Miller | MG026708D | Owner Manual | Miller PDM1 400A, 1000A SHUNT FILTERS User manual

Miller PDM1 400A, 1000A SHUNT FILTERS User manual
OM-273451B
2016−01
Processes
Induction Heating
Multiprocess Welding
Submerged Arc (SAW) Welding
Electroslag (ESW) Welding
Description
Portable Data Recorder
PDM1 400A, 1000A
Shunt Filters
400A
1000A/2000A
From Miller to You
Thank you and congratulations on choosing Miller. Now you can get the
job done and get it done right. We know you don’t have time to do it any
other way.
That’s why when Niels Miller first started building arc welders in 1929,
he made sure his products offered long-lasting value and superior quality.
Like you, his customers couldn’t afford anything less. Miller products had
to be more than the best they could be. They had to be the best you could
buy.
Today, the people that build and sell Miller products continue the
tradition. They’re just as committed to providing equipment and service
that meets the high standards of quality and value established in 1929.
This Owner’s Manual is designed to help you get the most out of your
Miller products. Please take time to read the Safety precautions. They will
help you protect yourself against potential hazards on the worksite. We’ve
made installation and operation quick and easy. With Miller you can
count on years of reliable service with proper maintenance. And if for
some reason the unit needs repair, there’s a Troubleshooting section that
will help you figure out what the problem is. The parts list will then help
you to decide which exact part you may need to fix the problem.
Warranty and service information for your particular model are also
provided.
Miller Electric manufactures a full line of
welders and welding related equipment. For
information on other quality Miller products, contact your local Miller
distributor to receive the latest full line catalog or individual catalog sheets.
Working as hard as you do
− every power source from
Miller is backed by the most
hassle-free warranty in the
business.
TABLE OF CONTENTS
SECTION 1 −SAFETY PRECAUTIONS FOR GTAW TORCHES − READ BEFORE USING . . . . . . . . . . . . . .
1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Proposition 65 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1. Signification des symboles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2. Dangers relatifs au soudage à l’arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3. Proposition californienne 65 Avertissements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-4. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-5. Informations relatives aux CEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 − SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2. Duty Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 4 − INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-1. Required Torch Parts And Torch Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. International Style Connector Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3. Connecting Torch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 5 − MAINTENANCE & TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2. Gas And/Or Water Hose Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-3. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 − SELECTING AND PREPARING A TUNGSTEN
FOR DC OR AC WELDING WITH INVERTER MACHINES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-1. Selecting Tungsten Electrode (Wear Clean Gloves To Prevent Contamination Of Tungsten) . . . . . . .
6-2. Preparing Tungsten Electrode For DC Electrode Negative (DCEN) Welding
Or AC Welding With Inverter Machines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 7 − GUIDELINES FOR TIG WELDING (GTAW) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 8 − PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARRANTY
1
1
1
2
2
2
3
3
3
4
4
5
7
7
7
8
8
8
9
12
12
12
13
15
15
15
16
18
DECLARATION OF CONFORMITY
for European Community (CE marked) products.
ITW Welding Italy S.r.l Via Privata Iseo 6/E, 20098 San Giuliano M.se, (MI) Italy declares that the prod­
uct(s) identified in this declaration conform to the essential requirements and provisions of the stat­
ed Council Directive(s) and Standard(s).
Product/Apparatus Identification:
Product
Stock Number
PDM1 SHUNT FILTER 400A
PDM1 SHUNT FILTER 1000A
028069184
028069185
Council Directives:
·2006/95/EC Low Voltage
·2004/108/EC Electromagnetic Compatibility
·2011/65/EU Restriction of the use of certain hazardous substances in electrical and electronic equipment
Standards:
·IEC 61010-1:2010. Safety requirements for electrical equipment for measurement, control, and laboratory use- Part
1: General requirements
·IEC 61326-1:2012. Electrical equipment for measurement, control and laboratory use -EMC requirementsPart 1: General requirements
EU Signatory:
October 9th, 2015
___________________________________________________________________________________
Massimigliano Lavarini
Date of Declaration
ITW WELDING ITALY PRODUCTION MANAGER
956 172 209
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING
som 2015−09
7
Protect yourself and others from injury — read, follow, and save these important safety precautions and operating instructions.
1-1. Symbol Usage
DANGER! − Indicates a hazardous situation which, if
not avoided, will result in death or serious injury. The
possible hazards are shown in the adjoining symbols
or explained in the text.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury. The possible
hazards are shown in the adjoining symbols or explained in the text.
NOTICE − Indicates statements not related to personal injury.
. Indicates special instructions.
This group of symbols means Warning! Watch Out! ELECTRIC
SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult symbols and related instructions below for necessary actions to avoid the
hazards.
1-2. Arc Welding Hazards
The symbols shown below are used throughout this manual
to call attention to and identify possible hazards. When you
see the symbol, watch out, and follow the related instructions
to avoid the hazard. The safety information given below is
only a summary of the more complete safety information
found in the Safety Standards listed in Section 1-5. Read and
follow all Safety Standards.
Only qualified persons should install, operate, maintain, and
repair this unit.
During operation, keep everybody, especially children, away.
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shocks
or severe burns. The electrode and work circuit is
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also
live when power is on. In semiautomatic or automatic
wire welding, the wire, wire reel, drive roll housing,
and all metal parts touching the welding wire are
electrically live. Incorrectly installed or improperly
grounded equipment is a hazard.
D Do not touch live electrical parts.
D Wear dry, hole-free insulating gloves and body protection.
D Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.
D Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
D Use AC output ONLY if required for the welding process.
D If AC output is required, use remote output control if present on
unit.
D Additional safety precautions are required when any of the following electrically hazardous conditions are present: in damp
locations or while wearing wet clothing; on metal structures such
as floors, gratings, or scaffolds; when in cramped positions such
as sitting, kneeling, or lying; or when there is a high risk of unavoidable or accidental contact with the workpiece or ground. For these
conditions, use the following equipment in order presented: 1) a
semiautomatic DC constant voltage (wire) welder, 2) a DC manual
(stick) welder, or 3) an AC welder with reduced open-circuit voltage. In most situations, use of a DC, constant voltage wire welder
is recommended. And, do not work alone!
D Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
D Properly install, ground, and operate this equipment according to
its Owner’s Manual and national, state, and local codes.
D Always verify the supply ground − check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
grounded receptacle outlet.
D When making input connections, attach proper grounding conductor first − double-check connections.
D Keep cords dry, free of oil and grease, and protected from hot metal
and sparks.
D Frequently inspect input power cord and ground conductor for
damage or bare wiring – replace immediately if damaged – bare
wiring can kill.
D Turn off all equipment when not in use.
D Do not use worn, damaged, undersized, or repaired cables.
D Do not drape cables over your body.
D If earth grounding of the workpiece is required, ground it directly
with a separate cable.
D Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
D Do not touch electrode holders connected to two welding machines at the same time since double open-circuit voltage will be
present.
D Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
D Wear a safety harness if working above floor level.
D Keep all panels and covers securely in place.
D Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
D Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
D Do not connect more than one electrode or work cable to any
single weld output terminal. Disconnect cable for process not in
use.
D Use GFCI protection when operating auxiliary equipment in damp
or wet locations.
SIGNIFICANT DC VOLTAGE exists in inverter welding power sources AFTER removal of input power.
D Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section
before touching any parts.
HOT PARTS can burn.
D Do not touch hot parts bare handed.
D Allow cooling period before working on
equipment.
D To handle hot parts, use proper tools and/or wear heavy, insulated welding gloves and clothing to prevent burns.
OM-273451 Page 1
FUMES AND GASES can be hazardous.
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health.
D Keep your head out of the fumes. Do not breathe the fumes.
D If inside, ventilate the area and/or use local forced ventilation at the
arc to remove welding fumes and gases. The recommended way
to determine adequate ventilation is to sample for the composition
and quantity of fumes and gases to which personnel are exposed.
D If ventilation is poor, wear an approved air-supplied respirator.
D Read and understand the Safety Data Sheets (SDSs) and the
manufacturer’s instructions for adhesives, coatings, cleaners,
consumables, coolants, degreasers, fluxes, and metals.
D Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watchperson nearby. Welding fumes and gases can displace air and
lower the oxygen level causing injury or death. Be sure the breathing air is safe.
D Do not weld in locations near degreasing, cleaning, or spraying operations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.
D Do not weld on coated metals, such as galvanized, lead, or
cadmium plated steel, unless the coating is removed from the weld
area, the area is well ventilated, and while wearing an air-supplied
respirator. The coatings and any metals containing these elements
can give off toxic fumes if welded.
ARC RAYS can burn eyes and skin.
Arc rays from the welding process produce intense
visible and invisible (ultraviolet and infrared) rays
that can burn eyes and skin. Sparks fly off from the
weld.
D Wear an approved welding helmet fitted with a proper shade of
filter lenses to protect your face and eyes from arc rays and
sparks when welding or watching (see ANSI Z49.1 and Z87.1
listed in Safety Standards).
D Wear approved safety glasses with side shields under your
helmet.
D Use protective screens or barriers to protect others from flash,
glare and sparks; warn others not to watch the arc.
D Wear body protection made from durable, flame−resistant material (leather, heavy cotton, wool). Body protection includes
oil-free clothing such as leather gloves, heavy shirt, cuffless
trousers, high shoes, and a cap.
WELDING can cause fire or explosion.
Welding on closed containers, such as tanks,
drums, or pipes, can cause them to blow up. Sparks
can fly off from the welding arc. The flying sparks, hot
workpiece, and hot equipment can cause fires and
burns. Accidental contact of electrode to metal objects can cause
sparks, explosion, overheating, or fire. Check and be sure the area is
safe before doing any welding.
D Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
D Do not weld where flying sparks can strike flammable material.
D Protect yourself and others from flying sparks and hot metal.
D Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
D Watch for fire, and keep a fire extinguisher nearby.
D Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
D Do not weld on containers that have held combustibles, or on
closed containers such as tanks, drums, or pipes unless they are
properly prepared according to AWS F4.1 and AWS A6.0 (see
Safety Standards).
D Do not weld where the atmosphere can contain flammable dust,
gas, or liquid vapors (such as gasoline).
D Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly
unknown paths and causing electric shock, sparks, and fire
hazards.
D Do not use welder to thaw frozen pipes.
OM-273451 Page 2
D Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
D Wear body protection made from durable, flame−resistant material
(leather, heavy cotton, wool). Body protection includes oil-free
clothing such as leather gloves, heavy shirt, cuffless trousers, high
shoes, and a cap.
D Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.
D After completion of work, inspect area to ensure it is free of sparks,
glowing embers, and flames.
D Use only correct fuses or circuit breakers. Do not oversize or bypass them.
D Follow requirements in OSHA 1910.252 (a) (2) (iv) and NFPA 51B
for hot work and have a fire watcher and extinguisher nearby.
D Read and understand the Safety Data Sheets (SDSs) and the
manufacturer’s instructions for adhesives, coatings, cleaners,
consumables, coolants, degreasers, fluxes, and metals.
FLYING METAL or DIRT can injure eyes.
D Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool,
they can throw off slag.
D Wear approved safety glasses with side
shields even under your welding helmet.
BUILDUP OF GAS can injure or kill.
D Shut off compressed gas supply when not in use.
D Always ventilate confined spaces or use
approved air-supplied respirator.
ELECTRIC AND MAGNETIC FIELDS (EMF)
can affect Implanted Medical Devices.
D Wearers of Pacemakers and other Implanted
Medical Devices should keep away.
D Implanted Medical Device wearers should consult their doctor
and the device manufacturer before going near arc welding, spot
welding, gouging, plasma arc cutting, or induction heating
operations.
NOISE can damage hearing.
Noise from some processes or equipment can
damage hearing.
D Wear approved ear protection if noise level is high.
CYLINDERS can explode if damaged.
Compressed gas cylinders contain gas under high
pressure. If damaged, a cylinder can explode. Since
gas cylinders are normally part of the welding
process, be sure to treat them carefully.
D Protect compressed gas cylinders from excessive heat, mechanical shocks, physical damage, slag, open flames, sparks, and arcs.
D Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
D Keep cylinders away from any welding or other electrical circuits.
D Never drape a welding torch over a gas cylinder.
D Never allow a welding electrode to touch any cylinder.
D Never weld on a pressurized cylinder − explosion will result.
D Use only correct compressed gas cylinders, regulators, hoses,
and fittings designed for the specific application; maintain them
and associated parts in good condition.
D Turn face away from valve outlet when opening cylinder valve. Do
not stand in front of or behind the regulator when opening the valve.
D Keep protective cap in place over valve except when cylinder is in
use or connected for use.
D Use the right equipment, correct procedures, and sufficient number of persons to lift and move cylinders.
D Read and follow instructions on compressed gas cylinders,
associated equipment, and Compressed Gas Association (CGA)
publication P-1 listed in Safety Standards.
1-3. Additional Symbols For Installation, Operation, And Maintenance
FIRE OR EXPLOSION hazard.
D Do not install or place unit on, over, or near
combustible surfaces.
D Do not install unit near flammables.
D Do not overload building wiring − be sure power supply system is
properly sized, rated, and protected to handle this unit.
FALLING EQUIPMENT can injure.
D Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
D Use equipment of adequate capacity to lift and
support unit.
D If using lift forks to move unit, be sure forks are long enough to
extend beyond opposite side of unit.
D Keep equipment (cables and cords) away from moving vehicles
when working from an aerial location.
D Follow the guidelines in the Applications Manual for the Revised
NIOSH Lifting Equation (Publication No. 94−110) when manually lifting heavy parts or equipment.
OVERUSE can cause OVERHEATING
MOVING PARTS can injure.
D Keep away from moving parts such as fans.
D Keep all doors, panels, covers, and guards
closed and securely in place.
D Have only qualified persons remove doors, panels, covers, or
guards for maintenance and troubleshooting as necessary.
D Reinstall doors, panels, covers, or guards when maintenance is
finished and before reconnecting input power.
READ INSTRUCTIONS.
D Read and follow all labels and the Owner’s
Manual carefully before installing, operating, or
servicing unit. Read the safety information at
the beginning of the manual and in each
section.
D Use only genuine replacement parts from the manufacturer.
D Perform installation, maintenance, and service according to the
Owner’s Manuals, industry standards, and national, state, and
local codes.
D Allow cooling period; follow rated duty cycle.
D Reduce current or reduce duty cycle before
starting to weld again.
D Do not block or filter airflow to unit.
H.F. RADIATION can cause interference.
FLYING SPARKS can injure.
D Wear a face shield to protect eyes and face.
D Shape tungsten electrode only on grinder with
proper guards in a safe location wearing proper
face, hand, and body protection.
D
D Sparks can cause fires — keep flammables away.
D
STATIC (ESD) can damage PC boards.
D Put on grounded wrist strap BEFORE handling
boards or parts.
D Use proper static-proof bags and boxes to
store, move, or ship PC boards.
D
D
D High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communications equipment.
D Have only qualified persons familiar with
electronic equipment perform this installation.
The user is responsible for having a qualified electrician promptly correct any interference problem resulting from the installation.
If notified by the FCC about interference, stop using the
equipment at once.
Have the installation regularly checked and maintained.
Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.
MOVING PARTS can injure.
ARC WELDING can cause interference.
D Keep away from moving parts.
D Keep away from pinch points such as drive
rolls.
WELDING WIRE can injure.
D Do not press gun trigger until instructed to do
so.
D Do not point gun toward any part of the body,
other people, or any metal when threading
welding wire.
BATTERY EXPLOSION can injure.
D Do not use welder to charge batteries or jump
start vehicles unless it has a battery charging
feature designed for this purpose.
D
D
D
D
D Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.
D Be sure all equipment in the welding area is
electromagnetically compatible.
To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
Locate welding operation 100 meters from any sensitive electronic equipment.
Be sure this welding machine is installed and grounded
according to this manual.
If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables,
using line filters, or shielding the work area.
OM-273451 Page 3
1-4. California Proposition 65 Warnings
Welding or cutting equipment produces fumes or gases
which contain chemicals known to the State of California to
cause birth defects and, in some cases, cancer. (California
Health & Safety Code Section 25249.5 et seq.)
This product contains chemicals, including lead, known to
the state of California to cause cancer, birth defects, or other
reproductive harm. Wash hands after use.
1-5. Principal Safety Standards
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
is available as a free download from the American Welding Society at
http://www.aws.org or purchased from Global Engineering Documents
(phone: 1-877-413-5184, website: www.global.ihs.com).
Safe Practices for the Preparation of Containers and Piping for Welding
and Cutting, American Welding Society Standard AWS F4.1, from Global Engineering Documents (phone: 1-877-413-5184, website:
www.global.ihs.com).
Safe Practices for Welding and Cutting Containers that have Held Combustibles, American Welding Society Standard AWS A6.0, from Global
Engineering Documents (phone: 1-877-413-5184,
website: www.global.ihs.com).
National Electrical Code, NFPA Standard 70, from National Fire Protection Association, Quincy, MA 02269 (phone: 1-800-344-3555, website:
www.nfpa.org and www. sparky.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 14501 George Carter Way, Suite
103, Chantilly, VA 20151 (phone: 703-788-2700, website:www.cganet.com).
Safety in Welding, Cutting, and Allied Processes, CSA Standard
W117.2, from Canadian Standards Association, Standards Sales, 5060
Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5NS
(phone: 800-463-6727, website: www.csagroup.org).
Safe Practice For Occupational And Educational Eye And Face Protection, ANSI Standard Z87.1, from American National Standards Institute,
25 West 43rd Street, New York, NY 10036 (phone: 212-642-4900, website: www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, from National Fire Protection Association,
Quincy, MA 02269 (phone: 1-800-344-3555, website: www.nfpa.org).
OSHA, Occupational Safety and Health Standards for General Industry, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,
and Part 1926, Subpart J, from U.S. Government Printing Office, Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954
(phone: 1-866-512-1800) (there are 10 OSHA Regional Offices—
phone for Region 5, Chicago, is 312-353-2220, website:
www.osha.gov).
Applications Manual for the Revised NIOSH Lifting Equation, The National Institute for Occupational Safety and Health (NIOSH), 1600
Clifton Rd, Atlanta, GA 30329-4027 (phone: 1-800-232-4636, website:
www.cdc.gov/NIOSH).
1-6. EMF Information
Electric current flowing through any conductor causes localized electric
and magnetic fields (EMF). The current from arc welding (and allied processes including spot welding, gouging, plasma arc cutting, and
induction heating operations) creates an EMF field around the welding
circuit. EMF fields can interfere with some medical implants, e.g. pacemakers. Protective measures for persons wearing medical implants
have to be taken. For example, restrict access for passers−by or conduct individual risk assessment for welders. All welders should use the
following procedures in order to minimize exposure to EMF fields from
the welding circuit:
1. Keep cables close together by twisting or taping them, or using a
cable cover.
2. Do not place your body between welding cables. Arrange cables
to one side and away from the operator.
3. Do not coil or drape cables around your body.
OM-273451 Page 4
4. Keep head and trunk as far away from the equipment in the
welding circuit as possible.
5. Connect work clamp to workpiece as close to the weld as
possible.
6. Do not work next to, sit or lean on the welding power source.
7. Do not weld whilst carrying the welding power source or wire
feeder.
About Implanted Medical Devices:
Implanted Medical Device wearers should consult their doctor and the
device manufacturer before performing or going near arc welding, spot
welding, gouging, plasma arc cutting, or induction heating operations.
If cleared by your doctor, then following the above procedures is recommended.
SECTION 2 − DEFINITIONS
2-1. Additional Safety Symbols And Definitions
Warning! Watch Out! There are possible hazards as shown by the symbols.
Safe1 2012−05
Do not remove or paint over (cover) the label.
Safe20 2012−05
Do not discard product (where applicable) with general waste.
Reuse or recycle Waste Electrical and Electronic Equipment (WEEE) by disposing at a designated collection
facility.
Contact your local recycling office or your local distributor for further information.
Safe37 2012−05
Disconnect input plug or power before working on machine.
Safe5 2012−05
?
?
V
A
Consult rating label for input power requirements.
Safe34 2012−05
Become trained and read the instructions before working on the
machine or welding.
Safe40 2012−05
2-2. Miscellaneous Symbols And Definitions
V
A
Voltage
Amperage
Directional
Current Flow
Indicator
OM-273451 Page 5
SECTION 3 − SPECIFICATIONS
3-1. Description
The PDM1 Shunt Filter allows the
system to be connected directly for
all welding processes. It consists of
a Hall−Effect clamp current sensor
and a probe device voltage sensor.
The current sensor must be installed in order to ensure that the
current flows according to the directional indicator in the probe. PDM1
shunt filter is supplied with:
• Impact resistant flame retardant
case protecting components
from moisture, dust, and other
contaminants
• 70mm2 cable (400A shunt only)
to connect the Shunt filter to the
welding power source
• 5 pin receptacle to connect the
shunt filter to the Arc Data Pro
PDM1 (A 5-pin cable is not supplied)
• Positive weld output stud (400A
model only)
• Negative weld output stud (400A
model only)
956172206_1-A
3-2. Specifications
Parameters
Arc Current
Model
Input
Voltage
400A Shunt Filter
Primary Nominal
Current RMS
Arc Voltage
IPN (A)
Primary Current
Measuring Range
IPM (A)
400A
±1000A
±15V
1000A Shunt Filter
1000A
±2000A
Dimensions
Weight
(mm)
(kg)
VPN (V)
Primary Voltage
Measuring Range
VPM (V)
L:280
2.97
150V
±225V
W:123
Primary Nominal
Voltage RMS
H:246
2.25
Operating temperature range: -25 − +85°C
Overall accuracy (% of nominal value): ±0.5
OM-273451 Page 6
3-3. Process Table
Process
(+) Positive Lead
(-) Negative Lead
Shunt Filter Type
MIG (GMAW)
Electrode
Work
400A
TIG (GTAW)
Work
Electrode
400A
Flux Cored (FCAW)
Electrode
Work
400A
Stick (SMAW)
Electrode
Work
400A
Sub Arc Welding (SAW)
Electrode
Work
1000A
Electroslag (ESW)
Electrode
Work
2000A
SECTION 4 − INSTALLATION
4-1. Installing A 400A Shunt Filter For the Stick Process
1
(+) Positive Weld Output
Terminal
Connect electrode holder to power
source positive weld output terminal.
2
(-) Negative Weld Output
Terminal
Connect cable from 400A shunt filter
to power source negative weld output terminal. Connect work clamp to
shunt filter weld output receptacle.
3
+/- Volt Sense Cable
Connect volt sense cables to positive and negative weld output terminal.
21
. Connect volt sense cable direct-
4
ly to workpiece.
5
3
4
Shunt Filter
5
5-Pin Receptacle Cable
Connect 5−pin cable to shunt filter
and Arc Data Pro PDM1. Ref. TA/TV
receptacle.
Turn power on. Allow time for unit
complete its start up cycle.
956172206_2-B
OM-273451 Page 7
4-2. Installing A 400A Shunt Filter For the TIG/TIG-HF Process
1
(+) Positive Weld Output Terminal
Connect cable from 400A shunt filter to
power source positive weld output terminal. Connect work clamp to shunt filter weld output receptacle.
2
(-) Negative Weld Output
Terminal
Connect TIG torch to power source
negative weld output terminal.
4
3
Shunt Filter
4
5-Pin Receptacle Cable
Connect 5−pin cable to shunt filter and
Arc Data Pro PDM1. Ref. TA/TV receptacle.
5
5
+/- Volt Sense Cable
Connect volt sense cables to positive
and negative weld output terminals on
welding power source.
3
. Connect volt sense cable directly
to workpiece.
21
Turn power on. Allow time for unit complete its start up cycle.
956172206_3-B
4-3. Installing A 400A Shunt Filter For the MIG Process
1
(+) Positive Weld Output Terminal
Connect MIG torch to power source
positive weld output terminal.
2
(-) Negative Weld Output Terminal
Connect work clamp to power source
negative weld output terminal.
21
3
4
Shunt Filter
Connect cable from 400A shunt filter to
power source negative weld output terminal. Connect work clamp to shunt filter weld output receptacle.
5
3
4
5-Pin Receptacle Cable
Connect 5−pin receptacle cable to
shunt filter and Arc Data Pro PDM1.
Ref. TA/TV receptacle.
5
+/- Volt Sense Cable
Connect volt sense cables to positive
and negative weld output terminals on
welding power source.
. Connect volt sense cable directly
to workpiece.
Turn power on. Allow time for unit complete its start up cycle.
956172206_4-B
OM-273451 Page 8
4-4. Installing A 1000A/2000A Shunt Filter For the SAW/ESW Processes
1
(+) Positive Weld Output Cable
Connect torch to power source positive weld output terminal.
2
(-) Negative Weld Output Terminal
Slide the work clamp cable through
the 1000A shunt filter probe. Connect work clamp to power source
negative weld output terminal.
3
4
+/- Volt Sense Cable
Connect volt sense cables to positive and negative weld output terminals on welding power source.
1
. Connect volt sense cable direct-
3
ly to workpiece.
4
Shunt Filter
Turn power on. Allow time for unit
complete its start up cycle.
2
956172206_5-B
4-5.
Amperage/Voltage 5-Pin Receptacle Information
Socket
4
1
5
2
3
Ref. 956172203_7-A
Socket Information
1
+15 volts DC
2
-15 volts DC
3
Voltage Signal
4
Common GND
5
Amperage Signal
OM-273451 Page 9
SECTION 5 − OPERATION
5-1. Controls
1
Power Cable
Connect cable to appropriate weld
output terminal on welding power
source.
400A Shunt Filter
2
2
5-Pin Receptacle
Connect 5-pin cable to receptacle on
Arc Data Pro PDM1.
3
Weld Output Receptacle
Connect welding torch.
4
+/- Volt Sense Cable
Connect volt sense cables to positive and negative weld output terminals on welding power source.
3
4
1
1
1000A/2000A Shunt Filter
2
956172203_6-A
OM-273451 Page 10
SECTION 6 − TROUBLESHOOTING
6-1. Troubleshooting
Trouble
Remedy
Volt/Amps displays on Arc Data Pro Check 5-pin plug for damage and loose wires.
PDM1 are not active, even though the
5-pin cable is connected to the 5-pin re- Clean all pins and sockets on 5-pin plug and receptacle. Make sure connection is tight and secure.
ceptacle on the shunt filter.
Check cable connections.
Have Factory Authorized Agent check unit and replace damaged parts.
Replace shunt filter.
Notes
OM-273451 Page 11
SECTION 7 − ELECTRICAL DIAGRAM
956172207-A
Figure 7-1. Circuit Diagram For 400A Shunt Filter
956172208-A
Figure 7-2. Circuit Diagram For 1000A/2000A Shunt Filter
OM-273451 Page 12
SECTION 8 − PARTS LIST
. Hardware is common and
not available unless listed.
5
4
3
6
7
8
9
2
1
10
11
956172206_7-B
Figure 8-1. Complete 400A Shunt Filter Assembly
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
8-1. Complete 400A Shunt Filter Assembly
. . . 1 . . . . . . . . . . . 050009140 . . Cable, Stud . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 2 . . . . . . . . . . . 656089048 . . Strain Relief, Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 3 . . . . . . . . . . . 656039017 . . Case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 4 . . . . . . . . . . . 056167006 . . Ferrite Core . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 5 . . . . . . . . . . . . . DVL 150 . . Transducer, Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 6 . . . . . . . . . . . 156018118 . . Nut . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 7 . . . . . . . . . . . 656089038 . . Strain Relief, Sense Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 8 . . . . . . . . . . . . . . 208967 . . RCPT Assy, TW LK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 9 . . . HD1 . . . . . . 182918 . . Transducer, Current 400A Module . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 10 . . . . . . . . . . . 356031004 . . Bus Bar, LEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 11 . . . . S1 . . . 056076279 . . RCPT, 5‐Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-273451 Page 13
. Hardware is common and
not available unless listed.
2
3
1
4
5
6
7
956172206_8-B
Figure 8-2. Complete 1000A/2000A Shunt Filter Assembly
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
8-2. Complete 1000A/2000A Shunt Filter Assembly
. . . 1 . . . . . . . . . . . 656039017 . . Case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 2 . . . . . . . . . . . . . DVL 150 . . Transducer, Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 3 . . . HD1 HOP1000−SB . . Transducer, Current 1000A Module . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 4 . . . . . . . . . . . 656089038 . . Strain relief, sense voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 5 . . . . . . . . . . . 156018118 . . Nut . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 6 . . . . . . . . . . . 056167006 . . Ferrite Core . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 7 . . . . . . . . . . . 056076279 . . RCPT, 5−pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-273451 Page 14
Warranty
Effective January 1, 2016
(Equipment with a serial number preface of MG or newer)
This limited warranty supersedes all previous ITW Welding Italy warranties and is exclusive with no other
guarantees or warranties expressed or implied.
LIMITED WARRANTY − Subject to the terms and conditions
below, ITW Welding Italy warrants to its original retail purchaser
that new equipment sold after the effective date of this limited
warranty is free of defects in material and workmanship at the
time it is shipped by ITW. THIS WARRANTY IS EXPRESSLY IN
LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING THE WARRANTIES OF MERCHANTABILITY
AND FITNESS.
Within the warranty periods listed below, ITW Welding Italy will
repair or replace any warranted parts or components that fail due
to such defects in material or workmanship. ITW Welding Italy
must be notified in writing within thirty (30) days of such defect or
failure, at which time ITW Welding Italy will provide instructions
on the warranty claim procedures to be followed. If notification is
submitted as an online warranty claim, the claim must include a
detailed description of the fault and the troubleshooting steps
taken to identify failed components and the cause of their failure.
ITW Welding Italy shall honor warranty claims on warranted
equipment listed below in the event of such a failure within the
warranty time periods. All warranty time periods start on the date
the equipment was delivered to the original retail purchaser or
twelve months after the equipment is shipped to a European
distributor or twelve months after the equipment is shipped to an
international distributor.
1.
1 Year — Parts and Labor Unless Specified
*
Data Monitor
*
Single Wire Subarc Torches
*
Tandem Wire Subarc Torches
*
Cladding Head Subarc/ESW Torches
*
Magnetic Steering Devices
*
Strip Spool Holders
*
Compressed Air Flux Feeders
*
Column and Boom
*
Inner Welding Beam
*
Rotary Table
*
Positioners and Controllers
*
Welding Trolley
ITW Welding Italy Limited Warranty shall not apply to:
1.
Consumable components; such as contact tips,
cutting nozzles, contactors, brushes, switches, slip
rings, relays or parts that fail due to normal wear.
2.
Items furnished by ITW Welding Italy, but manufactured by
others, such as engines or trade accessories. These items
are covered by the manufacturer’s warranty, if any.
3.
Equipment that has been modified by any party other than
the ITW Welding Italy, or equipment that has been
improperly installed, improperly operated or misused based
upon industry standards, or equipment which has not had
reasonable and necessary maintenance, or equipment
which has been used for operation outside of the
specifications for the equipment.
ITW Welding Italy’s PRODUCTS ARE INTENDED FOR
PURCHASE AND USE BY COMMERCIAL/INDUSTRIAL
USERS AND PERSONS TRAINED AND EXPERIENCED IN
THE USE AND MAINTENANCE OF WELDING EQUIPMENT.
In the event of a warranty claim covered by this warranty, the
exclusive remedies shall be, at ITW’s option: (1) repair; or (2)
replacement; or, where authorized in writing by ITW in
appropriate cases, (3) the reasonable cost of repair or
replacement at an authorized ITW service station; or (4)
payment of or credit for the purchase price (less reasonable
depreciation based upon actual use) upon return of the goods at
customer’s risk and expense. ITW’s option of repair or
replacement will be F.O.B., Factory at ITW Welding Italy Group
Europe. Therefore no compensation or reimbursement for
transportation costs of any kind will be allowed.
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE
REMEDIES. IN NO EVENT SHALL ITW BE LIABLE FOR
DIRECT,
INDIRECT,
SPECIAL,
INCIDENTAL
OR
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF
PROFIT), WHETHER BASED ON CONTRACT, TORT OR ANY
OTHER LEGAL THEORY.
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND
ANY
IMPLIED
WARRANTY,
GUARANTY
OR
REPRESENTATION AS TO PERFORMANCE, AND ANY
REMEDY FOR BREACH OF CONTRACT TORT OR ANY
OTHER LEGAL THEORY WHICH, BUT FOR THIS
PROVISION, MIGHT ARISE BY IMPLICATION, OPERATION
OF LAW, CUSTOM OF TRADE OR COURSE OF DEALING,
INCLUDING
ANY
IMPLIED
WARRANTY
OF
MERCHANTABILITY OR FITNESS FOR PARTICULAR
PURPOSE, WITH RESPECT TO ANY AND ALL EQUIPMENT
FURNISHED BY ITW Welding Italy IS EXCLUDED AND
DISCLAIMED BY ITW Welding Italy.
Milan EU brand 2016-01
Owner’s Record
Please complete and retain with your personal records.
Model Name
Serial/Style Number
Purchase Date
(Date which equipment was delivered to original customer.)
Distributor
Address
Country
Zip/Postal Code
For Service
Contact a DISTRIBUTOR or SERVICE AGENCY near you.
Always provide Model Name and Serial/Style Number.
Contact your Distributor for:
Welding Supplies and Consumables
Options and Accessories
Service and Repair
Replacement Parts
Owner’s Manuals
ITW Welding Italy S.r.l.
Contact the Delivering Carrier to:
File a claim for loss or damage during
shipment.
For assistance in filing or settling claims, contact
your distributor and/or equipment manufacturer’s
Transportation Department.
ORIGINAL INSTRUCTIONS − PRINTED IN USA
© 2016 Miller Electric Mfg. Co. 2016−01
Via Privata Iseo, 6/E
20098 San Giuliano
Milanese, Italy
Phone: 39 (0) 2982901
Fax: 39 (0) 298290-203
email: miller@itw−welding.it
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising