Miller S-32P SUPER ULTRA-LITE Owner`s manual

Add to my manuals
36 Pages

advertisement

Miller S-32P SUPER ULTRA-LITE Owner`s manual | Manualzz
OM-184 517F
April 2001
Processes
MIG (GMAW) Welding
Flux Cored (FCAW) Welding
Description
Wire Feeder
Super S-32P Ultra-Lite
Visit our website at
www.MillerWelds.com
From Miller to You
Thank you and congratulations on choosing Miller. Now
you can get the job done and get it done right. We know
you don’t have time to do it any other way.
That’s why when Niels Miller first started building arc
welders in 1929, he made sure his products offered
long-lasting value and superior quality. Like you, his
customers couldn’t afford anything less. Miller products
had to be more than the best they could be. They had to
be the best you could buy.
Today, the people that build and sell Miller products continue the
tradition. They’re just as committed to providing equipment and service
that meets the high standards of quality and value established in 1929.
This Owner’s Manual is designed to help you get the most out of your
Miller products. Please take time to read the Safety precautions. They will
help you protect yourself against potential hazards on the worksite. We’ve
made installation and operation quick and easy.
With Miller you can count on years of reliable
service with proper maintenance. And if for
some reason the unit needs repair, there’s a
Troubleshooting section that will help you
Miller is the first welding figure out what the problem is. The parts list
equipment manufacturer in will then help you to decide which exact part
the U.S.A. to be registered to
the ISO 9001 Quality System you may need to fix the problem. Warranty and
Standard.
service information for your particular model
are also provided.
Miller Electric manufactures a full line
of welders and welding related equipment.
For information on other quality Miller
products, contact your local Miller distributor
to receive the latest full line catalog or
individual catalog sheets. To locate your nearest
distributor or service agency call 1-800-4-A-Miller,
or visit us at www.MillerWelds.com on the web.
Working as hard as you do
– every power source from
Miller is backed by the most
hassle-free warranty in the
business.
Miller offers a Technical
Manual which provides
more detailed service and
parts information for your
unit. To obtain a Technical
Manual, contact your local
distributor. Your distributor
can also supply you with
Welding Process Manuals
such as SMAW, GTAW,
GMAW, and GMAW-P.
TABLE OF CONTENTS
WARNING
This product, when used
for welding or cutting,
produces fumes or
gases which contain
chemicals known to the
State of California to
cause birth defects and,
in some cases, cancer.
(California Health &
Safety Code Section
25249.5 et seq.)
OM-184 517
SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . .
1-4. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 1 – CONSIGNES DE SECURITE – LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . .
1-1. Signification des symboles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Dangers relatifs au soudage à l’arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement
et la maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. Information sur les champs électromagnétiques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 – DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1. Warning Label Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2. Manufacturer’s Rating Label For CE Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3. Symbols And Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 – INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2. Installing And Aligning Wire Guide And Drive Roll . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-3. Typical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-4. Gun Recommendation Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-5. Connecting Welding Gun And Voltage Sensing Lead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-6. Connecting Shielding Gas (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-7. Connecting Weld Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-8. Installing And Threading Welding Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 4 – OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-1. Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 5 – MAINTENANCE & TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2. Overload Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-3. Calibrating Optional IPM Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-4. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 – ELECTRICAL DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 7 – PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPTIONS AND ACCESSORIES
WARRANTY
1
1
1
3
3
4
5
5
5
7
8
8
9
9
10
10
11
11
12
13
13
13
14
14
15
16
16
17
17
17
18
19
20
22
Declaration of Conformity for
European Community (CE) Products
NOTE
This information is provided for units with CE certification (see rating label on unit).
Miller Electric Mfg. Co.
Manufacturer’s Name:
1635 W. Spencer Street
Appleton, WI 54914 USA
Manufacturer’s Address:
Declares that the product:
Super S-32P Ultra-Lite
conforms to the following Directives and Standards:
Directives
Low Voltage Directive: 73/23/EEC
Electromagnetic Compatibility (EMC) Directive: 89/336/EEC
Machinery Directives: 89/392/EEC, 91/368/EEC, 93/C 133/04, 93/68/EEC
Standards
Arc Welding Equipment Part I: Welding Power Sources: IEC 974-1
(April 1995 – Draft Revision)
Arc Welding Equipment: Wirefeed Systems: IEC 974-4
(May 1995 – Draft Revision)
Degrees of Protection Provided By Enclosures (IP Code): IEC 529:1989
Insulation Coordination For Equipment With Low-Voltage Systems:
Part I: Principles, Requirements and Tests: IEC 664-1: 1992
Electromagnetic Compatibility, (EMC): EN 50199
European Contact:
Telephone:
Fax:
dec_con1 1/96
Mr. Danilo Fedolfi, Managing Director
MILLER Europe S.r.l.
Via Privata Iseo
20098 San Giuliano
Milanese, Italy
39(02)98290-1
39(02)98281-552
SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING
som _nd_4/98
1-1. Symbol Usage
Means Warning! Watch Out! There are possible hazards
with this procedure! The possible hazards are shown in
the adjoining symbols.
Y Marks a special safety message.
. Means “Note”; not safety related.
This group of symbols means Warning! Watch Out! possible
ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.
Consult symbols and related instructions below for necessary actions
to avoid the hazards.
1-2. Arc Welding Hazards
Y The symbols shown below are used throughout this manual to
call attention to and identify possible hazards. When you see
the symbol, watch out, and follow the related instructions to
avoid the hazard. The safety information given below is only
a summary of the more complete safety information found in
the Safety Standards listed in Section 1-4. Read and follow all
Safety Standards.
D If earth grounding of the workpiece is required, ground it directly
with a separate cable.
Y Only qualified persons should install, operate, maintain, and
repair this unit.
D Wear a safety harness if working above floor level.
D Keep all panels and covers securely in place.
Y During operation, keep everybody, especially children, away.
D Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shocks
or severe burns. The electrode and work circuit is
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also
live when power is on. In semiautomatic or automatic wire welding, the
wire, wire reel, drive roll housing, and all metal parts touching the
welding wire are electrically live. Incorrectly installed or improperly
grounded equipment is a hazard.
D Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
D Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
D Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
D Do not connect more than one electrode or work cable to any
single weld output terminal.
SIGNIFICANT DC VOLTAGE exists after removal of
input power on inverters.
D Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section
before touching any parts.
D Do not touch live electrical parts.
D Wear dry, hole-free insulating gloves and body protection.
D Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.
D Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
D Use AC output ONLY if required for the welding process.
D If AC output is required, use remote output control if present on
unit.
D Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
D Properly install and ground this equipment according to its
Owner’s Manual and national, state, and local codes.
D Keep your head out of the fumes. Do not breathe the fumes.
D Always verify the supply ground – check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
grounded receptacle outlet.
D When making input connections, attach proper grounding conductor first – double-check connections.
D Frequently inspect input power cord for damage or bare wiring –
replace cord immediately if damaged – bare wiring can kill.
D Turn off all equipment when not in use.
D Do not use worn, damaged, undersized, or poorly spliced cables.
D Do not weld in locations near degreasing, cleaning, or spraying operations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.
D Do not drape cables over your body.
FUMES AND GASES can be hazardous.
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health.
D If inside, ventilate the area and/or use exhaust at the arc to remove
welding fumes and gases.
D If ventilation is poor, use an approved air-supplied respirator.
D Read the Material Safety Data Sheets (MSDSs) and the
manufacturer’s instructions for metals, consumables, coatings,
cleaners, and degreasers.
D Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watchperson nearby. Welding fumes and gases can displace air and
lower the oxygen level causing injury or death. Be sure the breathing air is safe.
D Do not weld on coated metals, such as galvanized, lead, or
cadmium plated steel, unless the coating is removed from the weld
area, the area is well ventilated, and if necessary, while wearing an
air-supplied respirator. The coatings and any metals containing
these elements can give off toxic fumes if welded.
OM-184 517 Page 1
ARC RAYS can burn eyes and skin.
Arc rays from the welding process produce intense
visible and invisible (ultraviolet and infrared) rays
that can burn eyes and skin. Sparks fly off from the
weld.
D Wear a welding helmet fitted with a proper shade of filter to protect
your face and eyes when welding or watching (see ANSI Z49.1
and Z87.1 listed in Safety Standards).
D Wear approved safety glasses with side shields under your
helmet.
D Use protective screens or barriers to protect others from flash and
glare; warn others not to watch the arc.
D Wear protective clothing made from durable, flame-resistant material (leather and wool) and foot protection.
BUILDUP OF GAS can injure or kill.
D Shut off shielding gas supply when not in use.
D Always ventilate confined spaces or use
approved air-supplied respirator.
HOT PARTS can cause severe burns.
D Do not touch hot parts bare handed.
D Allow cooling period before working on gun or
torch.
MAGNETIC FIELDS can affect pacemakers.
WELDING can cause fire or explosion.
Welding on closed containers, such as tanks,
drums, or pipes, can cause them to blow up. Sparks
can fly off from the welding arc. The flying sparks, hot
workpiece, and hot equipment can cause fires and
burns. Accidental contact of electrode to metal objects can cause
sparks, explosion, overheating, or fire. Check and be sure the area is
safe before doing any welding.
D Protect yourself and others from flying sparks and hot metal.
D Do not weld where flying sparks can strike flammable material.
D Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
D Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
D Watch for fire, and keep a fire extinguisher nearby.
D Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
D Do not weld on closed containers such as tanks, drums, or pipes,
unless they are properly prepared according to AWS F4.1 (see
Safety Standards).
D Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly
unknown paths and causing electric shock and fire hazards.
D Do not use welder to thaw frozen pipes.
D Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
D Wear oil-free protective garments such as leather gloves, heavy
shirt, cuffless trousers, high shoes, and a cap.
D Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.
FLYING METAL can injure eyes.
D Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool,
they can throw off slag.
D Wear approved safety glasses with side
shields even under your welding helmet.
OM-184 517 Page 2
D Pacemaker wearers keep away.
D Wearers should consult their doctor before
going near arc welding, gouging, or spot
welding operations.
NOISE can damage hearing.
Noise from some processes or equipment can
damage hearing.
D Wear approved ear protection if noise level is
high.
CYLINDERS can explode if damaged.
Shielding gas cylinders contain gas under high
pressure. If damaged, a cylinder can explode. Since
gas cylinders are normally part of the welding
process, be sure to treat them carefully.
D Protect compressed gas cylinders from excessive heat, mechanical shocks, slag, open flames, sparks, and arcs.
D Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
D Keep cylinders away from any welding or other electrical circuits.
D Never drape a welding torch over a gas cylinder.
D Never allow a welding electrode to touch any cylinder.
D Never weld on a pressurized cylinder – explosion will result.
D Use only correct shielding gas cylinders, regulators, hoses, and fittings designed for the specific application; maintain them and
associated parts in good condition.
D Turn face away from valve outlet when opening cylinder valve.
D Keep protective cap in place over valve except when cylinder is in
use or connected for use.
D Read and follow instructions on compressed gas cylinders,
associated equipment, and CGA publication P-1 listed in Safety
Standards.
1-3. Additional Symbols For Installation, Operation, And Maintenance
FIRE OR EXPLOSION hazard.
MOVING PARTS can cause injury.
D Do not install or place unit on, over, or near
combustible surfaces.
D Do not install unit near flammables.
D Do not overload building wiring – be sure power supply system is
properly sized, rated, and protected to handle this unit.
D Keep away from moving parts such as fans.
D Keep all doors, panels, covers, and guards
closed and securely in place.
FALLING UNIT can cause injury.
H.F. RADIATION can cause interference.
D Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
D Use equipment of adequate capacity to lift and
support unit.
D If using lift forks to move unit, be sure forks are
long enough to extend beyond opposite side of
unit.
D
OVERUSE can cause OVERHEATING
D
D Allow cooling period; follow rated duty cycle.
D Reduce current or reduce duty cycle before
starting to weld again.
D Do not block or filter airflow to unit.
D
D
D High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communications equipment.
D Have only qualified persons familiar with
electronic equipment perform this installation.
The user is responsible for having a qualified electrician promptly correct any interference problem resulting from the installation.
If notified by the FCC about interference, stop using the
equipment at once.
Have the installation regularly checked and maintained.
Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.
STATIC (ESD) can damage PC boards.
D Put on grounded wrist strap BEFORE handling
boards or parts.
D Use proper static-proof bags and boxes to
store, move, or ship PC boards.
ARC WELDING can cause interference.
MOVING PARTS can cause injury.
D Keep away from moving parts.
D Keep away from pinch points such as drive
rolls.
D
D
WELDING WIRE can cause injury.
D Do not press gun trigger until instructed to do
so.
D Do not point gun toward any part of the body,
other people, or any metal when threading
welding wire.
D
D
D Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.
D Be sure all equipment in the welding area is
electromagnetically compatible.
To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
Locate welding operation 100 meters from any sensitive electronic equipment.
Be sure this welding machine is installed and grounded
according to this manual.
If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables,
using line filters, or shielding the work area.
1-4. Principal Safety Standards
Safety in Welding and Cutting, ANSI Standard Z49.1, from American
Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126
Safety and Health Standards, OSHA 29 CFR 1910, from Superintendent of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Recommended Safe Practices for the Preparation for Welding and Cutting of Containers That Have Held Hazardous Substances, American
Welding Society Standard AWS F4.1, from American Welding Society,
550 N.W. LeJeune Rd, Miami, FL 33126
National Electrical Code, NFPA Standard 70, from National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
Code for Safety in Welding and Cutting, CSA Standard W117.2, from
Canadian Standards Association, Standards Sales, 178 Rexdale
Boulevard, Rexdale, Ontario, Canada M9W 1R3.
Safe Practices For Occupation And Educational Eye And Face
Protection, ANSI Standard Z87.1, from American National Standards
Institute, 1430 Broadway, New York, NY 10018.
Cutting And Welding Processes, NFPA Standard 51B, from National
Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
OM-184 517 Page 3
1-5. EMF Information
Considerations About Welding And The Effects Of Low Frequency
Electric And Magnetic Fields
Welding current, as it flows through welding cables, will cause electromagnetic fields. There has been and still is some concern about such
fields. However, after examining more than 500 studies spanning 17
years of research, a special blue ribbon committee of the National
Research Council concluded that: “The body of evidence, in the
committee’s judgment, has not demonstrated that exposure to powerfrequency electric and magnetic fields is a human-health hazard.”
However, studies are still going forth and evidence continues to be
examined. Until the final conclusions of the research are reached, you
may wish to minimize your exposure to electromagnetic fields when
welding or cutting.
To reduce magnetic fields in the workplace, use the following
procedures:
OM-184 517 Page 4
1. Keep cables close together by twisting or taping them.
2. Arrange cables to one side and away from the operator.
3. Do not coil or drape cables around your body.
4. Keep welding power source and cables as far away from operator as practical.
5. Connect work clamp to workpiece as close to the weld as possible.
About Pacemakers:
Pacemaker wearers consult your doctor first. If cleared by your doctor,
then following the above procedures is recommended.
SECTION 1 – CONSIGNES DE SECURITE – LIRE AVANT
UTILISATION
som _nd_fre 4/98
1-1. Signification des symboles
Signifie Mise en garde ! Soyez vigilant ! Cette procédure
présente des risques de danger ! Ceux-ci sont identifiés
par des symboles adjacents aux directives.
Y Identifie un message de sécurité particulier.
. Signifie NOTA ; n’est pas relatif à la sécurité.
Ce groupe de symboles signifie Mise en garde ! Soyez vigilant ! Il y a des
risques de danger reliés aux CHOCS ÉLECTRIQUES, aux PIÈCES EN
MOUVEMENT et aux PIÈCES CHAUDES. Reportez-vous aux symboles
et aux directives ci-dessous afin de connaître les mesures à prendre pour
éviter tout danger.
1-2. Dangers relatifs au soudage à l’arc
Y Les symboles présentés ci-après sont utilisés tout au long du
présent manuel pour attirer votre attention et identifier les risques
de danger. Lorsque vous voyez un symbole, soyez vigilant et
suivez les directives mentionnées afin d’éviter tout danger. Les
consignes de sécurité présentées ci-après ne font que résumer
l’information contenue dans les normes de sécurité énumérées
à la section 1-4. Veuillez lire et respecter toutes ces normes de
sécurité.
Y L’installation, l’utilisation, l’entretien et les réparations ne doivent être confiés qu’à des personnes qualifiées.
Y Au cours de l’utilisation, tenir toute personne à l’écart et plus particulièrement les enfants.
D N’utiliser qu’un matériel en bon état. Réparer ou remplacer sur-lechamp les pièces endommagées. Entretenir l’appareil conformément
à ce manuel.
D Porter un harnais de sécurité quand on travaille en hauteur.
D Maintenir solidement en place tous les panneaux et capots.
D Fixer le câble de retour de façon à obtenir un bon contact métal-métal
avec la pièce à souder ou la table de travail, le plus près possible de la
soudure.
D
Isoler la pince de masse quand pas mis à la pièce pour éviter le contact
avec tout objet métallique.
UN CHOC ÉLECTRIQUE peut tuer.
Un simple contact avec des pièces électriques peut
provoquer une électrocution ou des blessures graves.
L’électrode et le circuit de soudage sont sous tension
dès que l’appareil est sur ON. Le circuit d’entrée et les
circuits internes de l’appareil sont également sous
tension à ce moment-là. En soudage semi-automatique ou automatique,
le fil, le dévidoir, le logement des galets d’entraînement et les pièces
métalliques en contact avec le fil de soudage sont sous tension. Des
matériels mal installés ou mal mis à la terre présentent un danger.
Il y a DU COURANT CONTINU IMPORTANT dans les
convertisseurs après la suppression de l’alimentation électrique.
D Arrêter les convertisseurs, débrancher le courant électrique, et décharger les condensateurs d’alimentation selon les instructions
indiquées dans la partie entretien avant de toucher les pièces.
D Ne jamais toucher les pièces électriques sous tension.
D Porter des gants et des vêtements de protection secs ne comportant
pas de trous.
D S’isoler de la pièce et de la terre au moyen de tapis ou d’autres
moyens isolants suffisamment grands pour empêcher le contact physique éventuel avec la pièce ou la terre.
D
D
D
Ne pas se servir de source électrique àcourant électrique dans les zones
humides, dans les endroits confinés ou là où on risque de tomber.
Se servir d’une source électrique àcourant électrique UNIQUEMENT si le
procédé de soudage le demande.
Si l’utilisation d’une source électrique àcourant électrique s’avère nécessaire, se servir de la fonction de télécommande si l’appareil en est équipé.
D Couper l’alimentation ou arrêter le moteur avant de procéder à l’installation, à la réparation ou à l’entretien de l’appareil. Déverrouiller
l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de
sécurité).
D Installer et mettre à la terre correctement cet appareil conformément à
son manuel d’utilisation et aux codes nationaux, provinciaux et
municipaux.
D Toujours vérifier la terre du cordon d’alimentation – Vérifier et s’assurer que le fil de terre du cordon d’alimentation est bien raccordé à la
borne de terre du sectionneur ou que la fiche du cordon est raccordée
à une prise correctement mise à la terre.
D En effectuant les raccordements d’entrée fixer d’abord le conducteur
de mise à la terre approprié et contre-vérifier les connexions.
D Vérifier fréquemment le cordon d’alimentation pour voir s’il n’est pas
endommagé ou dénudé – remplacer le cordon immédiatement s’il est
endommagé – un câble dénudé peut provoquer une électrocution.
D Mettre l’appareil hors tension quand on ne l’utilise pas.
D Ne pas utiliser des câbles usés, endommagés, de grosseur insuffisante ou mal épissés.
D Ne pas enrouler les câbles autour du corps.
D Si la pièce soudée doit être mise à la terre, le faire directement avec un
câble distinct.
D Ne pas toucher l’électrode quand on est en contact avec la pièce, la
terre ou une électrode provenant d’une autre machine.
LES FUMÉES ET LES GAZ peuvent
être dangereux.
Le soudage génère des fumées et des gaz. Leur
inhalation peut être dangereux pour votre santé.
D
D
D
D
D
D
D Eloigner votre tête des fumées. Ne pas respirer
les fumées.
A l’intérieur, ventiler la zone et/ou utiliser un échappement au niveau
de l’arc pour l’évacuation des fumées et des gaz de soudage.
Si la ventilation est insuffisante, utiliser un respirateur à alimentation d’air homologué.
Lire les spécifications de sécurité des matériaux (MSDSs) et les
instructions du fabricant concernant les métaux, les consommables, les revêtements, les nettoyants et les dégraisseurs.
Travailler dans un espace fermé seulement s’il est bien ventilé ou en
portant un respirateur à alimentation d’air. Demander toujours à un
surveillant dûment formé de se tenir à proximité. Des fumées et des
gaz de soudage peuvent déplacer l’air et abaisser le niveau d’oxygène provoquant des blessures ou des accidents mortels. S’assurer que l’air de respiration ne présente aucun danger.
Ne pas souder dans des endroits situés à proximité d’opérations de
dégraissage, de nettoyage ou de pulvérisation. La chaleur et les
rayons de l’arc peuvent réagir en présence de vapeurs et former des
gaz hautement toxiques et irritants.
Ne pas souder des métaux munis d’un revêtement, tels que l’acier
galvanisé, plaqué en plomb ou au cadmium à moins que le revêtement n’ait été enlevé dans la zone de soudure, que l’endroit soit bien
ventilé, et si nécessaire, en portant un respirateur à alimentation
d’air. Les revêtements et tous les métaux renfermant ces éléments
peuvent dégager des fumées toxiques en cas de soudage.
OM-184 517 Page 5
LES RAYONS DE L’ARC peuvent provoquer des brûlures dans les yeux et
sur la peau.
Le rayonnement de l’arc du procédé de soudage
génère des rayons visibles et invisibles intenses
(ultraviolets et infrarouges) susceptibles de provoquer
des brûlures dans les yeux et sur la peau. Des étincelles sont projetées
pendant le soudage.
D Porter un casque de soudage muni d’un écran de filtre approprié pour
protéger votre visage et vos yeux pendant le soudage ou pour regarder (voir ANSI Z49.1 et Z87.1 énuméré dans les normes de sécurité).
D Porter des protections approuvés pour les oreilles si le niveau sondre est
trop élevé.
D Utiliser des écrans ou des barrières pour protéger des tiers de l’éclair
et de l’éblouissement; demander aux autres personnes de ne pas regarder l’arc.
D Porter des vêtements de protection constitué dans une matière durable, résistant au feu (cuir ou laine) et une protection des pieds.
LE SOUDAGE peut provoquer un
incendie ou une explosion.
Le soudage effectué sur des conteneurs fermés tels
que des réservoirs, tambours ou des conduites peut
provoquer leur éclatement. Des étincelles peuvent être
projetées de l’arc de soudure. La projection d’étincelles, des pièces chaudes et des équipements chauds peut provoquer des
incendies et des brûlures. Le contact accidentel de l’électrode avec des
objets métalliques peut provoquer des étincelles, une explosion, un
surchauffement ou un incendie. Avant de commencer le soudage, vérifier
et s’assurer que l’endroit ne présente pas de danger.
D Se protéger et d’autres personnes de la projection d’étincelles et de
métal chaud.
D Ne pas souder dans un endroit là où des étincelles peuvent tomber sur
des substances inflammables.
D Déplacer toutes les substances inflammables à une distance de 10,7
m de l’arc de soudage. En cas d’impossibilité les recouvrir soigneusement avec des protections homologués.
D Des étincelles et des matériaux chauds du soudage peuvent facilement passer dans d’autres zones en traversant de petites fissures et
des ouvertures.
D Surveiller tout déclenchement d’incendie et tenir un extincteur à proximité.
D Le soudage effectué sur un plafond, plancher, paroi ou séparation
peut déclencher un incendie de l’autre côté.
D Ne pas effectuer le soudage sur des conteneurs fermés tels que des
réservoirs, tambours, ou conduites, à moins qu’ils n’aient été préparés correctement conformément à AWS F4.1 (voir les normes de
sécurité).
D Brancher le câble sur la pièce le plus près possible de la zone de soudage pour éviter le transport du courant sur une longue distance par
des chemins inconnus éventuels en provoquant des risques d’électrocution et d’incendie.
D Ne pas utiliser le poste de soudage pour dégeler des conduites gelées.
D En cas de non utilisation, enlever la baguette d’électrode du porteélectrode ou couper le fil à la pointe de contact.
D Porter des vêtements de protection dépourvus d’huile tels que des
gants en cuir, une chemise en matériau lourd, des pantalons sans revers, des chaussures hautes et un couvre chef.
D Avant de souder, retirer toute substance combustible de vos poches
telles qu’un allumeur au butane ou des allumettes.
DES PARTICULES VOLANTES
peuvent blesser les yeux.
D Le soudage, l’écaillement, le passage de la pièce
à la brosse en fil de fer, et le meulage génèrent
des étincelles et des particules métalliques volantes. Pendant la période de refroidissement des soudures, elles risquent de projeter du laitier.
D
Porter des lunettes de sécurité avec écrans latéraux ou un écran facial.
OM-184 517 Page 6
LES ACCUMULATIONS DE GAZ risquent de provoquer des blessures ou
même la mort.
D
D
Fermer l’alimentation du gaz protecteur en cas de
non utilisation.
Veiller toujours à bien aérer les espaces confinés ou se servir d’un respirateur d’adduction d’air homologué.
DES PIÈCES CHAUDES peuvent provoquer des brûlures graves.
D Ne pas toucher des parties chaudes à mains nues
D Prévoir une période de refroidissement avant
d’utiliser le pistolet ou la torche.
LES CHAMPS MAGNÉTIQUES peuvent
affecter les stimulateurs cardiaques.
D
D
Porteurs de stimulateur cardiaque, restez à distance.
Les porteurs d’un stimulateur cardiaque doivent
d’abord consulter leur médecin avant de s’approcher
des opérations de soudage à l’arc, de gougeage ou
de soudage par points.
LE BRUIT peut affecter l’ouïe.
Le bruit des processus et des équipements peut affecter
l’ouïe.
D
Porter des protections approuvés pour les oreilles si
le niveau sondre est trop élevé.
Si des BOUTEILLES sont endommagées, elles pourront exploser.
Des bouteilles de gaz protecteur contiennent du gaz
sous haute pression. Si une bouteille est endommagée, elle peut exploser. Du fait que les bouteilles de gaz
font normalement partie du procédé de soudage, les
manipuler avec précaution.
D Protéger les bouteilles de gaz comprimé d’une chaleur excessive,
des chocs mécaniques, du laitier, des flammes ouvertes, des étincelles et des arcs.
D Placer les bouteilles debout en les fixant dans un support stationnaire ou dans un porte-bouteilles pour les empêcher de tomber ou de
se renverser.
D Tenir les bouteilles éloignées des circuits de soudage ou autres circuits électriques.
D Ne jamais placer une torche de soudage sur une bouteille à gaz.
D Une électrode de soudage ne doit jamais entrer en contact avec une
bouteille.
D Ne jamais souder une bouteille pressurisée – risque d’explosion.
D Utiliser seulement des bouteilles de gaz protecteur, régulateurs,
tuyaux et raccords convenables pour cette application spécifique;
les maintenir ainsi que les éléments associés en bon état.
D Ne pas tenir la tête en face de la sortie en ouvrant la soupape de la
bouteille.
D Maintenir le chapeau de protection sur la soupape, sauf en cas d’utilisation ou de branchement de la bouteille.
D Lire et suivre les instructions concernant les bouteilles de gaz comprimé, les équipements associés et les publications P-1 CGA énumérées dans les normes de sécurité.
1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement
et la maintenance
Risque D’INCENDIE OU
D’EXPLOSION.
DES ORGANES MOBILES peuvent
provoquer des blessures.
D Ne pas placer l’appareil sur, au-dessus ou à proximité de surfaces infllammables.
D Rester à l’écart des organes mobiles comme le
ventilateur.
D Maintenir fermés et fixement en place les portes,
panneaux, recouvrements et dispositifs de
protection.
D Ne pas installer l’appareil à proximité de produits inflammables
D Ne pas surcharger l’installation électrique – s”assurer que l’alimentation est correctement dimensionné et protégé avant de mettre
l’appareil en service.
LE RAYONNEMENT HAUTE FRÉQUENCE (H.F.) risque de provoquer
des interférences.
LA CHUTE DE L’APPAREIL peut
blesser.
D Utiliser l’anneau de levage uniquement pour soulever l’appareil, NON PAS les chariot, les bouteilles de gaz ou tout autre accessoire.
D Utiliser un engin d’une capacité appropriée pour
soulever l’appareil.
D En utilisant des fourches de levage pour déplacer l’unité, s’assurer
que les fourches sont suffisamment longues pour dépasser du côté
opposé de l’appareil.
L’EMPLOI EXCESSIF peut
SURCHAUFFER L’ÉQUIPEMENT.
D
D
D
D
D
D Prévoir une période de refroidissement, respecter le cycle opératoire nominal.
D Réduire le courant ou le cycle opératoire avant de
recommancer le soudage.
LE SOUDAGE À L’ARC risque de
provoquer des interférences.
D Ne pas obstruer les passages d’air du poste.
LES CHARGES ÉLECTROSTATIQUES peuvent endommager les circuits imprimés.
D Établir la connexion avec la barrette de terre
avant de manipuler des cartes ou des pièces.
D Utiliser des pochettes et des boîtes antistatiques
pour stocker, déplacer ou expédier des cartes de
circuits imprimes.
DES ORGANES MOBILES peuvent
provoquer des blessures.
D Ne pas s’approcher des organes mobiles.
D Ne pas s’approcher des points de coincement
tels que des rouleaux de commande.
LES FILS DE SOUDAGE peuvent provoquer des blessures.
D Ne pas appuyer sur la gachette avant d’en avoir
reçu l’instruction.
D Ne pas diriger le pistolet vers soi, d’autres personnes ou toute pièce mécanique en engageant le fil
de soudage.
D Le rayonnement haute frequence peut provoquer
des interférences avec les équipements de radio–navigation et de communication, les services
de sécurité et les ordinateurs.
Demander seulement à des personnes qualifiées familiarisées
avec des équipements électroniques de faire fonctionner l’installation.
L’utilisateur est tenu de faire corriger rapidement par un électricien
qualifié les interférences résultant de l’installation.
Si le FCC signale des interférences, arrêter immédiatement l’appareil.
Effectuer régulièrement le contrôle et l’entretien de l’installation.
Maintenir soigneusement fermés les portes et les panneaux des
sources de haute fréquence, maintenir les éclateurs à une distance
correcte et utiliser une terre et et un blindage pour réduire les interférences éventuelles.
D
D
D
D
D
D L’énergie électromagnétique risque de provoquer
des interférences pour l’équipement électronique
sensible tel que les ordinateurs et l’équipement
commandé par ordinateur tel que les robots.
Veiller à ce que tout l’équipement de la zone de soudage soit compatible électromagnétiquement.
Pour réduire la possibilité d’interférence, maintenir les câbles de
soudage aussi courts que possible, les grouper, et les poser aussi
bas que possible (ex. par terre).
Veiller à souder à une distance de 100 mètres de tout équipement
électronique sensible.
Veiller à ce que ce poste de soudage soit posé et mis à la terre
conformément à ce mode d’emploi.
En cas d’interférences après avoir pris les mesures précédentes, il
incombe à l’utilisateur de prendre des mesures supplémentaires telles que le déplacement du poste, l’utilisation de câbles blindés, l’utilisation de filtres de ligne ou la pose de protecteurs dans la zone de
travail.
LES CHAMPS MAGNÉTIQUES peuvent
affecter les stimulateurs cardiaques.
D Porteurs de stimulateur cardiaque, restez à distance.
D Les porteurs d’un stimulateur cardiaque doivent
d’abord consulter leur médecin avant de s’approcher des opérations de soudage à l’arc, de gougeage ou de soudage par points.
OM-184 517 Page 7
1-4. Principales normes de sécurité
Safety in Welding and Cutting, norme ANSI Z49.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL 33126
Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent
of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Recommended Safe Practice for the Preparation for Welding and Cutting of Containers That Have Held Hazardous Substances, norme AWS
F4.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL
33126
National Electrical Code, NFPA Standard 70, de la National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
de la Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
Règles de sécurité en soudage, coupage et procédés connexes, norme
CSA W117.2, de l’Association canadienne de normalisation, vente de
normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.
Safe Practices For Occupation And Educational Eye And Face Protection, norme ANSI Z87.1, de l’American National Standards Institute,
1430 Broadway, New York, NY 10018.
Cutting and Welding Processes, norme NFPA 51B, de la National Fire
Protection Association, Batterymarch Park, Quincy, MA 02269.
1-5. Information sur les champs électromagnétiques
Données sur le soudage électrique et sur les effets, pour l’organisme,
des champs magnétiques basse fréquence
Afin de réduire les champs électromagnétiques dans l’environnement
de travail, respecter les consignes suivantes :
1
Le courant de soudage, pendant son passage dans les câbles de soudage, causera des champs électromagnétiques. Il y a eu et il y a encore
un certain souci à propos de tels champs. Cependant, après avoir examiné plus de 500 études qui ont été faites pendant une période de
recherche de 17 ans, un comité spécial ruban bleu du National Research Council a conclu: “L’accumulation de preuves, suivant le
jugement du comité, n’a pas démontré que l’exposition aux champs
magnétiques et champs électriques à haute fréquence représente un
risque à la santé humaine”. Toutefois, des études sont toujours en cours
et les preuves continuent à être examinées. En attendant que les conclusions finales de la recherche soient établies, il vous serait
souhaitable de réduire votre exposition aux champs électromagnétiques pendant le soudage ou le coupage.
OM-184 517 Page 8
2
3
4
5
Garder les câbles ensembles en les torsadant ou en les
attachant avec du ruban adhésif.
Mettre tous les câbles du côté opposé de l’opérateur.
Ne pas courber pas et ne pas entourer pas les câbles autour de
votre corps.
Garder le poste de soudage et les câbles le plus loin possible de
vous.
Relier la pince de masse le plus près possible de la zone de
soudure.
Consignes relatives aux stimulateurs cardiaques :
Les personnes qui portent un stimulateur cardiaque doivent avant tout
consulter leur docteur. Si vous êtes déclaré apte par votre docteur, il est
alors recommandé de respecter les consignes ci–dessus.
SECTION 2 – DEFINITIONS
2-1. Warning Label Definitions
Warning! Watch Out! There are
possible hazards as shown by the
symbols.
Drive rolls can injure fingers
Welding wire and drive parts are at
welding voltage during operation –
keep hands and metal objects
clear.
1
1.1
2
2.1
3
3.1
4
4.1
1.2
2.2
2.3
3.2
+
5
1.3
3.3
+
+
6
+
S-178 936
1 Electric shock can kill.
1.1 Wear dry insulating gloves.
Do not touch electrode with
bare hand. Do not wear wet or
damaged gloves.
1.2 Protect yourself from electric
shock by insulating yourself
from work and ground.
1.3 Disconnect input plug or
power before working on
machine.
2 Breathing welding fumes can
be hazardous to your health.
2.1 Keep your head out of the
fumes.
2.2 Use forced ventilation or local
exhaust to remove the fumes.
2.3 Use ventilating fan to remove
fumes.
3 Welding sparks can cause
explosion or fire.
3.1 Keep flammables away from
welding. Don’t weld near
flammables.
3.2 Welding sparks can cause
fires. Have a fire extinguisher
nearby and have a watch
person ready to use it.
3.3 Do not weld on drums or any
closed containers.
4 Arc rays can burn eyes and
injure skin.
4.1 Wear hat and safety glasses.
Use ear protection and button
shirt collar. Use welding
helmet with correct shade of
filter. Wear complete body
protection.
5 Become trained and read the
instructions before working on
the machine or welding.
6 Do not remove or paint over
(cover) the label.
OM-184 517 Page 9
2-2. Manufacturer’s Rating Label For CE Products
For label location
see Section 4-1.
S/N:
Hz
DC
IP 23
U1 100 V
=I1= 7.0 A
U2 100 V
=
I2= 500 A
X 100 %
ST-181 678
2-3. Symbols And Definitions
NOTE
X
Some symbols are found only on CE products.
Input
Duty Cycle
Wire Feed
Percent
Input
Cold Jog (Inch) Towards Workpiece
Purge By Gas
Read Instructions
I1
A
Output
Primary Current
OM-184 517 Page 10
U1
I2
Primary Voltage
Rated Welding
Current
U2
Amperes
Conventional Load
Voltage
V
IP
Volts
Degree Of Protection
Increase
Hz
Hertz
SECTION 3 – INSTALLATION
3-1. Specifications
Type of
Input
Power
Open-Circuit/
Arc Voltage,
15 To 100
Volts DC
Welding
Power
Source
Type
Constant
Voltage (CV)
Or Constant
Current (CC)
DC
Wire Feed
Speed
Range
50 To 700 ipm
(1.3 To 18
mpm)
Depending
On Arc
Voltage
Wire
Diameter
Range
Input
Welding
Circuit
Rating
IP
Rating
Max. Wire
Spool
Capacity
500 Amperes
At 100%
Duty Cycle
.023 To 5/64 in
(0.6 To 2 mm)
330 Amperes
At 60%
Duty Cycle
With Optional
Secondary
Contactor
Overall
Dimensions
Weight
Length: 22-1/2
in (572 mm)
23
30 lb (13.6 kg),
12 in (304 mm)
Width: 8-3/4 in
(222 mm)
24 lb
(10.9 kg)
Height: 15-3/4
in (400 mm)
OM-184 517 Page 11
3-2. Installing And Aligning Wire Guide And Drive Roll
When changing wire size or type,
check drive roll and wire guide size
(see Parts List).
Installing Wire Guide And Drive
Rolls:
1
2
Drive Roll Nut
Drive Roll Carrier
Turn nut one click until lobes of nut
line up with lobes of drive roll carrier.
3
Drive Roll
Slide drive roll onto drive roll carrier.
Turn nut one click.
Repeat procedure for top drive roll.
4
5
Inlet Wire Guide Screw
Inlet Wire Guide
Loosen securing screw. Install inlet
guide so inlet guide screw is
centered in groove in guide, or so tip
is as close to drive rolls as possible
without touching. Tighten screw.
Aligning Wire Guide And Drive
Rolls:
Only top drive roll alignment is adjustable. Turn adjustment screw in
or out until groove in drive roll lines
up with wire guide as shown.
Cleaning Drive Rolls:
Remove drive rolls, and clean
grooves using a wire brush.
5
4
3
Tools Needed:
1
2
3/16 in
3/8 in
Alignment
ST-132 809-B / Ref. ST-132 808-F / Ref. ST-162 079-A / Ref. S-180 967
OM-184 517 Page 12
3-3. Typical Connections
1
CC Or CV Welding Power
Source
If using a CC welding power source
without a weld output contactor, use
optional secondary contactor.
2
3
1
Weld Cable
Work
For GMAW, use optional gas valve.
2
3
3-4. Gun Recommendation Table
Process
Gun
GMAW – Hard or Corded Wires
M25 Or M40
FCAW – Self-Shielding Wires
GA-40GL
3-5. Connecting Welding Gun And Voltage Sensing Lead
1
2
3
Gun Securing Knob
Gun Block
Gun Outlet Wire Guide
Loosen knob, insert gun end into
block. Position outlet wire guide as
close as possible to drive rolls without touching. Tighten knob.
4
5
6
Gun Trigger Plug
Gun Trigger Receptacle
Voltage Sensing Clamp
Connect to workpiece.
7
7
Gun Holder
1
2
4
3
6
5
ST-800 588-A / Ref. S-0621-C
OM-184 517 Page 13
3-6. Connecting Shielding Gas (Optional)
1
2
3
4
4
3
Gas Hose With 5/8-18
Right-hand Thread Fittings
(Customer Supplied)
Shielding Gas Cylinder
Valve
Flowmeter
Close valve on cylinder when finished welding.
Rear View
2
1
Tools Needed:
5/8 in
ST-801 155-A
3-7. Connecting Weld Cable
1
Standard Model
Weld Cable
Follow wire manufacturer’s recommendations for weld cable polarity.
2
3
Male Connector
Female Connector
Close door, push female connector
over male connector, and turn 1/4
turn clockwise.
1
2
3
With Optional
Internal Contactor
1
2
3
Ref. ST-132 808-F / Ref. ST-157 658-D
OM-184 517 Page 14
3-8. Installing And Threading Welding Wire
1
2
Retaining Ring
Hub Tension Adjustment Nut
Installing Wire And Adjusting
Hub Tension:
Remove retaining ring, and install
spool so hub pin fits spool hole. Reinstall retaining ring.
Adjust tension nut so only a slight
force is needed to turn spool.
Threading Welding Wire:
3
Pressure Assembly
Adjustment Knob
Lay gun cable out straight.
2
1
3
A
B
C
D
A
Open pressure assembly,
hold wire tightly, and cut off
end. Push wire through
guides into gun.
B
Close and tighten pressure
assembly. Press gun trigger until wire comes out
gun.
C
Feed wire against wooden
surface, and tighten knob
so wire does not slip.
D
Cut off wire, and close
door.
Tighten
WOOD
Tools Needed:
9/16 in
ST-800 586-B / Ref. ST-159 048-A / S-0627-A
OM-184 517 Page 15
SECTION 4 – OPERATION
4-1. Controls
1
2
Wire Speed Meter (Optional)
Voltage Meter (Optional)
Use meter to set and display rate of
wire speed in inches per minute
(ipm).
1
2
3
5
3
4
5
Power Control Switch
Wire Speed Range Switch
Wire Speed Control
Use switch to select high or low wire
speed range. High range is 100 to
700 ipm. Low range is 50 to 350
ipm.
Use control to adjust wire speed
within range selected by switch.
6
4
Purge Switch (Optional)
Press switch to momentarily energize gas solenoid and purge air
from gun, and to adjust shielding
gas regulator.
7
CC/CV Switch
Use switch to match wire feeder
with welding power source output.
8
7
8
Rating Label Location
6
Ref. ST-139 026-B / Ref. ST-132 808-F
OM-184 517 Page 16
SECTION 5 – MAINTENANCE & TROUBLESHOOTING
5-1. Routine Maintenance
. Maintain more often
Y Disconnect power
before maintaining.
during severe conditions.
3 Months
Clean And
Tighten
Weld
Terminals
Replace
Damaged Or
Unreadable
Labels
Replace Damaged
Gas Hose
Repair Or Replace
Cracked Cables
And Cords
6 Months
Clean
Drive
Rolls
Blow Out Or
Vacuum Inside
5-2. Overload Protection
Y Turn Off wire feeder and
welding power source. Stop
engine
on
welding
generator.
1
2
Overload
Protection
Circuit Breaker CB1
Fuse F1
CB1 and F1 protect wire feeder
from overload. Correct problem and
reset CB1 or replace F1.
CB1
PRESS TO RESET
Close and latch door.
1
2
Ref. ST-800 586-B / Ref. S-801 128-A
OM-184 517 Page 17
5-3. Calibrating Optional IPM Meter
Meter is factory calibrated, but may
need recalibration after motor
brushes are fully seated. To recalibrate, proceed as follows:
1
1
CV/CC Switch
Set switch to CV.
2
2
3
3
4
4
Meter Board PC4
Resistor R53 Adjustment
Screw (High Range)
Resistor R54 Adjustment
Screw (Low Range)
Calibrate Low range wire speed
first.
5
6
Nonconductive
Wire Speed Range Switch
Wire Speed Control
A
Set range switch to Low,
and control to about 50%.
Turn wire feeder and welding power source On.
B
Press trigger and feed wire
for 15 seconds. Measure
wire length, and multiply x
4 to get actual ipm. For example: If 49 inches feeds in
15 sec, 49 x 4 = 196 actual
ipm.
C
Press trigger again: Meter
reading should match actual ipm value, 196 in example. If not, press trigger
and carefully adjust R54
until meter reads 196.
A
6
5
After Low range is calibrated, set
range switch to High. Leave control
at same setting (about 380 ipm).
Repeat procedure to calibrate High
range wire speed: About 95 inches
should feed in 15 sec, 95 x 4 = 380
ipm. If needed, adjust R53 so meter
reading matches actual ipm.
Turn off power. Close and latch
door.
C
B
0
15
Ref. ST-800 586-B / Ref. ST-176 180
OM-184 517 Page 18
5-4. Troubleshooting
Trouble
Remedy
Wire does not feed; open-circuit voltage Check circuit breaker CB1 and fuse F1. Reset CB1 or replace F1 if necessary (see Section 5-2).
available.
Check sensing lead connection.
Check gun trigger plug connection.
Check gun trigger. See gun Owner’s Manual.
Have Factory Authorized Service Agent check drive motor and control board PC1.
Wire feeds erratically.
Readjust hub tension (see Section 3-8).
Readjust drive roll pressure (see Section 3-8).
Use correct size drive roll (see Parts Listing)
Clean or replace dirty or worn drive roll (see Section 3-2).
Remove weld spatter around nozzle opening.
Replace contact tip or liner. See gun Owner’s Manual.
Have Factory Authorized Service Agent check drive motor and control board PC1.
Wire feeds as soon as power is applied. Check gun trigger. See gun Owner’s Manual.
Wire stubbing on low end using a con- Make sure CC/CV switch is in CC position (see Section 4-1).
stant current power source.
Increase output setting of power source.
Inaccurate optional IPM meter.
Calibrate meter (see Section 5-3).
Optional meters not working.
Have Factory Authorized Service Agent check meter board PC4 and control board PC1.
Gas does not flow; wire feeds.
Check optional gas valve and flowmeter.
Have Factory Authorized Service Agent check control board PC1.
Gas does not stop flowing; wire feeds.
Adjust optional flowmeter.
Have Factory Authorized Service Agent check control board PC1.
OM-184 517 Page 19
SECTION 6 – ELECTRICAL DIAGRAM
SC-176 218
Figure 6-1. Circuit Diagram For Wire Feeder
OM-184 517 Page 20
Notes
OM-184 517 Page 21
OM-184 517 Page 22
25
1
2
28
5
27
Figure 7-1. Complete Assembly
**Includes Item 36
10
31
102
103
13
14
15
86
87
89
90
101
12
88
95
85
94
93
92
91
30
84
100
83
3
96
98
99
20
82
19
81
97
22
21
33**
37
80
79
78
32
77
23*
32
35
34
40
39
38
41
25
70
71
76
26
75
24
36
74
44
43
73
69
45
72
46
68
67
47
66
61
49
52
65
62
51
50
60
48
64
63
59
53
57
55
56
54
58
not available unless listed.
*Includes Items 27 Thru 29
29
4
3
9
16
17
18
42
. Hardware is common and
6
7
8
See Table 7-1 For
Drive Roll & Wire Guide Kits
SECTION 7 – PARTS LIST
802 381
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 7-1. Complete Assembly
. . 1 . . . . . . . . . . . . . . 058 427
. . 2 . . . . . . . . . . . . . . 601 965
. . 3 . . . . . . . . . . . . . . 602 243
. . 4 . . . . . . . . . . . . . . 010 233
. . 5 . . . . . . . . . . . . . . 057 971
. . 6 . . . . . . . . . . . . . . 010 191
. . 7 . . . . . . . . . . . . . . 058 628
. . 8 . . . . . . . . . . . . . . 058 428
. . 9 . . . . . . . . . . . . . . 058 424
. . 10 . . . . . . . . . . . . . 181 513
. . 12 . . . . . . . . . . . . . 602 238
. . 13 . . . . . . . . . . . . . 010 493
. . 14 . . . . S3 . . . . . 094 026
. . 15 . . . . CB1 . . . . 161 078
. . 16 . . . . . . . . . . . . . 046 432
. . 17 . . . . F1 . . . . **012 653
. . 18 . . . . . . . . . . . . . 181 514
. . 19 . . . . . . . . . . . . . 181 519
. . . . . . . . . . . . . . . . . . . 081 895
. . . . . . . . . . . . . . . . . . . 174 829
. . . . . . . . . . . . . . . . . . . 168 590
. . . . . . . . . . . . . . . . . . . 099 037
. . 20 . . . . . . . . . . . . . 603 107
. . 21 . . . . . . . . . . . . . 128 673
. . 22 . . . . . . . . . . . . . 030 170
. . 23 . . . . . . . . . . . . ♦183 710
. . 24 . . . . . . . . . . . . . 010 467
. . 25 . . . . . . . . . . . . . 600 322
. . 26 . . . . . . . . . . . . . 191 981
. . . . . . . . . . . . . . . . . . . 122 968
. . 27 . . . . . . . . . . . . . 195 638
. . 28 . . . . W1 . . . . 192 809
. . 29 . . . . . . . . . . . . . 166 483
. . . . . . . . PLG60 . . . 131 056
. . . . . . . . . . . . . . . . . . . 121 481
. . . . . . . . . . . . . . . . . . . 126 313
. . . . . . . . . . . . . . . . . . . 191 961
. . 30 . . . . . . . . . . . . . . 115 443
. . 31 . . . . PC1 . . . . 201 716
. . . . . . . . PLG50 . . . 166 656
. . . . . . . . PLG51 . . . 166 657
. . . . . . . PLG52,53 . 135 557
. . . . . . . . PLG54 . . . 135 558
. . . . . . . . PLG55 . . . 166 658
. . . . . . . . PLG56 . . . 153 501
. . . . . . . . PLG42 . . . 166 659
. . . . . . . . PLG60 . . . 131 056
. . . . . . . . PLG61 . . . 131 060
. . . . . . . . PLG62 . . . 131 055
. . . . . . . . PLG64 . . . 131 059
. . . . . . . . . RC60 . . . 131 058
. . . . . . . . . . . . . . . . . . . 010 143
. . 32 . . . . . . . . . . . . . 134 834
. . 33 . . . . . . . . . . . . ♦161 809
. . 34 . . . . . . . . . . . . . 126 310
. . RING, retaining spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . SCREW, cap stl hexhd .375-16 x 1.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . WASHER, flat stl std .438 ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . SPRING, cprsn .970 OD x .120 wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . WASHER, flat stl keyed 1.500dia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . WASHER, fbr .656 ID x 1.500 OD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . WASHER, brake stl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . HUB, spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . WASHER, fibre (brake) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . COVER, PC board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . WASHER, flat .203 ID x .50 OD x .048 T stl pld ANSI #10 . . . . . . . . . . . .
. . BUSHING, snap-in nyl .625 ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . SWITCH, tgl DPDT 5A 125VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CIRCUIT BREAKER, man reset 1P 7A 250VAC . . . . . . . . . . . . . . . . . . . . .
. . HOLDER, fuse mintr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . FUSE, mintr gl .5A 250V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . SUPPORT, case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CHASSIS, control box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . NUT, rbr 10-32 .75dia x .81 lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . HOSE, nprn slit bk .156 ID x .343 OD x 4.500 lg . . . . . . . . . . . . . . . . . . . . .
. . BUSHING, insulating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . EDGE TRIM, style 62-1/16 (order by ft) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . HOSE, nprn slit bk .156 ID x .343 OD (order by ft) . . . . . . . . . . . . . . . . . . .
. . WASHER, shldr nyl .625 OD x .203 ID x .312dia shldr . . . . . . . . . . . . . . . .
. . BUSHING, snap-in nyl .750 ID x 1.000mtg hole . . . . . . . . . . . . . . . . . . . . .
. . CONTACTOR KIT, Lenco/Tweco (consisting of) . . . . . . . . . . . . . . . . . . . . .
. . . . CONNECTOR, clamp cable 1.250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . CABLE, weld cop strd No. 2/0 (order by ft) . . . . . . . . . . . . . . . . . . . . . . . .
. . . . CONNECTOR, twlk insul male (Tweco) . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . CONNECTOR, twlk insul fem (Tweco) (not supplied) . . . . . . . . . . . . . . .
. . . . BRACKET, mtg contactor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . CONTACTOR, 12VDC SPST on-off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . BOOT, insulator term post black 2/0 cable . . . . . . . . . . . . . . . . . . . . . . . .
. . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . TOOL, extraction pin Molex HT 60630-A . . . . . . . . . . . . . . . . . . . . . . . . . .
. . BUS BAR, interconnecting (not used w/contactor kit option) . . . . . . . . . . .
. . CONNECTOR, twlk uninsul male screw mount (Tweco)
(not used w/contactor kit option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . STAND–OFF, no. 6–32 X .750 lg .250 hex al m&f . . . . . . . . . . . . . . . . . . . .
. . CIRCUIT CARD, motor control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CONNECTOR & PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CONNECTOR & PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CONNECTOR & PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CONNECTOR & PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CLAMP, nyl .375clp dia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . HOSE, SAE .187 ID x .410 OD (order by ft) . . . . . . . . . . . . . . . . . . . . . . . .
. . GAS VALVE, 12 VDC (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . BRACKET, mtg valve gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
5
1
1
1ft
1ft
4
1
1
1
1ft
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
4ft
1
1
OM-184 517 Page 23
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 7-1. Complete Assembly (Continued)
. . 35 . . . . GS1 . . . . 128 074 . . . . VALVE, 12VDC 2 way custom port 1/8 orf . . . . . . . . . . . . . . . . . . . . . . . . .
. . 36 . . . . S4 . . . . . . 118 681 . . . . SWITCH, tgl DPDT 15A 125VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . PLG60 . . . 131 056 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . PLG62 . . . 131 055 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . 121 481 . . . . TOOL, extraction pin Molex HT 60630-A . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 37 . . . . . . . . . . . . ♦161 811 . . FLOW METER, gas (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 38 . . . . . . . . . . . . . 089 120 . . . . CLAMP, hose .375-.450clp dia slfttng . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 39 . . . . . . . . . . . . . 134 834 . . . . HOSE, SAE .187 ID x .410 OD (order by ft) . . . . . . . . . . . . . . . . . . . . . . .
. . 40 . . . . . . . . . . . . . . 112 090 . . . . FITTING, pipe brs elbow 1/8NPT x 3/16 hose . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . 056 108 . . . . FITTING, hose brs ferrule .450 ID x .718 lg . . . . . . . . . . . . . . . . . . . . . . .
. . 41 . . . . . . . . . . . . . . 111 569 . . . . METER, flow 6-60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 42 . . . . . . . . . . . . . 162 486 . . . . GUARD, flow meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 43 . . . . . . . . . . . . . 162 485 . . . . HOSE, gas output (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . 112 090 . . . . . . FITTING, pipe brs elbow 1/8NPT x 3/16 hose . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . 056 108 . . . . . . FITTING, hose brs ferrule .450 ID x .718 lg . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . 134 834 . . . . . . HOSE, SAE .187 ID x .410 OD (order by ft) . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . 079 196 . . . . . . FITTING, brs barbed fem 3/16tbg x 1/4NPT . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . 073 433 . . . . . . FITTING, brs barbed M 3/16tbg x 1/4NPT . . . . . . . . . . . . . . . . . . . . . . .
. . 44 . . . . . . . . . . . . . 134 230 . . BLANK, snap-in nyl .250mtg hole x 1.250 head . . . . . . . . . . . . . . . . . . . . . .
. . 45 . . . . . . . . . . . . . 134 233 . . WASHER, fbr .281 ID x .781 OD x .125thk . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . 134 232 . . WASHER, fbr .281 ID x 1.031 OD x .125thk . . . . . . . . . . . . . . . . . . . . . . . . .
. . 46 . . . . . . . . . . . . . 089 572 . . CATCH, link lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 47 . . . . . . . . . . . . . 178 936 . . LABEL, warning general precautionary . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 48 . . . . . . . . . . . . . 126 416 . . HANDLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 49 . . . . . . . . . . . . . 126 415 . . CLAMP, saddle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 50 . . . . . . . . . . . . . 134 231 . . WASHER, fbr .250 ID x 1.250 OD x .125thk . . . . . . . . . . . . . . . . . . . . . . . . .
. . 51 . . . . . . . . . . . . . 180 560 . . LABEL, warning electric shock can kill . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 52 . . . . . . . . . . . . +138 582 . . CASE, control feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 53 . . . . . . . . . . . . . 090 099 . . INSULATOR, gun holder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 54 . . . . . . . . . . . . . 044 800 . . WASHER, spring grip locking .750sft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 55 . . . . . . . . . . . . . 049 455 . . CABLE, port No. 18 2/c (order by ft) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 56 . . . . . . . . . . . . . 048 834 . . CONNECTOR, circ clamp str rlf sz 11 Amp 206062-4 . . . . . . . . . . . . . . . .
. . 57 . . . PLG1 . . . 080 328 . . CONNECTOR w/SOCKETS, free hanging . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 58 . . . . . . . . . . . . . 126 693 . . CABLE, sensing 15ft (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . 601 222 . . . . CLAMP, universal 50A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . 601 225 . . . . INSULATOR, vyl clamp blk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 59 . . . . . . . . . . . . . 126 308 . . HINGE, cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 60 . . . . . . . . . . . . ♦161 241 . . METER, V/WFS (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 61 . . . . PC4 . . . . 162 223 . . . . CIRCUIT CARD, meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . PLG40 . . . 163 467 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . PLG41 . . . 153 501 . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 62 . . . . . . . . . . . . . 091 961 . . . . METER, volt DC 0-10 scale . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 63 . . . . . . . . . . . . . 091 962 . . . . METER, IPM 0-10MV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 64 . . . . S1 . . . . . . 111 997 . . SWITCH, rocker SPST 10A 250VAC on-off . . . . . . . . . . . . . . . . . . . . . . . . .
. . 65 . . . . . . . . . . . . . 097 922 . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 66 . . . . . . . . . . . . . . . . . . . . . . . . NAMEPLATE, (order by model and serial number) . . . . . . . . . . . . . . . . . . .
. . 67 . . . . . . . . . . . . . 176 177 . . PANEL, front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 68 . . . . S5 . . . . . . 011 622 . . SWITCH, tgl 3PDT 15A 125VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 69 . . . R100 . . . 073 562 . . POTENTIOMETER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 70 . . . . . . . . . . . . . 168 246 . . COVER, control/feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 71 . . . . . . . . . . . . . 109 155 . . NUT, speed U type10-32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 72 . . . . . . . . . . . . . 131 604 . . BRACKET, cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 73 . . . . . . . . . . . . . 071 602 . . LABEL, caution HF will damage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 75 . . . . . . . . . . . . +138 581 . . COVER, control/feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 75 . . . . . . . . . . . +*175 156 . . COVER, control/feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 76 . . . . . . . . . . . . . 089 573 . . PLATE, keeper link lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 77 . . . . . . . . . . . . . 089 556 . . INSULATION, motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 78 . . . . . . . . . . . . . 144 172 . . FITTING, brs barbed M 3/16tbg x .250-20 . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-184 517 Page 24
1
1
1
1
1
1
2
2ft
1
1
1
1
1
1
2
1ft
1
1
2
1
1
2
1
1
1
2
1
1
1
1
2ft
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 7-1. Complete Assembly (Continued)
. . 79 . . . . . . . . . . . . . 604 538
. . 80 . . . . . . . . . . . . . 124 778
. . 81 . . . . . . . . . . . . . 151 828
. . 82 . . . . . . . . . . . . . 089 555
. . 83 . . . . . . . . . . . . . 166 338
. . 84 . . . . . . . . . . . . . 166 072
. . 85 . . . . . . . . . . . . . 172 075
. . 86 . . . . . . . . . . . . . 079 625
. . 87 . . . . . . . . . . . . . 172 076
. . 88 . . . . . . . . . . . . . 092 865
. . 89 . . . . . . . . . . . . . 010 224
. . 90 . . . . . . . . . . . . . 054 263
. . 91 . . . . . . . . . . . . . 085 243
. . 92 . . . . . . . . . . . . . 089 477
. . 93 . . . . . . . . . . . . . 085 244
. . 94 . . . . . . . . . . . . . 089 562
. . 95 . . . . . . . . . . . . . 601 964
. . 96 . . . . . . . . . . . . . 602 213
. . 97 . . . . . M . . . . . 160 816
. . . . . . . . . . . . . . . . . . **095 564
. . . . . . . . . . . . . . . . . . . 095 565
. . 98 . . . . . . . . . . . . . 081 895
. . 99 . . . . SR1 . . . . 035 704
. 100 . . . . . . . . . . . . . 126 764
. 101 . C100,101 . . . 111 441
. 102 . . . . . . . . . . . . . 126 312
. 103 . . . . . . . . . . . . . 134 201
. . WASHER, flat stl SAE .312 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . KNOB, plstc T 1.000 lg x .312-18 x 2.000 bar . . . . . . . . . . . . . . . . . . . . . . .
. . PIN, cotter hair .054 x .750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . PIN, hinge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . LEVER, mtg pressure gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . SPACER, gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CARRIER, drive roll w/components 24 pitch . . . . . . . . . . . . . . . . . . . . . . . . .
. . WASHER, spring stl .500 shakeproof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CARRIER, drive roll w/components keyed 24 pitch . . . . . . . . . . . . . . . . . . .
. . KEY, stl .1215/.1230 x .750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . PIN, spring CS .187 x 1.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . SCREW, thumb stl .250-20 x .500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . KNOB, adj tension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . SPRING, cprsn .770 OD x .100 wire x .715 . . . . . . . . . . . . . . . . . . . . . . . . .
. . WASHER, cupped stl .328 ID x .812 OD x .125 lip . . . . . . . . . . . . . . . . . . .
. . FASTENER, pinned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . SCREW, cap stl hexhd .375-16 x .750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . WASHER, lock stl split .375 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . MOTOR, 24VDC 5.2A 118RPM (consisting of) . . . . . . . . . . . . . . . . . . . . . .
. . . . BRUSH, motor carbon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . CAP, brush motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . NUT, well 10-32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . RECTIFIER, integ 40A 800V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . INSULATOR, capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CAPACITOR, elctlt 1200uf 250VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . STRIP, mtg capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . STAND-OFF SUPPORT, PC card .312/.375W/post&lock . . . . . . . . . . . . .
1
1
2
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
2
2
5
1
1
2
1
4
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
♦OPTIONAL
*Part of 183 710 Contactor Kit Option.
**Recommended Spare Parts.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-184 517 Page 25
Table 7-1. Drive Roll & Wire Guide Kits (2 Drive Roll)
NOTE
Base selection of drive rolls upon the following recommended usages:
1. V-Grooved rolls for hard wire.
2. U-Grooved rolls for soft and soft shelled cored wires.
3. U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types).
4. V-Knurled rolls for hard shelled cored wires.
5. Drive roll types may be mixed to suit particular requirements (example:
V-Knurled roll in combination with U-Grooved).
Wire Diameter
Fraction
Decimal
Metric
Kit No.
Drive Roll
Part No.
Type
Inlet
Wire Guide
.023/.025 in
.023/.025 in
0.6 mm
087 131
087 130
V-Grooved
056 192
.030 in
.030 in
0.8 mm
079 594
053 695
V-Grooved
056 192
.035 in
.035 in
0.9 mm
079 595
053 700
V-Grooved
056 192
.040 in
.040 in
1.0 mm
161 189
053 696
V-Grooved
056 192
.045 in
.045 in
1.2 mm
079 596
053 697
V-Grooved
056 193
.052 in
.052 in
1.3 mm
079 597
053 698
V-Grooved
056 193
1/16 in
.062 in
1.6 mm
079 598
053 699
V-Grooved
056 195
.035 in
.035 in
0.9 mm
044 749
072 000
U-Grooved
056 192
.045 in
.045 in
1.2 mm
079 599
053 701
U-Grooved
056 193
.052 in
.052 in
1.3 mm
079 600
053 702
U-Grooved
056 193
1/16 in
5/64 in
.062 in
.079 in
1.6 mm
2.0 mm
079 601
079 602
053 706
053 704
U-Grooved
U-Grooved
056 195
056 195
.035 in
.035 in
0.9 mm
079 606
132 958
V-Knurled
056 192
.045 in
.045 in
1.2 mm
079 607
132 957
V-Knurled
056 193
.052 in
.052 in
1.3 mm
079 608
132 956
V-Knurled
056 193
1/16 in
.062 in
1.6 mm
079 609
132 955
V-Knurled
056 195
.068-.072 in
.068-.072
1.8 mm
089 984
132 959
V-Knurled
056 195
5/64 in
.079 in
2.0 mm
079 610
132 960
V-Knurled
056 195
.045 in
.045 in
1.2 mm
083 318
083 489
U-Cogged
056 193
.052 in
.052 in
1.3 mm
083 317
083 490
U-Cogged
056 193
1/16 in
.062 in
1.6 mm
079 614
053 708
U-Cogged
056 195
5/64 in
.079 in
2.0 mm
079 615
053 710
U-Cogged
056 195
S-0859
OM-184 517 Page 26
Dia.
Mkgs.
Part
No.
Description
Quantity
Optional Equipment
...............
...............
. . . . PC5 . . . . . .
...............
...............
. . . PLG60 . . . .
. . . PLG63 . . . .
. . . PLG69 . . . .
...............
. . . PLG70 . . . .
...............
...............
. . . PLG71 . . . .
...............
...............
...............
. . . PLG73 . . . .
. . . PLG74 . . . .
. . . . R101 . . . . .
...............
. . . RC74 . . . . .
...............
...............
...............
130 676
130 686
132 253
132 545
070 026
131 056
115 093
131 059
132 587
115 093
115 104
110 015
141 162
079 739
121 481
121 482
115 092
131 204
035 897
097 922
131 203
161 241
161 809
161 811
. . CONTACTOR KIT, (see Figure 7-1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . REMOTE CONTACTOR/VOLTAGE CONTROL, (consisting of) . . . . . . . . . . . .
. . . . CIRCUIT CARD, remote contactor relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . BRACKET, mtg relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . STAND-OFF, 6-32 x .437 lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . CONNECTOR & PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . CABLE, contactor/voltage control (consisting of) . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . CONNECTOR, clamp cable .500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . CABLE, port No. 18 7/c (order by ft) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . CONNECTOR & PINS, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . CONNECTOR, circ clamp str rlf sz 17-20 Amp 206322-2 . . . . . . . . . . . .
. . . . . . TOOL, extraction pin Molex HT 60630-A . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . TOOL, extraction pin Amphenol No. 356-263 . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . POTENTIOMETER, CP std slot 1/T 2W 1K ohm . . . . . . . . . . . . . . . . . . . . . . .
. . . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . CONNECTOR & PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . METERS, V/WFS (see Figure 7-1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . GAS VALVE, 12 VDC (see Figure 7-1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . FLOW METER, gas (see Figure 7-1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
1
3
1
1
1
1
1
1
2ft
1
1
1
1
1
1
1
1
1
1
1
1
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-184 517 Page 27
Notes
OM-184 517 Page 28
Notes
OM-184 517 Page 29
Notes
OM-184 517 Page 30
Effective January 1, 2000
(Equipment with a serial number preface of “LA” or newer)
This limited warranty supersedes all previous Miller warranties and is exclusive with no other
guarantees or warranties expressed or implied.
Warranty Questions?
Call
1-800-4-A-MILLER
for your local
Miller distributor.
Your distributor also gives
you ...
Service
You always get the fast,
reliable response you
need. Most replacement
parts can be in your
hands in 24 hours.
Support
Need fast answers to the
tough welding questions?
Contact your distributor.
The expertise of the
distributor and Miller is
there to help you, every
step of the way.
*
LIMITED WARRANTY – Subject to the terms and conditions
below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants
to its original retail purchaser that new Miller equipment sold
after the effective date of this limited warranty is free of defects
in material and workmanship at the time it is shipped by Miller.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS.
Within the warranty periods listed below, Miller will repair or
replace any warranted parts or components that fail due to
such defects in material or workmanship. Miller must be
notified in writing within thirty (30) days of such defect or
failure, at which time Miller will provide instructions on the
warranty claim procedures to be followed.
Miller shall honor warranty claims on warranted equipment
listed below in the event of such a failure within the warranty
time periods. All warranty time periods start on the date that
the equipment was delivered to the original retail purchaser, or
one year after the equipment is sent to a North American
distributor or eighteen months after the equipment is sent to an
International distributor.
1.
5 Years Parts – 3 Years Labor
*
*
2.
3 Years — Parts and Labor
*
*
*
*
*
*
3.
Original main power rectifiers
Inverters (input and output rectifiers only)
Transformer/Rectifier Power Sources
Plasma Arc Cutting Power Sources
Semi-Automatic and Automatic Wire Feeders
Inverter Power Supplies
Intellitig
Engine Driven Welding Generators
(NOTE: Engines are warranted separately by
the engine manufacturer.)
1 Year — Parts and Labor
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
DS-2 Wire Feeder
Motor Driven Guns (w/exception of Spoolmate
185 & Spoolmate 250)
Process Controllers
Positioners and Controllers
Automatic Motion Devices
RFCS Foot Controls
Induction Heating Power Sources
Water Coolant Systems
HF Units
Grids
Maxstar 140
Spot Welders
Load Banks
Miller Cyclomatic Equipment
Running Gear/Trailers
Plasma Cutting Torches (except APT & SAF
Models)
Field Options
(NOTE: Field options are covered under True
Blue for the remaining warranty period of the
product they are installed in, or for a minimum of
one year — whichever is greater.)
4.
6 Months — Batteries
5.
90 Days — Parts
*
*
MIG Guns/TIG Torches
Induction Heating Coils and Blankets
*
*
*
*
*
APT, ZIPCUT & PLAZCUT Model Plasma Cutting
Torches
Remote Controls
Accessory Kits
Replacement Parts (No labor)
Spoolmate 185 & Spoolmate 250
Canvas Covers
Miller’s True Blue Limited Warranty shall not apply to:
1.
Consumable components; such as contact tips,
cutting nozzles, contactors, brushes, slip rings,
relays or parts that fail due to normal wear.
2.
Items furnished by Miller, but manufactured by others,
such as engines or trade accessories. These items are
covered by the manufacturer’s warranty, if any.
3.
Equipment that has been modified by any party other
than Miller, or equipment that has been improperly
installed, improperly operated or misused based upon
industry standards, or equipment which has not had
reasonable and necessary maintenance, or equipment
which has been used for operation outside of the
specifications for the equipment.
MILLER PRODUCTS ARE INTENDED FOR PURCHASE
AND USE BY COMMERCIAL/INDUSTRIAL USERS AND
PERSONS TRAINED AND EXPERIENCED IN THE USE
AND MAINTENANCE OF WELDING EQUIPMENT.
In the event of a warranty claim covered by this warranty, the
exclusive remedies shall be, at Miller’s option: (1) repair; or (2)
replacement; or, where authorized in writing by Miller in
appropriate cases, (3) the reasonable cost of repair or
replacement at an authorized Miller service station; or (4)
payment of or credit for the purchase price (less reasonable
depreciation based upon actual use) upon return of the goods
at customer’s risk and expense. Miller’s option of repair or
replacement will be F.O.B., Factory at Appleton, Wisconsin, or
F.O.B. at a Miller authorized service facility as determined by
Miller. Therefore no compensation or reimbursement for
transportation costs of any kind will be allowed.
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR
DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF
PROFIT), WHETHER BASED ON CONTRACT, TORT OR
ANY OTHER LEGAL THEORY.
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN
AND ANY IMPLIED WARRANTY, GUARANTY OR
REPRESENTATION AS TO PERFORMANCE, AND ANY
REMEDY FOR BREACH OF CONTRACT TORT OR ANY
OTHER LEGAL THEORY WHICH, BUT FOR THIS
PROVISION,
MIGHT
ARISE
BY
IMPLICATION,
OPERATION OF LAW, CUSTOM OF TRADE OR COURSE
OF DEALING, INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR PARTICULAR
PURPOSE, WITH RESPECT TO ANY AND ALL
EQUIPMENT FURNISHED BY MILLER IS EXCLUDED AND
DISCLAIMED BY MILLER.
Some states in the U.S.A. do not allow limitations of how long
an implied warranty lasts, or the exclusion of incidental,
indirect, special or consequential damages, so the above
limitation or exclusion may not apply to you. This warranty
provides specific legal rights, and other rights may be
available, but may vary from state to state.
In Canada, legislation in some provinces provides for certain
additional warranties or remedies other than as stated herein,
and to the extent that they may not be waived, the limitations
and exclusions set out above may not apply. This Limited
Warranty provides specific legal rights, and other rights may
be available, but may vary from province to province.
miller_warr 7/00
Owner’s Record
Please complete and retain with your personal records.
Model Name
Serial/Style Number
Purchase Date
(Date which equipment was delivered to original customer.)
Distributor
Address
City
State
Zip
For Service
Call 1-800-4-A-Miller or see our website at www.MillerWelds.com
to locate a DISTRIBUTOR or SERVICE AGENCY near you.
Always provide Model Name and Serial/Style Number.
Contact your Distributor for:
Welding Supplies and Consumables
Options and Accessories
Personal Safety Equipment
Service and Repair
Miller Electric Mfg. Co.
An Illinois Tool Works Company
1635 West Spencer Street
Appleton, WI 54914 USA
Replacement Parts
Training (Schools, Videos, Books)
International Headquarters–USA
USA Phone: 920-735-4505 Auto-Attended
USA & Canada FAX: 920-735-4134
International FAX: 920-735-4125
Technical Manuals (Servicing Information
and Parts)
Circuit Diagrams
European Headquarters –
United Kingdom
Phone: 44 (0) 1204-593493
FAX: 44 (0) 1204-598066
Welding Process Handbooks
www.MillerWelds.com
Contact the Delivering Carrier for:
File a claim for loss or damage during
shipment.
For assistance in filing or settling claims,
contact your distributor and/or equipment
manufacturer’s Transportation Department.
PRINTED IN USA
 2000 Miller Electric Mfg. Co.
6/00

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project