Miller | LH320154A | Owner Manual | Miller XMT 456 CC/CV (230/460 575 VOLT) User manual

Miller XMT 456 CC/CV (230/460 575 VOLT) User manual
OM-2232
202 221N
2007−08
Processes
Invision 456P:
MIG (GMAW) and Pulsed MIG
(GMAW-P) Welding
Flux Cored (FCAW) Welding
XMT 456 CC/CV:
Multiprocess Welding
Description
Invision 456P:
XMT 456 CC/CV:
Invision 456P And
XMT 456 CC/CV
R
R
(230/460 And 575 Volt Models)
File: MIG (GMAW)
Visit our website at
www.MillerWelds.com
From Miller to You
Thank you and congratulations on choosing Miller. Now you can get
the job done and get it done right. We know you don’t have time to do
it any other way.
That’s why when Niels Miller first started building arc welders in 1929,
he made sure his products offered long-lasting value and superior
quality. Like you, his customers couldn’t afford anything less. Miller
products had to be more than the best they could be. They had to be the
best you could buy.
Today, the people that build and sell Miller products continue the
tradition. They’re just as committed to providing equipment and service
that meets the high standards of quality and value established in 1929.
This Owner’s Manual is designed to help you get the most out of your
Miller products. Please take time to read the Safety precautions. They
will help you protect yourself against potential hazards on the worksite.
We’ve made installation and operation quick
and easy. With Miller you can count on years
of reliable service with proper maintenance.
And if for some reason the unit needs repair,
there’s a Troubleshooting section that will
help you figure out what the problem is. The
Miller is the first welding parts list will then help you to decide the
equipment manufacturer in exact part you may need to fix the problem.
the U.S.A. to be registered to
the ISO 9001:2000 Quality Warranty and service information for your
System Standard.
particular model are also provided.
Miller Electric manufactures a full line
of welders and welding related equipment.
For information on other quality Miller
products, contact your local Miller distributor to receive the latest full
line catalog or individual specification sheets. To locate your nearest
distributor or service agency call 1-800-4-A-Miller, or visit us at
www.MillerWelds.com on the web.
Mil_Thank 4/05
Working as hard as you do
− every power source from
Miller is backed by the most
hassle-free warranty in the
business.
TABLE OF CONTENTS
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4. California Proposition 65 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-6. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1. Symboles utilisés . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2. Dangers relatifs au soudage à l’arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance . . . . . .
2-4. Proposition californienne 65 Avertissements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-5. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-6. Information EMF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 − INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2. Duty Cycle and Overheating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-3. Volt-Ampere Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-4. Dimensions And Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-5. Selecting a Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-6. Weld Output Terminals And Selecting Cable Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-7. Connecting Weld Output Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-8. Remote 14 Receptacle Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-9. 115 Volts AC Duplex Receptacle And Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-10. Electrical Service Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-11. Selecting Input Voltage (230/460 Volt Models Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-12. Connecting Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 4 − OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-1. Front Panel Controls For Invision 456P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. Mode and Voltage Control For Invision 456P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3. Meter Functions For Invision 456P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-4. Front Panel Controls For XMT 456 CC/CV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-5. Meter Functions For XMT 456 CC/CV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-6. Mode Switch Settings For XMT 456 CC/CV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-7. Lift-Arc TIG Procedure For XMT 456 CC/CV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 5 − MAINTENANCE AND TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2. Blowing Out Inside of Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-3. Removing Right Side Panel and Measuring Input Capacitor Voltage In 230/460 Volt Models . . . . . . .
5-4. Removing Right Side Panel and Measuring Input Capacitor Voltage in 575 Volt Models . . . . . . . . . . .
5-5. Voltmeter/Ammeter Help Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-6. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 − ELECTRICAL DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 7 − PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPTIONS AND ACCESSORIES
WARRANTY
1
1
1
3
4
4
4
5
5
5
7
8
9
9
11
11
11
12
12
13
14
15
15
16
16
17
18
19
19
19
20
20
21
21
22
23
23
23
24
25
26
27
28
32
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING
som _2007−04
7
Protect yourself and others from injury — read and follow these precautions.
1-1. Symbol Usage
DANGER! − Indicates a hazardous situation which, if
not avoided, will result in death or serious injury. The
possible hazards are shown in the adjoining symbols
or explained in the text.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury. The possible
hazards are shown in the adjoining symbols or explained in the text.
NOTICE − Indicates statements not related to personal injury.
. Indicates special instructions.
This group of symbols means Warning! Watch Out! ELECTRIC
SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult symbols and related instructions below for necessary actions to avoid the
hazards.
1-2. Arc Welding Hazards
The symbols shown below are used throughout this manual
to call attention to and identify possible hazards. When you
see the symbol, watch out, and follow the related instructions
to avoid the hazard. The safety information given below is
only a summary of the more complete safety information
found in the Safety Standards listed in Section 1-5. Read and
follow all Safety Standards.
Only qualified persons should install, operate, maintain, and
repair this unit.
During operation, keep everybody, especially children, away.
D Always verify the supply ground − check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
grounded receptacle outlet.
D When making input connections, attach proper grounding conductor first − double-check connections.
D Keep cords dry, free of oil and grease, and protected from hot metal
and sparks.
D Frequently inspect input power cord for damage or bare wiring −
replace cord immediately if damaged − bare wiring can kill.
D Turn off all equipment when not in use.
D Do not use worn, damaged, undersized, or poorly spliced cables.
D Do not drape cables over your body.
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shocks
or severe burns. The electrode and work circuit is
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also
live when power is on. In semiautomatic or automatic wire welding, the
wire, wire reel, drive roll housing, and all metal parts touching the
welding wire are electrically live. Incorrectly installed or improperly
grounded equipment is a hazard.
D Do not touch live electrical parts.
D Wear dry, hole-free insulating gloves and body protection.
D Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.
D Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
D Use AC output ONLY if required for the welding process.
D If AC output is required, use remote output control if present on
unit.
D Additional safety precautions are required when any of the following electrically hazardous conditions are present: in damp
locations or while wearing wet clothing; on metal structures such
as floors, gratings, or scaffolds; when in cramped positions such
as sitting, kneeling, or lying; or when there is a high risk of unavoidable or accidental contact with the workpiece or ground. For these
conditions, use the following equipment in order presented: 1) a
semiautomatic DC constant voltage (wire) welder, 2) a DC manual
(stick) welder, or 3) an AC welder with reduced open-circuit voltage. In most situations, use of a DC, constant voltage wire welder
is recommended. And, do not work alone!
D Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
D Properly install and ground this equipment according to its
Owner’s Manual and national, state, and local codes.
D If earth grounding of the workpiece is required, ground it directly
with a separate cable.
D Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
D Do not touch electrode holders connected to two welding machines at the same time since double open-circuit voltage will be
present.
D Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
D Wear a safety harness if working above floor level.
D Keep all panels and covers securely in place.
D Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
D Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
D Do not connect more than one electrode or work cable to any
single weld output terminal.
SIGNIFICANT DC VOLTAGE exists in inverter-type
welding power sources after removal of input
power.
D Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section
before touching any parts.
HOT PARTS can cause severe burns.
D Do not touch hot parts bare handed.
D Allow cooling period before working on gun or
torch.
D To handle hot parts, use proper tools and/or
wear heavy, insulated welding gloves and
clothing to prevent burns.
OM-2232 Page 1
FUMES AND GASES can be hazardous.
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health.
D Keep your head out of the fumes. Do not breathe the fumes.
D If inside, ventilate the area and/or use local forced ventilation at the
arc to remove welding fumes and gases.
D If ventilation is poor, wear an approved air-supplied respirator.
D Read and understand the Material Safety Data Sheets (MSDSs)
and the manufacturer’s instructions for metals, consumables,
coatings, cleaners, and degreasers.
D Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watchperson nearby. Welding fumes and gases can displace air and
lower the oxygen level causing injury or death. Be sure the breathing air is safe.
D Do not weld in locations near degreasing, cleaning, or spraying operations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.
D Do not weld on coated metals, such as galvanized, lead, or
cadmium plated steel, unless the coating is removed from the weld
area, the area is well ventilated, and while wearing an air-supplied
respirator. The coatings and any metals containing these elements
can give off toxic fumes if welded.
ARC RAYS can burn eyes and skin.
Arc rays from the welding process produce intense
visible and invisible (ultraviolet and infrared) rays
that can burn eyes and skin. Sparks fly off from the
weld.
D Wear an approved welding helmet fitted with a proper shade of filter lenses to protect your face and eyes when welding or watching
(see ANSI Z49.1 and Z87.1 listed in Safety Standards).
D Wear approved safety glasses with side shields under your
helmet.
D Do not use welder to thaw frozen pipes.
D Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
D Wear oil-free protective garments such as leather gloves, heavy
shirt, cuffless trousers, high shoes, and a cap.
D Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.
D After completion of work, inspect area to ensure it is free of sparks,
glowing embers, and flames.
D Use only correct fuses or circuit breakers. Do not oversize or bypass them.
D Follow requirements in OSHA 1910.252 (a) (2) (iv) and NFPA 51B
for hot work and have a fire watcher and extinguisher nearby.
FLYING METAL or DIRT can injure eyes.
D Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool,
they can throw off slag.
D Wear approved safety glasses with side
shields even under your welding helmet.
BUILDUP OF GAS can injure or kill.
D Shut off shielding gas supply when not in use.
D Always ventilate confined spaces or use
approved air-supplied respirator.
MAGNETIC FIELDS can affect Implanted
Medical Devices.
D Wearers of Pacemakers and other Implanted
Medical Devices should keep away.
D Implanted Medical Device wearers should consult their doctor
and the device manufacturer before going near arc welding, spot
welding, gouging, plasma arc cutting, or induction heating
operations.
D Use protective screens or barriers to protect others from flash,
glare and sparks; warn others not to watch the arc.
NOISE can damage hearing.
D Wear protective clothing made from durable, flame-resistant material (leather, heavy cotton, or wool) and foot protection.
Noise from some processes or equipment can
damage hearing.
WELDING can cause fire or explosion.
Welding on closed containers, such as tanks,
drums, or pipes, can cause them to blow up. Sparks
can fly off from the welding arc. The flying sparks, hot
workpiece, and hot equipment can cause fires and
burns. Accidental contact of electrode to metal objects can cause
sparks, explosion, overheating, or fire. Check and be sure the area is
safe before doing any welding.
D Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
D Do not weld where flying sparks can strike flammable material.
D Protect yourself and others from flying sparks and hot metal.
D Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
D Watch for fire, and keep a fire extinguisher nearby.
D Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
D Do not weld on closed containers such as tanks, drums, or pipes,
unless they are properly prepared according to AWS F4.1 (see
Safety Standards).
D Do not weld where the atmosphere may contain flammable dust,
gas, or liquid vapors (such as gasoline).
D Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly
unknown paths and causing electric shock, sparks, and fire
hazards.
OM-2232 Page 2
D Wear approved ear protection if noise level is
high.
CYLINDERS can explode if damaged.
Shielding gas cylinders contain gas under high
pressure. If damaged, a cylinder can explode. Since
gas cylinders are normally part of the welding
process, be sure to treat them carefully.
D Protect compressed gas cylinders from excessive heat, mechanical shocks, physical damage, slag, open flames, sparks, and arcs.
D Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
D Keep cylinders away from any welding or other electrical circuits.
D Never drape a welding torch over a gas cylinder.
D Never allow a welding electrode to touch any cylinder.
D Never weld on a pressurized cylinder − explosion will result.
D Use only correct shielding gas cylinders, regulators, hoses, and fittings designed for the specific application; maintain them and
associated parts in good condition.
D Turn face away from valve outlet when opening cylinder valve.
D Keep protective cap in place over valve except when cylinder is in
use or connected for use.
D Use the right equipment, correct procedures, and sufficient number of persons to lift and move cylinders.
D Read and follow instructions on compressed gas cylinders,
associated equipment, and Compressed Gas Association (CGA)
publication P-1 listed in Safety Standards.
1-3. Additional Symbols For Installation, Operation, And Maintenance
FIRE OR EXPLOSION hazard.
D Do not install or place unit on, over, or near
combustible surfaces.
D Do not install unit near flammables.
D Do not overload building wiring − be sure power supply system is
properly sized, rated, and protected to handle this unit.
FALLING UNIT can cause injury.
MOVING PARTS can cause injury.
D Keep away from moving parts such as fans.
D Keep all doors, panels, covers, and guards
closed and securely in place.
D Have only qualified persons remove doors, panels, covers, or
guards for maintenance as necessary.
D Reinstall doors, panels, covers, or guards when maintenance is
finished and before reconnecting input power.
D Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
D Use equipment of adequate capacity to lift and
support unit.
D If using lift forks to move unit, be sure forks are
long enough to extend beyond opposite side of
unit.
READ INSTRUCTIONS.
D Read Owner’s Manual before using or servicing unit.
D Use only genuine replacement parts from the
manufacturer.
OVERUSE can cause OVERHEATING
H.F. RADIATION can cause interference.
D Allow cooling period; follow rated duty cycle.
D Reduce current or reduce duty cycle before
starting to weld again.
D Do not block or filter airflow to unit.
FLYING SPARKS can cause injury.
D Wear a face shield to protect eyes and face.
D Shape tungsten electrode only on grinder with
proper guards in a safe location wearing proper
face, hand, and body protection.
D Sparks can cause fires — keep flammables away.
D
D
D
D
STATIC (ESD) can damage PC boards.
D Put on grounded wrist strap BEFORE handling
boards or parts.
D Use proper static-proof bags and boxes to
store, move, or ship PC boards.
ARC WELDING can cause interference.
MOVING PARTS can cause injury.
D Keep away from moving parts.
D Keep away from pinch points such as drive
rolls.
WELDING WIRE can cause injury.
D Do not press gun trigger until instructed to do
so.
D Do not point gun toward any part of the body,
other people, or any metal when threading
welding wire.
D High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communications equipment.
D Have only qualified persons familiar with
electronic equipment perform this installation.
The user is responsible for having a qualified electrician promptly correct any interference problem resulting from the installation.
If notified by the FCC about interference, stop using the
equipment at once.
Have the installation regularly checked and maintained.
Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.
D
D
D
D
D Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.
D Be sure all equipment in the welding area is
electromagnetically compatible.
To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
Locate welding operation 100 meters from any sensitive electronic equipment.
Be sure this welding machine is installed and grounded
according to this manual.
If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables,
using line filters, or shielding the work area.
OM-2232 Page 3
1-4. California Proposition 65 Warnings
Welding or cutting equipment produces fumes or gases
which contain chemicals known to the State of California to
cause birth defects and, in some cases, cancer. (California
Health & Safety Code Section 25249.5 et seq.)
Battery posts, terminals and related accessories contain lead
and lead compounds, chemicals known to the State of
California to cause cancer and birth defects or other
reproductive harm. Wash hands after handling.
For Gasoline Engines:
Engine exhaust contains chemicals known to the State of
California to cause cancer, birth defects, or other reproductive harm.
For Diesel Engines:
Diesel engine exhaust and some of its constituents are
known to the State of California to cause cancer, birth
defects, and other reproductive harm.
1-5. Principal Safety Standards
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
from Global Engineering Documents (phone: 1-877-413-5184, website:
www.global.ihs.com).
Recommended Safe Practices for the Preparation for Welding and Cutting of Containers and Piping, American Welding Society Standard
AWS F4.1, from Global Engineering Documents (phone:
1-877-413-5184, website: www.global.ihs.com).
National Electrical Code, NFPA Standard 70, from National Fire Protection Association, P.O. Box 9101, Quincy, MA 02269-9101 (phone:
617-770-3000, website: www.nfpa.org and www. sparky.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 4221 Walney Road, 5th Floor,
Chantilly, VA 20151 (phone: 703-788-2700, website:www.cganet.com).
Code for Safety in Welding and Cutting, CSA Standard W117.2, from
Canadian Standards Association, Standards Sales, 5060 Mississauga,
Ontario, Canada L4W 5NS (phone: 800-463-6727 or in Toronto
416-747-4044, website: www.csa-international.org).
Safe Practice For Occupational And Educational Eye And Face Protection, ANSI Standard Z87.1, from American National Standards Institute,
25 West 43rd Street, New York, NY 10036–8002 (phone:
212-642-4900, website: www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, from National Fire Protection Association,
P.O. Box 9101, Quincy, MA 02269-9101 (phone: 617-770-3000, website: www.nfpa.org.
OSHA, Occupational Safety and Health Standards for General Industry, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,
and Part 1926, Subpart J, from U.S. Government Printing Office, Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954
(phone: 1-866-512-1800) (there are 10 Regional Offices—phone for
Region 5, Chicago, is 312-353-2220, website: www.osha.gov).
1-6. EMF Information
Considerations About Welding And The Effects Of Low Frequency
Electric And Magnetic Fields
1. Keep cables close together by twisting or taping them, or using a
cable cover.
Welding current, as it flows through welding cables, will cause electromagnetic fields. There has been and still is some concern about such
fields. However, after examining more than 500 studies spanning 17
years of research, a special blue ribbon committee of the National
Research Council concluded that: “The body of evidence, in the
committee’s judgment, has not demonstrated that exposure to powerfrequency electric and magnetic fields is a human-health hazard.”
However, studies are still going forth and evidence continues to be
examined. Until the final conclusions of the research are reached, you
may wish to minimize your exposure to electromagnetic fields when
welding or cutting.
2. Arrange cables to one side and away from the operator.
To reduce magnetic fields in the workplace, use the following
procedures:
OM-2232 Page 4
3. Do not coil or drape cables around your body.
4. Keep welding power source and cables as far away from operator as practical.
5. Connect work clamp to workpiece as close to the weld as possible.
About Implanted Medical Devices:
Implanted Medical Device wearers should consult their doctor and the
device manufacturer before performing or going near arc welding, spot
welding, gouging, plasma arc cutting, or induction heating operations.
If cleared by your doctor, then following the above procedures is recommended.
SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION
fre_som_2007−04
7
Se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes.
2-1. Symboles utilisés
DANGER! − Indique une situation dangereuse qui si on
l’évite pas peut donner la mort ou des blessures graves.
Les dangers possibles sont montrés par les symboles
joints ou sont expliqués dans le texte.
Indique une situation dangereuse qui si on l’évite pas
peut donner la mort ou des blessures graves. Les dangers possibles sont montrés par les symboles joints ou
sont expliqués dans le texte.
NOTE − Indique des déclarations pas en relation avec des blessures
personnelles.
. Indique des instructions spécifiques.
Ce groupe de symboles veut dire Avertissement! Attention! DANGER
DE CHOC ELECTRIQUE, PIECES EN MOUVEMENT, et PIECES
CHAUDES. Consulter les symboles et les instructions ci-dessous y
afférant pour les actions nécessaires afin d’éviter le danger.
2-2. Dangers relatifs au soudage à l’arc
Les symboles représentés ci-dessous sont utilisés dans ce manuel pour attirer l’attention et identifier les dangers possibles. En
présence de l’un de ces symboles, prendre garde et suivre les
instructions afférentes pour éviter tout risque. Les instructions
en matière de sécurité indiquées ci-dessous ne constituent
qu’un sommaire des instructions de sécurité plus complètes
fournies dans les normes de sécurité énumérées dans la Section 2-5. Lire et observer toutes les normes de sécurité.
Seul un personnel qualifié est autorisé à installer, faire fonctionner, entretenir et réparer cet appareil.
D
D
D
Pendant le fonctionnement, maintenir à distance toutes les
personnes, notamment les enfants de l’appareil.
UNE DÉCHARGE ÉLECTRIQUE peut
entraîner la mort.
Le contact d’organes électriques sous tension peut
provoquer des accidents mortels ou des brûlures
graves. Le circuit de l’électrode et de la pièce est
sous tension lorsque le courant est délivré à la
sortie. Le circuit d’alimentation et les circuits internes de la machine
sont également sous tension lorsque l’alimentation est sur Marche.
Dans le mode de soudage avec du fil, le fil, le dérouleur, le bloc de
commande du rouleau et toutes les parties métalliques en contact
avec le fil sont sous tension électrique. Un équipement installé ou mis
à la terre de manière incorrecte ou impropre constitue un danger.
D
D
(à fil), 2) un poste à souder DC manuel (électrode) ou 3) un poste à
souder AC à tension à vide réduite. Dans la plupart des situations,
l’utilisation d’un poste à souder DC à fil à tension constante est recommandée. En outre, ne pas travailler seul !
Couper l’alimentation ou arrêter le moteur avant de procéder à l’installation, à la réparation ou à l’entretien de l’appareil. Déverrouiller
l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de sécurité).
Installer le poste correctement et le mettre à la terre convenablement selon les consignes du manuel de l’opérateur et les normes
nationales, provinciales et locales.
Toujours vérifier la terre du cordon d’alimentation. Vérifier et
s’assurer que le fil de terre du cordon d’alimentation est bien
raccordé à la borne de terre du sectionneur ou que la fiche du
cordon est raccordée à une prise correctement mise à la terre.
En effectuant les raccordements d’entrée, fixer d’abord le conducteur de mise à la terre approprié et contre-vérifier les connexions.
Les câbles doivent être exempts d’humidité, d’huile et de graisse;
protégez−les contre les étincelles et les pièces métalliques
chaudes.
D Vérifier fréquemment le cordon d’alimentation afin de s’assurer
qu’il n’est pas altéré ou à nu, le remplacer immédiatement s’il l’est.
Un fil à nu peut entraîner la mort.
D Ne pas toucher aux pièces électriques sous tension.
D L’équipement doit être hors tension lorsqu’il n’est pas utilisé.
D Ne pas utiliser des câbles usés, endommagés, de grosseur insuffisante ou mal épissés.
D Ne pas enrouler les câbles autour du corps.
D Porter des gants isolants et des vêtements de protection secs et
sans trous.
D Si la pièce soudée doit être mise à la terre, le faire directement
avec un câble distinct.
D S’isoler de la pièce à couper et du sol en utilisant des housses ou
des tapis assez grands afin d’éviter tout contact physique avec la
pièce à couper ou le sol.
D Ne pas toucher l’électrode quand on est en contact avec la pièce,
la terre ou une électrode provenant d’une autre machine.
D Ne pas se servir de source électrique à courant électrique dans les
zones humides, dans les endroits confinés ou là où on risque de
tomber.
D Se servir d’une source électrique à courant électrique UNIQUEMENT si le procédé de soudage le demande.
D Si l’utilisation d’une source électrique à courant électrique s’avère
nécessaire, se servir de la fonction de télécommande si l’appareil
en est équipé.
D D’autres consignes de sécurité sont nécessaires dans les conditions suivantes : risques électriques dans un environnement
humide ou si l’on porte des vêtements mouillés ; sur des structures
métalliques telles que sols, grilles ou échafaudages ; en position
coincée comme assise, à genoux ou couchée ; ou s’il y a un risque
élevé de contact inévitable ou accidentel avec la pièce à souder ou
le sol. Dans ces conditions, utiliser les équipements suivants,
dans l’ordre indiqué : 1) un poste à souder DC à tension constante
D Ne pas toucher des porte électrodes connectés à deux machines
en même temps à cause de la présence d’une tension à vide doublée.
D N’utiliser qu’un matériel en bon état. Réparer ou remplacer sur-lechamp les pièces endommagées. Entretenir l’appareil
conformément à ce manuel.
D Porter un harnais de sécurité si l’on doit travailler au-dessus du sol.
D S’assurer que tous les panneaux et couvercles sont correctement
en place.
D Fixer le câble de retour de façon à obtenir un bon contact métalmétal avec la pièce à souder ou la table de travail, le plus près
possible de la soudure.
D Isoler la pince de masse quand pas mis à la pièce pour éviter le
contact avec tout objet métallique.
D Ne pas raccorder plus d’une électrode ou plus d’un câble de
masse à une même borne de sortie de soudage.
OM-2232 Page 5
Il reste une TENSION DC NON NÉGLIGEABLE dans
les sources de soudage onduleur quand on a
coupé l’alimentation.
D Arrêter les convertisseurs, débrancher le courant électrique et
décharger les condensateurs d’alimentation selon les instructions
indiquées dans la partie Entretien avant de toucher les pièces.
DES PIÈCES CHAUDES peuvent
provoquer des brûlures graves.
D Ne pas toucher à mains nues les parties
chaudes.
D Prévoir une période de refroidissement avant de
travailler à l’équipement.
D Ne pas toucher aux pièces chaudes, utiliser les outils recommandés et porter des gants de soudage et des vêtements épais pour
éviter les brûlures.
LE SOUDAGE peut provoquer un in
cendie ou une explosion.
Le soudage effectué sur des conteneurs fermés tel
que des réservoirs, tambours ou des conduites peu
provoquer leur éclatement. Des étincelles peuven
être projetées de l’arc de soudure. La projection d’étincelles, des pièce
chaudes et des équipements chauds peut provoquer des incendies e
des brûlures. Le contact accidentel de l’électrode avec des objet
métalliques peut provoquer des étincelles, une explosion, un surchauf
fement ou un incendie. Avant de commencer le soudage, vérifier e
s’assurer que l’endroit ne présente pas de danger.
D Déplacer toutes les substances inflammables à une distance de
10,7 m de l’arc de soudage. En cas d’impossibilité les recouvrir
soigneusement avec des protections homologués.
D Ne pas souder dans un endroit là où des étincelles peuvent tomber
sur des substances inflammables.
LES FUMÉES ET LES GAZ peuvent être
dangereux.
D Se protéger et d’autres personnes de la projection d’étincelles et
de métal chaud.
Le soudage génère des fumées et des gaz. Leur
inhalation peut être dangereux pour votre santé.
D Des étincelles et des matériaux chauds du soudage peuvent
facilement passer dans d’autres zones en traversant de petites
fissures et des ouvertures.
D Eloigner votre tête des fumées. Ne pas respirer les fumées.
D Surveiller tout déclenchement d’incendie et tenir un extincteur à
proximité.
D À l’intérieur, ventiler la zone et/ou utiliser une ventilation forcée au
niveau de l’arc pour l’évacuation des fumées et des gaz de soudage.
D Le soudage effectué sur un plafond, plancher, paroi ou séparation
peut déclencher un incendie de l’autre côté.
D Si la ventilation est médiocre, porter un respirateur anti-vapeurs
approuvé.
D Ne pas effectuer le soudage sur des conteneurs fermés tels que
des réservoirs, tambours, ou conduites, à moins qu’ils n’aient été
préparés correctement conformément à AWS F4.1 (voir les normes de sécurité).
D Lire et comprendre les spécifications de sécurité des matériaux
(MSDS) et les instructions du fabricant concernant les métaux, les
consommables, les revêtements, les nettoyants et les dégraisseurs.
D Ne soudez pas si l’air ambiant est chargé de particules, gaz, ou vapeurs inflammables (vapeur d’essence, par exemple).
D Travailler dans un espace fermé seulement s’il est bien ventilé ou
en portant un respirateur à alimentation d’air. Demander toujours à
un surveillant dûment formé de se tenir à proximité. Des fumées et
des gaz de soudage peuvent déplacer l’air et abaisser le niveau
d’oxygène provoquant des blessures ou des accidents mortels.
S’assurer que l’air de respiration ne présente aucun danger.
D Brancher le câble de masse sur la pièce le plus près possible de la
zone de soudage pour éviter le transport du courant sur une
longue distance par des chemins inconnus éventuels en provoquant des risques d’électrocution, d’étincelles et d’incendie.
D Ne pas souder dans des endroits situés à proximité d’opérations
de dégraissage, de nettoyage ou de pulvérisation. La chaleur et
les rayons de l’arc peuvent réagir en présence de vapeurs et former des gaz hautement toxiques et irritants.
D En cas de non utilisation, enlever la baguette d’électrode du porteélectrode ou couper le fil à la pointe de contact.
D Ne pas souder des métaux munis d’un revêtement, tels que l’acier
galvanisé, plaqué en plomb ou au cadmium à moins que le revêtement n’ait été enlevé dans la zone de soudure, que l’endroit soit
bien ventilé, et en portant un respirateur à alimentation d’air. Les
revêtements et tous les métaux renfermant ces éléments peuvent
dégager des fumées toxiques en cas de soudage.
LES RAYONS DE L’ARC peuvent pro
voquer des brûlures dans les yeux e
sur la peau.
Le rayonnement de l’arc du procédé de soudage
génère des rayons visibles et invisibles intense
(ultraviolets et infrarouges) susceptibles de provoquer des brûlure
dans les yeux et sur la peau. Des étincelles sont projetées pendant le
soudage.
D Porter un casque de soudage approuvé muni de verres filtrants
approprié pour protéger visage et yeux pendant le soudage
(voir ANSI Z49.1 et Z87.1 énuméré dans les normes de sécurité).
D Porter des lunettes de sécurité avec écrans latéraux même sous
votre casque.
D Avoir recours à des écrans protecteurs ou à des rideaux pour
protéger les autres contre les rayonnements les éblouissements
et les étincelles ; prévenir toute personne sur les lieux de ne pas
regarder l’arc.
D Porter des vêtements confectionnés avec des matières résistantes et ignifuges (cuir, coton lourd ou laine) et des bottes de
protection.
OM-2232 Page 6
D Ne pas utiliser le poste de soudage pour dégeler des conduites gelées.
D Porter des vêtements de protection dépourvus d’huile tels que des
gants en cuir, une chemise en matériau lourd, des pantalons sans
revers, des chaussures hautes et un couvre chef.
D Avant de souder, retirer toute substance combustible de vos poches telles qu’un allumeur au butane ou des allumettes.
D Une fois le travail achevé, assurez−vous qu’il ne reste aucune
trace d’étincelles incandescentes ni de flammes.
D Utiliser exclusivement des fusibles ou coupe−circuits appropriés.
Ne pas augmenter leur puissance; ne pas les ponter.
D Une fois le travail achevé, assurez−vous qu’il ne reste aucune
trace d’étincelles incandescentes ni de flammes.
D Utiliser exclusivement des fusibles ou coupe−circuits appropriés.
Ne pas augmenter leur puissance; ne pas les ponter.
D Suivre les recommandations dans OSHA 1910.252(a)(2)(iv) et
NFPA 51B pour les travaux à chaud et avoir de la surveillance et un
extincteur à proximité.
DES PIECES DE METAL ou DES SALETES peuvent provoquer des blessures dans les yeux.
D Le soudage, l’écaillement, le passage de la pièce à la brosse en
fil de fer, et le meulage génèrent des étincelles et des particules
métalliques volantes. Pendant la période de refroidissement des
soudures, elles risquent de projeter du laitier.
D Porter des lunettes de sécurité avec écrans latéraux ou un écran
facial.
LES ACCUMULATIONS DE GAZ
risquent de provoquer des blessures
ou même la mort.
D Protéger les bouteilles de gaz comprimé d’une chaleur excessive,
des chocs mécaniques, des dommages physiques, du laitier, des
flammes ouvertes, des étincelles et des arcs.
D Fermer l’alimentation du gaz protecteur en cas
de non-utilisation.
D Veiller toujours à bien aérer les espaces confinés ou se servir d’un respirateur d’adduction
d’air homologué.
D Placer les bouteilles debout en les fixant dans un support stationnaire ou dans un porte-bouteilles pour les empêcher de tomber ou
de se renverser.
LES CHAMPS MAGNETIQUES peuvent affecter des implants médicaux.
D Porteur de simulateur cardiaque ou autre implants médicaux, rester à distance.
D Les porteurs d’implants doivent d’abord consulter leur médecin
avant de s’approcher des opérations de soudage à l’arc, de soudage par points, de gougeage, du coupage plasma ou de chauffage par induction.
D Tenir les bouteilles éloignées des circuits de soudage ou autres
circuits électriques.
D Ne jamais placer une torche de soudage sur une bouteille à gaz.
D Une électrode de soudage ne doit jamais entrer en contact avec
une bouteille.
D Ne jamais souder une bouteille pressurisée − risque d’explosion.
LE BRUIT peut endommager l’ouïe.
D Utiliser seulement des bouteilles de gaz protecteur, régulateurs,
tuyaux et raccords convenables pour cette application spécifique ;
les maintenir ainsi que les éléments associés en bon état.
Le bruit des processus et des équipements peut
affecter l’ouïe.
D Détourner votre visage du détendeur-régulateur lorsque vous
ouvrez la soupape de la bouteille.
D Porter des protections approuvées pour les
oreilles si le niveau sonore est trop élevé.
D Le couvercle du détendeur doit toujours être en place, sauf lorsque
la bouteille est utilisée ou qu’elle est reliée pour usage ultérieur.
LES BOUTEILLES peuvent exploser
si elles sont endommagées.
D Utiliser les équipements corrects, les bonnes procédures et suffisamment de personnes pour soulever et déplacer les bouteilles.
Des bouteilles de gaz protecteur contiennent du gaz
sous haute pression. Si une bouteille est endommagée, elle peut exploser. Du fait que les bouteilles de
gaz font normalement partie du procédé de soudage, les manipuler avec précaution.
D Lire et suivre les instructions sur les bouteilles de gaz comprimé,
l’équipement connexe et le dépliant P-1 de la CGA (Compressed
Gas Association) mentionné dans les principales normes de sécurité.
2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance
Risque D’INCENDIE OU D’EXPLOSION.
D Ne pas placer l’appareil sur, au-dessus ou
à proximité de surfaces inflammables.
D Ne pas installer l’appareil à proximité de produits inflammables.
D Ne pas surcharger l’installation électrique − s’assurer que
l’alimentation est correctement dimensionnée et protégée avant
de mettre l’appareil en service.
LA CHUTE DE L’APPAREIL peut
blesser.
D Utiliser l’anneau de levage uniquement pour
soulever l’appareil, NON PAS les chariots, les
bouteilles de gaz ou tout autre accessoire.
D Utiliser un équipement de levage de capacité
suffisante pour lever l’appareil.
D En utilisant des fourches de levage pour déplacer l’unité, s’assurer que les fourches sont suffisamment longues pour dépasser
du côté opposé de l’appareil.
L’EMPLOI EXCESSIF peut
CHAUFFER L’ÉQUIPEMENT.
LES ÉTINCELLES VOLANTES risquent de provoquer des blessures.
D Porter un écran facial pour protéger le visage et
les yeux.
D Affûter l’électrode au tungstène uniquement à la
meuleuse dotée de protecteurs. Cette manœuvre est à exécuter dans un endroit sûr lorsque l’on
porte l’équipement homologué de protection du
visage, des mains et du corps.
D Les étincelles risquent de causer un incendie − éloigner toute substance inflammable.
LES CHARGES ÉLECTROSTATIQUES peuvent endommager les
circuits imprimés.
D Établir la connexion avec la barrette de terre
avant de manipuler des cartes ou des pièces.
D Utiliser des pochettes et des boîtes antistatiques pour stocker, déplacer ou expédier des
cartes de circuits imprimes.
SUR-
D Prévoir une période de refroidissement ; respecter le cycle opératoire nominal.
D Réduire le courant ou le facteur de marche
avant de poursuivre le soudage.
D Ne pas obstruer les passages d’air du poste.
DES ORGANES MOBILES peuvent
provoquer des blessures.
D Ne pas s’approcher des organes mobiles.
D Ne pas s’approcher des points de coincement
tels que des rouleaux de commande.
OM-2232 Page 7
LES FILS DE SOUDAGE peuvent
provoquer des blessures.
LE RAYONNEMENT HAUTE FRÉQUENCE (H.F.) risque de provoquer
des interférences.
D Ne pas appuyer sur la gâchette avant d’en
avoir reçu l’instruction.
D Ne pas diriger le pistolet vers soi, d’autres personnes ou toute pièce mécanique en engageant le fil de soudage.
DES ORGANES MOBILES peuvent
provoquer des blessures.
D S’abstenir de toucher des organes mobiles tels
que des ventilateurs.
D Maintenir fermés et verrouillés les portes, panneaux, recouvrements et dispositifs de protection.
D Seules des personnes qualifiées sont autorisées à enlever les
portes, panneaux, recouvrements ou dispositifs de protection
pour l’entretien.
D Remettre les portes, panneaux, recouvrements ou dispositifs de
protection quand l’entretien est terminé et avant de rebrancher
l’alimentation électrique.
LIRE LES INSTRUCTIONS.
D Le rayonnement haute fréquence (H.F.) peut
provoquer des interférences avec les équipements de radio−navigation et de communication, les services de sécurité et les ordinateurs.
D Demander seulement à des personnes qualifiées familiarisées
avec des équipements électroniques de faire fonctionner l’installation.
D L’utilisateur est tenu de faire corriger rapidement par un électricien
qualifié les interférences résultant de l’installation.
D Si le FCC signale des interférences, arrêter immédiatement l’appareil.
LE SOUDAGE À L’ARC risque de
provoquer des interférences.
D
D
D Lisez le manuel d’instructions avant l’utilisation
ou la maintenance de l’appareil.
D N’utiliser que les pièces de rechange recommandées par le constructeur.
D
D Effectuer régulièrement le contrôle et l’entretien de l’installation.
D
D Maintenir soigneusement fermés les portes et les panneaux des
sources de haute fréquence, maintenir les éclateurs à une distance correcte et utiliser une terre et un blindage pour réduire les
interférences éventuelles.
D
D L’énergie électromagnétique risque de provoquer des interférences pour l’équipement électronique sensible tel que les ordinateurs et l’équipement commandé par ordinateur tel que
les robots.
Veiller à ce que tout l’équipement de la zone de soudage soit
compatible électromagnétiquement.
Pour réduire la possibilité d’interférence, maintenir les câbles de
soudage aussi courts que possible, les grouper, et les poser
aussi bas que possible (ex. par terre).
Veiller à souder à une distance de 100 mètres de tout équipement électronique sensible.
Veiller à ce que ce poste de soudage soit posé et mis à la terre
conformément à ce mode d’emploi.
En cas d’interférences après avoir pris les mesures précédentes, il incombe à l’utilisateur de prendre des mesures supplémentaires telles que le déplacement du poste, l’utilisation de câbles blindés, l’utilisation de filtres de ligne ou la pose de protecteurs dans la zone de travail.
2-4. Proposition californienne 65 Avertissements
Les équipements de soudage et de coupage produisent des
fumées et des gaz qui contiennent des produits chimiques
dont l’État de Californie reconnaît qu’ils provoquent des malformations congénitales et, dans certains cas, des cancers.
(Code de santé et de sécurité de Californie, chapitre 25249.5
et suivants)
Les batteries, les bornes et autres accessoires contiennent
du plomb et des composés à base de plomb, produits chimiques dont l’État de Californie reconnaît qu’ils provoquent des
cancers et des malformations congénitales ou autres
problèmes de procréation. Se laver les mains après manipulation.
OM-2232 Page 8
Pour les moteurs à essence :
Les gaz d’échappement des moteurs contiennent des produits chimiques dont l’État de Californie reconnaît qu’ils
provoquent des cancers et des malformations congénitales
ou autres problèmes de procréation.
Pour les moteurs diesel :
Les gaz d’échappement des moteurs diesel et certains de
leurs composants sont reconnus par l’État de Californie comme provoquant des cancers et des malformations
congénitales ou autres problèmes de procréation.
2-5. Principales normes de sécurité
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
de Global Engineering Documents (téléphone : 1-877-413-5184, site
Internet : www.global.ihs.com).
Recommended Safe Practices for the Preparation for Welding and Cutting of Containers and Piping, American Welding Society Standard
AWS F4.1 de Global Engineering Documents (téléphone :
1-877-413-5184, site Internet : www.global.ihs.com).
National Electrical Code, NFPA Standard 70, de National Fire Protection Association, P.O. Box 9101, Quincy, MA 02269-9101 (téléphone :
617-770-3000, site Internet : www.nfpa.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
de Compressed Gas Association, 4221 Walney Road, 5th Floor, Chantilly, VA 20151 (téléphone : 703-788-2700, site Internet :
www.cganet.com).
Code for Safety in Welding and Cutting, CSA Standard W117.2, de
Canadian Standards Association, 5060 Mississauga, Ontario, Canada
L4W 5NS (téléphone : 800-463-6727 ou à Toronto 416-747-4044, site
Internet : www.csa-international.org).
Safe Practice For Occupational And Educational Eye And Face Protection, ANSI Standard Z87.1, de American National Standards Institute,
11 West 43rd Street, New York, NY 10036-8002 (téléphone :
212-642-4900, site Internet : www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, de National Fire Protection Association,
P.O. Box 9101, Quincy, MA 02269-9101 (téléphone : 617-770-3000,
site Internet : www.nfpa.org).
OSHA, Occupational Safety and Health Standards for General Industry, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,
and Part 1926, Subpart J, de U.S. Government Printing Office, Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954
(téléphone : 1-866-512-1800) (il y a 10 bureaux régionaux−−le téléphone de la région 5, Chicago, est 312-353-2220, site Internet :
www.osha.gov).
2-6. Information EMF
Considérations sur le soudage et les effets de basse fréquence et des
champs magnétiques et électriques.
Le courant de soudage, pendant son passage dans les câbles de soudage, causera des champs électromagnétiques. Il y a eu et il y a encore
un certain souci à propos de tels champs. Cependant, après avoir examiné plus de 500 études qui ont été faites pendant une période de
recherche de 17 ans, un comité spécial ruban bleu du National
Research Council a conclu : « L’accumulation de preuves, suivant le
jugement du comité, n’a pas démontré que l’exposition aux champs
magnétiques et champs électriques à haute fréquence représente un
risque à la santé humaine ». Toutefois, des études sont toujours en
cours et les preuves continuent à être examinées. En attendant que les
conclusions finales de la recherche soient établies, il vous serait
souhaitable de réduire votre exposition aux champs électromagnétiques pendant le soudage ou le coupage.
Pour réduire les champs magnétiques sur le poste de travail, appliquer
les procédures suivantes :
1. Garder les câbles ensemble, les torsader, les scotcher, ou les
recouvrir d’une housse.
2. Disposer les câbles d’un côté et à distance de l’opérateur.
3. Ne pas courber pas et ne pas entourer pas les câbles autour de
votre corps.
4. Garder le poste de soudage et les câbles le plus loin possible de
vous.
5. Connecter la pince sur la pièce aussi près que possible de la
soudure.
En ce qui concerne les implants médicaux :
Les porteurs d’implants doivent d’abord consulter leur médecin avant
de s’approcher des opérations de soudage à l’arc, de soudage par
points, de gougeage, du coupage plasma ou de chauffage par induction. Si le médecin approuve, il est recommandé de suivre les
procédures précédentes.
OM-2232 Page 9
OM-2232 Page 10
SECTION 3 − INSTALLATION
. Unless otherwise noted, the Invision 456P is shown throughout this manual. When information does not apply to both models, the applicable model
is specified.
3-1. Specifications
Input
Power
Rated Welding
Output
Three
Phase
450 A @ 38 Volts DC,
100% Duty Cycle;
565 A @ 43 Volts DC,
60% Duty Cycle
Amperage
Range
(XMT 456
CC/CV
Only)
Voltage
Range
5 − 600
10 − 38
Maximum
OpenCircuit
Voltage
DC
Amperes Input At Rated
Load Output 60 Hz,
Three-Phase
95
KVA
KW
230 V
460 V
575 V
230/460
575
230/460
575
50.8
(0.14*)
27.8
(0.09*)
24.4
(0.12*)
21.2
(0.06*)
24.3
(0.12*)
19.2
(0.04*)
19.0
(0.07*)
*While idling
3-2. Duty Cycle and Overheating
Duty Cycle is percentage of 10 minutes that unit can weld at rated load
without overheating.
If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
duty cycle before welding.
NOTICE − Exceeding duty cycle
can damage unit and void warranty.
100% Duty Cycle At 450 Amperes
60% Duty Cycle At 565 Amperes
6 Minutes Welding
Continuous Welding
Overheating
4 Minutes Resting
A/V
0
15
Minutes
OR
Reduce Duty Cycle
duty1 4/95 − SA-181 560
OM-2232 Page 11
3-3. Volt-Ampere Curves
Volt-ampere curves show minimum
and maximum voltage and amperage output capabilities of unit.
Curves of other settings fall between curves shown.
Invision 456P and XMT 456 (CV Only)
XMT 456 (CC Only)
va_curve1 4/95 − SA-181 561 / SA-181 562
3-4. Dimensions And Weight
Hole Layout Dimensions
A
A
14-21/64 in (363.9 mm)
B
20-3/4 in (527.1 mm)
C
23-27/64 in (594.9 mm)
D
24-31/32 in (634.2 mm)
28 in
(711 mm)
D
E
12-3/8 in (314.3 mm)
F
9/32 in (7.1 mm) Dia.
C
18 in
(457 mm)
B
15-1/2
/ in
(394 mm)
Weight
118 lb (53.5 kg)
OM-2232 Page 12
F
E
3-5. Selecting a Location
2
Movement
Tipping
!
Do not move or operate
unit where it could tip.
3
OR
1
1
Location
Lifting Forks
Use lifting forks to move unit.
Extend forks beyond opposite side
of unit.
5
2
Lifting Handles
Use handles to lift unit.
3
Hand Cart
Use cart or similar device to move
unit.
18 in
(460 mm)
4
4
Rating Label
Use rating label to determine input
power needs.
5
Line Disconnect Device
Locate unit near correct input
power supply.
!
18 in
(460 mm)
Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
loc_2 3/96 - Ref. ST-151 556 / ST-800 611 / ST-801 718
OM-2232 Page 13
3-6. Weld Output Terminals And Selecting Cable Sizes
!
ARC WELDING can cause Electromagnetic Interference.
To reduce possible interference, keep weld cables as short as possible, close together, and down low, such as on the floor.
Locate welding operation 100 meters from any sensitive electronic equipment. Be sure this welding machine is installed
and grounded according to this manual. If interference still occurs, the user must take extra measures such as moving
the welding machine, using shielded cables, using line filters, or shielding the work area.
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit
Not Exceeding***
Weld Output
Terminals
!
!
Turn off power before
connecting to weld output terminals.
100 ft (30 m) or Less
Do not use worn, damaged, undersized, or
poorly spliced cables.
Positive
(+)
* This
Negative
( )
(−)
150 ft
(45 m)
200 ft
(60 m)
250 ft
(70 m)
300 ft
(90 m)
350 ft
400 ft
(105 m) (120 m)
100
4 (20)
4 (20)
4 (20)
3 (30)
2 (35)
1 (50)
1/0 (60)
1/0 (60)
150
3 (30)
3 (30)
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
3/0 (95)
200
3 (30)
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
4/0 (120)
250
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 2/0
(2x70)
300
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 3/0
(2x95)
350
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
400
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
2 ea. 4/0
(2x120)
500
2/0 (70)
3/0 (95)
4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
3 ea. 3/0
(3x95)
3 ea. 3/0
(3x95)
600
3/0 (95)
4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
3 ea. 3/0
(3x95)
3 ea. 4/0
(3x120)
3 ea. 4/0
(3x120)
chart is a general guideline and may not suit all applications. If cable overheats, use next size larger cable.
**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
( ) = mm2 for metric use
***For distances longer than those shown in this guide, call a factory applications representative at 920-735-4505.
OM-2232 Page 14
S-0007-F−
3-7. Connecting Weld Output Cables
1
4
Do not place
anything between
weld cable terminal
and copper bar.
2
Tools Needed:
3
3/4 in (19 mm)
Incorrect Installation
!
Turn off power before connecting to
weld output terminals.
!
Failure to properly connect weld
cables may cause excessive heat
and start a fire, or damage your machine.
1 Weld Output Terminal
2 Supplied Weld Output Terminal Nut
3 Weld Cable Terminal
4 Copper Bar
Remove supplied nut from weld output terminal. Slide weld cable terminal onto weld
803 778-B
output terminal and secure with nut so that
weld cable terminal is tight against copper
bar. Do not place anything between weld
cable terminal and copper bar. Make
sure that the surfaces of the weld cable
terminal and copper bar are clean.
3-8. Remote 14 Receptacle Information
Socket*
24 VOLTS AC
A
B
K
J
115 VOLTS AC
I
H
C L N
D M
G
E F
Ref. ST-801 718
REMOTE
CONTROL
A/V
AMPERAGE
VOLTAGE
GND
Socket Information
A
24 volts ac. Protected by circuit breaker CB2.
B
Contact closure to A completes 24 volts ac contactor control circuit.
I
115 volts ac. Protected by circuit breaker CB1.
J
Contact closure to I completes 115 volts ac contactor control circuit.
C
Output to remote control; +10 volts dc in MIG
mode. For XMT 456 only: 0 to +10 volts dc in other modes.
D
Remote control circuit common.
E
0 to +10 volts dc input command signal from remote control.
M
Mode select.
N
Remote inductance control.
F
Current feedback; +1 volt dc per 100 amperes.
H
Voltage feedback; +1 volt dc per 10 arc volts.
G
Circuit common for 24 and 115 volts ac circuits.
K
Chassis common.
*The remaining sockets are not used.
OM-2232 Page 15
3-9. 115 Volts AC Duplex Receptacle And Circuit Breakers
1
115 V 10 A AC Receptacle
Power is shared between duplex
receptacle and Remote 14 receptacle (see Section 3-8).
2
3
1
2
3
Circuit Breaker CB1
Circuit Breaker CB2
CB1 protects duplex receptacle
and 115 volts ac portion of Remote
14 receptacle from overload.
CB2 protects 24 volts ac portion of
Remote 14 receptacle from
overload.
Press button to reset breaker.
ST-801 524-B
3-10. Electrical Service Guide
NOTICE − INCORRECT INPUT POWER can damage this welding power source. This welding power source requires a CONTINUOUS supply of
input power at rated frequency(+10%) and voltage (+10%). Phase to ground voltage shall not exceed +10% of rated input voltage. Do not use a generator with automatic idle device (that idles engine when no load is sensed) to supply input power to this welding power source.
NOTICE − Actual input voltage should not be 10% less than minimum and/or 10% more than maximum input voltages listed in table. If actual input
voltage is outside this range, output may not be be available.
Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommendations are for a dedicated branch circuit sized for the rated output and duty cycle of the welding power source.
60 Hz Three Phase
Input Voltage
230
460
575
Input Amperes At Rated Output
53
27
24
60
30
30
80
40
35
8
10
12
102
(31)
269
(82)
254
(77)
8
10
12
Max Recommended Standard Fuse Rating In Amperes
1
Time-Delay 2
Normal Operating
3
Min Input Conductor Size In AWG 4
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG 4
Reference: 2005 National Electrical Code (NEC) (including article 630)
1 Consult factory for circuit breaker applications.
2 “Time-Delay” fuses are UL class “RK5” .
3 “Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.
OM-2232 Page 16
3-11. Selecting Input Voltage (230/460 Volt Models Only)
!
. Be sure to reinstall all four screws
securing relinking board in place.
Turn Off welding power
source, disconnect input
power, and check voltage
on input capacitors according to Section 5-3 before
proceeding.
Check input voltage available at
site.
1
1
Voltage Selection View
Window
Check voltage selected in unit.
Changing selection is only necessary if selected value does not
match available input voltage.
2
3
4
5
Relinking Board PC6
Mounting Screws
Receptacle RC8 (Connection
For 230 VAC Input Power)
Receptacle RC7 (Connection
For 460 VAC Input Power)
Move relinking board as needed
and connect plug PLG4 (in unit) to
RC8 or RC7 according to input
power voltage.
2
3
4
3
5
Tools Needed:
5/16 in
ST-801 718 / ST-801 536-B
OM-2232 Page 17
3-12. Connecting Input Power
!
Turn Off welding power
source, and check voltage
on input capacitors according to Sections 5-3 or
5-4, as applicable, before
proceeding.
1
Strain Relief Connector Clamp
Obtain and install proper connector.
2
3
Input And Grounding
Conductors
Contactor W1
Select size and length using Section 3-10. Connect as shown in
illustration.
For 230/460 Volt Models With
Optional
Ground
Current
Sensor:
L1 L2 L3
4
3
1
Ground Current Sensor
When cutting input and ground conductors to length, ground conductor
must be 26 inches (660 mm) long to
wrap around ground current sensor. Note that ground conductor
must be insulated between strain
relief and ground terminal.
2
5
Connections For
Standard Models
L1
L2
4
L3
Insert input and grounding conductors through strain relief. Route
grounding conductor through reed
switch from right side of unit, under
switch, and through reed switch
again (two turns total) before connecting to ground terminal.
For All Models:
5
Line Disconnect Device
See Section 3-10.
Reinstall right side panel.
Or
= GND/PE
!
1
Always connect grounding
conductor first.
2
Tools Needed:
3
L1
L2
L3
Connections For 230/460 Volt
Models With Optional Ground
Current Sensor
OM-2232 Page 18
5/16 in
801 535-B / 801 822-A
SECTION 4 − OPERATION
4-1. Front Panel Controls For Invision 456P
1
Power Switch
. The
fan motor is thermostatically
controlled and only runs when cooling is
needed.
2
3
Voltmeter (see Section 4-3)
Ammeter (see Section 4-3)
4 Voltage Adjustment Control
5 Inductance Control
Inductance determines the “wetness” of the
weld puddle. When set higher, “wetness”
(puddle fluidity) increases.
6 Remote On/Off Receptacle (An Option
On 230/460 Volt Models)
1
2
Sockets 1 and 2 are connected in parallel with
the Power switch. For remote On/Off control,
connect a suitable plug from a remote switch
to the receptacle and place front panel Power
switch in Off position. Unit can then be turned
On and Off through the use of the remote
switch.
3
4
6
5
ST-180 311-C
4-2. Mode and Voltage Control For Invision 456P
1
Remote 14 Receptacle
Mode Control
The unit defaults to standard MIG
mode. When a suitable external
pulsing control is attached to the
Remote 14 receptacle, the remote
pendant controls whether the unit is
in standard MIG or pulsed MIG
mode. When the pulsing control is
disconnected, the unit returns to
standard MIG operation.
Voltage Control
The unit defaults to Panel control of
output voltage. When a suitable remote voltage control or pulsing control is attached to the Remote 14 receptacle, the remote device assumes control of output voltage.
1
To return to Panel control of voltage,
disconnect or disable any remote
devices that send an input to pin E.
ST-801 192
OM-2232 Page 19
4-3. Meter Functions For Invision 456P
. The meters display the actual weld output values for approximately three seconds after the arc is broken.
Meter Reading At Idle
Mode
V
Meter Reading While Welding
A
V
24.5
250
Preset Volts
Blank
Actual Volts
Actual Amps
V
A
V
A
24.5
MIG
Pulsed
MIG
A
PPP
PPP
24.5
250
Pulse Display
Pulse Display
Actual Volts
Actual Amps
4-4. Front Panel Controls For XMT 456 CC/CV
1
Power Switch
. The
fan motor is thermostatically
controlled and only runs when cooling is
needed.
2 Voltmeter (see Section 4-5)
3 Ammeter (see Section 4-5)
4 V/A (Voltage/Amperage) Adjust Control
5 Voltage/Amperage Control Switch
For front panel control, place switch in Panel
position and use the V/A Adjust control.
For remote control, make connections to Remote 14 receptacle, and place switch in Remote position. In most modes, remote control
is a percent of the V/A Adjust control setting.
Value selected on V/A Adjust is maximum
available on remote. In the MIG mode, remote
control provides full range of unit output regardless of V/A Adjust control setting.
6 Mode Switch
The Mode switch setting determines both the
process and output On/Off control (see Section 4-6). Source of control (panel or remote)
for the amount of output is selected on the V/A
Control switch.
Control adjusts inductance when MIG position is selected on the Mode switch. Inductance determines the “wetness” of the weld
puddle. When set towards maximum, “wetness” (puddle fluidity) increases.
For Air Carbon Arc (CAC-A) cutting and gouging, place switch in the Stick position. For best
results, place Inductance/Dig control in the
maximum position.
7
When Pulsed MIG, or one of the TIG modes
is selected, this control is not functional.
Inductance/Dig Control
Control adjusts Dig when the Stick or CC
mode is selected on the Mode switch. When
set towards minimum, short-circuit amperage
at low arc voltage is the same as normal welding amperage.
8
2
7
Remote On/Off Receptacle (An Option
On 230/460 Volt Models)
Sockets 1 and 2 are connected in parallel with
the Power switch. For remote On/Off control,
connect a suitable plug from a remote switch
to the receptacle and place front panel Power
switch in Off position. Unit can then be turned
On and Off through the use of the remote
switch.
When set towards maximum, short-circuit
amperage is increased at low arc voltage to
assist with arc starts as well as reduce sticking while welding (see volt-ampere curves in
Section 3-3).
1
8
Select setting best suited for application.
3
6
4
5
196 446
OM-2232 Page 20
4-5. Meter Functions For XMT 456 CC/CV
. The meters display the actual weld output values for approximately three seconds after the arc is broken.
Meter Reading At Idle
Mode
V
Scratch
Start TIG
Lift-Arc TIG
Meter Reading While Welding
A
80.0
85
Actual Volts
Actual Amps
V
A
V
A
7.0
85
85
Preset Amps
Actual Volts
Actual Amps
V
A
V
A
Blank
Preset Amps
Actual Volts
Actual Amps
V
A
V
A
24.5
250
Preset Volts
Blank
Actual Volts
Actual Amps
V
A
V
A
10.3
85
PPP
PPP
24.5
250
Pulse Display
Pulse Display
Actual Volts
Actual Amps
V
A
V
A
Blank
Preset Amps
Actual Volts
Actual Amps
V
A
V
A
85
CC
80.0
V-Sense
Feeder
10.3
Actual Volts
24.5
Stick
85
Preset Amps
85
Pulsed
MIG
10.3
A
Actual Volts (OCV)
TIG
MIG
V
85
24.5
24.5
85
85
Actual Volts (OCV)
Preset Amps
Actual Volts
Actual Amps
V
A
V
A
24.5
250
Actual Volts
Actual Amps
80.0
Flashes OCV And Preset
Blank
4-6. Mode Switch Settings For XMT 456 CC/CV
. The Stick and CC modes provide the Adaptive Hot Start™ feature, which automatically increases the output amperage at the start of a weld should
the start require it. This eliminates electrode sticking at arc start.
Mode Switch Setting
Process
Output On/Off Control
Scratch Start TIG
GTAW
Electrode Hot
Lift-Arc TIG
GTAW − See Section 4-7
Electrode Hot
TIG
GTAW With HF Unit, Pulsing Device, Or Remote Control
At Remote 14
MIG
GMAW
At Remote 14
Pulsed MIG
GMAW-P (Requires an external pulsing device.)
At Remote 14
CC
Stick (SMAW) With Remote On/Off
At Remote 14
Stick
SMAW
Electrode Hot
V-Sense Feeder
MIG (GMAW) With Voltage Sensing Wire Feeder
Electrode Hot
OM-2232 Page 21
4-7. Lift-Arc TIG Procedure For XMT 456 CC/CV
With Mode switch in the Lift-Arc TIG
position, start an arc as follows:
1
“Touch”
1−2
Seconds
2
1
TIG Electrode
2
Workpiece
Touch tungsten electrode to workpiece at weld start point, hold
electrode to workpiece for 1-2
seconds, and slowly lift electrode.
An arc will form when electrode is
lifted.
Normal open-circuit voltage is not
present before tungsten electrode
touches workpiece; only a low
sensing voltage is present between
electrode and workpiece. The
solid-state output contactor does
not energize until after electrode is
touching workpiece. This allows
electrode to touch workpiece without overheating, sticking, or getting
contaminated.
Do NOT Strike Like A Match!
Ref. S-156 279
OM-2232 Page 22
SECTION 5 − MAINTENANCE AND TROUBLESHOOTING
5-1. Routine Maintenance
!
Disconnect power
before maintaining.
. Maintain more often
during severe conditions.
3 Months
Replace
damaged or
unreadable
label.
Repair or
replace
cracked
cables.
Replace
cracked
torch body.
Repair or
replace cracked
cables and cords.
6 Months
Clean and
tighten weld
terminals.
Blow out
inside.
5-2. Blowing Out Inside of Unit
!
Do not remove case when
blowing out inside of unit.
To blow out unit, direct airflow
through front and back louvers as
shown.
ST-801 718
OM-2232 Page 23
5-3. Removing Right Side Panel and Measuring Input Capacitor Voltage In 230/460 Volt
Models
!
Significant DC voltage can remain on capacitors after unit is Off. Always check the voltage as shown to be sure the input capacitors
have discharged before working on unit.
Turn Off welding power source, and
disconnect input power.
1
Right Side Panel
To remove panel, remove screws
securing panel to unit.
2
Relinking Board PC6
3
Voltmeter
Measure the dc voltage across the
screw terminals on PC6 as shown
until voltage drops to near 0 (zero)
volts.
Proceed with job inside unit. Reinstall right side panel when finished.
1
2
3
230 VAC input:
+ lead to lower
terminal, − lead to
upper terminal
2
3
460 VAC input:
+ lead to lower right
terminal, − lead to
upper left terminal
Tools Needed:
5/16 in
ST-801 718 / ST-801 536-B
OM-2232 Page 24
5-4. Removing Right Side Panel and Measuring Input Capacitor Voltage in 575 Volt
Models
!
Significant DC voltage can remain on capacitors after unit is Off. Always check the voltage as shown to be sure the input capacitors
have discharged before working on unit.
Turn Off welding power source, and
disconnect input power.
1
Right Side Panel
To remove panel, remove screws
securing panel to unit.
2
Interconnect Board PC2
3
Voltmeter
Measure the dc voltage across the
screw terminals on PC2 as shown
until voltage drops to near 0 (zero)
volts.
Proceed with job inside unit. Reinstall right side panel when finished.
1
2
3
+ lead to lower right
terminal, − lead to
upper right terminal
Tools Needed:
5/16 in
Ref. ST-801 718 / Ref. ST-801 536-A
OM-2232 Page 25
5-5. Voltmeter/Ammeter Help Displays
1
2
3
4
5
V
A
HE.L
P−0
V
A
HE.L
P−1
V
A
HE.L
P−2
V
A
HE.L
P−3
V
A
HE.L
P−4
. All directions are in reference to the front
of the unit. All circuitry referred to is located inside the unit.
1
Help 0 Display
6
7
8
9
10
V
A
HE.L
P−5
V
A
HE.L
P−6
V
A
HE.L
P−7
V
A
HE.L
P−8
V
A
HE.L
P−9
fan to cool it (see Section 3-2). Operation will
continue when the unit has cooled.
5
Help 4 Display
Indicates a shorted thermistor RT2 on the left
side of the unit. If this display is shown, contact a Factory Authorized Service Agent.
Indicates a malfunction in the thermal
protection circuitry located on the right side
of the unit. If this display is shown, contact a
Factory Authorized Service Agent.
2
6
Help 1 Display
Indicates a malfunction in the primary power
circuit. If this display is shown, contact a Factory Authorized Service Agent.
3
Help 2 Display
Indicates a malfunction in the thermal
protection circuitry located on the left side of
the unit. If this display is shown, contact a
Factory Authorized Service Agent.
4
Help 3 Display
Indicates the left side of the unit has overheated. The unit has shut down to allow the
OM-2232 Page 26
Help 5 Display
Indicates the right side of the unit has overheated. The unit has shut down to allow the
fan to cool it (see Section 3-2). Operation will
continue when the unit has cooled.
7
Help 6 Display
Indicates that the input voltage is too low and
the unit has automatically shut down. Operation will continue when the voltage is within
±15% of the operating range. If this display
is shown, have an electrician check the input
voltage.
8
Help 7 Display
Indicates that the input voltage is too high
and the unit has automatically shut down.
Operation will continue when the voltage is
within ±15% of the operating range. If this
display is shown, have an electrician check
the input voltage.
9 Help 8 Display
Indicates a malfunction in the secondary
power circuit of the unit. If this display is
shown, contact a Factory Authorized Service Agent. In addition, when the optional
ground current sensor is installed, this display indicates weld current in the ground
conductor. When this occurs, have an electrician check the primary and secondary
connections.
10 Help 9 Display
Indicates a shorted thermistor RT1 on the
right side of the unit. If this display is shown,
contact a Factory Authorized Service Agent.
5-6. Troubleshooting
Trouble
No weld output; unit completely inoperative.
Remedy
Place line disconnect switch in On position (see Section 3-12).
Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section 3-12).
Check for proper input power connections (see Section 3-12).
No weld output; meter display On.
Check, repair, or replace remote control.
Unit overheated. Allow unit to cool with fan On (see Section 3-2).
Check voltmeter/ammeter Help displays.
Erratic or improper weld output.
Use proper size and type of weld cable (see Section 3-10).
Clean and tighten all weld connections.
No 115 volts ac output at duplex
receptacle, Remote 14 receptacle.
Reset circuit breaker CB1 (see Section 3-9).
No 24 volts ac output at Remote 14 receptacle.
Reset circuit breaker CB2 (see Section 3-9).
OM-2232 Page 27
SECTION 6 − ELECTRICAL DIAGRAM
Figure 6-1. Circuit Diagram For Welding Power Sources (230/460 Volt Models)
OM-2232 Page 28
Ref. 181 412-E
OM-2232 Page 29
Figure 6-2. Circuit Diagram For Welding Power Sources (575 Volt Models)
OM-2232 Page 30
186 987-B
OM-2232 Page 31
SECTION 7 − PARTS LIST
. Hardware is
23
common and
not available unless listed.
24
25
20
26
19
22
18
27
17
21
28
16
4
29
15
PC2
14
8
10
9
30
13
31
12
32
33
PC1
11
7
34
38
39 40 41
42
35
36
37
6
4
5
3
61
4
62 60
69
2
45
43 44
63
46
59
64
57
58
56
47
1
66
65
68
67
48
55
54
53
Figure 7-1. Complete Assembly
OM-2232 Page 32
49
52
45
51
50
801 715-H
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 7-1. Complete Assembly
. . . 1 . . . . . . . . . . . . . . . . 187 234
. . . 2 . . . . . . . . . . . . . . . . 195 585
. . . 3 . . . . . . . . . . . . . . +190 270
. . . 3 . . . . . . . . . . . . . . +190 373
. . . . . . . . . . . . . . . . . . . . . . 178 551
. . . 4 . . . . . . . . . . . . . . . . 185 835
. . . 5 . . . . . T1 . . . . . . . 179 933
. . . 5 . . . . . T1 . . . . . . . 186 984
. . . 6 . . . . FM2 . . . . . . 183 918
. . . 7 . . . . PC1 . . . . . . 223 865
. . . 7 . . . . PC1 . . . . . . 225 688
. . . 8 . . . . . . . . . . . . . . . . 194 371
. . . 9 . . . . . . . . . . . . . . . . 194 450
. . . 10 . . . . C3-6 . . . . . . 192 935
. . . 10 . . . . C3-6 . . . . . . 206 757
. . . . . . . . . . . . . . . . . . . . . . 193 738
. . . . . . . . . . . . . . . . . . . . . . 217 040
. . . 11 . . . . . . . . . . . . . . . . 181 925
. . . 12 . . . . . Z1 . . . . . . . 180 029
. . . 13 . . . . . L1 . . . . . . . 180 026
. . . 14 . . . . . T2 . . . . . . . 183 192
. . . 14 . . . . . T2 . . . . . . . 185 232
. . . 15 . . . . . . . . . . . . . . . . 180 105
. . . 16 . . . . CB2 . . . . . . 093 995
. . . 17 . . . . CB1 . . . . . . 083 432
. . . 18 . . . . RC2 . . . . . . 604 176
. . . 19 . . . . . . . . . . . . . . . . 179 847
. . . . . . . . . . . . . . . . . . . . . . 217 297
. . . 20 . . . . . . . . . . . . . . +179 899
. . . . . . . . . . . . . . . . . . . . . . 181 181
. . . 21 . . . . . . . . . . . . . . . . 153 403
. . . 22 . . . . . . . . . . . . . . . . 025 248
. . . 23 . . . . . W1 . . . . . . . 180 270
. . . 24 . . . . C1,2 . . . . . . 186 015
. . . 24 . . . . C1,2 . . . . . . 230 272
. . . 24 . . . . C1,2 . . . . . . 230 270
. . . 25 . . . . . . . . . . . . . . . . 185 992
. . . 26 . . . . CT1 . . . . . . 181 271
. . . 27 . . . . . . . . . . . . . . . . 177 547
. . . 28 . . . . PC6 . . . . . . 180 131
. . . 29 . . . . PC2 . . . . . . 187 243
. . . 29 . . . . PC2 . . . . . . 187 244
. . . . . . . . . . . . . . . . . . . . . . 185 214
. . . 30 . . . . . . . . . . . . . . . . 179 276
. . . 31 . . . . . . . . . . . . . . +194 449
. . . 32 . . . . SR1 . . . . . . 184 260
. . . 33 . . . PM1,2 . . . . . 235 309
. . . 34 . . . . RT1,2 . . . . . 173 632
. . . 35 . . . . . . . . . . . . . . . . 179 930
. . . 36 . . . . . . . . . . . . . . . . 204 165
. . . 37 . . . . . W2 . . . . . ♦180 270
. . . 38 . . . . . . . . . . . . . . . . 190 272
. . . 39 . . . . . . . . . . . . . . . . 224 853
. . . 40 . . . . . . . . . . . . . . . . 182 654
. . . 41 . . . . L3,4 . . . . . . 180 103
. . . 42 . . . . . . . . . . . . . . . . 176 844
. . . 43 . . . . PC3 . . . . . . 221 854
. . . . . . . . . . . . . . . . . . . . . . 190 380
. . . Cover, Top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Panel, Side Rh (230/460) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Panel, Side Rh (575) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Insulator, Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Label, Warning Electric Shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Transformer, HF (230/460) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Transformer, HF (575) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Motor, Fan 24VDC 3000RPM 43CFM W/10 Ohm Resistor . . . . . . . . . .
. . . Circuit Card Assembly, Control (230/460) . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Circuit Card Assembly, Control (575) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Spacer, Al 3.500 Lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Bracket, Mtg Capacitor/Pc Board/Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Capacitor, Elctlt 2700Uf 420 (230/460) . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Kit, Capacitor Elctlt Replacement (Includes) . . . . . . . . . . . . . . . . . . . . . .
. . . . Capacitor, Elctlt 1800 UF 500 VDC (575) . . . . . . . . . . . . . . . . . . . . . . .
. . . . Nut, Nylon M12 Thread Capacitor Mounting . . . . . . . . . . . . . . . . . . . .
. . . Insulator, Stabilizer Lead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Stabilizer, Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Inductor, Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Transformer, Control 230/460VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Transformer, Control 575VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Bracket, Mtg Transformer Aux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Circuit Breaker, Man Reset 15A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Circuit Breaker, Man Reset 10A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Receptacle, Str Dx Grd 3W 15A 120V . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Plate, Identification (Order By Model & Serial Number) . . . . . . . . . . . . .
. . . Cover, Receptacle Weatherproof Duplex Rcpt . . . . . . . . . . . . . . . . . . . . .
. . . Panel, Rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Label, Warning Electric Shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Bushing, Snap-In Nyl .750 Id X 1.000Mtg Hole . . . . . . . . . . . . . . . . . . . .
. . . Stand-Off, Insul .250−20 X 1.250 Lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Contactor, Def Prp 40A 3P 24VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Capacitor, Polyp Film .34Uf 1000VAC (230/460) (Invision 456) . . . . . .
. . . Capacitor, Polyp Film .34Uf 1000 VRMS 10% (230/460) (XMT 456) . .
. . . Capacitor, Polyp Film .22Uf 1000 VRMS 10% (575) . . . . . . . . . . . . . . . .
. . . Bus Bar, Capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Transformer, Current 500 Turns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Bushing, Snap-In Nyl Ct−Mt 1.125Mtg Hole . . . . . . . . . . . . . . . . . . . . . . .
. . . Circuit Card Assembly, Relink (230/460 Only) . . . . . . . . . . . . . . . . . . . . .
. . . Circuit Card Assembly, Interconnect (230/460) . . . . . . . . . . . . . . . . . . . .
. . . Circuit Card Assembly, Interconnect (575) . . . . . . . . . . . . . . . . . . . . . . . .
. . . Bus Bar, Interconnecting (575 Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Bushing, Snap-In Nyl 1.000 X 1.375Mtg Hole . . . . . . . . . . . . . . . . . . . . .
. . . Windtunnel, Rh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Kit, Diode Power Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Kit, Transistor IGBT Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Thermistor, NTC 30K Ohm @ 25Deg C . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Heat Sink, Power Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Heat Sink, Rect Quad Diode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Contactor, Def Prp 40A 3P 24VAC (230/460 Only) . . . . . . . . . . . . . . . . .
. . . Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Bracket, Mtg Choke . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Gasket, Di−Dt Rubber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Coil, Di−Dt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Core, Ferrite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . Circuit Card Assembly, Front Panel (Invision 456) . . . . . . . . . . . . . . . . .
. . . . Assy, Socket/7 Segment Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
2
1
1
1
3
1
1
1
1
1
1
1
4
1
4
4
1
1
1
1
1
1
1
1
1
1
1
1
1
2
4
1
2
2
2
2
1
1
1
1
1
2
1
1
1
1
2
1
1
1
1
1
1
2
2
1
1
OM-2232 Page 33
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 7-1. Complete Assembly (Continued)
. . . 43 . . . . PC3 . . . . . . 220 644 . . . Circuit Card Assembly, Front Panel (XMT 456) . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . 190 380 . . . . Assy, Socket/7 Segment Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 44 . . . . . . . . . . . . . . . . 182 707 . . . Terminal, Power Output Black . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 45 . . . . C7,8 . . . . . . 222 488 . . . Capacitor Assy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 46 . . . . RC1 . . . . . . 143 976 . . . Receptacle W/Sockets, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 47 . . . . . . . . . . . . . . . . 180 732 . . . Boot, Neg Output Stud . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 48 . . . . . . . . . . . . . . . . 179 898 . . . Panel, Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 49 . . . . . . . . . . . . . . . . 179 848 . . . Boot, Pos Output Stud . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 50 . . . . . . . . . . . . . . . . 174 991 . . . Knob, Pointer 1.250 Dia X .250 Id (Xmt 456) (230/460 Only) . . . . . . . .
. . . 51 . . . . . . . . . . . . . . . . 181 245 . . . Terminal, Power Output Red . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 52 . . . . RC3 . . . . ♦186 487 . . . Conn, Circ CPC W/Terminals (230/460 Only) . . . . . . . . . . . . . . . . . . . . .
. . . 53 . . . . . S1 . . . . . . . 128 756 . . . Switch, Tgl 3PST 40A 600VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . 176 226 . . . Insulator, Switch Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 54 . . . . . . . . . . . . . . . . . . . . . . . . . . . Nameplate, (Order By Model And Serial Number) . . . . . . . . . . . . . . . . . .
. . . 55 . . . . HD1 . . . . . . 168 829 . . . Transducer, Current 1000A Max . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 56 . . . . . . . . . . . . . . . . 174 992 . . . Knob, Pointer .840 Dia X .250 Id (Invision 456) . . . . . . . . . . . . . . . . . . . .
. . . 56 . . . . . . . . . . . . . . . . 174 992 . . . Knob, Pointer .840 Dia X .250 Id (Xmt 456) . . . . . . . . . . . . . . . . . . . . . . .
. . . 57 . . . . . . . . . . . . . . . . 179 851 . . . Knob, Pointer 1.670 Dia X .250 Id . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 58 . . . . . . . . . . . . . . . . 179 928 . . . Shroud, Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 59 . . . . FM1 . . . . . . 175 084 . . . Motor, Fan 24VDC 3000RPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 60 . . . . . T3 . . . . . ♦181 042 . . . Transformer (230/460 Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 61 . . . . R1,2
....
C9,10,11,12 . . . 175 194 . . . Resistor/Capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 62 . . . . D1-4 . . . . . . 201 531 . . . Kit, Diode Ultra Fast Recovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 63 . . . . . . . . . . . . . . . . 179 826 . . . Insulator, Rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 64 . . . . . . . . . . . . . . +179 902 . . . Windtunnel, Lh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . 179 276 . . . Bushing, Snap-In Nyl 1.000 X 1.375Mtg Hole . . . . . . . . . . . . . . . . . . . . .
. . . 65 . . . . . . . . . . . . . . . . 183 827 . . . Bus Bar, Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 66 . . . . . . . . . . . . . . . . 134 327 . . . Label, Warning General Precautionary . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 67 . . . . . . . . . . . . . . . . 222 317 . . . Label, Warning Match Input Power (230/460 Only) . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG4 . . . . . . 131 056 . . . Housing Receptacle & Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . RC10 . . . . . . 166 679 . . . Housing Receptacle Pins & Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG2 . . . . . . 115 092 . . . Housing Plug & Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . PLG7,19 . . . . 115 094 . . . Housing Plug & Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . PLG9,11 . . . . 115 091 . . . Housing Plug & Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . ♦143 976 . . . Receptacle W/Sockets (230/460 Only) . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . ♦135 409 . . . Housing Plug & Pins (230/460 Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . PLG3,12 . . . . 180 776 . . . Plug, W/Leads Voltage Feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . PLG5,15,16 . . . 175 026 . . . Plug, W/Leads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . PLG21 . . . . . 211 138 . . . Plug, W/Leads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . ♦172 565 . . . Cable, Power 21 In 18Ga (230/460 Only) . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . ♦185 373 . . . Switch, Reed (230/460 Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 68 . . . . . . . . . . . . . . . . 190 271 . . . Panel, Side Lh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 69 . . . . . . . . . . . . . . . . 199 840 . . . Bus Bar, Diode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
2
4
1
1
2
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
♦OPTIONAL
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-2232 Page 34
Effective January 1, 2007
(Equipment with a serial number preface of “LH” or newer)
Warranty Questions?
Call
1-800-4-A-MILLER
for your local
Miller distributor.
Your distributor also gives
you ...
Service
You always get the fast,
reliable response you
need. Most replacement
parts can be in your
hands in 24 hours.
Support
Need fast answers to the
tough welding questions?
Contact your distributor.
The expertise of the
distributor and Miller is
there to help you, every
step of the way.
This limited warranty supersedes all previous Miller warranties and is exclusive with no other
guarantees or warranties expressed or implied.
LIMITED WARRANTY − Subject to the terms and conditions
* Induction Heating Coils and Blankets, Cables, and
below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants to
Non-Electronic Controls
its original retail purchaser that new Miller equipment sold after
* APT & SAF Model Plasma Cutting Torches
the effective date of this limited warranty is free of defects in
* Remote Controls
material and workmanship at the time it is shipped by Miller. THIS
WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER
* Accessory (Kits)
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE
* Replacement Parts (No labor)
WARRANTIES OF MERCHANTABILITY AND FITNESS.
* Spoolmate Spoolguns
Within the warranty periods listed below, Miller will repair or
* Canvas Covers
replace any warranted parts or components that fail due to such
defects in material or workmanship. Miller must be notified in
writing within thirty (30) days of such defect or failure, at which
time Miller will provide instructions on the warranty claim
procedures to be followed.
Miller shall honor warranty claims on warranted equipment listed
below in the event of such a failure within the warranty time
periods. All warranty time periods start on the delivery date of the
equipment to the original end-user purchaser, and not to exceed
one year after the equipment is shipped to a North American
distributor or eighteen months after the equipment is shipped to
an International distributor.
1.
5 Years Parts — 3 Years Labor
2.
3 Years — Parts and Labor
*
*
*
*
*
*
*
*
*
3.
Original main power rectifiers
Transformer/Rectifier Power Sources
Plasma Arc Cutting Power Sources
Process Controllers
Semi-Automatic and Automatic Wire Feeders
Inverter Power Sources (Unless Otherwise Stated)
Water Coolant Systems (Integrated)
Intellitig
Engine Driven Welding Generators
(NOTE: Engines are warranted separately by the
engine manufacturer.)
1 Year — Parts and Labor Unless Specified
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
Motor Driven Guns (w/exception of Spoolmate
Spoolguns)
Positioners and Controllers
Automatic Motion Devices
RFCS Foot Controls
Induction Heating Power Sources, Coolers, and
Electronic
Controls/Recorders
Water Coolant Systems (Non-Integrated)
Flowgauge and Flowmeter Regulators (No Labor)
HF Units
Grids
Spot Welders
Load Banks
Arc Stud Power Sources & Arc Stud Guns
Racks
Running Gear/Trailers
Plasma Cutting Torches (except APT & SAF
Models)
Field Options
(NOTE: Field options are covered under True Blue®
for the remaining warranty period of the product they
are installed in, or for a minimum of one year —
whichever is greater.)
Bernard-Branded Mig Guns (No Labor)
Weldcraft-Branded TIG Torches (No Labor)
Subarc Wire Drive Assemblies
4.
6 Months — Batteries
5.
90 Days — Parts
*
MIG Guns/TIG Torches and Subarc (SAW) Guns
Miller’s True Blue® Limited Warranty shall not apply to:
1.
Consumable components; such as contact tips,
cutting nozzles, contactors, brushes, slip rings, relays
or parts that fail due to normal wear. (Exception:
brushes, slip rings, and relays are covered on Bobcat,
Trailblazer, and Legend models.)
2.
Items furnished by Miller, but manufactured by others, such
as engines or trade accessories. These items are covered
by the manufacturer’s warranty, if any.
3.
Equipment that has been modified by any party other than
Miller, or equipment that has been improperly installed,
improperly operated or misused based upon industry
standards, or equipment which has not had reasonable and
necessary maintenance, or equipment which has been
used for operation outside of the specifications for the
equipment.
MILLER PRODUCTS ARE INTENDED FOR PURCHASE AND
USE BY COMMERCIAL/INDUSTRIAL USERS AND PERSONS
TRAINED AND EXPERIENCED IN THE USE AND
MAINTENANCE OF WELDING EQUIPMENT.
In the event of a warranty claim covered by this warranty, the
exclusive remedies shall be, at Miller’s option: (1) repair; or (2)
replacement; or, where authorized in writing by Miller in
appropriate cases, (3) the reasonable cost of repair or
replacement at an authorized Miller service station; or (4)
payment of or credit for the purchase price (less reasonable
depreciation based upon actual use) upon return of the goods at
customer’s risk and expense. Miller’s option of repair or
replacement will be F.O.B., Factory at Appleton, Wisconsin, or
F.O.B. at a Miller authorized service facility as determined by
Miller. Therefore no compensation or reimbursement for
transportation costs of any kind will be allowed.
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR
DIRECT,
INDIRECT,
SPECIAL,
INCIDENTAL
OR
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF
PROFIT), WHETHER BASED ON CONTRACT, TORT OR ANY
OTHER LEGAL THEORY.
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND
ANY
IMPLIED
WARRANTY,
GUARANTY
OR
REPRESENTATION AS TO PERFORMANCE, AND ANY
REMEDY FOR BREACH OF CONTRACT TORT OR ANY
OTHER LEGAL THEORY WHICH, BUT FOR THIS
PROVISION, MIGHT ARISE BY IMPLICATION, OPERATION
OF LAW, CUSTOM OF TRADE OR COURSE OF DEALING,
INCLUDING
ANY
IMPLIED
WARRANTY
OF
MERCHANTABILITY OR FITNESS FOR PARTICULAR
PURPOSE, WITH RESPECT TO ANY AND ALL EQUIPMENT
FURNISHED BY MILLER IS EXCLUDED AND DISCLAIMED
BY MILLER.
Some states in the U.S.A. do not allow limitations of how long an
implied warranty lasts, or the exclusion of incidental, indirect,
special or consequential damages, so the above limitation or
exclusion may not apply to you. This warranty provides specific
legal rights, and other rights may be available, but may vary from
state to state.
In Canada, legislation in some provinces provides for certain
additional warranties or remedies other than as stated herein,
and to the extent that they may not be waived, the limitations and
exclusions set out above may not apply. This Limited Warranty
provides specific legal rights, and other rights may be available,
but may vary from province to province.
miller_warr 2007−01
Owner’s Record
Please complete and retain with your personal records.
Model Name
Serial/Style Number
Purchase Date
(Date which equipment was delivered to original customer.)
Distributor
Address
City
State
Zip
For Service
Contact a DISTRIBUTOR or SERVICE AGENCY near you.
Always provide Model Name and Serial/Style Number.
Contact your Distributor for:
Welding Supplies and Consumables
Options and Accessories
Personal Safety Equipment
Service and Repair
Miller Electric Mfg. Co.
Replacement Parts
Training (Schools, Videos, Books)
Technical Manuals (Servicing Information
and Parts)
Circuit Diagrams
Welding Process Handbooks
To locate a Distributor or Service Agency visit
www.millerwelds.com or call 1-800-4-A-Miller
Contact the Delivering Carrier to:
File a claim for loss or damage during
shipment.
For assistance in filing or settling claims, contact
your distributor and/or equipment manufacturer’s
Transportation Department.
PRINTED IN USA
© 2007 Miller Electric Mfg. Co. 2007−01
An Illinois Tool Works Company
1635 West Spencer Street
Appleton, WI 54914 USA
International Headquarters−USA
USA Phone: 920-735-4505 Auto-Attended
USA & Canada FAX: 920-735-4134
International FAX: 920-735-4125
European Headquarters −
United Kingdom
Phone: 44 (0) 1204-593493
FAX: 44 (0) 1204-598066
www.MillerWelds.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising