Miller | KJ300965 | Owner Manual | Miller MILLERMATIC VINTAGE User manual

Miller MILLERMATIC VINTAGE User manual
OM-1311
153 490P
January 1999
Processes
MIG (GMAW) Welding
Flux Cored (FCAW) Welding
Description
Arc Welding Power Source And
Wire Feeder
R
Millermatic Vintage
And M-25 Gun
Visit our website at
www.MillerWelds.com
From Miller to You
Thank you and congratulations on choosing Miller. Now
you can get the job done and get it done right. We know
you don’t have time to do it any other way.
That’s why when Niels Miller first started building arc
welders in 1929, he made sure his products offered
long-lasting value and superior quality. Like you, his
customers couldn’t afford anything less. Miller products
had to be more than the best they could be. They had to
be the best you could buy.
Today, the people that build and sell Miller products continue the
tradition. They’re just as committed to providing equipment and service
that meets the high standards of quality and value established in 1929.
This Owner’s Manual is designed to help you get the most out of your
Miller products. Please take time to read the Safety precautions. They will
help you protect yourself against potential hazards on the worksite. We’ve
made installation and operation quick and easy.
With Miller you can count on years of reliable
service with proper maintenance. And if for
some reason the unit needs repair, there’s a
Troubleshooting section that will help you
Miller is the first welding figure out what the problem is. The parts list
equipment manufacturer in will then help you to decide which exact part
the U.S.A. to be registered
you may need to fix the problem. Warranty and
to the ISO 9001 Quality
service information for your particular model
System Standard.
are also provided.
Miller Electric manufactures a full line
of welders and welding related equipment.
For information on other quality Miller
products, contact your local Miller distributor
to receive the latest full line catalog or
individual catalog sheets. To locate your nearest
distributor call 1-800-4-A-Miller.
Working as hard as you
do − every power source
from Miller is backed by
the most hassle-free warranty in the business.
Miller offers a Technical
Manual which provides
more detailed service and
parts information for your
unit. To obtain a Technical
Manual, contact your local
distributor. Your distributor
can also supply you with
Welding Process Manuals
such as SMAW, GTAW,
GMAW, and GMAW-P.
TABLE OF CONTENTS
The following terms are
used interchangeably
throughout this manual:
MIG = GMAW
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Additional Symbols for Installation, Operation, and Maintenance . . . . . . . . . . . . . . . . . . . . . .
1-4. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 1 − CONSIGNES DE SECURITE − LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . .
1-1. Signification des symboles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Dangers relatifs au soudage à l’arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement
et la maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. Information sur les champs électromagnétiques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 − INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2. Volt-Ampere Curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3. Duty Cycle And Overheating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-4. Installing Work Clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-5. Installing Gas Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-6. Installing Welding Gun . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-7. Installing Wire Spool And Adjusting Hub Tension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-8. Setting Gun Polarity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-9. Positioning Jumper Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-10. Electrical Service Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-11. Selecting A Location And Connecting Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-12. Threading Welding Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 − OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1. Front Panel Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2. Center Baffle Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 4 − MAINTENANCE & TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. Circuit Breaker CB1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3. Fuses F1 And F2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-4. Changing Drive Roll And Wire Inlet Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-5. Replacing Gun Contact Tip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-6. Unicable Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-7. Cleaning Or Replacing Gun Liner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-8. Replacing Switch And/Or Head Tube . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-9. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 5 − ELECTRICAL DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 − PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPTIONS AND ACCESSORIES
WARRANTY
1
1
1
3
3
4
5
5
5
7
8
8
9
9
9
10
11
11
12
12
13
13
14
14
15
16
16
16
17
17
17
18
18
18
18
19
20
21
22
24
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING
som _nd_5/97
1-1. Symbol Usage
Means Warning! Watch Out! There are possible hazards
with this procedure! The possible hazards are shown in
the adjoining symbols.
Y Marks a special safety message.
. Means “Note”; not safety related.
This group of symbols means Warning! Watch Out! possible
ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.
Consult symbols and related instructions below for necessary actions
to avoid the hazards.
1-2. Arc Welding Hazards
Y The symbols shown below are used throughout this manual to
call attention to and identify possible hazards. When you see
the symbol, watch out, and follow the related instructions to
avoid the hazard. The safety information given below is only
a summary of the more complete safety information found in
the Safety Standards listed in Section 1-4. Read and follow all
Safety Standards.
D If earth grounding of the workpiece is required, ground it directly
with a separate cable − do not use work clamp or work cable.
Y Only qualified persons should install, operate, maintain, and
repair this unit.
D Wear a safety harness if working above floor level.
D Keep all panels and covers securely in place.
Y During operation, keep everybody, especially children, away.
D Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shocks
or severe burns. The electrode and work circuit is
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also
live when power is on. In semiautomatic or automatic wire welding, the
wire, wire reel, drive roll housing, and all metal parts touching the
welding wire are electrically live. Incorrectly installed or improperly
grounded equipment is a hazard.
D Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
D Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
D Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
D Do not connect more than one electrode or work cable to any
single weld output terminal.
SIGNIFICANT DC VOLTAGE exists after removal of
input power on inverters.
D Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section
before touching any parts.
D Do not touch live electrical parts.
D Wear dry, hole-free insulating gloves and body protection.
D Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.
D Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
D Use AC output ONLY if required for the welding process.
D If AC output is required, use remote output control if present on
unit.
D Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
D Properly install and ground this equipment according to its
Owner’s Manual and national, state, and local codes.
D Keep your head out of the fumes. Do not breathe the fumes.
D Always verify the supply ground − check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
grounded receptacle outlet.
D When making input connections, attach proper grounding conductor first − double-check connections.
D Frequently inspect input power cord for damage or bare wiring −
replace cord immediately if damaged − bare wiring can kill.
D Turn off all equipment when not in use.
D Do not use worn, damaged, undersized, or poorly spliced cables.
D Do not weld in locations near degreasing, cleaning, or spraying operations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.
D Do not drape cables over your body.
FUMES AND GASES can be hazardous.
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health.
D If inside, ventilate the area and/or use exhaust at the arc to remove
welding fumes and gases.
D If ventilation is poor, use an approved air-supplied respirator.
D Read the Material Safety Data Sheets (MSDSs) and the
manufacturer’s instructions for metals, consumables, coatings,
cleaners, and degreasers.
D Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watchperson nearby. Welding fumes and gases can displace air and
lower the oxygen level causing injury or death. Be sure the breathing air is safe.
D Do not weld on coated metals, such as galvanized, lead, or
cadmium plated steel, unless the coating is removed from the weld
area, the area is well ventilated, and if necessary, while wearing an
air-supplied respirator. The coatings and any metals containing
these elements can give off toxic fumes if welded.
OM-1311 Page 1
ARC RAYS can burn eyes and skin.
Arc rays from the welding process produce intense
visible and invisible (ultraviolet and infrared) rays
that can burn eyes and skin. Sparks fly off from the
weld.
D Wear a welding helmet fitted with a proper shade of filter to protect
your face and eyes when welding or watching (see ANSI Z49.1
and Z87.1 listed in Safety Standards).
D Wear approved safety glasses with side shields under your
helmet.
D Use protective screens or barriers to protect others from flash and
glare; warn others not to watch the arc.
D Wear protective clothing made from durable, flame-resistant material (leather and wool) and foot protection.
BUILDUP OF GAS can injure or kill.
D Shut off shielding gas supply when not in use.
D Always ventilate confined spaces or use
approved air-supplied respirator.
HOT PARTS can cause severe burns.
D Do not touch hot parts bare handed.
D Allow cooling period before working on gun or
torch.
MAGNETIC FIELDS can affect pacemakers.
WELDING can cause fire or explosion.
Welding on closed containers, such as tanks,
drums, or pipes, can cause them to blow up. Sparks
can fly off from the welding arc. The flying sparks, hot
workpiece, and hot equipment can cause fires and
burns. Accidental contact of electrode to metal objects can cause
sparks, explosion, overheating, or fire. Check and be sure the area is
safe before doing any welding.
D Protect yourself and others from flying sparks and hot metal.
D Do not weld where flying sparks can strike flammable material.
D Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
D Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
D Watch for fire, and keep a fire extinguisher nearby.
D Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
D Do not weld on closed containers such as tanks, drums, or pipes,
unless they are properly prepared according to AWS F4.1 (see
Safety Standards).
D Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly
unknown paths and causing electric shock and fire hazards.
D Do not use welder to thaw frozen pipes.
D Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
D Wear oil-free protective garments such as leather gloves, heavy
shirt, cuffless trousers, high shoes, and a cap.
D Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.
FLYING METAL can injure eyes.
D Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool,
they can throw off slag.
D Wear approved safety glasses with side
shields even under your welding helmet.
OM-1311 Page 2
D Pacemaker wearers keep away.
D Wearers should consult their doctor before
going near arc welding, gouging, or spot
welding operations.
NOISE can damage hearing.
Noise from some processes or equipment can
damage hearing.
D Wear approved ear protection if noise level is
high.
CYLINDERS can explode if damaged.
Shielding gas cylinders contain gas under high
pressure. If damaged, a cylinder can explode. Since
gas cylinders are normally part of the welding
process, be sure to treat them carefully.
D Protect compressed gas cylinders from excessive heat, mechanical shocks, slag, open flames, sparks, and arcs.
D Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
D Keep cylinders away from any welding or other electrical circuits.
D Never drape a welding torch over a gas cylinder.
D Never allow a welding electrode to touch any cylinder.
D Never weld on a pressurized cylinder − explosion will result.
D Use only correct shielding gas cylinders, regulators, hoses, and fittings designed for the specific application; maintain them and
associated parts in good condition.
D Turn face away from valve outlet when opening cylinder valve.
D Keep protective cap in place over valve except when cylinder is in
use or connected for use.
D Read and follow instructions on compressed gas cylinders,
associated equipment, and CGA publication P-1 listed in Safety
Standards.
1-3. Additional Symbols for Installation, Operation, and Maintenance
FIRE OR EXPLOSION hazard.
MOVING PARTS can cause injury.
D Do not install or place unit on, over, or near
combustible surfaces.
D Do not install unit near flammables.
D Do not overload building wiring − be sure power supply system is
properly sized, rated, and protected to handle this unit.
D Keep away from moving parts such as fans.
D Keep all doors, panels, covers, and guards
closed and securely in place.
FALLING UNIT can cause injury.
H.F. RADIATION can cause interference.
D Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
D Use equipment of adequate capacity to lift and
support unit.
D If using lift forks to move unit, be sure forks are
long enough to extend beyond opposite side of
unit.
D
OVERUSE can cause OVERHEATING
D
D Allow cooling period; follow rated duty cycle.
D Reduce current or reduce duty cycle before
starting to weld again.
D Do not block or filter airflow to unit.
D
D
D High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communications equipment.
D Have only qualified persons familiar with
electronic equipment perform this installation.
The user is responsible for having a qualified electrician promptly correct any interference problem resulting from the installation.
If notified by the FCC about interference, stop using the
equipment at once.
Have the installation regularly checked and maintained.
Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.
STATIC (ESD) can damage PC boards.
D Put on grounded wrist strap BEFORE handling
boards or parts.
D Use proper static-proof bags and boxes to
store, move, or ship PC boards.
ARC WELDING can cause interference.
MOVING PARTS can cause injury.
D Keep away from moving parts.
D Keep away from pinch points such as drive
rolls.
D
D
WELDING WIRE can cause injury.
D Do not press gun trigger until instructed to do
so.
D Do not point gun toward any part of the body,
other people, or any metal when threading
welding wire.
D
D
D Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.
D Be sure all equipment in the welding area is
electromagnetically compatible.
To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
Locate welding operation 100 meters from any sensitive electronic equipment.
Be sure this welding machine is installed and grounded
according to this manual.
If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables,
using line filters, or shielding the work area.
1-4. Principal Safety Standards
Safety in Welding and Cutting, ANSI Standard Z49.1, from American
Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126
Safety and Health Standards, OSHA 29 CFR 1910, from Superintendent of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Recommended Safe Practices for the Preparation for Welding and Cutting of Containers That Have Held Hazardous Substances, American
Welding Society Standard AWS F4.1, from American Welding Society,
550 N.W. LeJeune Rd, Miami, FL 33126
National Electrical Code, NFPA Standard 70, from National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
Code for Safety in Welding and Cutting, CSA Standard W117.2, from
Canadian Standards Association, Standards Sales, 178 Rexdale
Boulevard, Rexdale, Ontario, Canada M9W 1R3.
Safe Practices For Occupation And Educational Eye And Face
Protection, ANSI Standard Z87.1, from American National Standards
Institute, 1430 Broadway, New York, NY 10018.
Cutting And Welding Processes, NFPA Standard 51B, from National
Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
OM-1311 Page 3
1-5. EMF Information
Considerations About Welding And The Effects Of Low Frequency
Electric And Magnetic Fields
1. Keep cables close together by twisting or taping them.
Welding current, as it flows through welding cables, will cause electromagnetic fields. There has been and still is some concern about such
fields. However, after examining more than 500 studies spanning 17
years of research, a special blue ribbon committee of the National
Research Council concluded that: “The body of evidence, in the
committee’s judgment, has not demonstrated that exposure to powerfrequency electric and magnetic fields is a human-health hazard.”
However, studies are still going forth and evidence continues to be
examined. Until the final conclusions of the research are reached, you
may wish to minimize your exposure to electromagnetic fields when
welding or cutting.
2. Arrange cables to one side and away from the operator.
To reduce magnetic fields in the workplace, use the following
procedures:
Pacemaker wearers consult your doctor first. If cleared by your doctor,
then following the above procedures is recommended.
OM-1311 Page 4
3. Do not coil or drape cables around your body.
4. Keep welding power source and cables as far away from operator as practical.
5. Connect work clamp to workpiece as close to the weld as possible.
About Pacemakers:
SECTION 1 − CONSIGNES DE SECURITE − LIRE AVANT UTILISATION
som _nd_fre 5/97
1-1. Signification des symboles
Signifie Mise en garde ! Soyez vigilant ! Cette procédure
présente des risques de danger ! Ceux-ci sont identifiés
par des symboles adjacents aux directives.
Y Identifie un message de sécurité particulier.
. Signifie NOTA ; n’est pas relatif à la sécurité.
Ce groupe de symboles signifie Mise en garde ! Soyez vigilant ! Il y a des
risques de danger reliés aux CHOCS ÉLECTRIQUES, aux PIÈCES EN
MOUVEMENT et aux PIÈCES CHAUDES. Reportez-vous aux symboles
et aux directives ci-dessous afin de connaître les mesures à prendre pour
éviter tout danger.
1-2. Dangers relatifs au soudage à l’arc
Y Les symboles présentés ci-après sont utilisés tout au long du
présent manuel pour attirer votre attention et identifier les risques
de danger. Lorsque vous voyez un symbole, soyez vigilant et
suivez les directives mentionnées afin d’éviter tout danger. Les
consignes de sécurité présentées ci-après ne font que résumer
l’information contenue dans les normes de sécurité énumérées
à la section 1-4. Veuillez lire et respecter toutes ces normes de
sécurité.
D N’utiliser qu’un matériel en bon état. Réparer ou remplacer sur-lechamp les pièces endommagées. Entretenir l’appareil conformément
à ce manuel.
D Porter un harnais de sécurité quand on travaille en hauteur.
D Maintenir solidement en place tous les panneaux et capots.
Y L’installation, l’utilisation, l’entretien et les réparations ne doivent être confiés qu’à des personnes qualifiées.
D Fixer le câble de retour de façon à obtenir un bon contact métal-métal
avec la pièce à souder ou la table de travail, le plus près possible de la
soudure.
Y Au cours de l’utilisation, tenir toute personne à l’écart et plus particulièrement les enfants.
D
Isoler la pince de masse quand pas mis à la pièce pour éviter le contact
avec tout objet métallique.
UN CHOC ÉLECTRIQUE peut tuer.
Un simple contact avec des pièces électriques peut
provoquer une électrocution ou des blessures graves.
L’électrode et le circuit de soudage sont sous tension
dès que l’appareil est sur ON. Le circuit d’entrée et les
circuits internes de l’appareil sont également sous
tension à ce moment-là. En soudage semi-automatique ou automatique,
le fil, le dévidoir, le logement des galets d’entraînement et les pièces
métalliques en contact avec le fil de soudage sont sous tension. Des
matériels mal installés ou mal mis à la terre présentent un danger.
Il y a DU COURANT CONTINU IMPORTANT dans les
convertisseurs après la suppression de l’alimentation électrique.
D Arrêter les convertisseurs, débrancher le courant électrique, et décharger les condensateurs d’alimentation selon les instructions
indiquées dans la partie entretien avant de toucher les pièces.
D Ne jamais toucher les pièces électriques sous tension.
D Porter des gants et des vêtements de protection secs ne comportant
pas de trous.
D S’isoler de la pièce et de la terre au moyen de tapis ou d’autres
moyens isolants suffisamment grands pour empêcher le contact physique éventuel avec la pièce ou la terre.
D
D
D
Ne pas se servir de source électrique àcourant électrique dans les zones
humides, dans les endroits confinés ou là où on risque de tomber.
Se servir d’une source électrique àcourant électrique UNIQUEMENT si le
procédé de soudage le demande.
Si l’utilisation d’une source électrique àcourant électrique s’avère nécessaire, se servir de la fonction de télécommande si l’appareil en est équipé.
D Couper l’alimentation ou arrêter le moteur avant de procéder à l’installation, à la réparation ou à l’entretien de l’appareil. Déverrouiller
l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de
sécurité).
D Installer et mettre à la terre correctement cet appareil conformément à
son manuel d’utilisation et aux codes nationaux, provinciaux et
municipaux.
D Toujours vérifier la terre du cordon d’alimentation − Vérifier et s’assurer que le fil de terre du cordon d’alimentation est bien raccordé à la
borne de terre du sectionneur ou que la fiche du cordon est raccordée
à une prise correctement mise à la terre.
D En effectuant les raccordements d’entrée fixer d’abord le conducteur
de mise à la terre approprié et contre-vérifier les connexions.
D Vérifier fréquemment le cordon d’alimentation pour voir s’il n’est pas
endommagé ou dénudé − remplacer le cordon immédiatement s’il est
endommagé − un câble dénudé peut provoquer une électrocution.
D Mettre l’appareil hors tension quand on ne l’utilise pas.
D Ne pas utiliser des câbles usés, endommagés, de grosseur insuffisante ou mal épissés.
D Ne pas enrouler les câbles autour du corps.
D Si la pièce soudée doit être mise à la terre, le faire directement avec un
câble distinct − ne pas utiliser le connecteur de pièce ou le câble de
retour.
D Ne pas toucher l’électrode quand on est en contact avec la pièce, la
terre ou une électrode provenant d’une autre machine.
LES FUMÉES ET LES GAZ peuvent
être dangereux.
Le soudage génère des fumées et des gaz. Leur
inhalation peut être dangereux pour votre santé.
D
D
D
D
D
D
D Eloigner votre tête des fumées. Ne pas respirer
les fumées.
A l’intérieur, ventiler la zone et/ou utiliser un échappement au niveau
de l’arc pour l’évacuation des fumées et des gaz de soudage.
Si la ventilation est insuffisante, utiliser un respirateur à alimentation d’air homologué.
Lire les spécifications de sécurité des matériaux (MSDSs) et les
instructions du fabricant concernant les métaux, les consommables, les revêtements, les nettoyants et les dégraisseurs.
Travailler dans un espace fermé seulement s’il est bien ventilé ou en
portant un respirateur à alimentation d’air. Demander toujours à un
surveillant dûment formé de se tenir à proximité. Des fumées et des
gaz de soudage peuvent déplacer l’air et abaisser le niveau d’oxygène provoquant des blessures ou des accidents mortels. S’assurer que l’air de respiration ne présente aucun danger.
Ne pas souder dans des endroits situés à proximité d’opérations de
dégraissage, de nettoyage ou de pulvérisation. La chaleur et les
rayons de l’arc peuvent réagir en présence de vapeurs et former des
gaz hautement toxiques et irritants.
Ne pas souder des métaux munis d’un revêtement, tels que l’acier
galvanisé, plaqué en plomb ou au cadmium à moins que le revêtement n’ait été enlevé dans la zone de soudure, que l’endroit soit bien
ventilé, et si nécessaire, en portant un respirateur à alimentation
d’air. Les revêtements et tous les métaux renfermant ces éléments
peuvent dégager des fumées toxiques en cas de soudage.
OM-1311 Page 5
LES RAYONS DE L’ARC peuvent provoquer des brûlures dans les yeux et
sur la peau.
Le rayonnement de l’arc du procédé de soudage
génère des rayons visibles et invisibles intenses
(ultraviolets et infrarouges) susceptibles de provoquer
des brûlures dans les yeux et sur la peau. Des étincelles sont projetées
pendant le soudage.
D Porter un casque de soudage muni d’un écran de filtre approprié pour
protéger votre visage et vos yeux pendant le soudage ou pour regarder (voir ANSI Z49.1 et Z87.1 énuméré dans les normes de sécurité).
D Porter des protections approuvés pour les oreilles si le niveau sondre est
trop élevé.
D Utiliser des écrans ou des barrières pour protéger des tiers de l’éclair
et de l’éblouissement; demander aux autres personnes de ne pas regarder l’arc.
D Porter des vêtements de protection constitué dans une matière durable, résistant au feu (cuir ou laine) et une protection des pieds.
LE SOUDAGE peut provoquer un
incendie ou une explosion.
Le soudage effectué sur des conteneurs fermés tels
que des réservoirs, tambours ou des conduites peut
provoquer leur éclatement. Des étincelles peuvent être
projetées de l’arc de soudure. La projection d’étincelles, des pièces chaudes et des équipements chauds peut provoquer des
incendies et des brûlures. Le contact accidentel de l’électrode avec des
objets métalliques peut provoquer des étincelles, une explosion, un
surchauffement ou un incendie. Avant de commencer le soudage, vérifier
et s’assurer que l’endroit ne présente pas de danger.
D Se protéger et d’autres personnes de la projection d’étincelles et de
métal chaud.
D Ne pas souder dans un endroit là où des étincelles peuvent tomber sur
des substances inflammables.
D Déplacer toutes les substances inflammables à une distance de 10,7
m de l’arc de soudage. En cas d’impossibilité les recouvrir soigneusement avec des protections homologués.
D Des étincelles et des matériaux chauds du soudage peuvent facilement passer dans d’autres zones en traversant de petites fissures et
des ouvertures.
D Surveiller tout déclenchement d’incendie et tenir un extincteur à proximité.
D Le soudage effectué sur un plafond, plancher, paroi ou séparation
peut déclencher un incendie de l’autre côté.
D Ne pas effectuer le soudage sur des conteneurs fermés tels que des
réservoirs, tambours, ou conduites, à moins qu’ils n’aient été préparés correctement conformément à AWS F4.1 (voir les normes de
sécurité).
D Brancher le câble sur la pièce le plus près possible de la zone de soudage pour éviter le transport du courant sur une longue distance par
des chemins inconnus éventuels en provoquant des risques d’électrocution et d’incendie.
D Ne pas utiliser le poste de soudage pour dégeler des conduites gelées.
D En cas de non utilisation, enlever la baguette d’électrode du porteélectrode ou couper le fil à la pointe de contact.
D Porter des vêtements de protection dépourvus d’huile tels que des
gants en cuir, une chemise en matériau lourd, des pantalons sans revers, des chaussures hautes et un couvre chef.
D Avant de souder, retirer toute substance combustible de vos poches
telles qu’un allumeur au butane ou des allumettes.
DES PARTICULES VOLANTES
peuvent blesser les yeux.
D Le soudage, l’écaillement, le passage de la pièce
à la brosse en fil de fer, et le meulage génèrent
des étincelles et des particules métalliques volantes. Pendant la période de refroidissement des soudures, elles risquent de projeter du laitier.
D
Porter des lunettes de sécurité avec écrans latéraux ou un écran facial.
OM-1311 Page 6
LES ACCUMULATIONS DE GAZ risquent de provoquer des blessures ou
même la mort.
D
D
Fermer l’alimentation du gaz protecteur en cas de
non utilisation.
Veiller toujours à bien aérer les espaces confinés ou se servir d’un respirateur d’adduction d’air homologué.
DES PIÈCES CHAUDES peuvent provoquer des brûlures graves.
D Ne pas toucher des parties chaudes à mains nues
D Prévoir une période de refroidissement avant
d’utiliser le pistolet ou la torche.
LES CHAMPS MAGNÉTIQUES peuvent
affecter les stimulateurs cardiaques.
D
D
Porteurs de stimulateur cardiaque, restez à distance.
Les porteurs d’un stimulateur cardiaque doivent
d’abord consulter leur médecin avant de s’approcher
des opérations de soudage à l’arc, de gougeage ou
de soudage par points.
LE BRUIT peut affecter l’ouïe.
Le bruit des processus et des équipements peut affecter
l’ouïe.
D
Porter des protections approuvés pour les oreilles si
le niveau sondre est trop élevé.
Si des BOUTEILLES sont endommagées, elles pourront exploser.
Des bouteilles de gaz protecteur contiennent du gaz
sous haute pression. Si une bouteille est endommagée, elle peut exploser. Du fait que les bouteilles de gaz
font normalement partie du procédé de soudage, les
manipuler avec précaution.
D Protéger les bouteilles de gaz comprimé d’une chaleur excessive,
des chocs mécaniques, du laitier, des flammes ouvertes, des étincelles et des arcs.
D Placer les bouteilles debout en les fixant dans un support stationnaire ou dans un porte-bouteilles pour les empêcher de tomber ou de
se renverser.
D Tenir les bouteilles éloignées des circuits de soudage ou autres circuits électriques.
D Ne jamais placer une torche de soudage sur une bouteille à gaz.
D Une électrode de soudage ne doit jamais entrer en contact avec une
bouteille.
D Ne jamais souder une bouteille pressurisée − risque d’explosion.
D Utiliser seulement des bouteilles de gaz protecteur, régulateurs,
tuyaux et raccords convenables pour cette application spécifique;
les maintenir ainsi que les éléments associés en bon état.
D Ne pas tenir la tête en face de la sortie en ouvrant la soupape de la
bouteille.
D Maintenir le chapeau de protection sur la soupape, sauf en cas d’utilisation ou de branchement de la bouteille.
D Lire et suivre les instructions concernant les bouteilles de gaz comprimé, les équipements associés et les publications P-1 CGA énumérées dans les normes de sécurité.
1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement
et la maintenance
Risque D’INCENDIE OU
D’EXPLOSION.
DES ORGANES MOBILES peuvent
provoquer des blessures.
D Ne pas placer l’appareil sur, au-dessus ou à proximité de surfaces infllammables.
D Rester à l’écart des organes mobiles comme le
ventilateur.
D Maintenir fermés et fixement en place les portes,
panneaux, recouvrements et dispositifs de
protection.
D Ne pas installer l’appareil à proximité de produits inflammables
D Ne pas surcharger l’installation électrique − s”assurer que l’alimentation est correctement dimensionné et protégé avant de mettre
l’appareil en service.
LE RAYONNEMENT HAUTE FRÉQUENCE (H.F.) risque de provoquer
des interférences.
LA CHUTE DE L’APPAREIL peut
blesser.
D Utiliser l’anneau de levage uniquement pour soulever l’appareil, NON PAS les chariot, les bouteilles de gaz ou tout autre accessoire.
D Utiliser un engin d’une capacité appropriée pour
soulever l’appareil.
D En utilisant des fourches de levage pour déplacer l’unité, s’assurer
que les fourches sont suffisamment longues pour dépasser du côté
opposé de l’appareil.
L’EMPLOI EXCESSIF peut
SURCHAUFFER L’ÉQUIPEMENT.
D
D
D
D
D
D Prévoir une période de refroidissement, respecter le cycle opératoire nominal.
D Réduire le courant ou le cycle opératoire avant de
recommancer le soudage.
LE SOUDAGE À L’ARC risque de
provoquer des interférences.
D Ne pas obstruer les passages d’air du poste.
LES CHARGES ÉLECTROSTATIQUES peuvent endommager les circuits imprimés.
D Établir la connexion avec la barrette de terre
avant de manipuler des cartes ou des pièces.
D Utiliser des pochettes et des boîtes antistatiques
pour stocker, déplacer ou expédier des cartes de
circuits imprimes.
DES ORGANES MOBILES peuvent
provoquer des blessures.
D Ne pas s’approcher des organes mobiles.
D Ne pas s’approcher des points de coincement
tels que des rouleaux de commande.
LES FILS DE SOUDAGE peuvent provoquer des blessures.
D Ne pas appuyer sur la gachette avant d’en avoir
reçu l’instruction.
D Ne pas diriger le pistolet vers soi, d’autres personnes ou toute pièce mécanique en engageant le fil
de soudage.
D Le rayonnement haute frequence peut provoquer
des interférences avec les équipements de radio−navigation et de communication, les services
de sécurité et les ordinateurs.
Demander seulement à des personnes qualifiées familiarisées
avec des équipements électroniques de faire fonctionner l’installation.
L’utilisateur est tenu de faire corriger rapidement par un électricien
qualifié les interférences résultant de l’installation.
Si le FCC signale des interférences, arrêter immédiatement l’appareil.
Effectuer régulièrement le contrôle et l’entretien de l’installation.
Maintenir soigneusement fermés les portes et les panneaux des
sources de haute fréquence, maintenir les éclateurs à une distance
correcte et utiliser une terre et et un blindage pour réduire les interférences éventuelles.
D
D
D
D
D
D L’énergie électromagnétique risque de provoquer
des interférences pour l’équipement électronique
sensible tel que les ordinateurs et l’équipement
commandé par ordinateur tel que les robots.
Veiller à ce que tout l’équipement de la zone de soudage soit compatible électromagnétiquement.
Pour réduire la possibilité d’interférence, maintenir les câbles de
soudage aussi courts que possible, les grouper, et les poser aussi
bas que possible (ex. par terre).
Veiller à souder à une distance de 100 mètres de tout équipement
électronique sensible.
Veiller à ce que ce poste de soudage soit posé et mis à la terre
conformément à ce mode d’emploi.
En cas d’interférences après avoir pris les mesures précédentes, il
incombe à l’utilisateur de prendre des mesures supplémentaires telles que le déplacement du poste, l’utilisation de câbles blindés, l’utilisation de filtres de ligne ou la pose de protecteurs dans la zone de
travail.
LES CHAMPS MAGNÉTIQUES peuvent
affecter les stimulateurs cardiaques.
D Porteurs de stimulateur cardiaque, restez à distance.
D Les porteurs d’un stimulateur cardiaque doivent
d’abord consulter leur médecin avant de s’approcher des opérations de soudage à l’arc, de gougeage ou de soudage par points.
OM-1311 Page 7
1-4. Principales normes de sécurité
Safety in Welding and Cutting, norme ANSI Z49.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL 33126
Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent
of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Recommended Safe Practice for the Preparation for Welding and Cutting of Containers That Have Held Hazardous Substances, norme AWS
F4.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL
33126
National Electrical Code, NFPA Standard 70, de la National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
de la Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
Règles de sécurité en soudage, coupage et procédés connexes, norme
CSA W117.2, de l’Association canadienne de normalisation, vente de
normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.
Safe Practices For Occupation And Educational Eye And Face Protection, norme ANSI Z87.1, de l’American National Standards Institute,
1430 Broadway, New York, NY 10018.
Cutting and Welding Processes, norme NFPA 51B, de la National Fire
Protection Association, Batterymarch Park, Quincy, MA 02269.
1-5. Information sur les champs électromagnétiques
Données sur le soudage électrique et sur les effets, pour l’organisme,
des champs magnétiques basse fréquence
Afin de réduire les champs électromagnétiques dans l’environnement
de travail, respecter les consignes suivantes :
1
Le courant de soudage, pendant son passage dans les câbles de soudage, causera des champs électromagnétiques. Il y a eu et il y a encore
un certain souci à propos de tels champs. Cependant, après avoir examiné plus de 500 études qui ont été faites pendant une période de
recherche de 17 ans, un comité spécial ruban bleu du National Research Council a conclu: “L’accumulation de preuves, suivant le
jugement du comité, n’a pas démontré que l’exposition aux champs
magnétiques et champs électriques à haute fréquence représente un
risque à la santé humaine”. Toutefois, des études sont toujours en cours
et les preuves continuent à être examinées. En attendant que les conclusions finales de la recherche soient établies, il vous serait
souhaitable de réduire votre exposition aux champs électromagnétiques pendant le soudage ou le coupage.
OM-1311 Page 8
2
3
4
5
Garder les câbles ensembles en les torsadant ou en les
attachant avec du ruban adhésif.
Mettre tous les câbles du côté opposé de l’opérateur.
Ne pas courber pas et ne pas entourer pas les câbles autour de
votre corps.
Garder le poste de soudage et les câbles le plus loin possible de
vous.
Relier la pince de masse le plus près possible de la zone de
soudure.
Consignes relatives aux stimulateurs cardiaques :
Les personnes qui portent un stimulateur cardiaque doivent avant tout
consulter leur docteur. Si vous êtes déclaré apte par votre docteur, il est
alors recommandé de respecter les consignes ci−dessus.
SECTION 2 − INSTALLATION
2-1. Specifications
Rated Welding
Output
Amperage Range
DC
Maximum OpenCircuit Voltage DC
40 − 250
42
200 A @ 28 Volts DC,
60% Duty Cycle
250 A @ 28 Volts DC,
40% Duty Cycle
Amperes Input at Rated Load
Output, 50 or 60 Hz, Single-Phase
200 V
230 V
460 V
575 V
KVA
KW
46
1.1*
40
1.3*
20
0.5*
16
0.4*
9.5
0.31*
8.3
0.18*
Wire Type And Diameter
Solid Steel /
Stainless Steel
Flux Cored/
Aluminum
.023 − .045 in
(0.6 − 1.2 mm)
.030 − .035 in
(0.8 − 0.9 mm) And
3/64 in (1.2 mm) Alu
Wire Feed Speed Range
Overall Dimensions
Weight
Length: 37 in (940 mm)
90 − 1030 IPM (2.9 − 26.2 m/min)
Width: 19 in (483 mm)
225 lb
(102 kg)
Height: 32 in (889 mm)
*While idling
Operating Temperature Range − −20C to +40C
Storage Temperature Range − -30C to + 50C
2-2. Volt-Ampere Curve
The volt-ampere curves show the
minimum and maximum voltage
and amperage output capabilities of
the welding power source. Curves
of other settings fall between the
curves shown.
ssb1.1 10/91 − SB-049 424-C
OM-1311 Page 9
2-3. Duty Cycle And Overheating
Duty Cycle is percentage of 10 minutes that unit can weld at rated load
without overheating.
If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
voltage, or duty cycle before
welding.
Y Exceeding duty cycle can
damage unit and void warranty.
60% Duty Cycle At 200 Amperes
6 Minutes Welding
4 Minutes Resting
Overheating
A or V
0
15
OR
Reduce Duty Cycle
Minutes
duty1 4/95 − SB-150 215
OM-1311 Page 10
2-4. Installing Work Clamp
1
2
Slide boot onto work cable. Route
cable out front panel opening from
inside.
4
3
Negative (−) Output Terminal
Connect cable to terminal and
cover connection with boot.
5
2
Work Cable
Boot
4
5
Hardware
Work Clamp
Route cable through clamp handle
and secure as shown.
1
Close door.
Tools Needed:
3
1/2, 3/4 in
ST-800 918-B
2-5. Installing Gas Supply
1
2
Cylinder Rack
Chain
Obtain gas cylinder and chain cylinder to rack.
3
4
5
Gas Hose Fitting
CO2 Washer
Regulator
Install washer and regulator onto
cylinder.
6
Gas Hose Connection
Obtain gas hose with fittings and
install between regulator and welding power source.
7
7
Flow Adjust
Typical flow rate is 20 cfh (cubic feet
per hour).
6
5
4
1
2
3
Tools Needed:
5/8, 1-1/8 in
ST-154 623-A / Ref. ST-109 492
OM-1311 Page 11
2-6. Installing Welding Gun
1
2
3
1
2
Drive Assembly
Gun Securing Knob
Gun End
Loosen securing knob. Insert gun
end through opening until it bottoms
against drive assembly. Tighten
nut.
4
4
Gun Trigger Plug
Insert plug into receptacle, and
tighten threaded collar.
Close door.
3
Ref. ST-800 921-B
2-7. Installing Wire Spool And Adjusting Hub Tension
Use compression spring with
8 in (200 mm) spools.
When a slight force is needed to turn spool, tension is set.
Tools Needed:
15/16 in
OM-1311 Page 12
ST-072573-B
2-8. Setting Gun Polarity
1
Shown As Shipped − Set For Electrode
Positive (DCEP) For Solid Steel Or
Aluminum Wires (GMAW Process).
1
Polarity Changeover Label
(Located Near Drive
Assembly)
Always read and follow manufacture’s recommended polarity.
Wire Drive Assembly Lead
To Positive (+) Output Terminal
Work Clamp Lead To
Negative (−) Output Terminal
GUN POLARITY
CHANGEOVER CONNECTIONS
Tools Needed:
3/4, 11/16 in
Reverse Lead Connections − For Electrode
Negative (DCEN) For Flux Cored Wires
(FCAW Process). Drive Assembly
Becomes Negative
S-144 449-D
2-9. Positioning Jumper Links
230 VOLTS
Check input voltage available at
site.
1
Jumper Links Access Door
Open door.
460 VOLTS
200 VOLTS
2
2
3
Jumper Link Label
Jumper Links Location
Move jumper links to match input
voltage, and label on unit.
Close and secure access door.
575 VOLTS
230 VOLTS
S-156 140
S-153 980
1
Tools Needed:
3/8 in
3
Ref. ST-800 922-B
OM-1311 Page 13
2-10. Electrical Service Guide
Input Voltage
200
230
460
575
Input Amperes At Rated Output
46
40
20
16
Max Recommended Standard Fuse Or Circuit
Breaker Rating In Amperes
70
60
30
25
Min Input Conductor Size In AWG/Kcmil
8
8
12
14
Max Recommended Input Conductor Length
In Feet (Meters)
89 (27)
117 (36)
188 (57)
190 (58)
Min Grounding Conductor Size In AWG/Kcmil
8
8
12
14
Reference: 1996 National Electrical Code (NEC).
S-0092J
2-11. Selecting A Location And Connecting Input Power
1
Rating Label
Supply correct input power.
2
3
Plug
Receptacle
Connect plug to receptacle.
4
18 in (457 mm) of
space for airflow
Line Disconnect Device
See Section 2-10.
Y Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
Y Do not move or operate unit
where it could tip.
Y Always connect
grounding conductor first.
= GND/PE
4
L1
L2
2
1
3
L2
L1
230 VAC, 1
ST-800 923-A
OM-1311 Page 14
2-12. Threading Welding Wire
4
1
Wire Spool
2
Welding Wire
3
Inlet Wire Guide
4
Pressure Adjustment Knob
5
Drive Roll
6
Outlet Wire Guide
7
Gun Conduit Cable
Lay gun cable out straight.
7
Tools Needed:
1
2
3
5
6
4 in
(102 mm)
6 in
(150 mm)
Open pressure assembly.
Pull and hold wire; cut off end.
Push wire thru guides into gun;
continue to hold wire.
Tighten
Close and tighten pressure
assembly, and let go of wire.
Remove gun nozzle and contact tip.
Turn On.
WOOD
Press gun trigger until wire
comes out of gun. Reinstall
contact tip and nozzle.
Feed wire to check drive roll pressure.
Tighten knob enough to prevent slipping.
Cut off wire. Close
and latch door.
Ref. ST-148 261-C / ST-159 218-B / ST-801 083 / S-0627-A
OM-1311 Page 15
SECTION 3 − OPERATION
3-1. Front Panel Controls
Controls For Standard Units
1
Wire Speed Control
The scale around the control is percent, not wire feed speed.
1
2
2
Voltage Switch
Use control and Voltage Range Selector (see Section 3-2) to set arc
voltage. Step 6 of Low range and
Step 1 of High range overlap.
3
4
Pilot Light
Power Switch
3
4
Ref. ST-171 639-C / Ref. ST-174 843-A
3-2. Center Baffle Controls
1
1
PRESS TO RESET
CB1
2
2
DO NOT SWITCH
UNDER LOAD
WIRE
MODE
FULL
LOW
Wire Mode Switch
For better control of wire speed use
the Low position when wire speed is
between 90 and 670 ipm. Use the
Full position when wire speed is between 150 ipm and 1030 ipm.
Voltage Range Selector
Place switch in desired position.
VOLTAGE
RANGE
HIGH
LOW
Ref. ST-800 919 / S-171 601
OM-1311 Page 16
SECTION 4 − MAINTENANCE & TROUBLESHOOTING
4-1. Routine Maintenance
. Maintain more often
Y Disconnect power
before maintaining.
during severe conditions.
3 Months
Clean And
Tighten
Weld
Terminals
Repair Or
Replace
Cracked
Cables And
Cords
Replace
Damaged Or
Unreadable
Labels
6 Months
Remove drive roll and
carrier. Apply light coat
of oil or grease to drive
motor shaft.
Blow Out Or
Vacuum Inside
4-2. Circuit Breaker CB1
1
Circuit Breaker CB1
If CB1 opens, wire feeding stops.
2
Welding Gun
Check gun liner for blockage or
kinks.
3
Wire Drive Assembly
Check for jammed wire, binding
drive gear or misaligned drive rolls.
1
Allow cooling period and reset
breaker. Close door.
2
3
Ref. ST-800 924-A
OM-1311 Page 17
4-3. Fuses F1 And F2
Y Turn Off unit, and disconnect
input power.
1
Fuse F1 (See Parts List For
Rating)
F1 protects the 115 volts ac winding
of transformer T1. If F1 opens, all
weld output stops and pilot light PL1
goes out.
2
2
Fuse F2 (See Parts List For
Rating)
F2 protects the 24 volts ac winding
of transformer T1. If F2 opens, all
weld output stops.
1
Tools Needed:
3/8 in
Ref. ST-800 928-B
4-4. Changing Drive Roll And Wire Inlet Guide
1
2
5
3
2
Securing Screw
Inlet Wire Guide
Loosen screw. Slide tip as close to
drive rolls as possible without touching. Tighten screw.
3
Anti-Wear Guide
Install guide as shown.
1
4
Drive Roll
Install correct drive roll for wire size
and type.
5
Turn nut one click to secure drive
roll.
Tools Needed:
5/64 in
Drive Roll Securing Nut
4
7/16 in
ST-150 227-C
4-5. Replacing Gun Contact Tip
Y Turn
Off
unit
before
replacing contact tip.
1
2
Nozzle
Contact Tip
Cut off welding wire at contact tip.
Remove nozzle.
2
1
Remove contact tip and install new
contact tip. Reinstall nozzle.
Tools Needed:
ST-149 326-B
4-6. Unicable Repair
To repair or replace unicable, order Unicable Clamp Kit, part number 172 018.
OM-1311 Page 18
4-7. Cleaning Or Replacing Gun Liner
Tools Needed:
Y Disconnect gun first.
3/8 in
Head tube
Remove nozzle, contact tip,
adapter, and wire outlet guide.
3/8 in
Wire Outlet Guide
Remove liner.
Lay gun cable out straight
before installing new liner.
To Reassemble Gun:
Insert new liner.
Install and tighten wire outlet guide.
Blow out gun casing.
Cut liner off 3/4 in (20 mm) (3/8 in
[9.5 mm] for aluminum) from head
tube.
Install adapter, contact tip, and
nozzle.
Ref. ST-800 797-A
OM-1311 Page 19
4-8. Replacing Switch And/Or Head Tube
Y Disconnect gun first.
3
1
4
2
Remove handle
locking nut.
Secure head
tube in vice.
5
Remove shock washers from front and
rear of head tube.
6
Slide handle.
Remove switch housing. Note: If installing new
switch, push switch lead connectors onto terminal of
new switch (polarity is not important). Install switch
back into handle, and secure with handle locking nut.
If replacing head tube, continue to end of figure.
Loosen jam nut. Remove
from vice and turn head
tube out by hand.
Do not disturb cable connection between
cable connector and connector nut.
7
Install both existing shock washers
to new head tube and hand-tighten
head tube into connector cable.
9
8
Place head tube in vice and tighten
to within 1/8 in (3.2 mm) spacing between connector cable and body.
Remove from vice. Reposition
handle and install switch housing.
Secure with handle locking nut.
Tools Needed:
3/4 in
Ref. ST-800 795-A
OM-1311 Page 20
4-9. Troubleshooting
Welding Trouble
No weld output; wire does not feed.
Remedy
Secure power cord plug in receptacle (see Section 2-11).
Reset circuit breaker CB1 (see Section 4-2).
Replace fuse F1 and/or F2 (see Section 4-3).
Replace building line fuse or reset circuit breaker if open (see Section 2-11).
Secure gun trigger plug in receptacle or repair leads, or replace trigger switch (see Section 2-6 and/or
4-8).
Thermostat TP1 open (overheating). Allow fan to run; the thermostat will close when the unit has cooled
(see Section 2-3).
No weld output; wire feeds.
Connect work clamp to get good metal to metal contact.
Replace contact tip (see Section 4-5).
Low weld output.
Connect unit to proper input voltage or check for low line voltage (see Section 2-11).
Wire Drive/Gun Trouble
Remedy
Electrode wire feeding stops during Straighten gun cable and/or replace damaged parts (see Section 4-7).
welding.
Adjust drive roll pressure (see Section 2-12).
Readjust hub tension (see Section 2-7).
Replace contact tip if blocked (see Section 4-5).
Clean or replace wire inlet guide or liner if dirty or plugged (see Section 4-7).
Replace drive rolls if worn or slipping (see Section 4-4).
Secure gun trigger plug in receptacle or repair leads, or replace trigger switch (see Section 2-6 and/or
4-8).
Check and replace F1 and/or F2 (see Section 4-3).
Check and clear any restrictions at drive assembly and liner (see Section 4-7).
Have nearest Factory Authorized Service Agent check drive motor.
Check relay CR1, and replace if necessary.
OM-1311 Page 21
SECTION 5 − ELECTRICAL DIAGRAM
SB-173 544-E
Figure 5-1. Circuit Diagram For Welding Power Source
OM-1311 Page 22
Notes
OM-1311 Page 23
SECTION 6 − PARTS LIST
. Hardware is common and
not available unless listed.
11
10
8
9
Figure 6-2 − 2
Figure 6-4 − 7
1
3
6
5
12
13
14
15
16
Figure 6-6 - 20
17
18
Figure 6-5 − 19
ST-800 930-D
Figure 6-1. Main Assembly
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 6-1. Main Assembly
. . . 1 . . . . . . . . . . . . . . . . . . . 146 168
. . . . . . . . . . . PLG7 . . . . . . . 083 526
. . . . . . . . . . . . . . . . . . . . . . . . . 009 418
. . . 2 . . . . . . . . . . . . . . . . . Figure 6-2
. . . 3 . . . . . . . T1 . . . . . . . . . 171 658
. . . 3 . . . . . . . T1 . . . . . . . . . 172 520
. . . 5 . . . . . . . . . . . . . . . . . . . 186 758
. . . 6 . . . . . . . Z1 . . . . . . . . . 171 213
. . . 7 . . . . . . . . . . . . . . . . . Figure 6-4
OM-1311 Page 24
. . PANEL, center enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . HOUSING RECEPTACLE & SOCKETS, (consisting of) . . . . . . . . . 1
. . . . TERMINAL, female 1skt 20-14 wire . . . . . . . . . . . . . . . . . . . . . . . 12
. . BAFFLE, center w/components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . TRANSFORMER, pwr main (200/230) . . . . . . . . . . . . . . . . . . . . . . . . 1
. . TRANSFORMER, pwr main (230/460/575) . . . . . . . . . . . . . . . . . . . . 1
. . WHEEL, polyprolene 10 in dia x 2.250 wide x .750 bore . . . . . . . . . 2
. . STABILIZER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . PANEL, rear w/components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 6-1. Main Assembly
. . . 8 . . . . . . . . . . . . . . . . . . . 146 165 . . PANEL, side LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 9 . . . . . . . . . . . . . . . . . . . 089 899 . . LATCH, slide flush mtg hole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 10 . . . . . . . . . . . . . . . . . . . 146 167 . . PANEL, side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 11 . . . . . . . . . . . . . . . . . . . 134 464 . . LABEL, warning general precautionary . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 12 . . . . . . . . . . . . . . . . . . +170 513 . . WRAPPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . . . . . 117 860 . . BLANK, snap-in nyl .187mtg hole . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 13 . . . . . . . . . . . . . . . . . . . 047 721 . . CORD SET, pwr 250V 8-10ga 3/c 8ft . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 13 . . . . . . . . . . . . . . . . . . . 187 255 . . CORD SET, pwr 250V 8-10ga 3/c 12ft (230/460/575) . . . . . . . . . . . 1
. . . 14 . . . . . . . . . . . . . . . . . . . 146 161 . . BASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 15 . . . . . . . . . . . . . . . . . . . 052 692 . . AXLE, running gear (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 16 . . . . . . . . . . . . . . . . . . . 121 614 . . . . RING, retaining ext .750 shaft x .085grv depth . . . . . . . . . . . . . . . 2
. . . 17 . . . . . . R1 . . . . . . . . 091 685 . . RESISTOR, WW fxd 50W 25 ohm . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 18 . . . . . . . . . . . . . . . . . . . 008 999 . . CASTER, plstc swvl 4 in dia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 19 . . . . . . . . . . . . . . . . . Figure 6-5 . . PANEL, front w/components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 20 . . . . . . . . . . . . . . . . . . . 169 596 . . GUN, 12 ft .030-.035 wire (Fig 6-4) . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . . . . . 192 121 . . REGULATOR/FLOWMETER, 10-50 CFH . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . . . . . 144 108 . . HOSE, gas 5ft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . . . . . 130 750 . . CLAMP, ground 350A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . . . . . 600 318 . . CABLE, weld cop strd No. 3 (order by ft) . . . . . . . . . . . . . . . . . . . . 10ft
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-1311 Page 25
1
2
4
3
5
11
6
10
7
31
12
13
8
9
14
30
29
15
16
20
21
18
17
Fig.6−3 − 28
22
19
27
23
26
25
24
. Hardware is common and
not available unless listed.
ST-800 931-C
Figure 6-2. Baffle, Center w/Components
OM-1311 Page 26
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 6-2. Baffle, Center w/Components (Fig 6-1 Item 2)
. . 1 . . . . . . . . . . . . 058 427
. . 2 . . . . . . . . . . . . 085 980
. . 3 . . . . . . . . . . . . 605 941
. . 4 . . . . . . . . . . . . 186 437
. . 5 . . . . . . . . . . . . 057 971
. . 6 . . . . . . . . . . . . 057 745
. . 7 . . . . . . . . . . . . 186 435
. . 8 . . . . . . . . . . . . 186 436
. . 9 . . . . . . . . . . . . 177 307
. . 10 . . . . . . . . . . . 174 812
. . . . . . . . . . . . . . . . . 186 998
. . 11 . . . . . . . . . . . 083 147
. . 12 . . . . . . . . . . . 082 902
. . 13 . . . . . . . . . . . 185 643
. . 14 . . . . C5 . . . 184 584
. . . . . . . . . . . . . . . . . 185 642
. . 15 . . . . W . . . . 186 355
. . . . . . . . . . . . . . . . . 114 786
. . 16 . . . . . . . . . . . 134 201
. . 17 . . . PC1 . . . 173 002
. . . . . . . . . CR1 . . . *080 388
. . 18 . . . . F2 . . . *012 658
. . 19 . . . . F1 . . . *073 426
. . . . . . . . PLG3 . . 165 896
. . . . . . . . PLG4 . . 135 558
. . . . . . . . PLG5 . . 165 745
. . 20 . . . CB1 . . . 083 431
. . 21 . . . . S3 . . . 011 609
. . 22 . . . . S4 . . . 171 610
. . . . . . . . . . . . . . . . . 186 058
. . 23 . . . TE1 . . . 189 452
. . 23 . . . TE1 . . . 153 427
. . . . . . . . . . . . . . . . . 038 618
. . 24 . . . . . . . . . . . 010 199
. . 25 . . . POS . . 039 047
. . 26 . . . NEG . . 039 046
. . . . . . . . . C6,7 . . 128 750
. . 27 . . . . . . . . . . . 071 971
. . 28 . . . . . . . . . . . . Fig 6-3
. . 29 . . . . . . . . . . . 148 956
. . 30 . . . . . . . . . . +144 933
. . 31 . . . . . . . . . . . 021 469
. . RING, retaining spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . NUT, stl hex full .625-11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . WASHER, flat stl .640 ID x 1.000 OD x 14ga thk . . . . . . . . . . . . . . . . . . . . . . . 1
. . SPRING, cprsn .845 OD x .110 wire x 1.500 . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . WASHER, flat stl keyed 1.500dia x .125thk . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . SPRING, cprsn 2.430 OD x .090 wire x 2.500 . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . HUB, spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . WASHER, brake plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . REEL, support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . BAFFLE, center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . KIT, capacitor bank (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . GROMMET, scr No. 8/10 panel hole .312sq .500 high . . . . . . . . . . . . . . . . 6
. . . . STRIP, mtg center capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . STRIP, mtg capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . CAPACITOR, elctlt 15000uf 45VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
. . . . INSULATOR, capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . CONTACTOR, def prp 60A 3P 120VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . LINK, connecting contactor terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . STAND-OFF SUPPORT, PC card .312/.375 w/post & lock . . . . . . . . . . . . . . 4
. . CIRCUIT CARD, motor speed control (consisting of) . . . . . . . . . . . . . . . . . . . 1
. . . . RELAY, encl 24 VAC 3PDT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . FUSE, mintr gl slo-blo 2A 125V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . FUSE, mintr gl slo-blo 5A 125V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . CIRCUIT BREAKER, man reset 1P 5A 250VAC . . . . . . . . . . . . . . . . . . . . . . . 1
. . SWITCH, tgl SPDT 15A 125VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . SWITCH, selector 2 position (When ordering this part order 186 058 also) 1
. . COVER, dust range switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . TERMINAL ASSEMBLY, pri 1ph 2V (200/230) (consisting of) . . . . . . . . . . . . 1
. . TERMINAL ASSEMBLY, pri 1ph 3V (230/460/575) (consisting of) . . . . . . . . 1
. . . . LINK, jumper term bd pri . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . As Rq’d
. . TUBING, stl .275 ID x .048 wall x 1.000 lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . TERMINAL, pwr output red (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . TERMINAL, pwr output black (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . CAPACITOR, cer disc .1uf 500VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . COVER, cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . WIRE DRIVE & GEARS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . HANDLE, switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . DOOR, access chgov . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . LABEL, danger high voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
*Recommended Spare Parts.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-1311 Page 27
See Table 6-1
Drive Roll & Wire Guide Kits.
. Hardware is common and
13
9
not available unless listed.
8
14
10
11
12
7
6
5
4
3
16
2
26
25
1
23
24
22
15
16
21
20
19
18
ST-148 529-H
Figure 6-3. Wire Drive And Gears
Table 6-1. Drive Roll And Wire Guide Kits
IMPORTANT: Base selection of drive rolls upon the following recommended usages:
1. V-Grooved rolls for hard wire.
2. U- Grooved rolls for soft and soft shelled cored wires.
3. U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types).
4. V-Knurled rolls for hard shelled cored wires.
5. Drive roll types may be mixed to suit particular requirements (example: V-Knurled roll in combination with
U-Grooved).
Wire Diameter
Drive Roll
Part No.
Type
Inlet
Wire Guide
087 131
087 130
V-Grooved
056 192
0.8 mm
079 594
053 695
V-Grooved
056 192
.035 in.
0.9 mm
079 595
053 700
V-Grooved
056 192
.045 in.
1.2 mm
079 596
053 697
V-Grooved
056 193
Fraction
Decimal
Metric
.023/.025 in.
.023/.025 in.
0.6 mm
.030 in.
.030 in.
.035 in.
.045 in.
Kit No.
Ref. S-0026-B/7-91
OM-1311 Page 28
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 6-3. Wire Drive And Gears (Fig 6-2 Item 28)
. . . 1 . . . . . . . . . . . . . . . . . . . 602 009
. . . 2 . . . . . . . . . . . . . . . . . . . 172 075
. . . 3 . . . . . . . . . . . . . . . . . . . 166 072
. . . 4 . . . . . . . . . . . . . . . . . . . 010 224
. . . 5 . . . . . . . . . . . . . . . . . . . 182 788
. . . 6 . . . . . . . . . . . . . . . . . . . 085 242
. . . 7 . . . . . . . . . . . . . . . . . . . 085 244
. . . 8 . . . . . . . . . . . . . . . . . . . 010 231
. . . 9 . . . . . . . . . . . . . . . . . . . 085 243
. . . 10 . . . . . . . . . . . . . . . . . . . 166 071
. . . 11 . . . . . . . . . . . . . . . . . . . 079 634
. . . 12 . . . . . . . . . . . . . . . . . . . 151 828
. . . 13 . . . . . . . . . . . . . . . . . . . 173 616
. . . 14 . . . . . . PM . . . . . . . . 173 435
. . . . . . . . . . . . . . . . . . . . . . . . . 193 633
. . . . . . . . . . . . . . . . . . . . . . . . . 193 634
. . . . . . . . . . . . . . . . . . . . . . . . . 193 635
. . . 15 . . . . . . . . . . . . . . . . . . . 079 633
. . . 16 . . . . . . . . . . . . . . . . . . . 601 966
. . . 18 . . . . . . . . . . . . . . . . . . . 604 538
. . . 19 . . . . . . . . . . . . . . . . . . . 124 778
. . . 20 . . . . . . . . . . . . . . . . . . . 173 619
. . . 21 . . . . . . . . . . . . . . . . . . . 174 609
. . . 22 . . . . . . . . . . . . . . . . . . . 174 610
. . . 23 . . . . . . . . . . . . . . . . . . . 192 029
. . . 24 . . . . . . . . . . . . . . . . . . . 173 620
. . . 25 . . . . . . . . . . . . . . . . . . . 602 243
. . . 26 . . . . . . . . . . . . . . . . . . . 602 213
. . . . . . . . . . . . . . . . . . . . . . . . . 056 192
. . . . . . . . . . . . . . . . . . . . . . . . ♦056 193
. . . . . . . . . . . . . . . . . . . . . . . . . 045 233
. . . . . . . . . . . . . . . . . . . . . . . . ♦087 130
. . . . . . . . . . . . . . . . . . . . . . . . ♦053 695
. . . . . . . . . . . . . . . . . . . . . . . . . 053 700
. . . . . . . . . . . . . . . . . . . . . . . . ♦053 697
. . SCREW, .250-20 x 1.25 soc hd gr 8 . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CARRIER, drive roll w/components . . . . . . . . . . . . . . . . . . . . . . . . . .
. . SPACER, gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . PIN, spring CS .187 x 1.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . HOUSING, adapter gun/feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . FASTENER, pinned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . WASHER, cupped stl .328 ID x .812 OD x .125 lip . . . . . . . . . . . . .
. . SPRING, cprsn .770 OD x .105 wire x 1.225 . . . . . . . . . . . . . . . . . .
. . KNOB, adj tension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . LEVER, mtg pressure gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . PIN, hinge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . PIN, cotter hair .054 x .750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . COVER, right angle motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . MOTOR, gear 24VDC 122RPM 20:1 ratio (consisting of) . . . . . . . .
. . . . KEY, woodruff .118 x .380 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . WASHER, wave .405 ID x .740 OD . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . RING, rtng ext .394 shaft x . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . FITTING, hose brs barbed M 3/16tbg . . . . . . . . . . . . . . . . . . . . . . . . .
. . SCREW, .375−16 x 1.25hexhd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . WASHER, flat stl SAE .312 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . KNOB, plstc T 1.000 lg x .312-18 x 2.000 bar . . . . . . . . . . . . . . . . . .
. . CARRIER, drive roll w/components . . . . . . . . . . . . . . . . . . . . . . . . . .
. . SCREW, M 4−.7 x 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . SCREW, M 6−1.0 x 20 soc hd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . WASHER, flat .250 ID x .437 OD . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . BUSHING, motor mtg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . WASHER, flat .438 ID X 1.00 OD . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . WASHER, lock .380 ID X .683 OD . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . GUIDE, wire inlet .023/.025 & .030-.035 wire . . . . . . . . . . . . . . . . . .
. . GUIDE, wire inlet .045 wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . GUIDE, anti-wear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . ROLL, drive V groove .023 wire
. . ROLL, drive V groove .030 wire
. . ROLL, drive V groove .035 wire
. . ROLL, drive V groove .045 wire
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
2
1
1
1
1
3
3
3
1
1
1
1
1
*Recommended Spare Parts.
♦OPTIONAL
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-1311 Page 29
. Hardware is common and
4
not available unless listed.
3
2
1
5
6
18
17
16
15
7
14
13
12
11
10
9
8
ST-802 288
Figure 6-4. Panel, Rear w/Components
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 6-4. Panel, Rear w/Components (Fig 6-1 Item 7)
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
...................
...................
...................
...................
...................
...................
...................
. . . . . . SR1 . . . . . . . .
...................
. . . . . D3, D4 . . . . . . .
. . . . . C1−C4 . . . . . . .
...................
. . . . . . TP1 . . . . . . . .
...................
...................
. . . . . D1, D2 . . . . . . .
. . . . . . FM1 . . . . . . . .
...................
OM-1311 Page 30
116 996
143 810
169 654
602 387
605 227
178 126
152 627
152 742
152 862
037 957
048 420
026 947
171 600
605 886
605 884
037 956
148 808
150 783
. . VALVE, 115 VAC 2way . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . BRACKET, support tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CHAIN, cyl racks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . NUT, 750−14 knurled 1.68 dia x .41 h . . . . . . . . . . . . . . . . . . . . . . . .
. . CONNECTOR, clamp cable .690/1.070 . . . . . . . . . . . . . . . . . . . . . . .
. . BRACKET, mtg windtunnel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . RECTIFIER, si diode (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . GROMMET, SCR .250 panel hole .3 . . . . . . . . . . . . . . . . . . . . . . . .
. . . . DIODE, rect 275A 300V RP DO-9 . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . CAPACITOR, cer disc .01u . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . STAND-OFF, INSLU .250-20 X 1.0 . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . THERMOSTAT, NC open 230F . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . WASHER, tooth .769 ID x 1.24 OD . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . NUT, .750-16 1.12 hex .44H stl plated . . . . . . . . . . . . . . . . . . . . . .
. . . . DIODE, rect 275A 300V SP DO-9 . . . . . . . . . . . . . . . . . . . . . . . . . .
. . MOTOR, fan 230V 50/60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . BLADE, fan 9.00 5wg 39 degree . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
1
1
1
1
1
8
2
4
2
1
4
4
2
1
1
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
. Hardware is common and
not available unless listed.
7
9
8
6
5
4
3
10
2
1
11
15
14
ST-802 287
13
12
Figure 6-5. Panel, Front w/Components
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 6-5. Panel, Front w/Components (Fig 6-1 Item 19)
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
1 . . . . . . . . . . . . 148 956 . .
2 . . . . . . . . . . . . 097 924 . .
3 . . . . . . . . . . . . 171 639 . .
4 . . . . . . . . . . . . 155 418 . .
5 . . . . . R2 . . . 035 897 . .
6 . . . . . . . . . . . . 175 060 . .
7 . . . . . . . . . . . . 143 974 . .
8 . . . . . . . . . . . . 186 058 . .
9 . . . . . S2 . . . 153 197 . .
10 . . . RC1 . . . 048 282 . .
11 . . . . S1 . . . 128 755 . .
12 . . . . . . . . . . . . . . . . . . . . . .
13 . . . PL1 . . . 160 775 . .
14 . . . . . . . . . . . 144 127 . .
15 . . . . . . . . . . . 057 357 . .
HANDLE, switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KNOB, pointer 1.625 dia x .250 ID w/setscrew . . . . . . . . . . . . . . . . . . . . . . . . .
PLATE, control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PANEL, front control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
POTENTIOMETER, CP STD slot 1T 2W 1K linear . . . . . . . . . . . . . . . . . . . . .
PANEL, front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HANDLE, running gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
COVER, dust . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SWITCH, selector 6 position (when ordering this part, order 186058 also) .
RECEPTACLE W/SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SWITCH, tgl dpst 40 A 600 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NAMEPLATE (order by model and serial number) . . . . . . . . . . . . . . . . . . . . . .
LIGHT, ind wht lens 115 VAC high hat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
COVER, opening module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BUSHING, snap-in nyl .937 ID x 1.125 mtg hole . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
OM-1311 Page 31
. Hardware is common and
20
19
17
16
15
14
12
11
10
1
2
*Includes Item 18
3
4
28
5
18
6
7
8
9
13*
20
18
19
21
17
22
12
11
10
9
23
24
25
26
27
not available unless listed.
ST-800 792
Figure 6-6. Exploded View Of Gun
OM-1311 Page 32
Item
No.
Part
No.
Description
Quantity
Figure 6-6. Exploded View Of Gun (Fig 1 Item 20)
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
1
1
1
1
2
2
2
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
25
25
26
27
28
. . . ♦169 724
. . . ♦169 725
. . . . . 169 726
. . . ♦169 727
. . . ♦087 299
. . . . . 000 067
. . . ♦000 068
. . . ♦000 069
. . . . . 169 728
. . . . . 169 729
. . . . . 170 467
. . . . . 170 468
. . . . . 169 730
. . . . . 169 731
. . . . . 169 738
. . . . . 169 732
. . . . . 169 733
. . . . . 169 734
. . . . . 172 018
. . . . . 169 735
. . . . . 169 742
. . . . . 169 743
. . . . . 170 469
. . . . . 169 746
. . . . . 169 737
. . . . . 169 741
. . . . . 169 736
. . . . . 172 565
. . . . . 173 521
. . . . . 079 974
. . . ♦172 257
. . . . . 172 258
. . . ♦172 259
. . . . . 079 975
. . . . . 169 723
. . . . . 169 739
. . NOZZLE, slip type .500 orf .125 recess . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . NOZZLE, slip type .625 orf .125 recess . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . NOZZLE, slip type .625 orf flush . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . NOZZLE, slip type .625 orf .125 stickout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . TIP, contact scr .023 wire x 1.125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . TIP, contact scr .030 wire x 1.125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . TIP, contact scr .035 wire x 1.125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . TIP, contact scr .045 wire x 1.125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . ADAPTER, contact tip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . ADAPTER, nozzle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . RING, retaining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . O-RING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . WASHER, shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . TUBE, head . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . NUT, locking handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . NUT, jam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CONNECTOR, cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . NUT, connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . M25 UNICABLE CLAMP KIT, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . CLIP, compression . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . TUBE, support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . CLAMP, inner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . CLAMP, jacket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . CONNECTOR, switch lead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . HANDLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . STRAIN RELIEF, cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . BLOCK, terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CABLE, pwr 21 in 18ga 2/c . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CONNECTOR, feeder (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . O-RING, .500 ID x .103CS rbr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . KIT, liner monocoil .023/.025 wire x 15ft (consisting of) . . . . . . . . . . . . . . . . . . . . . . . .
. . KIT, liner monocoil .030/.035 wire x 15ft (consisting of) . . . . . . . . . . . . . . . . . . . . . . . .
. . KIT, liner monocoil .035/.045 wire x 15ft (consisting of) . . . . . . . . . . . . . . . . . . . . . . . .
. . . . O-RING, .187 ID x .103CS rbr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . GUIDE, outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . SWITCH, trigger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
1
2
2
2
2
1
1
1
1
1
1
2
2
2
2
2
1
1
1
1
2
2
2
1
1
1
2
1
1
1
1
1
1
♦OPTIONAL
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-1311 Page 33
Effective January 1, 1999
(Equipment with a serial number preface of “KK” or newer)
Warranty Questions?
Call
1-800-4-A-MILLER
for your local
Miller distributor.
Your distributor also gives
you ...
Service
You always get the fast,
reliable response you
need. Most replacement
parts can be in your
hands in 24 hours.
Support
Need fast answers to the
tough welding questions?
Contact your distributor.
The expertise of the
distributor and Miller is
there to help you, every
step of the way.
This limited warranty supersedes all previous Miller warranties and is exclusive with no other
guarantees or warranties expressed or implied.
LIMITED WARRANTY − Subject to the terms and conditions
below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants
to its original retail purchaser that new Miller equipment sold
after the effective date of this limited warranty is free of defects
in material and workmanship at the time it is shipped by Miller.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS.
*
APT, ZIPCUT & PLAZCUT Model Plasma Cutting
Torches
*
Remote Controls
*
Accessory Kits
*
Replacement Parts (No labor)
*
Spoolmate 185
Within the warranty periods listed below, Miller will repair or
replace any warranted parts or components that fail due to
such defects in material or workmanship. Miller must be
notified in writing within thirty (30) days of such defect or
failure, at which time Miller will provide instructions on the
warranty claim procedures to be followed.
Miller’s True Blue Limited Warranty shall not apply to:
1.
Items furnished by Miller, but manufactured by others,
such as engines or trade accessories. These items are
covered by the manufacturer’s warranty, if any.
Miller shall honor warranty claims on warranted equipment
listed below in the event of such a failure within the warranty
time periods. All warranty time periods start on the date that
the equipment was delivered to the original retail purchaser, or
one year after the equipment is sent to a North American
distributor or eighteen months after the equipment is sent to an
International distributor.
2.
Consumable components; such as contact tips, cutting
nozzles, contactors, brushes, slip rings, relays or parts
that fail due to normal wear.
3.
Equipment that has been modified by any party other
than Miller, or equipment that has been improperly
installed, improperly operated or misused based upon
industry standards, or equipment which has not had
reasonable and necessary maintenance, or equipment
which has been used for operation outside of the
specifications for the equipment.
1.
5 Years Parts − 3 Years Labor
*
*
2.
3.
Original main power rectifiers
Inverters (input and output rectifiers only)
3 Years — Parts and Labor
*
*
Transformer/Rectifier Power Sources
Plasma Arc Cutting Power Sources
*
*
Semi-Automatic and Automatic Wire Feeders
Inverter Power Supplies
*
*
Intellitig
Engine Driven Welding Generators
(NOTE: Engines are warranted separately by the
engine manufacturer.)
1 Year — Parts and Labor
*
Motor Driven Guns (w/exception of Spoolmate
185)
*
*
Process Controllers
Positioners and Controllers
*
*
Automatic Motion Devices
Robots
*
*
IHPS Power Sources
Water Coolant Systems
*
*
*
HF Units
Grids
Spot Welders
*
*
Load Banks
SDX Transformers
*
*
Miller Cyclomatic Equipment
Running Gear/Trailers
*
Plasma Cutting Torches (except APT, ZIPCUT &
PLAZCUT Models)
*
*
Deutz Engines (outside North America)
Field Options
(NOTE: Field options are covered under True
Blue for the remaining warranty period of the
product they are installed in, or for a minimum of
one year — whichever is greater.)
4.
6 Months — Batteries
5.
90 Days — Parts
*
MIG Guns/TIG Torches
MILLER PRODUCTS ARE INTENDED FOR PURCHASE
AND USE BY COMMERCIAL/INDUSTRIAL USERS AND
PERSONS TRAINED AND EXPERIENCED IN THE USE
AND MAINTENANCE OF WELDING EQUIPMENT.
In the event of a warranty claim covered by this warranty, the
exclusive remedies shall be, at Miller’s option: (1) repair; or (2)
replacement; or, where authorized in writing by Miller in
appropriate cases, (3) the reasonable cost of repair or
replacement at an authorized Miller service station; or (4)
payment of or credit for the purchase price (less reasonable
depreciation based upon actual use) upon return of the goods
at customer’s risk and expense. Miller’s option of repair or
replacement will be F.O.B., Factory at Appleton, Wisconsin, or
F.O.B. at a Miller authorized service facility as determined by
Miller. Therefore no compensation or reimbursement for
transportation costs of any kind will be allowed.
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR
DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF
PROFIT), WHETHER BASED ON CONTRACT, TORT OR
ANY OTHER LEGAL THEORY.
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN
AND ANY IMPLIED WARRANTY, GUARANTY OR
REPRESENTATION AS TO PERFORMANCE, AND ANY
REMEDY FOR BREACH OF CONTRACT TORT OR ANY
OTHER LEGAL THEORY WHICH, BUT FOR THIS
PROVISION,
MIGHT
ARISE
BY
IMPLICATION,
OPERATION OF LAW, CUSTOM OF TRADE OR COURSE
OF DEALING, INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR PARTICULAR
PURPOSE, WITH RESPECT TO ANY AND ALL
EQUIPMENT FURNISHED BY MILLER IS EXCLUDED AND
DISCLAIMED BY MILLER.
Some states in the U.S.A. do not allow limitations of how long
an implied warranty lasts, or the exclusion of incidental,
indirect, special or consequential damages, so the above
limitation or exclusion may not apply to you. This warranty
provides specific legal rights, and other rights may be
available, but may vary from state to state.
In Canada, legislation in some provinces provides for certain
additional warranties or remedies other than as stated herein,
and to the extent that they may not be waived, the limitations
and exclusions set out above may not apply. This Limited
Warranty provides specific legal rights, and other rights may
be available, but may vary from province to province.
miller_warr 1/99
Owner’s Record
Please complete and retain with your personal records.
Model Name
Serial/Style Number
Purchase Date
(Date which equipment was delivered to original customer.)
Distributor
Address
City
State
Zip
Resources Available
Always provide Model Name and Serial/Style Number.
Contact your Distributor for:
To locate distributor nearest you call
1-800-4-A-Miller.
Welding Supplies and Consumables
Options and Accessories
Personal Safety Equipment
Service and Repair
Miller Electric Mfg. Co.
An Illinois Tool Works Company
1635 West Spencer Street
Appleton, WI 54914 USA
Replacement Parts
Training (Schools, Videos, Books)
International Headquarters−USA
USA Phone: 920-735-4505 Auto-Attended
USA & Canada FAX: 920-735-4134
International FAX: 920-735-4125
Technical Manuals (Servicing Information
and Parts)
Circuit Diagrams
European Headquarters −
United Kingdom
Phone: 44 (0) 1204-593493
FAX: 44 (0) 1204-598066
Welding Process Handbooks
www.MillerWelds.com
Contact the Delivering Carrier for:
File a claim for loss or damage during
shipment.
For assistance in filing or settling claims,
contact your distributor and/or equipment
manufacturer’s Transportation Department.
PRINTED IN USA
 1999 Miller Electric Mfg. Co.
9/98
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising