Miller I-22 CE Owner’s Manual
PDF
Download
Document
Advertisement
Advertisement
OM-186 895N September 2002 Processes MIG (GMAW) Welding Flux Cored (FCAW) Welding Description Wire Feeder I-22 & I-24 Visit our website at www.MillerWelds.com From Miller to You Thank you and congratulations on choosing Miller. Now you can get the job done and get it done right. We know you don’t have time to do it any other way. That’s why when Niels Miller first started building arc welders in 1929, he made sure his products offered long-lasting value and superior quality. Like you, his customers couldn’t afford anything less. Miller products had to be more than the best they could be. They had to be the best you could buy. Today, the people that build and sell Miller products continue the tradition. They’re just as committed to providing equipment and service that meets the high standards of quality and value established in 1929. This Owner’s Manual is designed to help you get the most out of your Miller products. Please take time to read the Safety precautions. They will help you protect yourself against potential hazards on the worksite. We’ve made installation and operation quick and easy. With Miller you can count on years of reliable service with proper maintenance. And if for some reason the unit needs repair, there’s a Troubleshooting section that will help you figure out what the problem is. The Miller is the first welding parts list will then help you to decide the equipment manufacturer in exact part you may need to fix the problem. the U.S.A. to be registered to the ISO 9001:2000 Quality Warranty and service information for your System Standard. particular model are also provided. Working as hard as you do – every power source from Miller is backed by the most hassle-free warranty in the business. Miller offers a Technical Manual which provides more detailed service and parts information for your unit. To obtain a Technical Manual, contact your local distributor. Your distributor can also supply you with Welding Process Manuals such as SMAW, GTAW, GMAW, and GMAW-P. Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog orindividual catalog sheets. To locate your nearest distributor or service agency call 1-800-4-A-Miller, or visit us at www.MillerWelds.com on the web. TABLE OF CONTENTS WARNING This product, when used for welding or cutting, produces fumes or gases which contain chemicals known to the State of California to cause birth defects and, in some cases, cancer. (California Health & Safety Code Section 25249.5 et seq.) OM-186 895 SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . . . 1-4. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 1 – CONSIGNES DE SECURITE – LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . . 1-1. Signification des symboles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2. Dangers relatifs au soudage à l’arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5. Information sur les champs électromagnétiques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 2 – DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1. Warning Label Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2. Rating Label For CE Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3. Symbols And Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 3 – INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2. Site Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3. Gun Recommendation Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4. Equipment Connection Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5. 14-Pin Receptacle, Shielding Gas And Optional Volt Sense Lead . . . . . . . . . . . . . . . . . . . . . . 3-6. 14-Pin Receptacle Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7. Connecting Welding Gun And Weld Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8. Optional Meter Circuit Board Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9. Motor Start/Burnback Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10.Installing Wire Guide And Drive Roll . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11.Installing And Threading Welding Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 4 – OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1. Front Panel Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2. Optional Side Panel Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 5 – MAINTENANCE & TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2. Overload Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 6 – ELECTRICAL DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 7 – PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OPTIONS AND ACCESSORIES WARRANTY 1 1 1 3 3 4 5 5 5 7 8 8 9 9 10 10 11 11 11 12 12 12 13 13 14 15 16 17 18 18 19 19 19 20 20 22 23 Declaration of Conformity for European Community (CE) Products NOTE This information is provided for units with CE certification (see rating label on unit). Miller Electric Mfg. Co. Manufacturer’s Name: 1635 W. Spencer Street Appleton, WI 54914 USA Manufacturer’s Address: Declares that the product: I-22A And I-24A conforms to the following Directives and Standards: Directives Low Voltage Directive: 73/23/EEC Electromagnetic Compatibility (EMC) Directive: 89/336/EEC Machinery Directives: 89/392/EEC, 91/368/EEC, 93/C 133/04, 93/68/EEC Standards Arc Welding Equipment Part I: Welding Power Sources: IEC 60974-1 (September 1998 – Second Edition) Arc Welding Equipment: Wirefeed Systems: IEC 974-5 (September 1997 – Draft Revision) Degrees of Protection Provided By Enclosures (IP Code): IEC 529 (November 1989 – First Edition) Insulation Coordination For Equipment With Low-Voltage Systems: Part I: Principles, Requirements and Tests: IEC 664-1 (October 1992 – First Edition) Electromagnetic Compatibility, (EMC): EN 50199 (August 1995) European Contact: Telephone: Fax: dec_con1 1/96 Mr. Danilo Fedolfi, Managing Director MILLER Europe S.r.l. Via Privata Iseo 20098 San Giuliano Milanese, Italy 39(02)98290-1 39(02)98281-552 SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING som _nd_4/98 1-1. Symbol Usage Means Warning! Watch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. Y Marks a special safety message. . Means “Note”; not safety related. This group of symbols means Warning! Watch Out! possible ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult symbols and related instructions below for necessary actions to avoid the hazards. 1-2. Arc Welding Hazards Y The symbols shown below are used throughout this manual to call attention to and identify possible hazards. When you see the symbol, watch out, and follow the related instructions to avoid the hazard. The safety information given below is only a summary of the more complete safety information found in the Safety Standards listed in Section 1-4. Read and follow all Safety Standards. D If earth grounding of the workpiece is required, ground it directly with a separate cable. Y Only qualified persons should install, operate, maintain, and repair this unit. D Wear a safety harness if working above floor level. D Keep all panels and covers securely in place. Y During operation, keep everybody, especially children, away. D Clamp work cable with good metal-to-metal contact to workpiece or worktable as near the weld as practical. ELECTRIC SHOCK can kill. Touching live electrical parts can cause fatal shocks or severe burns. The electrode and work circuit is electrically live whenever the output is on. The input power circuit and machine internal circuits are also live when power is on. In semiautomatic or automatic wire welding, the wire, wire reel, drive roll housing, and all metal parts touching the welding wire are electrically live. Incorrectly installed or improperly grounded equipment is a hazard. D Do not touch electrode if you are in contact with the work, ground, or another electrode from a different machine. D Use only well-maintained equipment. Repair or replace damaged parts at once. Maintain unit according to manual. D Insulate work clamp when not connected to workpiece to prevent contact with any metal object. D Do not connect more than one electrode or work cable to any single weld output terminal. SIGNIFICANT DC VOLTAGE exists after removal of input power on inverters. D Turn Off inverter, disconnect input power, and discharge input capacitors according to instructions in Maintenance Section before touching any parts. D Do not touch live electrical parts. D Wear dry, hole-free insulating gloves and body protection. D Insulate yourself from work and ground using dry insulating mats or covers big enough to prevent any physical contact with the work or ground. D Do not use AC output in damp areas, if movement is confined, or if there is a danger of falling. D Use AC output ONLY if required for the welding process. D If AC output is required, use remote output control if present on unit. D Disconnect input power or stop engine before installing or servicing this equipment. Lockout/tagout input power according to OSHA 29 CFR 1910.147 (see Safety Standards). D Properly install and ground this equipment according to its Owner’s Manual and national, state, and local codes. D Keep your head out of the fumes. Do not breathe the fumes. D Always verify the supply ground – check and be sure that input power cord ground wire is properly connected to ground terminal in disconnect box or that cord plug is connected to a properly grounded receptacle outlet. D When making input connections, attach proper grounding conductor first – double-check connections. D Frequently inspect input power cord for damage or bare wiring – replace cord immediately if damaged – bare wiring can kill. D Turn off all equipment when not in use. D Do not use worn, damaged, undersized, or poorly spliced cables. D Do not weld in locations near degreasing, cleaning, or spraying operations. The heat and rays of the arc can react with vapors to form highly toxic and irritating gases. D Do not drape cables over your body. FUMES AND GASES can be hazardous. Welding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health. D If inside, ventilate the area and/or use exhaust at the arc to remove welding fumes and gases. D If ventilation is poor, use an approved air-supplied respirator. D Read the Material Safety Data Sheets (MSDSs) and the manufacturer’s instructions for metals, consumables, coatings, cleaners, and degreasers. D Work in a confined space only if it is well ventilated, or while wearing an air-supplied respirator. Always have a trained watchperson nearby. Welding fumes and gases can displace air and lower the oxygen level causing injury or death. Be sure the breathing air is safe. D Do not weld on coated metals, such as galvanized, lead, or cadmium plated steel, unless the coating is removed from the weld area, the area is well ventilated, and if necessary, while wearing an air-supplied respirator. The coatings and any metals containing these elements can give off toxic fumes if welded. OM-186 895 Page 1 ARC RAYS can burn eyes and skin. Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld. D Wear a welding helmet fitted with a proper shade of filter to protect your face and eyes when welding or watching (see ANSI Z49.1 and Z87.1 listed in Safety Standards). D Wear approved safety glasses with side shields under your helmet. D Use protective screens or barriers to protect others from flash and glare; warn others not to watch the arc. D Wear protective clothing made from durable, flame-resistant material (leather and wool) and foot protection. BUILDUP OF GAS can injure or kill. D Shut off shielding gas supply when not in use. D Always ventilate confined spaces or use approved air-supplied respirator. HOT PARTS can cause severe burns. D Do not touch hot parts bare handed. D Allow cooling period before working on gun or torch. MAGNETIC FIELDS can affect pacemakers. WELDING can cause fire or explosion. Welding on closed containers, such as tanks, drums, or pipes, can cause them to blow up. Sparks can fly off from the welding arc. The flying sparks, hot workpiece, and hot equipment can cause fires and burns. Accidental contact of electrode to metal objects can cause sparks, explosion, overheating, or fire. Check and be sure the area is safe before doing any welding. D Protect yourself and others from flying sparks and hot metal. D Do not weld where flying sparks can strike flammable material. D Remove all flammables within 35 ft (10.7 m) of the welding arc. If this is not possible, tightly cover them with approved covers. D Be alert that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas. D Watch for fire, and keep a fire extinguisher nearby. D Be aware that welding on a ceiling, floor, bulkhead, or partition can cause fire on the hidden side. D Do not weld on closed containers such as tanks, drums, or pipes, unless they are properly prepared according to AWS F4.1 (see Safety Standards). D Connect work cable to the work as close to the welding area as practical to prevent welding current from traveling long, possibly unknown paths and causing electric shock and fire hazards. D Do not use welder to thaw frozen pipes. D Remove stick electrode from holder or cut off welding wire at contact tip when not in use. D Wear oil-free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes, and a cap. D Remove any combustibles, such as a butane lighter or matches, from your person before doing any welding. FLYING METAL can injure eyes. D Welding, chipping, wire brushing, and grinding cause sparks and flying metal. As welds cool, they can throw off slag. D Wear approved safety glasses with side shields even under your welding helmet. OM-186 895 Page 2 D Pacemaker wearers keep away. D Wearers should consult their doctor before going near arc welding, gouging, or spot welding operations. NOISE can damage hearing. Noise from some processes or equipment can damage hearing. D Wear approved ear protection if noise level is high. CYLINDERS can explode if damaged. Shielding gas cylinders contain gas under high pressure. If damaged, a cylinder can explode. Since gas cylinders are normally part of the welding process, be sure to treat them carefully. D Protect compressed gas cylinders from excessive heat, mechanical shocks, slag, open flames, sparks, and arcs. D Install cylinders in an upright position by securing to a stationary support or cylinder rack to prevent falling or tipping. D Keep cylinders away from any welding or other electrical circuits. D Never drape a welding torch over a gas cylinder. D Never allow a welding electrode to touch any cylinder. D Never weld on a pressurized cylinder – explosion will result. D Use only correct shielding gas cylinders, regulators, hoses, and fittings designed for the specific application; maintain them and associated parts in good condition. D Turn face away from valve outlet when opening cylinder valve. D Keep protective cap in place over valve except when cylinder is in use or connected for use. D Read and follow instructions on compressed gas cylinders, associated equipment, and CGA publication P-1 listed in Safety Standards. 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. MOVING PARTS can cause injury. D Do not install or place unit on, over, or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring – be sure power supply system is properly sized, rated, and protected to handle this unit. D Keep away from moving parts such as fans. D Keep all doors, panels, covers, and guards closed and securely in place. FALLING UNIT can cause injury. H.F. RADIATION can cause interference. D Use lifting eye to lift unit only, NOT running gear, gas cylinders, or any other accessories. D Use equipment of adequate capacity to lift and support unit. D If using lift forks to move unit, be sure forks are long enough to extend beyond opposite side of unit. D OVERUSE can cause OVERHEATING D D Allow cooling period; follow rated duty cycle. D Reduce current or reduce duty cycle before starting to weld again. D Do not block or filter airflow to unit. D D D High-frequency (H.F.) can interfere with radio navigation, safety services, computers, and communications equipment. D Have only qualified persons familiar with electronic equipment perform this installation. The user is responsible for having a qualified electrician promptly correct any interference problem resulting from the installation. If notified by the FCC about interference, stop using the equipment at once. Have the installation regularly checked and maintained. Keep high-frequency source doors and panels tightly shut, keep spark gaps at correct setting, and use grounding and shielding to minimize the possibility of interference. STATIC (ESD) can damage PC boards. D Put on grounded wrist strap BEFORE handling boards or parts. D Use proper static-proof bags and boxes to store, move, or ship PC boards. ARC WELDING can cause interference. MOVING PARTS can cause injury. D Keep away from moving parts. D Keep away from pinch points such as drive rolls. D D WELDING WIRE can cause injury. D D Do not press gun trigger until instructed to do so. D Do not point gun toward any part of the body, other people, or any metal when threading welding wire. D D Electromagnetic energy can interfere with sensitive electronic equipment such as computers and computer-driven equipment such as robots. D Be sure all equipment in the welding area is electromagnetically compatible. To reduce possible interference, keep weld cables as short as possible, close together, and down low, such as on the floor. Locate welding operation 100 meters from any sensitive electronic equipment. Be sure this welding machine is installed and grounded according to this manual. If interference still occurs, the user must take extra measures such as moving the welding machine, using shielded cables, using line filters, or shielding the work area. 1-4. Principal Safety Standards Safety in Welding and Cutting, ANSI Standard Z49.1, from American Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126 Safety and Health Standards, OSHA 29 CFR 1910, from Superintendent of Documents, U.S. Government Printing Office, Washington, D.C. 20402. Recommended Safe Practices for the Preparation for Welding and Cutting of Containers That Have Held Hazardous Substances, American Welding Society Standard AWS F4.1, from American Welding Society, 550 N.W. LeJeune Rd, Miami, FL 33126 National Electrical Code, NFPA Standard 70, from National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, from Compressed Gas Association, 1235 Jefferson Davis Highway, Suite 501, Arlington, VA 22202. Code for Safety in Welding and Cutting, CSA Standard W117.2, from Canadian Standards Association, Standards Sales, 178 Rexdale Boulevard, Rexdale, Ontario, Canada M9W 1R3. Safe Practices For Occupation And Educational Eye And Face Protection, ANSI Standard Z87.1, from American National Standards Institute, 1430 Broadway, New York, NY 10018. Cutting And Welding Processes, NFPA Standard 51B, from National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. OM-186 895 Page 3 1-5. EMF Information Considerations About Welding And The Effects Of Low Frequency Electric And Magnetic Fields Welding current, as it flows through welding cables, will cause electromagnetic fields. There has been and still is some concern about such fields. However, after examining more than 500 studies spanning 17 years of research, a special blue ribbon committee of the National Research Council concluded that: “The body of evidence, in the committee’s judgment, has not demonstrated that exposure to powerfrequency electric and magnetic fields is a human-health hazard.” However, studies are still going forth and evidence continues to be examined. Until the final conclusions of the research are reached, you may wish to minimize your exposure to electromagnetic fields when welding or cutting. To reduce magnetic fields in the workplace, use the following procedures: OM-186 895 Page 4 1. Keep cables close together by twisting or taping them. 2. Arrange cables to one side and away from the operator. 3. Do not coil or drape cables around your body. 4. Keep welding power source and cables as far away from operator as practical. 5. Connect work clamp to workpiece as close to the weld as possible. About Pacemakers: Pacemaker wearers consult your doctor first. If cleared by your doctor, then following the above procedures is recommended. SECTION 1 – CONSIGNES DE SECURITE – LIRE AVANT UTILISATION som _nd_fre 4/98 1-1. Signification des symboles Signifie Mise en garde ! Soyez vigilant ! Cette procédure présente des risques de danger ! Ceux-ci sont identifiés par des symboles adjacents aux directives. Y Identifie un message de sécurité particulier. . Signifie NOTA ; n’est pas relatif à la sécurité. Ce groupe de symboles signifie Mise en garde ! Soyez vigilant ! Il y a des risques de danger reliés aux CHOCS ÉLECTRIQUES, aux PIÈCES EN MOUVEMENT et aux PIÈCES CHAUDES. Reportez-vous aux symboles et aux directives ci-dessous afin de connaître les mesures à prendre pour éviter tout danger. 1-2. Dangers relatifs au soudage à l’arc Y Les symboles présentés ci-après sont utilisés tout au long du présent manuel pour attirer votre attention et identifier les risques de danger. Lorsque vous voyez un symbole, soyez vigilant et suivez les directives mentionnées afin d’éviter tout danger. Les consignes de sécurité présentées ci-après ne font que résumer l’information contenue dans les normes de sécurité énumérées à la section 1-4. Veuillez lire et respecter toutes ces normes de sécurité. Y L’installation, l’utilisation, l’entretien et les réparations ne doivent être confiés qu’à des personnes qualifiées. Y Au cours de l’utilisation, tenir toute personne à l’écart et plus particulièrement les enfants. D N’utiliser qu’un matériel en bon état. Réparer ou remplacer sur-lechamp les pièces endommagées. Entretenir l’appareil conformément à ce manuel. D Porter un harnais de sécurité quand on travaille en hauteur. D Maintenir solidement en place tous les panneaux et capots. D Fixer le câble de retour de façon à obtenir un bon contact métal-métal avec la pièce à souder ou la table de travail, le plus près possible de la soudure. D Isoler la pince de masse quand pas mis à la pièce pour éviter le contact avec tout objet métallique. UN CHOC ÉLECTRIQUE peut tuer. Un simple contact avec des pièces électriques peut provoquer une électrocution ou des blessures graves. L’électrode et le circuit de soudage sont sous tension dès que l’appareil est sur ON. Le circuit d’entrée et les circuits internes de l’appareil sont également sous tension à ce moment-là. En soudage semi-automatique ou automatique, le fil, le dévidoir, le logement des galets d’entraînement et les pièces métalliques en contact avec le fil de soudage sont sous tension. Des matériels mal installés ou mal mis à la terre présentent un danger. Il y a DU COURANT CONTINU IMPORTANT dans les convertisseurs après la suppression de l’alimentation électrique. D Arrêter les convertisseurs, débrancher le courant électrique, et décharger les condensateurs d’alimentation selon les instructions indiquées dans la partie entretien avant de toucher les pièces. D Ne jamais toucher les pièces électriques sous tension. D Porter des gants et des vêtements de protection secs ne comportant pas de trous. D S’isoler de la pièce et de la terre au moyen de tapis ou d’autres moyens isolants suffisamment grands pour empêcher le contact physique éventuel avec la pièce ou la terre. D D D Ne pas se servir de source électrique àcourant électrique dans les zones humides, dans les endroits confinés ou là où on risque de tomber. Se servir d’une source électrique àcourant électrique UNIQUEMENT si le procédé de soudage le demande. Si l’utilisation d’une source électrique àcourant électrique s’avère nécessaire, se servir de la fonction de télécommande si l’appareil en est équipé. D Couper l’alimentation ou arrêter le moteur avant de procéder à l’installation, à la réparation ou à l’entretien de l’appareil. Déverrouiller l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de sécurité). D Installer et mettre à la terre correctement cet appareil conformément à son manuel d’utilisation et aux codes nationaux, provinciaux et municipaux. D Toujours vérifier la terre du cordon d’alimentation – Vérifier et s’assurer que le fil de terre du cordon d’alimentation est bien raccordé à la borne de terre du sectionneur ou que la fiche du cordon est raccordée à une prise correctement mise à la terre. D En effectuant les raccordements d’entrée fixer d’abord le conducteur de mise à la terre approprié et contre-vérifier les connexions. D Vérifier fréquemment le cordon d’alimentation pour voir s’il n’est pas endommagé ou dénudé – remplacer le cordon immédiatement s’il est endommagé – un câble dénudé peut provoquer une électrocution. D Mettre l’appareil hors tension quand on ne l’utilise pas. D Ne pas utiliser des câbles usés, endommagés, de grosseur insuffisante ou mal épissés. D Ne pas enrouler les câbles autour du corps. D Si la pièce soudée doit être mise à la terre, le faire directement avec un câble distinct. D Ne pas toucher l’électrode quand on est en contact avec la pièce, la terre ou une électrode provenant d’une autre machine. LES FUMÉES ET LES GAZ peuvent être dangereux. Le soudage génère des fumées et des gaz. Leur inhalation peut être dangereux pour votre santé. D D D D D D D Eloigner votre tête des fumées. Ne pas respirer les fumées. A l’intérieur, ventiler la zone et/ou utiliser un échappement au niveau de l’arc pour l’évacuation des fumées et des gaz de soudage. Si la ventilation est insuffisante, utiliser un respirateur à alimentation d’air homologué. Lire les spécifications de sécurité des matériaux (MSDSs) et les instructions du fabricant concernant les métaux, les consommables, les revêtements, les nettoyants et les dégraisseurs. Travailler dans un espace fermé seulement s’il est bien ventilé ou en portant un respirateur à alimentation d’air. Demander toujours à un surveillant dûment formé de se tenir à proximité. Des fumées et des gaz de soudage peuvent déplacer l’air et abaisser le niveau d’oxygène provoquant des blessures ou des accidents mortels. S’assurer que l’air de respiration ne présente aucun danger. Ne pas souder dans des endroits situés à proximité d’opérations de dégraissage, de nettoyage ou de pulvérisation. La chaleur et les rayons de l’arc peuvent réagir en présence de vapeurs et former des gaz hautement toxiques et irritants. Ne pas souder des métaux munis d’un revêtement, tels que l’acier galvanisé, plaqué en plomb ou au cadmium à moins que le revêtement n’ait été enlevé dans la zone de soudure, que l’endroit soit bien ventilé, et si nécessaire, en portant un respirateur à alimentation d’air. Les revêtements et tous les métaux renfermant ces éléments peuvent dégager des fumées toxiques en cas de soudage. OM-186 895 Page 5 LES RAYONS DE L’ARC peuvent provoquer des brûlures dans les yeux et sur la peau. Le rayonnement de l’arc du procédé de soudage génère des rayons visibles et invisibles intenses (ultraviolets et infrarouges) susceptibles de provoquer des brûlures dans les yeux et sur la peau. Des étincelles sont projetées pendant le soudage. D Porter un casque de soudage muni d’un écran de filtre approprié pour protéger votre visage et vos yeux pendant le soudage ou pour regarder (voir ANSI Z49.1 et Z87.1 énuméré dans les normes de sécurité). D Porter des protections approuvés pour les oreilles si le niveau sondre est trop élevé. D Utiliser des écrans ou des barrières pour protéger des tiers de l’éclair et de l’éblouissement; demander aux autres personnes de ne pas regarder l’arc. D Porter des vêtements de protection constitué dans une matière durable, résistant au feu (cuir ou laine) et une protection des pieds. LE SOUDAGE peut provoquer un incendie ou une explosion. Le soudage effectué sur des conteneurs fermés tels que des réservoirs, tambours ou des conduites peut provoquer leur éclatement. Des étincelles peuvent être projetées de l’arc de soudure. La projection d’étincelles, des pièces chaudes et des équipements chauds peut provoquer des incendies et des brûlures. Le contact accidentel de l’électrode avec des objets métalliques peut provoquer des étincelles, une explosion, un surchauffement ou un incendie. Avant de commencer le soudage, vérifier et s’assurer que l’endroit ne présente pas de danger. D Se protéger et d’autres personnes de la projection d’étincelles et de métal chaud. D Ne pas souder dans un endroit là où des étincelles peuvent tomber sur des substances inflammables. D Déplacer toutes les substances inflammables à une distance de 10,7 m de l’arc de soudage. En cas d’impossibilité les recouvrir soigneusement avec des protections homologués. D Des étincelles et des matériaux chauds du soudage peuvent facilement passer dans d’autres zones en traversant de petites fissures et des ouvertures. D Surveiller tout déclenchement d’incendie et tenir un extincteur à proximité. D Le soudage effectué sur un plafond, plancher, paroi ou séparation peut déclencher un incendie de l’autre côté. D Ne pas effectuer le soudage sur des conteneurs fermés tels que des réservoirs, tambours, ou conduites, à moins qu’ils n’aient été préparés correctement conformément à AWS F4.1 (voir les normes de sécurité). D Brancher le câble sur la pièce le plus près possible de la zone de soudage pour éviter le transport du courant sur une longue distance par des chemins inconnus éventuels en provoquant des risques d’électrocution et d’incendie. D Ne pas utiliser le poste de soudage pour dégeler des conduites gelées. D En cas de non utilisation, enlever la baguette d’électrode du porteélectrode ou couper le fil à la pointe de contact. D Porter des vêtements de protection dépourvus d’huile tels que des gants en cuir, une chemise en matériau lourd, des pantalons sans revers, des chaussures hautes et un couvre chef. D Avant de souder, retirer toute substance combustible de vos poches telles qu’un allumeur au butane ou des allumettes. DES PARTICULES VOLANTES peuvent blesser les yeux. D Le soudage, l’écaillement, le passage de la pièce à la brosse en fil de fer, et le meulage génèrent des étincelles et des particules métalliques volantes. Pendant la période de refroidissement des soudures, elles risquent de projeter du laitier. D Porter des lunettes de sécurité avec écrans latéraux ou un écran facial. OM-186 895 Page 6 LES ACCUMULATIONS DE GAZ risquent de provoquer des blessures ou même la mort. D D Fermer l’alimentation du gaz protecteur en cas de non utilisation. Veiller toujours à bien aérer les espaces confinés ou se servir d’un respirateur d’adduction d’air homologué. DES PIÈCES CHAUDES peuvent provoquer des brûlures graves. D Ne pas toucher des parties chaudes à mains nues D Prévoir une période de refroidissement avant d’utiliser le pistolet ou la torche. LES CHAMPS MAGNÉTIQUES peuvent affecter les stimulateurs cardiaques. D D Porteurs de stimulateur cardiaque, restez à distance. Les porteurs d’un stimulateur cardiaque doivent d’abord consulter leur médecin avant de s’approcher des opérations de soudage à l’arc, de gougeage ou de soudage par points. LE BRUIT peut affecter l’ouïe. Le bruit des processus et des équipements peut affecter l’ouïe. D Porter des protections approuvés pour les oreilles si le niveau sondre est trop élevé. Si des BOUTEILLES sont endommagées, elles pourront exploser. Des bouteilles de gaz protecteur contiennent du gaz sous haute pression. Si une bouteille est endommagée, elle peut exploser. Du fait que les bouteilles de gaz font normalement partie du procédé de soudage, les manipuler avec précaution. D Protéger les bouteilles de gaz comprimé d’une chaleur excessive, des chocs mécaniques, du laitier, des flammes ouvertes, des étincelles et des arcs. D Placer les bouteilles debout en les fixant dans un support stationnaire ou dans un porte-bouteilles pour les empêcher de tomber ou de se renverser. D Tenir les bouteilles éloignées des circuits de soudage ou autres circuits électriques. D Ne jamais placer une torche de soudage sur une bouteille à gaz. D Une électrode de soudage ne doit jamais entrer en contact avec une bouteille. D Ne jamais souder une bouteille pressurisée – risque d’explosion. D Utiliser seulement des bouteilles de gaz protecteur, régulateurs, tuyaux et raccords convenables pour cette application spécifique; les maintenir ainsi que les éléments associés en bon état. D Ne pas tenir la tête en face de la sortie en ouvrant la soupape de la bouteille. D Maintenir le chapeau de protection sur la soupape, sauf en cas d’utilisation ou de branchement de la bouteille. D Lire et suivre les instructions concernant les bouteilles de gaz comprimé, les équipements associés et les publications P-1 CGA énumérées dans les normes de sécurité. 1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance Risque D’INCENDIE OU D’EXPLOSION. DES ORGANES MOBILES peuvent provoquer des blessures. D Ne pas placer l’appareil sur, au-dessus ou à proximité de surfaces infllammables. D Rester à l’écart des organes mobiles comme le ventilateur. D Maintenir fermés et fixement en place les portes, panneaux, recouvrements et dispositifs de protection. D Ne pas installer l’appareil à proximité de produits inflammables D Ne pas surcharger l’installation électrique – s”assurer que l’alimentation est correctement dimensionné et protégé avant de mettre l’appareil en service. LE RAYONNEMENT HAUTE FRÉQUENCE (H.F.) risque de provoquer des interférences. LA CHUTE DE L’APPAREIL peut blesser. D Utiliser l’anneau de levage uniquement pour soulever l’appareil, NON PAS les chariot, les bouteilles de gaz ou tout autre accessoire. D Utiliser un engin d’une capacité appropriée pour soulever l’appareil. D En utilisant des fourches de levage pour déplacer l’unité, s’assurer que les fourches sont suffisamment longues pour dépasser du côté opposé de l’appareil. L’EMPLOI EXCESSIF peut SURCHAUFFER L’ÉQUIPEMENT. D D D D D D Prévoir une période de refroidissement, respecter le cycle opératoire nominal. D Réduire le courant ou le cycle opératoire avant de recommancer le soudage. LE SOUDAGE À L’ARC risque de provoquer des interférences. D Ne pas obstruer les passages d’air du poste. LES CHARGES ÉLECTROSTATIQUES peuvent endommager les circuits imprimés. D Établir la connexion avec la barrette de terre avant de manipuler des cartes ou des pièces. D Utiliser des pochettes et des boîtes antistatiques pour stocker, déplacer ou expédier des cartes de circuits imprimes. DES ORGANES MOBILES peuvent provoquer des blessures. D Ne pas s’approcher des organes mobiles. D Ne pas s’approcher des points de coincement tels que des rouleaux de commande. LES FILS DE SOUDAGE peuvent provoquer des blessures. D Ne pas appuyer sur la gachette avant d’en avoir reçu l’instruction. D Ne pas diriger le pistolet vers soi, d’autres personnes ou toute pièce mécanique en engageant le fil de soudage. D Le rayonnement haute frequence peut provoquer des interférences avec les équipements de radio–navigation et de communication, les services de sécurité et les ordinateurs. Demander seulement à des personnes qualifiées familiarisées avec des équipements électroniques de faire fonctionner l’installation. L’utilisateur est tenu de faire corriger rapidement par un électricien qualifié les interférences résultant de l’installation. Si le FCC signale des interférences, arrêter immédiatement l’appareil. Effectuer régulièrement le contrôle et l’entretien de l’installation. Maintenir soigneusement fermés les portes et les panneaux des sources de haute fréquence, maintenir les éclateurs à une distance correcte et utiliser une terre et et un blindage pour réduire les interférences éventuelles. D D D D D D L’énergie électromagnétique risque de provoquer des interférences pour l’équipement électronique sensible tel que les ordinateurs et l’équipement commandé par ordinateur tel que les robots. Veiller à ce que tout l’équipement de la zone de soudage soit compatible électromagnétiquement. Pour réduire la possibilité d’interférence, maintenir les câbles de soudage aussi courts que possible, les grouper, et les poser aussi bas que possible (ex. par terre). Veiller à souder à une distance de 100 mètres de tout équipement électronique sensible. Veiller à ce que ce poste de soudage soit posé et mis à la terre conformément à ce mode d’emploi. En cas d’interférences après avoir pris les mesures précédentes, il incombe à l’utilisateur de prendre des mesures supplémentaires telles que le déplacement du poste, l’utilisation de câbles blindés, l’utilisation de filtres de ligne ou la pose de protecteurs dans la zone de travail. LES CHAMPS MAGNÉTIQUES peuvent affecter les stimulateurs cardiaques. D Porteurs de stimulateur cardiaque, restez à distance. D Les porteurs d’un stimulateur cardiaque doivent d’abord consulter leur médecin avant de s’approcher des opérations de soudage à l’arc, de gougeage ou de soudage par points. OM-186 895 Page 7 1-4. Principales normes de sécurité Safety in Welding and Cutting, norme ANSI Z49.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL 33126 Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent of Documents, U.S. Government Printing Office, Washington, D.C. 20402. Recommended Safe Practice for the Preparation for Welding and Cutting of Containers That Have Held Hazardous Substances, norme AWS F4.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL 33126 National Electrical Code, NFPA Standard 70, de la National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, de la Compressed Gas Association, 1235 Jefferson Davis Highway, Suite 501, Arlington, VA 22202. Règles de sécurité en soudage, coupage et procédés connexes, norme CSA W117.2, de l’Association canadienne de normalisation, vente de normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3. Safe Practices For Occupation And Educational Eye And Face Protection, norme ANSI Z87.1, de l’American National Standards Institute, 1430 Broadway, New York, NY 10018. Cutting and Welding Processes, norme NFPA 51B, de la National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. 1-5. Information sur les champs électromagnétiques Données sur le soudage électrique et sur les effets, pour l’organisme, des champs magnétiques basse fréquence Afin de réduire les champs électromagnétiques dans l’environnement de travail, respecter les consignes suivantes : 1 Le courant de soudage, pendant son passage dans les câbles de soudage, causera des champs électromagnétiques. Il y a eu et il y a encore un certain souci à propos de tels champs. Cependant, après avoir examiné plus de 500 études qui ont été faites pendant une période de recherche de 17 ans, un comité spécial ruban bleu du National Research Council a conclu: “L’accumulation de preuves, suivant le jugement du comité, n’a pas démontré que l’exposition aux champs magnétiques et champs électriques à haute fréquence représente un risque à la santé humaine”. Toutefois, des études sont toujours en cours et les preuves continuent à être examinées. En attendant que les conclusions finales de la recherche soient établies, il vous serait souhaitable de réduire votre exposition aux champs électromagnétiques pendant le soudage ou le coupage. OM-186 895 Page 8 2 3 4 5 Garder les câbles ensembles en les torsadant ou en les attachant avec du ruban adhésif. Mettre tous les câbles du côté opposé de l’opérateur. Ne pas courber pas et ne pas entourer pas les câbles autour de votre corps. Garder le poste de soudage et les câbles le plus loin possible de vous. Relier la pince de masse le plus près possible de la zone de soudure. Consignes relatives aux stimulateurs cardiaques : Les personnes qui portent un stimulateur cardiaque doivent avant tout consulter leur docteur. Si vous êtes déclaré apte par votre docteur, il est alors recommandé de respecter les consignes ci–dessus. SECTION 2 – DEFINITIONS 2-1. Warning Label Definitions A B 1 1.1 2 2.1 3 3.1 4 4.1 1.2 2.2 1.3 2.3 3.2 + 5 C 3.3 + + 6 + S-178 936 A. Warning! Watch Out! There are possible hazards as shown by the symbols. B. Drive rolls can injure fingers. C. Welding wire and drive parts are at welding voltage during operation – keep hands and metal objects clear. 1 Electric shock can kill. 1.1 Wear dry insulating gloves. Do not touch electrode with bare hand. Do not wear wet or damaged gloves. 1.2 Protect yourself from electric shock by insulating yourself from work and ground. 1.3 Disconnect input plug or power before working on machine. 2 Breathing welding fumes can be hazardous to your health. 2.1 Keep your head out of the fumes. 2.2 Use forced ventilation or local exhaust to remove the fumes. 2.3 Use ventilating fan to remove fumes. 3 Welding sparks can cause explosion or fire. 3.1 Keep flammables away from welding. Don’t weld near flammables. 3.2 Welding sparks can cause fires. Have a fire extinguisher nearby and have a watch person ready to use it. 3.3 Do not weld on drums or any closed containers. 4 Arc rays can burn eyes and injure skin. 4.1 Wear hat and safety glasses. Use ear protection and button shirt collar. Use welding helmet with correct shade of filter. Wear complete body protection. 5 Become trained and read the instructions before working on the machine or welding. 6 Do not remove or paint over (cover) the label. OM-186 895 Page 9 2-2. Rating Label For CE Products S/N: U1= 24 V I1= 7.0 A U2= 100 V 1 50/60 Hz IP 21 I2= 500 A X 100 % 178 794-A 2-3. Symbols And Definitions NOTE Some symbols are found only on CE products. On A IP Off Input Volts Alternating Current Hertz Circuit Breaker Wire Feed Primary Voltage Gas Metal Arc Welding (GMAW) Gun Line Connection Purge Spot Weld Time Spot Weld Continuous Weld Burnback Time Preflow Time Postflow Time Read Instructions Amperes Degree Of Protection Jog U2 Load Voltage OM-186 895 Page 10 V Hz U1 I1 Primary Current I2 Rated Current Output X U1 Duty Cycle Primary Voltage SECTION 3 – INSTALLATION 3-1. Specifications Type of Input Power Welding Power Source Type 24 Volts AC Single Phase 7 Amperes 50/60 Hz Constant Voltage (CV) DC With 14-Pin And Contactor Control Wire Feed Speed Range 1.9 To 19 mpm (75 to 750 ipm) Wire Diameter Range Welding Circuit Rating 0.6 To 2 mm (.023 To 5/64 in) 100 Volts, 500 Amperes, 100% Duty Cycle Max Spool Weight: 27 kg (60 lb) IP Rating Overall Dimensions Weight Length: 597 mm (23-1/2 in) IP 21 Width: 273 mm (10-3/4 in) 15.9 kg (35 lb) Height: 279 mm (11 in) 3-2. Site Selection 5 6 1 1 Wire Feeder 2 Lifting Eye 3 Rubber Feet 4 Slot Choose slot that allows all rubber feet to sit securely on top of welding power source. 7 5 Wire Spool/Reel 6 Gas Cylinder (Customer Supplied) 7 Welding Power Source Y Do not put feeder where welding wire hits cylinder. Y Do not move or operate equipment when it could tip. 8 Lifting Handle Y Manually use handle to move or briefly lift feeder. 2 4 3 Y Do not use lifting hook or other devices to lift or suspend feeder by the handle. 8 801 920-C / Ref. 152 468-A / 155 242 / 801 919-C / 188 674 OM-186 895 Page 11 3-3. Gun Recommendation Table Process Gun GMAW – Hard or Corded Wires M25 Or M40 FCAW – Self-Shielding Wires GA-40GL 3-4. Equipment Connection Diagrams 1 CV Welding Power Source With 24 VAC Power 2 CV Welding Power Source Without 24 VAC Power 115 Volts AC /24 Volts AC Power Adapter 14-Pin Control Cord Weld Cable (Required) Work 3 4 5 6 1 4 6 3 5 2 115VAC 4 Contactor 6 5 3-5. 14-Pin Receptacle, Shielding Gas And Optional Volt Sense Lead 3 2 1 Gas Hose With 5/8-18 Righthand Thread Fittings (Customer Supplied) 2 14 Pin Receptacle RC9 Use interconnecting cord to make connection to welding power source. 3 Tools Needed: Power Switch 1 5/8, 11/16 in 801 921-C OM-186 895 Page 12 3-6. 14-Pin Receptacle Information Pin* J I N H G L M F A 24 volts ac with respect to pin G. B Contact closure to A completes 24 volts ac contactor control circuit. B G Circuit common for 24 volts AC circuit. C C +10 volts dc output to remote control with respect to pin D. D D Remote control circuit common. E 0 to +10 volts dc input command signal from remote control with respect to pin D. F Current feedback; 0 to 10 volts dc, 1 V/100 A H Voltage feedback; 0 to 10 volts dc, 1 V/10 arc volts A K Pin Information E *The remaining pins are not used. Ref. S-0004-A 3-7. Connecting Welding Gun And Weld Cable 1 Gun/Feeder Adapter 2 Gun Connector Insert gun connector into adapter. Tighten locking ring. 1 3 Weld Cable Terminal 4 Weld Cable From Welding Power Source 2 4 3 Tools Needed: 9/16, 5/8 in 801 922-B OM-186 895 Page 13 3-8. Optional Meter Circuit Board Settings 1 Meter Circuit Board 2 DIP Switch S2 Set DIP switch S2 for type of welding power source, and desired wire feed speed display (see illustration). Reinstall wrapper. 1 2 1 2 X Means switch position does not affect specified function. . Means switch must be in this position. Voltage Sensing Function Using arc voltage sensing lead: Set switches as shown and connect PLG42 and PLG43 in unit wiring harness. PLG41 remains unconnected. Digital Meter Display Meters/Minute 1 1 2 3 4 2 3 5 Inches/Minute 1 2 4 Or Or Using 14-pin receptacle voltage feedback: Set switches as shown and connect PLG42 and PLG41 in unit wiring harness. PLG43 remains unconnected. 1 3 5 4 2 3 4 5 5 Tools Needed: 1/4 in 801 925-C / Ref. 186 266 OM-186 895 Page 14 3-9. Motor Start/Burnback Control To change wire feed starting speed proceed as follows: Turn Off unit and welding power source. 1 Remove wrapper. 1 2 Motor Board PC1 Motor Start Control Potentiometer R73 Remove protective white rubber cap before making adjustment. Adjust potentiometer R73 using a small nonconductive screwdriver. Rotate potentiometer clockwise to increase time it takes the motor to ramp up to speed. 3 2 Burnback Potentiometer R42 Remove protective white rubber cap before making adjustment. Adjust potentiometer R42 using a small nonconductive screwdriver. Rotate potentiometer clockwise to increase burnback time. Reinstall wrapper. Tools Needed: 3 Non-Conductive 1/4 in 801 925-C / 192 653 OM-186 895 Page 15 3-10. Installing Wire Guide And Drive Roll Install and secure inlet wire guide on either assembly, and intermediate wire guide on 4 drive roll assembly only. Install drive rolls and turn drive roll nut one click. During maintenance intervals, remove drive rolls, and clean grooves using a wire brush. Check groove of drive roll for pitting or increase in the depth of the groove indicating drive roll is worn out. Tools Needed: 3/8 in 801 923-C OM-186 895 Page 16 3-11. Installing And Threading Welding Wire 1 2 Retaining Ring Hub Tension Adjustment Nut If necessary, move hub on support for use of different size wire spool. 1 2 Remove retaining ring, and install spool so hub pin fits spool hole. Reinstall retaining ring. 3 Adjust tension nut so wire is taut when wire feed stops. 3 Pressure Assembly Adjustment Knob Lay gun cable out straight. A Open pressure assembly, hold wire tightly, and cut off end. Push wire through guides into gun. B Close and tighten pressure assembly. Press JOG button until wire comes out gun. C To adjust drive roll pressure, press gun trigger to feed wire against wood surface. Tighten knob so wire does not slip. Cut off wire. Close door. A B C Tighten WOOD Tools Needed: 15/16 in Ref. 801 924-B / S-0627-A OM-186 895 Page 17 SECTION 4 – OPERATION 4-1. Front Panel Controls 1 Optional Voltage/Wire Speed Meter 2 Optional Voltage/Wire Speed Switch 1 2 Use to choose volts or wire feed speed display. 3 3 4 Optional Remote Voltage Control Use to set welding power source voltage at the wire feeder. Numbers are for reference only. 4 Wire Speed Control 5 Jog/Purge Switch Use Jog position to momentarily feed welding wire at speed set on Wire Speed control without energizing welding circuit or shielding gas valve. Use Purge position to momentarily energize gas valve to purge air from gun or adjust gas regulator. 5 6 Trigger Hold Switch Push up to weld without holding gun trigger throughout the weld cycle. To start weld cycle, press and release gun trigger within three seconds after an arc has been struck. To end weld, press and release gun trigger. 6 Power switch is on rear panel (see Section 3-5) Ref. 188 340-A OM-186 895 Page 18 4-2. Optional Side Panel Controls 1 Preflow Control Control sets time gas flows before welding wire is energized. Time range is 0 to 5 seconds. 1 2 Postflow Control Control sets time gas flows after completion of burnback. Time range is 0 to 5 seconds. 3 2 Spot Time Control Factory set for 0.25 to 5 seconds of spot time. Rotating knob fully counterclockwise selects an untimed continuous weld. Close side door. 3 Ref. 801 923-C / Ref. 186 589 SECTION 5 – MAINTENANCE & TROUBLESHOOTING 5-1. Routine Maintenance Y Disconnect power before maintaining. 3 Months Repair Or Replace Cracked Weld Cable Replace Unreadable Labels Clean And Tighten Weld Terminals Replace Cracked Parts 14-Pin Cord Gun Cable Gas Hose 6 Months Clean Drive Rolls OR Blow Out Or Vacuum Inside, During Heavy Service, Clean Monthly OM-186 895 Page 19 5-2. Overload Protection Y Turn Off wire feeder and welding power source. Stop engine on welding generator. 1 1 Circuit Breaker CB1 CB1 protects wire feeder from overload. Correct problem and manually reset breaker. 801 921-C 5-3. Troubleshooting Trouble Remedy Wire does not feed, unit completely inop- Turn Power switch On. erative. Check 14–pin receptacle RC9 connections. Check input power. Wire does not feed. Check circuit breaker CB1. (see Section 5-2) Check gun trigger connection at wire feeder. Check gun trigger leads and trigger switch. See gun Owner’s Manual. Have Factory Authorized Service Agent check drive motor and control board PC1. Wire feeds erratically. Readjust hub tension and drive roll pressure (see Section 3-11). Use correct size drive roll (see Parts List). Clean or replace dirty or worn drive roll (see Section 3-10). Remove weld spatter around nozzle opening. Replace contact tip or liner. See gun Owner’s Manual. Have Factory Authorized Service Agent check drive motor and control board PC1. Wire feeds when Jog switch is pressed Check gun trigger connection at wire feeder. Check gun trigger leads and trigger switch. See gun Owner’s but not when gun trigger is pressed. Manual. Wire feeds as soon as power is applied. Check gun trigger. See gun Owner’s Manual. Wire does not feed until trigger is Check for short between gun trigger leads and weld cable. Repair or replace gun trigger leads. pressed but continues to feed after trigger is released. Gas valve rattles loudly and wire feeds Check for short between gun trigger leads and weld cable. Repair or replace gun trigger leads. slowly or erratically. Gas does not flow; wire feeds. OM-186 895 Page 20 Check gas valve and flowmeter. SECTION 6 – ELECTRICAL DIAGRAM 210 937-A Figure 6-1. Circuit Diagram For Wire Feeder With Optional Equipment OM-186 895 Page 21 SECTION 7 – PARTS LIST 7 8 6 9 10 11 12 3 13 2 12 11 5 1 14 4 15 16 50 23 22 49 21 24 17 Figure 7-2 & Figure 7-3 – 48 20 19 18 51 52 53 25 26 27 47 28 46 29 30 54 45 39 40 42 44 23 43 41 37 31 38 . Hardware is common and 801 990-E not available unless listed. Figure 7-1. Main Assembly OM-186 895 Page 22 36 32 33 34 35 Item No. Dia. Mkgs. Part No. Description Quantity Figure 7-1. Main Assembly . . . 1 . . . . . . . . . . . . . 089 899 . . . LATCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 2 . . . . . . . . . . . . +198 650 . . . WRAPPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 3 . . . . . . . . . . . . . 178 936 . . . LABEL, warning electric shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 4 . . . . . . . . . . . . . 187 909 . . . HANDLE, lifting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . . . . . . . 604 423 . . . GRIP, handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 5 . . . . . . . . . . . . . 188 674 . . . LABEL, caution incorrect lifting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 6 . . . . . . . . . . . . . 072 094 . . . HUB & SPINDLE ASSEMBLY, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 7 . . . . . . . . . . . . . 058 427 . . . . RING, retaining spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 8 . . . . . . . . . . . . . 180 572 . . . . SHAFT, spool support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 9 . . . . . . . . . . . . . 010 233 . . . . SPRING, cprsn .970 OD x .120 wire x 1.250 . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 10 . . . . . . . . . . . . . 057 971 . . . . WASHER, flat stl keyed 1.500dia x .125thk . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 11 . . . . . . . . . . . . . 010 191 . . . . WASHER, fbr .656 ID x 1.500 OD x .125thk . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 12 . . . . . . . . . . . . . 058 628 . . . . WASHER, brake stl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 13 . . . . . . . . . . . . . 058 428 . . . . HUB, spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 14 . . . . . . . . . . . . . 135 205 . . . . NUT, stl slflkg hex reg .625-11 w/nylon insert . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 15 . . . . . . . . . . . . . 137 461 . . . BASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 16 . . . . . . . . . . . . . 134 306 . . . FOOT, rbr 1.250dia x 1.375 high . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 . . . 17 . . . . PC1 . . . . 201 010 . . . CIRCUIT CARD, motor speed control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (Eff w/KK008806 for I-22 models, Eff w/KK036472 for I-24 models) . . . . . 1 . . . 17 . . . . PC1 . . . . 186 328 . . . CIRCUIT CARD, motor speed control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (Prior to KK008806 for I-22 models, Prior to KK036472 for I-24 models) . 1 . . . . . . . . . PLG1 . . . 115 093 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . PLG3 . . . 115 092 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . PLG4 . . . 115 091 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . PLG5 . . . 130 203 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 18 . . . . . . . . . . . . . 134 201 . . . STAND-OFF SUPPORT, PC card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 . . . 19 . . . . . . . . . . . . . 131 181 . . . WIRE GUIDE & NUT (22A Model) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 20 . . . . PC3 . . ♦186 297 . . . CIRCUIT CARD, timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . . . . . ♦098 691 . . . STAND-OFF, No 6-32 x .500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . PLG1 . ♦115 093 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . PLG3 . ♦135 409 . . . CONNECTOR & PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . PLG33 . ♦115 092 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . PLG51 . ♦115 091 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 21 . . . . . . . . . . . ♦176 518 . . . FITTING, pipe brs elb 1/4NPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 22 . . . . . . . . . . . ♦188 408 . . . FITTING, barb flow switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 23 . . . . . . . . . . . ♦188 442 . . . WASHER, shldr .515 ID 1.000 OD x .094thk . . . . . . . . . . . . . . . . . . . . . . . . . 8 . . . 24 . . . . . . . . . . . ♦163 603 . . . SWITCH, flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 25 . . . . . . . . . . . ♦601 881 . . . NUT, .500-20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 26 . . . . S1 . . . . . 111 997 . . . SWITCH, rocker SPST 10A 250VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 27 . . . . . . . . . . . . . 112 863 . . . FITTING, hose brs barbed M 1/4tbg x 5/8-18 SAE . . . . . . . . . . . . . . . . . . . . 1 . . . 28 . . . . . . . . . . . ♦126 693 . . . CABLE, sensing 15ft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 29 . . . . . . . . . . . . . 605 227 . . . NUT, nyl hex jam .750NPST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 30 . . . . CB1 . . . . 161 078 . . . CIRCUIT BREAKER, man reset 1P 7A 250VAC . . . . . . . . . . . . . . . . . . . . . . 1 . . . 31 . . . . M1 . . . . 193 188 . . . MOTOR, gear 24VDC 146RPM (consisting of) . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . . . . . . *136 745 . . . . BRUSH & SPRING ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 32 . . . . GS1 . . . . 125 785 . . . VALVE, 24VAC 2 way custom port 1/8 orf . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 33 . . . . RC9 . . . . 152 492 . . . RECEPTACLE W/PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 34 . . . . R1 . . . . . 073 562 . . . POTENTIOMETER, C sltd sft1/T 2W 10K ohm . . . . . . . . . . . . . . . . . . . . . . 1 . . . 35 . . . . R50 . . ♦035 897 . . . POTENTIOMETER, C sltd sft1/T 2W 1K linear . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 36 . . . . S2 . . . . . 134 846 . . . SWITCH, tgl SPTT 6A 125VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 37 . . . . S3 . . . . . 134 847 . . . SWITCH, tgl SPDT 15A 125VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . . . . . . . 187 577 . . . COVER, opening meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . . . . . ♦133 644 . . . FRAME, snap-in switch rocker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 OM-186 895 Page 23 Item No. Dia. Mkgs. Part No. Description Quantity Figure 7-1. Main Assembly (Continued) . . . 38 . . . . PC2 . . ♦186 268 . . . CIRCUIT CARD, meter (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . LCD1 . . . 181 355 . . . . METER, digital . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . PLG15 . ♦115 092 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . PLG16 . ♦131 055 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . . . . . ♦115 443 . . . STAND-OFF, 6-32 x .750 lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 39 . . . . . . . . . . . . . 197 328 . . . CASE ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 40 . . . LED1 . ♦179 203 . . . LED, 5100 2.0V 20MA green . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 41 . . . . . . . . . . . . . . . . . . . . . . . . NAMEPLATE (order by model and serial number) . . . . . . . . . . . . . . . . . . . . 1 . . . 42 . . . . . . . . . . . . . 097 924 . . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 43 . . . . . . . . . . . ♦097 924 . . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 44 . . . . . . . . . . . ♦162 736 . . . FITTING, pipe brs qdisc fem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . . . . . . . . . . . . . . ♦082 367 . . . FITTING, brs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . . . . . ♦188 428 . . . HOSE, water 15.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . . . . . ♦188 429 . . . HOSE, water 25.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 45 . . . . . . . . . . . . . 187 246 . . . ADAPTER, gun/feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 46 . . . . . . . . . . . . . 178 937 . . . LABEL, warning electric shock and pinch . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 47 . . . . . . . . . . . . . 192 875 . . . PLATE, insulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 48 . . . . . . . . Fig 7-2 & 7-3 . . . WIRE DRIVE ASSEMBLIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 49 . . . . . . . . . . . . . 188 149 . . . GUIDE, wire inlet(consisting of) (4 drive roll) . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 50 . . . . . . . . . . . . . 082 050 . . . . LINER, monocoil inlet wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . . . . . . . 082 036 . . . . GUIDE, wire inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . . . . . . . 187 421 . . . TUBE, guide .030-.035 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . . . . . . . 187 422 . . . TUBE, guide .045-.062 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 51 . . . . . . . . . . . . . 010 291 . . . WASHER, flat .625 x 1.250 OD x .125thk nylafil (22A Model) . . . . . . . . . . 1 . . . . . . . . . . . . . . . . . ♦191 002 . . . KIT, gun connection (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . RC2 . . . . 048 282 . . . . RECEPTACLE w/SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 52 . . . . . . . . . . . ♦093 551 . . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 . . . 53 . . . . . . . . . . . ♦186 587 . . . PLATE, control timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 54 . . . . . . . . . . . . . 203 903 . . . Capacitor, assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 +When ordering a component originally displaying a precautionary label, the label should also be ordered. ♦OPTIONAL To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested Replacement Parts. Model and serial number required when ordering parts from your local distributor. OM-186 895 Page 24 Item No. Dia. Mkgs. Part No. Description Quantity Figure 7-2. Drive Assembly, Wire (2 Drive Roll) (Fig 7-1 Item 48) . . . 1 . . . . . . . . . . . . . 602 009 . . . SCREW, .250-20 x 1.250 soc hd hex gr 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 2 . . . . . . . . . . . . . 172 075 . . . CARRIER, drive roll w/component 24 pitch . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 3 . . . . . . . . . . . . . 054 263 . . . SCREW, thumb stl .250-20 x .500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 4 . . . . . . . . . . . . . 010 224 . . . PIN, spring CS .187 x 1.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 5 . . . . . . . . . . . . . 166 072 . . . SPACER, gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 6 . . . . . . . . . . . . . 089 562 . . . FASTENER, pinned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 7 . . . . . . . . . . . . . 085 244 . . . WASHER, cupped stl .328 ID x .812 OD x .125 . . . . . . . . . . . . . . . . . . . . . . 1 . . . 8 . . . . . . . . . . . . . 089 477 . . . SPRING, cprsn .770 OD x .105 wire x 1.225 . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 9 . . . . . . . . . . . . . 085 243 . . . KNOB, adjustment tension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 10 . . . . . . . . . . . . . 166 071 . . . LEVER, mtg pressure gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 11 . . . . . . . . . . . . . 151 828 . . . PIN, cotter hair .054 x .750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 12 . . . . . . . . . . . . . 079 634 . . . PIN, hinge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 13 . . . . . . . . . . . . . 144 172 . . . FITTING, hose brs barbed m 3/16 tbg x .250-20 . . . . . . . . . . . . . . . . . . . . . . 1 . . . 14 . . . . . . . . . . . . . 172 391 . . . HOUSING, adapter gun/feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 15 . . . . . . . . . . . . . 048 449 . . . WASHER, shldr nyl .363 OD x .194 ID x .703 . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 16 . . . . . . . . . . . . . 124 778 . . . KNOB, T 2.000 bar w/.312-18 x 1.000lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 17 . . . . . . . . . . . . . 605 308 . . . RING, rtng ext .500 shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 18 . . . . . . . . . . . . . 079 625 . . . WASHER, wave .500 ID x .750 OD x .015thk . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 19 . . . . . . . . . . . . . 121 271 . . . SCREW, .250-20 x .500 soc hd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 20 . . . . . . . . . . . . . 172 076 . . . CARRIER, drive roll w/components 24 pitch . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 21 . . . . . . . . . . . . . 092 865 . . . KEY, stl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 9 8 10 11 7 12 6 4 5 3 2 1 13 14 21 20 15 19 17 16 18 802 019-A Figure 7-2. Drive Assembly, Wire (2 Drive Roll ) To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested Replacement Parts. Model and serial number required when ordering parts from your local distributor. OM-186 895 Page 25 Item No. Dia. Mkgs. Part No. Description Quantity Figure 7-3. Drive Assembly, Wire(4 Drive Roll) (Fig 7-1 Item 48) . . . 1 . . . . . . . . . . . . . 602 009 . . . SCREW, .250-20 x 1.250 soc hd hex gr 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 . . . 2 . . . . . . . . . . . . . 172 075 . . . CARRIER, drive roll w/component 24 pitch . . . . . . . . . . . . . . . . . . . . . . . . . . 4 . . . 3 . . . . . . . . . . . . . 166 072 . . . SPACER, gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 . . . 4 . . . . . . . . . . . . . 054 263 . . . SCREW, thumb stl .250-20 x .500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 5 . . . . . . . . . . . . . 010 224 . . . PIN, spring CS .187 x 1.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 6 . . . . . . . . . . . . . 089 562 . . . FASTENER, pinned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 7 . . . . . . . . . . . . . 085 244 . . . WASHER, cupped stl .328 ID x .812 OD x .125 . . . . . . . . . . . . . . . . . . . . . . 2 . . . 8 . . . . . . . . . . . . . 089 477 . . . SPRING, cprsn .770 OD x .105 wire x 1.225 . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 9 . . . . . . . . . . . . . 085 243 . . . KNOB, adjustment tension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 10 . . . . . . . . . . . . . 166 071 . . . LEVER, mtg pressure gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 11 . . . . . . . . . . . . . 079 634 . . . PIN, hinge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 12 . . . . . . . . . . . . . 151 828 . . . PIN, cotter hair .054 x .750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 13 . . . . . . . . . . . . . 166 338 . . . LEVER, mtg pressure gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 14 . . . . . . . . . . . . . 605 308 . . . RING, rtng ext .500 shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 15 . . . . . . . . . . . . . 187 325 . . . INSULATOR, drive assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 16 . . . . . . . . . . . . . 144 172 . . . FITTING, hose brs barbed m 3/16 tbg x .250-20 . . . . . . . . . . . . . . . . . . . . . . 1 . . . 17 . . . . . . . . . . . . . 166 337 . . . HOUSING, adapter gun/feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 18 . . . . . . . . . . . . . 168 590 . . . BUSHING, insulating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 19 . . . . . . . . . . . . . 072 010 . . . WASHER, shldr .316 ID x .812 OD x .187thk . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 20 . . . . . . . . . . . . . 124 778 . . . KNOB, T 2.000 bar w/.312-18 x 1.000lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 21 . . . . . . . . . . . . . 079 625 . . . WASHER, wave .500 ID x .750 OD x .015thk . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . 22 . . . . . . . . . . . . . 092 865 . . . KEY, stl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 23 . . . . . . . . . . . . . 172 077 . . . CARRIER, drive roll keyed 24 pitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . 24 . . . . . . . . . . . . . 121 271 . . . SCREW, .250-20 x .500 soc hd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 10 12 11 13 9 14 8 7 6 5 15 4 3 16 2 1 21 24 22 23 20 19 18 17 802 018-A Figure 7-3. Drive Assembly, Wire (4 Drive Roll ) To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested Replacement Parts. Model and serial number required when ordering parts from your local distributor. OM-186 895 Page 26 Table 7-1. Drive Roll And Wire Guide Kits (2 Drive Roll) NOTE Base selection of drive rolls upon the following recommended usages: 1. V-Grooved rolls for hard wire. 2. U-Grooved rolls for soft and soft shelled cored wires. 3. U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types). 4. V-Knurled rolls for hard shelled cored wires. 5. Drive roll types may be mixed to suit particular requirements (example: V-Knurled roll in combination with U-Grooved). Wire Diameter Fraction Decimal Metric .023/.025 in .023/.025 in .030 in Kit No. Drive Roll Part No. Type 0.6 mm 087 131 087 130 V-Grooved 056 192 .030 in 0.8 mm 079 594 053 695 V-Grooved 056 192 .035 in .035 in 0.9 mm 079 595 053 700 V-Grooved 056 192 .040 in .040 in 1.0 mm 161 189 053 696 V-Grooved 056 192 .045 in .045 in 1.2 mm 079 596 053 697 V-Grooved 056 193 .052 in .052 in 1.3 mm 079 597 053 698 V-Grooved 056 193 1/16 in .062 in 1.6 mm 079 598 053 699 V-Grooved 056 195 .035 in .035 in 0.9 mm 044 749 072 000 U-Grooved 056 192 .045 in .045 in 1.2 mm 079 599 053 701 U-Grooved 056 193 .052 in .052 in 1.3 mm 079 600 053 702 U-Grooved 056 193 1/16 in 5/64 in .062 in .079 in 1.6 mm 2.0 mm 079 601 079 602 053 706 053 704 U-Grooved U-Grooved 056 195 056 195 .035 in .035 in 0.9 mm 079 606 132 958 V-Knurled 056 192 .045 in .045 in 1.2 mm 079 607 132 957 V-Knurled 056 193 .052 in .052 in 1.3 mm 079 608 132 956 V-Knurled 056 193 1/16 in .062 in 1.6 mm 079 609 132 955 V-Knurled 056 195 .068-.072 in .068-.072 in 1.8 mm 089 984 132 959 V-Knurled 056 195 5/64 in .079 in 2.0 mm 079 610 132 960 V-Knurled 056 195 .045 in .045 in 1.2 mm 083 318 083 489 U-Cogged 056 193 .052 in .052 in 1.3 mm 083 317 083 490 U-Cogged 056 193 1/16 in .062 in 1.6 mm 079 614 053 708 U-Cogged 056 195 5/64 in .079 in 2.0 mm 079 615 053 710 U-Cogged 056 195 Inlet Wire Guide S-0157-C OM-186 895 Page 27 Table 7-2. Drive Roll & Wire Guide Kits (4 Drive Roll) NOTE Base selection of drive rolls upon the following recommended usages: 1. V-Grooved rolls for hard wire. 2. U-Grooved rolls for soft and soft shelled cored wires. 3. U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types). 4. V-Knurled rolls for hard shelled cored wires. 5. Drive roll types may be mixed to suit particular requirements (example: V-Knurled roll in combination with U-Grooved). Wire Diameter Fraction Decimal Metric .023/.025 in .023/.025 in .030 in Kit No. Drive Roll Part No. Type 0.6 mm 087 132 087 130 V-Grooved 056 192 056 206 .030 in 0.8 mm 046 780 053 695 V-Grooved 056 192 056 206 .035 in .035 in 0.9 mm 046 781 053 700 V-Grooved 056 192 056 206 .040 in .040 in 1.0 mm 191 917 053 696 V-Grooved 056 192 056 206 .045 in .045 in 1.2 mm 046 782 053 697 V-Grooved 056 193 056 207 .052 in .052 in 1.3 mm 046 783 053 698 V-Grooved 056 193 056 207 1/16 in .062 in 1.6 mm 046 784 053 699 V-Grooved 056 195 056 209 .035 in .035 in 0.9 mm 044 750 072 000 U-Grooved 056 192 056 206 .045 in .045 in 1.2 mm 046 785 053 701 U-Grooved 056 193 056 207 .052 in .052 in 1.3 mm 046 786 053 702 U-Grooved 056 193 056 207 1/16 in 5/64 in .062 in .079 in 1.6 mm 2.0 mm 046 787 046 788 053 706 053 704 U-Grooved U-Grooved 056 195 056 195 056 209 056 209 .035 in .035 in 0.9 mm 046 792 132 958 V-Knurled 056 192 056 206 .045 in .045 in 1.2 mm 046 793 132 957 V-Knurled 056 193 056 207 .052 in .052 in 1.3 mm 046 794 132 956 V-Knurled 056 193 056 207 1/16 in .062 in 1.6 mm 046 795 132 955 V-Knurled 056 195 056 209 .068-.072 in .068-.072 in Wire Guide Inlet Intermediate 1.8 mm 089 985 132 959 V-Knurled 056 195 056 209 5/64 in .079 in 2.0 mm 046 796 132 960 V-Knurled 056 195 056 209 .045 in .045 in 1.2 mm 083 319 083 489 U-Cogged 056 193 056 207 .052 in .052 in 1.3 mm 083 320 083 490 U-Cogged 056 193 056 207 1/16 in .062 in 1.6 mm 046 800 053 708 U-Cogged 056 195 056 209 5/64 in .079 in 2.0 mm 046 801 053 710 U-Cogged 056 195 056 209 Ref. S-0025-D OM-186 895 Page 28 Notes OM-186 895 Page 29 Notes OM-186 895 Page 30 Effective January 1, 2002 (Equipment with a serial number preface of “LC” or newer) This limited warranty supersedes all previous Miller warranties and is exclusive with no other guarantees or warranties expressed or implied. Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. Your distributor also gives you ... Service You always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor. The expertise of the distributor and Miller is there to help you, every step of the way. * LIMITED WARRANTY – Subject to the terms and conditions below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants to its original retail purchaser that new Miller equipment sold after the effective date of this limited warranty is free of defects in material and workmanship at the time it is shipped by Miller. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS. Within the warranty periods listed below, Miller will repair or replace any warranted parts or components that fail due to such defects in material or workmanship. Miller must be notified in writing within thirty (30) days of such defect or failure, at which time Miller will provide instructions on the warranty claim procedures to be followed. Miller shall honor warranty claims on warranted equipment listed below in the event of such a failure within the warranty time periods. All warranty time periods start on the date that the equipment was delivered to the original retail purchaser, or one year after the equipment is sent to a North American distributor or eighteen months after the equipment is sent to an International distributor. 1. 5 Years Parts – 3 Years Labor * * 2. 3 Years — Parts and Labor * * * * * * 3. Original main power rectifiers Inverters (input and output rectifiers only) Transformer/Rectifier Power Sources Plasma Arc Cutting Power Sources Semi-Automatic and Automatic Wire Feeders Inverter Power Supplies Intellitig Engine Driven Welding Generators (NOTE: Engines are warranted separately by the engine manufacturer.) 1 Year — Parts and Labor Unless Specified * * * * * * * * * * * * * * * * * * DS-2 Wire Feeder Motor Driven Guns (w/exception of Spoolmate Spoolguns) Process Controllers Positioners and Controllers Automatic Motion Devices RFCS Foot Controls Induction Heating Power Sources Water Coolant Systems Flowgauge and Flowmeter Regulators (No Labor) HF Units Grids Maxstar 85, 140 Spot Welders Load Banks Racks Running Gear/Trailers Plasma Cutting Torches (except APT & SAF Models) Field Options (NOTE: Field options are covered under True Blue for the remaining warranty period of the product they are installed in, or for a minimum of one year — whichever is greater.) 4. 6 Months — Batteries 5. 90 Days — Parts * * MIG Guns/TIG Torches Induction Heating Coils and Blankets * * * * * APT, ZIPCUT & PLAZCUT Model Plasma Cutting Torches Remote Controls Accessory Kits Replacement Parts (No labor) Spoolmate Spoolguns Canvas Covers Miller’s True Blue Limited Warranty shall not apply to: 1. Consumable components; such as contact tips, cutting nozzles, contactors, brushes, slip rings, relays or parts that fail due to normal wear. (Exception: brushes, slip rings, and relays are covered on Bobcat, Trailblazer, and Legend models.) 2. Items furnished by Miller, but manufactured by others, such as engines or trade accessories. These items are covered by the manufacturer’s warranty, if any. 3. Equipment that has been modified by any party other than Miller, or equipment that has been improperly installed, improperly operated or misused based upon industry standards, or equipment which has not had reasonable and necessary maintenance, or equipment which has been used for operation outside of the specifications for the equipment. MILLER PRODUCTS ARE INTENDED FOR PURCHASE AND USE BY COMMERCIAL/INDUSTRIAL USERS AND PERSONS TRAINED AND EXPERIENCED IN THE USE AND MAINTENANCE OF WELDING EQUIPMENT. In the event of a warranty claim covered by this warranty, the exclusive remedies shall be, at Miller’s option: (1) repair; or (2) replacement; or, where authorized in writing by Miller in appropriate cases, (3) the reasonable cost of repair or replacement at an authorized Miller service station; or (4) payment of or credit for the purchase price (less reasonable depreciation based upon actual use) upon return of the goods at customer’s risk and expense. Miller’s option of repair or replacement will be F.O.B., Factory at Appleton, Wisconsin, or F.O.B. at a Miller authorized service facility as determined by Miller. Therefore no compensation or reimbursement for transportation costs of any kind will be allowed. TO THE EXTENT PERMITTED BY LAW, THE REMEDIES PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF PROFIT), WHETHER BASED ON CONTRACT, TORT OR ANY OTHER LEGAL THEORY. ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND ANY IMPLIED WARRANTY, GUARANTY OR REPRESENTATION AS TO PERFORMANCE, AND ANY REMEDY FOR BREACH OF CONTRACT TORT OR ANY OTHER LEGAL THEORY WHICH, BUT FOR THIS PROVISION, MIGHT ARISE BY IMPLICATION, OPERATION OF LAW, CUSTOM OF TRADE OR COURSE OF DEALING, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE, WITH RESPECT TO ANY AND ALL EQUIPMENT FURNISHED BY MILLER IS EXCLUDED AND DISCLAIMED BY MILLER. Some states in the U.S.A. do not allow limitations of how long an implied warranty lasts, or the exclusion of incidental, indirect, special or consequential damages, so the above limitation or exclusion may not apply to you. This warranty provides specific legal rights, and other rights may be available, but may vary from state to state. In Canada, legislation in some provinces provides for certain additional warranties or remedies other than as stated herein, and to the extent that they may not be waived, the limitations and exclusions set out above may not apply. This Limited Warranty provides specific legal rights, and other rights may be available, but may vary from province to province. miller_warr 6/02 Owner’s Record Please complete and retain with your personal records. Model Name Serial/Style Number Purchase Date (Date which equipment was delivered to original customer.) Distributor Address City State Zip For Service Call 1-800-4-A-Miller or see our website at www.MillerWelds.com to locate a DISTRIBUTOR or SERVICE AGENCY near you. Always provide Model Name and Serial/Style Number. Contact your Distributor for: Welding Supplies and Consumables Options and Accessories Personal Safety Equipment Service and Repair Miller Electric Mfg. Co. Replacement Parts Training (Schools, Videos, Books) Technical Manuals (Servicing Information and Parts) Circuit Diagrams Welding Process Handbooks An Illinois Tool Works Company 1635 West Spencer Street Appleton, WI 54914 USA International Headquarters–USA USA Phone: 920-735-4505 Auto-Attended USA & Canada FAX: 920-735-4134 International FAX: 920-735-4125 European Headquarters – United Kingdom Phone: 44 (0) 1204-593493 FAX: 44 (0) 1204-598066 www.MillerWelds.com Contact the Delivering Carrier To: File a claim for loss or damage during shipment. For assistance in filing or settling claims, contact your distributor and/or equipment manufacturer’s Transportation Department. PRINTED IN USA 2002 Miller Electric Mfg. Co. 6/02 ">

Public link updated
The public link to your chat has been updated.
Advertisement