Miller | MH140578L | Owner Manual | Miller FLOWMAX User manual

Miller FLOWMAX User manual
OM-248626G
2017-03
Processes
TIG (GTAW) Welding
MIG (GMAW) Welding
Description
Flowmax
CE And Non-CE
File: TIG (GTAW)
TABLE OF CONTENTS
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Cooling Equipment Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4. California Proposition 65 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1. Symboles utilisés . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2. Dangers liés aux équipements de refroidissement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance . . . . .
2-4. Proposition californienne 65 Avertissements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-5. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 − DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1. Additional Safety Symbols And Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2. Miscellaneous Symbols And Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 4 − SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-1. Serial Number And Rating Label Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3. Coolant Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-4. Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 5 − INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-1. GTAW Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2. GMAW Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 − MAINTENANCE & TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-2. Coolant Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-3. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-4. Electrical Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 7 − PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARRANTY
1
1
1
1
2
2
3
3
3
3
4
4
5
5
6
7
7
7
7
7
8
8
9
10
10
10
11
11
12
DECLARATION OF CONFORMITY
for European Community (CE marked) products.
MILLER Electric Mfg. Co., 1635 Spencer Street, Appleton, WI 54914 U.S.A. declares that the
product(s) identified in this declaration conform to the essential requirements and provisions of
the stated Council Directive(s) and Standard(s).
Product/Apparatus Identification:
Stock Number
043008001
Product
Flowmax 230 VAC
Council Directives:
• 2014/35/EU Low voltage
• 2014/30/EU Electromagnetic compatibility
• 2011/65/EU Restriction of the use of certain hazardous substances in electrical and electronic equipment
Standards:
• IEC 60974-2:2013 Arc welding equipment – Part 2: Liquid cooling systems
• IEC 60974-10:2014 Arc welding equipment – Part 10: Electromagnetic compatibility requirements
Signatory:
March 24, 2017
_____________________________________
___________________________________________
David A. Werba
Date of Declaration
MANAGER, PRODUCT DESIGN COMPLIANCE
245863E
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING
coolers 2016-08
7
Protect yourself and others from injury — read, follow, and save these important safety precautions and operating instructions.
1-1. Symbol Usage
DANGER! − Indicates a hazardous situation which, if
not avoided, will result in death or serious injury. The
possible hazards are shown in the adjoining symbols
or explained in the text.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury. The possible
hazards are shown in the adjoining symbols or explained in the text.
NOTICE − Indicates statements not related to personal injury.
. Indicates special instructions.
This group of symbols means Warning! Watch Out! ELECTRIC
SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult symbols and related instructions below for necessary actions to avoid the
hazards.
1-2. Cooling Equipment Hazards
The symbols shown below are used throughout this manual
to call attention to and identify possible hazards. When you
see the symbol, watch out, and follow the related instructions
to avoid the hazard. The safety information given below is
only a summary of the more complete safety information
found in the Safety Standards listed in Section 1-5. Read and
follow all Safety Standards.
Only qualified persons should install, operate, maintain, and
repair this unit.
During operation, keep everybody, especially children, away.
HOT PARTS can burn.
D Do not touch hot parts bare handed.
D Allow cooling period before working on
equipment.
D To handle hot parts, use proper tools and/or wear heavy, insulated welding gloves and clothing to prevent burns.
FLYING METAL or DIRT can injure eyes.
D Wear approved safety glasses with side
shields even under your welding helmet.
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shocks
or severe burns. The input power circuit and machine
internal circuits are also live when power is on.
Incorrectly installed or improperly grounded equipment is a hazard.
D Do not touch live electrical parts.
D Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
D Properly install, ground, and operate this equipment according to
its Owner’s Manual and national, state, and local codes.
D Always verify the supply ground − check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
grounded receptacle outlet.
D Keep cords dry, free of oil and grease, and protected from hot metal
and sparks.
D Frequently inspect input power cord and ground conductor for
damage or bare wiring – replace immediately if damaged – bare
wiring can kill.
D Turn off all equipment when not in use.
D Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
D Keep all panels and covers securely in place.
1-3. Additional Symbols For Installation, Operation, And Maintenance
FALLING EQUIPMENT can injure.
D Use equipment of adequate capacity to lift and
support unit.
D If using lift forks to move unit, be sure forks are
long enough to extend beyond opposite side of
unit.
D Keep equipment (cables and cords) away from moving vehicles
when working from an aerial location.
D Follow the guidelines in the Applications Manual for the Revised
NIOSH Lifting Equation (Publication No. 94−110) when manually lifting heavy parts or equipment.
OVERUSE can cause OVERHEATING
READ INSTRUCTIONS.
D Read and follow all labels and the Owner’s
Manual carefully before installing, operating, or
servicing unit. Read the safety information at
the beginning of the manual and in each
section.
D Use only genuine replacement parts from the manufacturer.
D Perform installation, maintenance, and service according to the
Owner’s Manuals, industry standards, and national, state, and
local codes.
D Read and understand the Safety Data Sheets (SDSs) and the
manufacturer’s instructions for adhesives, coatings, cleaners,
consumables, coolants, degreasers, fluxes, and metals.
D Allow cooling period; follow rated duty cycle.
D Do not block or filter airflow to unit.
OM-248626 Page 1
STEAM AND HOT COOLANT can burn.
Hose may rupture if coolant overheats.
D
D Visually inspect condition of hoses before each
use. Do not use damaged hoses.
Allow cooling period before working on equipment.
HIGH PRESSURE FLUIDS can injure or kill.
MOVING PARTS can injure.
D Keep away from moving parts such as fans.
D Keep all doors, panels, covers, and guards
closed and securely in place.
D Have only qualified persons remove doors, panels, covers, or
guards for maintenance and troubleshooting as necessary.
D Reinstall doors, panels, covers, or guards when maintenance is
finished and before reconnecting input power.
D Coolant can be under high pressure.
D Release pressure before working on cooler.
D If ANY fluid is injected into the skin or body seek medical help
immediately.
1-4. California Proposition 65 Warnings
Welding or cutting equipment produces fumes or gases
which contain chemicals known to the State of California to
cause birth defects and, in some cases, cancer. (California
Health & Safety Code Section 25249.5 et seq.)
This product contains chemicals, including lead, known to
the state of California to cause cancer, birth defects, or other
reproductive harm. Wash hands after use.
This product contains or produces a chemical known to the
state of California to cause cancer or birth defects (or other
reproductive harm). (California Health & Safety Code Section
25249.5 et seq.)
1-5. Principal Safety Standards
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
is available as a free download from the American Welding Society at
http://www.aws.org or purchased from Global Engineering Documents
(phone: 1-877-413-5184, website: www.global.ihs.com).
Safe Practices for the Preparation of Containers and Piping for Welding
and Cutting, American Welding Society Standard AWS F4.1, from Global Engineering Documents (phone: 1-877-413-5184, website:
www.global.ihs.com).
Safe Practices for Welding and Cutting Containers that have Held Combustibles, American Welding Society Standard AWS A6.0, from Global
Engineering Documents (phone: 1-877-413-5184,
website: www.global.ihs.com).
National Electrical Code, NFPA Standard 70, from National Fire Protection Association, Quincy, MA 02269 (phone: 1-800-344-3555, website:
www.nfpa.org and www. sparky.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 14501 George Carter Way, Suite
103, Chantilly, VA 20151 (phone: 703-788-2700, website:
www.cganet.com).
OM-248626 Page 2
Safety in Welding, Cutting, and Allied Processes, CSA Standard
W117.2, from Canadian Standards Association, Standards Sales, 5060
Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5NS
(phone: 800-463-6727, website: www.csagroup.org).
Safe Practice For Occupational And Educational Eye And Face Protection, ANSI Standard Z87.1, from American National Standards Institute,
25 West 43rd Street, New York, NY 10036 (phone: 212-642-4900, website: www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, from National Fire Protection Association,
Quincy, MA 02269 (phone: 1-800-344-3555, website: www.nfpa.org).
OSHA, Occupational Safety and Health Standards for General Industry, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,
and Part 1926, Subpart J, from U.S. Government Printing Office, Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954
(phone: 1-866-512-1800) (there are 10 OSHA Regional Offices—
phone for Region 5, Chicago, is 312-353-2220, website:
www.osha.gov).
Applications Manual for the Revised NIOSH Lifting Equation, The National Institute for Occupational Safety and Health (NIOSH), 1600
Clifton Rd, Atlanta, GA 30329-4027 (phone: 1-800-232-4636, website:
www.cdc.gov/NIOSH).
SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION
Cooler 2016−08_fre
Pour écarter les risques de blessure pour vous−même et pour autrui — lire, appliquer et ranger en lieu sûr ces consignes relatives
aux précautions de sécurité et au mode opératoire.
2-1. Symboles utilisés
DANGER! − Indique une situation dangereuse qui si on
l’évite pas peut donner la mort ou des blessures graves.
Les dangers possibles sont montrés par les symboles
joints ou sont expliqués dans le texte.
Indique une situation dangereuse qui si on l’évite pas
peut donner la mort ou des blessures graves. Les
dangers possibles sont montrés par les symboles
joints ou sont expliqués dans le texte.
AVIS − Indique des déclarations pas en relation avec des blessures
personnelles.
. Indique des instructions spécifiques.
Ce groupe de symboles veut dire Avertissement! Attention! DANGER
DE CHOC ELECTRIQUE, PIECES EN MOUVEMENT, et PIECES
CHAUDES. Consulter les symboles et les instructions ci-dessous y
afférant pour les actions nécessaires afin d’éviter le danger.
2-2. Dangers liés aux équipements de refroidissement
Les symboles représentés ci-dessous sont utilisés dans ce
manuel pour attirer l’attention et identifier les dangers possibles.
En présence de l’un de ces symboles, prendre garde et suivre
les instructions afférentes pour éviter tout risque. Les
instructions en matière de sécurité indiquées ci-dessous ne
constituent qu’un sommaire des instructions de sécurité plus
complètes fournies dans les normes de sécurité énumérées
dans la Section 2-5. Lire et observer toutes les normes de
sécurité.
Seul un personnel qualifié est autorisé à installer, faire
fonctionner, entretenir et réparer cet appareil.
Pendant le fonctionnement, maintenir à distance toutes les
personnes, notamment les enfants de l’appareil.
LES PIÈCES CHAUDES peuvent
provoquer des brûlures.
D Ne pas toucher à mains nues les parties
chaudes.
D Prévoir une période de refroidissement avant de
travailler à l’équipement.
D Ne pas toucher aux pièces chaudes, utiliser les outils recommandés et porter des gants de soudage et des vêtements épais pour
éviter les brûlures.
DES PIECES DE METAL ou DES
SALETES peuvent provoquer des
blessures dans les yeux.
D Porter des lunettes de sécurité avec écrans
latéraux ou un écran facial.
UNE DÉCHARGE ÉLECTRIQUE peut
entraîner la mort.
Le contact d’organes électriques sous tension peut
provoquer des accidents mortels ou des brûlures
graves. Le circuit d’alimentation et les circuits
internes de la machine sont également sous tension
lorsque l’alimentation est sur Marche. Un équipement installé ou mis
à la terre de manière incorrecte ou impropre constitue un danger.
D Ne pas toucher aux pièces électriques sous tension.
D Couper l’alimentation ou arrêter le moteur avant de procéder
à l’installation, à la réparation ou à l’entretien de l’appareil.
Déverrouiller l’alimentation selon la norme OSHA 29 CFR
1910.147 (voir normes de sécurité).
D Installez, mettez à la terre et utilisez correctement cet équipement
conformément à son Manuel d’Utilisation et aux réglementations
nationales, gouvernementales et locales.
D Toujours vérifier la terre du cordon d’alimentation. Vérifier et
s’assurer que le fil de terre du cordon d’alimentation est bien
raccordé à la borne de terre du sectionneur ou que la fiche du
cordon est raccordée à une prise correctement mise à la terre.
D Les câbles doivent être exempts d’humidité, d’huile et de graisse;
protégez−les contre les étincelles et les pièces métalliques
chaudes.
D Vérifier fréquemment le cordon d’alimentation afin de s’assurer
qu’il n’est pas altéré ou à nu, le remplacer immédiatement s’il l’est.
Un fil à nu peut entraîner la mort.
D L’équipement doit être hors tension lorsqu’il n’est pas utilisé.
D N’utiliser qu’un matériel en bon état. Réparer ou remplacer
sur-le-champ les pièces endommagées. Entretenir l’appareil
conformément à ce manuel.
D S’assurer que tous les panneaux et couvercles sont correctement
en place.
2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance
LA CHUTE DE L’ÉQUIPEMENT peut
provoquer des blessures.
D Utiliser un équipement de levage de capacité
suffisante pour lever l’appareil.
D En utilisant des fourches de levage pour
déplacer l’unité, s’assurer que les fourches
sont suffisamment longues pour dépasser du
côté opposé de l’appareil.
D Tenir l’équipement (câbles et cordons) à distance des véhicules
mobiles lors de toute opération en hauteur.
D Suivre les consignes du Manuel des applications pour l’équation
de levage NIOSH révisée (Publication Nº94–110) lors du levage
manuelle de pièces ou équipements lourds.
L’EMPLOI
EXCESSIF
peut
SURCHAUFFER L’ÉQUIPEMENT.
D Prévoir une période de refroidissement ;
respecter le cycle opératoire nominal.
D Ne pas obstruer les passages d’air du poste.
OM-248626 Page 3
LA VAPEUR ET LE LIQUIDE DE
REFROIDISSEMENT CHAUD peuvent
provoquer des brûlures.
LIRE LES INSTRUCTIONS.
D Lire et appliquer les instructions sur les
étiquettes et le Mode d’emploi avant
l’installation, l’utilisation ou l’entretien de
l’appareil. Lire les informations de sécurité au
début du manuel et dans chaque section.
D N’utiliser que les pièces de rechange recommandées par le
constructeur.
D Effectuer l’installation, l’entretien et toute intervention selon les
manuels d’utilisateurs, les normes nationales, provinciales et de
l’industrie, ainsi que les codes municipaux.
D Lire et comprendre les fiches de données de sécurité et les
instructions du fabricant concernant les adhésifs, les revêtements,
les nettoyants, les consommables, les produits de refroidissement,
les dégraisseurs, les flux et les métaux.
Un tuyau peut se rompre lorsque le liquide de
refroidissement surchauffe.
D
D Vérifiez visuellement l’état des tuyaux avant
chaque utilisation. N’utilisez pas de tuyaux
endommagés.
Laissez refroidir avant d’intervenir sur l’équipement.
LES LIQUIDES SOUS HAUTE PRESSION
peuvent provoquer des blessures ou la
mort.
Les PIÈCES MOBILES peuvent
causer des blessures.
D S’abstenir de toucher des organes mobiles tels
que des ventilateurs.
D Maintenir fermés et verrouillés les portes,
panneaux, recouvrements et dispositifs de
protection.
D Lorsque cela est nécessaire pour des travaux d’entretien et de
dépannage, faire retirer les portes, panneaux, recouvrements
ou dispositifs de protection uniquement par du personnel
qualifié.
D Remettre les portes, panneaux, recouvrements ou dispositifs de
protection quand l’entretien est terminé et avant de rebrancher
l’alimentation électrique.
D Liquide de
pression.
refroidissement
sous
haute
D Libérez la pression avant d’intervenir sur le
refroidisseur.
D En cas d’injection d’un liquide QUELCONQUE dans la peau ou
le corps, consultez immédiatement un médecin.
2-4. Proposition californienne 65 Avertissements
Les équipements de soudage et de coupage produisent des
fumées et des gaz qui contiennent des produits chimiques
dont l’État de Californie reconnaît qu’ils provoquent des
malformations congénitales et, dans certains cas, des
cancers. (Code de santé et de sécurité de Californie, chapitre
25249.5 et suivants)
Ce produit contient ou forme un produit chimique reconnu
par l’état de Californie de provoquer le cancer ou
malformations de naissance (ou autre problèmes
reproductifs. (Code de santé et de sécurité de Californie,
chapitre 25249.5 et suivants).
Ce produit contient des produits chimiques, notamment du
plomb, dont l’État de Californie reconnaît qu’ils provoquent
des cancers, des malformations congénitales ou d’autres
problèmes de procréation. Se laver les mains après
utilisation.
2-5. Principales normes de sécurité
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
is available as a free download from the American Welding Society at
http://www.aws.org or purchased from Global Engineering Documents
(phone: 1-877-413-5184, website: www.global.ihs.com).
Safe Practices for the Preparation of Containers and Piping for Welding
and Cutting, American Welding Society Standard AWS F4.1, from
Global Engineering Documents (phone: 1-877-413-5184, website:
www.global.ihs.com).
Safe Practices for Welding and Cutting Containers that have Held
Combustibles, American Welding Society Standard AWS A6.0, from
Global Engineering Documents (phone: 1-877-413-5184,
website: www.global.ihs.com).
National Electrical Code, NFPA Standard 70, from National Fire
Protection Association, Quincy, MA 02269 (phone: 1-800-344-3555,
website: www.nfpa.org and www. sparky.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 14501 George Carter Way, Suite
103, Chantilly, VA 20151 (phone: 703-788-2700, website:
www.cganet.com).
OM-248626 Page 4
Safety in Welding, Cutting, and Allied Processes, CSA Standard
W117.2, from Canadian Standards Association, Standards Sales, 5060
Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5NS
(phone: 800-463-6727, website: www.csagroup.org).
Safe Practice For Occupational And Educational Eye And Face
Protection, ANSI Standard Z87.1, from American National Standards
Institute, 25 West 43rd Street, New York, NY 10036 (phone:
212-642-4900, website: www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, from National Fire Protection Association,
Quincy, MA 02269 (phone: 1-800-344-3555, website: www.nfpa.org).
OSHA, Occupational Safety and Health Standards for General
Industry, Title 29, Code of Federal Regulations (CFR), Part 1910,
Subpart Q, and Part 1926, Subpart J, from U.S. Government Printing
Office, Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA
15250-7954 (phone: 1-866-512-1800) (there are 10 OSHA Regional
Offices—phone for Region 5, Chicago, is 312-353-2220, website:
www.osha.gov).
Applications Manual for the Revised NIOSH Lifting Equation, The
National Institute for Occupational Safety and Health (NIOSH), 1600
Clifton Rd, Atlanta, GA 30329-4027 (phone: 1-800-232-4636, website:
www.cdc.gov/NIOSH).
SECTION 3 − DEFINITIONS
3-1. Additional Safety Symbols And Definitions
. Some symbols are found only on CE products.
Warning! Watch Out! There are possible hazards as shown by the symbols.
Safe1 2012−05
Disconnect input plug or power before working on machine.
Safe5 2012−05
Do not discard product (where applicable) with general waste.
Reuse or recycle Waste Electrical and Electronic Equipment (WEEE) by disposing at a designated collection
facility.
Contact your local recycling office or your local distributor for further information.
Safe37 2012−05
Do not remove or paint over (cover) the label.
Safe20 2012−05
Plugged filter or hoses can cause overheating to the power source
and torch.
Safe50 2012−05
Use coolant suggested by the manufacturer.
XXXXX
Safe52 2012−05
100 h. Std.
Every 100 hours, check and clean filter and check condition of hoses.
Safe51 2012−05
Recycle.
Safe103 2012−09
OM-248626 Page 5
3-2. Miscellaneous Symbols And Definitions
A
V
Voltage Input
Volts
Water (Coolant)
Output
Single Phase
Primary Current
Cooling
Protective Earth
(Ground)
On
Alternating Current
Water (Coolant)
Input
IP
Degree Of
Protection
Off
Notes
OM-248626 Page 6
Hz
Amperes
I1
U1
Primary Voltage
Circulating Unit
With Coolant
Pump
Line Connection
I1max
P1
pmax
Hertz
Rated Maximum
Supply Current
Rated Cooling
Power
Rated Maximum
Pressure
SECTION 4 − SPECIFICATIONS
4-1. Serial Number And Rating Label Location
The serial number and rating information for this product is located on the back panel. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on cover of this manual.
4-2. Specifications
. The correction factor on the cooling power at an ambient temperature of 1045F (405C) is 0.625.
Recirculating Coolant System For Water-Cooled GTAW Torches, GMAW Guns, And Induction Heaters
Use With Guns/Torches Rated Up To 600 Amperes
Coolant Tank Capacity
3 gal (11.4 L)
Maximum Cooling Power
4.1 kW at 1.25 qt/min at 77°F (14,000 BTU/hr at 1.2 L/min at 25°C)
Dimensions (Length x Width x Height)
23 x 12 x 13.25 in. (584 x 305 x 337 mm)
Weight
39 lb (18 kg)
Input Voltage
115 or 230 VC, Single Phase, 50 or 60 Hz
Input Amperage
115 Volt Model: 5.9 Amperes, 50/60 Hertz
230 Volt CE Model: 3 Amperes, 50/60 Hertz
4-3. Coolant Specifications
Do not use conductive coolant.
Application
Coolant
GTAW Or Where High Frequency Current Is Used
Low Conductivity Coolant 043810*
Distilled Or Deionized Water Okay Above 32°F (0°C)
GMAW Or Where High Frequency Current Is Not Used
Low Conductivity Coolant 043810*
Aluminum Protecting Coolant 043809*
Distilled Or Deionized Water Okay Above 32°F (0°C)
Aluminum Protecting Coolant 043809*
Where Coolant Contacts Aluminum Parts
*Coolants 043810 and 043809 protect to -37°F (-38°C) and resist algae growth.
NOTICE − Use of any coolant other than those listed in the table voids the warranty on any parts that come in contact with the coolant (pump, radiator,
etc.).
4-4. Environmental Specifications
A. IP Rating
IP Rating
IP23
This equipment is designed for outdoor use.
IP23 2017−02
B. Information On Electromagnetic Compatibility (EMC)
!
This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low−
voltage supply system. There can be potential difficulties in ensuring electromagnetic compatibility in those locations, due to conducted as well as radiated disturbances.
This equipment complies with IEC 61000-3-11 and IEC 61000-3-12.
ce-emc 4 2014-07
C. Temperature Specifications
Operating Temperature Range
Storage/Transportation Temperature Range
14 to 104 °F (-10 to 40°C)
−4 to 131°F (−20 to 55°C)
Temp1_2016- 08
OM-248626 Page 7
SECTION 5 − INSTALLATION
5-1. GTAW Connections
2
1
3
6
7
4
5
Tools Needed:
5/8 in.
801190-E
!
!
1
Do not move or operate unit where
it could tip.
230 volt AC coolers only: Replace
power cord plug if supplied plug
does not match receptacle. Have a
qualified person install correct 230
volt AC plug according to national
and local codes.
Lift -Eye
If placing cooling unit on welding power
source, slots are provided in bottom of unit
so it fits over lift-eye.
To prevent overheating, make sure cooling
unit is positioned so airflow is not restricted.
OM-248626 Page 8
2
115 Or 230 Volt AC Grounded Receptacle (Depending On Model)
4
Coolant In Hose
Fittings have 5/8-18 left-hand threads.
Connect hoses with proper fittings as
shown.
An individual circuit capable of carrying 15
amperes and protected by fuses or circuit
breakers is recommended. Recommended fuse or circuit breaker size is 15
amperes. For 230 volt models, an individual branch circuit capable of carrying 10 amperes and protected by fuses or circuit
breakers is recommended. Recommended fuse or circuit breaker size is 10
amperes.
Customer supplied for use with some welding power sources, or use proper connector supplied with welding power source.
NOTICE − If welding power source has a
water valve, do not connect hoses to water
valve. Connect hoses as shown.
7
3
Coolant Out Hose
5
6
TIG Block
Coolant Tank Cap
Use table in Section 4-3 to select proper
coolant, and fill tank. Maintain coolant level
at approximately 1 in. (25 mm) below top of
filler neck.
Power Switch
Operation:
Turn power switch On.
5-2. GMAW Connections
1
2
3
5
6
4
Tools Needed:
5/8 in.
801191-E
!
Do not move or operate unit where
it could tip.
2
!
230 volt AC coolers only: Replace
power cord plug if supplied plug
does not match receptacle. Have a
qualified person install correct 230
volt AC plug according to national
and local codes.
An individual circuit capable of carrying 15
amperes and protected by fuses or circuit
breakers is recommended. Recommended fuse or circuit breaker size is 15
amperes. For 230 volt models, an individual branch circuit capable of carrying 10 amperes and protected by fuses or circuit
breakers is recommended. Recommended fuse or circuit breaker size is 10
amperes.
1
Lift -Eye
If placing cooling unit on welding power
source, slots are provided in bottom of unit
so it fits over lift-eye.
To prevent overheating, make sure cooling
unit is positioned so airflow is not restricted.
115 Or 230 Volt AC Grounded Receptacle (Depending On Model)
NOTICE − If welding power source has a
water valve, do not connect hoses to water
valve. Connect hoses as shown.
3
Coolant Out Hose
4
Coolant In Hose
Fittings have 5/8-18 left-hand threads.
Connect hoses with proper fittings as
shown.
5
Coolant Tank Cap
Use table in Section 4-3 to select proper
coolant, and fill tank. Maintain coolant level
at approximately 1 in. (25 mm) below top of
filler neck.
6
Power Switch
Operation:
Turn power switch On.
OM-248626 Page 9
SECTION 6 − MAINTENANCE & TROUBLESHOOTING
6-1. Routine Maintenance
!
n = Check
Z = Change
~ = Clean
* To be done by Factory Authorized Service Agent
Every
3
Months
~Coolant Filter, durning heavy
service, clean more frequently.
Every
6
Months
l = Replace
~ Blow out heat exchanger fins.
nCheck coolant level. Top off with
distilled or deionized water if necessary.
Change
Coolant (If
Using Water)
nlHoses
Every
12
Months
Δ = Repair
Disconnect power
before maintaining.
nl Labels
ZReplace coolant.
Change
Coolant (If
Using 043 809
or 043 810
Coolant)
ZReplace coolant.
6-2. Coolant Maintenance
1
!
Disconnect cooler plug from
welding power source receptacle
before maintaining.
!
Dispose of used coolant according to national, state, and local
codes. Do not pour down drain.
1
Coolant Filter
Unscrew housing to clean filter and
housing.
Changing Coolant
Drain coolant by tipping unit forward. Fill
with clean water and run for 10 minutes.
Drain and refill.
NOTICE − If replacing hoses, use hoses
compatible with ethylene glycol, such as
Buna-n, Neoprene, or Hypalon.
Oxy-acetylene hoses are not compatible with any product containing ethylene
glycol.
Tools Needed:
3/8 in.
801189-D / 803557-A
OM-248626 Page 10
6-3. Troubleshooting
Trouble
Coolant system does not work.
Remedy
Be sure input power cord is plugged in to energized receptacle.
Check line fuses or circuit breaker, and replace or reset if necessary.
Motor overheated. Unit starts running when motor has cooled.
Have Factory Authorized Service Agent check Power switch S1 and motor (Mot).
Decreased or no coolant flow.
Add coolant.
Check for clogged hoses or coolant filter. Clean filter or clean / replace hoses if necessary.
Disconnect pump, and check for sheared coupling. Replace coupling if necessary.
6-4. Electrical Diagram
Input power
135796-D
Figure 6-1. Circuit Diagram For 115/230 Volt Models
OM-248626 Page 11
SECTION 7 − PARTS LIST
14
11
2
10
15
1
12
23 6
5
24
23
12
8
21 25
20
26
4
13
16
22
7
9
21
17
12
22
18
31
28
12
27
30
*included with item 25
29
*
805 487-D
Figure 7-1. Complete Assembly
OM-248626 Page 12
Item
No.
....
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
1
2
4
5
6
7
8
9
10
10
11
12
13
14
15
16
16
17
18
20
21
22
23
24
25
27
28
29
30
31
Dia.
Mkgs.
Part
No.
Flowmax-115
Flowmax-230 CE
Description
Quantity
Figure 7-1. Complete Assembly
. . . . . . . . . . . +166562 . . . . . Wrapper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 253514 . . . . . Label, Warning General Precautionary Static (Eng/Fr) . . . . . . . . . . . . . . .
. . . . . . . . . . . . 255480 . . . . . Pump Coolant W/Fittings, (Includes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . 5523 . . . . . . . Fitting, Hose Brs Barbed M 3/8tbg X 3/8 NPT . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 134795 . . . . . . . Coupler, Drive Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 196990 . . . . . Fitting, Hose Brs Barbed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 149332 . . . . . Clamp, Hose .405 − .485 Clip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 196991 . . . . . Hose, Nprn Brd No 1 X .250ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . MOT . . . 173264 . . . . . Motor, 1/4hp 230VAC 50/60HZ 1425/1725RPM (230V CE Model) . . . . .
. . . MOT . . . 173263 . . . . . Motor, 1/4hp 115VAC 50/60hz 1425/1725RPM (115V Model) . . . . . . . . . .
. . . . . . . . . . . . 166570 . . . . . Blade, Fan 9.000 5wg 38deg .500 Bore CW (Setscrew Included) . . . . . .
. . . . . . . . . . . . 231400 . . . . . Hose, Rubber Braided .375 ID X .650 OD X 17.000 . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 094263 . . . . . Clamp, 1-Ear Type Nom Dim .718 X .276 Wide . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 192454 . . . . . Panel, Rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 139042 . . . . . Bushing, Strain Relief .270/.480 ID X .804 Mtg Hol . . . . . . . . . . . . . . . . . .
. . PLG1 . . . 192457 . . . . . Cable, Power 10ft 16ga (115V Model) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . PLG1 . . . 192458 . . . . . Cable, Pwr 11ft (230V CE Model) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 196515 . . . . . Radiator, Heat Exchanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 269910 . . . . . Tank Coolant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 166608 . . . . . Cap, Tank Screw-On W/Vent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 255481 . . . . . Hose, Pick-up Coolant W/Clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 236084 . . . . . Hose, Rubber Braided .375 ID X .650 OD X 10.500 . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 255485 . . . . . Hose, Rubber Braided .375 ID X .650 OD X 3.750 . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 166560 . . . . . Ring, Ring Ext .500 Shaft Grv X .042thk . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 166564 . . . . . Filter, In-Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . S1 . . . . 177396 . . . . . Switch, Rocker DPST 15A 250VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 177399 . . . . . Panel, Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . GB0002 . . . . . Plug, Knock-Out 1-11/16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . Nameplate, (Order By Model And Serial Number) . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 166571 . . . . . Fitting, Coolant Barbed 3/8tbg 5/8-18 Female . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
2
1
1
1
1
1
1
1
2
8
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
2
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
BE SURE TO PROVIDE MODEL AND SERIAL NUMBER WHEN ORDERING REPLACEMENT PARTS.
OM-248626 Page 13
Notes
TM-222 Page 14
Gold Star Series
Effective January 1, 2017
(Equipment with a serial number preface of MH or newer)
Warranty Questions?
Call
1-800-4-A-MILLER
for your local
Miller distributor.
Your distributor also gives
you ...
Service
You always get the fast,
reliable response you
need. Most replacement
parts can be in your
hands in 24 hours.
Support
Need fast answers to the
tough welding questions?
Contact your distributor.
The expertise of the
distributor and Miller is
there to help you, every
step of the way.
This limited warranty supersedes all previous Miller warranties and is exclusive with no other
guarantees or warranties expressed or implied.
LIMITED WARRANTY − Subject to the terms and conditions below, 5. 6 Months — Parts
Miller Electric Mfg. Co., Appleton, Wisconsin, warrants to its original
* Batteries
retail purchaser that new Miller equipment sold after the effective date of
6.
90
Days — Parts
this limited warranty is free of defects in material and workmanship at
* Accessory (Kits)
the time it is shipped by Miller. THIS WARRANTY IS EXPRESSLY IN
LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,
* Canvas Covers
INCLUDING THE WARRANTIES OF MERCHANTABILITY AND
* Induction Heating Coils and Blankets, Cables, and
FITNESS.
Non-Electronic Controls
Within the warranty periods listed below, Miller will repair or replace any
* M-Guns
warranted parts or components that fail due to such defects in material
* MIG Guns, Subarc (SAW) Torches, and External
or workmanship. Miller must be notified in writing within thirty (30) days
Cladding Heads
of such defect or failure, at which time Miller will provide instructions on
*
Remote
Controls and RFCS-RJ45
the warranty claim procedures to be followed. If notification is submitted
* Replacement Parts (No labor)
as an online warranty claim, the claim must include a detailed
* Spoolmate Spoolguns
description of the fault and the troubleshooting steps taken to identify
failed components and the cause of their failure.
Miller shall honor warranty claims on warranted equipment listed below
in the event of such a failure within the warranty time periods. All
warranty time periods start on the delivery date of the equipment to the
original end-user purchaser, and not to exceed twelve months after the
equipment is shipped to a North American distributor or eighteen
months after the equipment is shipped to an International distributor.
1.
2.
3.
4.
5 Years Parts — 3 Years Labor
* Original Main Power Rectifiers Only to Include SCRs,
Diodes, and Discrete Rectifier Modules
3 Years — Parts and Labor
* Auto-Darkening Helmet Lenses (Except Classic
Series) (No Labor)
* Engine Driven Welder/Generators
(NOTE: Engines are Warranted Separately by the
Engine Manufacturer.)
* Inverter Power Sources (Unless Otherwise Stated)
* Plasma Arc Cutting Power Sources
* Process Controllers
* Semi-Automatic and Automatic Wire Feeders
* Transformer/Rectifier Power Sources
2 Years — Parts and Labor
* Auto-Darkening Helmet Lenses − Classic Series Only
(No Labor)
* Fume Extractors − Capture 5, Filtair 400 and Industrial
Collector Series
1 Year — Parts and Labor Unless Specified
* AugmentedArc and LiveArc Welding Systems
* Automatic Motion Devices
* Bernard BTB Air-Cooled MIG Guns (No Labor)
* CoolBelt and CoolBand Blower Unit (No Labor)
* Desiccant Air Dryer System
* External Monitoring Equipment and Sensors
* Field Options
(NOTE: Field options are covered for the remaining
warranty period of the product they are installed in,
or for a minimum of one year — whichever is
greater.)
* RFCS Foot Controls (Except RFCS-RJ45)
* Fume Extractors − Filtair 130, MWX and SWX Series
* HF Units
* ICE/XT Plasma Cutting Torches (No Labor)
* Induction Heating Power Sources, Coolers
(NOTE: Digital Recorders are Warranted
Separately by the Manufacturer.)
* Load Banks
* Motor-Driven Guns (except Spoolmate Spoolguns)
* PAPR Blower Unit (No Labor)
* Positioners and Controllers
* Racks
* Running Gear/Trailers
* Spot Welders
* Subarc Wire Drive Assemblies
* TIG Torches (No Labor)
* Tregaskiss Guns (No Labor)
* Water Cooling Systems
* Wireless Remote Foot/Hand Controls and Receivers
* Work Stations/Weld Tables (No Labor)
Miller’s True Blue® Limited Warranty shall not apply to:
1.
2.
3.
Consumable components; such as contact tips,
cutting nozzles, contactors, brushes, relays, work
station table tops and welding curtains, or parts that
fail due to normal wear. (Exception: brushes and
relays are covered on all engine-driven products.)
Items furnished by Miller, but manufactured by others,
such as engines or trade accessories. These items are
covered by the manufacturer’s warranty, if any.
Equipment that has been modified by any party other than
Miller, or equipment that has been improperly installed,
improperly operated or misused based upon industry
standards, or equipment which has not had reasonable
and necessary maintenance, or equipment which has
been used for operation outside of the specifications for
the equipment.
MILLER PRODUCTS ARE INTENDED FOR PURCHASE AND
USE BY COMMERCIAL/INDUSTRIAL USERS AND PERSONS
TRAINED AND EXPERIENCED IN THE USE AND
MAINTENANCE OF WELDING EQUIPMENT.
In the event of a warranty claim covered by this warranty, the
exclusive remedies shall be, at Miller’s option: (1) repair; or (2)
replacement; or, where authorized in writing by Miller in appropriate
cases, (3) the reasonable cost of repair or replacement at an
authorized Miller service station; or (4) payment of or credit for the
purchase price (less reasonable depreciation based upon actual
use) upon return of the goods at customer’s risk and expense.
Miller’s option of repair or replacement will be F.O.B., Factory at
Appleton, Wisconsin, or F.O.B. at a Miller authorized service facility
as determined by Miller. Therefore no compensation or
reimbursement for transportation costs of any kind will be allowed.
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR
DIRECT,
INDIRECT,
SPECIAL,
INCIDENTAL
OR
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF PROFIT),
WHETHER BASED ON CONTRACT, TORT OR ANY OTHER
LEGAL THEORY.
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND ANY
IMPLIED WARRANTY, GUARANTY OR REPRESENTATION AS
TO PERFORMANCE, AND ANY REMEDY FOR BREACH OF
CONTRACT TORT OR ANY OTHER LEGAL THEORY WHICH,
BUT FOR THIS PROVISION, MIGHT ARISE BY IMPLICATION,
OPERATION OF LAW, CUSTOM OF TRADE OR COURSE OF
DEALING, INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR PARTICULAR
PURPOSE, WITH RESPECT TO ANY AND ALL EQUIPMENT
FURNISHED BY MILLER IS EXCLUDED AND DISCLAIMED BY
MILLER.
Some states in the U.S.A. do not allow limitations of how long an
implied warranty lasts, or the exclusion of incidental, indirect,
special or consequential damages, so the above limitation or
exclusion may not apply to you. This warranty provides specific
legal rights, and other rights may be available, but may vary from
state to state.
In Canada, legislation in some provinces provides for certain
additional warranties or remedies other than as stated herein, and
to the extent that they may not be waived, the limitations and
exclusions set out above may not apply. This Limited Warranty
provides specific legal rights, and other rights may be available, but
may vary from province to province.
miller_warr 2017-01
Owner’s Record
Please complete and retain with your personal records.
Model Name
Serial/Style Number
Purchase Date
(Date which equipment was delivered to original customer.)
Distributor
Address
City
State
Zip
For Service
Contact a DISTRIBUTOR or SERVICE AGENCY near you.
Always provide Model Name and Serial/Style Number.
Contact your Distributor for:
Welding Supplies and Consumables
Options and Accessories
Personal Safety Equipment
Service and Repair
Miller Electric Mfg. Co.
An Illinois Tool Works Company
1635 West Spencer Street
Appleton, WI 54914 USA
Replacement Parts
Training (Schools, Videos, Books)
Technical Manuals (Servicing Information
and Parts)
Circuit Diagrams
For International Locations Visit
www.MillerWelds.com
Welding Process Handbooks
To locate a Distributor or Service Agency visit
www.millerwelds.com or call 1-800-4-A-Miller
Contact the Delivering Carrier to:
File a claim for loss or damage during
shipment.
For assistance in filing or settling claims, contact
your distributor and/or equipment manufacturer’s
Transportation Department.
ORIGINAL INSTRUCTIONS − PRINTED IN USA
International Headquarters−USA
USA Phone: 920-735-4505 Auto-Attended
USA & Canada FAX: 920-735-4134
International FAX: 920-735-4125
© 2017 Miller Electric Mfg. Co.
2017−01
Was this manual useful for you? yes no