner’s Manual and national, state, and local codes.
Always verify the supply ground − check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
grounded receptacle outlet.
Frequently inspect input power cord and ground conductor for
damage or bare wiring – replace immediately if damaged – bare
wiring can kill.
OM-260 545 Page 1
FALLING EQUIPMENT can injure.
Use equipment of adequate capacity to lift and
support unit.
If using lift forks to move unit, be sure forks are
long enough to extend beyond opposite side of
unit.
Keep equipment (cables and cords) away from moving vehicles
when working from an aerial location.
Follow the guidelines in the Applications Manual for the Revised
NIOSH Lifting Equation (Publication No. 94−110) when manually lifting heavy parts or equipment.
MOVING PARTS can injure.
Keep away from moving parts such as fans.
Keep all doors, panels, covers, and guards
closed and securely in place.
Have only qualified persons remove doors, panels, covers, or
guards for maintenance and troubleshooting as necessary.
Reinstall doors, panels, covers, or guards when maintenance is
finished and before reconnecting input power.
FIRE OR EXPLOSION hazard.
Do not install or place unit on, over, or near
combustible surfaces.
Do not install unit near flammables.
Do not overload building wiring − be sure power supply system is
properly sized, rated, and protected to handle this unit.
READ INSTRUCTIONS.
Read and follow all labels and the Owner’s
Manual carefully before installing, operating, or
servicing unit. Read the safety information at
the beginning of the manual and in each
section.
Use only genuine replacement parts from the manufacturer.
Perform maintenance and service according to the Owner’s
Manuals, industry standards, and national, state, and local
codes.
1-3. Arc Welding And Plasma Cutting Hazards
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shocks
or severe burns. The electrode and work circuit is
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also
live when power is on. In semiautomatic or automatic
wire welding, the wire, wire reel, drive roll housing,
and all metal parts touching the welding wire are
electrically live. Incorrectly installed or improperly
grounded equipment is a hazard.
Do not touch live electrical parts.
Wear dry, hole-free insulating gloves and body protection.
Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.
Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
Use AC output ONLY if required for the welding or cutting process.
If AC output is required, use remote output control if present on
unit.
Additional safety precautions are required when any of the following electrically hazardous conditions are present: in damp
locations or while wearing wet clothing; on metal structures such
as floors, gratings, or scaffolds; when in cramped positions such
as sitting, kneeling, or lying; or when there is a high risk of unavoidable or accidental contact with the workpiece or ground. For these
conditions, use the following equipment in order presented: 1) a
semiautomatic DC constant voltage (wire) welder, 2) a DC manual
(stick) welder, or 3) an AC welder with reduced open-circuit voltage. In most situations, use of a DC, constant voltage wire welder
is recommended. And, do not work alone!
Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
Properly install, ground, and operate this equipment according to
its Owner’s Manual and national, state, and local codes.
Always verify the supply ground − check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
grounded receptacle outlet.
When making input connections, attach proper grounding conductor first − double-check connections.
Keep cords dry, free of oil and grease, and protected from hot metal
and sparks.
OM-260 545 Page 2
Frequently inspect input power cord for damage or bare wiring −
replace cord immediately if damaged − bare wiring can kill.
Turn off all equipment when not in use.
Do not use worn, damaged, undersized, or poorly spliced cables.
Do not drape cables over your body.
If earth grounding of the workpiece is required, ground it directly
with a separate cable.
Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
Do not touch electrode holders connected to two welding machines at the same time since double open-circuit voltage will be
present.
Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
Wear a safety harness if working above floor level.
Keep all panels and covers securely in place.
Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
Do not connect more than one electrode or work cable to any
single weld output terminal. Disconnect cable for process not in
use.
SIGNIFICANT DC VOLTAGE exists in inverter power sources AFTER removal of input power.
Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section
before touching any parts.
HOT PARTS can burn.
Do not touch hot parts bare handed.
Allow cooling period before working on equipment.
To handle hot parts, use proper tools and/or
wear heavy, insulated welding gloves and
clothing to prevent burns.
FUMES AND GASES can be hazardous.
Do not weld or cut where the atmosphere may contain flammable
dust, gas, or liquid vapors (such as gasoline).
Welding and cutting produces fumes and gases.
Breathing these fumes and gases can be hazardous
to your health.
Connect work cable to the work as close to the welding or cutting
area as practical to prevent welding or cutting current from traveling long, possibly unknown paths and causing electric shock,
sparks, and fire hazards.
Keep your head out of the fumes. Do not breathe the fumes.
Do not use welder to thaw frozen pipes.
If inside, ventilate the area and/or use local forced ventilation at the
arc to remove welding and cutting fumes and gases. The recommended way to determine adequate ventilation is to sample for the
composition and quantity of fumes and gases to which personnel
are exposed.
Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
If ventilation is poor, wear an approved air-supplied respirator.
Wear body protection made from durable, flame−resistant material
(leather, heavy cotton, wool). Body protection includes oil-free
clothing such as leather gloves, heavy shirt, cuffless trousers, high
shoes, and a cap.
Read and understand the Safety Data Sheets (SDSs) and the
manufacturer’s instructions for adhesives, coatings, cleaners,
consumables, coolants, degreasers, fluxes, and metals.
Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding or cutting.
Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watchperson nearby. Welding and cutting fumes and gases can displace
air and lower the oxygen level causing injury or death. Be sure the
breathing air is safe.
Use only correct fuses or circuit breakers. Do not oversize or bypass them.
Do not weld or cut in locations near degreasing, cleaning, or spraying operations. The heat and rays of the arc can react with vapors
to form highly toxic and irritating gases.
Do not weld or cut on coated metals, such as galvanized, lead, or
cadmium plated steel, unless the coating is removed from the weld
area, the area is well ventilated, and while wearing an air-supplied
respirator. The coatings and any metals containing these elements
can give off toxic fumes if welded.
ARC RAYS can burn eyes and skin.
Arc rays from welding and cutting processes
produce intense visible and invisible (ultraviolet and
infrared) rays that can burn eyes and skin. Sparks fly
off from the weld.
Wear an approved welding helmet fitted with a proper shade of
filter lenses to protect your face and eyes from arc rays and
sparks when welding, cutting, or watching (see ANSI Z49.1 and
Z87.1 listed in Safety Standards).
Wear approved safety glasses with side shields under your
helmet.
Use protective screens or barriers to protect others from flash,
glare and sparks; warn others not to watch the arc.
Wear body protection made from durable, flame−resistant material (leather, heavy cotton, wool). Body protection includes
oil-free clothing such as leather gloves, heavy shirt, cuffless
trousers, high shoes, and a cap.
WELDING AND CUTTING can cause
fire or explosion.
Welding or cutting on closed containers, such as
tanks, drums, or pipes, can cause them to blow up.
Sparks can fly off from the welding or cutting arc. The
flying sparks, hot workpiece, and hot equipment can
cause fires and burns. Accidental contact of electrode to metal
objects can cause sparks, explosion, overheating, or fire. Check and
be sure the area is safe before doing any welding or cutting.
Remove all flammables within 35 ft (10.7 m) of the welding or cutting arc. If this is not possible, tightly cover them with approved
covers.
Do not weld or cut where flying sparks can strike flammable
material.
Protect yourself and others from flying sparks and hot metal.
Be alert that welding sparks and hot materials from welding and
cutting can easily go through small cracks and openings to adjacent areas.
Watch for fire, and keep a fire extinguisher nearby.
Be aware that welding or cutting on a ceiling, floor, bulkhead, or
partition can cause fire on the hidden side.
Do not weld or cut on containers that have held combustibles, or on
closed containers such as tanks, drums, or pipes unless they are
properly prepared according to AWS F4.1 and AWS A6.0 (see
Safety Standards).
After completion of work, inspect area to ensure it is free of sparks,
glowing embers, and flames.
Follow requirements in OSHA 1910.252 (a) (2) (iv) and NFPA 51B
for hot work and have a fire watcher and extinguisher nearby.
Read and understand the Safety Data Sheets (SDSs) and the
manufacturer’s instructions for adhesives, coatings, cleaners,
consumables, coolants, degreasers, fluxes, and metals.
FLYING METAL or DIRT can injure eyes.
Welding, cutting, chipping, wire brushing, and
grinding cause sparks and flying metal. As
welds cool, they can throw off slag.
Wear approved safety glasses with side
shields even under your welding helmet.
BUILDUP OF GAS can injure or kill.
Shut off compressed gas supply when not in use.
Always ventilate confined spaces or use
approved air-supplied respirator.
CYLINDERS can explode if damaged.
Compressed gas cylinders contain gas under high
pressure. If damaged, a cylinder can explode. Since
gas cylinders are normally part of the welding
process, be sure to treat them carefully.
Protect compressed gas cylinders from excessive heat, mechanical shocks, physical damage, slag, open flames, sparks, and arcs.
Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
Keep cylinders away from any welding, cutting, or other electrical
circuits.
Never drape a welding or cutting torch over a gas cylinder.
Never allow a welding electrode or cutting torch to touch any
cylinder.
Never weld on a pressurized cylinder − explosion will result.
Use only correct compressed gas cylinders, regulators, hoses,
and fittings designed for the specific application; maintain them
and associated parts in good condition.
Turn face away from valve outlet when opening cylinder valve. Do
not stand in front of or behind the regulator when opening the valve.
Keep protective cap in place over valve except when cylinder is in
use or connected for use.
Use the right equipment, correct procedures, and sufficient number of persons to lift and move cylinders.
Read and follow instructions on compressed gas cylinders,
associated equipment, and Compressed Gas Association (CGA)
publication P-1 listed in Safety Standards.
OM-260 545 Page 3
ELECTRIC AND MAGNETIC FIELDS (EMF)
can affect Implanted Medical Devices.
Wearers of Pacemakers and other Implanted
Medical Devices should keep away.
Implanted Medical Device wearers should consult their doctor
and the device manufacturer before going near arc welding, spot
welding, gouging, plasma arc cutting, or induction heating
operations.
NOISE can damage hearing.
Noise from some processes or equipment can
damage hearing.
Wear approved ear protection if noise level is
high.
1-4. Additional Symbols For Installation, Operation, And Maintenance
FIRE OR EXPLOSION hazard.
Do not install or place unit on, over, or near
combustible surfaces.
Do not install unit near flammables.
Do not overload building wiring − be sure power supply system is
properly sized, rated, and protected to handle this unit.
BATTERY EXPLOSION can injure.
Do not use welder to charge batteries or jump
start vehicles unless the unit has a battery
charging feature designed for this purpose.
MOVING PARTS can injure.
FALLING EQUIPMENT can injure.
Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
Use equipment of adequate capacity to lift and
support unit.
If using lift forks to move unit, be sure forks are long enough to
extend beyond opposite side of unit.
Keep equipment (cables and cords) away from moving vehicles
when working from an aerial location.
Follow the guidelines in the Applications Manual for the Revised
NIOSH Lifting Equation (Publication No. 94−110) when manually lifting heavy parts or equipment.
OVERUSE can cause OVERHEATING
Allow cooling period; follow rated duty cycle.
Reduce current or reduce duty cycle before
starting to weld again.
Do not block or filter airflow to unit.
FLYING SPARKS can injure.
Wear a face shield to protect eyes and face.
Shape tungsten electrode only on grinder with
proper guards in a safe location wearing proper
face, hand, and body protection.
Sparks can cause fires — keep flammables away.
STATIC (ESD) can damage PC boards.
Put on grounded wrist strap BEFORE handling
boards or parts.
Use proper static-proof bags and boxes to
store, move, or ship PC boards.
MOVING PARTS can injure.
Keep away from moving parts.
Keep away from pinch points such as drive
rolls.
WELDING WIRE can injure.
Do not press gun trigger until instructed to do
so.
Do not point gun toward any part of the body,
other people, or any metal when threading
welding wire.
OM-260 545 Page 4
Keep away from moving parts such as fans.
Keep all doors, panels, covers, and guards
closed and securely in place.
Have only qualified persons remove doors, panels, covers, or
guards for maintenance and troubleshooting as necessary.
Reinstall doors, panels, covers, or guards when maintenance is
finished and before reconnecting input power.
COMPRESSED AIR can injure or kill.
Before working on compressed air system,
turn off and lockout/tagout unit, release pressure, and be sure air pressure cannot be accidentally applied.
Relieve pressure before disconnecting or connecting air lines.
Check compressed air system components
and all connections and hoses for damage,
leaks, and wear before operating unit.
Do not direct air stream toward self or others.
Wear protective equipment such as safety glasses, hearing protection, leather gloves, heavy shirt and trousers, high shoes, and
a cap when working on compressed air system.
Use soapy water or an ultrasonic detector to search for
leaks−−never use bare hands. Do not use equipment if leaks are
found.
Reinstall doors, panels, covers, or guards when servicing is
finished and before starting unit.
If ANY air is injected into the skin or body seek medical help immediately.
BREATHING COMPRESSED AIR can injure or kill.
Do not use compressed air for breathing.
Use only for cutting, gouging, and tools.
TRAPPED AIR PRESSURE AND WHIPPING
HOSES can injure.
Release air pressure from tools and system before servicing, adding or changing attachments, or opening compressor oil drain or oil fill
cap.
READ INSTRUCTIONS.
Read and follow all labels and the Owner’s
Manual carefully before installing, operating, or
servicing unit. Read the safety information at
the beginning of the manual and in each
section.
Use only genuine replacement parts from the manufacturer.
Perform maintenance and service according to the Owner’s
Manuals, industry standards, and national, state, and local
codes.
H.F. RADIATION can cause interference.
High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communications equipment.
Have only qualified persons familiar with
electronic equipment perform this installation.
The user is responsible for having a qualified electrician promptly
correct any interference problem resulting from the installation.
If notified by the FCC about interference, stop using the equipment
at once.
Have the installation regularly checked and maintained.
Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.
ARC WELDING AND PLASMA CUTTING can
cause interference.
Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.
Be sure all equipment in the welding area is electromagnetically
compatible.
To reduce possible interference, keep cables as short as
possible, close together, and down low, such as on the floor.
Locate welding or cutting operation 100 meters from any sensitive electronic equipment.
Be sure welding machine or plasma cutter is installed and
grounded according to this manual.
If interference still occurs, the user must take extra measures
such as moving the welding or cutting machine, using shielded
cables, using line filters, or shielding the work area.
1-5. California Proposition 65 Warnings
Welding or cutting equipment produces fumes or gases
which contain chemicals known to the State of California to
cause birth defects and, in some cases, cancer. (California
Health & Safety Code Section 25249.5 et seq.)
This product contains chemicals, including lead, known to
the state of California to cause cancer, birth defects, or other
reproductive harm. Wash hands after use.
1-6. Principal Safety Standards
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
is available as a free download from the American Welding Society at
http://www.aws.org or purchased from Global Engineering Documents
(phone: 1-877-413-5184, website: www.global.ihs.com).
Safe Practices for the Preparation of Containers and Piping for Welding
and Cutting, American Welding Society Standard AWS F4.1, from Global Engineering Documents (phone: 1-877-413-5184, website:
www.global.ihs.com).
Safe Practices for Welding and Cutting Containers that have Held Combustibles, American Welding Society Standard AWS A6.0, from Global
Engineering Documents (phone: 1-877-413-5184,
website: www.global.ihs.com).
National Electrical Code, NFPA Standard 70, from National Fire Protection Association, Quincy, MA 02269 (phone: 1-800-344-3555, website:
www.nfpa.org and www. sparky.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 14501 George Carter Way, Suite
103, Chantilly, VA 20151 (phone: 703-788-2700, website:www.cganet.com).
Safety in Welding, Cutting, and Allied Processes, CSA Standard
W117.2, from Canadian Standards Association, Standards Sales, 5060
Spectrum Way, Suite 100, Ontario, Canada L4W 5NS (phone:
800-463-6727, website: www.csa-international.org).
Safe Practice For Occupational And Educational Eye And Face Protection, ANSI Standard Z87.1, from American National Standards Institute,
25 West 43rd Street, New York, NY 10036 (phone: 212-642-4900, website: www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, from National Fire Protection Association,
Quincy, MA 02269 (phone: 1-800-344-3555, website: www.nfpa.org.
OSHA, Occupational Safety and Health Standards for General Industry, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,
and Part 1926, Subpart J, from U.S. Government Printing Office, Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954
(phone: 1-866-512-1800) (there are 10 OSHA Regional Offices—
phone for Region 5, Chicago, is 312-353-2220, website:
www.osha.gov).
Applications Manual for the Revised NIOSH Lifting Equation, The National Institute for Occupational Safety and Health (NIOSH), 1600
Clifton Rd, Atlanta, GA 30333 (phone: 1-800-232-4636, website:
www.cdc.gov/NIOSH).
1-7. EMF Information
Electric current flowing through any conductor causes localized electric
and magnetic fields (EMF).The current from arc welding (and allied processes including spot welding, gouging, plasma arc cutting, and
induction heating operations) creates an EMF field around the welding
circuit. EMF fields may interfere with some medical implants, e.g. pacemakers. Protective measures for persons wearing medical implants
have to be taken. For example, restrict access for passers−by or conduct individual risk assessment for welders. All welders should use the
following procedures in order to minimize exposure to EMF fields from
the welding circuit:
a. Keep cables close together by twisting or taping them, or using a
cable cover.
b. Do not place your body between welding cables. Arrange cables
to one side and away from the operator.
c. Do not coil or drape cables around your body.
d. Keep head and trunk as far away from the equipment in the
welding circuit as possible.
e. Connect work clamp to workpiece as close to the weld as
possible.
f. Do not work next to, sit or lean on the welding power source.
g. Do not weld whilst carrying the welding power source or wire
feeder.
About Implanted Medical Devices:
Implanted Medical Device wearers should consult their doctor and the
device manufacturer before performing or going near arc welding, spot
welding, gouging, plasma arc cutting, or induction heating operations.
If cleared by your doctor, then following the above procedures is recommended.
OM-260 545 Page 5
SECTION 2 − MESURES DE SÉCURITÉ −
EXTRACTION DES FUMÉES − À LIRE AVANT UTILISATION
fume_2014−04_fre
Se protéger et protéger les autres contre le risque de blessure — lisez, appliquez et rangez en lieu sûr ces consignes importantes de
sécurité et d’utilisation.
2-1. Symboles utilisés
DANGER! − Indique une situation dangereuse qui si on
l’évite pas peut donner la mort ou des blessures graves.
Les dangers possibles sont montrés par les symboles
joints ou sont expliqués dans le texte.
Indique une situation dangereuse qui si on l’évite pas
peut donner la mort ou des blessures graves. Les dangers possibles sont montrés par les symboles joints ou
sont expliqués dans le texte.
NOTE − Indique des déclarations pas en relation avec des blessures
personnelles.
Indique des instructions spécifiques.
Ce groupe de symboles veut dire Avertissement! Attention! DANGER
DE CHOC ELECTRIQUE, PIECES EN MOUVEMENT, et PIECES
CHAUDES. Consulter les symboles et les instructions ci-dessous y
afférant pour les actions nécessaires afin d’éviter le danger.
2-2. Dangers en matière d’extraction des fumées
Les symboles représentés ci-dessous sont utilisés dans ce manuel pour attirer l’attention et identifier les dangers possibles. En
présence de l’un de ces symboles, prendre garde et suivre les
instructions afférentes pour éviter tout risque. Les instructions
en matière de sécurité indiquées ci-dessous ne constituent
qu’un sommaire des instructions de sécurité plus complètes
fournies dans les normes de sécurité énumérées dans la Section
2-6.. Lire et observer toutes les normes de sécurité.
Seul un personnel qualifié est autorisé à installer, faire fonctionner, entretenir et réparer cet appareil.
Pendant le fonctionnement, maintenir à distance toutes les
personnes, notamment les enfants de l’appareil.
LA MAUVAISE UTILISATION DES EXTRACTEURS DE FUMÉES peut comporter des
dangers.
Le soudage produit des vapeurs et des fumées qu’il
est dangereux de respirer. Les matériaux
combustibles peuvent s’enflammer et causer un incendie ou une explosion.
Lire et observer minutieusement les présentes instructions et les
étiquettes de sécurité. L’extracteur de fumées aide à protéger
l’utilisateur contre les aérocontaminants, mais on doit l’utiliser
correctement pour bénéficier de son efficacité. Confiez la
vérification de la qualité de l’air dans votre établissement à un
hygiéniste industriel pour confirmer que l’extracteur de fumées
procure une protection adéquate contre les aérocontaminants
présents dans le milieu de travail. Si vous avez des questions au
sujet de l’extracteur, consultez l’étiquette apposée sur l’appareil,
votre directeur de la sécurité ou un hygiéniste industriel certifié.
Suivre toutes les directives ANSI, OSHA, CSA, UL et autres
portant sur l’utilisation des extracteurs de fumées et la recirculation
de l’air filtré.
Certaines sections de l’équipement de captage de fumées,
notamment les chambres d’air propre et sale, peuvent être
considérées des espaces confinés aux termes d’OSHA. Consulter
le règlement OSHA pertinent afin de déterminer si l’installation est
un espace confiné qui nécessite l’obtention d’un permis.
Ne pas utiliser un extracteur de fumées sans pare−étincelles
approuvé et correctement installé, à moins que l’appareil soit
conçu pour fonctionner sans pare−étincelles. Sans le pare−
étincelles, les étincelles de soudage peuvent enflammer un filtre
non ignifuge ou des vapeurs déposées sur le filtre,
ou endommager celui−ci et générer la pénétration d’air non filtré
dans la zone de respiration. Ne pas laisser des étincelles ou des
matériaux qui se consument pénétrer dans le capot ou le conduit
de l’extracteur de fumées.
Utiliser l’extracteur de fumées uniquement pour extraire les
fumées de soudage. Ne pas l’employer pour extraire des gaz
OM-260 545 Page 6
chauds (à plus de 140° F/60° C), des poussières de bois ou de
ciment, des gaz d’échappement de moteur, des vapeurs de
liquides, des matières explosives, des émanations agressives
(acides), de la fumée produite par des objets qui se consument ou
encore des fumées provenant d’opérations de nettoyage, de
découpage, de gougeage, de meulage, de peinture, de projection à
la flamme, de sablage ou d’activités autres que le soudage. Ne pas
installer ou utiliser un extracteur de fumées aux endroits ou des
matériaux combustibles peuvent être présents.
Les vapeurs générées par des opérations de soudage peuvent
être inflammables. Ne pas installer ou utiliser un extracteur
de vapeurs en présence possible de vapeurs de soudage
inflammables sauf si un système de protection contre l’incendie
et/ou l’explosion est prévu et a été choisi et approuvé par une
personne qualifiée bien informée des codes et des systèmes
contre l’incendie et/ou l’explosion applicables.
Utiliser l’extracteur de fumées seulement dans des atmosphères
pour lesquelles il est recommandé. Ne pas utiliser l’extracteur dans
des endroits où la concentration de contaminants est inconnue,
représente un danger immédiat pour la vie ou dépasse la capacité
nominale de l’extracteur.
Ne pas souder sans être sûr que l’extracteur de fumées est bien
assemblé et qu’il fonctionne correctement.
Avant chaque utilisation, inspecter l’extracteur et vérifier qu’il
fonctionne correctement.
Les contaminants dangereux peuvent être inodores et incolores.
Quitter immédiatement l’aire de travail en présence des situations
suivantes:
h La respiration devient difficile.
i Apparition d’étourdissements, de problèmes de vision ou irritation des yeux, du nez ou de la bouche.
j L’équipement est endommagé.
k La circulation d’air subit une baisse ou s’arrête.
l Si vous croyez que l’équipement ne procure pas une protection
adéquate.
Ne pas réparer, modifier ou démonter l’extracteur de fumées ou
l’utiliser avec des pièces ou accessoires non fournis par le
fabricant. Utiliser uniquement des composants approuvés par le
fabricant.
Remplacer tout filtre endommagé ou bouché. Laisser refroidir
avant d’inspecter ou de remplacer le filtre, ou nettoyer le tiroir de
poussière et le par-étincelle. Ne pas le laver, le réutiliser ou le
nettoyer en le secouant ou avec de l’air comprimé, à moins que le
fabricant le recommande expressément dans le mode d’emploi
(l’élément filtrant pourrait s’endommager). Ne pas respirer ces
particules de poussière. Éliminer tout élément de filtres usés et les
particules recueillies selon les réglementations locales, nationales
et fédérales.Porter du matériel de sécurité approuvé (appareil
respiratoire, gants, chemise à manches longues) pour faire
l’entretien du filtre. Éliminer tout élément de filtres usés et les
particules recueillies selon les réglementations locales, nationales
et fédérales.
Lire et comprendre les fiches de données de sécurité et les
instructions du fabricant concernant les adhésifs, les revêtements, les
nettoyants, les consommables, les produits de refroidissement, les
dégraisseurs, les flux et les métaux.
L’extracteur de fumées doit être utilisé avec le bras d’extraction, les
tuyaux, le filtre et les autres composants recommandés par le
fabricant.
UNE DÉCHARGE ÉLECTRIQUE peut
entraîner la mort.
Le contact d’organes électriques sous tension peut
provoquer des accidents mortels ou des brûlures
graves. Le circuit d’alimentation et les circuits
internes de la machine sont également sous tension
lorsque l’alimentation est sur Marche. Un équipement installé ou mis
à la terre de manière incorrecte ou impropre constitue un danger.
Ne pas toucher aux pièces électriques sous tension.
Couper l’alimentation ou arrêter le moteur avant de procéder à l’installation, à la réparation ou à l’entretien de l’appareil. Déverrouiller
l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de sécurité).
Installer le poste correctement et le mettre à la terre convenablement selon les consignes du manuel de l’opérateur et les normes
nationales, provinciales et locales.
Toujours vérifier la terre du cordon d’alimentation. Vérifier et
s’assurer que le fil de terre du cordon d’alimentation est bien
raccordé à la borne de terre du sectionneur ou que la fiche du
cordon est raccordée à une prise correctement mise à la terre.
Vérifier fréquemment le cordon d’alimentation et le conducteur de
mise à la terre afin de s’assurer qu’il n’est pas altéré ou dénudé −, le
remplacer immédiatement s’il l’est −. Un fil dénudé peut entraîner la
mort.
LA CHUTE DE L’ÉQUIPEMENT peut
provoquer des blessures.
Utiliser un équipement de levage de capacité
suffisante pour lever l’appareil.
En utilisant des fourches de levage pour déplacer l’unité, s’assurer que les fourches sont
suffisamment longues pour dépasser du côté
opposé de l’appareil.
Tenir l’équipement (câbles et cordons) à distance des véhicules
mobiles lors de toute opération en hauteur.
Suivre les consignes du Manuel des applications pour l’équation
de levage NIOSH révisée (Publication Nº94–110) lors du levage
manuelle de pièces ou équipements lourds.
Les PIÈCES MOBILES peuvent
causer des blessures.
S’abstenir de toucher des organes mobiles tels
que des ventilateurs.
Maintenir fermés et verrouillés les portes,
panneaux, recouvrements et dispositifs de
protection.
Lorsque cela est nécessaire pour des travaux d’entretien et de
dépannage, faire retirer les portes, panneaux, recouvrements
ou dispositifs de protection uniquement par du personnel qualifié.
Remettre les portes, panneaux, recouvrements ou dispositifs de
protection quand l’entretien est terminé et avant de rebrancher
l’alimentation électrique.
Risque D’INCENDIE OU
D’EXPLOSION.
Ne pas placer l’appareil sur, au-dessus ou
à proximité de surfaces inflammables.
Ne pas installer l’appareil à proximité de produits inflammables.
Ne pas surcharger l’installation électrique − s’assurer que
l’alimentation est correctement dimensionnée et protégée avant
de mettre l’appareil en service.
LIRE LES INSTRUCTIONS.
Lire et appliquer les instructions sur les
étiquettes et le Mode d’emploi avant l’installation, l’utilisation ou l’entretien de l’appareil.
Lire les informations de sécurité au début du
manuel et dans chaque section.
N’utiliser que les pièces de rechange recommandées par le
constructeur.
2-3. Dangers du soudage à l’arc et du coupage au plasma
UNE DÉCHARGE ÉLECTRIQUE peut
entraîner la mort.
Le contact d’organes électriques sous tension peut
provoquer des accidents mortels ou des brûlures
graves. Le circuit de l’électrode et de la pièce est
sous tension lorsque le courant est délivré à la
sortie. Le circuit d’alimentation et les circuits internes de la machine sont également sous tension
lorsque l’alimentation est sur Marche. Dans le mode
de soudage avec du fil, le fil, le dérouleur, le bloc de
commande du rouleau et toutes les parties métalliques en contact avec le fil sont sous tension
électrique. Un équipement installé ou mis à la terre
de manière incorrecte ou impropre constitue un
danger.
Ne pas toucher aux pièces électriques sous tension.
Porter des gants isolants et des vêtements de protection secs et
sans trous.
S’isoler de la pièce à couper et du sol en utilisant des housses ou
des tapis assez grands afin d’éviter tout contact physique avec la
pièce à couper ou le sol.
Ne pas se servir de source électrique à courant électrique dans les
zones humides, dans les endroits confinés ou là où on risque de
tomber.
Utilisez une source de soudage AC UNIQUEMENT si le procédé
de soudage et de coupage le demande.
Si l’utilisation d’une source électrique à courant électrique s’avère
nécessaire, se servir de la fonction de télécommande si l’appareil
en est équipé.
D’autres consignes de sécurité sont nécessaires dans les conditions suivantes : risques électriques dans un environnement
humide ou si l’on porte des vêtements mouillés ; sur des structures
métalliques telles que sols, grilles ou échafaudages ; en position
coincée comme assise, à genoux ou couchée ; ou s’il y a un risque
élevé de contact inévitable ou accidentel avec la pièce à souder ou
le sol. Dans ces conditions, utiliser les équipements suivants, dans
l’ordre indiqué : 1) un poste à souder DC à tension constante (à fil),
2) un poste à souder DC manuel (électrode) ou 3) un poste à souder AC à tension à vide réduite. Dans la plupart des situations,
l’utilisation d’un poste à souder DC à fil à tension constante est recommandée. En outre, ne pas travailler seul !
Couper l’alimentation ou arrêter le moteur avant de procéder à l’installation, à la réparation ou à l’entretien de l’appareil. Déverrouiller
l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de sécurité).
Installer le poste correctement et le mettre à la terre convenablement selon les consignes du manuel de l’opérateur et les normes
nationales, provinciales et locales.
Toujours vérifier la terre du cordon d’alimentation. Vérifier et
s’assurer que le fil de terre du cordon d’alimentation est bien
raccordé à la borne de terre du sectionneur ou que la fiche du
cordon est raccordée à une prise correctement mise à la terre.
OM-260 545 Page 7
En effectuant les raccordements d’entrée, fixer d’abord le conducteur de mise à la terre approprié et contre-vérifier les connexions.
Les câbles doivent être exempts d’humidité, d’huile et de graisse;
protégez−les contre les étincelles et les pièces métalliques
chaudes.
Vérifier fréquemment le cordon d’alimentation afin de s’assurer
qu’il n’est pas altéré ou à nu, le remplacer immédiatement s’il l’est.
Un fil à nu peut entraîner la mort.
L’équipement doit être hors tension lorsqu’il n’est pas utilisé.
Ne pas utiliser des câbles usés, endommagés, de grosseur insuffisante ou mal épissés.
Ne pas enrouler les câbles autour du corps.
Si la pièce soudée doit être mise à la terre, le faire directement avec
un câble distinct.
Ne pas toucher l’électrode quand on est en contact avec la pièce, la
terre ou une électrode provenant d’une autre machine.
Ne pas toucher des porte électrodes connectés à deux machines en
même temps à cause de la présence d’une tension à vide doublée.
N’utiliser qu’un matériel en bon état. Réparer ou remplacer sur-lechamp les pièces endommagées. Entretenir l’appareil conformément à ce manuel.
Porter un harnais de sécurité si l’on doit travailler au-dessus du sol.
S’assurer que tous les panneaux et couvercles sont correctement
en place.
Fixer le câble de retour de façon à obtenir un bon contact métal-métal avec la pièce à souder ou la table de travail, le plus près possible
de la soudure.
Isoler la pince de masse quand pas mis à la pièce pour éviter le
contact avec tout objet métallique.
Ne pas raccorder plus d’une électrode ou plus d’un câble de masse
à une même borne de sortie de soudage. Débranchez le câble
pour procédé non utilisé.
Il reste une TENSION DC NON NÉGLIGEABLE dans
les sources de soudage onduleur UNE FOIS
l’alimentation coupée.
Arrêter les convertisseurs, débrancher le courant électrique et
décharger les condensateurs d’alimentation selon les instructions
indiquées dans la partie Entretien avant de toucher les pièces.
LES PIÈCES CHAUDES peuvent
provoquer des brûlures.
Ne pas toucher à mains nues les parties
chaudes.
Prévoir une période de refroidissement avant de
travailler à l’équipement.
Ne pas toucher aux pièces chaudes, utiliser les
outils recommandés et porter des gants de soudage et des vêtements épais pour éviter les brûlures.
LES FUMÉES ET LES GAZ peuvent
être dangereux.
Le soudage et le coupage produisent des vapeurs
et des gaz. Leur inhalation peut être dangereuse
pour votre santé.
Eloigner votre tête des fumées. Ne pas respirer les fumées.
A l’intérieur, ventilez la pièce ou ayez recours à une ventilation
aspirante installée près de l’arc pour évacuer les vapeurs
et les gaz. Pour déterminer la bonne ventilation, il est recommandé
de procéder à un prélèvement pour la composition et la quantité de
fumées et de gaz auxquels est exposé le personnel.
Si la ventilation est médiocre, porter un respirateur anti-vapeurs
approuvé.
Lire et comprendre les fiches de données de sécurité et les instructions du fabricant concernant les adhésifs, les revêtements, les
nettoyants, les consommables, les produits de refroidissement, les
dégraisseurs, les flux et les métaux.
Travailler dans un espace fermé seulement s’il est bien ventilé
ou en portant un respirateur à alimentation d’air. Prévoyez toujours
un surveillant formé à proximité. Les vapeurs de soudage et de
coupage peuvent déplacer de l’air et abaisser le niveau d’oxygène,
cause de lésion ou de mort. Assurez−vous de la qualité de l’air que
vous respirez.
Ne soudez pas ou ne coupez pas près de zones où sont effectuées
des opérations de dégraissage, nettoyage ou pulvérisation. La
OM-260 545 Page 8
chaleur et les rayons de l’arc peuvent réagir en présence de vapeurs et former des gaz hautement toxiques et irritants.
Ne soudez pas ou ne coupez pas des métaux enrobés tels que des
métaux galvanisés, contenant du plomb ou de l’acier plaqué au
cadmium, à moins que l’enrobage ne soit ôté de la surface
de soudage, que l’endroit où vous travaillez ne soit bien ventilé, ou,
si nécessaire, que vous ne portiez un respirateur alimenté en air.
Les enrobages ou tous métaux contenant ces éléments peuvent
créer des vapeurs toxiques s’ils sont soudés ou coupés.
LES RAYONS DE L’ARC peuvent
provoquer des brûlures dans les
yeux et sur la peau.
Les rayons d’arc issus des procédés de soudage et de
coupage produisent des rayons visibles et invisibles
intenses (ultraviolets et infrarouges) qui peuvent
entraîner des brûlures aux yeux et à la peau.
Des étincelles jaillissent de la soudure.
Portez un casque de soudage approuvé muni de verres filtrants
appropriés pour protéger visage et yeux contre les rayons et les
étincelles d’arc pendant le soudage, le coupage ou la surveillance
(voir ANSI Z49.1 et Z87.1 énuméré dans les Normes de Sécurité).
Porter des lunettes de sécurité avec écrans latéraux même sous
votre casque.
Avoir recours à des écrans protecteurs ou à des rideaux pour
protéger les autres contre les rayonnements les éblouissements et
les étincelles ; prévenir toute personne sur les lieux de ne pas
regarder l’arc.
Porter un équipement de protection pour le corps fait d’un matériau
résistant et ignifuge (cuir, coton robuste, laine). La protection du
corps comporte des vêtements sans huile comme par ex. des
gants de cuir, une chemise solide, des pantalons sans revers, des
chaussures hautes et une casquette.
Le SOUDAGE ET le COUPAGE
présentent un risque d’incendie
ou d’explosion.
Le soudage ou le coupage effectué sur des conteneurs fermés, tels que réservoirs, tambours ou
conduites, peut causer leur explosion. Des étincelles
peuvent être projetées de l’arc de soudure. La projection d’étincelles,
des pièces chaudes et des équipements chauds peut provoquer des
incendies et des brûlures. Le contact accidentel de l’électrode avec
des objets métalliques peut provoquer des étincelles, une explosion,
un surchauffement ou un incendie. Avant de commencer le soudage,
vérifier et s’assurer que l’endroit ne présente pas de danger.
Ecartez tout produit inflammable situé à moins de 35 pieds
(10,7 m) de l’arc de soudage ou de coupage. En cas d’impossibilité
les recouvrir soigneusement avec des protections homologués.
Ne soudez pas ou ne coupez pas dans un endroit où des étincelles
pourraient atteindre des matières inflammables.
Se protéger et d’autres personnes de la projection d’étincelles et
de métal chaud.
Assurez−vous qu’aucune étincelle ni matière chaude provenant
du soudage ou du coupage ne peut se glisser dans de petites
fissures ou tomber dans d’autres pièces contiguës.
Surveiller tout déclenchement d’incendie et tenir un extincteur à
proximité.
Si vous soudez ou coupez sur un plafond, un plancher ou
une cloison, soyez conscient que cela peut entraîner un incendie
de l’autre côté.
N’effectuez pas de soudage ou de coupage sur des conteneurs ayant stocké des combustibles ou sur des conteneurs fermés
tels que des réservoirs, tambours, ou conduites, à moins qu’ils
n’aient été préparés correctement conformément à AWS F4.1
et AWS A6.0 (voir les Normes de Sécurité).
Ne soudez pas ou ne coupez pas si l’air ambiant est chargé
de particules, gaz, ou vapeurs inflammables (vapeur d’essence,
par exemple).
Fixez le câble de masse sur la pièce à couper, le plus près possible
de la zone à souder ou à couper afin d’éviter que le courant de
soudage ou de coupage ne prenne une trajectoire inconnue ou
longue et ne cause ainsi une décharge électrique ou un incendie.
Ne pas utiliser le poste de soudage pour dégeler des conduites gelées.
En cas de non utilisation, enlever la baguette d’électrode du porteélectrode ou couper le fil à la pointe de contact.
Porter un équipement de protection pour le corps fait d’un matériau
résistant et ignifuge (cuir, coton robuste, laine). La protection du
corps comporte des vêtements sans huile comme par ex. des
gants de cuir, une chemise solide, des pantalons sans revers, des
chaussures hautes et une casquette.
Avant de souder, retirer toute substance combustible de vos poches telles qu’un allumeur au butane ou des allumettes.
Une fois le travail achevé, assurez−vous qu’il ne reste aucune
trace d’étincelles incandescentes ni de flammes.
Utiliser exclusivement des fusibles ou coupe−circuits appropriés.
Ne pas augmenter leur puissance; ne pas les ponter.
Suivre les recommandations dans OSHA 1910.252(a)(2)(iv) et
NFPA 51B pour les travaux à chaud et avoir de la surveillance et un
extincteur à proximité.
Lire et comprendre les fiches de données de sécurité et les
instructions du fabricant concernant les adhésifs, les revêtements, les
nettoyants, les consommables, les produits de refroidissement, les
dégraisseurs, les flux et les métaux.
DES PIECES DE METAL ou DES
SALETES peuvent provoquer des
blessures dans les yeux.
Le soudage, l’écaillement, le passage de la pièce à la brosse en fil de fer, et le meulage génèrent des étincelles et des particules métalliques
volantes.Pendant la période de refroidissement des soudures, elles risquent de
projeter du laitier.
Porter des lunettes de sécurité avec écrans latéraux ou un écran
facial.
Tourner le dos à la sortie de vanne lors de l’ouverture de la vanne
de la bouteille. Ne pas se tenir devant ou derrière le régulateur lors
de l’ouverture de la vanne.
Le couvercle du détendeur doit toujours être en place, sauf lorsque
la bouteille est utilisée ou qu’elle est reliée pour usage ultérieur.
Utiliser les équipements corrects, les bonnes procédures et suffisamment de personnes pour soulever et déplacer les bouteilles.
Lire et suivre les instructions sur les bouteilles de gaz comprimé,
l’équipement connexe et le dépliant P-1 de la CGA (Compressed
Gas Association) mentionné dans les principales normes de sécurité.
LE BRUIT peut endommager l’ouïe.
Le bruit des processus et des équipements peut
affecter l’ouïe.
Porter des protections approuvées pour les
oreilles si le niveau sonore est trop élevé.
LES BOUTEILLES peuvent exploser
si elles sont endommagées.
Les bouteilles de gaz comprimé contiennent du gaz
sous haute pression. Si une bouteille est
endommagée, elle peut exploser. Du fait que les
bouteilles de gaz font normalement partie du
procédé de soudage, les manipuler avec
précaution.
Protéger les bouteilles de gaz comprimé d’une chaleur excessive,
des chocs mécaniques, des dommages physiques, du laitier, des
flammes ouvertes, des étincelles et des arcs.
LES BOUTEILLES peuvent exploser
si elles sont endommagées.
Placer les bouteilles debout en les fixant dans un support stationnaire ou dans un porte-bouteilles pour les empêcher de tomber ou
de se renverser.
Les bouteilles de gaz comprimé contiennent du gaz
sous haute pression. Si une bouteille est
endommagée, elle peut exploser. Du fait que les
bouteilles de gaz font normalement partie du
procédé de soudage, les manipuler avec
précaution.
Les bouteilles ne doivent pas être près de la zone de soudage
ou de coupage ni de tout autre circuit électrique.
Protéger les bouteilles de gaz comprimé d’une chaleur excessive,
des chocs mécaniques, des dommages physiques, du laitier, des
flammes ouvertes, des étincelles et des arcs.
Placer les bouteilles debout en les fixant dans un support stationnaire ou dans un porte-bouteilles pour les empêcher de tomber ou
de se renverser.
Tenir les bouteilles éloignées des circuits de soudage ou autres circuits électriques.
Ne jamais placer une torche de soudage sur une bouteille à gaz.
Une électrode de soudage ne doit jamais entrer en contact avec
une bouteille.
Ne jamais souder une bouteille pressurisée − risque d’explosion.
Utiliser seulement des bouteilles de gaz comprimé, régulateurs,
tuyaux et raccords convenables pour cette application spécifique;
les maintenir ainsi que les éléments associés en bon état.
Ne placez jamais une torche de soudage ou de coupage
sur une bouteille de gaz.
Ne laissez jamais une électrode de soudage ou une torche de coupage en contact avec une bouteille.
Ne jamais souder une bouteille pressurisée − risque d’explosion.
Utiliser seulement des bouteilles de gaz comprimé, régulateurs,
tuyaux et raccords convenables pour cette application spécifique;
les maintenir ainsi que les éléments associés en bon état.
Détourner votre visage du détendeur-régulateur lorsque vous
ouvrez la soupape de la bouteille.
Le couvercle du détendeur doit toujours être en place, sauf lorsque
la bouteille est utilisée ou qu’elle est reliée pour usage ultérieur.
Utiliser les équipements corrects, les bonnes procédures et suffisamment de personnes pour soulever et déplacer les bouteilles.
Lire et suivre les instructions sur les bouteilles de gaz comprimé,
l’équipement connexe et le dépliant P-1 de la CGA (Compressed
Gas Association) mentionné dans les principales normes de sécurité.
2-4. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance
Risque D’INCENDIE OU
D’EXPLOSION.
Ne pas placer l’appareil sur, au-dessus ou
à proximité de surfaces inflammables.
Ne pas installer l’appareil à proximité de produits inflammables.
Ne pas surcharger l’installation électrique − s’assurer que
l’alimentation est correctement dimensionnée et protégée avant
de mettre l’appareil en service.
LA CHUTE DE L’ÉQUIPEMENT peut
provoquer des blessures.
Utiliser l’anneau de levage uniquement pour
soulever l’appareil, NON PAS les chariots, les
bouteilles de gaz ou tout autre accessoire.
Utiliser un équipement de levage de capacité
suffisante pour lever l’appareil.
En utilisant des fourches de levage pour déplacer l’unité, s’assurer que les fourches sont suffisamment longues pour dépasser
du côté opposé de l’appareil.
OM-260 545 Page 9
Tenir l’équipement (câbles et cordons) à distance des véhicules
mobiles lors de toute opération en hauteur.
Suivre les consignes du Manuel des applications pour l’équation
de levage NIOSH révisée (Publication Nº94–110) lors du levage
manuelle de pièces ou équipements lourds.
L’EMPLOI
EXCESSIF
peut
SURCHAUFFER L’ÉQUIPEMENT.
Prévoir une période de refroidissement ; respecter le cycle opératoire nominal.
Réduire le courant ou le facteur de marche
avant de poursuivre le soudage.
Ne pas obstruer les passages d’air du poste.
Les PIÈCES MOBILES peuvent
causer des blessures.
S’abstenir de toucher des organes mobiles tels
que des ventilateurs.
Maintenir fermés et verrouillés les portes,
panneaux, recouvrements et dispositifs de
protection.
Lorsque cela est nécessaire pour des travaux d’entretien et de
dépannage, faire retirer les portes, panneaux, recouvrements
ou dispositifs de protection uniquement par du personnel qualifié.
Remettre les portes, panneaux, recouvrements ou dispositifs de
protection quand l’entretien est terminé et avant de rebrancher
l’alimentation électrique.
LES ÉTINCELLES PROJETÉES
peuvent provoquer des blessures.
L’AIR COMPRIMÉ risque de provoquer
des blessures ou même la mort.
Porter un écran facial pour protéger le visage et
les yeux.
Affûter l’électrode au tungstène uniquement à la
meuleuse dotée de protecteurs. Cette
manœuvre est à exécuter dans un endroit sûr
lorsque l’on porte l’équipement homologué de
protection du visage, des mains et du corps.
Les étincelles risquent de causer un incendie − éloigner toute substance inflammable.
LES CHARGES ÉLECTROSTATIQUES peuvent endommager les circuits imprimés.
Établir la connexion avec la barrette de terre
avant de manipuler des cartes ou des pièces.
Utiliser des pochettes et des boîtes antistatiques pour stocker,
déplacer ou expédier des cartes de circuits imprimes.
Les PIÈCES MOBILES peuvent
causer des blessures.
Ne pas s’approcher des organes mobiles.
Ne pas s’approcher des points de coincement
tels que des rouleaux de commande.
LES FILS DE SOUDAGE peuvent
provoquer des blessures.
Ne pas appuyer sur la gâchette avant d’en
avoir reçu l’instruction.
Ne pas diriger le pistolet vers soi, d’autres
personnes ou toute pièce mécanique en
engageant le fil de soudage.
L’EXPLOSION DE LA BATTERIE peut
provoquer des blessures.
N’utilisez pas l’appareil de soudage pour
charger des batteries ou faire démarrer des
véhicules à l’aide de câbles de démarrage,
sauf si l’appareil dispose d’une fonctionnalité
de charge de batterie destinée à cet usage.
OM-260 545 Page 10
Avant d’intervenir sur le circuit d’air comprimé,
couper l’alimentation électrique, verrouiller
et étiqueter l’appareil, détendre la pression
et s’assurer que le circuit d’air ne peut être mis
sous pression par inadvertance.
Détendre la pression avant de débrancher ou
de brancher des canalisations d’air.
Avant
d’utiliser
l’appareil,
contrôler
les composants du circuit d’air comprimé,
les branchements et les flexibles en
recherchant tout signe de détérioration, de fuite
et d’usure.
Ne pas diriger un jet d’air vers soi−même ou vers autrui.
Pour intervenir sur un circuit d’air comprimé, porter un équipement
de protection tel que des lunettes de sécurité, des gants de cuir,
une chemise et un pantalon en tissu résistant, des chaussures
montantes et une coiffe.
Pour rechercher des fuites, utiliser de l’eau savonneuse ou
un détecteur à ultrasons, jamais les mains nues. En cas
de détection de fuite, ne pas utiliser l’équipement.
Remettre les portes, panneaux, recouvrements ou dispositifs
de protection quand l’entretien est terminé et avant de mettre
en marche l’appareil.
En cas d’injection d’air dans la peau ou le corps, demander
immédiatement une assistance médicale.
Demander seulement à un personnel qualifié d’enlever
les dispositifs de sécurité ou les recouvrements pour effectuer,
s’il y a lieu, des travaux d’entretien et de dépannage.
Remettre en place les portes, panneaux, recouvrements ou
dispositifs de protection à la fin des travaux d’entretien et avant
de mettre le moteur en marche.
LIRE LES INSTRUCTIONS.
Lire et appliquer les instructions sur les
étiquettes et le Mode d’emploi avant l’installation, l’utilisation ou l’entretien de l’appareil.
Lire les informations de sécurité au début du
manuel et dans chaque section.
N’utiliser que les pièces de rechange recommandées par le
constructeur.
Effectuer l’entretien en respectant les manuels d’utilisation, les
normes industrielles et les codes nationaux, d’état et locaux.
LE SOUDAGE À L’ARC ET LE
COUPAGE PLASMA risquent de
provoquer des interférences.
LE
RAYONNEMENT
HAUTE
FRÉQUENCE
(H.F.)
risque
de
provoquer des interférences.
Le rayonnement haute fréquence (H.F.) peut
provoquer des interférences avec les équipements de radio−navigation et de communication, les services de sécurité et les ordinateurs.
Demander seulement à des personnes qualifiées familiarisées
avec des équipements électroniques de faire fonctionner l’installation.
L’utilisateur est tenu de faire corriger rapidement par un électricien qualifié les interférences résultant de l’installation.
Si le FCC signale des interférences, arrêter immédiatement l’appareil.
Effectuer régulièrement le contrôle et l’entretien de l’installation.
Maintenir soigneusement fermés les portes et les panneaux des
sources de haute fréquence, maintenir les éclateurs à une distance correcte et utiliser une terre et un blindage pour réduire les
interférences éventuelles.
L’énergie électromagnétique peut gêner le
fonctionnement d’appareils électroniques sensibles comme des ordinateurs et des équipements commandés par ordinateur, tels que
des robots.
Veillez à ce que tout l’équipement de la zone de soudage soit
compatible au plan électromagnétique.
Pour réduire la possibilité d’interférence, maintenez les câbles
aussi courts que possible, groupez−les et posez−les aussi bas
que possible (ex. par terre).
Veillez à souder ou à couper à une distance de 100 mètres
de tout équipement électronique sensible.
Assurez−vous que le poste de soudage ou le découpeur plasma
est branché et mis à la terre conformément au présent manuel.
Si l’interférence persiste, l’utilisateur doit prendre des mesures
supplémentaires comme écarter le poste de soudage ou
le découpeur, en utilisant des câbles blindés, des filtres de ligne,
ou en protégeant la zone de travail.
2-5. Proposition californienne 65 Avertissements
Les équipements de soudage et de coupage produisent des
fumées et des gaz qui contiennent des produits chimiques
dont l’État de Californie reconnaît qu’ils provoquent des malformations congénitales et, dans certains cas, des cancers.
(Code de santé et de sécurité de Californie, chapitre 25249.5
et suivants)
Ce produit contient des produits chimiques, notamment du
plomb, dont l’État de Californie reconnaît qu’ils provoquent
des cancers, des malformations congénitales ou d’autres
problèmes de procréation. Se laver les mains après
utilisation.
2-6. Principales normes de sécurité
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
is available as a free download from the American Welding Society at
http://www.aws.org or purchased from Global Engineering Documents
(phone: 1-877-413-5184, website: www.global.ihs.com).
Safe Practices for the Preparation of Containers and Piping for Welding
and Cutting, American Welding Society Standard AWS F4.1, from Global Engineering Documents (phone: 1-877-413-5184, website:
www.global.ihs.com).
Safe Practices for Welding and Cutting Containers that have Held Combustibles, American Welding Society Standard AWS A6.0, from Global
Engineering Documents (phone: 1-877-413-5184,
website: www.global.ihs.com).
National Electrical Code, NFPA Standard 70, from National Fire Protection Association, Quincy, MA 02269 (phone: 1-800-344-3555, website:
www.nfpa.org and www. sparky.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 14501 George Carter Way, Suite
103, Chantilly, VA 20151 (phone: 703-788-2700, website:www.cganet.com).
Safety in Welding, Cutting, and Allied Processes, CSA Standard
W117.2, from Canadian Standards Association, Standards Sales, 5060
Spectrum Way, Suite 100, Ontario, Canada L4W 5NS (phone:
800-463-6727, website: www.csa-international.org).
Safe Practice For Occupational And Educational Eye And Face Protection, ANSI Standard Z87.1, from American National Standards Institute,
25 West 43rd Street, New York, NY 10036 (phone: 212-642-4900, website: www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, from National Fire Protection Association,
Quincy, MA 02269 (phone: 1-800-344-3555, website: www.nfpa.org.
OSHA, Occupational Safety and Health Standards for General Industry,
Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q, and
Part 1926, Subpart J, from U.S. Government Printing Office, Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954
(phone: 1-866-512-1800) (there are 10 OSHA Regional Offices—phone
for Region 5, Chicago, is 312-353-2220, website: www.osha.gov).
Applications Manual for the Revised NIOSH Lifting Equation, The National Institute for Occupational Safety and Health (NIOSH), 1600
Clifton Rd, Atlanta, GA 30333 (phone: 1-800-232-4636, website:
www.cdc.gov/NIOSH).
2-7. Informations relatives aux CEM
Le courant électrique qui traverse tout conducteur génère des champs
électromagnétiques (CEM) à certains endroits. Le courant issu d’un
soudage à l’arc (et de procédés connexes, y compris le soudage par
points, le gougeage, le découpage plasma et les opérations de
chauffage par induction) crée un champ électromagnétique (CEM)
autour du circuit de soudage. Les CEM peuvent créer des interférences
avec certains implants médicaux comme des stimulateurs cardiaques.
Pour les personnes portant des implants médicaux, il convient de
prendre des mesures de protection en limitant par exemple tout accès
aux passants ou procédant à une évaluation des risques individuels
pour les soudeurs. Tous les soudeurs doivent appliquer les procédures
suivantes pour minimiser l’exposition aux CEM provenant du circuit de
soudage:
a
Rassembler les câbles en les torsadant ou en les attachant avec
du ruban adhésif ou avec une housse.
b
Ne pas se tenir au milieu des câbles de soudage. Disposer les
câbles d’un côté et à distance de l’opérateur.
c
d
e
f
g
Ne pas courber et ne pas entourer les câbles autour de votre
corps.
Maintenir la tête et le torse aussi loin que possible du matériel du
circuit de soudage.
Connecter la pince sur la pièce aussi près que possible de la
soudure.
Ne pas travailler à proximité d’une source de soudage, ni
s’asseoir ou se pencher dessus.
Ne pas souder tout en portant la source de soudage ou le
dévidoir.
En ce qui concerne les implants médicaux :
Les porteurs d’implants doivent d’abord consulter leur médecin avant de
s’approcher des opérations de soudage à l’arc, de soudage par points,
de gougeage, du coupage plasma ou de chauffage par induction. Si le
médecin approuve, il est recommandé de suivre les procédures précédentes.
OM-260 545 Page 11
SECTION 3 − DEFINITIONS
3-1. Additional Safety Symbols And Definitions
Keep away from pinch points.
Safe110 2012−11
3-2. Miscellaneous Symbols And Definitions
On
A
V
Voltage
Off
Air Filter
Percent
Input Power Or
Input Voltage
Protective Earth
(Ground)
Cleaning
Required
Amperage
Cleaning In
Process
Line Connection
U1
I1
Primary Voltage
Rated Supply
Current
Alternating
Current (AC)
Notes
Work like a Pro!
Pros weld and cut
safely. Read the
safety rules at
the beginning
of this manual.
OM-260 545 Page 12
SECTION 4 − SPECIFICATIONS
4-1. Introduction
The Capture series of weld fume collectors incorporates a high-volume vacuum system that uses a high efficiency, nanofiber-media cartridge filter
to collect airborne weld fume particles. Weld fumes are captured at the source by a unit-mounted extraction arm. The extraction arm uses gas-shock
assisted friction joints and flexible tubing to ensure the hood is placed near the source of the fumes.
The weld fumes are first drawn into the arm through a mesh screen which prevents large sparks from passing into the filter housing. The fumes then
pass through the filter where particles are filtered from the air. Cleaned air flows through the center of the filter and into the blower housing. The blower
housing discharges the clean air from the perimeter of the hood (to establish the fume capture zone) and from the back of the unit.
An adjustable air control dial allows the user to regulate the amount of clean air discharged from the perimeter of the hood to create the most effective
fume extraction zone for the work environment.
The weld fume collector includes a semi-automatic filter cleaning system to remove particles from the filter. When the Cleaning Cycle is initiated either
manually or automatically, compressed air removes particles from the filter. The particles then fall into a collection tray at the bottom of the unit.
The weld fume collector comes partially assembled and can be used with a 10 Ft. (3 m) or 12 ft. (3.7 m) extension extraction arm.
2
5
1
1
2
3
4
5
6
7
8
Hood
Capture Arm
Air Baffle and Spark Tray
Filter
Air Discharge Vent
Particle Tray
Caster w/Brake
3/8 NPT Compressed Air
Fitting
9 Input Power Receptacle
10 Push bar
11 Air Control Dial
3
11
5
10
4
8
6
9
7
260 889-C
4-2. Serial Number And Rating Label Location
The serial number and rating information is located on the front of the unit. Use rating label to determine input power requirements and/or rated
output. For future reference, write serial number in space provided on back cover of this manual.
4-3. Fume Extractor Specifications
Input Power
Nominal Air Flow
Motor
Filter Area
Or
575 Volts AC, 3 A
Weight
Dimensions
Cart:
555 lb (252 kg)
Single-Phase Model
208-230 Volts AC
14.6/13.5 A
Three-Phase Models:
460 Volts AC, 3.7 A
Sound Level
77 dBa
900 CFM
(425 liter/sec)
3 HP
(2.24 kW)
452 ft2
(42 m2)
AMCA Tested
Sound Level At
5 ft (1.5 m)
Cart w/XD-10 Arm
Model:
650 lb (295 kg)
48 x 36 x 43 in.
(122 x 91.4 x 109 cm)
Cart w/XD-12 Arm
Model:
660 lb (299 kg)
OM-260 545 Page 13
4-4. Extraction Arm Specifications
Model
Weight
XD-10
XD-12
Arm Reach
Arm Diameter
95 lb (43 kg)
10 ft (3 m)
10 in. (254 mm)
105 lb (48 kg)
12 ft (3.7 m)
10 in. (254 mm)
4-5. Fume Capture Zone
The fume capture zone represents the maximum size and
shape of the fume withdrawal
area in normal conditions (open
room with no air movement) and
with air control dial in max position.
5 ft. (1.5 m)
The actual fume capture zone
may be smaller than that shown.
Improper placement of
Maximum
Fume Extraction
Zone
4 ft. (1.2 m)
the
extraction arm may affect
shielding gas in the weld
zone and negatively impact
weld quality.
260 889-C
Capture Zone Air Flow And Pressure Differential
Air Flow
Positive Pressure
High Negative Pressure
OM-260 545 Page 14
SECTION 5 − INSTALLATION
5-1. Selecting A Location
!
Do not move or operate unit
where it could tip.
!
Do not use this equipment to
support personnel, large
tools, or other material.
!
Special installation may be required where gasoline or volatile liquids are present − see
NEC Article 511 or CEC Section 20.
Unit shown with extraction arm
already installed.
1
2
3
1
Lifting Forks
Caster w/Brake
Power Supply − Line
Disconnect Device For:
Single-Phase, 208-230 Volt AC
Models
Extend lifting forks
beyond center of skid.
OR
Three-Phase, 460 Volt AC Or
575 Volt AC Models.
4
Compressed Air Supply
(80−100 psi/3.8−4.8 kPa)
Use wheels or lifting forks to move
unit.
3
4
If using lifting forks, extend forks beyond opposite side of small containers and beyond midpoint of large/
long containers.
Position unit near the welding operation and close to compressed air supply and AC input power supply. Keep
unit away from obstructions that may
restrict movement of the fume collector or extension arm.
A single-phase 208-230 volt AC,
18 in.
(460 mm)
three-phase, 460 volt AC, or
three-phase 575 volt AC individual branch circuit protected by
time delay (type D) fuses or circuit breaker is required.
2
800 402-A / 260 887-C / 161-016
OM-260 545 Page 15
5-2. Tipping
!
Do not move or operate unit
where it could tip.
!
Do not move unit with extraction arm extended or unit
may tip.
!
Do not move unit by pulling
on extraction arm or equipment may tip. Use handle on
fume extractor to move unit
!
Do not use this equipment to
support personnel, large
tools, or other material.
5-3. Lifting Extraction Arm
!
Use equipment of adequate
capacity to lift and support
unit.
NOTICE − With extraction arm vertically aligned, carefully guide extraction arm tube into cart to avoid
damaging gasket and other components.
Stabilize
fume extractor by
locking front wheels (casters).
Lift Here.
1
Extraction Arm Assembly
Position lifting device on extraction
arm at location shown. Lift extraction arm onto cart. See Section 5-4.
Tools Needed:
1
264 213-A
OM-260 545 Page 16
5-4. Installing Extraction Arm Base Assembly
!
Turn Off and disconnect input power.
Stabilize
fume extractor by
locking front wheels (casters).
After installing extraction arm on cart,
1
2
3
remove pin so arm moves freely.
Base Assembly
3/8 in. Screw
3/8 in. Flat Washer
Place base assembly on cart. Secure base assembly with supplied
hardware. Tighten hardware to 3.0
ft lb (4.0 N⋅m).
Tools Needed:
9/16 in.
2
3
1
Cart
260 882-C / 264 213-A / 260 983-A
OM-260 545 Page 17
5-5. Connecting To Compressed Air Supply
!
Shut off air supply before
disconnecting or connecting
air hose.
!
Wear protective equipment
when disconnecting compressed air supply. Internal
air tank is under pressure
and will discharge when air
supply is disconnected.
!
Latch filter and close door
before starting unit or operating filter cleaning system.
!
Do not direct air stream toward self or others.
!
If ANY air is injected into the
skin or body seek medical
help immediately.
1
3/8 NPT Compressed Air
Fitting
Compressed Air Supply (80 −
100 psi / 3.8 − 4.8 kPa)
Air Hose
2
3
2
3
Install customer-supplied compressed air fitting in 3/8 NPT fitting
on front of unit.
Connect customer-supplied air
hose to fitting when Filter Pressure
gauge indicates cleaning is required.
Tools Needed:
1
260 887-C
OM-260 545 Page 18
5-6. Wiring Input Power Plug For Single-Phase Models (NEMA L6-30C)
X Terminal
Y Terminal
2
3
G Terminal
1
Plug 6 2014 -11 269 690-A
!
1
Installation must meet all National and
Local Codes − have only qualified persons make this installation.
Input Power Cord
Select cord according to Section 5-8.
2
250 V AC, Single-Phase, 30 A, 2P3W
Plug (NEMA L6-30C) (Supplied)
3 Cord Grip
Strip insulation from end of each wire in cord
and connect wires to plug as
follows:
• Green Or Green/Yellow Wire To G Terminal
• Black Wire To X Terminal
• White Wire To Y Terminal
Reinstall outer shell and cord grip.
5-7. Wiring Input Power Plug For Three-Phase Models (NEMA L16-20C Or L17-30C)
X Terminal
Y Terminal
2
3
Z Terminal
G Terminal
1
Ref. Plug 5 2014 -11 261 487-A
!
Installation must meet all National
and Local Codes − have only qualified persons make this installation.
1
Input Power Cord
Select cord according to Section 5-8.
2
480 V AC, Three-Phase, 20 A, 3P4W
Plug (NEMA L16-20C) (Supplied)
OR
600 V AC, Three-Phase, 30A 3P4W
Plug (NEMA L17-30C) (Supplied)
3 Cord Grip
Strip insulation from end of each wire in cord
and connect wires to plug as follows:
• Green Or Green/Yellow Wire To G Terminal
• Black Wire To X Terminal
• White Wire To Y Terminal
• Red Wire To Z Terminal
Reinstall outer shell and cord grip.
OM-260 545 Page 19
5-8. Electrical Service Guide
Ref. Elec Serv 2014-01
Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommendations are for a dedicated circuit sized for the rated output and duty cycle of the fume extractor.
60 Hz Single- Phase
60 Hz Three-Phase
Input Voltage (V)
208
230
460
575
Input Amperes (A) At Rated Output
14.6
13.5
3.7
3
5-9. Connecting Single-Phase Input Power
1
3
=GND/PE Earth Ground
7
2
4
L1
L2
5
6
1
9
8
Ref. Input 11 2014−11 / 260 880-A
!
Installation must meet all National
and Local Codes − have only qualified persons make this installation.
! Disconnect and lockout/tagout input power before connecting input
conductors from unit. Follow established procedures regarding the installation and removal of lockout/
tagout devices.
! Always connect green or green/yellow conductor to supply grounding
terminal first, and never to a line terminal.
! Do not use the fume extraction
equipment unless you are sure it is
correctly assembled and working
properly.
See rating label on unit and check input voltage available at site.
OM-260 545 Page 20
1
Input Power Conductors (Customer
Supplied Cord)
Select size and length of conductors based
on information in Section 5-8. Conductors
must comply with national, state, and local
electrical codes. If applicable, use lugs of
proper amperage capacity and correct hole
size.
Disconnect Device Input Power
Connections
2 Disconnect Device (switch shown in
OFF position)
3 Disconnect Device (Supply)
Grounding Terminal
4 Disconnect Device Line Terminals
5 Input Conductor L1 (X) And L2 (Y)
6 Green Or Green/Yellow Grounding
Conductor
Connect green or green/yellow grounding
conductor to disconnect device grounding
terminal first.
Connect input conductors L1 (X) and L2 (Y)
to disconnect device line terminals.
7
Over-Current Protection
Select type and size of over-current protection based on information in Section 5-8
(fused disconnect switch shown).
8
Input Power Plug
See Section 5-6.
9
Input Power Receptacle
Connect input power plug to input power receptacle.
Close and secure door on line disconnect
device. Follow established lockout/tagout
procedures to put unit in service.
5-10. Connecting Three-Phase Input Power
3
=GND/PE Earth Ground
3
2
7
4
6
5
1
9
8
Ref. Input 8 2014−11 / 260 889-C / 261 487-A
!
Installation must meet all National
and Local Codes − have only qualified persons make this installation.
!
Disconnect and lockout/tagout input power before connecting input
conductors from unit. Follow established procedures regarding the installation and removal of lockout/
tagout devices.
!
Always connect green or green/yellow conductor to supply grounding
terminal first, and never to a line terminal.
!
Do not use the fume extraction
equipment unless you are sure it is
correctly assembled and working
properly.
See rating label on unit and check input voltage available at site.
1
Input Power Conductors (Customer
Supplied Cord)
Select size and length of conductors based
on information in Section 5-8. Conductors
must comply with national, state, and local
electrical codes. If applicable, use lugs of
proper amperage capacity and correct hole
size.
Disconnect Device Input Power
Connections
2 Disconnect Device (switch shown in
OFF position)
3 Disconnect Device (Supply)
Grounding Terminal
4 Disconnect Device Line Terminals
5 Input Conductors L1 (X), L2 (Y), And
L3 (Z)
6 Green Or Green/Yellow Grounding
Conductor
Connect green or green/yellow grounding
conductor to disconnect device grounding
terminal first.
Connect input conductors L1 (X), L2 (Y)
And L3 (Z) to disconnect device line
terminals.
7 Over-Current Protection
Select type and size of over-current protection based on information in Section 5-8
(fused disconnect switch shown).
8 Input Power Plug
See Section 5-7.
9 Input Power Receptacle
(Machine-Mounted)
Connect input power plug to input power receptacle.
Close and secure door on line disconnect
device. Follow established lockout/tagout
procedures to put unit in service.
OM-260 545 Page 21
SECTION 6 − OPERATION
6-1. Controls
4
5
1
3
2
260 882-C / 261 582-A
!
1
Only use the fume extractor to extract weld fumes. Do not use the
fume extractor to extract hot gases
(above 140° F/60° C), wood or cement dust, engine exhaust, liquid
vapors,
explosive
materials,
aggressive fumes (acid), fumes
from burning objects, or fumes from
cleaning, cutting, gouging, grinding, painting, flame spraying, sand
blasting, or other non-welding operations.
Power Switch
tween 0.1 and 0.5 in. w.c. at start-up (with
a new filter).
length of the fume capture zone (see Section 4-5).
3
Improper placement of
Filter
cleaning cycle automatically
starts every time the machine is turned
off to maximize filter life.
Use switch to turn unit On and Off, and to
interrupt filter cleaning cycle.
2
Filter Pressure Gauge
Gauge only indicates air pressure drop
across the filter. Clean or replace filter
when Cleaning Cycle button is flashing
blue, Filter Pressure gauge reading is over
4 in. w.c., or whenever air flow is too low to
extract fumes. The gauge should read be-
OM-260 545 Page 22
Cleaning Cycle Button
Press button to manually operate filter
cleaning system. Button is illuminated during cleaning cycle. Clean or replace filter
when Cleaning Cycle button is flashing
blue, Filter Pressure gauge reading is over
4 in. w.c., or whenever air flow is too low to
extract fumes. (See Sections 7-4 and 7-5
for filter maintenance information).
4
Hood
Position the hood to minimize the effects of
cross drafts from outside air sources or
from other operations. Tilt the hood at a 30°
angle and position it as close to the welding
arc as possible; the distance from the hood
to the arc must not exceed the effective
the extraction
arm may affect shielding gas in the
weld zone and negatively impact weld
quality.
5
Air Control Dial
Use Air Control dial to regulate the amount
of clean air discharged from the perimeter
of the hood to create the most effective
fume extraction zone for the work environment.
Rotate dial toward Max position to expand
the size of the fume extraction zone. Higher
settings are recommended for open work
areas.
Rotate dial toward Min position to decrease
the size of the extraction zone. Lower settings are recommended for confined work
areas.
6-2. Prestart Checklist (Before Welding)
!
Do not use the fume extraction
equipment unless you are sure
it is correctly assembled and
working properly.
Check for free and easy movement of the extraction arm and
swivel base before each use.
1
2
Clean Air Outlets
Filter Pressure Gauge
Verify clean air outlets are not obstructed and discharge air appears
clean (free of welding fumes). Check
gaskets on access door and back of
filter. Replace gasket(s) if damaged.
Check filter if discharge air appears
dirty. Make sure filter is latched and
door is closed to ensure a tight seal
around the filter.
The safety interlock system pre-
1
vents unit from starting if filter is
not properly latched.
Check Filter Pressure gauge. Clean
or replace filter when Cleaning Cycle
button is flashing blue, Filter Pressure
gauge reading is over 4 in. w.c., or
whenever air flow is too low to extract
fumes.
Filter cleaning cycle automatical-
ly starts every time the machine is
turned off to maximize filter life.
1
2
260 889-C / 260 905-C
OM-260 545 Page 23
SECTION 7 − USER SERVICING INSTRUCTIONS (MAINTENANCE)
7-1. Routine Maintenance
!
Disconnect Power before maintaining.
Service equipment more often if used in severe conditions.
= Check
= Change
= Clean
= Replace
* To be done by Factory Authorized Service Agent
Daily
Every
Month
Filter Pressure
gauge. Clean or
replace filter if
necessary (Section
7-4)
Free Movement Of
Arm Base Assembly
Extraction Arm Hood
And Joints Stay In
Position
Outer Surfaces
Every
3
Months
Unreadable Labels
Inside of Extraction
Arm With Warm
Water And
Detergent
Fume Extractor
Spark Tray (see
Section 7-5)
Inside Unit
* Motor Bearing
Lubrication.
Grease Bearings
Every 5500 Hours
Of Operation.
Filter
Every
6
Months
OM-260 545 Page 24
Gaskets On Door,
Particle Tray
Extraction Arm Ducts
And Tubing
Inner Surface
Of Hood
7-2. Overload Protection On 230 Volt Single-Phase Models
2
1
Tools Needed:
261 118-E
!
Turn off power and disconnect input
power cord.
2
1
Circuit Breaker CB1
(See Parts List For Rating)
F1, F2, and F3 protect the controller and internal power supply from overload. If any of
these fuses open the unit does not operate.
Check fuse(s) and replace if open.
CB1 protects the blower motor from overload. If CB1 opens the unit does not operate.
Check breaker and reset if open.
Fuses F1, F2, And F3
(See Parts List For Rating)
To access circuit breaker and fuses, re-
move the four screws securing the front
nameplate. Reinstall nameplate after
checking circuit breaker and fuses.
If a circuit breaker or fuse opens, it usually indicates a more serious problem
exists. Contact a Factory Authorized
Service Agent.
Notes
Work like a Pro!
Pros weld and cut
safely. Read the
safety rules at
the beginning
of this manual.
OM-260 545 Page 25
7-3. Overload Protection On 460 Volt And 575 Volt Three-Phase Models
460 Volt Model
575 Volt Model
3
1
2
3
Tools Needed:
261 118-E
!
Turn off power and disconnect input
power cord.
1 Circuit Breaker CB1 (460 V Model)
(See Parts List For Rating)
CB1 protects the blower motor from overload. If CB1 opens the unit does not operate.
Check breaker and reset if open.
2 Fuses F1, F2, And F3
(See Parts List For Rating)
OM-260 545 Page 26
F1, F2, and F3 protect the controller and internal power supply from overload. If any of
these fuses open the unit does not operate.
Check fuse(s) and replace if open.
3 Fuses F4, F5, F6 (575 V Model)
(See Parts List For Rating)
Protect the blower motor from overload. If
any of the fuses are open, the unit will not
operate. Check fuse(s) and replace if open.
To access circuit breaker and fuses, remove the four screws securing the front
nameplate. Reinstall nameplate after
checking circuit breaker and fuses.
If a circuit breaker or fuse opens, it usually indicates a more serious problem
exists. Contact a Factory Authorized
Service Agent.
7-4. Cleaning Filter And Emptying Particle Tray
!
Latch filter and close door before
starting unit or operating filter
cleaning system.
!
Do not operate unit without filter or
with dirty filter.
!
Clean or replace filter when dirty.
!
Allow cooling period before inspecting or replacing filter, or cleaning
particle tray and spark tray.
!
Do not breathe the particles collected by the fume extractor. Wear
approved safety equipment (respirator, gloves, long sleeve shirt)
when servicing filter and spark tray.
Dispose of used element and collected particles according to local,
state, and federal requirements.
!
If ANY air is injected into the skin or
body seek medical help immediately.
!
Read and understand the Safety
Data Sheets (SDSs) and the
manufacturer’s instructions for
metals, consumables, coatings,
cleaners, and degreasers.
1
See Section 5-5 for compressed air requirements for proper filter cleaning.
!
Wear protective equipment when
disconnecting compressed air supply. Internal air tank is under pressure and will discharge when air
supply is disconnected.
1
Cleaning Cycle Button
Press button to operate filter cleaning system. Clean or replace filter when Cleaning
Cycle button is flashing blue, Filter Pressure gauge reading is over 4 in. w.c., or
whenever air flow is too low to extract
fumes. Keep filter latched and door closed
during cleaning to maintain a tight seal
around filter.
To manually clean filter, press and release
Cleaning Cycle button. The filter cleaning
system operates only when the unit is off.
Filter
cleaning cycle automatically
starts every time the machine is turned
off to maximize filter life.
The system cleans the filter in about 60
seconds. Wait until the cleaning has
stopped and particles have settled before
removing particles from tray.
2
3
Particle Tray
Particle Tray Handle
Release latches and open door. Pull out
tray and remove particles. Reinstall tray
when finished.
Tools Needed:
3
2
Inspect filter after cleaning (Section 7-5).
Start unit and check Filter Pressure gauge
reading.
!
Replace filter if, after cleaning, Filter
Pressure gauge reading is over 4 in.
w.c. or air flow is too low to extract
fumes.
260 905-C / 260 950-C
OM-260 545 Page 27
7-5. Inspecting Filter And Spark Tray
1
!
Turn off power and disconnect input power cord.
!
Do not operate unit without filter or with dirty filter.
!
Clean or replace the filter
when dirty.
!
Allow cooling period before
inspecting or replacing filter,
or cleaning particle tray and
spark tray.
!
Do not breathe the particles
collected by the fume extractor. Wear approved safety
equipment (respirator, gloves,
long sleeve shirt) when servicing filter and spark tray.
Dispose of used element and
collected particles according
to local, state, and federal requirements.
!
Read and understand the
Safety Data Sheets (SDSs)
and the manufacturer’s instructions for metals, consumables, coatings, cleaners,
and degreasers.
1
2
3
Door
Filter
Spark Tray
2
Release latches and open door. Released latches on filter. Use filter
handle to remove filter.
Clean or replace filter if dirty or damaged.
Wipe off door. Remove particles from
inside of housing.
3
Locate spark tray above filter. Use
handle on spark tray to remove tray
from unit.
Clean and inspect spark tray. Reinstall tray when finished.
Check gaskets on access door,
particle tray, and front and back of filter. Replace gasket(s) if damaged.
Install filter and secure with latches.
Verify filter is securely latched.
The safety interlock system prevents unit from starting if filter is
not properly latched.
Close door and secure with latches.
Tools Needed:
260 950-B
OM-260 545 Page 28
7-6. Adjusting Extraction Arm Joints
!
Support extraction arm
when making adjustments.
!
Elbow joints are under tension. Keep away from pinch
points when making adjustments.
When properly adjusted, the extraction arm should move easily but
not slip from position.
1
1
1
T-Handle Knob
Use knobs to maintain arm position
by increasing or decreasing joint
friction.
1
260 897-A
SECTION 8 − TROUBLESHOOTING
8-1. Troubleshooting Table
Trouble
Remedy
Motor/blower will not start or continue Check input power connection (see Section 5-10).
running.
Verify filter is securely latched. Safety interlock system prevents unit from starting if filter is not properly latched.
All models: check fuses F1, F2, and F3, and replace if open (see Sections 7-2 and 7-3).
230 volt and 460 volt models: check circuit breaker CB1. Reset CB1 if open (see Sections 7-2 and
7-3).
575 volt models: check fuses F4, F5, and F6, and replace if open (see Section 7-3).
Have Factory Authorized Service Agent check motor and wiring.
Decreased air flow.
Reconnect extraction arm flexible tubing. Check inner tubing by first pulling back outer tubing.
Inspect extraction arm tubing and replace if damaged.
Remove obstructions from fume extraction arm.
Remove debris from spark tray (see Section 7-5).
Clean or replace filter (see Sections 7-4 and 7-5).
Have Factory Authorized Service Agent check for correct fan rotation (counterclockwise as viewed
from back of unit).
Filter cleaning system does not
operate.
All models: check fuses F1, F2, and F3, and replace if open (see Sections 7-2 and 7-3).
230 volt and 460 volt models: check circuit breaker CB1. Reset CB1 if open (see Sections 7-2 and
7-3).
575 volt models: check fuses F4, F5, and F6, and replace if open (see Section 7-3).
Verify filter is securely latched. Safety interlock system prevents unit from starting if filter is not properly latched.
Fume extractor discharges fumes or
particles.
Inspect filter (including gasket) and replace if damaged or dirty. Be sure filter is installed properly (see
Section 7-5).
Extraction arm does not stay in
position.
Adjust extraction arm joints (see Section 7-6).
Extraction arm does not turn easily.
Verify hardware securing extraction arm to base is properly tightened (see Section 5-4).
OM-260 545 Page 29
SECTION 9 − ELECTRICAL DIAGRAMS
269 685-A
Figure 9-1. Circuit Diagram For Single-Phase 230 V Model
OM-260 545 Page 30
267 907-A
Figure 9-2. Circuit Diagram For Three-Phase 460 V Model
OM-260 545 Page 31
267 908-A
Figure 9-3. Circuit Diagram For Three-Phase 575 V Model
OM-260 545 Page 32
SECTION 10 − PARTS LIST
Hardware is common and
14
not available unless listed.
16
20
15
25
21
19
13
24
26
23
27
28
12
18
11
29
10
9
17
31
30
32
6 − Figure10-3 Or
Figure 10-4
8
33
22
34
7
35
37
36
38
39
2
48
47
See Fig10-2
55
See
Fig10-2
5
49
50
27
19
40
4
3
41
44
1
54
52
42
43
46
53
51
45
264 102-D
Figure 10-1. Main Assembly
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 10-1. Main Assembly
. . . 1 . . . . . . . . . . . . . +260183 . . Panel, Cart Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 2 . . . . . . . . . . . . . . 260981 . . Label, Warning Compressed Air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 3 . . . . . . . . . . . . . . 269778 . . Connector, Panel Mount Male 250V, 30A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single-Phase L6-30I (230 Volt Model) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 3 . . . . . . . . . . . . . . 260592 . . Connector, Panel Mount Male 480V 20A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Three-Phase L16−20I (460 Volt Model) . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 3 . . . . . . . . . . . . . . 265219 . . Connector, Panel Mount Male 600V 30A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Three-Phase L17−30I (575 Volt Model) . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 4 . . . . . . . . . . . . . . 269689 . . Connector, Socket Female 250V 30A 1 Phase L6−30C (230V Model) . .
. . . 4 . . . . . . . . . . . . . . 261139 . . Connector, Socket Female 480V 20A 3 Phase L16−20C (460V Model) .
. . . 4 . . . . . . . . . . . . . . 265220 . . Connector, Socket Female 600V 30A 3 Phase L17−30C (575V Model) .
. . . 5 . . . . . . . . . . . . . . 260196 . . Coupling, Blkhd Brs 3/8 NPT(F) X 1.000 Mtg Hole . . . . . . . . . . . . . . . . . . .
. . . 6 . . . . . . . . . . Figure 10-3 . . Control Box Assembly, Single-Phase Model . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 6 . . . . . . . . . . Figure 10-4 . . Control Box Assembly, Three-Phase Models . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
1
1
1
1
1
1
1
1
OM-260 545 Page 33
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 10-1. Main Assembly (Continued)
. . . 7 . . . . . . . . . . . . . . 260424
. . . 8 . . . . . . . . . . . . . . 268964
. . . 9 . . . . . . . . . . . . . . 260511
. . . 10 . . . . . . . . . . . . . . 269293
. . . 11 . . . . . . . . . . . . . . 269294
. . . 12 . . . . . . . . . . . . . . 269296
. . . 13 . . . . . . . . . . . . . . 269282
. . . 14 . . . . . . . . . . . . . . 269284
. . . 15 . . . . . . . . . . . . . . 269283
. . . . . . . . . . . . . . . . . . . . 269298
. . . 16 . . . . . . . . . . . . . . 260475
. . . 17 . . . . . . . . . . . . . . 260552
. . . 18 . . . . . . . . . . . . . +260421
. . . 19 . . . . . . . . . . . . . . 246340
. . . 20 . . . . . . . . . . . . . . 260422
. . . 21 . . . . . . . . . . . . . . 260184
. . . 22 . . . . . . . . . . . . . . 261417
. . . 23 . . . . . . . . . . . . . . 260594
. . . 24 . . . . . . . . . . . . . . 260347
. . . 25 . . . . . . . . . . . . . . 268955
. . . 26 . . . . . . . . . . . . . . 268954
. . . 27 . . . . . . . . . . . . . . 269295
. . . 28 . . . . . . . . . . . . . . 268965
. . . 29 . . . . . . . . . . . . . . 268958
. . . 30 . . . . . . . . . . . . . . 260829
. . . 31 . . . . . . . . . . . . . . 249623
. . . 32 . . . . . . . . . . . . . . 244555
. . . 33 . . . . . . . . . . . . . *301106
. . . . . . . . . . . . . . . . . . . . 268956
. . . 34 . . . . . . . . . . . . . . 268958
. . . 35 . . . . . . . . . . . . . . 268957
. . . 36 . . . . . . . . . . . . . . 268951
. . . 37 . . . . . . . . . . . . . . 268959
. . . 38 . . . . . . . . . . . . . . 260420
. . . 39 . . . . . . . . . . . . . . 259925
. . . 40 . . . . . . . . . . . . . . 268949
. . . 41 . . . . . . . . . . . . . . 263859
. . . 42 . . . . . . . . . . . . . . 269793
. . . 43 . . . . . . . . . . . . . . 602250
. . . 44 . . . . . . . . . . . . . . 269811
. . . 45 . . . . . . . . . . . . . . 269796
. . . 46 . . . . . . . . . . . . . +260418
. . . 47 . . . . . . . . . . . . . . 260516
. . . 48 . . . . . . . . . . . . . . 260123
. . . 49 . . . . . . . . . . . . . . 260515
. . . 50 . . . . . . . . . . . . . . 260526
. . . 51 . . . . . . . . . . . . . . 268950
. . . 52 . . . . . . . . . . . . . . 269798
. . . 53 . . . . . . . . . . . . . . 269809
. . . 54 . . . . . . . . . . . . . . 263925
. . . 55 . . . . . . . . . . Figure 10-2
+
. . Panel, Cart Control Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Bracket, Motor Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Handle, Cart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Panel, Cart Top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Panel, Tool Tray Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Label, Capture Zone Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Bushing, Bronze .625 OD x .375 ID x .500 LG . . . . . . . . . . . . . . . . . . . . . . . 1
. . Plunger, Zone Flow Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Plate, Zone Flow Control (Includes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
..
Label, Zone Flow Control Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Plate, Arm Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Panel, Cart Rear Louvers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Panel, Cart Left Side B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Label, Warning General Precautionary (Eng/Fr) . . . . . . . . . . . . . . . . . . . . . 2
. . Panel, Cart Left Side C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Panel, Cart Left Side A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Clamp, Toggle Vertical 307−U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . Hinge, 50mm X 50mm W/Countersunk Forms For M6 . . . . . . . . . . . . . . . . 2
. . Gasket, Foam Flame Retardant .50 Wide X .25 Thk . . . . . . . . . . . . . . . . 8 Ft.
. . Bracket, Spark Tray Compression . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Door, Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Latch, Draw Capture 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . Tray Assembly, Slide Out (Includes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Handle, Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Plate, Sealing Spark Arrestor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Baffle, Spark Arrestor Center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Plate, Sealing Spark Arrestor Rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Filter, Replacement Capture 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Assy, Dust Tray (Includes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Handle, Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Dust Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Panel, Cart Rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Bracket, Filter Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . Panel, Cart Right Side C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Plate, Backing Draw Latch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . Panel, Cart Right Side A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Wheel, Rbr 10.000 OD X 2.000 Wd X .750 Bore Blk Hub . . . . . . . . . . . . . 2
. . Screw, Shld Stl Sch .625−11 X .750 X 4.00 Shld . . . . . . . . . . . . . . . . . . . . . 2
. . Washer, Flat .812IDx1.469ODx.134t Stl Pld Ansi.750 . . . . . . . . . . . . . . . . 4
. . Spacer, Wheel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . Panel, Fender Flare . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . Panel, Cart Right Side B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Bracket, Slide Tray Left . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Slide, Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
. . Bracket, Slide Tray Right . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Bracket, Slide Tray Center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Panel, Cart Bottom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Panel, Cart Caster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Caster Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Caster, Swvl 5.00 in. X 2.00 in. Wide w/Brake . . . . . . . . . . . . . . . . . . . . . . . 2
. . Blower Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
When ordering a component originally displaying a precautionary label, the label should also be ordered.
* Recommended Spare Parts.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-260 545 Page 34
23
19
Hardware is common and
not available unless listed.
24
22
18
24
20
21
17
16
14
13
32
15
12
31
11
44
30
25
29
26
9
10
8
41
42
28
33
27
43
45
40
39
38
34
7
46
37
6
35
5
4
3
2
36
1
264 101-C
Figure 10-2. Blower Assembly
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 10-2. Blower Assembly (Figure 10-1, Item 55)
...
...
...
...
...
...
...
...
...
1
2
3
4
5
6
7
7
7
..............
..............
..............
..............
..............
..............
. . . . . M1 . . . . .
. . . . . M1 . . . . .
. . . . . M1 . . . . .
260608
260593
260922
260924
023562
260980
269277
269275
269276
..
..
..
..
..
..
..
..
..
Receiver, Tank Pulse Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Valve, Air Pulse 1 NPT(M) W/Compressed Seal . . . . . . . . . . . . . . . . . . . . .
Ftg, Pipe Galv Elbow St .375 NPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ftg, Pipe Stst Barbed Hex .375 Tbg X 3/8 NPT(M) . . . . . . . . . . . . . . . . . . .
Clamp, Hose .312 − .875 Clp Dia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hose, 0.375 ID X 0.719 OD X 12.00 In Lg 500 PSI . . . . . . . . . . . . . . . . . . .
Motor, Blower 3 HP 3450 RPM 230 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Motor, Blower 3 HP 3450 RPM 460 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Motor, Blower 3 HP 3450 RPM 575 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
3
1
2
2
1
1
1
1
OM-260 545 Page 35
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 10-2. Blower Assembly (Figure 10-1, Item 55) (Continued)
. . . 8 . . . . . . . . . . . . . . 260134 . . Clamp, Hose 4.12 − 7.00 Clp Dia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . 9 . . . . . . . . . . . . . . 269280 . . Hose, 6.000 ID x 4.000 LG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 10 . . . . . . . . . . . . . . 262649 . . Flapper, Air Bleed Out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 11 . . . . . . . . . . . . . . 269281 . . Shaft, Air Bleed−Out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 12 . . . . . . . . . . . . . . 260154 . . Elbow, Air Bleed Out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 13 . . . . . . . . . . . . . . 260831 . . Grommet, Rbr .438 Panel Hole Dia X .094 Panel Thk . . . . . . . . . . . . . . . . 2
. . . 14 . . . . . . . . . . . . . . 262647 . . Hose, 6.00 ID X 3.00 Lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 15 . . . . . . . . . . . . . . 262624 . . Bracket, Manifold Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 16 . . . . . . . . . . . . . . 260111 . . Air Manifold, Cart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 17 . . . . . . . . . . . . . . 261073 . . Ftg, Conn Elbow 1/8 NPT(M) X 3/16 Tubing . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 18 . . . PROX1 . . . 263946 . . Switch, Proximity 4 mm Range X 12 mm Thread . . . . . . . . . . . . . . . . . . . . 1
. . . 19 . . . . . . . . . . . . . . 073433 . . Ftg, Connector 1/4 NPT (M) X 3/16 Tubing . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 20 . . . . . . . . . . . . . . 247772 . . Bushing, Reducing 1/4 x 1/8 NPT ZC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 21 . . . . . . . . . . . . . . 260187 . . Panel, Cart Manifold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 22 . . . . . . . . . . . . . . 262449 . . Collar Assy, 7.594 Dia (Includes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 23 . . . . . . . . . . . . . . 261105 . . . . . . Seal, Rubber D−Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 In.
. . . 24 . . . . . . . . . . . . . . 260931 . . Arm Support Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 25 . . . . . . . . . . . . . . 260683 . . Ftg, Pipe Galv Sch40 Nipple 1.000 NPT X 4.000 . . . . . . . . . . . . . . . . . . . . 1
. . . 26 . . . . . . . . . . . . . . 260604 . . Ftg, Pipe Galv Sch40 Nipple 1.000 NPT X 5.000 . . . . . . . . . . . . . . . . . . . . 1
. . . 27 . . . . . . . . . . . . . . 260684 . . Ftg, Pipe Galv Sch40 Nipple 1.000 NPT X 3.000 . . . . . . . . . . . . . . . . . . . . 1
. . . 28 . . . . . . . . . . . . . . 260559 . . Ftg, Pipe Galv Tee 1.000 NPT(F) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
. . . 29 . . . . . . . . . . . . . . 260596 . . Ftg, Pipe Galv Sch40 Nipple 3/4 NPT X 8.000 . . . . . . . . . . . . . . . . . . . . . . . 3
. . . 30 . . . . . . . . . . . . . . 260930 . . Ftg, Pipe Galv Bushing 1.000 NPT(M) X 3/4 NPT(F) . . . . . . . . . . . . . . . . . 6
. . . 31 . . . . . . . . . . . . . . 260597 . . Ftg, Pipe Galv Elbow 90deg 1.000 NPT(F) X 1.000 NPT . . . . . . . . . . . . . . 5
. . . 32 . . . . . . . . . . . . . . 260606 . . Nozzle, Pulse Cleaning 1.000 NPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
. . . 33 . . . . . . . . . . . . . . 268962 . . Bracket, Mtg Spark Tray A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 34 . . . . . . . . . . . . . . 268961 . . Bracket, Mtg Spark Tray B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 35 . . . . . . . . . . . . . . 264337 . . Baffle, Particulate Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 36 . . . . . . . . . . . . . . 260499 . . Funnel Tray, Front/Rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 37 . . . . . . . . . . . . . . 260215 . . Hose, 1.000 ID X 1.343 OD X 16.750 Lg 100 PSI . . . . . . . . . . . . . . . . . . . . 1
. . . 38 . . . . . . . . . . . . . . 010860 . . Clamp, Hose .750 − 1.750 Clp Dia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
. . . 39 . . . . . . . . . . . . . . 260595 . . Ftg, Pipe Brs Barbed Hex 1.000 Tbg X 1.000 NPT(M) . . . . . . . . . . . . . . . . 6
. . . 40 . . . . . . . . . . . . . . 260598 . . Ftg, Pipe Galv Elbow St 1.000 NPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
. . . 41 . . . . . . . . . . . . . . 265898 . . Screen, Inlet Blower (Includes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . 261692 . . . . Edge Trim, Screen Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 In.
. . . 42 . . . . . . . . . . . . . . 256142 . . Bracket, Inlet Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 43 . . . . . . . . . . . . . . 265895 . . Assy, Blower Mtg Flange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 44 . . . . . . . . . . . . . . 260558 . . Hose, 1.000 ID X 1.343 OD X 15.7500 Lg 100 PSI . . . . . . . . . . . . . . . . . . . 1
. . . 45 . . . . . . . . . . . . . . 260603 . . Ftg, Pipe Galv Elbow 45deg 1 NPT(F) X 1 NPT(F) . . . . . . . . . . . . . . . . . . 2
. . . 46 . . . . . . . . . . . . . . 260115 . . Hose, 1.000 ID X 1.343 OD X 24.000 Lg 100 PSI . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . 261072 . . Tubing, Pe Flame Ret 3/16 ID X 1/4 OD (Not Shown) . . . . . . . . . . . . . . . 4 Ft
+ When ordering a component originally displaying a precautionary label, the label should also be ordered.
* Recommended Spare Parts.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-260 545 Page 36
Hardware is common and
not available unless listed.
7
8
6
2
1
5
9
10
11
12
3
13
4
31
32
30
14
15
17
28
16
27
29
23
18
22
26
19
25
20
24
21
269 705-A
Figure 10-3. Control Box Assembly − Single-Phase (230 V)
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 10-3. Control Box Assembly − Single-Phase (230 V) (Figure 10-1, Item 6)
. . . 1 . . . . . . . . . . . . . . . 263919 . . Stop, Din Rail Low Profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 2 . . . . W1, W2 . . . 269728 . . Contactor, 9 A 3-Pole 24VDC No Aux Frame C . . . . . . . . . . . . . . . . . . . .
. . . 3 . . . . . PS1 . . . . 263939 . . Power Supply, Din Rail In:340−550 Vac Out:24VDC 5A . . . . . . . . . . . . .
. . . 4 . . . . . . . . . . . . . . . . . . . . . . . . . . Terminal (Includes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 210609 . . . . Strap, Grounding 16.62 In Long (Not Shown) . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 109398 . . + Screw, 250−20x1.50 Hex Hd−Pln Gr5 Pld Full Thread . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 601836 . . . . Nut, 250−20 .50hex .19h Brs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 5 . . . . . . . . . . . . . . . 264048 . . Tubing, PVC .125 Id X .250 Od Clear . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 6 . . . . . . . . . . . . . . . 249024 . . Fitting, Nylon Barbed Tee .156 X .125 X .156 . . . . . . . . . . . . . . . . . . . . . .
. . . 7 . . . . . . . . . . . . . . . 261072 . . Tubing, Pvc .187 Id X .250 Od Clear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 8 . . . . . . S3 . . . . . 263948 . . Switch, Pressure Differential 8 PSI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 9 . . . . . . . . . . . . . . . 258752 . . Contact Block, LED 24VDC N/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 10 . . . . . . . . . . . . . . . 260159 . . Contact Block N/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 11 . . . . . . . . . . . . . . . 263947 . . Gauge, Pressure Minihelic Differential 0−5 in W.C. . . . . . . . . . . . . . . . . .
. . . 12 . . . . S2/PL2 . . . 260162 . . Push Button, Flush Illuminated Blue . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 13 . . . . . . S1 . . . . . 159039 . . Switch, Rocker Spdt 15A 125VAC On−None−On Illum . . . . . . . . . . . . . .
. . . 14 . . . . . . . . . . . . . . . 268007 . . Assy, Control Box W/Auto Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nameplate (Order By Model And Serial No.) . . . . . . . . . . . . . . . . . . . . . . .
. . . 15 . . . . . . . . . . . . . . . 263938 . . Cover, Distribution Blk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 16 . . . TE1, TE2 . . 263924 . . Distribution Blk, 115 A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8
1
1
1
1
1
2
1ft
2
1ft
1
1
1
1
1
1
1
1
1
1
OM-260 545 Page 37
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 10-3. Control Box Assembly − Single-Phase (230 V) (Figure 10-1, Item 6) (Continued)
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
. . . F1, F2, F3 . .
. . . . . . T1 . . . . .
. . . . . PLC1 . . . .
...............
...............
...............
...............
. . . . . TE4 . . . .
. . . . . TE5 . . . .
...............
...............
...............
...............
. . . . . CB1 . . . .
. . . . . OL1 . . . .
...............
260157
263922
263942
268006
260965
260964
263921
254414
260776
254415
030170
139041
268002
269735
269729
265136
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
Fuse, Low Peak Class CC 3A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transformer, 460V/230−120V 50 VA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Controller, Micro 24VDC 12i/P X 6 Relay O/P . . . . . . . . . . . . . . . . . . . . . .
Rail, Din 35mm X 7.5mm X 6.000in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
End Section, Terminal Block Fem6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Jumper Bar, 5 Poles Bjmi6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Jumper Bar, 2 Poles Bjmi6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Terminal Block, M 4/6 Red . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Terminal Block, M 4/6 Grey . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rail, Din 35mm X 7.5mm X 3.500in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bushing, Snap-in Nyl .750 Id X 1.000 Mtg Hole . . . . . . . . . . . . . . . . . . . .
Bushing, Strain Relief .450/.709 Id X1.115 Mtg Hole . . . . . . . . . . . . . . . .
Rail, Din 35mm X 7.5mm X 5.000in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Circuit Breaker, Din Rail Mount 2P 25 A . . . . . . . . . . . . . . . . . . . . . . . . . . .
Relay, Overload 4−20 Fla Manual Reset Contact. Mtd. . . . . . . . . . . . . . .
Rail, Din 35mm X 7.5mm X 5.50 in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
1
1
1
3
2
1
6
5
1
1
2
1
1
1
1
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-260 545 Page 38
Hardware is common and
7
37
36
7
2
1
not available unless listed.
8
6
460 Volt model is shown.
5
10
5
9
3
575 Volt Model
11
4
12
13
38
35
OR
34
14
15
32
17
16
460 Volt Model
19
18
20
33
22
31
27
15
16
21
26
30
29
23
24
28
25
264 103-D
Figure 10-4. Control Box Assembly − Three-Phase (460 V and 575 V)
Quantity
Model
Item
No.
Dia.
Mkgs.
Part
No.
460
Volt
Description
575
Volt
Figure 10-4. Control Box Assembly − Three-Phase (460 V and 575 V) (Figure 10-1, Item 6)
. . . 1 . . . . . . . . . . . . . . 263919 . . Stop, Din Rail Low Profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 2 . W1, W2 . . . . 260155 . . Contactor, 9 A 3 Pole 24VDC No Aux . . . . . . . . . . . . . . . . . . . . . . .
. . . 3 . . . PS1 . . . . . . 263939 . . Power Supply, Din Rail In:340−550 Vac Out:24VDC 5A . . . . . . . .
. . . 4 . . . . . . . . . . . . . . . . . . . . . . . . Terminal (Includes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . 210609 . . . . Strap, Grounding 16.62 In Long (Not Shown) . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . 109398 . . + Screw, 250−20x1.50 Hex Hd−Pln Gr5 Pld Full Thread . . . . . . .
. . . . . . . . . . . . . . . . . . . . 601836 . . . . Nut, 250−20 .50hex .19h Brs . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 5 . . . . . . . . . . . . . . 264048 . . Tubing, PVC .125 Id X .250 Od Clear . . . . . . . . . . . . . . . . . . . . . . .
. . . 6 . . . . . . . . . . . . . . 249024 . . Fitting, Nylon Barbed Tee .156 X .125 X .156 . . . . . . . . . . . . . . . .
. . . 7 . . . . . . . . . . . . . . 261072 . . Tubing, Pvc .187 Id X .250 Od Clear . . . . . . . . . . . . . . . . . . . . . . . .
. . . 8 . . . . S3 . . . . . . 263948 . . Switch, Pressure Differential 8 PSI . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 9 . . . . . . . . . . . . . . 258752 . . Contact Block, LED 24VDC N/O . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 10 . . . . . . . . . . . . . . 260159 . . Contact Block N/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 11 . . . . . . . . . . . . . . 263947 . . Gauge, Pressure Minihelic Differential 0−5 in W.C. . . . . . . . . . . . .
. . . 12 . . S2/PL2 . . . . 260162 . . Push Button, Flush Illuminated Blue . . . . . . . . . . . . . . . . . . . . . . . .
. . . 13 . . . . S1 . . . . . . 159039 . . Switch, Rocker Spdt 15A 125VAC On−None−On Illum . . . . . . . .
. . . 14 . . . . . . . . . . . . . . 268007 . . Assy, Control Box W/Auto Phase . . . . . . . . . . . . . . . . . . . . . . . . . . .
10
2
1
1
1
1
2
1ft
2
1ft
1
1
1
1
1
1
1
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
10
2
1
1
1
1
2
1ft
2
1ft
1
1
1
1
1
1
1
OM-260 545 Page 39
Quantity
Model
Item
No.
Dia.
Mkgs.
Part
No.
Description
460
Volt
575
Volt
Figure 10-4. Control Box Assembly − Three-Phase (460V and 575V) (Figure 10-1, Item 6) (Continued)
..............................
. . . 15 . . . . . . . . . . . . . . 263938 . .
. . . 16 . TE1, TE2 . . . 263924 . .
. . . 17 PHASE MONITOR . 263940 . .
. . . . PHASE MONITOR . . 265112 . .
. . . 18 . . . . . . . . . . . . . . 263941 . .
. . . 19 F1, F2, F3 . . . 260157 . .
. . . . . . . . F1, F2 . . . . . 262736 . .
. . . 20 . . . . T1 . . . . . . 263922 . .
. . . . . . . . . . T1 . . . . . . 265217 . .
. . . 21 . . . . . . . . . . . . . . 267022 . .
. . . 22 . . PLC1 . . . . . 263942 . .
. . . 23 . . . . . . . . . . . . . . 266889 . .
. . . 24 . . . . . . . . . . . . . . 268006 . .
. . . 25 . . . . . . . . . . . . . . 260965 . .
. . . 26 . . . . . . . . . . . . . . 260964 . .
. . . 27 . . . . . . . . . . . . . . 263921 . .
. . . 28 . . . TE4 . . . . . . 254414 . .
. . . 29 . . . TE5 . . . . . . 260776 . .
. . . 30 . . . . . . . . . . . . . . 254415 . .
. . . 31 . . . . . . . . . . . . . . 030170 . .
. . . 32 . . . . . . . . . . . . . . 139041 . .
. . . 33 . . . . . . . . . . . . . . 268002 . .
. . . 34 . . . OL1 . . . . . . 265124 . .
. . . 35 . . . CB1 . . . . . . 263923 . .
. . . 36 . . . . . . . . . . . . . . 260158 . .
. . . 37 F4, F5, F6 . . . 265216 . .
. . . 38 . . . . . . . . . . . . . . 265136 . .
Nameplate (Order By Model And Serial No.) . . . . . . . . . . . . . . . . .
Cover, Distribution Blk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Distribution Blk, 115 A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Relay, Phase Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Relay, Phase Monitor 575V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Socket, Relay 8 Pin Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fuse, Low Peak Class CC 3A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fuse, Low Peak Class CC 2A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transformer, 460V/120V 50VA . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transformer, 575V/120V 50VA . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rail, Din 35mm X 7.5mm X 2.500in . . . . . . . . . . . . . . . . . . . . . . . . .
Controller, Micro 24VDC 12i/P X 6 Relay O/P . . . . . . . . . . . . . . . .
Controller, Micro 24vdc 2 O/P Add-on . . . . . . . . . . . . . . . . . . . . . . .
Rail, Din 35mm X 7.5mm X 6.000in . . . . . . . . . . . . . . . . . . . . . . . . .
End Section, Terminal Block Fem6 . . . . . . . . . . . . . . . . . . . . . . . . . .
Jumper Bar, 5 Poles Bjmi6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Jumper Bar, 2 Poles Bjmi6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Terminal Block, M 4/6 Red . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Terminal Block, M 4/6 Grey . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rail, Din 35mm X 7.5mm X 3.500in . . . . . . . . . . . . . . . . . . . . . . . . .
Bushing, Snap-in Nyl .750 Id X 1.000 Mtg Hole . . . . . . . . . . . . . .
Bushing, Strain Relief .450/.709 Id X1.115 Mtg Hole . . . . . . . . . . .
Rail, Din 35mm X 7.5mm X 5.000in . . . . . . . . . . . . . . . . . . . . . . . . .
Relay, Overload 3.2−16fla Manual Reset . . . . . . . . . . . . . . . . . . . .
Circuit Breaker, Din Rail Mount 3P 20 A . . . . . . . . . . . . . . . . . . . . .
Fuse Holder, Class Cc 30a W/Indicator . . . . . . . . . . . . . . . . . . . . . .
Fuse, Low Peak Class Cc 15a . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rail, Din 35mm X 7.5mm X 5.50 in . . . . . . . . . . . . . . . . . . . . . . . . .
1
2
2
1
0
1
3
0
1
0
1
1
1
1
3
2
1
6
5
1
1
2
1
1
1
0
0
1
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
1
2
2
0
1
1
1
2
0
1
1
1
1
1
3
2
1
6
5
1
1
2
1
1
0
1
3
1
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-260 545 Page 40
Extraction Arm
Figure 10-7
Figure 10-6
Figure 10-8
Figure 10-5
To maintain the factory original performance
of your equipment, use only Manufacturer’s
Suggested Replacement Parts. Model and
serial number required when ordering parts
from your local distributor.
Ref: 261 118-E
OM-260 545 Page 41
Hardware is common and
not available unless listed.
15
16
14
17
8
18
9
10
7
*11
10
* Also Shown
In Figure 10-6
13
12
19
21
12
*6
20
5
4
3
2
1
264 079-B
Figure 10-5. Extraction Arm Base Assembly
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 10-5. Extraction Arm Base Assembly
. . . 1 . . . . . . . . . . . . . +259777 . . Bracket, Lower Elbow Right 12.000 Collar . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 2 . . . . . . . . . . . . . . 261084 . . Label, Caution Pinch Point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 3 . . . . . . . . . . . . . . 259786 . . Spacer, Lower Elbow Rect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 4 . . . . . . . . . . . . . +259780 . . Bracket, Lower Elbow Left 12.000 Collar . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 5 . . . . . . . . . . . . . . 259909 . . Spacer, Mounting Gas Spring Wide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 6 . . . . . . . . . . . . . . 261570 . . Gas Spring, 550 Lb Lower (12 Ft Extraction Arm XD–12) . . . . . . . . . . . .
. . . 6 . . . . . . . . . . . . . . 261589 . . Gas Spring, 375 Lb Lower (10 Ft Extraction Arm XD–10) . . . . . . . . . . . .
. . . 7 . . . . . . . . . . . . . . 263833 . . Bolt, Crg Stl .375−16 X 3.500 Gr 2 Pld . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 8 . . . . . . . . . . . . . . 259793 . . Washer, Flat .560 X 1.380 X .109 Stl Pld . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 9 . . . . . . . . . . . . . . 263225 . . Plate, Clamping Lower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 10 . . . . . . . . . . . . . . 259792 . . Friction Disc, Lower Elbow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 11 . . . . . . . . . . . . . . 259776 . . Bracket, Lower Elbow 5.000 OD X 2.250 Wd . . . . . . . . . . . . . . . . . . . . . . .
. . . 12 . . . . . . . . . . . . . . 263226 . . Friction Disc, Lower Elbow Nyl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 13 . . . . . . . . . . . . . . 263861 . . Knob, T 3.500 Bar W/.375−16 Nut Plstc . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 14 . . . . . . . . . . . . . . 261208 . . Stand−Off, Tube 10−32 X 2.500 Lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 15 . . . . . . . . . . . . . . 259863 . . Stand−Off, Tube 10−32 X 1.500 Lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 16 . . . . . . . . . . . . . . 259829 . . Tube, Collar Inside . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 17 . . . . . . . . . . . . . . 259828 . . Plate, Base 12.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 18 . . . . . . . . . . . . . . 259821 . . Plate, Bearing 12.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 19 . . . . . . . . . . . . . . 259819 . . Collar, 12.00 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 20 . . . . . . . . . . . . . . 259822 . . Plate, Bearing 12.000 Ball Groove . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 21 . . . . . . . . . . . . . . 259785 . . Spacer, Lower Elbow Round . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
OM-260 545 Page 42
1
1
1
1
2
1
1
1
1
2
2
1
2
1
3
21
1
1
1
1
1
1
Hardware is common and
not available unless listed.
11
10
8
9
7
6
5
Also Shown
In Figure 10-7
12
4
3
2
14
*13
* Also Shown
In Figure 10-5
*1
264 083-B
Figure 10-6. Extraction Arm Tube Assembly
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 10-6. Extraction Arm Tube Assembly
. . . 1 . . . . . . . . . . . . . . 261570 . . Gas Spring, 550 Lb Lower (12 Ft Extraction Arm XD–12) . . . . . . . . . . . .
. . . 1 . . . . . . . . . . . . . . 261589 . . Gas Spring, 375 Lb Lower (10 Ft Extraction Arm XD–10) . . . . . . . . . . . .
. . . 2 . . . . . . . . . . . . . . 259781 . . Bracket, Mounting Gas Spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 3 . . . . . . . . . . . . . . 259908 . . Spacer, Mounting Gas Spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 4 . . . . . . . . . . . . . . 261587 . . Gas Spring (Upper) 275 Lb (12 Ft Extraction Arm XD–12) . . . . . . . . . . .
. . . 4 . . . . . . . . . . . . . . 261588 . . Gas Spring (Upper) 150 Lb (10 Ft Extraction Arm XD–10) . . . . . . . . . . .
. . . 5 . . . . . . . . . . . . . . 261084 . . Label, Caution Pinch Point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 6 . . . . . . . . . . . . . +259789 . . Beam, Lower Arm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 7 . . . . . . . . . . . . . . 259771 . . Bracket, Mounting Side Tube . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 8 . . . . . . . . . . . . . . 259863 . . Stand-Off, Tube 10−32 X 1.500 Lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 9 . . . . . . . . . . . . . . 261224 . . Nut, Cage .250−20 Speed Grip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 10 . . . . . . . . . . . . . . 259770 . . Bracket, Tube Spacer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 11 . . . . . . . . . . . . . . 259760 . . Tube, Inside 7.000 X 48.000 (12 Ft Extraction Arm XD–12) . . . . . . . . .
. . . 11 . . . . . . . . . . . . . . 259760 . . Tube, Inside 7.000 X 48.000 (10 Ft Extraction Arm XD–10) . . . . . . . . .
. . . 12 . . . . . . . . . . . . . . 256153 . . Tube, Lower 10.00 X 45.00 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 13 . . . . . . . . . . . . . . 259776 . . Bracket, Lower Elbow 5.000 OD X 2.250 Wd . . . . . . . . . . . . . . . . . . . . . . .
. . . 14 . . . . . . . . . . . . . . 261180 . . Tube, Flex 7.000 X 25.000 PVC (Base, Inner Tube) . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . 259766 . . Tube, Flex 10.000 X 28.000 PVC (Base, Outer Tube) . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . 261179 . . Tube, Flex 7.000 X 40.000 PVC (Middle Joint, Inner Tube) . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . 259765 . . Tube, Flex 10.000 X 43.000 PVC (Middle Joint, Outer Tube) . . . . . . . . . .
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
1
1
2
4
1
1
3
1
4
6
3
3
1
1
1
1
1
1
1
1
OM-260 545 Page 43
Hardware is common and
3
not available unless listed.
5
4
2
10
11
12
1
7
6
13
8
9
14
15
16
19
20
22
21
17
18
Also Shown
In Figure 10-6
264 109-B
Figure 10-7. Extraction Arm Middle Tube Assembly
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 10-7. Extraction Arm Middle Tube Assembly
... 1 ..............
... 1 ..............
... 2 ..............
... 3 ..............
... 4 ..............
... 5 ..............
... 6 ..............
... 7 ..............
... 8 ..............
... 9 ..............
. . . 10 . . . . . . . . . . . . . .
. . . 11 . . . . . . . . . . . . . .
. . . 12 . . . . . . . . . . . . . .
. . . 13 . . . . . . . . . . . . . .
. . . 14 . . . . . . . . . . . . . .
. . . 15 . . . . . . . . . . . . . .
. . . 16 . . . . . . . . . . . . . .
. . . 17 . . . . . . . . . . . . . .
. . . 18 . . . . . . . . . . . . . .
. . . 17 . . . . . . . . . . . . . .
. . . 19 . . . . . . . . . . . . . .
. . . 20 . . . . . . . . . . . . . .
. . . 21 . . . . . . . . . . . . . .
. . . 22 . . . . . . . . . . . . . .
....................
OM-260 545 Page 44
256151
256152
259760
259770
261224
259863
259907
256146
259775
259784
177707
265006
259791
259774
261233
261230
259783
259906
261587
261588
256141
259788
259771
261181
259767
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
Tube, Upper 10.00 X 45.00 (12 Ft Extraction Arm XD–12) . . . . . . . . . . .
Tube, Upper 10.00 X 21.00 (10 Ft. Extraction Arm XD–10) . . . . . . . . . .
Tube, Inside 7.000 X 48.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bracket, Tube Spacer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Nut, Cage .250−20 Speed Grip (12 Ft. Arm X1)−12 . . . . . . . . . . . . . . . . . .
Stand-Off, Tube 10−32 X 1.500 Lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Spacer, Linkage Gas Spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Friction Disc, Hood Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bracket, Upper Elbow 3.000 OD X 2.250 Wd . . . . . . . . . . . . . . . . . . . . . . .
Spacer, Upper Elbow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bolt, Crg Stl .312-18 X 3.500 Gr2 Pld . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Plate, Clamping Middle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Friction Disc, Upper Elbow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bracket, Upper Elbow 3.000 OD X 1.820 Wd . . . . . . . . . . . . . . . . . . . . . . .
Washer, Fender .438 ID X 1.375 OD X .051 Thk . . . . . . . . . . . . . . . . . . . . .
Knob, T 2.500 Bar W/.312−18 Nut Plstc . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bracket, Linkage Gas Spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Spacer, Rod Gas Spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gas Spring (Upper) 275 Lb (12 Ft Extraction Arm XD–12) . . . . . . . . . . .
Gas Spring (Upper) 150 Lb (10 Ft Extraction Arm XD–10) . . . . . . . . . . .
Rod, .375 OD X 250−20 Dbl End Fem Thd . . . . . . . . . . . . . . . . . . . . . . . . .
Beam, Upper Arm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bracket, Mtg Side Tube . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tube, Flex 7.000 X 17.000 PVC ( Hood Joint, Inner) . . . . . . . . . . . . . . . . .
Tube, Flex 10.000 X 20.000 PVC (Hood Joint, Outer) . . . . . . . . . . . . . . . .
1
1
1
3
2
6
4
2
1
1
1
2
2
1
2
1
4
2
1
1
1
1
4
1
1
Hardware is common and
not available unless listed.
12
11
13
10
9
8
6
14
7
5
15
4
16
17
3
2
1
18
19
264 108-A
Figure 10-8. Extraction Arm Hood Assembly
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 10-8. Extraction Arm Hood Assembly
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
+
1 . . . . . . . . . . . . . . 265907 . . Screen, Inlet Arm Hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2 . . . . . . . . . . . . . . 265909 . . Bracket, Inlet Screen Arm Hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3 . . . . . . . . . . . . . . 256134 . . Hood, Bell Mouth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
4 . . . . . . . . . . . . . . 259863 . . Stand-Off, Tube 10−32 X 1.500 LG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
5 . . . . . . . . . . . . . . 256136 . . Tube, Hood Inside . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
6 . . . . . . . . . . . . . . 261085 . . Label, Caution Air Discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
7 . . . . . . . . . . . . . +256135 . . Tube, Hood Outside . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
8 . . . . . . . . . . . . . . 256139 . . Bracket, Handle Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
9 . . . . . . . . . . . . . . 256138 . . Tube, Handle .50 OD X .40 ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
10 . . . . . . . . . . . . . . 264100 . . Bracket, Handle Stabilizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
11 . . . . . . . . . . . . . . 259904 . . Bracket, Hood Connection Clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
12 . . . . . . . . . . . . . . 256146 . . Friction Disc, Hood Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
13 . . . . . . . . . . . . . . 256144 . . Bracket, Hood Connection Middle 10.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
14 . . . . . . . . . . . . . . 256143 . . Bracket, Hood Connection End . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
15 . . . . . . . . . . . . . . 245188 . . Bolt, Crg Stl .312-18 X 1.000 Pld . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
16 . . . . . . . . . . . . . . 261233 . . Washer, Fender .438 X 1.375 OD X .051 Thk . . . . . . . . . . . . . . . . . . . . . . . 8
17 . . . . . . . . . . . . . . 261230 . . Knob, T 2.500 Bar W/.312−18 Nut Plstc . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
18 . . . . . . . . . . . . . . 145675 . . Nut, .312−18 .50 Hex .37 H Stl Pld Deformed Lkg Thrd . . . . . . . . . . . . . . . 2
19 . . . . . . . . . . . . . . 261692 . . Edge Trim, Screen Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 In.
When ordering a component originally displaying a precautionary label, the label should also be ordered.
OM-260 545 Page 45
Effective January 1, 2014
(Equipment with a serial number preface of ME or newer)
Warranty Questions?
Call
1-800-4-A-MILLER
for your local
Miller distributor.
Your distributor also gives
you ...
Service
You always get the fast,
reliable response you
need. Most replacement
parts can be in your
hands in 24 hours.
Support
Need fast answers to the
tough welding questions?
Contact your distributor.
The expertise of the
distributor and Miller is
there to help you, every
step of the way.
This limited warranty supersedes all previous Miller warranties and is exclusive with no other
guarantees or warranties expressed or implied.
LIMITED WARRANTY − Subject to the terms and conditions below, 5. 6 Months — Parts
Miller Electric Mfg. Co., Appleton, Wisconsin, warrants to its original
* Batteries
retail purchaser that new Miller equipment sold after the effective
* Bernard Guns (No Labor)
date of this limited warranty is free of defects in material and
* Tregaskiss Guns (No Labor)
workmanship at the time it is shipped by Miller. THIS WARRANTY IS
EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS 6. 90 Days — Parts
* Accessory (Kits)
OR IMPLIED, INCLUDING THE WARRANTIES OF
MERCHANTABILITY AND FITNESS.
* Canvas Covers
* Induction Heating Coils and Blankets, Cables, and
Within the warranty periods listed below, Miller will repair or replace
Non-Electronic Controls
any warranted parts or components that fail due to such defects in
* M-Guns
material or workmanship. Miller must be notified in writing within
* MIG Guns and Subarc (SAW) Guns
thirty (30) days of such defect or failure, at which time Miller will
* Remote Controls and RFCS-RJ45
provide instructions on the warranty claim procedures to be
* Replacement Parts (No labor)
followed.
* Roughneck Guns
Miller shall honor warranty claims on warranted equipment listed
* Spoolmate Spoolguns
below in the event of such a failure within the warranty time periods.
All warranty time periods start on the delivery date of the equipment
to the original end-user purchaser, and not to exceed twelve months
after the equipment is shipped to a North American distributor or
eighteen months after the equipment is shipped to an International
distributor.
1.
2.
3.
4.
5 Years Parts — 3 Years Labor
* Original Main Power Rectifiers Only to Include SCRs,
Diodes, and Discrete Rectifier Modules
3 Years — Parts and Labor
* Auto-Darkening Helmet Lenses (Except Classic
Series) (No Labor)
* Engine Driven Welding Generators
(NOTE: Engines are Warranted Separately by the
Engine Manufacturer.)
* Inverter Power Sources (Unless Otherwise Stated)
* Plasma Arc Cutting Power Sources
* Process Controllers
* Semi-Automatic and Automatic Wire Feeders
* Transformer/Rectifier Power Sources
2 Years — Parts and Labor
* Auto-Darkening Helmet Lenses − Classic Series Only
(No Labor)
* Fume Extractors − Capture 5, Filtair 400 and Industrial
Collector Series
1 Year — Parts and Labor Unless Specified
* Automatic Motion Devices
* CoolBelt and CoolBand Blower Unit (No Labor)
* External Monitoring Equipment and Sensors
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
Field Options
(NOTE: Field options are covered for the remaining
warranty period of the product they are installed in, or
for a minimum of one year — whichever is greater.)
RFCS Foot Controls (Except RFCS-RJ45)
Fume Extractors − Filtair 130, MWX and SWX Series
HF Units
ICE/XT Plasma Cutting Torches (No Labor)
Induction Heating Power Sources, Coolers
(NOTE: Digital Recorders are Warranted Separately
by the Manufacturer.)
LiveArc Welding Performance Management System
Load Banks
Motor Driven Guns (except Spoolmate Spoolguns)
PAPR Blower Unit (No Labor)
Positioners and Controllers
Racks
Running Gear/Trailers
Spot Welders
Subarc Wire Drive Assemblies
Water Coolant Systems
TIG Torches (No Labor)
Wireless Remote Foot/Hand Controls and Receivers
Work Stations/Weld Tables (No Labor)
Miller’s True Blue® Limited Warranty shall not apply to:
1.
2.
3.
Consumable components; such as contact tips,
cutting nozzles, contactors, brushes, relays, work
station table tops and welding curtains, or parts that
fail due to normal wear. (Exception: brushes and
relays are covered on all engine-driven products.)
Items furnished by Miller, but manufactured by others,
such as engines or trade accessories. These items are
covered by the manufacturer’s warranty, if any.
Equipment that has been modified by any party other than
Miller, or equipment that has been improperly installed,
improperly operated or misused based upon industry
standards, or equipment which has not had reasonable
and necessary maintenance, or equipment which has
been used for operation outside of the specifications for
the equipment.
MILLER PRODUCTS ARE INTENDED FOR PURCHASE AND
USE BY COMMERCIAL/INDUSTRIAL USERS AND PERSONS
TRAINED AND EXPERIENCED IN THE USE AND
MAINTENANCE OF WELDING EQUIPMENT.
In the event of a warranty claim covered by this warranty, the
exclusive remedies shall be, at Miller’s option: (1) repair; or (2)
replacement; or, where authorized in writing by Miller in appropriate
cases, (3) the reasonable cost of repair or replacement at an
authorized Miller service station; or (4) payment of or credit for the
purchase price (less reasonable depreciation based upon actual
use) upon return of the goods at customer’s risk and expense.
Miller’s option of repair or replacement will be F.O.B., Factory at
Appleton, Wisconsin, or F.O.B. at a Miller authorized service facility
as determined by Miller. Therefore no compensation or
reimbursement for transportation costs of any kind will be allowed.
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR
DIRECT,
INDIRECT,
SPECIAL,
INCIDENTAL
OR
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF PROFIT),
WHETHER BASED ON CONTRACT, TORT OR ANY OTHER
LEGAL THEORY.
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND ANY
IMPLIED WARRANTY, GUARANTY OR REPRESENTATION AS
TO PERFORMANCE, AND ANY REMEDY FOR BREACH OF
CONTRACT TORT OR ANY OTHER LEGAL THEORY WHICH,
BUT FOR THIS PROVISION, MIGHT ARISE BY IMPLICATION,
OPERATION OF LAW, CUSTOM OF TRADE OR COURSE OF
DEALING, INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR PARTICULAR
PURPOSE, WITH RESPECT TO ANY AND ALL EQUIPMENT
FURNISHED BY MILLER IS EXCLUDED AND DISCLAIMED BY
MILLER.
Some states in the U.S.A. do not allow limitations of how long an
implied warranty lasts, or the exclusion of incidental, indirect,
special or consequential damages, so the above limitation or
exclusion may not apply to you. This warranty provides specific
legal rights, and other rights may be available, but may vary from
state to state.
In Canada, legislation in some provinces provides for certain
additional warranties or remedies other than as stated herein, and to
the extent that they may not be waived, the limitations and
exclusions set out above may not apply. This Limited Warranty
provides specific legal rights, and other rights may be available, but
may vary from province to province.
miller_warr 2014-04-14
Owner’s Record
Please complete and retain with your personal records.
Model Name
Serial/Style Number
Purchase Date
(Date which equipment was delivered to original customer.)
Distributor
Address
City
State
Zip
For Service
Contact a DISTRIBUTOR or SERVICE AGENCY near you.
Always provide Model Name and Serial/Style Number.
Contact your Distributor for:
Welding Supplies and Consumables
Options and Accessories
Personal Safety Equipment
Service and Repair
Miller Electric Mfg. Co.
An Illinois Tool Works Company
1635 West Spencer Street
Appleton, WI 54914 USA
Replacement Parts
Training (Schools, Videos, Books)
Technical Manuals (Servicing Information
and Parts)
Circuit Diagrams
For International Locations Visit
www.MillerWelds.com
Welding Process Handbooks
To locate a Distributor or Service Agency visit
www.millerwelds.com or call 1-800-4-A-Miller
Contact the Delivering Carrier to:
File a claim for loss or damage during
shipment.
For assistance in filing or settling claims, contact
your distributor and/or equipment manufacturer’s
Transportation Department.
ORIGINAL INSTRUCTIONS − PRINTED IN USA
International Headquarters−USA
USA Phone: 920-735-4505 Auto-Attended
USA & Canada FAX: 920-735-4134
International FAX: 920-735-4125
© 2014 Miller Electric Mfg. Co.
2014−01
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement