Miller SUITCASE 8VS X-TREME CE AND NON-CE MODELS Owner’s Manual

Add to my manuals
40 Pages

advertisement

Miller SUITCASE 8VS X-TREME CE AND NON-CE MODELS Owner’s Manual | Manualzz
OM-262379L
2018−02
Processes
MIG (GMAW) Welding
Flux Cored (FCAW) Welding
Description
Wire Feeder
SuitCase
8VS X-TREME
™
CE And Non-CE Models
File: MIG (GMAW)
For product information,
Owner’s Manual translations,
and more, visit
www.MillerWelds.com
From Miller to You
Thank you and congratulations on choosing Miller. Now you can get
the job done and get it done right. We know you don’t have time to do
it any other way.
That’s why when Niels Miller first started building arc welders in 1929,
he made sure his products offered long-lasting value and superior
quality. Like you, his customers couldn’t afford anything less. Miller
products had to be more than the best they could be. They had to be the
best you could buy.
Today, the people that build and sell Miller products continue the
tradition. They’re just as committed to providing equipment and service
that meets the high standards of quality and value established in 1929.
This Owner’s Manual is designed to help you get the most out of your
Miller products. Please take time to read the Safety precautions. They
will help you protect yourself against potential hazards on the worksite.
We’ve made installation and operation quick
and easy. With Miller you can count on years
of reliable service with proper maintenance.
And if for some reason the unit needs repair,
there’s a Troubleshooting section that will
help you figure out what the problem is. The
parts list will then help you to decide the
exact part you may need to fix the problem.
Warranty and service information for your
particular model are also provided.
Miller is the first welding
equipment manufacturer in
the U.S.A. to be registered to
the ISO 9001 Quality System
Standard.
Miller Electric manufactures a full line
of welders and welding related equipment.
For information on other quality Miller
products, contact your local Miller distributor to receive the latest full
line catalog or individual specification sheets. To locate your nearest
distributor or service agency call 1-800-4-A-Miller, or visit us at
www.MillerWelds.com on the web.
Mil_Thank1 2017−06
Working as hard as you do
− every power source from
Miller is backed by the most
hassle-free warranty in the
business.
TABLE OF CONTENTS
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4. California Proposition 65 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-6. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1. Symboles utilisés . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2. Dangers relatifs au soudage à l’arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance . . . . . .
2-4. Proposition californienne 65 Avertissements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-5. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-6. Informations relatives aux CEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 − DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1. Additional Safety Symbols And Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2. Miscellaneous Symbols And Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 4 − SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-1. Serial Number And Rating Label Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. Unit Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3. Wire Type, Size, and Feed Speed Capability Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-4. Gun Recommendation Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-5. Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 5 − INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-1. Equipment Connection Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2. Installing Drive Rolls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-3. Connecting Welding Gun And Voltage Sensing Clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-4. Connecting Shielding Gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-5. Connecting Weld Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-6. Selecting Cable Sizes* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-7. Installing And Threading Welding Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-8. Motor Control Board (PC1) DIP Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-9. Meter Board (PC20) DIP Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 − OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-1. Controls With Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-2. Controls Without Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-3. Wire Speed Dual Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-4. Wire Speed Control Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 7 − MAINTENANCE & TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-2. Overload Protection And Thermostat Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-3. Cleaning Debris From Shielding Gas Filter Fitting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-4. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-5. Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 8 − ELECTRICAL DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 9 − PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARRANTY
1
1
1
3
4
4
4
5
5
5
7
8
8
8
9
9
10
11
11
11
11
11
11
12
12
13
14
15
15
16
17
17
18
19
19
20
21
22
23
23
23
24
25
26
27
28
DECLARATION OF CONFORMITY
for European Community (CE marked) products.
MILLER Electric Mfg. Co., 1635 Spencer Street, Appleton, WI 54914 U.S.A. declares that the
product(s) identified in this declaration conform to the essential requirements and provisions of
the stated Council Directive(s) and Standard(s).
Product/Apparatus Identification:
Product
SUITCASE X‐TREME 8VS, HEAVY DUTY
DRIVE
Stock Number
300877
Council Directives:
• 2014/35/EU Low voltage
• 2014/30/EU Electromagnetic compatibility
• 2011/65/EU Restriction of the use of certain hazardous substances in electrical and electronic equipment
Standards:
• IEC 60974­5:2013 Arc welding equipment – Part 5: Wire feeders
• IEC 60974­10:2014 Arc welding equipment – Part 10: Electromagnetic compatibility requirements
Signatory:
March 10, 2017
_____________________________________
___________________________________________
David A. Werba
Date of Declaration
MANAGER, PRODUCT DESIGN COMPLIANCE
266832C
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING
som 2018−01
7
Protect yourself and others from injury — read, follow, and save these important safety precautions and operating instructions.
1-1. Symbol Usage
DANGER! − Indicates a hazardous situation which, if
not avoided, will result in death or serious injury. The
possible hazards are shown in the adjoining symbols
or explained in the text.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury. The possible
hazards are shown in the adjoining symbols or explained in the text.
NOTICE − Indicates statements not related to personal injury.
Indicates special instructions.
This group of symbols means Warning! Watch Out! ELECTRIC
SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult symbols and related instructions below for necessary actions to avoid the
hazards.
1-2. Arc Welding Hazards
The symbols shown below are used throughout this manual
to call attention to and identify possible hazards. When you
see the symbol, watch out, and follow the related instructions
to avoid the hazard. The safety information given below is
only a summary of the more complete safety information
found in the Safety Standards listed in Section 1-5. Read and
follow all Safety Standards.
Only qualified persons should install, operate, maintain, and
repair this equipment. A qualified person is defined as one
who, by possession of a recognized degree, certificate, or
professional standing, or who by extensive knowledge, training and experience, has successfully demonstrated ability to
solve or resolve problems relating to the subject matter, the
work, or the project and has received safety training to recognize and avoid the hazards involved.
During operation, keep everybody, especially children, away.
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shocks
or severe burns. The electrode and work circuit is
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also
live when power is on. In semiautomatic or automatic
wire welding, the wire, wire reel, drive roll housing,
and all metal parts touching the welding wire are
electrically live. Incorrectly installed or improperly
grounded equipment is a hazard.
Do not touch live electrical parts.
Wear dry, hole-free insulating gloves and body protection.
Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.
Do not use AC weld output in damp, wet, or confined spaces, or if
there is a danger of falling.
Use AC output ONLY if required for the welding process.
If AC output is required, use remote output control if present on
unit.
Additional safety precautions are required when any of the following electrically hazardous conditions are present: in damp
locations or while wearing wet clothing; on metal structures such
as floors, gratings, or scaffolds; when in cramped positions such
as sitting, kneeling, or lying; or when there is a high risk of unavoidable or accidental contact with the workpiece or ground. For these
conditions, use the following equipment in order presented: 1) a
semiautomatic DC constant voltage (wire) welder, 2) a DC manual
(stick) welder, or 3) an AC welder with reduced open-circuit voltage. In most situations, use of a DC, constant voltage wire welder
is recommended. And, do not work alone!
Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
Properly install, ground, and operate this equipment according to
its Owner’s Manual and national, state, and local codes.
Always verify the supply ground − check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
grounded receptacle outlet.
When making input connections, attach proper grounding conductor first − double-check connections.
Keep cords dry, free of oil and grease, and protected from hot metal
and sparks.
Frequently inspect input power cord and ground conductor for
damage or bare wiring – replace immediately if damaged – bare
wiring can kill.
Turn off all equipment when not in use.
Do not use worn, damaged, undersized, or repaired cables.
Do not drape cables over your body.
If earth grounding of the workpiece is required, ground it directly
with a separate cable.
Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
Do not touch electrode holders connected to two welding machines at the same time since double open-circuit voltage will be
present.
Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
Wear a safety harness if working above floor level.
Keep all panels and covers securely in place.
Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
Do not connect more than one electrode or work cable to any
single weld output terminal. Disconnect cable for process not in
use.
Use GFCI protection when operating auxiliary equipment in damp
or wet locations.
SIGNIFICANT DC VOLTAGE exists in inverter welding power sources AFTER removal of input power.
Turn off unit, disconnect input power, and discharge input capacitors according to instructions in Manual before touching any parts.
HOT PARTS can burn.
Do not touch hot parts bare handed.
Allow cooling period before working on
equipment.
To handle hot parts, use proper tools and/or wear heavy, insulated welding gloves and clothing to prevent burns.
OM-262379 Page 1
FUMES AND GASES can be hazardous.
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health.
Keep your head out of the fumes. Do not breathe the fumes.
Ventilate the work area and/or use local forced ventilation at the arc
to remove welding fumes and gases. The recommended way to
determine adequate ventilation is to sample for the composition
and quantity of fumes and gases to which personnel are exposed.
If ventilation is poor, wear an approved air-supplied respirator.
Read and understand the Safety Data Sheets (SDSs) and the
manufacturer’s instructions for adhesives, coatings, cleaners,
consumables, coolants, degreasers, fluxes, and metals.
Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watchperson nearby. Welding fumes and gases can displace air and
lower the oxygen level causing injury or death. Be sure the breathing air is safe.
Do not weld in locations near degreasing, cleaning, or spraying operations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.
Do not weld on coated metals, such as galvanized, lead, or
cadmium plated steel, unless the coating is removed from the weld
area, the area is well ventilated, and while wearing an air-supplied
respirator. The coatings and any metals containing these elements
can give off toxic fumes if welded.
ARC RAYS can burn eyes and skin.
Arc rays from the welding process produce intense
visible and invisible (ultraviolet and infrared) rays
that can burn eyes and skin. Sparks fly off from the
weld.
Wear an approved welding helmet fitted with a proper shade of
filter lenses to protect your face and eyes from arc rays and
sparks when welding or watching (see ANSI Z49.1 and Z87.1
listed in Safety Standards).
Wear approved safety glasses with side shields under your
helmet.
Use protective screens or barriers to protect others from flash,
glare and sparks; warn others not to watch the arc.
Wear body protection made from durable, flame−resistant material (leather, heavy cotton, wool). Body protection includes
oil-free clothing such as leather gloves, heavy shirt, cuffless
trousers, high shoes, and a cap.
WELDING can cause fire or explosion.
Welding on closed containers, such as tanks,
drums, or pipes, can cause them to blow up. Sparks
can fly off from the welding arc. The flying sparks, hot
workpiece, and hot equipment can cause fires and
burns. Accidental contact of electrode to metal objects can cause
sparks, explosion, overheating, or fire. Check and be sure the area is
safe before doing any welding.
Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
Do not weld where flying sparks can strike flammable material.
Protect yourself and others from flying sparks and hot metal.
Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
Watch for fire, and keep a fire extinguisher nearby.
Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
OM-262379 Page 2
Do not cut or weld on tire rims or wheels. Tires can explode if heated. Repaired rims and wheels can fail. See OSHA 29 CFR
1910.177 listed in Safety Standards.
Do not weld on containers that have held combustibles, or on
closed containers such as tanks, drums, or pipes unless they are
properly prepared according to AWS F4.1 and AWS A6.0 (see
Safety Standards).
Do not weld where the atmosphere can contain flammable dust,
gas, or liquid vapors (such as gasoline).
Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly
unknown paths and causing electric shock, sparks, and fire
hazards.
Do not use welder to thaw frozen pipes.
Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
Wear body protection made from durable, flame−resistant material
(leather, heavy cotton, wool). Body protection includes oil-free
clothing such as leather gloves, heavy shirt, cuffless trousers, high
shoes, and a cap.
Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.
After completion of work, inspect area to ensure it is free of sparks,
glowing embers, and flames.
Use only correct fuses or circuit breakers. Do not oversize or bypass them.
Follow requirements in OSHA 1910.252 (a) (2) (iv) and NFPA 51B
for hot work and have a fire watcher and extinguisher nearby.
Read and understand the Safety Data Sheets (SDSs) and the
manufacturer’s instructions for adhesives, coatings, cleaners,
consumables, coolants, degreasers, fluxes, and metals.
FLYING METAL or DIRT can injure eyes.
Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool,
they can throw off slag.
Wear approved safety glasses with side
shields even under your welding helmet.
BUILDUP OF GAS can injure or kill.
Shut off compressed gas supply when not in use.
Always ventilate confined spaces or use
approved air-supplied respirator.
ELECTRIC AND MAGNETIC FIELDS (EMF)
can affect Implanted Medical Devices.
Wearers of Pacemakers and other Implanted
Medical Devices should keep away.
Implanted Medical Device wearers should consult their doctor
and the device manufacturer before going near arc welding, spot
welding, gouging, plasma arc cutting, or induction heating
operations.
NOISE can damage hearing.
Noise from some processes or equipment can
damage hearing.
Wear approved ear protection if noise level is high.
CYLINDERS can explode if damaged.
Compressed gas cylinders contain gas under high
pressure. If damaged, a cylinder can explode. Since
gas cylinders are normally part of the welding
process, be sure to treat them carefully.
Protect compressed gas cylinders from excessive heat, mechanical shocks, physical damage, slag, open flames, sparks, and arcs.
Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
Keep cylinders away from any welding or other electrical circuits.
Never drape a welding torch over a gas cylinder.
Never allow a welding electrode to touch any cylinder.
Never weld on a pressurized cylinder − explosion will result.
Use only correct compressed gas cylinders, regulators, hoses,
and fittings designed for the specific application; maintain them
and associated parts in good condition.
Turn face away from valve outlet when opening cylinder valve. Do
not stand in front of or behind the regulator when opening the valve.
Keep protective cap in place over valve except when cylinder is in
use or connected for use.
Use the proper equipment, correct procedures, and sufficient
number of persons to lift, move, and transport cylinders.
Read and follow instructions on compressed gas cylinders,
associated equipment, and Compressed Gas Association (CGA)
publication P-1 listed in Safety Standards.
1-3. Additional Symbols For Installation, Operation, And Maintenance
FIRE OR EXPLOSION hazard.
Do not install or place unit on, over, or near
combustible surfaces.
Do not install unit near flammables.
Do not overload building wiring − be sure power supply system is
properly sized, rated, and protected to handle this unit.
MOVING PARTS can injure.
Keep away from moving parts.
Keep away from pinch points such as drive
rolls.
WELDING WIRE can injure.
FALLING EQUIPMENT can injure.
Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
Use correct procedures and equipment of adequate capacity to lift and support unit.
If using lift forks to move unit, be sure forks are long enough to
extend beyond opposite side of unit.
Keep equipment (cables and cords) away from moving vehicles
when working from an aerial location.
Follow the guidelines in the Applications Manual for the Revised
NIOSH Lifting Equation (Publication No. 94−110) when manually lifting heavy parts or equipment.
Do not press gun trigger until instructed to do
so.
Do not point gun toward any part of the body,
other people, or any metal when threading
welding wire.
BATTERY EXPLOSION can injure.
Do not use welder to charge batteries or jump
start vehicles unless it has a battery charging
feature designed for this purpose.
MOVING PARTS can injure.
OVERUSE can cause OVERHEATING
Allow cooling period; follow rated duty cycle.
Reduce current or reduce duty cycle before
starting to weld again.
Do not block or filter airflow to unit.
FLYING SPARKS can injure.
Wear a face shield to protect eyes and face.
Shape tungsten electrode only on grinder with
proper guards in a safe location wearing proper
face, hand, and body protection.
Sparks can cause fires — keep flammables away.
STATIC (ESD) can damage PC boards.
Put on grounded wrist strap BEFORE handling
boards or parts.
Use proper static-proof bags and boxes to
store, move, or ship PC boards.
Keep away from moving parts such as fans.
Keep all doors, panels, covers, and guards
closed and securely in place.
Have only qualified persons remove doors, panels, covers, or
guards for maintenance and troubleshooting as necessary.
Reinstall doors, panels, covers, or guards when maintenance is
finished and before reconnecting input power.
READ INSTRUCTIONS.
Read and follow all labels and the Owner’s
Manual carefully before installing, operating, or
servicing unit. Read the safety information at
the beginning of the manual and in each
section.
Use only genuine replacement parts from the manufacturer.
Perform installation, maintenance, and service according to the
Owner’s Manuals, industry standards, and national, state, and
local codes.
OM-262379 Page 3
H.F. RADIATION can cause interference.
ARC WELDING can cause interference.
High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communications equipment.
Have only qualified persons familiar with electronic equipment
perform this installation.
The user is responsible for having a qualified electrician promptly correct any interference problem resulting from the installation.
If notified by the FCC about interference, stop using the
equipment at once.
Have the installation regularly checked and maintained.
Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.
Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.
Be sure all equipment in the welding area is electromagnetically
compatible.
To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
Locate welding operation 100 meters from any sensitive electronic equipment.
Be sure this welding machine is installed and grounded
according to this manual.
If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables,
using line filters, or shielding the work area.
1-4. California Proposition 65 Warnings
WARNING: This product can expose you to chemicals including lead, which are known to the state of California to
cause cancer and birth defects or other reproductive
harm.
For more information, go to www.P65Warnings.ca.gov.
1-5. Principal Safety Standards
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
is available as a free download from the American Welding Society at
http://www.aws.org or purchased from Global Engineering Documents
(phone: 1-877-413-5184, website: www.global.ihs.com).
Safe Practices for the Preparation of Containers and Piping for Welding
and Cutting, American Welding Society Standard AWS F4.1, from Global Engineering Documents (phone: 1-877-413-5184, website:
www.global.ihs.com).
Safe Practices for Welding and Cutting Containers that have Held Combustibles, American Welding Society Standard AWS A6.0, from Global
Engineering Documents (phone: 1-877-413-5184,
website: www.global.ihs.com).
National Electrical Code, NFPA Standard 70, from National Fire Protection Association, Quincy, MA 02169 (phone: 1-800-344-3555, website:
www.nfpa.org and www. sparky.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 14501 George Carter Way, Suite
103, Chantilly, VA 20151 (phone: 703-788-2700, website:www.cganet.com).
Safety in Welding, Cutting, and Allied Processes, CSA Standard
W117.2, from Canadian Standards Association, Standards Sales, 5060
Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5NS
(phone: 800-463-6727, website: www.csagroup.org).
Safe Practice For Occupational And Educational Eye And Face Protection, ANSI Standard Z87.1, from American National Standards Institute,
25 West 43rd Street, New York, NY 10036 (phone: 212-642-4900, website: www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, from National Fire Protection Association,
Quincy, MA 02169 (phone: 1-800-344-3555, website: www.nfpa.org).
OSHA, Occupational Safety and Health Standards for General Industry, Title 29, Code of Federal Regulations (CFR), Part 1910.177 Subpart
N, Part 1910 Subpart Q, and Part 1926, Subpart J, from U.S. Government Printing Office, Superintendent of Documents, P.O. Box 371954,
Pittsburgh, PA 15250-7954 (phone: 1-866-512-1800) (there are 10 OSHA Regional Offices—phone for Region 5, Chicago, is 312-353-2220,
website: www.osha.gov).
Applications Manual for the Revised NIOSH Lifting Equation, The National Institute for Occupational Safety and Health (NIOSH), 1600
Clifton Rd, Atlanta, GA 30329-4027 (phone: 1-800-232-4636, website:
www.cdc.gov/NIOSH).
1-6. EMF Information
Electric current flowing through any conductor causes localized electric
and magnetic fields (EMF). The current from arc welding (and allied processes including spot welding, gouging, plasma arc cutting, and
induction heating operations) creates an EMF field around the welding
circuit. EMF fields can interfere with some medical implants, e.g. pacemakers. Protective measures for persons wearing medical implants
have to be taken. For example, restrict access for passers−by or conduct individual risk assessment for welders. All welders should use the
following procedures in order to minimize exposure to EMF fields from
the welding circuit:
1. Keep cables close together by twisting or taping them, or using a
cable cover.
2. Do not place your body between welding cables. Arrange cables
to one side and away from the operator.
3. Do not coil or drape cables around your body.
OM-262379 Page 4
4. Keep head and trunk as far away from the equipment in the
welding circuit as possible.
5. Connect work clamp to workpiece as close to the weld as
possible.
6. Do not work next to, sit or lean on the welding power source.
7. Do not weld whilst carrying the welding power source or wire
feeder.
About Implanted Medical Devices:
Implanted Medical Device wearers should consult their doctor and the
device manufacturer before performing or going near arc welding, spot
welding, gouging, plasma arc cutting, or induction heating operations.
If cleared by your doctor, then following the above procedures is recommended.
SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION
som_2018−01_fre
7
Pour écarter les risques de blessure pour vous−même et pour autrui — lire, appliquer et ranger en lieu sûr ces consignes relatives
aux précautions de sécurité et au mode opératoire.
2-1. Symboles utilisés
DANGER! − Indique une situation dangereuse qui si on
l’évite pas peut donner la mort ou des blessures graves.
Les dangers possibles sont montrés par les symboles
joints ou sont expliqués dans le texte.
Indique une situation dangereuse qui si on l’évite pas
peut donner la mort ou des blessures graves. Les dangers possibles sont montrés par les symboles joints ou
sont expliqués dans le texte.
AVIS − Indique des déclarations pas en relation avec des blessures
personnelles.
Indique des instructions spécifiques.
Ce groupe de symboles veut dire Avertissement! Attention! DANGER
DE CHOC ELECTRIQUE, PIECES EN MOUVEMENT, et PIECES
CHAUDES. Consulter les symboles et les instructions ci-dessous y
afférant pour les actions nécessaires afin d’éviter le danger.
2-2. Dangers relatifs au soudage à l’arc
Les symboles représentés ci-dessous sont utilisés dans ce manuel pour attirer l’attention et identifier les dangers possibles. En
présence de l’un de ces symboles, prendre garde et suivre les
instructions afférentes pour éviter tout risque. Les instructions
en matière de sécurité indiquées ci-dessous ne constituent
qu’un sommaire des instructions de sécurité plus complètes
fournies dans les normes de sécurité énumérées dans la Section 2-5. Lire et observer toutes les normes de sécurité.
L’installation, l’utilisation, l’entretien et les réparations ne
doivent être confiés qu’à des personnes qualifiées. Une
personne qualifiée est définie comme celle qui, par la
possession d’un diplôme reconnu, d’un certificat ou d’un
statut professionnel, ou qui, par une connaissance, une formation et une expérience approfondies, a démontré avec
succès sa capacité à résoudre les problèmes liés à la tâche,
le travail ou le projet et a reçu une formation en sécurité afin
de reconnaître et d’éviter les risques inhérents.
Pendant le fonctionnement, maintenir à distance toutes les
personnes, notamment les enfants de l’appareil.
UNE DÉCHARGE ÉLECTRIQUE peut
entraîner la mort.
Le contact d’organes électriques sous tension peut
provoquer des accidents mortels ou des brûlures
graves. Le circuit de l’électrode et de la pièce est sous
tension lorsque le courant est délivré à la sortie. Le
circuit d’alimentation et les circuits internes de la
machine sont également sous tension lorsque l’alimentation est sur Marche. Dans le mode de soudage avec
du fil, le fil, le dérouleur, le bloc de commande du
rouleau et toutes les parties métalliques en contact
avec le fil sont sous tension électrique. Un équipement
installé ou mis à la terre de manière incorrecte ou
impropre constitue un danger.
Ne pas toucher aux pièces électriques sous tension.
Porter des gants isolants et des vêtements de protection secs et
sans trous.
S’isoler de la pièce à couper et du sol en utilisant des housses ou
des tapis assez grands afin d’éviter tout contact physique avec la
pièce à couper ou le sol.
Ne pas utiliser de sortie de soudage CA dans des zones humides
ou confinées ou s’il y a un risque de chute.
Se servir d’une source électrique à courant électrique UNIQUEMENT si le procédé de soudage le demande.
Si l’utilisation d’une source électrique à courant électrique s’avère
nécessaire, se servir de la fonction de télécommande si l’appareil
en est équipé.
D’autres consignes de sécurité sont nécessaires dans les conditions suivantes : risques électriques dans un environnement
humide ou si l’on porte des vêtements mouillés ; sur des structures
métalliques telles que sols, grilles ou échafaudages ; en position
coincée comme assise, à genoux ou couchée ; ou s’il y a un risque
élevé de contact inévitable ou accidentel avec la pièce à souder ou
le sol. Dans ces conditions, utiliser les équipements suivants,
dans l’ordre indiqué : 1) un poste à souder DC à tension constante
(à fil), 2) un poste à souder DC manuel (électrode) ou 3) un poste à
souder AC à tension à vide réduite. Dans la plupart des situations,
l’utilisation d’un poste à souder DC à fil à tension constante est recommandée. En outre, ne pas travailler seul !
Couper l’alimentation ou arrêter le moteur avant de procéder à l’installation, à la réparation ou à l’entretien de l’appareil. Déverrouiller
l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de sécurité).
Installez, mettez à la terre et utilisez correctement cet équipement
conformément à son Manuel d’Utilisation et aux réglementations
nationales, gouvernementales et locales.
Toujours vérifier la terre du cordon d’alimentation. Vérifier et
s’assurer que le fil de terre du cordon d’alimentation est bien
raccordé à la borne de terre du sectionneur ou que la fiche du
cordon est raccordée à une prise correctement mise à la terre.
En effectuant les raccordements d’entrée, fixer d’abord le conducteur de mise à la terre approprié et contre-vérifier les connexions.
Les câbles doivent être exempts d’humidité, d’huile et de graisse;
protégez−les contre les étincelles et les pièces métalliques
chaudes.
Vérifier fréquemment le cordon d’alimentation et le conducteur de
mise à la terre afin de s’assurer qu’il n’est pas altéré ou dénudé −,
le remplacer immédiatement s’il l’est −. Un fil dénudé peut entraîner la mort.
L’équipement doit être hors tension lorsqu’il n’est pas utilisé.
Ne pas utiliser des câbles usés, endommagés, de grosseur insuffisante ou mal épissés.
Ne pas enrouler les câbles autour du corps.
Si la pièce soudée doit être mise à la terre, le faire directement
avec un câble distinct.
Ne pas toucher l’électrode quand on est en contact avec la pièce,
la terre ou une électrode provenant d’une autre machine.
Ne pas toucher des porte électrodes connectés à deux machines
en même temps à cause de la présence d’une tension à vide doublée.
N’utiliser qu’un matériel en bon état. Réparer ou remplacer sur-lechamp les pièces endommagées. Entretenir l’appareil conformément à ce manuel.
Porter un harnais de sécurité si l’on doit travailler au-dessus du sol.
S’assurer que tous les panneaux et couvercles sont correctement
en place.
Fixer le câble de retour de façon à obtenir un bon contact métalmétal avec la pièce à souder ou la table de travail, le plus près possible de la soudure.
Isoler la pince de masse quand pas mis à la pièce pour éviter le
contact avec tout objet métallique.
Ne pas raccorder plus d’une électrode ou plus d’un câble de
masse à une même borne de sortie de soudage. Débrancher le
câble pour le procédé non utilisé.
Utiliser une protection différentielle lors de l’utilisation d’un équipement auxiliaire dans des endroits humides ou mouillés.
Il reste une TENSION DC NON NÉGLIGEABLE dans
les sources de soudage onduleur UNE FOIS
l’alimentation coupée.
Éteignez l’unité, débranchez le courant électrique, et déchargez
les condensateurs d’alimentation selon les instructions indiquées
dans le manuel avant de toucher les pièces.
OM-262379 Page 5
LES PIÈCES CHAUDES peuvent
provoquer des brûlures.
Ne pas toucher à mains nues les parties chaudes.
Prévoir une période de refroidissement avant
de travailler à l’équipement.
Ne pas toucher aux pièces chaudes, utiliser les outils recommandés et porter des gants de soudage et des vêtements épais pour
éviter les brûlures.
LES FUMÉES ET LES GAZ peuvent
être dangereux.
Le soudage génère des fumées et des gaz. Leur
inhalation peut être dangereux pour votre santé.
Eloigner votre tête des fumées. Ne pas respirer les fumées.
À l’intérieur, ventiler la zone et/ou utiliser une ventilation forcée au
niveau de l’arc pour l’évacuation des fumées et des gaz de
soudage. Pour déterminer la bonne ventilation, il est recommandé
de procéder à un prélèvement pour la composition et la quantité de
fumées et de gaz auxquelles est exposé le personnel.
Si la ventilation est médiocre, porter un respirateur anti-vapeurs
approuvé.
Lire et comprendre les fiches de données de sécurité et les instructions du fabricant concernant les adhésifs, les revêtements, les
nettoyants, les consommables, les produits de refroidissement, les
dégraisseurs, les flux et les métaux.
Travailler dans un espace fermé seulement s’il est bien ventilé ou
en portant un respirateur à alimentation d’air. Demander toujours à
un surveillant dûment formé de se tenir à proximité. Des fumées et
des gaz de soudage peuvent déplacer l’air et abaisser le niveau
d’oxygène provoquant des blessures ou des accidents mortels.
S’assurer que l’air de respiration ne présente aucun danger.
Ne pas souder dans des endroits situés à proximité d’opérations
de dégraissage, de nettoyage ou de pulvérisation. La chaleur et
les rayons de l’arc peuvent réagir en présence de vapeurs et former des gaz hautement toxiques et irritants.
Ne pas souder des métaux munis d’un revêtement, tels que l’acier
galvanisé, plaqué en plomb ou au cadmium à moins que le revêtement n’ait été enlevé dans la zone de soudure, que l’endroit soit
bien ventilé, et en portant un respirateur à alimentation d’air. Les
revêtements et tous les métaux renfermant ces éléments peuvent
dégager des fumées toxiques en cas de soudage.
LES RAYONS DE L’ARC peuvent
provoquer des brûlures dans les
yeux et sur la peau.
Le rayonnement de l’arc du procédé de soudage génère
des rayons visibles et invisibles intenses (ultraviolets e
infrarouges) susceptibles de provoquer des brûlures dans les yeux et sur la
peau. Des étincelles sont projetées pendant le soudage.
Porter un casque de soudage approuvé muni de verres filtrants
approprié pour protéger visage et yeux pour protéger votre visage
et vos yeux pendant le soudage ou pour regarder (voir ANSI Z49.1
et Z87.1 énuméré dans les normes de sécurité).
Porter des lunettes de sécurité avec écrans latéraux même sous
votre casque.
Avoir recours à des écrans protecteurs ou à des rideaux pour
protéger les autres contre les rayonnements les éblouissements
et les étincelles ; prévenir toute personne sur les lieux de ne pas
regarder l’arc.
Porter un équipement de protection pour le corps fait d’un matériau
résistant et ignifuge (cuir, coton robuste, laine). La protection du
corps comporte des vêtements sans huile comme par ex. des
gants de cuir, une chemise solide, des pantalons sans revers, des
chaussures hautes et une casquette.
Déplacer toutes les substances inflammables à une distance de
10,7 m de l’arc de soudage. En cas d’impossibilité les recouvrir
soigneusement avec des protections homologués.
Ne pas souder dans un endroit là où des étincelles peuvent tomber
sur des substances inflammables.
Se protéger et d’autres personnes de la projection d’étincelles et
de métal chaud.
Des étincelles et des matériaux chauds du soudage peuvent
facilement passer dans d’autres zones en traversant de petites
fissures et des ouvertures.
Surveiller tout déclenchement d’incendie et tenir un extincteur à
proximité.
Le soudage effectué sur un plafond, plancher, paroi ou séparation
peut déclencher un incendie de l’autre côté.
Ne pas couper ou souder des jantes ou des roues. Les pneus
peuvent exploser s’ils sont chauffés. Les jantes et les roues réparées peuvent défaillir. Voir OSHA 29 CFR 1910.177 énuméré dans
les normes de sécurité.
Ne pas effectuer le soudage sur des conteneurs fermés tels que
des réservoirs, tambours, ou conduites, à moins qu’ils n’aient été
préparés correctement conformément à AWS F4.1 et AWS A6.0
(voir les Normes de Sécurité).
Ne pas souder là où l’air ambiant pourrait contenir des poussières,
gaz ou émanations inflammables (vapeur d’essence, par exemple).
Brancher le câble de masse sur la pièce le plus près possible de la
zone de soudage pour éviter le transport du courant sur une
longue distance par des chemins inconnus éventuels en provoquant des risques d’électrocution, d’étincelles et d’incendie.
Ne pas utiliser le poste de soudage pour dégeler des conduites gelées.
En cas de non utilisation, enlever la baguette d’électrode du porteélectrode ou couper le fil à la pointe de contact.
Porter un équipement de protection pour le corps fait d’un matériau
résistant et ignifuge (cuir, coton robuste, laine). La protection du
corps comporte des vêtements sans huile comme par ex. des
gants de cuir, une chemise solide, des pantalons sans revers, des
chaussures hautes et une casquette.
Avant de souder, retirer toute substance combustible de vos poches telles qu’un allumeur au butane ou des allumettes.
Une fois le travail achevé, assurez−vous qu’il ne reste aucune
trace d’étincelles incandescentes ni de flammes.
Utiliser exclusivement des fusibles ou coupe−circuits appropriés.
Ne pas augmenter leur puissance; ne pas les ponter.
Suivre les recommandations dans OSHA 1910.252(a)(2)(iv) et
NFPA 51B pour les travaux à chaud et avoir de la surveillance et un
extincteur à proximité.
Lire et comprendre les fiches de données de sécurité et les instructions du fabricant concernant les adhésifs, les revêtements, les
nettoyants, les consommables, les produits de refroidissement,
les dégraisseurs, les flux et les métaux.
DES PIECES DE METAL ou DES
SALETES peuvent provoquer des
blessures dans les yeux.
Le soudage, l’écaillement, le passage de la pièce à
la brosse en fil de fer, et le meulage génèrent des étincelles et des
particules métalliques volantes. Pendant la période de refroidissement des soudures, elles risquent de projeter du laitier.
Porter des lunettes de sécurité avec écrans latéraux ou un écran
facial.
LE SOUDAGE peut provoquer un
incendie ou une explosion.
Le soudage effectué sur des conteneurs fermés tels
que des réservoirs, tambours ou des conduites peut
provoquer leur éclatement. Des étincelles peuvent
être projetées de l’arc de soudure. La projection d’étincelles, des
pièces chaudes et des équipements chauds peut provoquer des incendies et des brûlures. Le contact accidentel de l’électrode avec des
objets métalliques peut provoquer des étincelles, une explosion, un surchauffement ou un incendie. Avant de commencer le soudage, vérifier
et s’assurer que l’endroit ne présente pas de danger.
OM-262379 Page 6
LES ACCUMULATIONS DE GAZ
risquent de provoquer des blessures
ou même la mort.
Fermer l’alimentation du gaz comprimé en cas
de non utilisation.
Veiller toujours à bien aérer les espaces confinés ou se servir d’un
respirateur d’adduction d’air homologué.
Les CHAMPS ÉLECTROMAGNÉTIQUES (CEM)
peuvent affecter les implants médicaux.
Les porteurs de stimulateurs cardiaques et
autres implants médicaux doivent rester à
distance.
Les porteurs d’implants médicaux doivent consulter leur médecin
et le fabricant du dispositif avant de s’approcher de la zone où se
déroule du soudage à l’arc, du soudage par points, du gougeage,
de la découpe plasma ou une opération de chauffage par
induction.
LE BRUIT peut endommager l’ouïe.
Le bruit des processus et des équipements peut
affecter l’ouïe.
Porter des protections approuvées pour les
oreilles si le niveau sonore est trop élevé.
LES BOUTEILLES peuvent exploser
si elles sont endommagées.
Les bouteilles de gaz comprimé contiennent du
gaz sous haute pression. Si une bouteille est
endommagée, elle peut exploser. Du fait que
les bouteilles de gaz font normalement partie du procédé de
soudage, les manipuler avec précaution.
Protéger les bouteilles de gaz comprimé d’une chaleur excessive,
des chocs mécaniques, des dommages physiques, du laitier, des
flammes ouvertes, des étincelles et des arcs.
Placer les bouteilles debout en les fixant dans un support stationnaire ou dans un porte-bouteilles pour les empêcher de tomber ou
de se renverser.
Tenir les bouteilles éloignées des circuits de soudage ou autres
circuits électriques.
Ne jamais placer une torche de soudage sur une bouteille à gaz.
Une électrode de soudage ne doit jamais entrer en contact avec
une bouteille.
Ne jamais souder une bouteille pressurisée − risque d’explosion.
Utiliser seulement des bouteilles de gaz comprimé, régulateurs,
tuyaux et raccords convenables pour cette application spécifique;
les maintenir ainsi que les éléments associés en bon état.
Tourner le dos à la sortie de vanne lors de l’ouverture de la vanne
de la bouteille. Ne pas se tenir devant ou derrière le régulateur lors
de l’ouverture de la vanne.
Le couvercle du détendeur doit toujours être en place, sauf lorsque
la bouteille est utilisée ou qu’elle est reliée pour usage ultérieur.
Utilisez les équipements corrects, les bonnes procédures et suffisamment de personnes pour soulever, déplacer et transporter les
bouteilles.
Lire et suivre les instructions sur les bouteilles de gaz comprimé,
l’équipement connexe et le dépliant P-1 de la CGA (Compressed Gas
Association) mentionné dans les principales normes de sécurité.
2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance
Risque D’INCENDIE OU D’EXPLOSION.
Ne pas placer l’appareil sur, au-dessus ou
à proximité de surfaces inflammables.
Ne pas installer l’appareil à proximité de produits inflammables.
Ne pas surcharger l’installation électrique − s’assurer que
l’alimentation est correctement dimensionnée et protégée avant
de mettre l’appareil en service.
LA CHUTE DE L’ÉQUIPEMENT peut
provoquer des blessures.
Utiliser l’anneau de levage uniquement pour
soulever l’appareil, NON PAS les chariots, les
bouteilles de gaz ou tout autre accessoire.
Utilisez les procédures correctes et des équipements d’une capacité appropriée pour soulever et supporter l’appareil.
En utilisant des fourches de levage pour déplacer l’unité, s’assurer
que les fourches sont suffisamment longues pour dépasser du
côté opposé de l’appareil.
Tenir l’équipement (câbles et cordons) à distance des véhicules
mobiles lors de toute opération en hauteur.
Suivre les consignes du Manuel des applications pour l’équation
de levage NIOSH révisée (Publication Nº94–110) lors du levage
manuelle de pièces ou équipements lourds.
L’EMPLOI EXCESSIF peut
SURCHAUFFER L’ÉQUIPEMENT.
Prévoir une période de refroidissement ; respecter le cycle opératoire nominal.
Réduire le courant ou le facteur de marche
avant de poursuivre le soudage.
Ne pas obstruer les passages d’air du poste.
LES ÉTINCELLES PROJETÉES
peuvent provoquer des blessures.
Porter un écran facial pour protéger le visage et
les yeux.
Affûter l’électrode au tungstène uniquement à
la meuleuse dotée de protecteurs. Cette manœuvre est à exécuter dans un endroit sûr lorsque l’on porte l’équipement homologué de protection du visage, des mains et du corps.
Les étincelles risquent de causer un incendie − éloigner toute
substance inflammable.
LES CHARGES ÉLECTROSTATIQUES peuvent endommager les circuits imprimés.
Établir la connexion avec la barrette de terre
avant de manipuler des cartes ou des pièces.
Utiliser des pochettes et des boîtes antistatiques pour stocker, déplacer ou expédier des cartes de circuits imprimes.
Les PIÈCES MOBILES peuvent
causer des blessures.
Ne pas s’approcher des organes mobiles.
Ne pas s’approcher des points de coincement
tels que des rouleaux de commande.
LES FILS DE SOUDAGE peuvent
provoquer des blessures.
Ne pas appuyer sur la gâchette avant d’en
avoir reçu l’instruction.
Ne pas diriger le pistolet vers soi, d’autres
personnes ou toute pièce mécanique en engageant le fil de
soudage.
L’EXPLOSION DE LA BATTERIE
peut provoquer des blessures.
Ne pas utiliser l’appareil de soudage pour
charger des batteries ou faire démarrer des
véhicules à l’aide de câbles de démarrage,
sauf si l’appareil dispose d’une fonctionnalité
de charge de batterie destinée à cet usage.
Les PIÈCES MOBILES peuvent
causer des blessures.
S’abstenir de toucher des organes mobiles tels
que des ventilateurs.
Maintenir fermés et verrouillés les portes,
panneaux, recouvrements et dispositifs de protection.
Lorsque cela est nécessaire pour des travaux d’entretien et de dépannage, faire retirer les portes, panneaux, recouvrements ou
dispositifs de protection uniquement par du personnel qualifié.
Remettre les portes, panneaux, recouvrements ou dispositifs de
protection quand l’entretien est terminé et avant de rebrancher
l’alimentation électrique.
OM-262379 Page 7
LIRE LES INSTRUCTIONS.
Lire et appliquer les instructions sur les
étiquettes et le Mode d’emploi avant l’installation, l’utilisation ou l’entretien de l’appareil.
Lire les informations de sécurité au début du
manuel et dans chaque section.
Effectuer régulièrement le contrôle et l’entretien de l’installation.
Maintenir soigneusement fermés les portes et les panneaux des
sources de haute fréquence, maintenir les éclateurs à une distance correcte et utiliser une terre et un blindage pour réduire les
interférences éventuelles.
LE SOUDAGE À L’ARC risque de
provoquer des interférences.
N’utiliser que les pièces de rechange recommandées par le
constructeur.
L’énergie électromagnétique risque de
provoquer des interférences pour l’équipement
électronique sensible tel que les ordinateurs et
l’équipement commandé par ordinateur tel que
les robots.
Effectuer l’installation, l’entretien et toute intervention selon les
manuels d’utilisateurs, les normes nationales, provinciales et de
l’industrie, ainsi que les codes municipaux.
LE
RAYONNEMENT
HAUTE
FRÉQUENCE
(H.F.)
risque
de
provoquer des interférences.
Le rayonnement haute fréquence (H.F.) peut
provoquer des interférences avec les équipements de radio−navigation et de communication, les services
de sécurité et les ordinateurs.
Demander seulement à des personnes qualifiées familiarisées avec
des équipements électroniques de faire fonctionner l’installation.
L’utilisateur est tenu de faire corriger rapidement par un électricien
qualifié les interférences résultant de l’installation.
Si le FCC signale des interférences, arrêter immédiatement l’appareil.
Veiller à ce que tout l’équipement de la zone de soudage soit compatible électromagnétiquement.
Pour réduire la possibilité d’interférence, maintenir les câbles de
soudage aussi courts que possible, les grouper, et les poser aussi
bas que possible (ex. par terre).
Veiller à souder à une distance de 100 mètres de tout équipement
électronique sensible.
Veiller à ce que ce poste de soudage soit posé et mis à la terre
conformément à ce mode d’emploi.
En cas d’interférences après avoir pris les mesures précédentes,
il incombe à l’utilisateur de prendre des mesures supplémentaires
telles que le déplacement du poste, l’utilisation de câbles blindés,
l’utilisation de filtres de ligne ou la pose de protecteurs dans la zone
de travail.
2-4. Proposition californienne 65 Avertissements
AVERTISSEMENT : ce produit peut vous exposer à des produits chimiques tels que le plomb, reconnus par l’État de
Californie comme cancérigènes et sources de malformations
ou d’autres troubles de la reproduction.
Pour plus d’informations, consulter www.P65Warnings.ca.gov.
2-5. Principales normes de sécurité
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
is available as a free download from the American Welding Society at
http://www.aws.org or purchased from Global Engineering Documents
(phone: 1-877-413-5184, website: www.global.ihs.com).
Safe Practices for the Preparation of Containers and Piping for Welding
and Cutting, American Welding Society Standard AWS F4.1, from Global
Engineering Documents (phone: 1-877-413-5184, website: www.global.ihs.com).
Safe Practices for Welding and Cutting Containers that have Held Combustibles, American Welding Society Standard AWS A6.0, from Global
Engineering Documents (phone: 1-877-413-5184,
website: www.global.ihs.com).
National Electrical Code, NFPA Standard 70, from National Fire Protection Association, Quincy, MA 02169 (phone: 1-800-344-3555, website:
www.nfpa.org and www. sparky.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 14501 George Carter Way, Suite
103, Chantilly, VA 20151 (phone: 703-788-2700, website:www.cganet.com).
Safety in Welding, Cutting, and Allied Processes, CSA Standard W117.2,
from Canadian Standards Association, Standards Sales, 5060 Spec-
trum Way, Suite 100, Mississauga, Ontario, Canada L4W 5NS (phone:
800-463-6727, website: www.csagroup.org).
Safe Practice For Occupational And Educational Eye And Face Protection, ANSI Standard Z87.1, from American National Standards Institute,
25 West 43rd Street, New York, NY 10036 (phone: 212-642-4900, website: www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, from National Fire Protection Association,
Quincy, MA 02169 (phone: 1-800-344-3555, website: www.nfpa.org).
OSHA, Occupational Safety and Health Standards for General Industry,
Title 29, Code of Federal Regulations (CFR), Part 1910.177 Subpart N,
Part 1910 Subpart Q, and Part 1926, Subpart J, from U.S. Government
Printing Office, Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954 (phone: 1-866-512-1800) (there are 10 OSHA
Regional Offices—phone for Region 5, Chicago, is 312-353-2220, website: www.osha.gov).
Applications Manual for the Revised NIOSH Lifting Equation, The National Institute for Occupational Safety and Health (NIOSH), 1600 Clifton Rd,
Atlanta, GA 30329-4027 (phone: 1-800-232-4636, website:
www.cdc.gov/NIOSH).
2-6. Informations relatives aux CEM
Le courant électrique qui traverse tout conducteur génère des champs
électromagnétiques (CEM) à certains endroits. Le courant issu d’un
soudage à l’arc (et de procédés connexes, y compris le soudage par
points, le gougeage, le découpage plasma et les opérations de
chauffage par induction) crée un champ électromagnétique (CEM)
autour du circuit de soudage. Les champs électromagnétiques produits
peuvent causer interférence à certains implants médicaux, p. ex. les
stimulateurs cardiaques. Des mesures de protection pour les porteurs
d’implants médicaux doivent être prises: Limiter par exemple tout accès
aux passants ou procéder à une évaluation des risques individuels pour
les soudeurs. Tous les soudeurs doivent appliquer les procédures
suivantes pour minimiser l’exposition aux CEM provenant du circuit de
soudage:
1. Rassembler les câbles en les torsadant ou en les attachant avec
du ruban adhésif ou avec une housse.
2. Ne pas se tenir au milieu des câbles de soudage. Disposer les
OM-262379 Page 8
câbles d’un côté et à distance de l’opérateur.
3. Ne pas courber et ne pas entourer les câbles autour de votre
corps.
4. Maintenir la tête et le torse aussi loin que possible du matériel du
circuit de soudage.
5. Connecter la pince sur la pièce aussi près que possible de la
soudure.
6. Ne pas travailler à proximité d’une source de soudage, ni
s’asseoir ou se pencher dessus.
7. Ne pas souder tout en portant la source de soudage ou le
dévidoir.
En ce qui concerne les implants médicaux :
Les porteurs d’implants doivent d’abord consulter leur médecin avant
de s’approcher des opérations de soudage à l’arc, de soudage par points,
de gougeage, du coupage plasma ou de chauffage par induction. Si le
médecin approuve, il est recommandé de suivre les procédures précédentes.
SECTION 3 − DEFINITIONS
3-1. Additional Safety Symbols And Definitions
Some symbols are found only on CE products.
Warning! Watch Out! There are possible hazards as shown by the symbols.
Safe1 2012−05
Do not discard product (where applicable) with general waste.
Reuse or recycle Waste Electrical and Electronic Equipment (WEEE) by disposing at a designated collection
facility.
Contact your local recycling office or your local distributor for further information.
Safe37 2017−04
Wear dry insulating gloves. Do not touch electrode with bare hand. Do not wear wet or damaged gloves.
Safe2 2017−04
Protect yourself from electric shock by insulating yourself from work and ground.
Safe3 2017−04
Disconnect input plug or power before working on machine.
Safe5 2017−04
Keep your head out of the fumes.
Safe6 2017−04
Use forced ventilation or local exhaust to remove the fumes.
Safe60 2012−06
Use ventilating fan to remove fumes.
Safe61 2012−06
Keep flammables away from welding. Do not weld near flammables.
Safe62 2012−06
OM-262379 Page 9
Welding sparks can cause fires. Have a fire extinguisher nearby, and have a watchperson ready to use it.
Safe63 2012−06
Do not weld on drums or any closed containers.
Safe16 2017−04
Do not remove or paint over (cover) the label.
Safe20 2017−04
Drive rolls can injure fingers.
Safe32 2012−05
Welding wire and drive parts are at welding voltage during operation − keep hands and metal objects away.
Safe33 2017−04
Wear hat and safety glasses. Use ear protection and button shirt
collar. Use welding helmet with correct shade of filter. Wear complete
body protection.
Safe66 2012−06
Become trained and read the instructions before working on the
machine or welding.
Safe65 2012−06
3-2. Miscellaneous Symbols And Definitions
Filter
A
V
IP
OM-262379 Page 10
Trigger Hold On
Percent
Amperes
Purge By Gas
U1
Input Voltage
Run-In
Volts
Constant Voltage
Degree Of
Protection
I2
Rated Welding
Current
Line Connection
Off
Gas IN
Wire Feed
Increase
Cold Jog (Inch)
Towards Workpiece
On
Supplementary
Protector
I1
Input Current
Input
Constant Current
Trigger Hold Off
Read Instructions
SECTION 4 − SPECIFICATIONS
4-1. Serial Number And Rating Label Location
The serial number and rating information for this product is located inside the door. Use rating label to determine input power requirements and/or rated
output. For future reference, write serial number in space provided on back cover of this manual.
4-2. Unit Specifications
Type of
Input
Power
Welding
Power
Source
Type
Wire Feed
Speed*
Open-Circuit/
Arc Voltage,
14 − 110
Volts DC
Constant
Voltage (CV)
Or Constant
Current (CC)
DC Power
Source Only
25 − 800 ipm
(0.64 − 20.3
mpm)
Depending On
Arc Voltage
Wire
Diameter
Range
Max. Wire
Spool
Capacity
Input Welding
Circuit Rating
Solid Wire:
.023 - .052 in.
(0.6 To 1.3 mm)
Weight
Length: 18 in.
(457 mm)
230 Amperes At
100% Duty Cycle
Flux Cored:
.030 - 5/64 in.
(0.8 To 2 mm)
Overall
Dimensions
14 lb (6.4 kg),
8 in. (203 mm)
330 Amperes At
60% Duty Cycle
Width: 7-1/4 in.
(184 mm)
28 lb
(13 kg)
Height: 12-3/4 in.
(324 mm)
*See Section 4-3 for detailed wire type, size, and rated speed range
4-3. Wire Type, Size, and Feed Speed Capability Table
Motor Speed
Wire Type
Wire Size
Rated Speed Range*
Solid Wire:
.023 - .052 in.
(0.6 To 1.3 mm)
Standard
50 to 780 ipm
(1.3 -19.8 mpm)
All
Flux Cored:
.030 - 5/64 in.
(0.8 To 2 mm)
*Rated speed range per IEC 60974-5
4-4. Gun Recommendation Table
Process
Gun
GMAW − Hard or Cored Wires
Bernard Q-Gun
Tregaskiss Tough Gun
Roughneck C-Series
FCAW − Self-Shielding Wires
Bernard Dura-Flux Gun
Ironmate Series
4-5. Environmental Specifications
A. IP Rating
IP Rating
IP23
This equipment is designed for outdoor use.
IP23 2017−02
B. Temperature Specifications
Operating Temperature Range
Storage Temperature Range
14 to 104°F (−10 to 40°C)
−4 to 131°F (−20 to 55°C)
Temp_2016- 07
C. Information On Electromagnetic Compatibility (EMC)
!
This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low−
voltage supply system. There can be potential difficulties in ensuring electromagnetic compatibility in those locations, due to conducted as well as radiated disturbances.
ce-emc 3 2014-07
OM-262379 Page 11
SECTION 5 − INSTALLATION
5-1. Equipment Connection Diagram
10
!
Turn Off wire feeder and
welding power source. Stop
engine on welding
generator.
!
Do not move or operate
equipment where it could
tip.
!
Use only with CC/CV DC
Power Sources.
1
Constant Current (CC) or
Constant Voltage (CV)
Welding Power Supply
Weld Cable To Feeder
Work Cable To Workpiece
1
2
3
Weld cable and work cable connections to power source (DCEN/
DCEP) are dependant on wire type.
Since feeder is not polarity sen-
2
sitive, there is no need for an
electrode polarity switch.
9
8
4
5
3
Workpiece
Voltage Sensing Clamp
Connect voltage sensing clamp to
workpiece.
7
4
5
6
7
8
9
10
Gun
Gun Trigger Receptacle
Wire Feeder
Gas Hose
Gas Cylinder
Use of shielding gas is dependant
on wire type.
6
Shielding gas pressure not to
exceed 100 psi (689 kPa).
Ref. 265 366-A
Notes
OM-262379 Page 12
5-2. Installing Drive Rolls
Installing Drive Rolls:
1
2
Installing Drive Rolls
Drive Securing Roll Nut
Drive Roll Carrier
Turn nut one click until lobes of nut
line up with lobes of drive roll carrier.
3
Drive Roll
Slide drive roll onto drive roll carrier.
Turn nut one click.
Repeat procedure for top drive roll.
2
Cleaning Drive Rolls:
Remove drive rolls, and clean
grooves using a wire brush.
3
1
265 367-A
Notes
OM-262379 Page 13
5-3. Connecting Welding Gun And Voltage Sensing Clamp
5
!
Turn Off wire feeder and
welding power source.
Stop engine on welding
generator.
!
Weld voltage is present at
voltage sensing clamp
when wire feeder and
welding power source are
on. This condition exists
even if wire feeder lights
and meters are off.
2
5
Turn off wire feeder or
welding power source before handling or moving
voltage sensing clamp.
1
2
3
4
5
Gun Securing Knob
Gun Block
Gun Power Pin
Power Pin Groove
Gun Locking Tab
Loosen gun securing knob, insert
gun power pin into gun block. Position power pin as close as possible to drive rolls without touching. Align the gun power pin
groove with the gun locking tab.
Tighten gun securing knob.
1
Gun Locking Tab In Place
Gun Locking Tab Out Of Place
If the gun power pin does not
have a groove, loosen knob to rotate the gun locking tab 180 degrees. This prevents the the gun
locking tab from interfering with
the gun power pin when inserted
into the gun block. Insert the gun
power pin into the gun block. Position power pin as close as possible to drive rolls without touching them. Tighten gun securing
knob.
6
7
Gun Trigger Plug
Gun Trigger Receptacle
Connect gun trigger plug to gun
trigger receptacle.
See Section 6-3 to make wire
speed dual schedule connections to gun trigger receptacle.
8
Internal Side View
3
Voltage Sensing Clamp
Connect voltage sensing clamp
to workpiece.
4
8
6
7
256 617-A / 265 369-B
OM-262379 Page 14
5-4. Connecting Shielding Gas
NOTICE − This feeder has a shielding gas filter that requires special
attention when cleaning. See Section 7-3 for proper cleaning instructions.
4
3
1
Rear View
Gas Hose With 5/8-18
Right-hand Thread Fittings
(User−Supplied)
Tighten gas
hose fitting to a
maximum of 100 in. lbs (12
N.m).
2
Shielding Gas Cylinder
Shielding gas pressure not to
2
exceed 100 psi (689 kPa).
3
4
Valve
Flowmeter
Close valve on cylinder when finished welding.
1
265 370-A
5-5. Connecting Weld Cable
!
Turn Off wire feeder and
welding power source. Stop
engine on welding
generator.
1
User-Supplied Weld Cable
Follow wire manufacturer’s recommendations for weld cable polarity.
2
3
Male Connector
User-Supplied Female
Connector
Connect male
connectors.
and
female
2
1
3
265 371-A
OM-262379 Page 15
5-6. Selecting Cable Sizes*
!
Turn off power before connecting to weld output terminals.
!
Do not use worn, damaged, undersized, or repaired cables.
NOTICE − The Total Cable Length in Weld Circuit (see table below) is the combined length of both weld cables. For example, if the power source
is 100 ft (30 m) from the workpiece, the total cable length in the weld circuit is 200 ft (2 cables x 100 ft). Use the 200 ft (60 m) column to determine
cable size.
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit
Not Exceeding***
100 ft (30 m) or Less
Welding
Amperes
10 − 60%
Duty
Cycle
AWG (mm2)
150 ft
(45 m)
200 ft
(60 m)
60 − 100%
Duty Cycle
250 ft
(70 m)
300 ft
(90 m)
350 ft
(105 m)
400 ft
(120 m)
10 − 100% Duty Cycle
AWG (mm2)
AWG (mm2)
100
4 (20)
4 (20)
4 (20)
3 (30)
2 (35)
1 (50)
1/0 (60)
1/0 (60)
150
3 (30)
3 (30)
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
3/0 (95)
200
3 (30)
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
4/0 (120)
250
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2x2/0 (2x70)
2x2/0 (2x70)
300
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2x2/0 (2x70)
2x3/0 (2x95)
2x3/0 (2x95)
350
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2x2/0 (2x70)
2x3/0 (2x95)
2x3/0 (2x95)
2x4/0 (2x120)
400
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2x2/0 (2x70)
2x3/0 (2x95)
2x4/0 (2x120)
2x4/0 (2x120)
* This
chart is a general guideline and may not suit all applications. If cable overheats, use next size larger cable.
**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
( ) = mm2 for metric use.
***For distances longer than those shown in this guide, see AWS Fact Sheet No. 39, Welding Cables, available from the American Welding
Society at http://www.aws.org.
Ref. S-0007-M 2017−08
Notes
OM-262379 Page 16
5-7. Installing And Threading Welding Wire
Installing Wire And Adjusting Hub
Tension:
1
2
Retaining Nut
Hub Tension Adjustment Knob
Remove retaining nut, and install spool
so hub pin fits spool hole. Reinstall retaining nut.
Hold wire tightly to keep
Adjust tension knob so only a slight
force is needed to turn spool.
it from unraveling.
Do not over tighten tension knob. It
is not necessary to use any tools to
tighten the knob.
3
Threading Welding Wire:
3
Pressure Adjustment Knob
Lay gun cable out straight.
1
Open pressure assembly. Hold wire
tightly and cut off end. Guide wire
between alignment pins, into drive roll
grooves, and into gun liner.
2
Close pressure assembly and tighten
pressure adjustment knob enough to
feed wire. Press jog switch until wire
comes out of gun.
To set proper drive roll pressure, release the pressure on the drive rolls by
loosening the pressure adjustment
knob. Position gun at about a 45 degree
angle, with nozzle about two inches
from a wooden surface. While feeding
the wire against the wooden surface,
increase the pressure to one half turn
past the point where the wire stops slipping. If the wire slips at maximum
hand-tight pressure, there may be other
problems. Check the gun liner, spool
tension, contact tip and drive roll wear,
as all these can cause wire feeding
problems.
6 in.
(150 mm)
Pull and hold wire; cut off end.
Tighten
Clockwise
WOOD
Cut off wire, and close door.
265 372-A
5-8. Motor Control Board (PC1) DIP Switch Settings
1
2
3
Motor Control Board (PC1)
DIP Switch SW1
LED5
DIP switch SW1 is used to match the
performance of PC1 to the characteristics of the motor used in the feeder.
Setting SW1 as shown will help
ensure that PC1 and motor are
matched for optimal performance.
OPEN
RC111
If protective coating is present, remove
before setting DIP switch. It is not necessary to reapply the protective coating.
Set switch positions 1 and 2 so the depressed section of both tabs are toward 1
and 2 as labeled on the switch. As shown
in illustration.
1
2
When feeder is powered up, LED 5 on the
Motor Control Board (PC1) will blink four
times. This blinking indicates everything
is working properly and the DIP switch is
set correctly.
247 678-B
After LED 5 is done blinking, it will be
either red or green. Red indicates that the
feeder is connected with electrode positive. Green indicates feeder is connected
with electrode negative.
OM-262379 Page 17
5-9. Meter Board (PC20) DIP Switch Settings
1 2 3 4 5
Meter Board (PC20) DIP Switch Settings
Shows switch in ON/DOWN (closed) position
Shows switch in OFF/UP (open) position
Indicates switch does not affect this function
1 2 3 4 5
1 2 3 4 5
1 2
3
4 5
Factory Default DIP Switch Settings To
Display Wire Speed As Inches Per Minute
1 2
3
1 2 3 4 5
4 5
Display Hold Off
Displays will not hold values. Immediately, when
the trigger is released, the Voltmeter will show
open circuit voltage or weld voltage polarity. The
Wire Speed / Amperage Meter will display preset
Wire Speed when the trigger is released.
Do Not Display Amperage
Wire Speed / Amperage Meter will display only
Wire Speed.
Display Amperage
Wire Speed / Amperage Meter will display Amps
while welding and Wire Speed while not welding.
If the hold function is enabled, Amps will be displayed during hold also.
1 2 3 4 5
Wire Speed − Inches per Minute
Displays Wire Speed in Inches per Minute.
1 2 3 4 5
Wire Speed − Meters per Minute
Displays Wire Speed in Meters per Minute.
Factory Default DIP Switch Settings To
Display Wire Speed As Meters Per Minute
1 2 3 4 5
Indicates switch does
not affect this function
Display Hold On
Displays will hold their last value for five seconds
after the trigger is released. After the hold times
out, the Voltmeter will show open circuit voltage or
weld voltage polarity. If the Wire Speed / Amperage Meter is set to display Amps, the amperage
value will hold, after the hold times out, preset Wire
Speed will be displayed.
1 2 3 4 5
Information Off
Information is not displayed.
Information On
With switch in ON position, at feeder power up,
feeder will display various sets of information.
Each set of information will be displayed for three
seconds.
Meter Board (PC20) Software Part Number
Top display will show the first three digits, bottom
display will show last three digits of the Meter
board (PC20) software revision level.
Motor Control Board (PC1) Software Part
Number
Top display will show the first three digits, bottom
display will show last three digits, of the Motor
Control Board (PC1) software revision level.
DIP switch is
located behind
front panel as
shown.
Accumulated Weld Time
This is the time the feeder has actually been used
for welding. This information will be displayed in
two halves. First being years and days, second in
hours and minutes. Top display will show years/
hours, bottom display will show days/minutes.
Weld Voltage Polarity
When the Voltmeter would normally display open
circuit voltage, the Voltmeter will display:
“EP” when connected as electrode positive. While
welding, and in Display Hold On mode, the Voltmeter will display Weld Voltage.
“En.” when connected as electrode negative.
While welding, and in Display Hold On mode, the
Voltmeter will display Weld Voltage and the last
decimal point will remain lit. If Weld Voltage is
“23.4” the Voltmeter will display “23.4.”.
265 368-B
OM-262379 Page 18
SECTION 6 − OPERATION
6-1. Controls With Meters
1
Voltmeter
Displays actual arc voltage or open circuit voltage at the feeder.
2
Wire Speed / Amperage Meter
Displays preset wire speed. While welding in CC
mode, actual wire speed is dependant on arc
voltage. To set wire speed display to: Inches per
Minute or Meters per Minute, see Section 5-9.
Amperage displayed at the feeder is approximate. Refer to power source for actual amperage. To display Amperage, see Section 5-9.
1
3
Wire Speed Control
Use control to adjust wire speed within the speed
range selected by the wire speed range switch,
located on the inner control panel. Maximum
wire speed may be limited by arc voltage.
2
When using wire speed dual schedule, the reduced wire speed will be 87.5% of the standard
wire speed− See Section 6-3.
4
3
Trigger Hold Switch
Trigger hold allows operator to weld without holding gun trigger.
To use trigger hold function, place trigger hold
switch in the ON position.
4
6
5
The operator must hold the trigger for a minimum
of 2 seconds, but no longer than 6 seconds before releasing it. Welding will continue when trigger is released.
To stop welding, press and release the trigger.
5
Jog/Purge Switch
Pressing the Jog switch allows the operator to
jog wire without energizing the contactor or gas
valve.
Pressing the Purge switch allows the operator to
purge gas lines before welding and to preset gas
flow rate at the flowmeter.
9
6
7
7
8
Use switch to select speed range. High range is
100 to 800 Inches per Minute (2.5 to 20.3 Meters
per Minute). Low range is 25 to 200 Inches per
Minute (0.6 to 5.1 Meters per Minute).
8
Internal Control Panel
Power Control Switch
HI/LO Speed Range Switch
CC/CV Switch
Use switch to match feeder with the output of the
power source.
While welding in CC mode, actual wire speed is
dependent on arc voltage.
While welding in CV mode, the wire feeder remains at constant speed and the wire speed is
not dependent on arc voltage. Maximum wire
speed may be limited by arc voltage.
9
Internal Side View
Soft Start Switch
The Soft Start feature provides a smooth start
during most weld conditions. When the trigger is
pulled, the wire speed is approximately 50% of
the weld wire speed, as set by the wire speed
control knob. After an arc is established, the wire
speed increases to the weld wire speed.
When using small diameters wire, or with inverter power sources, it may be necessary to turn
soft start off to obtain smooth starts.
After adjusting the switches, close and latch the
door before welding.
Ref. 265 368-B / 262 370-B
OM-262379 Page 19
6-2. Controls Without Meters
1
Wire Speed Control
Use control to adjust wire speed within the
speed range selected by the wire speed
range switch, located on the inner control
panel. Maximum wire speed may be limited
by arc voltage.
When using wire speed dual schedule, the
reduced wire speed will be 87.5% of the
standard wire speed− See Section 6-3.
2
3
Power Control Switch
Jog/Purge Switch
Pressing the Jog switch allows the operator
to jog wire without energizing the contactor
or gas valve.
1
Pressing the Purge switch allows the operator to purge gas lines before welding and to
preset gas flow rate at the flowmeter.
4
Trigger Hold Switch
Trigger hold allows operator to weld without
holding gun trigger.
To use trigger hold function, place trigger
hold switch in the ON position.
4
2
3
The operator must hold the trigger for a minimum of 2 seconds, but no longer than 6 seconds before releasing it. Welding will continue when trigger is released.
To stop welding, press and release the trigger.
5
CC/CV Switch
Use switch to match feeder with the output of
the power source.
7
6
5
While welding in CC mode, actual wire speed
is dependent on arc voltage.
While welding in CV mode, the wire feeder
remains at constant speed and the wire
speed is not dependent on arc voltage. Maximum wire speed may be limited by arc
voltage.
6
HI/LO Speed Range Switch
Use switch to select speed range. High
range is 100 to 800 Inches per Minute (2.5 to
20.3 Meters per Minute). Low range is 25 to
200 Inches per Minute (0.6 to 5.1 Meters per
Minute).
Internal Control Panel
7
Soft Start Switch
The Soft Start feature provides a smooth
start during most weld conditions. When the
trigger is pulled, the wire speed is approximately 50% of the weld wire speed, as set by
the wire speed control knob. After an arc is
established, the wire speed increases to the
weld wire speed.
Internal Side View
When using small diameters wire, or with inverter power sources, it may be necessary to
turn soft start off to obtain smooth starts.
After adjusting the switches, close and latch
the door before welding.
Ref. 265 368-B / 261 915-B
OM-262379 Page 20
6-3. Wire Speed Dual Schedule
Wire Speed Dual Schedule allows the operator to switch between standard wire speed
and a reduced wire speed. When activated,
the reduced wire speed will be 87.5% of the
standard wire speed. Wire Speed Dual
Schedule may be activated any time before
or during the weld by using a gun with an internally mounted dual schedule switch, or a
gun with an added dual schedule switch. If
the feeder is equipped with Wire Speed
Meter it will display the active wire speed,
whether it is standard wire speed or reduced
wire speed.
Weld Gun With Internal Mounted
Dual Schedule Switch
Weld Gun With Internal Mounted Dual
Schedule Switch Comparable To
PipePro Dura−Flux Gun.
1
2
Gun Trigger Receptacle
Gun Trigger Plug
Connect gun trigger plug to gun trigger
receptacle.
1
2
Weld Gun With External Mounted Dual
Schedule Switch Comparable To
DSS−9−15 (071833)
3
4
5
6
Connect gun trigger plug to dual schedule
switch receptacle . Connect dual schedule
plug to gun trigger receptacle.
Weld Gun With External Mounted
Dual Schedule Switch
3
Gun Trigger Receptacle
Dual Schedule Plug
Dual Schedule Switch Receptacle
Gun Trigger Plug
4
5
6
265 376-A / 265 377-A
OM-262379 Page 21
6-4. Wire Speed Control Settings
Ref. 257 488-A
Notes
OM-262379 Page 22
SECTION 7 − MAINTENANCE & TROUBLESHOOTING
7-1. Routine Maintenance
!
= Check
= Change
Every
3
Months
= Clean
Maintain more
Disconnect power
before maintaining.
often during
severe conditions.
= Replace
Replace
Damaged
Or
Unreadable
Labels
Replace
Damaged Gas
Hose
Repair Or Replace
Cracked Cables And
Cords
Every
6
Months
Clean
Drive
Rolls
Blow Out Or
Vacuum Inside
7-2. Overload Protection And Thermostat Protection
1
!
Turn Off wire feeder and
welding power source. Stop
engine on welding
generator.
1
Supplementary Protector CB1
CB1 protects wire feeder from overload. Correct problem and reset
CB1.
Close and latch door.
Thermostat Protection
Unit has internal thermostat protection and will not feed wire if overheating occurs (see Section 7-4).
CB1
Internal Side View
Ref. 265 368-B
OM-262379 Page 23
7-3. Cleaning Debris From Shielding Gas Filter Fitting
!
Disconnect power
maintaining.
1
Shielding Gas Filter Fitting
before
Remove fitting from gas valve on
back panel of feeder.
Blow compressed air through the
threaded male end of fitting to dislodge debris from internal mesh
screen.
if blowing compressed air
through fitting does not clear
obstructions replace fitting.
Rear View of Feeder
Reinstall fitting into gas valve.
Tighten fitting to 250 in. lbs (28 N⋅m).
1
Tools Needed:
3/4 in.
OM-262379 Page 24
265 373-A
7-4. Troubleshooting
Trouble
Remedy
Wire does not feed; open-circuit voltage Check power switch S1 and connections, and replace if necessary.
available.
Check supplementary protector CB1. Reset CB1.
Unit overheated. Allow unit to cool.
Check sensing lead connection.
Check gun trigger plug connection.
Check gun trigger. See gun Owner’s Manual.
Have Factory Authorized Service Agent check Motor Control Board (PC1).
Wire feeds erratically.
Readjust hub tension (see Section 5-7).
Readjust drive roll pressure (see Section 5-7).
Clean or replace dirty or worn drive roll (see Section 5-2).
Remove weld spatter around gun nozzle opening.
Replace contact tip or liner. See gun Owner’s Manual.
Change to correct size and type drive roll (see Section 5-2)
Check that DIP switches on Motor Control Board (PC1) are set correctly (see Section 5-8)
Have Factory Authorized Service Agent check Motor Control Board (PC1).
Motor runs slowly.
When soft start is on, motor will run slow until weld current is sensed by HD1.
Readjust hub tension (see Section 5-7).
Check if wire speed dual schedule switch is activated (if applicable, See Section 6-3)
Check and replace contact tip or liner if necessary. See gun Owner’s Manual
Check that DIP switches on Motor Control Board (PC1) are set correctly (see Section 5-8)
Have Factory Authorized Service Agent check Motor Control Board (PC1).
Unit does not switch out of Soft Start.
Check transducer HD1 and connections, and replace if necessary.
Wire feeds when Jog switch is pressed Check gun trigger connection at wire feeder. Check gun trigger leads and trigger switch. See gun Owner’s
but not when gun trigger is pressed.
Manual.
Have Factory Authorized Service Agent check Motor Control Board (PC1).
Wire stubbing on low end using a con- Make sure CC/CV switch is in CC position (see Section 6-1 or 6-2).
stant current power source or feeder
resets.
Increase power source inductance setting if available.
Increase output setting of power source or decrease wire feed speed.
Gas does not flow or does not stop
flowing; wire feeds.
Clear blockage in gas hose or replace hose.
Clear blockage in welding gun.
Clear blockage in filter (see Section 7-3).
Check gas valve.
Check coil voltage and connections of gas valve GS1. Check continuity of coil. Replace GS1 if necessary.
Have Factory Authorized Service Agent check Motor Control Board (PC1).
Wire remains energized after trigger is Check setting of trigger hold switch, if applicable.
released.
Check contactor W1 to see if contacts are frozen closed.
OM-262379 Page 25
Trouble
Remedy
Gun trigger is pressed, gas does not If a welding arc is not established in 3 seconds, after the gun trigger is activated, the unit will feed wire
flow, wire is not energized, wire feeds.
without energizing the contactor or gas valve. The unit will feed approximately 35 feet (10.7 meters) of
wire, then stop feeding. This is to prevent complete de-spooling of the wire, as in the case of a damaged
gun.
Display on meter board PC20 does not Have Factory Authorized Service Agent check Motor Control Board (PC1).
light.
Replace meter board PC20.
Segments on the meter board PC20 are Replace meter board PC20.
missing.
Arc voltage on meter board PC20 is not Arc voltage on the meter board PC20 will show weld voltage at the feeder. Due to voltage drops in the
weld cables, arc voltage at the feeder will not match arc voltage at the welding power source. Due to averaccurate.
aging of arc voltage, if weld time is less than 8 seconds the displayed arc voltage at the feeder may not
be accurate.
Check Motor Control (PC1) and connections, replace if necessary.
Weld amperage on meter board PC20 is Amperage displayed at feeder is approximate. Refer to power source for actual amperage
(see Section 5-9).
not accurate.
Check DIP switch settings on meter board PC20 (see Section 5-9).
Check transducer HD1 and connections, and replace if necessary.
Check Motor Control (PC1) and connections, replace if necessary.
Software and weld time information on Check DIP switch settings on meter board PC20 (see Section 5-9).
meter board PC20 is not accurate.
Check Motor Control (PC1) and connections, replace if necessary.
7-5. Diagnostics
Error Indicators
Shown On (Optional) Display
RED LED on Motor Control Board (PC1)
Error
HLP 11
1 Blink
Communication Error
HLP 12
2 Blinks
Trigger Error
HLP 13
3 Blinks
Tach Error
HLP 14
4 Blinks
Motor
Overload Error
HLP 15
5 Blinks
Bus Bar
Overheat Error
Error Indications - Error conditions are indicated by a “HLP” message on the display, or by the blinking of the Red LED on Motor Control Board
(PC1). To view the Red LED, turn Off power source, remove shroud, and turn power source On. The number of blinks in this period indicates the
type of error. If an error condition does not exist on the Motor Control Board (PC1), the Red LED is on steady.
Communication Error - The communication error occurs 2.5 seconds after a loss of communication between the Motor Control Board (PC1) and
the meter board PC20. The user may continue to weld with this error. The error may be cleared by turning power Off, waiting a minimum of two
seconds, and turning power On.
Trigger Error - The trigger error occurs if the user has fed approximately 35 feet (10.7 meters) of wire without striking an arc. The error may be
cleared by releasing the trigger.
Motor Overload Error - The motor overload error can indicate that the motor has been drawing too much current for too long, To remedy this,
reduce the wire feed speed or the wire feeder torque load/duty cycle. The error may be cleared by turning power Off, waiting a minimum of two
seconds, and turning power On.
Bus Bar Overheat Error - The bus bar overheat error can be caused by the arc drawing too much current for too long. To remedy this, reduce
the weld amperage or duty cycle.
Tach Error - May indicate motor is overloaded. If a tach error occurs, feeder will continue to function. When the trigger is released, a tach error
will be indicated on the front panel, or red LED blinks on Motor Control Board (PC1). The tach error will be cleared when the feeder is re-triggered.
If error persists, have feeder serviced. Tach error may also be generated if DIP switch SW1 on Motor Control Board (PC1) is set incorrectly (see
Section 5-8).
OM-262379 Page 26
SECTION 8 − ELECTRICAL DIAGRAM
252200-E
Figure 8-1. Circuit Diagram For Wire Feeder
OM-262379 Page 27
SECTION 9 − PARTS LIST
5
4
1
2
25
16
14
34
20
21
22
19
17
12
18
8
13
28
46
11
7
6
12
9
26
27
10
29
13
30
15
33
32
45
44
40
28
31
47
41
43
36 42
37
38
24
23
13
3
39
35
265735-D
Figure 9-1. Complete Assembly
OM-262379 Page 28
Item
No.
Diagram
marking
Part
No.
Description
Figure 9-1. Complete Assembly
Quantity
1 . . . . . . . . . . . . . . . . . . . Fig 9-2 . . Panel Assembly Front (Without Meters) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2 . . . . . . . . . . . . . . . . . . Fig 9-3 . . Panel Assembly Front (With Meters) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
3 . . . . . . . . . . . . . . . . . . Fig 9-4 . . Drive Assembly, Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
4 . . . . . . . . . . . . . . . . . . 276979 . . Case, Feeder (Service) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
5 . . . . . . . . . . . . . . . . . . 208015 . . Handle, Rubberized Carrying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
6 . . . . . . . . CB1 . . . . . 083432 . . Supplementary Pro, Man Reset 1P 10A 250VAC Frict . . . . . . . . . . . . . . . . 1
7 . . . . . . . . . . . . . . . . . . 255703 . . Panel, Inner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
8 . . . . . . . . . . . . . . . . . . 256203 . . Nameplate, Inner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
9 . . . . . S3, S5, S6 . . 217932 . . Switch, Rocker Spst .4VA 28VDC On-None-Off .187 Ter . . . . . . . . . . . . . . 3
10 . . . . . . . . . . . . . . . . . 147195 . . Nut, 375-27 .54Hex .25H Nyl Flange .62D . . . . . . . . . . . . . . . . . . . . . . . . . . 1
11 . . . . . . . . . . . . . . . . . 261917 . . Chassis, Control Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
12 . . . . . . . . . . . . . . . . . 256594 . . Grommet, Scr No 8/10 Panel Hole .309X.315 .125H . . . . . . . . . . . . . . . . . 2
13 . . . . . . . . . . . . . . . . . 256595 . . Grommet, Scr No 8/10 Panel Hole .270X.290 .062H . . . . . . . . . . . . . . . . . 5
14 . . . . . . . . . . . . . . . . . 244548 . . Spindle, Support Spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
15 . . . . . . . . . . . . . . . . . 258340 . . Clip, Snap In .250 Hole .062−.857 Pnl Thk Blk . . . . . . . . . . . . . . . . . . . . . . . 1
16 . . . . . . . . . . . . . . . . . 262367 . . Shroud, Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
17 . . . . . . . . . . . . . . . . . 235607 . . Nut, Hub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
18 . . . . . . . . . . . . . . . . . 237843 . . Knob, Brake Adjust . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
19 . . . . . . . . . . . . . . . . . 172918 . . Spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
20 . . . . . . . . . . . . . . . . . 231211 . . Washer, Anti-Turn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
21 . . . . . . . . . . . . . . . . . 235609 . . Hub, Spool 8 Inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
22 . . . . . . . . . . . . . . . . . 058424 . . Washer, Fiber (Brake) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
23 . . . . . . . . . . . . . . . . . 087111 . . Clamp, Capacitor 1.375 Dia Clip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
24 . . . . . . . C1 . . . . . . 200606 . . Capacitor, Elctlt 1200 Uf 300 VDC Can 1.39 Dia . . . . . . . . . . . . . . . . . . . . . 1
25 . . . . . . . . . . . . . . . . . 244552 . . Bracket, Spool Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
26 . . . . . . . . . . . . . . . . . 211989 . . Fitting, W/Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
27 . . . . . . . . . . . . . . . . . 139041 . . Bushing, Strain Relief .450/.709 Id X1.115 Mtg Hole . . . . . . . . . . . . . . . . . . 1
28 . . . . . . . . . . . . . . . . . 200627 . . Weld Cable Assembly, 2/0 (Includes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . 600322 . . . . Cable, Weld Cop Strd No 2/0 Ep Rubber Jacket 600V . . . . . . . . . . . . 20 in.
. . . . . . . . . . . . . . . . . . . . 600732 . . . . Term, Ring Tng 375/10mm Stud Solistrand . . . . . . . . . . . . . . . . . . . . . . . . 1
29 . . . . . . . . . . . . . . . . . 262398 . . Insulator, Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
30 . . . . . . . . . . . . . . . . . 264929 . . Bushing Gas Valve Opening . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
31 . . . . . . . . . . . . . . . . . 254843 . . Nut, PG21 1.50Hex X .375H Aluminum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
32 . . . . . . . . . . . . . . . . . 253430 . . Terminal, Connector Friction 0.406 Id . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
33 . . . . . . . PC1 . . . . . 238276 . . Circuit Card Assy, Motor Control Board W/Program . . . . . . . . . . . . . . . . . . 1
34 . . . . . . . . . . . . . . . . . 175969 . . Insulator, PC Card Self Adhesive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
35 . . . . . . . . . . . . . . . . . 183387 . . Washer, Cone .380idx .860odx.109T Stl Pld 4000Lbs . . . . . . . . . . . . . . . . 2
36 . . . . . . . W1 . . . . . 261918 . . Contactor Assembly, (Includes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG5 . . . . 201665 . . . . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
37 . . . . . . . . . . . . . . . . . 183387 . . . . Washer, Cone .380idx .860odx.109T Stl Pld 4000Lbs . . . . . . . . . . . . . . . 2
38 . . . . . . . . . . . . . . . . . 232295 . . . . Nut, M10−1.5 17Hex 10H Stl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
39 . . . . TP1, TP2 . . . 230471 . . . . Thermostat, Nc Open 140C Close 110C Snap Action . . . . . . . . . . . . . . . 2
40 . . . . . . . . . . . . . . . . . 261921 . . . . Bracket, Mtg Contactor/Spool Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
41 . . . . . . . . . . . . . . . . . 134834 . . Hose, SAE .187 Id X .410 Od X Coil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 in.
42 . . . . . . . . . . . . . . . . . 149332 . . Clamp, Hose .405 − .485 Clp Dia Slfttng Olive Dra . . . . . . . . . . . . . . . . . . . 2
43 . . . . . . . GS1 . . . . . 226819 . . Valve, 12VDC 1Way .750−14 Thd 2mm Orf 100PSI . . . . . . . . . . . . . . . . . . 1
44 . . . . . . . . . . . . . . . . . 263842 . . Bracket, Gas Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
45 . . . . . . . . . . . . . . . . . 220805 . . Nut, 750-14 Knurled 1.68Dia .41H Nyl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . 252367 . . Label, Warn Gen Precaution Suitcase CE/Domestic . . . . . . . . . . . . . . . . . . 2
. . . . . . . . . . . . . . . . . . . . 261688 . . Label, Warning Electric Shock And Pinch Wordless . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . 230361 . . Label, Warning X−TREME 8VS Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG3 . . . . 115093 . . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG4 . . . . 131054 . . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG5 . . . . 201665 . . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG7 . . . . 130203 . . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG8 . . . . 115091 . . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . PLG10 . . . . 131052 . . Housing Rcpt+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . PLG17 . . . . 222397 . . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . PLG9, 21 . . . 131055 . . Housing Rcpt+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . . . . . PLG22 . . . . 115092 . . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . PLG111 . . . 256953 . . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
46 . . . . . . . . . . . . . . . . . 268286 . . Conn, TW LK Insul Male (Tweco/Lenco Type) LC-40 HD 2/0 . . . . . . . . . . 1
47 . . . . . . . . . . . . . . . . . 025248 . . Stand−Off, Insul .250−20 X 1.250 Lg X .437 Thd . . . . . . . . . . . . . . . . . . . . 1
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-262379 Page 29
Hardware is common and
2
not available unless listed.
1
3
5
4
8
7
10
6
9
265375-A
Figure 9-2. Front Panel Assembly without Meters
Item
No.
Dia.
Mkgs
.
Part
No.
Description
Quantity
Figure 9-2. Front Panel Assembly without Meters (Figure 9-1 Item 1)
. . 1 . . . . . . . . . . . . . . . . . . . . . . . . Nameplate, Without Meters (Order By Model And Serial Number) . . . . . . . 1
. . 2 . . . . . . . . . . . . . . 261914 . . Panel, Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 3 . . . . . R1 . . . . . 208399 . . Pot, Cp Std Slot 1T 2. W 10K Linear W/Fricttabs . . . . . . . . . . . . . . . . . . . . . . 1
. . 4 . . . . . . . . . . . . . . 171007 . . Knob, Pointer 1.670 Dia X .250 Id W/Set Screwsplstc . . . . . . . . . . . . . . . . . . 1
. . 5 . . . . . . . . . . . . . . 604645 . . Nut, 375−32 .56Hex .09H Stl Pld Use W/Pots . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 6 . . . . . S2 . . . . . 266614 . . Switch, Rocker SPDT 8A 125VAC (On)−Off−(On) .187T . . . . . . . . . . . . . . . 1
. . 7 . . . . . S4 . . . . . 217932 . . Switch, Rocker SPST .4VA 28VDC On−None−Off .187T . . . . . . . . . . . . . . . 1
. . 8 . . . . . S1 . . . . . 267296 . . Switch, Rocker SPST 15A 250VAC On−Off Visi Red Rock . . . . . . . . . . . . . 1
. . 9 . . . . . . . . . . . . . . 252262 . . Cable, Trigger 25in W/Strain Relief (Includes) . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . 139042 . . . . Bushing, Strain Relief .270/.470 Id X .804 Mtg Hole . . . . . . . . . . . . . . . . . . 1
. . . . . . . . PLG6 . . . . 115094 . . . . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . 079531 . . . . Conn, Circ CPC Clamp Str Rlf Size 11 .453OD . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . RC2 . . . . . 080328 . . . . Rcpt W/Skts, Free Hanging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . 604571 . . . . Cable, Port NO 18 4/C Type Sjo Nprn Jkt Re . . . . . . . . . . . . . . . . . . . . . 25 in.
. . 10 . . . . . . . . . . . . . 252212 . . Cable, Sensing W/Strain Relief (Includes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . 139042 . . . . Bushing, Strain Relief .270/.470 Id X .804 Mtg Hole . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . 208820 . . . . Clamp, Work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . 258058 . . . . Wire, Strd 10Ga Blk 600V 125C 105x30 Poe .216od . . . . . . . . . . . . . . . . 16 Ft
. . . . . . . . . . . . . . . . . . . 261163 . . . . Label, Warning Electric Shock/Volt Sense Clamp . . . . . . . . . . . . . . . . . . . . 1
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-262379 Page 30
Hardware is common and
not available unless listed.
2
3
1
5
4
8
6
7
10
9
265374-A
Figure 9-3. Front Panel Assembly with Meters
Item
No.
Dia.
Mkgs
.
Part
No.
Description
Quantity
Figure 9-3. Front Panel Assembly with Meters (Figure 9-1 Item 2)
. . 1 . . . . . . . . . . . . . . . . . . . . . . . . Nameplate, With Meters (Order By Model And Serial Number) . . . . . . . . . . 1
. . 2 . . . . . . . . . . . . . . 261914 . . Panel, Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 3 . . . PC20 . . . . 258989 . . Circuit Card Assy, Meter Suitcase w/Program . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 4 . . . . . . . . . . . . . . 174991 . . Knob, Pointer 1.250 Dia X .250 ID W/Spring Clip−.21 . . . . . . . . . . . . . . . . . . 1
. . 5 . . . . . . . . . . . . . . 604645 . . Nut, 375−32 .56Hex .09H Stl Pld Use W/Pots . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 6 . . . . . S2 . . . . . 266614 . . Switch, Rocker SPDT 8A 125VAC (On)−Off−(On) .187T . . . . . . . . . . . . . . . 1
. . 7 . . . . . S4 . . . . . 217932 . . Switch, Rocker SPST .4VA 28VDC On−None−Off .187 Ter . . . . . . . . . . . . . 1
. . 8 . . . . . S1 . . . . . 267296 . . Switch, Rocker SPST 15A 250VAC On−Off Visi Red Rock . . . . . . . . . . . . . 1
. . 9 . . . . . . . . . . . . . . 252262 . . Cable, Trigger 25in W/Strain Relief (Includes) . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . 139042 . . . . Bushing, Strain Relief .270/.470 Id X .804 Mtg Hole . . . . . . . . . . . . . . . . . . 1
. . . . . . . . PLG6 . . . . 115094 . . . . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . 079531 . . . . . . Conn, Circ CPC Clamp Str Rlf Size 11 .453OD . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . RC2 . . . . . 080328 . . . . Rcpt W/Skts, Free Hanging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . 604571 . . . . Cable, Port NO 18 4/C Type Sjo Nprn Jkt Re . . . . . . . . . . . . . . . . . . . . . 25 in.
. . 10 . . . . . . . . . . . . . 252212 . . Cable, Sensing W/Strain Relief (Includes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . 139042 . . . . Bushing, Strain Relief .270/.470 Id X .804 Mtg Hole . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . 208820 . . . . Clamp, Work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . 258058 . . . . Wire, Strd 10Ga Blk 600V 125C 105x30 Poe .216od . . . . . . . . . . . . . . . . 16 Ft
. . . . . . . . . . . . . . . . . . . 261163 . . . . Label, Warning Electric Shock/Volt Sense Clamp . . . . . . . . . . . . . . . . . . . . 1
To Maintain The Factory Original Performance Of Your Equipment, Use Only Manufacturer’S Suggested
Replacement Parts. Model And Serial Number Required When Ordering Parts From Your Local Distributor.
OM-262379 Page 31
Hardware is common and
not available unless listed.
1
2
15
16
11
3
10
17
9
18
12
13
5
14
4
19
8
10
21
27
22
26
20
32
33
31
30
29
7
6
24
42
36
13
25
45
23
40
34
44
35
39
38
41
43
37
46
28
257016-B
Figure 9-4. Drive Assembly, Wire
OM-262379 Page 32
Item
No.
Dia.
Mkgs
.
Part
No.
Description
Quantity
Figure 9-4. Drive Assembly, Wire (Figure 9-1 Item 3)
1 . . . . . . . . M1 . . . . .
2 . . . . . . . PLG4 . . . .
3 ..................
4 ..................
5 ..................
6 ..................
7 ..................
8 ..................
....................
9 ..................
10 . . . . . . . . . . . . . . . . .
11 . . . . . . . . . . . . . . . . .
12 . . . . . . . . . . . . . . . . .
13 . . . . . . . . . . . . . . . . .
14 . . . . . . . . . . . . . . . . .
15 . . . . . . . . . . . . . . . . .
16 . . . . . . . . . . . . . . . . .
17 . . . . . . . . . . . . . . . . .
18 . . . . . . . . . . . . . . . . .
19 . . . . . . . . . . . . . . . . .
20 . . . . . . . . . . . . . . . . .
21 . . . . . . . . . . . . . . . . .
22 . . . . . . . . . . . . . . . . .
23 . . . . . . . . . . . . . . . . .
24 . . . . . . . . . . . . . . . . .
25 . . . . . . . . . . . . . . . . .
26 . . . . . . . . . . . . . . . . .
27 . . . . . . . . . . . . . . . . .
28 . . . . . . . . . . . . . . . . .
....................
....................
....................
....................
29 . . . . . . . . . . . . . . . . .
30 . . . . . . . . . . . . . . . . .
31 . . . . . . . . . . . . . . . . .
32 . . . . . . . . . . . . . . . . .
33 . . . . . . . . . . . . . . . . .
34 . . . . . . . . . . . . . . . . .
35 . . . . . . . . . . . . . . . . .
36 . . . . . . . . . . . . . . . . .
37 . . . . . . . . . . . . . . . . .
38 . . . . . . . . . . . . . . . . .
39 . . . . . . . . . . . . . . . . .
40 . . . . . . . . . . . . . . . . .
41 . . . . . . . . . . . . . . . . .
42 . . . . . . . . . . . . . . . . .
43 . . . . . . . . . . . . . . . . .
44 . . . . . . . . . . . . . . . . .
45 . . . . . . . . . . . . . . . . .
46 . . . . . . . . . . . . . . . . .
252214
131054
252229
149332
134834
263858
231181
174610
256035
079634
151828
252235
252238
172075
228562
196895
252243
241856
085244
267899
010224
222159
253655
253513
166072
273794
264611
144172
263877
259857
231223
183387
252232
252230
252786
252220
602237
174609
133308
168825
252222
124778
237188
278295
234073
151828
252785
258838
604432
252322
252323
. . Motor, Right Angle 24VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Housing Plug+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Insulator, Motor/Drive/Tach . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Clamp, Hose .405 − .485 Clp Dia Slfttng Olive Dra . . . . . . . . . . . . . . . . . . . 1
. . Hose, SAE .187 Id X .410 Od Xcoil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 In.
. . Module, Tach Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Screw, 004−40x .37 Soc Hd−Hex Stl Pld . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . Screw, M 6−1.0x 20 Soc Hd Button Cap Blk . . . . . . . . . . . . . . . . . . . . . . . . . 3
. . Casting Assembly, Drive (Includes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Pin, Hinge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Pin, Cotter Hair .042 X .750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
. . . . Lever, Mtg Pressure Gear Machined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Stand−Off, Drive Roll Carrier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Carrier, Drive Roll W/Components 24 Pitch . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . Screw, 006−32x .25 Pan Hd−Phl W/Ext Washer (Sems) Stl . . . . . . . . . 1
. . . . Knob, Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Spring, Cprsn Big . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Cup, Spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Washer, Cupped .328idx .812odx16gax.125 Lip . . . . . . . . . . . . . . . . . . . . 1
. . . . Fastener, Pinned Machined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Pin, Spring Cs .187 X 1.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Spring, Torsion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Insulator, Screw Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
. . . . Housing, Wire Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Spacer, Gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Screw, 250−20x1.38 Soc Hd−Hex Gr8 Pln . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . O−Ring, .187 Id X .312 Od X .063 Cs 75 Duro Fluor . . . . . . . . . . . . . . . . 1
. . . . Ftg, Hose Brs Barbed M 3/16 TBG X .250-20 . . . . . . . . . . . . . . . . . . . . . . 1
. . . . Wire Drive Bus Bar (Service Kit) (Includes) . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . Screw, 375−16X .87 Hex Hd−Pln Gr5 Pld Blk . . . . . . . . . . . . . . . . . . . . 1
. . . . . . Nut, 375−16 .56Hex .34H Stl Pld Clr . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . Washer, Cone .380idx .860odx.109T Stl Pld 4000lbs . . . . . . . . . . . . . . 2
. . . . . . Bolt, Crg Stl .375−16 X 1.000 Gr5 Pl Fnsh . . . . . . . . . . . . . . . . . . . . . . . 1
. . Grommet, Motor Shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Drive, Pinion 10mm Shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Key, Stl 3mm/3mm X 10mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Washer, Flat .172idx0.500od X .048t Stl Pld Blk . . . . . . . . . . . . . . . . . . . . . 1
. . Screw, M 4− .7x 12 Cheese Hd Blk Din 84 . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Ring, Rtng Ext .375 Shaft X .025 Thk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Drive, Pinion Sntr 22T 24P .376 Bore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Screw, 010−32x .75 Soc Hd−Hex Stl Gr8 Pld Lkg Patch . . . . . . . . . . . . . . 4
. . Knob, T 2.000 Bar W/.312-18 Stud 1.000 Lg Plstc . . . . . . . . . . . . . . . . . . . 1
. . Lock, Pin Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Clamp, Power Pin Cast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Pin, Hinge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Pin, Cotter Hair .042 X .750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
. . Cover, Gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Screw, 008−32x .37 Pan Hd−Phl Stl Pld Zc Lkg Patch . . . . . . . . . . . . . . . . 3
. . Screw, 008−32x 1.00 Soc Hd−Hex Gr8 Pln . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Block, Wire Inlet Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . Pin, Wire Inlet Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
To Maintain The Factory Original Performance Of Your Equipment, Use Only Manufacturer’S Suggested
Replacement Parts. Model And Serial Number Required When Ordering Parts From Your Local Distributor.
OM-262379 Page 33
Table 9-1. Drive Roll Guide
Base Selection Of Drive Rolls Upon The Following Recommended Usages:
1.
2.
3.
4.
5.
V-Grooved Rolls For Hard Wire.
U-Grooved Rolls For Soft And Soft Shelled Cored Wires.
U-Cogged Rolls For Extremely Soft Shelled Wires (Usually Hard Surfacing Types).
V-Knurled Rolls For Hard Shelled Cored Wires.
Drive Roll Types May Be Mixed To Suit Particular Requirements (Example: V-Knurled Roll In Combination With U-Grooved).
Fraction
Wire Diameter
Decimal
Metric
Drive Roll (2 Required)
Part No.
Type
.023/.025 in.
.023/.025 in.
0.6 mm
087130
V-Grooved
.030 in.
.030 in.
0.8 mm
053695
V-Grooved
.035 in.
.035 in.
0.9 mm
053700
V-Grooved
.040 in.
.040 in.
1.0 mm
053696
V-Grooved
.045 in.
.045 in.
1.2 mm
053697
V-Grooved
.052 in.
.052 in.
1.3 mm
053698
V-Grooved
1/16 in.
.062 in.
1.6 mm
053699
V-Grooved
.035 in.
.035 in.
0.9 mm
072000
U-Grooved
.045 in.
.045 in.
1.2 mm
053701
U-Grooved
.052 in.
.052 in.
1.3 mm
053702
U-Grooved
1/16 in.
.062 in.
1.6 mm
053706
U-Grooved
5/64 in.
.079 in.
2.0 mm
053704
U-Grooved
.035 in.
.035 in.
0.9 mm
132958
V-Knurled
.045 in.
.045 in.
1.2 mm
132957
V-Knurled
.052 in.
.052 in.
1.3 mm
132956
V-Knurled
1/16 in.
.062 in.
1.6 mm
132955
.068-.072 in.
.068-.072 in.
1.8 mm
132959
V-Knurled
V-Knurled
5/64 in.
.079 in.
2.0 mm
132960
V-Knurled
.045 in.
.045 in.
1.2 mm
083489
U-Cogged
.052 in.
.052 in.
1.3 mm
083490
U-Cogged
1/16 in.
.062 in.
1.6 mm
053708
U-Cogged
5/64 in.
.079 in.
2.0 mm
053710
U-Cogged
S-0859
OM-262379 Page 34
Effective January 1, 2018
(Equipment with a serial number preface of MJ or newer)
Warranty Questions?
Call
1-800-4-A-MILLER
for your local
Miller distributor.
Your distributor also gives
you ...
Service
You always get the fast,
reliable response you
need. Most replacement
parts can be in your
hands in 24 hours.
Support
Need fast answers to the
tough welding questions?
Contact your distributor.
The expertise of the
distributor and Miller is
there to help you, every
step of the way.
This limited warranty supersedes all previous Miller warranties and is exclusive with no other
guarantees or warranties expressed or implied.
LIMITED WARRANTY − Subject to the terms and conditions below, 5. 6 Months — Parts
Miller Electric Mfg. LLC, Appleton, Wisconsin, warrants to its original
* Batteries
retail purchaser that new Miller equipment sold after the effective date of 6. 90 Days — Parts
this limited warranty is free of defects in material and workmanship at
* Accessory (Kits)
the time it is shipped by Miller. THIS WARRANTY IS EXPRESSLY IN
* Canvas Covers
LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,
* Induction Heating Coils and Blankets, Cables, and
INCLUDING THE WARRANTIES OF MERCHANTABILITY AND
Non-Electronic Controls
FITNESS.
* M-Guns
Within the warranty periods listed below, Miller will repair or replace any
warranted parts or components that fail due to such defects in material
* MIG Guns, Subarc (SAW) Torches, and External
or workmanship. Miller must be notified in writing within thirty (30) days
Cladding Heads
of such defect or failure, at which time Miller will provide instructions on
* Remote Controls and RFCS-RJ45
the warranty claim procedures to be followed. If notification is submitted
* Replacement Parts (No labor)
as an online warranty claim, the claim must include a detailed
* Spoolmate Spoolguns
description of the fault and the troubleshooting steps taken to identify
failed components and the cause of their failure.
Miller shall honor warranty claims on warranted equipment listed below
in the event of such a failure within the warranty time periods. All
warranty time periods start on the delivery date of the equipment to the
original end-user purchaser, and not to exceed twelve months after the
equipment is shipped to a North American distributor or eighteen
months after the equipment is shipped to an International distributor.
1.
2.
3.
4.
5 Years Parts — 3 Years Labor
* Original Main Power Rectifiers Only to Include SCRs,
Diodes, and Discrete Rectifier Modules
3 Years — Parts and Labor
* Auto-Darkening Helmet Lenses (Except Classic
Series) (No Labor)
* Engine Driven Welder/Generators
(NOTE: Engines are Warranted Separately by the
Engine Manufacturer.)
* Inverter Power Sources
* Plasma Arc Cutting Power Sources
* Process Controllers
* Semi-Automatic and Automatic Wire Feeders
* Transformer/Rectifier Power Sources
2 Years — Parts and Labor
* Auto-Darkening Helmet Lenses − Classic Series Only
(No Labor)
* Auto-Darkening Weld Masks (No Labor)
* Fume Extractors − Capture 5, Filtair 400 and Industrial
Collector Series
1 Year — Parts and Labor Unless Specified
* AugmentedArc and LiveArc Welding Systems
* Automatic Motion Devices
* Bernard BTB Air-Cooled MIG Guns (No Labor)
* CoolBelt and CoolBand Blower Unit (No Labor)
* Desiccant Air Dryer System
* External Monitoring Equipment and Sensors
* Field Options
(NOTE: Field options are covered for the remaining
warranty period of the product they are installed in,
or for a minimum of one year — whichever is
greater.)
* RFCS Foot Controls (Except RFCS-RJ45)
* Fume Extractors − Filtair 130, MWX and SWX Series
* HF Units
* ICE/XT Plasma Cutting Torches (No Labor)
* Induction Heating Power Sources, Coolers
(NOTE: Digital Recorders are Warranted
Separately by the Manufacturer.)
* Load Banks
* Motor-Driven Guns (except Spoolmate Spoolguns)
* PAPR Blower Unit (No Labor)
* Positioners and Controllers
* Racks
* Running Gear/Trailers
* Spot Welders
* Subarc Wire Drive Assemblies
* TIG Torches (No Labor)
* Tregaskiss Guns (No Labor)
* Water Cooling Systems
* Wireless Remote Foot/Hand Controls and Receivers
* Work Stations/Weld Tables (No Labor)
Miller’s True Blue® Limited Warranty shall not apply to:
1.
2.
3.
Consumable components; such as contact tips,
cutting nozzles, contactors, brushes, relays, work
station table tops and welding curtains, or parts that
fail due to normal wear. (Exception: brushes and
relays are covered on all engine-driven products.)
Items furnished by Miller, but manufactured by others,
such as engines or trade accessories. These items are
covered by the manufacturer’s warranty, if any.
Equipment that has been modified by any party other than
Miller, or equipment that has been improperly installed,
improperly operated or misused based upon industry
standards, or equipment which has not had reasonable
and necessary maintenance, or equipment which has
been used for operation outside of the specifications for
the equipment.
MILLER PRODUCTS ARE INTENDED FOR COMMERCIAL AND
INDUSTRIAL USERS TRAINED AND EXPERIENCED IN THE USE
AND MAINTENANCE OF WELDING EQUIPMENT.
The exclusive remedies for warranty claims are, at Miller’s option,
either: (1) repair; or (2) replacement; or, if approved in writing by
Miller, (3) the pre-approved cost of repair or replacement at an
authorized Miller service station; or (4) payment of or credit for the
purchase price (less reasonable depreciation based upon use).
Products may not be returned without Miller’s written approval.
Return shipment shall be at customer’s risk and expense.
The above remedies are F.O.B. Appleton, WI, or Miller’s authorized
service facility. Transportation and freight are the customer’s
responsibility. TO THE EXTENT PERMITTED BY LAW, THE
REMEDIES HEREIN ARE THE SOLE AND EXCLUSIVE
REMEDIES REGARDLESS OF THE LEGAL THEORY. IN NO
EVENT SHALL MILLER BE LIABLE FOR DIRECT, INDIRECT,
SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES
(INCLUDING LOSS OF PROFIT) REGARDLESS OF THE LEGAL
THEORY. ANY WARRANTY NOT PROVIDED HEREIN AND ANY
IMPLIED WARRANTY, GUARANTY, OR REPRESENTATION,
INCLUDING
ANY
IMPLIED
WARRANTY
OF
MERCHANTABILITY OR FITNESS FOR PARTICULAR
PURPOSE, ARE EXCLUDED AND DISCLAIMED BY MILLER.
Some US states do not allow limiting the duration of an implied
warranty or the exclusion of certain damages, so the above
limitations may not apply to you. This warranty provides specific
legal rights, and other rights may be available depending on your
state. In Canada, some provinces provide additional warranties or
remedies, and to the extent the law prohibits their waiver, the
limitations set out above may not apply. This Limited Warranty
provides specific legal rights, and other rights may be available, but
may vary by province.
miller_warr 2018-01
Owner’s Record
Please complete and retain with your personal records.
Model Name
Serial/Style Number
Purchase Date
(Date which equipment was delivered to original customer.)
Distributor
Address
City
State
Zip
For Service
Contact a DISTRIBUTOR or SERVICE AGENCY near you.
Always provide Model Name and Serial/Style Number.
Contact your Distributor for:
Welding Supplies and Consumables
Options and Accessories
Personal Safety Equipment
Service and Repair
Miller Electric Mfg. LLC
An Illinois Tool Works Company
1635 West Spencer Street
Appleton, WI 54914 USA
Replacement Parts
Training (Schools, Videos, Books)
Technical Manuals (Servicing Information
and Parts)
Circuit Diagrams
For International Locations Visit
www.MillerWelds.com
Welding Process Handbooks
To locate a Distributor or Service Agency visit
www.millerwelds.com or call 1-800-4-A-Miller
Contact the Delivering Carrier to:
File a claim for loss or damage during
shipment.
For assistance in filing or settling claims, contact
your distributor and/or equipment manufacturer’s
Transportation Department.
ORIGINAL INSTRUCTIONS − PRINTED IN USA
International Headquarters−USA
USA Phone: 920-735-4505 Auto-Attended
USA & Canada FAX: 920-735-4134
International FAX: 920-735-4125
© 2018 Miller Electric Mfg. LLC.
2018−01

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project