Miller | LC698420 | Owner Manual | Miller SUITCASE 12RC CE User manual

Miller SUITCASE 12RC CE User manual
OM-1500−15
210 177D
November 2003
Processes
MIG (GMAW) Welding
Flux Cored (FCAW) Welding
Description
Wire Feeder
SuitCase 12RC
Visit our website at
www.MillerWelds.com
From Miller to You
Thank you and congratulations on choosing Miller. Now you can get
the job done and get it done right. We know you don’t have time to do
it any other way.
That’s why when Niels Miller first started building arc welders in 1929,
he made sure his products offered long-lasting value and superior
quality. Like you, his customers couldn’t afford anything less. Miller
products had to be more than the best they could be. They had to be the
best you could buy.
Today, the people that build and sell Miller products continue the
tradition. They’re just as committed to providing equipment and service
that meets the high standards of quality and value established in 1929.
This Owner’s Manual is designed to help you get the most out of your
Miller products. Please take time to read the Safety precautions. They
will help you protect yourself against potential hazards on the worksite.
We’ve made installation and operation quick
and easy. With Miller you can count on years
of reliable service with proper maintenance.
And if for some reason the unit needs repair,
there’s a Troubleshooting section that will
help you figure out what the problem is. The
Miller is the first welding parts list will then help you to decide the
equipment manufacturer in exact part you may need to fix the problem.
the U.S.A. to be registered to
the ISO 9001:2000 Quality Warranty and service information for your
System Standard.
particular model are also provided.
Miller Electric manufactures a full line
of welders and welding related equipment.
For information on other quality Miller
products, contact your local Miller distributor to receive the latest full
line catalog or individual catalog sheets. To locate your nearest
distributor or service agency call 1-800-4-A-Miller, or visit us at
www.MillerWelds.com on the web.
Mil_Thank 7/03
Working as hard as you do
− every power source from
Miller is backed by the most
hassle-free warranty in the
business.
TABLE OF CONTENTS
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4. California Proposition 65 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-6. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 − CONSIGNES DE SÉCURITÉ − À LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1. Signification des symboles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2. Dangers relatifs au soudage à l’arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3. Autres symboles relatifs à l’installation, au fonctionnement et à l’entretien de l’appareil. . . . . . . . . . . .
2-4. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-5. Information sur les champs électromagnétiques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 − DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1. Warning Label Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2. Manufacturer’s Rating Label For CE Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-3. Symbols And Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 4 − INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. 14-Pin Plug Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3. Gun Recommendation Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-4. Equipment Connection Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-5. Installing And Aligning Wire Guide And Drive Rolls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-6. Connecting Welding Gun . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-7. Connecting Shielding Gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-8. Connecting Weld Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-9. Installing And Threading Welding Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 5 − OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-1. Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2. Controls For Meter (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-3. Controls For CE Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-4. Setting Digital Meter Board PC4 DIP Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-5. Gun Consumables Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 − MAINTENANCE & TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-2. Overload Protection And Thermostat Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-3. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 7 − ELECTRICAL DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 8 − PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPTIONS AND ACCESSORIES
WARRANTY
1
1
1
3
3
4
4
5
5
5
7
8
8
9
9
10
10
10
10
11
11
11
12
13
13
14
14
15
15
16
16
17
18
19
19
19
20
21
22
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING
som _8/03
1-1. Symbol Usage
Means Warning! Watch Out! There are possible hazards
with this procedure! The possible hazards are shown in
the adjoining symbols.
This group of symbols means Warning! Watch Out! possible
ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.
Consult symbols and related instructions below for necessary actions
to avoid the hazards.
Y Marks a special safety message.
. Means “Note”; not safety related.
1-2. Arc Welding Hazards
Y The symbols shown below are used throughout this manual to
call attention to and identify possible hazards. When you see
the symbol, watch out, and follow the related instructions to
avoid the hazard. The safety information given below is only
a summary of the more complete safety information found in
the Safety Standards listed in Section 1-5. Read and follow all
Safety Standards.
D If earth grounding of the workpiece is required, ground it directly
with a separate cable.
Y Only qualified persons should install, operate, maintain, and
repair this unit.
D Wear a safety harness if working above floor level.
D Keep all panels and covers securely in place.
Y During operation, keep everybody, especially children, away.
D Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
D Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
D Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
D Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shocks
or severe burns. The electrode and work circuit is
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also
live when power is on. In semiautomatic or automatic wire welding, the
wire, wire reel, drive roll housing, and all metal parts touching the
welding wire are electrically live. Incorrectly installed or improperly
grounded equipment is a hazard.
D Do not connect more than one electrode or work cable to any
single weld output terminal.
SIGNIFICANT DC VOLTAGE exists after removal of
input power on inverters.
D Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section
before touching any parts.
D Do not touch live electrical parts.
D Wear dry, hole-free insulating gloves and body protection.
D Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.
D Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
D Use AC output ONLY if required for the welding process.
D If AC output is required, use remote output control if present on
unit.
D Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
D Properly install and ground this equipment according to its
Owner’s Manual and national, state, and local codes.
D Keep your head out of the fumes. Do not breathe the fumes.
D Always verify the supply ground − check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
grounded receptacle outlet.
D When making input connections, attach proper grounding conductor first − double-check connections.
D Frequently inspect input power cord for damage or bare wiring −
replace cord immediately if damaged − bare wiring can kill.
D Turn off all equipment when not in use.
D Do not use worn, damaged, undersized, or poorly spliced cables.
D Do not weld in locations near degreasing, cleaning, or spraying operations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.
D Do not drape cables over your body.
FUMES AND GASES can be hazardous.
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health.
D If inside, ventilate the area and/or use exhaust at the arc to remove
welding fumes and gases.
D If ventilation is poor, use an approved air-supplied respirator.
D Read the Material Safety Data Sheets (MSDSs) and the
manufacturer’s instructions for metals, consumables, coatings,
cleaners, and degreasers.
D Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watchperson nearby. Welding fumes and gases can displace air and
lower the oxygen level causing injury or death. Be sure the breathing air is safe.
D Do not weld on coated metals, such as galvanized, lead, or
cadmium plated steel, unless the coating is removed from the weld
area, the area is well ventilated, and if necessary, while wearing an
air-supplied respirator. The coatings and any metals containing
these elements can give off toxic fumes if welded.
Return To Table Of Contents
OM-1500-15 Page 1
ARC RAYS can burn eyes and skin.
BUILDUP OF GAS can injure or kill.
D Shut off shielding gas supply when not in use.
D Always ventilate confined spaces or use
approved air-supplied respirator.
Arc rays from the welding process produce intense
visible and invisible (ultraviolet and infrared) rays
that can burn eyes and skin. Sparks fly off from the
weld.
D Wear a welding helmet fitted with a proper shade of filter to protect
your face and eyes when welding or watching (see ANSI Z49.1
and Z87.1 listed in Safety Standards).
HOT PARTS can cause severe burns.
D Wear approved safety glasses with side shields under your
helmet.
D Use protective screens or barriers to protect others from flash and
glare; warn others not to watch the arc.
D Wear protective clothing made from durable, flame-resistant material (leather and wool) and foot protection.
D Do not touch hot parts bare handed.
D Allow cooling period before working on gun or
torch.
MAGNETIC FIELDS can affect pacemakers.
WELDING can cause fire or explosion.
D Pacemaker wearers keep away.
D Wearers should consult their doctor before
going near arc welding, gouging, or spot
welding operations.
Welding on closed containers, such as tanks,
drums, or pipes, can cause them to blow up. Sparks
can fly off from the welding arc. The flying sparks, hot
workpiece, and hot equipment can cause fires and
burns. Accidental contact of electrode to metal objects can cause
sparks, explosion, overheating, or fire. Check and be sure the area is
safe before doing any welding.
D Protect yourself and others from flying sparks and hot metal.
D Do not weld where flying sparks can strike flammable material.
D Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
D Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
D Watch for fire, and keep a fire extinguisher nearby.
D Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
D Do not weld on closed containers such as tanks, drums, or pipes,
unless they are properly prepared according to AWS F4.1 (see
Safety Standards).
D Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly
unknown paths and causing electric shock and fire hazards.
D Do not use welder to thaw frozen pipes.
D Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
D Wear oil-free protective garments such as leather gloves, heavy
shirt, cuffless trousers, high shoes, and a cap.
D Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.
FLYING METAL can injure eyes.
D Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool,
they can throw off slag.
D Wear approved safety glasses with side
shields even under your welding helmet.
OM-1500-15 Page 2
NOISE can damage hearing.
Noise from some processes or equipment can
damage hearing.
D Wear approved ear protection if noise level is
high.
CYLINDERS can explode if damaged.
Shielding gas cylinders contain gas under high
pressure. If damaged, a cylinder can explode. Since
gas cylinders are normally part of the welding
process, be sure to treat them carefully.
D Protect compressed gas cylinders from excessive heat, mechanical shocks, slag, open flames, sparks, and arcs.
D Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
D Keep cylinders away from any welding or other electrical circuits.
D Never drape a welding torch over a gas cylinder.
D Never allow a welding electrode to touch any cylinder.
D Never weld on a pressurized cylinder − explosion will result.
D Use only correct shielding gas cylinders, regulators, hoses, and fittings designed for the specific application; maintain them and
associated parts in good condition.
D Turn face away from valve outlet when opening cylinder valve.
D Keep protective cap in place over valve except when cylinder is in
use or connected for use.
D Read and follow instructions on compressed gas cylinders,
associated equipment, and CGA publication P-1 listed in Safety
Standards.
Return To Table Of Contents
1-3. Additional Symbols For Installation, Operation, And Maintenance
FIRE OR EXPLOSION hazard.
MOVING PARTS can cause injury.
D Do not install or place unit on, over, or near
combustible surfaces.
D Do not install unit near flammables.
D Do not overload building wiring − be sure power supply system is
properly sized, rated, and protected to handle this unit.
D Keep away from moving parts such as fans.
D Keep all doors, panels, covers, and guards
closed and securely in place.
FALLING UNIT can cause injury.
H.F. RADIATION can cause interference.
D Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
D Use equipment of adequate capacity to lift and
support unit.
D If using lift forks to move unit, be sure forks are
long enough to extend beyond opposite side of
unit.
D
OVERUSE can cause OVERHEATING
D
D Allow cooling period; follow rated duty cycle.
D Reduce current or reduce duty cycle before
starting to weld again.
D Do not block or filter airflow to unit.
D
D
D High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communications equipment.
D Have only qualified persons familiar with
electronic equipment perform this installation.
The user is responsible for having a qualified electrician promptly correct any interference problem resulting from the installation.
If notified by the FCC about interference, stop using the
equipment at once.
Have the installation regularly checked and maintained.
Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.
STATIC (ESD) can damage PC boards.
D Put on grounded wrist strap BEFORE handling
boards or parts.
D Use proper static-proof bags and boxes to
store, move, or ship PC boards.
ARC WELDING can cause interference.
MOVING PARTS can cause injury.
D Keep away from moving parts.
D Keep away from pinch points such as drive
rolls.
D
D
WELDING WIRE can cause injury.
D Do not press gun trigger until instructed to do
so.
D Do not point gun toward any part of the body,
other people, or any metal when threading
welding wire.
D
D
D Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.
D Be sure all equipment in the welding area is
electromagnetically compatible.
To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
Locate welding operation 100 meters from any sensitive electronic equipment.
Be sure this welding machine is installed and grounded
according to this manual.
If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables,
using line filters, or shielding the work area.
1-4. California Proposition 65 Warnings
Y Welding or cutting equipment produces fumes or gases which
contain chemicals known to the State of California to cause
birth defects and, in some cases, cancer. (California Health &
Safety Code Section 25249.5 et seq.)
For Gasoline Engines:
Y Engine exhaust contains chemicals known to the State of
California to cause cancer, birth defects, or other reproductive
harm.
Y Battery posts, terminals and related accessories contain lead
and lead compounds, chemicals known to the State of
California to cause cancer and birth defects or other
reproductive harm. Wash hands after handling.
For Diesel Engines:
Y Diesel engine exhaust and some of its constituents are known
to the State of California to cause cancer, birth defects, and
other reproductive harm.
Return To Table Of Contents
OM-1500-15 Page 3
1-5. Principal Safety Standards
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
from American Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126
(phone: 305-443-9353, website: www.aws.org).
Boulevard, Rexdale, Ontario, Canada M9W 1R3 (phone:
800−463−6727 or in Toronto 416−747−4044, website: www.csa−international.org).
Recommended Safe Practices for the Preparation for Welding and Cutting of Containers and Piping, American Welding Society Standard
AWS F4.1, from American Welding Society, 550 N.W. LeJeune Rd, Miami, FL 33126 (phone: 305-443-9353, website: www.aws.org).
Practice For Occupational And Educational Eye And Face Protection,
ANSI Standard Z87.1, from American National Standards Institute, 11
West 42nd Street, New York, NY 10036−8002 (phone: 212−642−4900,
website: www.ansi.org).
National Electrical Code, NFPA Standard 70, from National Fire Protection Association, P.O. Box 9101, 1 Battery March Park, Quincy, MA
02269−9101 (phone: 617−770−3000, website: www.nfpa.org and www.
sparky.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, from National Fire Protection Association,
P.O. Box 9101, 1 Battery March Park, Quincy, MA 02269−9101 (phone:
617−770−3000,website: www.nfpa.org and www. sparky.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 1735 Jefferson Davis Highway,
Suite 1004, Arlington, VA 22202−4102 (phone: 703−412−0900, website: www.cganet.com).
Code for Safety in Welding and Cutting, CSA Standard W117.2, from
Canadian Standards Association, Standards Sales, 178 Rexdale
OSHA, Occupational Safety and Health Standards for General Industry, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,
and Part 1926, Subpart J, from U.S. Government Printing Office, Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250 (there
are 10 Regional Offices−−phone for Region 5, Chicago, is
312−353−2220,website: www.osha.gov).
1-6. EMF Information
Considerations About Welding And The Effects Of Low Frequency
Electric And Magnetic Fields
Welding current, as it flows through welding cables, will cause electromagnetic fields. There has been and still is some concern about such
fields. However, after examining more than 500 studies spanning 17
years of research, a special blue ribbon committee of the National
Research Council concluded that: “The body of evidence, in the
committee’s judgment, has not demonstrated that exposure to powerfrequency electric and magnetic fields is a human-health hazard.”
However, studies are still going forth and evidence continues to be
examined. Until the final conclusions of the research are reached, you
may wish to minimize your exposure to electromagnetic fields when
welding or cutting.
To reduce magnetic fields in the workplace, use the following
procedures:
OM-1500-15 Page 4
1. Keep cables close together by twisting or taping them.
2. Arrange cables to one side and away from the operator.
3. Do not coil or drape cables around your body.
4. Keep welding power source and cables as far away from operator as practical.
5. Connect work clamp to workpiece as close to the weld as possible.
About Pacemakers:
Pacemaker wearers consult your doctor first. If cleared by your doctor,
then following the above procedures is recommended.
Return To Table Of Contents
SECTION 2 − CONSIGNES DE SÉCURITÉ − À LIRE AVANT
UTILISATION
som_fre 8/03
2-1. Signification des symboles
Signifie « Mise en garde. Faire preuve de vigilance. »
Cette procédure présente des risques identifiés par les
symboles adjacents aux directives.
Ce groupe de symboles signifie « Mise en garde. Faire preuve de vigilance. » Il y a des dangers liés aux CHOCS ÉLECTRIQUES, aux
PIÈCES EN MOUVEMENT et aux PIÈCES CHAUDES. Se reporter
aux symboles et aux directives ci-dessous afin de connaître les mesures à prendre pour éviter tout danger.
Y Identifie un message de sécurité particulier.
. Signifie « NOTA » ; n’est pas relatif à la sécurité.
2-2. Dangers relatifs au soudage à l’arc
Y Les symboles ci-après sont utilisés tout au long du présent
manuel pour attirer l’attention sur les dangers potentiels et les
identifier. Lorsqu’on voit un symbole, faire preuve de vigilance et
suivre les directives mentionnées afin d’éviter tout danger. Les
consignes de sécurité énoncées ci-après ne font que résumer le
contenu des normes de sécurité mentionnées à la section 2-4.
Lire et respecter toutes ces normes.
D N’utiliser que du matériel en bon état. Réparer ou remplacer sur−le−
champ les pièces endommagées. Entretenir l’appareil conformément
au présent manuel.
Y L’installation, l’utilisation, l’entretien et les réparations ne doivent être confiés qu’à des personnes qualifiées.
D Fixer le câble de retour de façon à obtenir un bon contact métal sur
métal avec la pièce à souder ou la table de travail, le plus près possible
de la soudure.
Y Pendant l’utilisation de l’appareil, tenir à l’écart toute personne,
en particulier les enfants.
D Porter un harnais de sécurité quand on travaille en hauteur.
D Maintenir solidement en place tous les panneaux et capots.
D
Ne pas connecter plus d’une électrode ou plus d’un câble de masse à un
même terminal de sortie.
LES DÉCHARGES ÉLECTRIQUES
peuvent être mortelles.
Un simple contact avec des pièces sous tension peut
causer une électrocution ou des blessures graves.
L’électrode et le circuit de soudage sont sous tension
dès que l’appareil est en fonctionnement. Le circuit
d’entrée et les circuits internes de l’appareil sont également sous tension.
En soudage semi−automatique ou automatique, le fil, le dévidoir, le
logement des galets d’entraînement et les pièces métalliques en contact
avec le fil de soudage sont sous tension. Tout matériel mal installé ou mal
mis à la terre présente un danger.
Il subsiste un COURANT CONTINU IMPORTANT
dans les convertisseurs après la suppression de
l’alimentation électrique.
D Arrêter les convertisseurs, débrancher le courant électrique et décharger les condensateurs d’alimentation selon les instructions
énoncées à la section Entretien avant de toucher les pièces.
D Ne jamais toucher aux pièces électriques sous tension.
D Porter des gants et des vêtements de protection secs et exempts de
trous.
D S’isoler de la pièce et de la terre au moyen de tapis ou autres dispositifs isolants suffisamment grands pour empêcher tout contact
physique avec la pièce ou la terre.
D
D
D
Ne pas se servir d’une source de courant alternatif dans les zones humides, les endroits confinés ou là où on risque de tomber.
Ne se servir d’une source de courant alternatif QUE si le procédé de soudage l’exige.
Si l’utilisation d’une source de courant alternatif s’avère nécessaire, se servir de la fonction de télécommande si l’appareil en est équipé.
D Couper l’alimentation ou arrêter le moteur avant de procéder à l’installation, à la réparation ou à l’entretien de l’appareil. Couper/étiqueter
l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir les normes de sécurité).
D Installer et mettre à la terre correctement l’appareil conformément à
son manuel d’utilisation et aux codes nationaux, provinciaux et
municipaux.
D Toujours vérifier la terre du cordon d’alimentation − Vérifier et s’assurer que le fil de terre du cordon d’alimentation est bien raccordé à la
borne de terre du sectionneur ou que la fiche du cordon est raccordée
à une prise correctement mise à la terre.
D Pour exécuter les branchements d’entrée, fixer d’abord le conducteur
de mise à la terre adéquat et contre−vérifier les connexions.
D Vérifier fréquemment le cordon d’alimentation et s’assurer qu’il n’est
ni endommagé ni dénudé ; le remplacer immédiatement s’il est endommagé − tout câble dénudé peut causer une électrocution.
D Mettre l’appareil hors tension quand on ne l’utilise pas.
D Ne pas utiliser de câbles usés, endommagés, de calibre insuffisant ou
mal épissés.
D Ne pas s’enrouler les câbles autour du corps.
D Si la pièce soudée doit être mise à la terre, le faire directement avec un
câble distinct.
D Ne pas toucher l’électrode quand on est en contact avec la pièce, la
terre ou une électrode d’une autre machine.
LES FUMÉES ET LES GAZ peuvent
être dangereux.
Le soudage génère des fumées et des gaz dont
l’inhalation peut être dangereuse pour la santé.
D Se tenir à distance des fumées et ne pas les inhaler.
D À l’intérieur, ventiler la zone et/ou utiliser un dispositif d’aspiration au
niveau de l’arc pour l’évacuation des fumées et des gaz de soudage.
D Si la ventilation est insuffisante, utiliser un respirateur à adduction
d’air agréé.
D Lire les fiches techniques de santé−sécurité (FTSS) et les instructions du fabricant concernant les métaux, les consommables, les
revêtements, les nettoyants et les dégraisseurs.
D Ne travailler dans un espace clos que s’il est bien ventilé ou porter un
respirateur à adduction d’air. Demander toujours à un surveillant dûment formé de se tenir à proximité. Des fumées et des gaz de soudage
peuvent se substituer à l’air, abaisser la teneur en oxygène et causer
des lésions ou des accidents mortels. S’assurer que l’air est respirable.
D Ne pas souder à proximité d’opérations de dégraissage, de nettoyage
ou de pulvérisation. La chaleur et les rayons de l’arc peuvent réagir en
présence de vapeurs et former des gaz hautement toxiques et irritants.
D Ne pas souder de métaux munis d’un revêtement, tels que la tôle
d’acier galvanisée, plombée ou cadmiée, à moins que le revêtement
n’ait été enlevé dans la zone de soudage, que l’endroit soit bien ventilé, et si nécessaire, porter un respirateur à adduction d’air. Les
revêtements et tous les métaux renfermant ces éléments peuvent dégager des fumées toxiques lorsqu’on les soude.
Revenez à la table des matières
OM-1500-15 Page 5
LES RAYONS DE L’ARC peuvent causer des brûlures oculaires et cutanées.
Le rayonnement de l’arc génère des rayons visibles et
invisibles intenses (ultraviolets et infrarouges) susceptibles de causer des brûlures oculaires et cutanées.
Des étincelles sont projetées pendant le soudage.
D Porter un masque de soudage muni d’un filtre de la nuance adéquate
pour se protéger le visage et les yeux pendant le soudage ou pour regarder (voir les normes de sécurité ANSI Z49.1 et Z87.1).
D Porter des lunettes de sécurité à écrans latéraux sous le masque.
D Utiliser des écrans ou des barrières pour protéger les tiers de l’éclat
éblouissant ou aveuglant de l’arc ; leur demander de ne pas regarder
l’arc.
D Porter des vêtements de protection en matière durable et ignifuge
(cuir ou laine) et des chaussures de sécurité.
LES ACCUMULATIONS DE GAZ peuvent causer des blessures ou même
la mort.
D
D
Couper l’alimentation en gaz protecteur en cas de
non utilisation.
Veiller toujours à bien ventiler les espaces confinés ou porter un respirateur à adduction d’air agréé.
LES PIÈCES CHAUDES peuvent causer des brûlures graves.
D Ne pas toucher les pièces chaudes à main nue.
D Prévoir une période de refroidissement avant
d’utiliser le pistolet ou la torche.
LE SOUDAGE peut causer un incendie ou une explosion.
LES CHAMPS MAGNÉTIQUES peuvent
perturber le fonctionnement des stimulateurs cardiaques.
Le soudage effectué sur des récipients fermés tels que
des réservoirs, des fûts ou des conduites peut causer
leur éclatement. Des étincelles peuvent être projetées
de l’arc de soudure. La projection d’étincelles, les
pièces chaudes et les équipements chauds peuvent causer des
incendies et des brûlures. Le contact accidentel de l’électrode avec tout
objet métallique peut causer des étincelles, une explosion, un surchauffement ou un incendie. Avant de commencer le soudage, vérifier et
s’assurer que l’endroit ne présente pas de danger.
D Se protéger et protéger les tiers de la projection d’étincelles et de métal chaud.
D Ne pas souder à un endroit où des étincelles peuvent tomber sur des
substances inflammables.
D Placer toutes les substances inflammables à une distance de 10,7 m
de l’arc de soudage. En cas d’impossibilité, les recouvrir soigneusement avec des protections agréées.
D Des étincelles et des matières en fusion peuvent facilement passer
même par des fissures et des ouvertures de petites dimensions.
D Surveiller tout déclenchement d’incendie et tenir un extincteur à proximité.
D Le soudage effectué sur un plafond, un plancher, une paroi ou une
cloison peut déclencher un incendie de l’autre côté.
D Ne pas souder des récipients fermés tels que des réservoirs, des fûts
ou des conduites, à moins qu’ils n’aient été préparés conformément à
l’AWS F4.1 (voir les normes de sécurité).
D Brancher le câble sur la pièce le plus près possible de la zone de soudage pour éviter que le courant ne circule sur une longue distance, par
des chemins inconnus, et ne cause des risques d’électrocution et d’incendie.
D Ne pas utiliser le poste de soudage pour dégeler des conduites gelées.
D En cas de non utilisation, enlever la baguette d’électrode du porte−
électrode ou couper le fil au raz du tube−contact.
D Porter des vêtements de protection exempts d’huile tels que des
gants en cuir, une chemise en tissu épais, des pantalons sans revers,
des chaussures montantes et un masque.
D Avant de souder, retirer tout produit combustible de ses poches, tel
qu’un briquet au butane ou des allumettes.
LES PARTICULES PROJETÉES peuvent blesser les yeux.
D Le soudage, le burinage, le passage de la pièce à
la brosse métallique et le meulage provoquent
l’émission d’étincelles et de particules métalliques. Pendant leur refroidissement, les soudures risquent de projeter du
laitier.
D
Porter des lunettes de sécurité à écrans latéraux agréés, même sous le
masque de soudage.
OM-1500-15 Page 6
D
D
Les personnes qui portent un stimulateur cardiaque
doivent se tenir à distance.
Ils doivent consulter leur médecin avant de s’approcher d’un lieu où on exécute des opérations de soudage à l’arc, de gougeage ou de soudage par points.
LE BRUIT peut affecter l’ouïe.
Le bruit de certains processus et équipements peut
affecter l’ouïe.
D
Porter des protecteurs d’oreille agréés si le niveau
sonore est trop élevé.
Les BOUTEILLES
peuvent exploser.
endommagées
Les bouteilles de gaz protecteur contiennent du gaz
sous haute pression. Toute bouteille endommagée
peut exploser. Comme les bouteilles de gaz font
normalement partie du procédé de soudage, les
manipuler avec précaution.
D Protéger les bouteilles de gaz comprimé de la chaleur excessive, des
chocs mécaniques, du laitier, des flammes nues, des étincelles et des
arcs.
D Placer les bouteilles debout en les fixant dans un support stationnaire
ou dans un porte−bouteilles pour les empêcher de tomber ou de se
renverser.
D Tenir les bouteilles éloignées des circuits de soudage ou autres circuits électriques.
D Ne jamais poser une torche de soudage sur une bouteille de gaz.
D Ne jamais mettre une électrode de soudage en contact avec une bouteille de gaz.
D Ne jamais souder une bouteille contenant du gaz sous pression − elle
risquerait d’exploser.
D N’utiliser que les bouteilles de gaz protecteur, régulateurs, tuyaux et
raccords adéquats pour l’application envisagée ; les maintenir en bon
état, ainsi que les pièces connexes.
D Détourner la tête lorsqu’on ouvre la soupape d’une bouteille.
D Laisser le capuchon protecteur sur la soupape, sauf en cas d’utilisation ou de branchement de la bouteille
D Lire et suivre les instructions concernant les bouteilles de gaz comprimé, les équipements associés et les publications P−1 de la CGA,
mentionnées dans les normes de sécurité.
Revenez à la table des matières
2-3. Autres symboles relatifs à l’installation, au fonctionnement et à l’entretien de
l’appareil.
Risque D’INCENDIE OU D’EXPLOSION
LES ORGANES MOBILES peuvent
causer des blessures.
D Ne pas placer l’appareil sur une surface inflammable, ni au−dessus ou à proximité d’elle.
D Se tenir à l’écart des organes mobiles comme les
ventilateurs.
D Maintenir fermés et bien fixés les portes,
panneaux, recouvrements et dispositifs de
protection.
D Ne pas installer l’appareil à proximité de produits inflammables.
D Ne pas surcharger l’installation électrique − s’assurer que l’alimentation est correctement dimensionnée et protégée avant de mettre
l’appareil en service.
LE RAYONNEMENT HAUTE FRÉQUENCE (H. F.) risque de causer des
interférences.
LA CHUTE DE L’APPAREIL peut
blesser.
D N’utiliser que l’anneau de levage pour lever l’appareil. NE PAS utiliser le chariot, les bouteilles de
gaz ou tout autre accessoire.
D Utiliser un engin de capacité adéquate pour lever
l’appareil.
D Si on utilise un chariot élévateur pour déplacer l’unité, s’assurer que
les fourches sont suffisamment longues pour dépasser du côté opposé de l’appareil.
L’EMPLOI EXCESSIF peut FAIRE
SURCHAUFFER L’ÉQUIPEMENT.
D Prévoir une période de refroidissement ; respecter le cycle opératoire nominal.
D Réduire le courant ou le cycle opératoire avant de
reprendre le soudage.
D Le rayonnement haute fréquence peut causer
des interférences avec les équipements de radionavigation et de communication, les services de
sécurité et les ordinateurs.
D Ne demander qu’à des personnes qualifiées familiarisées avec les
équipements électroniques de faire fonctionner l’installation.
D L’utilisateur est tenu de faire corriger rapidement par un électricien
qualifié les interférences causées par l’installation.
D Si la Federal Communications Commission signale des interférences, arrêter immédiatement l’appareil.
D Faire régulièrement contrôler et entretenir l’installation.
D Maintenir soigneusement fermés les panneaux et les portes des sources de haute fréquence, maintenir le jeu d’éclatement au réglage
adéquat et utiliser une terre et un blindage pour réduire les interférences éventuelles.
LE SOUDAGE À L’ARC peut causer
des interférences.
D Ne pas obstruer les orifices ou filtrer l’alimentation en air du poste.
D L’énergie électromagnétique peut causer des
interférences avec l’équipement électronique
sensible tel que les ordinateurs et l’équipement
commandé par ordinateur tel que les robots.
LES CHARGES ÉLECTROSTATIQUES peuvent endommager les circuits imprimés.
D Mettre un bracelet antistatique AVANT de manipuler des cartes ou des pièces.
D Utiliser des pochettes et des boîtes antistatiques
pour stocker, déplacer ou expédier des cartes de
circuits imprimés.
LES PIÈCES MOBILES peuvent causer des blessures.
D Se tenir à l’écart des pièces mobiles.
D Se tenir à l’écart des points de coincement tels
que les dévidoirs.
D Veiller à ce que tout l’équipement de la zone de soudage soit compatible au point de vue électromagnétique.
D Pour réduire la possibilité d’interférence, maintenir les câbles de soudage aussi courts que possible, les grouper, et les poser aussi bas
que possible (par ex. : à terre).
D Veiller à souder à une distance de 100 mètres de tout équipement
électronique sensible.
D Veiller à ce que le poste de soudage soit posé et mis à la terre conformément au présent manuel.
D En cas d’interférences après exécution des directives précédentes, il
incombe à l’utilisateur de prendre des mesures supplémentaires telles que le déplacement du poste, l’utilisation de câbles blindés,
l’utilisation de filtres de ligne ou la pose de protecteurs dans la zone de
travail.
LES FILS DE SOUDAGE peuvent causer des blessures.
D Ne pas appuyer sur la gâchette avant d’en avoir
reçu l’instruction.
D Ne pas diriger le pistolet vers soi, vers d’autres
personnes ou vers toute pièce mécanique en engageant le fil de soudage.
Revenez à la table des matières
LES CHAMPS MAGNÉTIQUES peuvent
affecter les stimulateurs cardiaques.
D Porteurs de stimulateur cardiaque, restez à distance.
D Les porteurs d’un stimulateur cardiaque doivent
d’abord consulter leur médecin avant de s’approcher des opérations de soudage à l’arc, de gougeage ou de soudage par points.
OM-1500-15 Page 7
2-4. Principales normes de sécurité
Safety in Welding, Cutting, and Allied Processes, norme ANSI Z49.1,
de l’American Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126
(téléphone : (305) 443−9353, site Web : www.aws.org).
Rexdale, Rexdale (Ontario) Canada M9W 1R3 (téléphone : (800)
463−6727 ou à Toronto : (416) 747−4044, site Web : www.csa−international.org).
Recommended Safe Practices for the Preparation for Welding and Cutting of Containers and Piping, norme American Welding Society AWS
F4.1, de l’American Welding Society, 550 N.W. LeJeune Rd, Miami, FL
33126 (téléphone : (305) 443−9353, site Web : www.aws.org).
Practice For Occupational And Educational Eye And Face Protection,
norme ANSI Z87.1, de l’American National Standards Institute, 11 West
42nd Street, New York, NY 10036−8002 (téléphone : (212) 642−4900,
site Web : www.ansi.org).
National Electrical Code, norme NFPA 70, de la National Fire Protection
Association, P.O. Box 9101, 1 Battery March Park, Quincy, MA
02269−9101 (téléphone : (617) 770−3000, sites Web : www.nfpa.org et
www.sparky.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, norme NFPA 51B, de la National Fire Protection Association,
P.O. Box 9101, 1 Battery March Park, Quincy, MA 02269−9101 (téléphone : (617) 770−3000, site Web : www.nfpa.org et www.sparky.org).
Safe Handling of Compressed Gases in Cylinders, brochure CGA P−1,
de la Compressed Gas Association, 1735 Jefferson Davis Highway,
Suite 1004, Arlington, VA 22202−4102 (téléphone : (703) 412−0900,
site Web : www.cganet.com).
Code for Safety in Welding and Cutting, norme CSA W117.2, de la Canadian Standards Association, Standards Sales, 178 boulevard
OSHA, Occupational Safety and Health Standards for General Industry, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,
and Part 1926, Subpart J, de l’U.S. Government Printing Office, Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250 (il y a
10 bureaux régionaux − Téléphone pour la Région 5, Chicago : (312)
353−2220, site Web : www.osha.gov).
2-5. Information sur les champs électromagnétiques
Données sur le soudage électrique et les effets des champs magnétiques basse fréquence sur l’organisme
En parcourant les câbles de soudage, le courant crée des champs électromagnétiques. Les effets potentiels de tels champs restent
préoccupants. Cependant, après avoir examiné plus de 500 études qui
ont été faites pendant une période de recherche de 17 ans, un comité
de spécialistes du National Research Council a conclu : « L’accumulation de preuves n’a pas démontré que l’exposition aux champs
magnétiques et aux champs électriques à haute fréquence constitue un
risque pour la santé humaine ». Toutefois, les études et l’examen des
preuves se poursuivent. En attendant les conclusions finales de la recherche, il serait souhaitable de réduire l’exposition aux champs
électromagnétiques pendant le soudage ou le coupage.
OM-1500-15 Page 8
Afin de réduire les champs électromagnétiques en milieu de travail, respecter les consignes suivantes :
1. Garder les câbles ensemble en les torsadant ou en les fixant avec du
ruban adhésif.
2. Mettre tous les câbles du côté opposé à l’opérateur.
3. Ne pas s’enrouler les câbles autour du corps.
4. Garder le poste de soudage et les câbles le plus loin possible de soi.
5. Placer la pince de masse le plus près possible de la zone de soudage.
Consignes relatives aux stimulateurs cardiaques :
Les personnes qui portent un stimulateur cardiaque doivent avant tout
consulter leur médecin. Si ce dernier les déclare aptes, il leur est recommandé de respecter les consignes ci-dessus.
Revenez à la table des matières
SECTION 3 − DEFINITIONS
3-1. Warning Label Definitions
Warning! Watch Out! There are
possible hazards as shown by the
symbols.
Drive rolls can injure fingers
Welding wire and drive parts are at
welding voltage during operation −
keep hands and metal objects
clear.
1
1.1
2
2.1
3
3.1
4
4.1
1.2
2.2
2.3
3.2
+
5
1.3
3.3
+
+
6
+
S-178 936
Return To Table Of Contents
1 Electric shock can kill.
1.1 Wear dry insulating gloves.
Do not touch electrode with
bare hand. Do not wear wet or
damaged gloves.
1.2 Protect yourself from electric
shock by insulating yourself
from work and ground.
1.3 Disconnect input plug or
power before working on
machine.
2 Breathing welding fumes can
be hazardous to your health.
2.1 Keep your head out of the
fumes.
2.2 Use forced ventilation or local
exhaust to remove the fumes.
2.3 Use ventilating fan to remove
fumes.
3 Welding sparks can cause
explosion or fire.
3.1 Keep flammables away from
welding. Don’t weld near
flammables.
3.2 Welding sparks can cause
fires. Have a fire extinguisher
nearby and have a watch
person ready to use it.
3.3 Do not weld on drums or any
closed containers.
4 Arc rays can burn eyes and
injure skin.
4.1 Wear hat and safety glasses.
Use ear protection and button
shirt collar. Use welding
helmet with correct shade of
filter. Wear complete body
protection.
5 Become trained and read the
instructions before working on
the machine or welding.
6 Do not remove or paint over
(cover) the label.
OM-1500-15 Page 9
3-2. Manufacturer’s Rating Label For CE Products
For label location
see Section 5-1.
S/N:
U1 24 V
=I1= 10.0 A
50/60 Hz
IP 23
1
U2 100 V I2= 500 A
X 100 %
= MILLER ELECTRIC MFG. CO., APPLETON, WI USA
ST-178 794-A
3-3. Symbols And Definitions
NOTE
X
Some symbols are found only on CE products.
Duty Cycle
Wire Feed
Percent
Input
Cold Jog (Inch) Towards Workpiece
Purge By Gas
Fast
Constant Current
Circuit Breaker
Constant Voltage
Slow
Trigger Hold Off
Trigger Hold On
Rated Welding
Current
Increase
U1
Primary Voltage
Amperes
V
IP
Input
Read Instructions
I1
A
Output
I2
U2
Conventional Load
Voltage
Volts
Degree Of Protection
Hz
Hertz
Primary Current
SECTION 4 − INSTALLATION
4-1. Specifications
Type of
Input
Power
Welding
Power
Source
Type
24 Volts AC
Single Phase
10 Amperes
50/60 Hz
Constant
Voltage (CV)
DC With
14-Pin And
Contactor
Control
OM-1500-15 Page 10
Wire Feed
Speed
Range
50 to 700 ipm
(1.3 To 17.8
mpm)
Wire
Diameter
Range
Input
Welding
Circuit
Rating
.023 To 5/64 in
(0.6 To 2 mm)
100 Volts,
500
Amperes,
100%
Duty Cycle
IP
Rating
Return To Table Of Contents
23
Max. Wire
Spool
Capacity
30 lb (13.6
kg),
12 in (304
mm)
Overall
Dimensions
Weight
Length: 20 in
(508 mm)
Width: 8 in
(203 mm)
Height: 15-1/2 in
(394 mm)
25.5 lb
(11.6 kg)
4-2. 14-Pin Plug Information
Pin*
J
I
H
K
A
B
L C
M D
E
N
G
F
Pin Information
A
24 volts ac with respect to socket G.
B
Contact closure to A completes 24 volts ac contactor control circuit.
G
Circuit common for 24 volts AC circuit.
C
+10 volts dc input from power source to wire feeder with respect to socket D.
D
Remote control circuit common.
E
0 to +10 volts dc output signal from wire feeder to power source with respect to socket D.
H
Voltage feedback; 0 to +10 volts dc, 1 volt per 10 arc volts.
F
Current feedback; 0 to +10 volts dc, 1 volt per 100 amperes.
*The remaining pins are not used.
4-3. Gun Recommendation Table
Process
Gun
GMAW − Hard or Cored Wires
Roughneck C-Series Guns: 300, 400, 500, And 600 Amp.
FCAW − Self-Shielding Wires
FC-1260 Or FC-1150
4-4. Equipment Connection Diagram
1
Constant Voltage (CV)
Welding Power Source
Supplying 24 VAC To Feeder
Use optional PSA-2 adapter for
power sources having only 115
VAC supply.
1
2
3
4
5
Negative (−) Weld Cable
Positive (+) Weld Cable
Workpiece
Interconnecting Cord
(Customer Supplied)
6 14-Pin Plug And Cord
7 Wire Feeder
8 Gun
9 Gun Trigger Receptacle
10 Gas Hose
11 Gas Cylinder
11
2
3
10
9
5
4
6
8
7
803 300-A
Return To Table Of Contents
OM-1500-15 Page 11
4-5. Installing And Aligning Wire Guide And Drive Rolls
Installing Wire Guide And Drive
Rolls:
1
2
Drive Roll Nut
Drive Roll Carrier
Turn nut one click until lobes of nut
line up with lobes of drive roll carrier.
3
Drive Roll
Slide drive roll onto drive roll carrier.
Turn nut one click.
Repeat procedure for top drive roll.
4
5
Inlet Wire Guide Screw
Inlet Wire Guide
Loosen securing screw. Install inlet
guide so inlet guide screw is
centered in groove in guide, or so tip
is as close to drive rolls as possible
without touching. Tighten screw.
Installing Wire Guide
And Drive Rolls
Aligning Wire Guide And Drive
Rolls:
View is from top of drive rolls looking down with pressure assembly
open.
5
6
7
8
9
10
4
3
Drive Roll Securing Nut
Drive Roll
Wire Guide
Welding Wire
Drive Gear
Turn screw in or out until drive roll
groove lines up with wire guide.
1
Close pressure roll assembly.
Only bottom drive roll alignment is
adjustable. Turn adjustment screw
in or out until groove in drive roll
lines up with wire guide as shown.
2
Cleaning Drive Rolls:
Aligning Wire Guide And Drive Rolls
Correct
8
Remove drive rolls, and clean
grooves using a wire brush.
Incorrect
9
7
Tools Needed:
6
3/16 in
10
3/8 in
803 285
OM-1500-15 Page 12
Return To Table Of Contents
4-6. Connecting Welding Gun
1
2
3
Gun Securing Knob
Gun Block
Gun Outlet Wire Guide
Loosen knob, insert gun end into
block. Position outlet wire guide as
close as possible to drive rolls without touching. Tighten knob.
2
1
4
5
Gun Trigger Plug
Gun Trigger Receptacle
Internal Side View
3
5
4
803 301-A
4-7. Connecting Shielding Gas
1
3
4
Rear View
2
3
4
5
Gas Hose With 5/8-18
Right-hand Thread Fittings
(Customer Supplied)
Shielding Gas Cylinder
Valve
Flowmeter
14-Pin Plug
Close valve on cylinder when finished welding.
2
5
Tools Needed:
1
5/8 in
803 302
Return To Table Of Contents
OM-1500-15 Page 13
4-8. Connecting Weld Cable
1
Internal Side View
2
3
From Wire Feeder
User-Suppled Weld Cable
Follow wire manufacturer’s recommendations for weld cable polarity.
User-Suppled Male Connector
User-Suppled Female
Connector
Push female connector over male
connector, and turn 1/4 turn clockwise.
2
1
3
Ref. 132 808-F / Ref. 802 706
4-9. Installing And Threading Welding Wire
Hold wire tightly to keep it
from unraveling.
Installing Wire And Adjusting
Hub Tension:
1
2
Retaining Nut
Hub Tension Adjustment
Screw
Remove retaining ring, and install
spool so hub pin fits spool hole. Reinstall retaining nut.
Adjust tension nut so only a slight
force is needed to turn spool.
Threading Welding Wire:
3
Pressure Assembly
Adjustment Knob
Lay gun cable out straight.
Open pressure assembly, hold wire
tightly, and cut off end. Push wire
through guides into gun.
3
1
Close and tighten pressure assembly. Press gun trigger until wire
comes out gun.
Feed wire against wooden surface,
and tighten knob so wire does not
slip.
2
Cut off wire, and close door.
6 in
(150 mm)
Pull and hold wire; cut off end.
Tools Needed:
Tighten
Clockwise
9/16 in
WOOD
803 289
OM-1500-15 Page 14
Return To Table Of Contents
SECTION 5 − OPERATION
5-1. Controls
1
2
1
2
Purge Switch
Power Control Switch
Press switch to momentarily energize gas solenoid and purge air
from gun, and to adjust shielding
gas regulator.
OFF
ON
3
4
Voltage Control (Optional)
Wire Speed Control
Use control to adjust wire speed
within range selected by switch.
5
Jog Switch
Use Jog position to momentarily
feed welding wire at speed set on
Wire Speed control without energizing welding circuit or shielding
gas valve.
Close and latch door.
4
3
Front Panel
5
JOG
Internal Control Panel
Internal Side View
209 964 / Ref. 803 304-A / Ref. 209 967-B
Return To Table Of Contents
OM-1500-15 Page 15
5-2. Controls For Meter (Optional)
1
2
Depress the upper part of the switch
(turns trigger hold On) to weld without
holding gun trigger throughout the
weld cycle.
2
OFF
3
Power Control Switch
Trigger Hold Switch
1
ON
To start weld, press and release gun
trigger. To end weld, press and release gun trigger.
Depress the lower part of the trigger
hold switch to turn trigger hold Off.
4
3
Purge Switch
Press switch to momentarily energize
gas solenoid and purge air from gun,
and to adjust shielding gas regulator.
5
4
5
7
6
Meter Display
Volts, Wire Feed Speed Or
Amps Select Switch
. Meter
is factory set to display
voltage and wirefeed speed. To
display voltage and amps refer to
Section 5-4 for DIP switch settings.
6
7
Voltage Control
Wire Speed Control
Use control to adjust wire speed within range selected by switch.
Close and latch door.
Front P anel
Ref. 210 922-B / 209 964 / Ref. 803 304-A
5-3. Controls For CE Models
1
2
Depress the upper part of the switch
(turns trigger hold On) to weld without
holding gun trigger throughout the
weld cycle.
2
OFF
3
Power Control Switch
Trigger Hold Switch
1
ON
To start weld, press and release gun
trigger. To end weld, press and release gun trigger.
Depress the lower part of the trigger
hold switch to turn trigger hold Off.
4
3
Purge Switch
Press switch to momentarily energize
gas solenoid and purge air from gun,
and to adjust shielding gas regulator.
5
4
5
7
6
Meter Display
Volts, Wire Feed Speed Or
Amps Select Switch
. Meter
is factory set to display
voltage and wirefeed speed. To
display voltage and amps refer to
Section 5-4 for DIP switch settings.
6
7
Voltage Control
Wire Speed Control
Use control to adjust wire speed within range selected by switch.
Front P anel
Close and latch door.
Ref. 213 191-A / 209 964 / Ref. 803 304-A
OM-1500-15 Page 16
Return To Table Of Contents
5-4. Setting Digital Meter Board PC4 DIP Switches
1
2
3
1
2
Meter DIP switches are
factory set to display wirefeed
speed in inches per minute, voltage
and amperage thru 14 pin feedback. Meter hold feature is factory
set to off position.
3
Front Meter Panel
S1 DIP Switch
S2 DIP Switch
If the DIP switches are set to a Meter
Hold (ON) position, the meter value
will hold 5 seconds after gun is triggered. The meter value will continue
to hold for 8 seconds after trigger is
released or until gun is re-triggered.
. When using power sources
without 14 pin voltage/current
feedback − optional remote
voltage/current kit 195 194 is
required.
Indicates this DIP switch setting has
no effect on this function.
Wire Feed Speed Display
Inches Per Minute
Meters Per Minute
S1
S2
S1
S2
S2
Voltage
Sense Lead
(Optional)
14 Pin
Voltage
Feedback
S2
14 Pin
Voltage
Feedback
Voltage
Sense Lead
(Optional)
Meter Hold
(ON)
(OFF)
S1
S1
Amps Display
S2
S2
14 Pin
Current
Feedback
Current Sensor
(Optional)
803 141/ Ref. 803 124
Return To Table Of Contents
OM-1500-15 Page 17
5-5. Gun Consumables Information
200 007-B
Notes
OM-1500-15 Page 18
Return To Table Of Contents
SECTION 6 − MAINTENANCE & TROUBLESHOOTING
6-1. Routine Maintenance
. Maintain more often
Y Disconnect power
before maintaining.
during severe conditions.
3 Months
Replace
Damaged Or
Unreadable
Labels
Replace Damaged
Gas Hose
Repair Or Replace
Cracked Cables
And Cords
6 Months
Clean
Drive
Rolls
Blow Out Or
Vacuum Inside
6-2. Overload Protection And Thermostat Protection
Y Turn Off wire feeder and
welding power source. Stop
engine
on
welding
generator.
1
1
Circuit Breaker CB1
CB1 protects wire feeder from overload. Correct problem and reset
CB1.
Close and latch door.
CB1
Thermostat Protection
Unit has internal thermostat protection and will not feed wire if overheating occurs (see Section 6-3).
Internal Side View
Ref. 803 304
Return To Table Of Contents
OM-1500-15 Page 19
6-3. Troubleshooting
Trouble
Remedy
Wire does not feed, unit completely inop- Turn Power switch On.
erative.
Check 14−pin plug PLG2 connections.
Check input power.
Wire does not feed.
Check circuit breaker CB1. (see Section 6-2).
Check gun trigger connection at wire feeder. Check gun trigger leads and trigger switch. See gun Owner’s
Manual.
Have Factory Authorized Service Agent check drive motor and control board PC1.
Wire feeds erratically.
Readjust hub tension and drive roll pressure (see Section 4-9).
Use correct size drive roll (see Parts Listing).
Clean or replace dirty or worn drive roll (see Section 4-5).
Remove weld spatter around nozzle opening.
Replace contact tip or liner. See gun Owner’s Manual.
Have Factory Authorized Service Agent check drive motor and control board PC1.
Wire feeds when Jog switch is pressed Check gun trigger connection at wire feeder. Check gun trigger leads and trigger switch. See gun Owner’s
but not when gun trigger is pressed.
Manual.
Wire feeds as soon as power is applied. Check gun trigger. See gun Owner’s Manual.
Wire does not feed until trigger is Check for short between gun trigger leads and weld cable. Repair or replace gun trigger leads.
pressed but continues to feed after trigger is released.
Gas valve rattles loudly and wire feeds Check for short between gun trigger leads and weld cable. Repair or replace gun trigger leads.
slowly or erratically.
Gas does not flow; wire feeds.
OM-1500-15 Page 20
Check gas valve.
Return To Table Of Contents
SECTION 7 − ELECTRICAL DIAGRAMS
215 341-A
Figure 7-1. Circuit Diagram For Wire Feeder
Return To Table Of Contents
OM-1500-15 Page 21
SECTION 8 − PARTS LIST
1
H ardw are is common and
not available unless listed.
2
3
52
41
4
5
42
51
57
62
6
53
63 43
58
55
50
44
4
13
7
49
59
45
40
54
46
47
66
56
9
38
11
12
48
39
64
36
65
61
14
10
8
37
36
16
35
15
34
33
17
18
19
60
20
32
30
31
21
29
22
23
26
24
25
27
28
OM-1500-15 Page 22
Figure 8-1. Com plete Assembly
Return To Table Of Contents
803 373−D
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 8-1. Complete Assembly
. . 1 . . . . . . . . . . . . . . 209 450
. . 2 . . . . . . . . . . . . . . 172 919
. . 3 . . . . . . . . . . . . . . 172 918
. . 4 . . . . . . . . . . . . . . 201 309
. . 5 . . . . . . . . . . . . . . 209 451
. . 6 . . . . . . . . . . . . . . 058 424
. . 7 . . . . . . . . . . . . . . 208 053
. . 8 . . . . . . . . . . . . . . 209 452
. . 9 . . . . . . . . . . . . . . 605 227
. . 10 . . . . . . . . . . . . . 207 680
. . 11 . . . . . . . . . . . . . 139 041
. . . . . . . . . . . . . . . . . . . 214 860
. . 12 . . . . . . . . . . . . . 210 364
. . . . . . . . . . . . . . . . . . . 079 739
. . . . . . . . . . . . . . . . . . . 600 797
. . . . . . . . . PLG9 . . . 141 162
. . . . . . . . . . . . . . . . . . . . 115 093
. . . . . . . . . . . . . . . . . . . 131 204
. . 13 . . . . . . . . . . . . . 097 132
. . 14 . . . . GS1 . . . . 125 785
. . 15 . . . . S3 . . . . . 200 640
. . 16 . . . . . . . . . . . . . 147 195
. . 17 . . . . . . . . . . . . . 210 141
. . 18 . . . . . . . . . . . . . 208 076
. . 19 . . . . CB1 . . . . 083 432
. . 20 . . . . . . . . . . . . . 214 004
. . . . . . . . . . . . . . . . . . . 217 749
. . 21 . . . . . . . . . . . . . 126 415
. . 22 . . . . . . . . . . . . . 126 416
. . 23 . . R1, R50 . . 073 562
. . 24 . . . . . . . . . . . . . 209 487
. . 25 . . . . . . . . . . . . . 209 966
. . 25 . . . . . . . . . . . . . 213 190
. . 26 . . . . . . . . . . . . . 193 920
. . 27 . . . . S2 . . . . . 200 640
. . 28 . . . . S1 . . . . . . 111 997
. . 29 . . . . . . . . . . . . . 213 995
. . . . . . . . . . . . . . . . . . . 049 455
. . . . . . . . . . RC2 . . . . 048 834
. . . . . . . . . . . . . . . . . . . 080 328
. . . . . . . . . PLG6 . . . . 115 094
. . 30 . . . . . . . . . . . . . 070 654
. . 31 . . . . . . . . . . . . . 214 006
. . 32 . . . . . . . . . . . . . 214 010
. . 33 . . . . . . . . . . . . . 081 895
. . 34 . . . . . . . . . . . . . 215 364
. . 35 . . . . . . . . . . . . . 208 000
. . 36 . . . . . . . . . . . . . 098 615
. . 37 . . . . . . . . . . . . . 212 587
. . 38 . . . . M1 . . . . 208 001
. . 39 . . . . . . . . . . . . . 144 172
. . 40 . . . . . . . . . . . . . 207 679
. . 41 . . . . . . . . . . . . . 124 778
. . 42 . . . . . . . . . . . . . 172 075
. . 43 . . . . . . . . . . . . . 010 224
. . 44 . . . . . . . . . . . . . 172 076
. . 45 . . . . . . . . . . . . . 089 562
. . Nut, Hub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Knob, Brake Adjust . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Washer, Anti−turn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . Hub, Spool (Mod) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Washer, Fibre (Brake) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Shroud, Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Support, Spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Nut, 750−14 Knurled1.68dia .41h Nyl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Insulator, Strain Relief/Gas Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Bushing, Strain Relief .481/.617 Id X1.115 Mtg Hole (Includes) . . . . . . . . 2
. . . . Nut, Ln Pg21 1.26Hex .14H Nickel Plated Brass . . . . . . . . . . . . . . . . . . . 1
. . Cable, Power 17 In (Includes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Conn, Circ Cpc Clamp Str Rlf Size 17−20 .703od . . . . . . . . . . . . . . . . . . 1
. . . . Cable, Port No 16 8/C Type So Rb Jkt . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4 ft
. . . . Housing Plug+Pins, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . As Rqd
. . . . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . As Rqd
. . . . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . As Rqd
. . Stand−Off, No 6−32 X .375 Lg .250 Hex Brs M&f . . . . . . . . . . . . . . . . . . . . 1
. . Valve, 24VAC 2Way Custom Port 1/8 Orf W/Frict . . . . . . . . . . . . . . . . . . . . 1
. . Switch Assy, Elect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Nut, 375−27 .54Hex .25h Nyl Flange .62D . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Nameplate, Inner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Panel, Inner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Circuit Breaker, Man Reset 1P 10A 250VAC Frict . . . . . . . . . . . . . . . . . . . . 1
. . Case, Control Feeder Plastic (Includes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Spacer, Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Clamp, Saddle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Handle, Molded Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Pot, Cp Std Slot 1t 2. W 10k Linear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . Panel, Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Nameplate, Miller SuitCase 12RC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Nameplate, Miller SuitCase 12RC W/Meters, Triggerhold (CE) . . . . . . . . 1
. . Knob, Pointer .840 Dia X .250 Id W/One Set Screw . . . . . . . . . . . . . . . . . . 2
. . Switch, Rocker Dpdt 8A 125VAC On−None−On Black . . . . . . . . . . . . . . . . 1
. . Switch, Rocker Spst 10A 250VAC On−Off Visi Red Rock . . . . . . . . . . . . . 1
. . Cable, Trigger 20 In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Cable, Port No 18 2/C Type sjo nprn Jkt . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Conn, Circ Cpc Clamp Str Rlf Size 11 .329OD . . . . . . . . . . . . . . . . . . . . . 1
. . . . Rcpt W/Skts, Free Hanging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Bushing, Strain Relief .300 Id X .550 Mtg Hole . . . . . . . . . . . . . . . . . . . . . . 1
. . Panel, Front Lower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Panel, Front Lower Backing Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Nut, 010−32 Rubber .75Dia .81l Insert In .38Hole . . . . . . . . . . . . . . . . . . . . 5
. . Chassis, Control Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Washer, Shldr.260ID 0.630ODX.125T .327ODX.062T Nyl . . . . . . . . . . . . . 4
. . Hose, Sae .187 Id X .410 Od X 20.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Insulator, Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Motor, Right Angle 24VDC 145 RPM 37.5 Ratio . . . . . . . . . . . . . . . . . . . . . 1
. . Ftg, Hose Brs Barbed M 3/16 Tbg X .250−20 . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Insert, Corner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Knob, T 2.000 Bar W/.312−18 Stud 1.000 Lg Plstc . . . . . . . . . . . . . . . . . . . 1
. . Carrier, Drive Roll W/Components 24 Pitch . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Pin, Spring Cs .187 X 1.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Carrier, Drive Roll W/Components Keyed 24 Pitch . . . . . . . . . . . . . . . . . . . 1
. . Fastener, Pinned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Return To Table Of Contents
OM-1500-15 Page 23
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 8-1. Complete Assembly (Continued)
. . 46 . . . . . . . . . . . . . 085 244
. . 47 . . . . . . . . . . . . . 085 243
. . 48 . . . . . . . . . . . . . 166 071
. . 49 . . . . . . . . . . . . . 209 402
. . 50 . . . . . . . . . . . . . 025 248
. . 51 . . . . . . . . . . . . . 208 002
. . 52 . . . . . . . . . . . . . 207 940
. . 53 . . . . . . . . . . . . . 210 850
. . . . . . . . . . . . . . . . . . . 600 322
. . 54 . . . . . . . . . . . . . 097 132
. . 55 . . . . PC1 . . . . 212 193
. . 56 . . . . . . . . . . . . . 207 677
. . 57 . . . . . . . . . . . . . 210 133
. . 58 . . . . C1 . . . . . 177 360
. . 59 . . . . . . . . . . . . . 207 678
. . 60 . . . . . . . . . . . . . 134 327
. . 60 . . . . . . . . . . . . . 178 936
. . 61 . . . . . . . . . . . . . 196 956
. . . . . . . . . PC30 . . ♦211 444
. . . . . . . . . . . . . . . . . . ♦097 132
. . . . . . . . . . . . . . . . . . ♦098 691
. . . . . . . . . . . . . . . . . . ♦211 883
. . . . . . . . . . PC4 . . . ♦210 768
. . . . . . . . . . . . . . . . . . ♦093 551
. . . . . . . . . . . . . . . . . . ♦209 963
. . . . . . . . . . S31 . . . ♦120 376
. . . . . . . . . . . . . . . . . . ♦133 644
. . 62 . . . . . . . . . . . . . 092 865
. . 63 . . . . . . . . . . . . . 079 625
. . 64 . . . . . . . . . . . . . 079 634
. . 65 . . . . . . . . . . . . . 151 828
. . 66 . . . . . . . . . . . . . . 211 989
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
Washer, Cupped .328IDX .812ODX16GAX.125 Lip . . . . . . . . . . . . . . . . . . 1
Knob, Adjust Tension 1.250 Dia X .312−18 Thrd Stl . . . . . . . . . . . . . . . . . . 1
Lever, Mtg Pressure Gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Thermostat, NC Open 140C Close 110C Snap Action . . . . . . . . . . . . . . . . 1
Stand-Off, Insul .250−20 X 1.250 Lg X .437 THD . . . . . . . . . . . . . . . . . . . . 1
Bus Bar, Interconnecting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Grommet, Bus Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Cable, Weld 20 In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Cable, Weld Cop Strd No 2/0 Epdm Jkt (Order by Ft) . . . . . . . . . . . . . . As Rqd
Stand−Off, No 6−32 X .375 Lg .250 Hex Brs M&f . . . . . . . . . . . . . . . . . . . . 4
Circuit Card Assy, Motor Speed Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Insulator, PC Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Bracket, Capacitor Support SC12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Capacitor, Elctlt 20000 Uf 45 VDC Can 1.40 Dia . . . . . . . . . . . . . . . . . . . . . 1
Insulator, Capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Label, Warning General Precautionary Static And Wire Feed . . . . . . . . . . 3
Label, Warning General Precautionary Wordless (CE) . . . . . . . . . . . . . . . . 3
Label, Warning Electric Shock And Pinch Wordless . . . . . . . . . . . . . . . . . . 1
Circuit Card Assy, Trigger Hold/Burnback (Trigger Hold Option) . . . . . . . . 1
Standoff, No 6-32 x .375 Lg (Trigger Hold Option) . . . . . . . . . . . . . . . . . . . . 1
Standoff, No 6-32 x .500 Lg (Trigger Hold Option) . . . . . . . . . . . . . . . . . . . . 1
Plug Assy, Trigger Hold (Trigger Hold Option) . . . . . . . . . . . . . . . . . . . . . . . 1
Circuit Card Assy, Meter (Meter Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Knob, Pointer (Meter Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Nameplate, Miller Suitcase 12 RC W/Meters,Triggerhold . . . . . . . . . . . . . . 1
Switch, Rocker Spdt 4A 250VAC On−None−On Spade Ter . . . . . . . . . . . . 1
Frame, Snap−in Switch Rocker Panel Mtg . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Key, Stl .1215/.1230 x .750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Washer, Wave .500idx0.750odx.015t Stl Lbs . . . . . . . . . . . . . . . . . . . . . . . . 2
Pin, Hinge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Pin, Cotter Hair .042 X .750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Fitting, W/Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. Meter and Trigger Hold feature optional in non-CE models, standard in CE models
♦ Optional
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-1500-15 Page 24
Return To Table Of Contents
Table 8-1. Drive Roll And Wire Guide Kits
NOTE
Base selection of drive rolls upon the following recommended usages:
1. V-Grooved rolls for hard wire.
2. U-Grooved rolls for soft and soft shelled cored wires.
3. U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types).
4. V-Knurled rolls for hard shelled cored wires.
5. Drive roll types may be mixed to suit particular requirements (example:
V-Knurled roll in combination with U-Grooved).
Wire Diameter
Fraction
Decimal
Metric
Kit No.
Drive Roll
Part No.
Type
Inlet
Wire Guide
.023/.025 in
.023/.025 in
0.6 mm
087 131
087 130
V-Grooved
056 192
.030 in
.030 in
0.8 mm
079 594
053 695
V-Grooved
056 192
.035 in
.035 in
0.9 mm
079 595
053 700
V-Grooved
056 192
.040 in
.040 in
1.0 mm
161 189
053 696
V-Grooved
056 192
.045 in
.045 in
1.2 mm
079 596
053 697
V-Grooved
056 193
.052 in
.052 in
1.3 mm
079 597
053 698
V-Grooved
056 193
1/16 in
.062 in
1.6 mm
079 598
053 699
V-Grooved
056 195
.035 in
.035 in
0.9 mm
044 749
072 000
U-Grooved
056 192
.045 in
.045 in
1.2 mm
079 599
053 701
U-Grooved
056 193
.052 in
.052 in
1.3 mm
079 600
053 702
U-Grooved
056 193
1/16 in
5/64 in
.062 in
.079 in
1.6 mm
2.0 mm
079 601
079 602
053 706
053 704
U-Grooved
U-Grooved
056 195
056 195
.035 in
.035 in
0.9 mm
079 606
132 958
V-Knurled
056 192
.045 in
.045 in
1.2 mm
079 607
132 957
V-Knurled
056 193
.052 in
.052 in
1.3 mm
079 608
132 956
V-Knurled
056 193
1/16 in
.062 in
1.6 mm
079 609
132 955
V-Knurled
056 195
.068-.072 in
.068-.072 in
1.8 mm
089 984
132 959
V-Knurled
056 195
5/64 in
.079 in
2.0 mm
079 610
132 960
V-Knurled
056 195
.045 in
.045 in
1.2 mm
083 318
083 489
U-Cogged
056 193
.052 in
.052 in
1.3 mm
083 317
083 490
U-Cogged
056 193
1/16 in
.062 in
1.6 mm
079 614
053 708
U-Cogged
056 195
5/64 in
.079 in
2.0 mm
079 615
053 710
U-Cogged
056 195
S-0157-C
Return To Table Of Contents
OM-1500-15 Page 25
Notes
Work like a Pro!
Pros weld and cut
safely. Read the
safety rules at
the beginning
of this manual.
OM-1500-15 Page 26
Return To Table Of Contents
Effective January 1, 2003
(Equipment with a serial number preface of “LC” or newer)
This limited warranty supersedes all previous Miller warranties and is exclusive with no other
guarantees or warranties expressed or implied.
Warranty Questions?
Call
1-800-4-A-MILLER
for your local
Miller distributor.
LIMITED WARRANTY − Subject to the terms and conditions
below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants
to its original retail purchaser that new Miller equipment sold
after the effective date of this limited warranty is free of defects
in material and workmanship at the time it is shipped by Miller.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS.
Your distributor also gives
you ...
Within the warranty periods listed below, Miller will repair or
replace any warranted parts or components that fail due to
such defects in material or workmanship. Miller must be
notified in writing within thirty (30) days of such defect or
failure, at which time Miller will provide instructions on the
warranty claim procedures to be followed.
Service
You always get the fast,
reliable response you
need. Most replacement
parts can be in your
hands in 24 hours.
Support
Need fast answers to the
tough welding questions?
Contact your distributor.
The expertise of the
distributor and Miller is
there to help you, every
step of the way.
Miller shall honor warranty claims on warranted equipment
listed below in the event of such a failure within the warranty
time periods. All warranty time periods start on the date that
the equipment was delivered to the original retail purchaser, or
one year after the equipment is sent to a North American
distributor or eighteen months after the equipment is sent to an
International distributor.
1.
5 Years Parts — 3 Years Labor
*
*
2.
3 Years — Parts and Labor
*
*
*
*
*
*
*
3.
Original main power rectifiers
Inverters (input and output rectifiers only)
Transformer/Rectifier Power Sources
Plasma Arc Cutting Power Sources
Semi-Automatic and Automatic Wire Feeders
Inverter Power Supplies
Intellitig
Maxstar 150
Engine Driven Welding Generators
(NOTE: Engines are warranted separately by
the engine manufacturer.)
1 Year — Parts and Labor Unless Specified
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
DS-2 Wire Feeder
Motor Driven Guns (w/exception of Spoolmate
Spoolguns)
Process Controllers
Positioners and Controllers
Automatic Motion Devices
RFCS Foot Controls
Induction Heating Power Sources
Water Coolant Systems
Flowgauge and Flowmeter Regulators (No Labor)
HF Units
Grids
Maxstar 85, 140
Spot Welders
Load Banks
Racks
Running Gear/Trailers
Plasma Cutting Torches (except APT & SAF
Models)
Field Options
(NOTE: Field options are covered under True
Blue for the remaining warranty period of the
product they are installed in, or for a minimum of
one year — whichever is greater.)
4.
6 Months — Batteries
5.
90 Days — Parts
*
MIG Guns/TIG Torches
*
*
*
*
*
*
*
Induction Heating Coils and Blankets
APT & SAF Model Plasma Cutting Torches
Remote Controls
Accessory Kits
Replacement Parts (No labor)
Spoolmate Spoolguns
Canvas Covers
Miller’s True Blue Limited Warranty shall not apply to:
1.
Consumable components; such as contact tips,
cutting nozzles, contactors, brushes, slip rings,
relays or parts that fail due to normal wear.
(Exception: brushes, slip rings, and relays are
covered on Bobcat, Trailblazer, and Legend models.)
2.
Items furnished by Miller, but manufactured by others,
such as engines or trade accessories. These items are
covered by the manufacturer’s warranty, if any.
3.
Equipment that has been modified by any party other
than Miller, or equipment that has been improperly
installed, improperly operated or misused based upon
industry standards, or equipment which has not had
reasonable and necessary maintenance, or equipment
which has been used for operation outside of the
specifications for the equipment.
MILLER PRODUCTS ARE INTENDED FOR PURCHASE
AND USE BY COMMERCIAL/INDUSTRIAL USERS AND
PERSONS TRAINED AND EXPERIENCED IN THE USE
AND MAINTENANCE OF WELDING EQUIPMENT.
In the event of a warranty claim covered by this warranty, the
exclusive remedies shall be, at Miller’s option: (1) repair; or (2)
replacement; or, where authorized in writing by Miller in
appropriate cases, (3) the reasonable cost of repair or
replacement at an authorized Miller service station; or (4)
payment of or credit for the purchase price (less reasonable
depreciation based upon actual use) upon return of the goods
at customer’s risk and expense. Miller’s option of repair or
replacement will be F.O.B., Factory at Appleton, Wisconsin, or
F.O.B. at a Miller authorized service facility as determined by
Miller. Therefore no compensation or reimbursement for
transportation costs of any kind will be allowed.
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR
DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF
PROFIT), WHETHER BASED ON CONTRACT, TORT OR
ANY OTHER LEGAL THEORY.
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN
AND ANY IMPLIED WARRANTY, GUARANTY OR
REPRESENTATION AS TO PERFORMANCE, AND ANY
REMEDY FOR BREACH OF CONTRACT TORT OR ANY
OTHER LEGAL THEORY WHICH, BUT FOR THIS
PROVISION,
MIGHT
ARISE
BY
IMPLICATION,
OPERATION OF LAW, CUSTOM OF TRADE OR COURSE
OF DEALING, INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR PARTICULAR
PURPOSE, WITH RESPECT TO ANY AND ALL
EQUIPMENT FURNISHED BY MILLER IS EXCLUDED AND
DISCLAIMED BY MILLER.
Some states in the U.S.A. do not allow limitations of how long
an implied warranty lasts, or the exclusion of incidental,
indirect, special or consequential damages, so the above
limitation or exclusion may not apply to you. This warranty
provides specific legal rights, and other rights may be
available, but may vary from state to state.
In Canada, legislation in some provinces provides for certain
additional warranties or remedies other than as stated herein,
and to the extent that they may not be waived, the limitations
and exclusions set out above may not apply. This Limited
Warranty provides specific legal rights, and other rights may
be available, but may vary from province to province.
miller_warr 8/03
Owner’s Record
Please complete and retain with your personal records.
Model Name
Serial/Style Number
Purchase Date
(Date which equipment was delivered to original customer.)
Distributor
Address
City
State
Zip
For Service
Call 1-800-4-A-Miller or see our website at www.MillerWelds.com
to locate a DISTRIBUTOR or SERVICE AGENCY near you.
Always provide Model Name and Serial/Style Number.
Contact your Distributor for:
Welding Supplies and Consumables
Options and Accessories
Personal Safety Equipment
Service and Repair
Miller Electric Mfg. Co.
An Illinois Tool Works Company
1635 West Spencer Street
Appleton, WI 54914 USA
Replacement Parts
Training (Schools, Videos, Books)
International Headquarters−USA
USA Phone: 920-735-4505 Auto-Attended
USA & Canada FAX: 920-735-4134
International FAX: 920-735-4125
Technical Manuals (Servicing Information
and Parts)
Circuit Diagrams
European Headquarters −
United Kingdom
Phone: 44 (0) 1204-593493
FAX: 44 (0) 1204-598066
Welding Process Handbooks
www.MillerWelds.com
Contact the Delivering Carrier to:
File a claim for loss or damage during
shipment.
For assistance in filing or settling claims, contact
your distributor and/or equipment manufacturer’s
Transportation Department.
PRINTED IN USA
 2003 Miller Electric Mfg. Co.
1/03
Was this manual useful for you? yes no