Miller XMT 350 VS AUTO-LINE W/WCC Owner’s Manual

Add to my manuals
40 Pages

advertisement

Miller XMT 350 VS AUTO-LINE W/WCC Owner’s Manual | Manualzz
OM-252 340D
2013−01
Processes
Multiprocess Welding
Description
Arc Welding Power Source
R
XMT 350 VS
Auto-Line
w/WCC
™
File: MULTIPROCESS
Visit our website at
www.MillerWelds.com
From Miller to You
Thank you and congratulations on choosing Miller. Now you can get
the job done and get it done right. We know you don’t have time to do
it any other way.
That’s why when Niels Miller first started building arc welders in 1929,
he made sure his products offered long-lasting value and superior
quality. Like you, his customers couldn’t afford anything less. Miller
products had to be more than the best they could be. They had to be the
best you could buy.
Today, the people that build and sell Miller products continue the
tradition. They’re just as committed to providing equipment and service
that meets the high standards of quality and value established in 1929.
This Owner’s Manual is designed to help you get the most out of your
Miller products. Please take time to read the Safety precautions. They
will help you protect yourself against potential hazards on the worksite.
We’ve made installation and operation quick
and easy. With Miller you can count on years
of reliable service with proper maintenance.
And if for some reason the unit needs repair,
there’s a Troubleshooting section that will
help you figure out what the problem is. The
Miller is the first welding parts list will then help you to decide the
equipment manufacturer in exact part you may need to fix the problem.
the U.S.A. to be registered to
the ISO 9001 Quality System Warranty and service information for your
Standard.
particular model are also provided.
Miller Electric manufactures a full line
of welders and welding related equipment.
For information on other quality Miller
products, contact your local Miller distributor to receive the latest full
line catalog or individual specification sheets. To locate your nearest
distributor or service agency call 1-800-4-A-Miller, or visit us at
www.MillerWelds.com on the web.
Mil_Thank 2009−09
Working as hard as you do
− every power source from
Miller is backed by the most
hassle-free warranty in the
business.
TABLE OF CONTENTS
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1-3. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4. California Proposition 65 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
4
1-5. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-6. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
4
SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1. Symboles utilisés . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2. Dangers relatifs au soudage à l’arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
5
5
2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance . . . . .
2-4. Proposition californienne 65 Avertissements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
8
2-5. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-6. Informations relatives aux CEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9
9
SECTION 3 − DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1. Additional Safety Symbols And Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
11
3-2. Miscellaneous Symbols And Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 4 − INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
12
4-1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. Volt-Ampere Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12
12
4-3. Duty Cycle And Overheating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 5 − INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-1. Serial Number And Rating Label Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13
14
14
5-2. Dimensions And Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-3. Selecting a Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14
14
5-4. Associating WCC Wire Feeder To WCC Power Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-5. Equipment Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15
15
5-6. Weld Output Terminals And Selecting Cable Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-7. Electrical Service Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16
17
5-8. Connecting 1-Phase Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-9. Connecting 3-Phase Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18
20
5-10. Optional Gas Valve Operation And Shielding Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 − OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-1. Front Panel Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
22
23
23
6-2. Meter Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-3. Mode Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
24
24
6-4. Lift-Arc TIG Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-5. Optional Low Open Circuit Voltage (OCV) Welding Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25
25
SECTION 7 − MAINTENANCE & TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
26
26
7-2. Blowing Out Inside Of Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-3. Help Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
26
27
7-4. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 8 − ELECTRICAL DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 9 − PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27
28
30
WARRANTY
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING
som 2011−10
7
Protect yourself and others from injury — read, follow, and save these important safety precautions and operating instructions.
1-1. Symbol Usage
DANGER! − Indicates a hazardous situation which, if
not avoided, will result in death or serious injury. The
possible hazards are shown in the adjoining symbols
or explained in the text.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury. The possible
hazards are shown in the adjoining symbols or explained in the text.
NOTICE − Indicates statements not related to personal injury.
. Indicates special instructions.
This group of symbols means Warning! Watch Out! ELECTRIC
SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult symbols and related instructions below for necessary actions to avoid the
hazards.
1-2. Arc Welding Hazards
The symbols shown below are used throughout this manual
to call attention to and identify possible hazards. When you
see the symbol, watch out, and follow the related instructions
to avoid the hazard. The safety information given below is
only a summary of the more complete safety information
found in the Safety Standards listed in Section 1-5. Read and
follow all Safety Standards.
Only qualified persons should install, operate, maintain, and
repair this unit.
During operation, keep everybody, especially children, away.
D Always verify the supply ground − check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
grounded receptacle outlet.
D When making input connections, attach proper grounding conductor first − double-check connections.
D Keep cords dry, free of oil and grease, and protected from hot metal
and sparks.
D Frequently inspect input power cord for damage or bare wiring −
replace cord immediately if damaged − bare wiring can kill.
D Turn off all equipment when not in use.
D Do not use worn, damaged, undersized, or poorly spliced cables.
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shocks
or severe burns. The electrode and work circuit is
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also
live when power is on. In semiautomatic or automatic
wire welding, the wire, wire reel, drive roll housing,
and all metal parts touching the welding wire are
electrically live. Incorrectly installed or improperly
grounded equipment is a hazard.
D Do not touch live electrical parts.
D Wear dry, hole-free insulating gloves and body protection.
D Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.
D Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
D Use AC output ONLY if required for the welding process.
D If AC output is required, use remote output control if present on
unit.
D Additional safety precautions are required when any of the following electrically hazardous conditions are present: in damp
locations or while wearing wet clothing; on metal structures such
as floors, gratings, or scaffolds; when in cramped positions such
as sitting, kneeling, or lying; or when there is a high risk of unavoidable or accidental contact with the workpiece or ground. For these
conditions, use the following equipment in order presented: 1) a
semiautomatic DC constant voltage (wire) welder, 2) a DC manual
(stick) welder, or 3) an AC welder with reduced open-circuit voltage. In most situations, use of a DC, constant voltage wire welder
is recommended. And, do not work alone!
D Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
D Properly install, ground, and operate this equipment according to
its Owner’s Manual and national, state, and local codes.
D Do not drape cables over your body.
D If earth grounding of the workpiece is required, ground it directly
with a separate cable.
D Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
D Do not touch electrode holders connected to two welding machines at the same time since double open-circuit voltage will be
present.
D Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
D Wear a safety harness if working above floor level.
D Keep all panels and covers securely in place.
D Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
D Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
D Do not connect more than one electrode or work cable to any
single weld output terminal. Disconnect cable for process not in
use.
SIGNIFICANT DC VOLTAGE exists in inverter welding power sources AFTER removal of input power.
D Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section
before touching any parts.
HOT PARTS can burn.
D Do not touch hot parts bare handed.
D Allow cooling period before working on equipment.
D To handle hot parts, use proper tools and/or
wear heavy, insulated welding gloves and
clothing to prevent burns.
OM-252 340 Page 1
FUMES AND GASES can be hazardous.
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health.
D Keep your head out of the fumes. Do not breathe the fumes.
D If inside, ventilate the area and/or use local forced ventilation at the
arc to remove welding fumes and gases.
D If ventilation is poor, wear an approved air-supplied respirator.
D Read and understand the Material Safety Data Sheets (MSDSs)
and the manufacturer’s instructions for metals, consumables,
coatings, cleaners, and degreasers.
D Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watchperson nearby. Welding fumes and gases can displace air and
lower the oxygen level causing injury or death. Be sure the breathing air is safe.
D Do not weld in locations near degreasing, cleaning, or spraying operations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.
D Do not weld on coated metals, such as galvanized, lead, or
cadmium plated steel, unless the coating is removed from the weld
area, the area is well ventilated, and while wearing an air-supplied
respirator. The coatings and any metals containing these elements
can give off toxic fumes if welded.
ARC RAYS can burn eyes and skin.
Arc rays from the welding process produce intense
visible and invisible (ultraviolet and infrared) rays
that can burn eyes and skin. Sparks fly off from the
weld.
D Wear an approved welding helmet fitted with a proper shade of
filter lenses to protect your face and eyes from arc rays and
sparks when welding or watching (see ANSI Z49.1 and Z87.1
listed in Safety Standards).
D Wear approved safety glasses with side shields under your
helmet.
D Use protective screens or barriers to protect others from flash,
glare and sparks; warn others not to watch the arc.
D Wear protective clothing made from durable, flame-resistant
material (leather, heavy cotton, or wool) and foot protection.
WELDING can cause fire or explosion.
Welding on closed containers, such as tanks,
drums, or pipes, can cause them to blow up. Sparks
can fly off from the welding arc. The flying sparks, hot
workpiece, and hot equipment can cause fires and
burns. Accidental contact of electrode to metal objects can cause
sparks, explosion, overheating, or fire. Check and be sure the area is
safe before doing any welding.
D Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
D Do not weld where flying sparks can strike flammable material.
D Protect yourself and others from flying sparks and hot metal.
D Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
D Watch for fire, and keep a fire extinguisher nearby.
D Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
D Do not weld on containers that have held combustibles, or on
closed containers such as tanks, drums, or pipes unless they are
properly prepared according to AWS F4.1 and AWS A6.0 (see
Safety Standards).
D Do not weld where the atmosphere may contain flammable dust,
gas, or liquid vapors (such as gasoline).
D Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly
unknown paths and causing electric shock, sparks, and fire
hazards.
D Do not use welder to thaw frozen pipes.
OM-252 340 Page 2
D Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
D Wear oil-free protective garments such as leather gloves, heavy
shirt, cuffless trousers, high shoes, and a cap.
D Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.
D After completion of work, inspect area to ensure it is free of sparks,
glowing embers, and flames.
D Use only correct fuses or circuit breakers. Do not oversize or bypass them.
D Follow requirements in OSHA 1910.252 (a) (2) (iv) and NFPA 51B
for hot work and have a fire watcher and extinguisher nearby.
FLYING METAL or DIRT can injure eyes.
D Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool,
they can throw off slag.
D Wear approved safety glasses with side
shields even under your welding helmet.
BUILDUP OF GAS can injure or kill.
D Shut off compressed gas supply when not in use.
D Always ventilate confined spaces or use
approved air-supplied respirator.
ELECTRIC AND MAGNETIC FIELDS (EMF)
can affect Implanted Medical Devices.
D Wearers of Pacemakers and other Implanted
Medical Devices should keep away.
D Implanted Medical Device wearers should consult their doctor
and the device manufacturer before going near arc welding, spot
welding, gouging, plasma arc cutting, or induction heating
operations.
NOISE can damage hearing.
Noise from some processes or equipment can
damage hearing.
D Wear approved ear protection if noise level is
high.
CYLINDERS can explode if damaged.
Compressed gas cylinders contain gas under high
pressure. If damaged, a cylinder can explode. Since
gas cylinders are normally part of the welding
process, be sure to treat them carefully.
D Protect compressed gas cylinders from excessive heat, mechanical shocks, physical damage, slag, open flames, sparks, and arcs.
D Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
D Keep cylinders away from any welding or other electrical circuits.
D Never drape a welding torch over a gas cylinder.
D Never allow a welding electrode to touch any cylinder.
D Never weld on a pressurized cylinder − explosion will result.
D Use only correct compressed gas cylinders, regulators, hoses,
and fittings designed for the specific application; maintain them
and associated parts in good condition.
D Turn face away from valve outlet when opening cylinder valve.
D Keep protective cap in place over valve except when cylinder is in
use or connected for use.
D Use the right equipment, correct procedures, and sufficient number of persons to lift and move cylinders.
D Read and follow instructions on compressed gas cylinders,
associated equipment, and Compressed Gas Association (CGA)
publication P-1 listed in Safety Standards.
1-3. Additional Symbols For Installation, Operation, And Maintenance
FIRE OR EXPLOSION hazard.
BATTERY EXPLOSION can injure.
D Do not install or place unit on, over, or near
combustible surfaces.
D Do not install unit near flammables.
D Do not overload building wiring − be sure power supply system is
properly sized, rated, and protected to handle this unit.
D Do not use welder to charge batteries or jump
start vehicles unless it has a battery charging
feature designed for this purpose.
MOVING PARTS can injure.
D Keep away from moving parts such as fans.
D Keep all doors, panels, covers, and guards
closed and securely in place.
FALLING EQUIPMENT can injure.
D Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
D Use equipment of adequate capacity to lift and
support unit.
D If using lift forks to move unit, be sure forks are long enough to
extend beyond opposite side of unit.
D Keep equipment (cables and cords) away from moving vehicles
when working from an aerial location.
D Follow the guidelines in the Applications Manual for the Revised
NIOSH Lifting Equation (Publication No. 94−110) when manually lifting heavy parts or equipment.
OVERUSE can cause OVERHEATING
D Allow cooling period; follow rated duty cycle.
D Reduce current or reduce duty cycle before
starting to weld again.
D Do not block or filter airflow to unit.
D Have only qualified persons remove doors, panels, covers, or
guards for maintenance and troubleshooting as necessary.
D Reinstall doors, panels, covers, or guards when maintenance is
finished and before reconnecting input power.
READ INSTRUCTIONS.
D Read and follow all labels and the Owner’s
Manual carefully before installing, operating, or
servicing unit. Read the safety information at
the beginning of the manual and in each
section.
D Use only genuine replacement parts from the manufacturer.
D Perform maintenance and service according to the Owner’s
Manuals, industry standards, and national, state, and local
codes.
H.F. RADIATION can cause interference.
FLYING SPARKS can injure.
D Wear a face shield to protect eyes and face.
D Shape tungsten electrode only on grinder with
proper guards in a safe location wearing proper
face, hand, and body protection.
D Sparks can cause fires — keep flammables away.
STATIC (ESD) can damage PC boards.
D
D
D
D
D Put on grounded wrist strap BEFORE handling
boards or parts.
D Use proper static-proof bags and boxes to
store, move, or ship PC boards.
ARC WELDING can cause interference.
MOVING PARTS can injure.
D Keep away from moving parts.
D Keep away from pinch points such as drive
rolls.
D
WELDING WIRE can injure.
D Do not press gun trigger until instructed to do
so.
D Do not point gun toward any part of the body,
other people, or any metal when threading
welding wire.
D High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communications equipment.
D Have only qualified persons familiar with
electronic equipment perform this installation.
The user is responsible for having a qualified electrician promptly correct any interference problem resulting from the installation.
If notified by the FCC about interference, stop using the
equipment at once.
Have the installation regularly checked and maintained.
Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.
D
D
D
D Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.
D Be sure all equipment in the welding area is
electromagnetically compatible.
To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
Locate welding operation 100 meters from any sensitive electronic equipment.
Be sure this welding machine is installed and grounded
according to this manual.
If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables,
using line filters, or shielding the work area.
OM-252 340 Page 3
1-4. California Proposition 65 Warnings
Welding or cutting equipment produces fumes or gases
which contain chemicals known to the State of California to
cause birth defects and, in some cases, cancer. (California
Health & Safety Code Section 25249.5 et seq.)
This product contains chemicals, including lead, known to
the state of California to cause cancer, birth defects, or other
reproductive harm. Wash hands after use.
1-5. Principal Safety Standards
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
is available as a free download from the American Welding Society at
http://www.aws.org or purchased from Global Engineering Documents
(phone: 1-877-413-5184, website: www.global.ihs.com).
Safe Practices for the Preparation of Containers and Piping for Welding
and Cutting, American Welding Society Standard AWS F4.1, from Global Engineering Documents (phone: 1-877-413-5184, website:
www.global.ihs.com).
Safe Practices for Welding and Cutting Containers that have Held Combustibles, American Welding Society Standard AWS A6.0, from Global
Engineering Documents (phone: 1-877-413-5184,
website: www.global.ihs.com).
National Electrical Code, NFPA Standard 70, from National Fire Protection Association, Quincy, MA 02269 (phone: 1-800-344-3555, website:
www.nfpa.org and www. sparky.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 14501 George Carter Way, Suite
103, Chantilly, VA 20151 (phone: 703-788-2700, website:www.cganet.com).
Safety in Welding, Cutting, and Allied Processes, CSA Standard
W117.2, from Canadian Standards Association, Standards Sales, 5060
Spectrum Way, Suite 100, Ontario, Canada L4W 5NS (phone:
800-463-6727, website: www.csa-international.org).
Safe Practice For Occupational And Educational Eye And Face Protection, ANSI Standard Z87.1, from American National Standards Institute,
25 West 43rd Street, New York, NY 10036 (phone: 212-642-4900, website: www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, from National Fire Protection Association,
Quincy, MA 02269 (phone: 1-800-344-3555, website: www.nfpa.org.
OSHA, Occupational Safety and Health Standards for General Industry, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,
and Part 1926, Subpart J, from U.S. Government Printing Office, Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954
(phone: 1-866-512-1800) (there are 10 OSHA Regional Offices—
phone for Region 5, Chicago, is 312-353-2220, website:
www.osha.gov).
Applications Manual for the Revised NIOSH Lifting Equation, The National Institute for Occupational Safety and Health (NIOSH), 1600
Clifton Rd, Atlanta, GA 30333 (phone: 1-800-232-4636, website:
www.cdc.gov/NIOSH).
1-6. EMF Information
Electric current flowing through any conductor causes localized electric
and magnetic fields (EMF). Welding current creates an EMF field
around the welding circuit and welding equipment. EMF fields may interfere with some medical implants, e.g. pacemakers. Protective
measures for persons wearing medical implants have to be taken. For
example, restrict access for passers−by or conduct individual risk assessment for welders. All welders should use the following procedures
in order to minimize exposure to EMF fields from the welding circuit:
1. Keep cables close together by twisting or taping them, or using a
cable cover.
2. Do not place your body between welding cables. Arrange cables
to one side and away from the operator.
3. Do not coil or drape cables around your body.
OM-252 340 Page 4
4. Keep head and trunk as far away from the equipment in the
welding circuit as possible.
5. Connect work clamp to workpiece as close to the weld as
possible.
6. Do not work next to, sit or lean on the welding power source.
7. Do not weld whilst carrying the welding power source or wire
feeder.
About Implanted Medical Devices:
Implanted Medical Device wearers should consult their doctor and the
device manufacturer before performing or going near arc welding, spot
welding, gouging, plasma arc cutting, or induction heating operations.
If cleared by your doctor, then following the above procedures is recommended.
SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION
fre_som_2011−10
7
Pour écarter les risques de blessure pour vous−même et pour autrui — lire, appliquer et ranger en lieu sûr ces consignes relatives
aux précautions de sécurité et au mode opératoire.
2-1. Symboles utilisés
DANGER! − Indique une situation dangereuse qui si on
l’évite pas peut donner la mort ou des blessures graves.
Les dangers possibles sont montrés par les symboles
joints ou sont expliqués dans le texte.
Indique une situation dangereuse qui si on l’évite pas
peut donner la mort ou des blessures graves. Les dangers possibles sont montrés par les symboles joints ou
sont expliqués dans le texte.
NOTE − Indique des déclarations pas en relation avec des blessures
personnelles.
. Indique des instructions spécifiques.
Ce groupe de symboles veut dire Avertissement! Attention! DANGER
DE CHOC ELECTRIQUE, PIECES EN MOUVEMENT, et PIECES
CHAUDES. Consulter les symboles et les instructions ci-dessous y
afférant pour les actions nécessaires afin d’éviter le danger.
2-2. Dangers relatifs au soudage à l’arc
Les symboles représentés ci-dessous sont utilisés dans ce manuel pour attirer l’attention et identifier les dangers possibles. En
présence de l’un de ces symboles, prendre garde et suivre les
instructions afférentes pour éviter tout risque. Les instructions
en matière de sécurité indiquées ci-dessous ne constituent
qu’un sommaire des instructions de sécurité plus complètes
fournies dans les normes de sécurité énumérées dans la Section 2-5. Lire et observer toutes les normes de sécurité.
Seul un personnel qualifié est autorisé à installer, faire fonctionner, entretenir et réparer cet appareil.
Pendant le fonctionnement, maintenir à distance toutes les
personnes, notamment les enfants de l’appareil.
UNE DÉCHARGE ÉLECTRIQUE peut
entraîner la mort.
Le contact d’organes électriques sous tension peut
provoquer des accidents mortels ou des brûlures
graves. Le circuit de l’électrode et de la pièce est
sous tension lorsque le courant est délivré à la
sortie. Le circuit d’alimentation et les circuits internes de la machine sont également sous tension
lorsque l’alimentation est sur Marche. Dans le mode
de soudage avec du fil, le fil, le dérouleur, le bloc de
commande du rouleau et toutes les parties métalliques en contact avec le fil sont sous tension
électrique. Un équipement installé ou mis à la terre
de manière incorrecte ou impropre constitue un
danger.
D Ne pas toucher aux pièces électriques sous tension.
D Porter des gants isolants et des vêtements de protection secs et
sans trous.
D S’isoler de la pièce à couper et du sol en utilisant des housses ou
des tapis assez grands afin d’éviter tout contact physique avec la
pièce à couper ou le sol.
D Ne pas se servir de source électrique à courant électrique dans les
zones humides, dans les endroits confinés ou là où on risque de
tomber.
D Se servir d’une source électrique à courant électrique UNIQUEMENT si le procédé de soudage le demande.
D Si l’utilisation d’une source électrique à courant électrique s’avère
nécessaire, se servir de la fonction de télécommande si l’appareil
en est équipé.
D D’autres consignes de sécurité sont nécessaires dans les conditions suivantes : risques électriques dans un environnement
humide ou si l’on porte des vêtements mouillés ; sur des structures
métalliques telles que sols, grilles ou échafaudages ; en position
coincée comme assise, à genoux ou couchée ; ou s’il y a un risque
élevé de contact inévitable ou accidentel avec la pièce à souder ou
le sol. Dans ces conditions, utiliser les équipements suivants,
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
dans l’ordre indiqué : 1) un poste à souder DC à tension constante
(à fil), 2) un poste à souder DC manuel (électrode) ou 3) un poste à
souder AC à tension à vide réduite. Dans la plupart des situations,
l’utilisation d’un poste à souder DC à fil à tension constante est recommandée. En outre, ne pas travailler seul !
Couper l’alimentation ou arrêter le moteur avant de procéder à l’installation, à la réparation ou à l’entretien de l’appareil. Déverrouiller
l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de sécurité).
Installez, mettez à la terre et utilisez correctement cet équipement
conformément à son Manuel d’Utilisation et aux réglementations
nationales, gouvernementales et locales.
Toujours vérifier la terre du cordon d’alimentation. Vérifier et
s’assurer que le fil de terre du cordon d’alimentation est bien
raccordé à la borne de terre du sectionneur ou que la fiche du
cordon est raccordée à une prise correctement mise à la terre.
En effectuant les raccordements d’entrée, fixer d’abord le conducteur de mise à la terre approprié et contre-vérifier les connexions.
Les câbles doivent être exempts d’humidité, d’huile et de graisse;
protégez−les contre les étincelles et les pièces métalliques
chaudes.
Vérifier fréquemment le cordon d’alimentation afin de s’assurer
qu’il n’est pas altéré ou à nu, le remplacer immédiatement s’il l’est.
Un fil à nu peut entraîner la mort.
L’équipement doit être hors tension lorsqu’il n’est pas utilisé.
Ne pas utiliser des câbles usés, endommagés, de grosseur insuffisante ou mal épissés.
Ne pas enrouler les câbles autour du corps.
Si la pièce soudée doit être mise à la terre, le faire directement
avec un câble distinct.
Ne pas toucher l’électrode quand on est en contact avec la pièce,
la terre ou une électrode provenant d’une autre machine.
Ne pas toucher des porte électrodes connectés à deux machines
en même temps à cause de la présence d’une tension à vide doublée.
N’utiliser qu’un matériel en bon état. Réparer ou remplacer sur-lechamp les pièces endommagées. Entretenir l’appareil conformément à ce manuel.
Porter un harnais de sécurité si l’on doit travailler au-dessus du sol.
S’assurer que tous les panneaux et couvercles sont correctement
en place.
Fixer le câble de retour de façon à obtenir un bon contact métalmétal avec la pièce à souder ou la table de travail, le plus près possible de la soudure.
Isoler la pince de masse quand pas mis à la pièce pour éviter le
contact avec tout objet métallique.
Ne pas raccorder plus d’une électrode ou plus d’un câble de
masse à une même borne de sortie de soudage. Débrancher le
câble pour le procédé non utilisé.
OM-252 340 Page 5
Il reste une TENSION DC NON NÉGLIGEABLE dans
les sources de soudage onduleur UNE FOIS
l’alimentation coupée.
D Arrêter les convertisseurs, débrancher le courant électrique et
décharger les condensateurs d’alimentation selon les instructions
indiquées dans la partie Entretien avant de toucher les pièces.
LES PIÈCES CHAUDES peuvent
provoquer des brûlures.
D Ne pas toucher à mains nues les parties
chaudes.
D Prévoir une période de refroidissement avant de
travailler à l’équipement.
D Ne pas toucher aux pièces chaudes, utiliser les outils recommandés et porter des gants de soudage et des vêtements épais pour
éviter les brûlures.
LE SOUDAGE peut provoquer un
incendie ou une explosion.
Le soudage effectué sur des conteneurs fermés tels
que des réservoirs, tambours ou des conduites peut
provoquer leur éclatement. Des étincelles peuvent
être projetées de l’arc de soudure. La projection d’étincelles, des
pièces chaudes et des équipements chauds peut provoquer des
incendies et des brûlures. Le contact accidentel de l’électrode avec
des objets métalliques peut provoquer des étincelles, une explosion,
un surchauffement ou un incendie. Avant de commencer le soudage,
vérifier et s’assurer que l’endroit ne présente pas de danger.
D Déplacer toutes les substances inflammables à une distance de
10,7 m de l’arc de soudage. En cas d’impossibilité les recouvrir
soigneusement avec des protections homologués.
D Ne pas souder dans un endroit là où des étincelles peuvent tomber
sur des substances inflammables.
LES FUMÉES ET LES GAZ peuvent
être dangereux.
D Se protéger et d’autres personnes de la projection d’étincelles et
de métal chaud.
Le soudage génère des fumées et des gaz. Leur
inhalation peut être dangereux pour votre santé.
D Des étincelles et des matériaux chauds du soudage peuvent
facilement passer dans d’autres zones en traversant de petites
fissures et des ouvertures.
D Eloigner votre tête des fumées. Ne pas respirer les fumées.
D Surveiller tout déclenchement d’incendie et tenir un extincteur à
proximité.
D À l’intérieur, ventiler la zone et/ou utiliser une ventilation forcée au
niveau de l’arc pour l’évacuation des fumées et des gaz de
soudage.
D Le soudage effectué sur un plafond, plancher, paroi ou séparation
peut déclencher un incendie de l’autre côté.
D Si la ventilation est médiocre, porter un respirateur anti-vapeurs
approuvé.
D Lire et comprendre les spécifications de sécurité des matériaux
(MSDS) et les instructions du fabricant concernant les métaux, les
consommables, les revêtements, les nettoyants et les dégraisseurs.
D Travailler dans un espace fermé seulement s’il est bien ventilé ou
en portant un respirateur à alimentation d’air. Demander toujours à
un surveillant dûment formé de se tenir à proximité. Des fumées et
des gaz de soudage peuvent déplacer l’air et abaisser le niveau
d’oxygène provoquant des blessures ou des accidents mortels.
S’assurer que l’air de respiration ne présente aucun danger.
D Ne pas souder dans des endroits situés à proximité d’opérations
de dégraissage, de nettoyage ou de pulvérisation. La chaleur et
les rayons de l’arc peuvent réagir en présence de vapeurs et former des gaz hautement toxiques et irritants.
D Ne pas souder des métaux munis d’un revêtement, tels que l’acier
galvanisé, plaqué en plomb ou au cadmium à moins que le revêtement n’ait été enlevé dans la zone de soudure, que l’endroit soit
bien ventilé, et en portant un respirateur à alimentation d’air. Les
revêtements et tous les métaux renfermant ces éléments peuvent
dégager des fumées toxiques en cas de soudage.
LES RAYONS DE L’ARC peuvent
provoquer des brûlures dans les
yeux et sur la peau.
Le rayonnement de l’arc du procédé de soudage
génère des rayons visibles et invisibles intenses
(ultraviolets et infrarouges) susceptibles de provoquer des brûlures
dans les yeux et sur la peau. Des étincelles sont projetées pendant le
soudage.
D Porter un casque de soudage approuvé muni de verres filtrants
approprié pour protéger visage et yeux pour protéger votre visage
et vos yeux pendant le soudage ou pour regarder (voir ANSI Z49.1
et Z87.1 énuméré dans les normes de sécurité).
D Porter des lunettes de sécurité avec écrans latéraux même sous
votre casque.
D Avoir recours à des écrans protecteurs ou à des rideaux pour
protéger les autres contre les rayonnements les éblouissements
et les étincelles ; prévenir toute personne sur les lieux de ne pas
regarder l’arc.
D Porter des vêtements confectionnés avec des matières résistantes et ignifuges (cuir, coton lourd ou laine) et des bottes de
protection.
OM-252 340 Page 6
D Ne pas effectuer le soudage sur des conteneurs fermés tels que
des réservoirs, tambours, ou conduites, à moins qu’ils n’aient été
préparés correctement conformément à AWS F4.1 et AWS A6.0
(voir les Normes de Sécurité).
D Ne soudez pas si l’air ambiant est chargé de particules, gaz, ou vapeurs inflammables (vapeur d’essence, par exemple).
D Brancher le câble de masse sur la pièce le plus près possible de la
zone de soudage pour éviter le transport du courant sur une
longue distance par des chemins inconnus éventuels en provoquant des risques d’électrocution, d’étincelles et d’incendie.
D Ne pas utiliser le poste de soudage pour dégeler des conduites gelées.
D En cas de non utilisation, enlever la baguette d’électrode du porteélectrode ou couper le fil à la pointe de contact.
D Porter des vêtements de protection dépourvus d’huile tels que des
gants en cuir, une chemise en matériau lourd, des pantalons sans
revers, des chaussures hautes et un couvre chef.
D Avant de souder, retirer toute substance combustible de vos poches telles qu’un allumeur au butane ou des allumettes.
D Une fois le travail achevé, assurez−vous qu’il ne reste aucune
trace d’étincelles incandescentes ni de flammes.
D Utiliser exclusivement des fusibles ou coupe−circuits appropriés.
Ne pas augmenter leur puissance; ne pas les ponter.
D Une fois le travail achevé, assurez−vous qu’il ne reste aucune
trace d’étincelles incandescentes ni de flammes.
D Utiliser exclusivement des fusibles ou coupe−circuits appropriés.
Ne pas augmenter leur puissance; ne pas les ponter.
D Suivre les recommandations dans OSHA 1910.252(a)(2)(iv) et
NFPA 51B pour les travaux à chaud et avoir de la surveillance et un
extincteur à proximité.
DES PIECES DE METAL ou DES
SALETES peuvent provoquer des
blessures dans les yeux.
D Le soudage, l’écaillement, le passage de la pièce à la brosse en
fil de fer, et le meulage génèrent des étincelles et des particules
métalliques volantes. Pendant la période de refroidissement des
soudures, elles risquent de projeter du laitier.
D Porter des lunettes de sécurité avec écrans latéraux ou un écran
facial.
LES ACCUMULATIONS DE GAZ
risquent de provoquer des blessures
ou même la mort.
D Fermer l’alimentation du gaz comprimé en cas
de non utilisation.
D Veiller toujours à bien aérer les espaces confinés ou se servir d’un respirateur d’adduction
d’air homologué.
Les CHAMPS ÉLECTROMAGNÉTIQUES (CEM)
peuvent affecter les implants médicaux.
D Les porteurs de stimulateurs cardiaques et
autres implants médicaux doivent rester à
distance.
D Les porteurs d’implants médicaux doivent consulter leur
médecin et le fabricant du dispositif avant de s’approcher de la
zone où se déroule du soudage à l’arc, du soudage par points, du
gougeage, de la découpe plasma ou une opération de chauffage
par induction.
LE BRUIT peut endommager l’ouïe.
Le bruit des processus et des équipements peut
affecter l’ouïe.
D Porter des protections approuvées pour les
oreilles si le niveau sonore est trop élevé.
LES BOUTEILLES peuvent exploser
si elles sont endommagées.
Les bouteilles de gaz comprimé contiennent du gaz
sous haute pression. Si une bouteille est
endommagée, elle peut exploser. Du fait que les
bouteilles de gaz font normalement partie du
procédé de soudage, les manipuler avec
précaution.
D Protéger les bouteilles de gaz comprimé d’une chaleur excessive,
des chocs mécaniques, des dommages physiques, du laitier, des
flammes ouvertes, des étincelles et des arcs.
D Placer les bouteilles debout en les fixant dans un support stationnaire ou dans un porte-bouteilles pour les empêcher de tomber ou
de se renverser.
D Tenir les bouteilles éloignées des circuits de soudage ou autres
circuits électriques.
D Ne jamais placer une torche de soudage sur une bouteille à gaz.
D Une électrode de soudage ne doit jamais entrer en contact avec
une bouteille.
D Ne jamais souder une bouteille pressurisée − risque d’explosion.
D Utiliser seulement des bouteilles de gaz comprimé, régulateurs,
tuyaux et raccords convenables pour cette application spécifique;
les maintenir ainsi que les éléments associés en bon état.
D Détourner votre visage du détendeur-régulateur lorsque vous
ouvrez la soupape de la bouteille.
D Le couvercle du détendeur doit toujours être en place, sauf lorsque
la bouteille est utilisée ou qu’elle est reliée pour usage ultérieur.
D Utiliser les équipements corrects, les bonnes procédures et suffisamment de personnes pour soulever et déplacer les bouteilles.
D Lire et suivre les instructions sur les bouteilles de gaz comprimé,
l’équipement connexe et le dépliant P-1 de la CGA (Compressed
Gas Association) mentionné dans les principales normes de sécurité.
2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance
Risque D’INCENDIE OU
D’EXPLOSION.
D Ne pas placer l’appareil sur, au-dessus ou
à proximité de surfaces inflammables.
D Ne pas installer l’appareil à proximité de produits inflammables.
D Ne pas surcharger l’installation électrique − s’assurer que
l’alimentation est correctement dimensionnée et protégée avant
de mettre l’appareil en service.
LA CHUTE DE L’ÉQUIPEMENT peut
provoquer des blessures.
D Utiliser l’anneau de levage uniquement pour
soulever l’appareil, NON PAS les chariots, les
bouteilles de gaz ou tout autre accessoire.
D Utiliser un équipement de levage de capacité
suffisante pour lever l’appareil.
D En utilisant des fourches de levage pour déplacer l’unité, s’assurer que les fourches sont suffisamment longues pour dépasser
du côté opposé de l’appareil.
D Tenir l’équipement (câbles et cordons) à distance des véhicules
mobiles lors de toute opération en hauteur.
D Suivre les consignes du Manuel des applications pour l’équation
de levage NIOSH révisée (Publication Nº94–110) lors du levage
manuelle de pièces ou équipements lourds.
L’EMPLOI
EXCESSIF
peut
SURCHAUFFER L’ÉQUIPEMENT.
D Prévoir une période de refroidissement ; respecter le cycle opératoire nominal.
D Réduire le courant ou le facteur de marche
avant de poursuivre le soudage.
D Ne pas obstruer les passages d’air du poste.
LES ÉTINCELLES PROJETÉES
peuvent provoquer des blessures.
D Porter un écran facial pour protéger le visage et
les yeux.
D Affûter l’électrode au tungstène uniquement à la
meuleuse dotée de protecteurs. Cette
manœuvre est à exécuter dans un endroit sûr
lorsque l’on porte l’équipement homologué de
protection du visage, des mains et du corps.
D Les étincelles risquent de causer un incendie − éloigner toute substance inflammable.
LES CHARGES ÉLECTROSTATIQUES peuvent endommager les circuits imprimés.
D Établir la connexion avec la barrette de terre
avant de manipuler des cartes ou des pièces.
D Utiliser des pochettes et des boîtes antistatiques pour stocker, déplacer ou expédier des
cartes de circuits imprimes.
OM-252 340 Page 7
Les PIÈCES MOBILES peuvent
causer des blessures.
LE
RAYONNEMENT
HAUTE
FRÉQUENCE
(H.F.)
risque
de
provoquer des interférences.
D Ne pas s’approcher des organes mobiles.
D Ne pas s’approcher des points de coincement
tels que des rouleaux de commande.
D Le rayonnement haute fréquence (H.F.) peut
provoquer des interférences avec les équipements de radio−navigation et de communication, les services de sécurité et les ordinateurs.
LES FILS DE SOUDAGE peuvent
provoquer des blessures.
D Ne pas appuyer sur la gâchette avant d’en
avoir reçu l’instruction.
D Ne pas diriger le pistolet vers soi, d’autres
personnes ou toute pièce mécanique en
engageant le fil de soudage.
L’EXPLOSION DE LA BATTERIE
peut provoquer des blessures.
D Ne pas utiliser l’appareil de soudage pour
charger des batteries ou faire démarrer
des véhicules à l’aide de câbles de démarrage,
sauf si l’appareil dispose d’une fonctionnalité
de charge de batterie destinée à cet usage.
D Demander seulement à des personnes qualifiées familiarisées
avec des équipements électroniques de faire fonctionner l’installation.
D L’utilisateur est tenu de faire corriger rapidement par un électricien
qualifié les interférences résultant de l’installation.
D Si le FCC signale des interférences, arrêter immédiatement l’appareil.
D Effectuer régulièrement le contrôle et l’entretien de l’installation.
D Maintenir soigneusement fermés les portes et les panneaux des
sources de haute fréquence, maintenir les éclateurs à une distance correcte et utiliser une terre et un blindage pour réduire les
interférences éventuelles.
Les PIÈCES MOBILES peuvent
causer des blessures.
D S’abstenir de toucher des organes mobiles tels
que des ventilateurs.
D Maintenir fermés et verrouillés les portes,
panneaux, recouvrements et dispositifs de
protection.
D Lorsque cela est nécessaire pour des travaux d’entretien et de
dépannage, faire retirer les portes, panneaux, recouvrements
ou dispositifs de protection uniquement par du personnel qualifié.
D Remettre les portes, panneaux, recouvrements ou dispositifs de
protection quand l’entretien est terminé et avant de rebrancher
l’alimentation électrique.
LIRE LES INSTRUCTIONS.
D Lire et appliquer les instructions sur les
étiquettes et le Mode d’emploi avant l’installation, l’utilisation ou l’entretien de l’appareil.
Lire les informations de sécurité au début du
manuel et dans chaque section.
D N’utiliser que les pièces de rechange recommandées par le
constructeur.
D Effectuer l’entretien en respectant les manuels d’utilisation, les
normes industrielles et les codes nationaux, d’état et locaux.
LE SOUDAGE À L’ARC risque de
provoquer des interférences.
D
D
D
D
D
D L’énergie électromagnétique risque de
provoquer des interférences pour l’équipement
électronique sensible tel que les ordinateurs et
l’équipement commandé par ordinateur tel que
les robots.
Veiller à ce que tout l’équipement de la zone de soudage soit
compatible électromagnétiquement.
Pour réduire la possibilité d’interférence, maintenir les câbles de
soudage aussi courts que possible, les grouper, et les poser
aussi bas que possible (ex. par terre).
Veiller à souder à une distance de 100 mètres de tout équipement électronique sensible.
Veiller à ce que ce poste de soudage soit posé et mis à la terre
conformément à ce mode d’emploi.
En cas d’interférences après avoir pris les mesures précédentes, il incombe à l’utilisateur de prendre des mesures supplémentaires telles que le déplacement du poste, l’utilisation de câbles blindés, l’utilisation de filtres de ligne ou la pose de protecteurs dans la zone de travail.
2-4. Proposition californienne 65 Avertissements
Les équipements de soudage et de coupage produisent des
fumées et des gaz qui contiennent des produits chimiques
dont l’État de Californie reconnaît qu’ils provoquent des malformations congénitales et, dans certains cas, des cancers.
(Code de santé et de sécurité de Californie, chapitre 25249.5
et suivants)
OM-252 340 Page 8
Ce produit contient des produits chimiques, notamment du
plomb, dont l’État de Californie reconnaît qu’ils provoquent
des cancers, des malformations congénitales ou d’autres
problèmes de procréation. Se laver les mains après
utilisation.
2-5. Principales normes de sécurité
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
is available as a free download from the American Welding Society at
http://www.aws.org or purchased from Global Engineering Documents
(phone: 1-877-413-5184, website: www.global.ihs.com).
Safe Practices for the Preparation of Containers and Piping for Welding
and Cutting, American Welding Society Standard AWS F4.1, from Global Engineering Documents (phone: 1-877-413-5184, website:
www.global.ihs.com).
Safe Practices for Welding and Cutting Containers that have Held Combustibles, American Welding Society Standard AWS A6.0, from Global
Engineering Documents (phone: 1-877-413-5184,
website: www.global.ihs.com).
National Electrical Code, NFPA Standard 70, from National Fire Protection Association, Quincy, MA 02269 (phone: 1-800-344-3555, website:
www.nfpa.org and www. sparky.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 14501 George Carter Way, Suite
103, Chantilly, VA 20151 (phone: 703-788-2700, website:www.cganet.com).
Safety in Welding, Cutting, and Allied Processes, CSA Standard
W117.2, from Canadian Standards Association, Standards Sales, 5060
Spectrum Way, Suite 100, Ontario, Canada L4W 5NS (phone:
800-463-6727, website: www.csa-international.org).
Safe Practice For Occupational And Educational Eye And Face Protection, ANSI Standard Z87.1, from American National Standards Institute,
25 West 43rd Street, New York, NY 10036 (phone: 212-642-4900, website: www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, from National Fire Protection Association,
Quincy, MA 02269 (phone: 1-800-344-3555, website: www.nfpa.org.
OSHA, Occupational Safety and Health Standards for General Industry, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,
and Part 1926, Subpart J, from U.S. Government Printing Office, Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954
(phone: 1-866-512-1800) (there are 10 OSHA Regional Offices—
phone for Region 5, Chicago, is 312-353-2220, website:
www.osha.gov).
Applications Manual for the Revised NIOSH Lifting Equation, The National Institute for Occupational Safety and Health (NIOSH), 1600
Clifton Rd, Atlanta, GA 30333 (phone: 1-800-232-4636, website:
www.cdc.gov/NIOSH).
2-6. Informations relatives aux CEM
Le courant électrique qui traverse tout conducteur génère des champs
électromagnétiques (CEM) à certains endroits. Le courant de soudage
crée un CEM autour du circuit et du matériel de soudage. Les CEM
peuvent créer des interférences avec certains implants médicaux
comme des stimulateurs cardiaques. Des mesures de protection pour
les porteurs d’implants médicaux doivent être prises: Limiter par
exemple tout accès aux passants ou procéder à une évaluation des
risques individuels pour les soudeurs. Tous les soudeurs doivent
appliquer les procédures suivantes pour minimiser l’exposition aux
CEM provenant du circuit de soudage:
4. Maintenir la tête et le torse aussi loin que possible du matériel du
circuit de soudage.
1. Rassembler les câbles en les torsadant ou en les attachant avec
du ruban adhésif ou avec une housse.
2. Ne pas se tenir au milieu des câbles de soudage. Disposer les
câbles d’un côté et à distance de l’opérateur.
3. Ne pas courber et ne pas entourer les câbles autour de votre
corps.
En ce qui concerne les implants médicaux :
5. Connecter la pince sur la pièce aussi près que possible de la
soudure.
6. Ne pas travailler à proximité d’une source de soudage, ni
s’asseoir ou se pencher dessus.
7. Ne pas souder tout en portant la source de soudage ou le
dévidoir.
Les porteurs d’implants doivent d’abord consulter leur médecin avant
de s’approcher des opérations de soudage à l’arc, de soudage par
points, de gougeage, du coupage plasma ou de chauffage par induction. Si le médecin approuve, il est recommandé de suivre les
procédures précédentes.
OM-252 340 Page 9
OM-252 340 Page 10
SECTION 3 − DEFINITIONS
3-1. Additional Safety Symbols And Definitions
. Some symbols are found only on CE products.
Warning! Watch Out! There are possible hazards as shown by the symbols.
Safe1 2012−05
When power is applied failed parts can explode or cause other parts to explode.
Safe89 2012−07
3-2. Miscellaneous Symbols And Definitions
A
I1max
Amperage
V
Voltage
On
Off
Increase
Positive
Negative
Voltage Input
Scratch Start TIG
Shielded Metal Arc
Welding (SMAW)
Voltage Sensing
Feeder
Lift-Arc Operation
(GTAW)
Rated Maximum
Supply Current
I1eff
Maximum Effective
Supply Current
Notes
OM-252 340 Page 11
SECTION 4 − INTRODUCTION
4-1. Specifications
Input
Power
Rated Output
3-Phase
350 A at 34
VDC, 60%
Duty Cycle
1-Phase
300 A at 32
VDC, 60%
Duty Cycle*
Voltage
Range in CV Mode
Amperage
Range in
CC Mode
Max.
OpenCircuit
Voltage
10−38 V
10−425 A
75 VDC
RMS Amps Input at Rated Load Output,
60 Hz 3-Phase at NEMA Load Voltages
and Class I Rating
208 V
230 V
400 V
460 V
575 V
KVA
KW
40.4
36.1
20.6
17.8
14.1
14.2
13.6
60.8
54.6
29.7
25.4
19.9
11.7
11.2
*See Section 4-3 for Duty Cycle Rating.
4-2. Volt-Ampere Curves
Volt-ampere curves show minimum
and maximum voltage and amperage output capabilities of welding
power source. Curves of other settings fall between curves shown.
A. CC Mode
100
90
80
VOLTS
70
60
50
SMAW
MAX
40
30
GTAW
MN
20
GTAW
MAX
SMAW
80A
0%
25%
ARC
CONTROL
50%
10
75%
100%
0
0
100
200
300
400
500
400
5 00
AMPERAGE
B. CV Mode
100
90
80
VOLTS
70
60
50
MAX
40
30
20
MIN
10
0
0
100
200
300
AMPERAGE
217 836-A / 217 837-B
OM-252 340 Page 12
4-3. Duty Cycle And Overheating
Duty Cycle is percentage of 10 minutes that unit can weld at rated load
without overheating.
If unit overheats, output stops, a
Help message is displayed and
cooling fan runs. Wait fifteen minutes for unit to cool. Reduce amperage or voltage, or duty cycle before
welding.
. Single Phase Operation: The
unit is supplied with a 8 AWG
power cord. The rated output
with 8 AWG is 300 amps, 32
volts at 40% duty cycle. To
achieve 60% duty cycle
change cord to 6 AWG.
NOTICE − Exceeding duty cycle
can damage unit and void warranty.
60% Duty Cycle
6 Minutes Welding
Overheating
4 Minutes Resting
A or V
0
15
Minutes
OR
Reduce Duty Cycle
Ref. 216 568-A
Notes
OM-252 340 Page 13
SECTION 5 − INSTALLATION
5-1. Serial Number And Rating Label Location
The serial number and rating information for this product is located on the rear panel. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on back cover of this manual.
5-2. Dimensions And Weight
A
Hole Layout Dimensions
E
F
A
11-3/4 in. (298 mm)
B
1-11/16 in. (42 mm)
C
15-3/4 in. (400 mm)
G
24 in.
(610 mm)
17 in.
(432 mm)
D
C
D
19-3/32 in. (485 mm)
12-1/2 in.
(318 mm)
E
8-11/16 in. (221 mm)
F
1-17/32 in. (39 mm)
G
1/4-20 UNC -2B thread
B
804 801-A
Weight
71 lb (32.2 kg)
5-3. Selecting a Location
Movement
1
8
Lifting Handles
Use handles to lift unit.
!
9
1
Do not move or operate unit
where it could tip.
Hand Cart
Use cart or similar device to move
unit.
10 Line Disconnect Device
Locate unit near correct input
power supply.
!
2
Location
Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
3
18 in.
(460 mm)
18 in.
(460 mm)
OM-252 340 Page 14
loc_2 3/96 - Ref. ST-151 556 / Ref. 803 691-C
5-4. Associating WCC Wire Feeder To WCC Power Source
Quick Setup Guide:
1
2
3
4
5
To associate the 350 VS w/WCC select any process except LIFT ARC TIG.
Pull trigger on gun.
Do not strike an arc.
Decimal points on feeder voltmeter will blink.
When decimal points stop blinking and a voltage is displayed on the feeder or when REMOTE IN USE light on Power Source front panel
becomes lit, the feeder and power source are associated.
Use voltage control on feeder to adjust weld voltage.
Voltmeter on feeder will alternate between preset voltage and open circuit voltage while idle. While welding the feeder will display the actual
weld voltage at the wire feeder.
6
7
. See Section 5-5 for detailed equipment setup.
5-5. Equipment Setup
. During
WCC operation, preset weld
voltage and wire feed speed are set at the
wire feeder front panel.
Associating a WCC compatible wire feeder, and WCC welding power source:
1
2
3
On power source- set front panel mode
switch to any process except LIFT ARC
TIG (Power source will not associate in
LIFT ARC TIG mode).
On wire feeder - set CC/CV switch to
CV. The feeder will not associate to a
WCC power source if the feeder is set
to CC.
The welding power source voltage
display alternates between preset
voltage (set at the welding power
source) and open circuit voltage. The
wire feeder voltage display will alternate
between three dashes and open circuit
voltage.
For the wire feeder to control the
welding power source the wire feeder
must be associated to it. If wire feeder is
not associated to the power source, the
wire feeder will try to associate when the
trigger is pulled. To associate the wire
feeder to the power source, pull and
hold the welding gun trigger − DO NOT
STRIKE AN ARC. While the association
4
5
6
process is taking place the decimal
points on the wire feeder voltage display
will blink. When associated, the decimal
points stop blinking and the REMOTE IN
USE light on the power source front
panel will light and preset voltage is
displayed. Release trigger on welding
gun after preset voltage is displayed.
The association process may take up to
five seconds to complete.
Once association is complete the
voltage display on the wire feeder will
alternate between preset voltage and
open circuit voltage. The voltage display
on the welding power source will
alternate between preset voltage (set by
the wire feeder) and open circuit
voltage. Preset voltages between the
wire feeder and the welding power
source should be within 0.5 volt of each
other.
While adjusting the voltage control on
the feeder the voltage display will show
only preset voltage. Ten seconds after
the preset voltage has been set the
display will alternate between preset
voltage and open circuit voltage.
While welding the welding power source
displays weld voltage at the studs. The
wire feeder displays weld voltage at wire
feeder.
7
8
9
While welding, due to voltage drops in
the weld cable, voltage displays at wire
feeder and welding power source may
not match. The preset voltage at wire
feeder may need to be set to a higher
value to compensate for voltage drop of
the weld cable. For example, if welding
voltage of 18 volts is desired at the wire
feeder and there is a 4 volt drop in the
weld cable, the preset voltage at the
wire feeder should be 22 volts. (18V +
4V = 22V).
Once wire feeder and power source are
associated, they will stay associated
until either the wire feeder or welding
power source loses power. The wire
feeder can lose power for up to ten
seconds and still recover its association
with the power source. This is for
situations where the wire feeder may
momentarily lose power due to a
prolonged short circuit condition in the
welding process.
If the CC/CV switch on the feeder is
changed to CC the feeder will still be
associated. The feeder Voltage display
will show CC. The voltage knob on
feeder will still control voltage output on
the power source but the WFS will run
about 150 IPM less than the present
speed.
OM-252 340 Page 15
5-6. Weld Output Terminals And Selecting Cable Sizes
NOTICE − The Total Cable Length in Weld Circuit (see table below) is the combined length of both weld cables. For example, if the power source is
100 ft (30 m) from the workpiece, the total cable length in the weld circuit is 200 ft (2 cables x 100 ft). Use the 200 ft (60 m) column to determine cable
size.
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit
Not Exceeding***
Weld Output
Terminals
!
Turn off power before connecting to
weld output terminals.
!
Do not use worn,
damaged,
undersized, or poorly
spliced cables.
100 ft (30 m) or Less
Welding
Amperes
+
10 − 60%
Duty Cycle
AWG (mm2)
150 ft
(45 m)
200 ft
(60 m)
60 − 100%
Duty
Cycle
* This
300 ft
(90 m)
350 ft
400 ft
(105 m) (120 m)
10 − 100% Duty Cycle
AWG (mm2)
AWG (mm2)
100
4 (20)
4 (20)
4 (20)
3 (30)
2 (35)
1 (50)
1/0 (60)
1/0 (60)
150
3 (30)
3 (30)
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
3/0 (95)
200
3 (30)
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
4/0 (120)
250
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2x2/0
(2x70)
2x2/0
(2x70)
300
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2x2/0
(2x70)
2x3/0
(2x95)
2x3/0
(2x95)
350
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2x2/0
(2x70)
2x3/0
(2x95)
2x3/0
(2x95)
2x4/0
(2x120)
400
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2x2/0
(2x70)
2x3/0
(2x95)
2x4/0
(2x120)
2x4/0
(2x120)
500
2/0 (70)
3/0 (95)
4/0 (120)
2x2/0
(2x70)
2x3/0
(2x95)
2x4/0
(2x120)
3x3/0
(3x95)
3x3/0
(3x95)
600
3/0 (95)
4/0 (120)
2x2/0
(2x70)
2x3/0
(2x95)
2x4/0
(2x120)
3x3/0
(3x95)
3x4/0
(3x120)
3x4/0
(3x120)
−
Output Receptacles
250 ft
(70 m)
chart is a general guideline and may not suit all applications. If cable overheats, use next size larger cable.
**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
( ) = mm2 for metric use
***For distances longer than those shown in this guide, call a factory applications rep. at 920-735-4505 (Miller) or 1-800-332-3281 (Hobart).
Ref. S-0007-J 2011−07
OM-252 340 Page 16
5-7. Electrical Service Guide
Elec Serv 2011−08
NOTICE − INCORRECT INPUT POWER can damage this welding power source. Phase to ground voltage shall not exceed +10% of rated input
voltage.
NOTICE − Actual input voltage should not be 10% less than minimum and/or 10% more than maximum input voltages listed in table. If actual input
voltage is outside this range, output may not be be available.
Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommendations are for a dedicated circuit sized for the rated output and duty cycle of the welding power source.
In dedicated circuit installations, the National Electrical Code (NEC) allows the receptacle or conductor rating to be less than the rating
of the circuit protection device. All components of the circuit must be physically compatible. See NEC articles 210.21, 630.11, and
630.12.
Single-Phase
Input Voltage (V)
208
230
400
460
575
Input Amperes (A) At Rated Output
60.8
54.6
29.7
25.4
19.9
Time-Delay Fuses 2
70
60
35
30
25
Normal Operating Fuses 3
80
80
45
40
30
Min Input Conductor Size In AWG/Kcmil 4
8
8
10
12
12
72
(22)
89
(27)
176
(54)
140
(43)
219
(67)
8
8
10
12
12
Input Voltage (V)
208
230
400
460
575
Input Amperes (A) At Rated Output
40.4
36.1
20.6
17.8
14.1
Time-Delay Fuses 2
45
40
25
20
15
Normal Operating Fuses 3
60
50
30
25
20
Max Recommended Standard Fuse Rating In Amperes 1
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG/Kcmil 4
Three-Phase
Max Recommended Standard Fuse Rating In Amperes 1
Min Input Conductor Size In AWG/Kcmil 4
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG/Kcmil 4
8
10
12
14
14
119
(36)
96
(29)
175
(53)
150
(46)
234
(71)
10
10
12
14
14
Reference: 2011 National Electrical Code (NEC) (including article 630)
1 If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse.
2 “Time-Delay” fuses are UL class “RK5” . See UL 248.
3 “Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amps), and UL class “H” ( 65 amps and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.15(B)(16). If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.
OM-252 340 Page 17
5-8. Connecting 1-Phase Input Power
1
8
=GND/PE Earth Ground
10
7
9
L1
L2
1
3
1
2
6
3
6
5
4
Tools Needed:
Ref. 804 532-A input 2012−05 − 803 766-C
OM-252 340 Page 18
5-8. Connecting 1-Phase Input Power (Continued)
!
!
Installation must meet all National and
Local Codes − have only qualified persons make this installation.
Disconnect and lockout/tagout input
power before connecting input conductors from unit. Follow established
procedures regarding the installation
and removal of lockout/tagout devices.
nected to any input power between 208 and
575 VAC without removing cover to relink the
power source.
See rating label on unit and check input voltage available at site.
7
8
9
Disconnect Device (switch shown in the
OFF position)
Disconnect Device Grounding Terminal
Disconnect Device Line Terminals
Connect green or green/yellow grounding
conductor to disconnect device grounding terminal first.
1
Black And White Input Conductor (L1
And L2)
2
Red Input Conductor
Connect input conductors L1 and L2 to disconnect device line terminals.
Always connect green or green/yellow
conductor to supply grounding terminal first, and never to a line terminal.
3
Green Or Green/Yellow Grounding
Conductor
10 Over-Current Protection
4
Insulation Sleeving
NOTICE − The Auto-Line circuitry in this unit
automatically adapts the power source to the
primary voltage being applied. Check input
voltage available at site. This unit can be con-
5
Electrical Tape
!
Insulate and isolate red conductor as shown.
6
Input Power Cord.
Select type and size of over-current protection
using Section 5-7 (fused disconnect switch
shown).
Close and secure door on disconnect device.
Follow established lockout/tagout procedures
to put unit in service.
input1 2012−05
Notes
Work like a Pro!
Pros weld and cut
safely. Read the
safety rules at
the beginning
of this manual.
OM-252 340 Page 19
5-9. Connecting 3-Phase Input Power
3
= GND/PE Earth Ground
4
7
2
L1
3
L2
5
L3
6
1
Tools Needed:
Ref. 804 532-A / input 2012−05 − 803 766-C
OM-252 340 Page 20
5-9. Connecting 3-Phase Input Power (Continued)
!
!
!
Installation must meet all National and
Local Codes − have only qualified persons make this installation.
Disconnect and lockout/tagout input
power before connecting input conductors from unit. Follow established
procedures regarding the installation
and removal of lockout/tagout
devices.
Always connect green or green/yellow
conductor to supply grounding terminal first, and never to a line terminal.
NOTICE − The Auto-Line circuitry in this unit
automatically adapts the power source to the
primary voltage being applied. Check input
voltage available at site. This unit can be connected to any input power between 208 and
575 VAC without removing cover to relink the
power source.
See rating label on unit and check input voltage available at site.
5
Input Conductors (L1, L2 And L3)
6
Disconnect Device Line Terminals
Connect green or green/yellow grounding
conductor to disconnect device grounding terminal first.
For Three-Phase Operation
Connect input conductors L1, L2, and L3 to
disconnect device line terminals.
1
Input Power Cord.
7
2
Disconnect Device (switch shown in the
OFF position)
Select type and size of over-current protection using Section 5-7 (fused disconnect
switch shown).
3
Green Or Green/Yellow Grounding
Conductor
4
Disconnect Device Grounding Terminal
Over-Current Protection
Close and secure door on disconnect device.
Follow established lockout/tagout procedures
to put unit in service.
input2 2012−05
Notes
Work like a Pro!
Pros weld and cut
safely. Read the
safety rules at
the beginning
of this manual.
OM-252 340 Page 21
‘
5-10.
Optional Gas Valve Operation And Shielding Gas Connection
Obtain gas cylinder and chain to
running gear, wall, or other stationary support so cylinder cannot fall
and break off valve.
4
1
Cylinder
2
Regulator/Flowmeter
Install so face is vertical.
3
GAS IN
Gas Hose Connection
Fitting has 5/8-18 right-hand
threads. Obtain and install gas
hose.
2
4
Gas In Fitting
5
Gas Out Fitting
The Gas In and Gas Out fittings
have 5/8-18 right-hand threads.
Obtain proper size, type, and length
hose and make connections as follows:
Connect hose from shielding gas
supply regulator/flowmeter to Gas
In fitting.
Connect hose coupler to torch.
Connect one end of gas hose to
hose coupler. Connect remaining
end of gas hose to Gas Out fitting.
Operation
3
1
The gas solenoid controls gas flow
during the TIG process as follows:
Lift−Arc TIG
Gas flow starts when tungsten
touches work (touch sensed).
Gas flow stops at end of post−flow.
Scratch Start TIG
Gas flow starts when current is detected.
Gas flow stops at end of post−flow.
5
Post−flow time is factory set to 5
seconds per 100 amps of weld current. The minimum post−flow time
is 5 seconds. The maximum post−
flow is 20 seconds (post flow settings are not adjustable by the end
user).
GAS OUT
Ref. 803 728-B / 804 533-A
OM-252 340 Page 22
SECTION 6 − OPERATION
6-1. Front Panel Controls
1
Power Switch
. The
fan motor is thermostatically
controlled and only runs when cooling is
needed.
Mode switch setting determines both the process and output On/Off control (see Section
6-3).
2
Voltmeter
For Air Carbon Arc (CAC-A) cutting and gouging, place switch in Stick position. For best results, place Arc Control in the maximum position.
3
Ammeter
6
4
V/A (Voltage/Amperage) Adjustment
Control
5
Mode Switch
Control adjusts Dig when Stick mode is selected on mode switch. When set at minimum,
short-clearing amperage at low arc voltage is
the same as normal welding amperage.
Arc Control
2
When set at maximum, short-clearing amperage is increased at low arc voltage to assist
with arc starts as well as reduce sticking while
welding.
Select setting best suited for application.
Control adjusts inductance when MIG or
FCAW − no gas is selected on the mode
switch. Inductance (0−100%) determines the
“wetness” of the weld puddle. When set towards maximum, “wetness” (puddle fluidity)
increases.
When one of the TIG modes is selected, this
control is not functional.
3
4
5
6
1
Ref. 803 727-B / Ref. 252 183-B
OM-252 340 Page 23
6-2. Meter Functions
. The meters display the actual weld output values for approximately three seconds after the arc is broken.
Mode
Meter Reading At Idle
V
Scratch
Start TIG
Lift-Arc TIG
71.7
A
85
10.3
A
85
Preset Amps
Actual Volts
Actual Amps
V
A
V
A
13.6
85
10.3
85
Preset Volts
Preset Amps
Actual Volts
Actual Amps
V
A
V
A
85
24.5
85
Actual Volts (OCV)
Preset Amps
Actual Volts
Actual Amps
V
A
V
A
24.5
250
Blank
Actual Volts
Actual Amps
24.5
MIG
V
Actual Volts (OCV)
71.7
Stick
Meter Reading While Welding
Preset Volts
6-3. Mode Switch Settings
. Stick mode provides the Adaptive Hot Start™ feature, which automatically increases the output amperage at the start of a weld should the start
require it. This eliminates electrode sticking at arc start.
Mode Switch Setting
Process
Output Control
Scratch Start TIG
GTAW
Electrode Hot
Lift-Arc TIG
GTAW − See Section 6-4
Electrode Hot
Stick
SMAW
Electrode Hot
FCAW (no gas)
FCAW (no gas)
At Wire Feeder
MIG/FCAW (with gas)
FCAW/GMAW
At Wire Feeder
. On non-WCC power source output (V) is controlled at the power source.
OM-252 340 Page 24
6-4. Lift-Arc TIG Procedure
With Process Switch in the Lift-Arc
TIG position, start an arc as follows:
1
TIG Electrode
2
Workpiece
Touch tungsten electrode to workpiece at weld start point, hold
electrode to workpiece for 1-2
seconds, and slowly lift electrode.
An arc will form when electrode is
lifted.
1
“Touch”
2
1−2
Seconds
Normal open-circuit voltage is not
present before tungsten electrode
touches workpiece; only a low
sensing voltage is present between
electrode and workpiece. The
solid-state output contactor does
not energize until after electrode is
touching workpiece. This allows
electrode to touch workpiece without overheating, sticking, or getting
contaminated.
. Association with a WCC feeder
will not occur in LIFT ARC TIG
mode.
Do NOT Strike Like A Match!
Ref. S-156 279
6-5.
Optional Low Open Circuit Voltage (OCV) Welding Modes
Low OCV Operation
The unit can be optionally configured for low open circuit voltage
(OCV) operation in Stick and
Scratch Start TIG modes. When the
unit is configured for low OCV operation only a low sensing voltage
(approximately 15 VDC) is present
between the electrode and the
workpiece prior to the electrode
touching the workpiece. Consult a
Factory Authorized Service Agent
for information regarding how to
configure the unit for low OCV welding operation.
. Low OCV mode will not function
with WCC feeder.
OM-252 340 Page 25
SECTION 7 − MAINTENANCE & TROUBLESHOOTING
7-1. Routine Maintenance
!
Disconnect power
before maintaining.
. Maintain more often
during severe conditions.
3 Months
Repair Or
Replace
Cracked
Cables
Replace
Damaged Or
Unreadable
Labels
Replace Cracked
Torch Body
Repair Or Replace
Cracked Cables
And Cords
Clean
And
Tighten Weld
Connections
6 Months
Blow Out Inside
7-2. Blowing Out Inside Of Unit
!
Do not remove case when
blowing out inside of unit.
To blow out unit, direct airflow
through front and back louvers as
shown.
803 728-B
OM-252 340 Page 26
7-3. Help Displays
. All directions are in reference to the
front of the unit. All circuitry referred
to is located inside the unit.
V
A
Help 1 Display
HE.L P−1
V
A
HE.L P−2
V
A
HE.L P−3
V
A
HE.L P−5
V
A
HE.L P−6
V
A
Indicates a malfunction in the primary power
circuit. If this display is shown, contact a Factory Authorized Service Agent.
Help 2 Display
Indicates a malfunction in the thermal protection circuitry. If this display is shown, contact
a Factory Authorized Service Agent.
Help 3 Display
Indicates the left side of the unit has overheated. The unit has shut down to allow the
fan to cool it (see Section 4-3). Operation will
continue when the unit has cooled.
Help 5 Display
Indicates the right side of the unit has overheated. The unit has shut down to allow the
fan to cool it (see Section 4-3). Operation will
continue when the unit has cooled.
Help 6 Display
Indicates operation at maximum input current. The unit has a maximum allowable input
current limit. As the line voltage decreases,
the required input current increases. If the line
voltage is too low, the output power is limited
by the input current. When this limit is
reached, the unit automatically reduces output power to continue operation. If this display
is shown, have a qualified electrician check
the input voltage.
Help 8 Display
HE.L P−8
V
A
Indicates a malfunction in the secondary
power circuit of the unit. If this display is
shown, contact a Factory Authorized Service
Agent.
Process Display
PrO CES
Indicates unknown process, turn process select switch to align with tick mark.
7-4. Troubleshooting
Trouble
No weld output; unit completely inoperative.
Remedy
Place line disconnect switch in On position (see Sections 5-8and 5-9).
Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section5-8and 5-9).
Check for proper input power connections (see Section 5-8 and 5-9).
No weld output; meter display On.
Input voltage outside acceptable range of variation (see Section 5-7).
Unit overheated. Allow unit to cool with fan On (see Section 4-3).
Erratic or improper weld output.
Use proper size and type of weld cable (see Section 5-6).
Clean and tighten all weld connections.
Check for correct polarity.
Unit will not associate.
Check mode switch position on power source. Association will not occur in LIFT ARC TIG mode.
OM-252 340 Page 27
SECTION 8 − ELECTRICAL DIAGRAM
Figure 8-1. Circuit Diagram
OM-252 340 Page 28
251 574-A
OM− 252 340 Page 29
OM-252 340 Page 30
69
4
3
1
79
5
Figure 9-1. Parts Assembly
68
64
62
67
66
2
6
65
61
8
57
60
59
9
63
58
56
70
12
7 10
57
11
52
56
71
13
51
55
72
54
16
15
17
14
53
48
47
50
20
80
46
45
21
19
18
44
75
22
23
76
49
73
77
MOD 1
25
40
MOD 2
22
42
78
43
74
24
32
27
37
38
36
35
34
33
26
43
39
28
16
41
31
30
29
SECTION 9 − PARTS LIST
Ref. 258 057-B
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 9-1. Parts Assembly
. . . 1 . . . . . . . . . . . . . . . 216 034 . . Wrapper (Includes Insulators and Safety Labels) . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 175 256 . . Insulator, Side Rh (Not Shown) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 178 551 . . Insulator, Side (Not Shown) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 2 . . . . . . . . . . . . . . . 134 327 . . Label, Warning General Precautionary Static & Wire Feed . . . . . . . . . . .
. . . 3 . . . . . . . . . . . . . . . 138 442 . . Label, Caution Falling Equipment Can Cause Injury . . . . . . . . . . . . . . . .
. . . 4 . . . . . . . . . . . . . . . 208 015 . . Handle, Rubberized Carrying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 5 . . . . . . . . . . . . . . . 135 483 . . Label, Important Remove These Two Handle Screws . . . . . . . . . . . . . . .
. . . 6 . . . . R3/C4 . . . . 233 052 . . Resistor/Capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 7 . . . . . SR1 . . . . . 201 530 . . Kit, Diode Fast Recovery Bridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 8 . . . . . . . . . . . . . . . 199 840 . . Bus Bar, Diode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 9 . . . . . . . . . . . . . . . 196 355 . . Insulator, Screw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 10 . . . . D1,D2 . . . . 201 531 . . Kit, Diode Power Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 11 . . . . . RT1 . . . . . 199 798 . . Thermistor, NTC 30K Ohm @ 25 Deg C 18in Lead . . . . . . . . . . . . . . . . .
. . . 12 . . . . . CR1 . . . . . 255 744 . . Relay, Encl 24vdc Spst 30a/300vac 4pin Flange Mtg . . . . . . . . . . . . . . . .
. . . 13 . . . . . . . . . . . . . . . 227 127 . . Label, Warning Electric Shock/Exploding Parts . . . . . . . . . . . . . . . . . . . . .
. . . 14 . . . . . . . . . . . . . . . 010 546 . . Bushing, Snap-In Nyl .375 Id X .500 Mtg Hole . . . . . . . . . . . . . . . . . . . . .
. . . 15 . . . . . . L4 . . . . . . 218 020 . . Inductor, Boost . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 16 . . . . . . . . . . . . . . . 179 276 . . Bushing, Snap-In Nyl 1.000 Id X 1.375 Mtg Hole Cent . . . . . . . . . . . . . .
. . . 17 . . . . . . . . . . . . . . . 170 647 . . Bushing, Snap-In Nyl 1.312 Id X 1.500 Mtg Hole . . . . . . . . . . . . . . . . . . .
. . . 18 . . . . . . L3 . . . . . . 251 396 . . Inductor, Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 19 . . . . . . T1 . . . . . . 251 394 . . XFMR, HF Litz/Litz W/Boost . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 20 . . . . . . . . . . . . . . . 225 097 . . Heat Sink, Lh Rect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 21 . . . . . . L1 . . . . . . 212 091 . . Inductor, Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 22 . . . . . . . . . . . . . . . 083 147 . . Grommet, Scr No 8/10 Panel Hole .312 Sq .500 High . . . . . . . . . . . . . . .
. . . 23 . . . . . PC1 . . . . . 242 348 . . Circuit Card Assy, Control W/Program . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 216 113 . . Stand-Off Support, PC Card .187 Dia W/P&l .375 . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG1 . . . . 115 091 . . Housing Plug+Pins (Service Kit) RC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG2 . . . . 201 665 . . Housing Plug+Pins (Service Kit) RC2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG3 . . . . 131 056 . . Housing Plug+Pins (Service Kit) RC3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG7 . . . . 131 054 . . Housing Plug+Pins (Service Kit) RC7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG8 . . . . 131 054 . . Housing Plug+Pins (Service Kit) RC8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG9 . . . . 115 093 . . Housing Plug+Pins (Service Kit) RC9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG10 . . . . 115 094 . . Housing Plug+Pins (Service Kit) RC10 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG11 . . . . 115 094 . . Housing Plug+Pins (Service Kit) RC11 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 24 . . . . . . . . . . . . . . . 212 072 . . Bracket, Mtg Capacitor/PC Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 25 . . . . C12,13 . . . . 219 930 . . Kit, Capacitor Elctlt Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 26 . . . . . . . . . . . . . . +212 203 . . Panel, Rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 27 . . . . . . . . . . . . . . . 126 026 . . Label, Warning Electric Shock Can Kill Significant . . . . . . . . . . . . . . . . . .
. . . 28 . . . . . . . . . . . . . . . . . . . . . . . . . . Nameplate, Rear (Order by Model and Serial Number) . . . . . . . . . . . . . .
. . . 29 . . . . . . . . . . . . . . . 217 480 . . Label, Warning Incorrect Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 30 . . . . . . . . . . . . . . . 215 980 . . Bushing, Strain Relief .709/.984 Id X1.375 Mtg Hole . . . . . . . . . . . . . . . .
. . . 31 . . . . . . . . . . . . . . . 219 487 . . Cable, Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 32 . . . . . . . . . . . . . . . 234 126 . . Nut, Conduit 1.000 Npt Knurled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 33 . . . . . . L2 . . . . . . 218 018 . . Inductor, Pre-Regulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 34 . . . . . . . . . . . . . . . 218 566 . . Gasket, Inductor Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 35 . . . . . CT1 . . . . . 196 231 . . XMFR, Current Sensing 200/1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 36 . . . . . C15 . . . . . 196 143 . . Capacitor, Polyp Met Film 16. Uf 400 VAC 10% . . . . . . . . . . . . . . . . . . . .
. . . 37 . . . . . . . . . . . . . . . 216 117 . . Bracket, Mtg Capacitor Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 38 . . . . . RT2 . . . . . 199 798 . . Thermistor, NTC 30K Ohm @ 25 Deg C 18in Lead . . . . . . . . . . . . . . . . .
. . . 39 . . . . . PC2 . . . . . 225 442 . . Circuit Card Assy, Interconnect W/Label & Clips (Includes) . . . . . . . . . .
. . . 40 . . . . . . . . . . . . . . . 126 026 . . . . Label, Warning Electric Shock Can Kill Significant . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 223 343 . . . . Clip, Wire Stdf .40−.50 Bndl .156Hole .031−.078Thk . . . . . . . . . . . . . .
. . . . . . . . . . PLG13 . . . . 130 203 . . Housing Plug+Pins (Service Kit) RC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG14 . . . . 201 665 . . Housing Plug+Pins (Service Kit) RC2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG15 . . . . 115 092 . . Housing Plug+Pins (Service Kit) RC3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG20 . . . . 115 093 . . Housing Plug+Pins (Service Kit) RC6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 41 . . . . . . . . . . . . . . . 153 403 . . Bushing, Snap-In Nyl .750 Id X 1.000 Mtg Hole Cent . . . . . . . . . . . . . . . .
. . . 42 . . . . . RM1 . . . . . 205 751 . . Module, Power Resistor W/Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 43 . . . . . . . . . . . . . . . 217 625 . . Kit, Input/Pre-Regulator And Inverter Module (Includes) . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MOD 1, SKiip 83 HEC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MOD 2, SKiip 83 EC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 44 . . . . . . . . . . . . . . . 212 206 . . Windtunnel, Rh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 45 . . . . . . . . . . . . . . . 196 330 . . Heat Sink, Power Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 46 . . . . . . . . . . . . . . +175 132 . . Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
2
2
2
2
1
1
2
4
2
1
1
1
1
1
3
1
1
1
1
1
8
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
2
1
1
1
1
1
1
1
OM-252 340 Page 31
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 9-1. Parts Assembly (Continued)
. . . 47 . . . . . . . . . . . . . . . 229 325 . . Foot, Mtg Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 48 . . . . . . . . . . . . . . . 176 736 . . Screw, Mtg Foot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 49 . . . . . . . . . . . . . . . 153 178 . . Label, Warning Exploding Parts Can Serious Injury . . . . . . . . . . . . . . . . .
. . . 50 . . . . . . . . . . . . . . . 212 074 . . Bus Bar, Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 51 . . . . . HD1 . . . . . 182 918 . . Transducer, Current 400A Module Supply V +/− 15V . . . . . . . . . . . . . . . .
. . . 52 . . . . . PC3 . . . . . 252 312 . . Circuit Card Assy, Front Panel & Display W/Program WCC . . . . . . . . . .
. . . . . . . . . . PLG18 . . . . 131 204 . . Housing Plug+Pins (Service Kit) RC2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . PLG 19 . . . 131 055 . . Housing Rcpt+Skts, (Service Kit) RC3 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 53 . . . . . . S1 . . . . . 244 920 . . Switch, Tgl 3Pst 40A 600VAC Scr Term Wide Tgl . . . . . . . . . . . . . . . . . .
. . . 54 . . . . . . . . . . . . . . . 176 226 . . Insulator, Switch Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 55 . . . . . FM1 . . . . . 196 313 . . Fan, Muffin 115V 50/60Hz 3000 RPM 6.378 Mtg Holes . . . . . . . . . . . . . .
. . . . . . . . . . PLG16 . . . . 131 054 . . Housing Plug+Pins (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . RC16 . . . . 135 635 . . Housing Plug+Pins (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 56 . . . . . . . . . . . . . . . 258 713 . . Rcpt Assy, Tw Lk Insul Fem (Tweco) Bolted (Includes) . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 250 040 . . Receptacle, Twist Lock Tweco .890 OD Bolted . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 250 037 . . . . Insulator, Bulkhead Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 250 039 . . . . Insulator, Bulkhead Rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 185 714 . . . . Washer, Tooth 22mmid X 31.5mmod 1.310-1mmt Intern . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 185 717 . . . . Nut, M20-1.5 1.00hex .19h Brs Locking . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 185 718 . . . . O-Ring, 0.989 Id X 0.070 H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 186 228 . . . . O-Ring, 0.739 Id X 0.070 H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 178 548 . . . . Terminal, Connector Friction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 57 . . . . . . . . . . . . . . . 258 712 . . Rcpt Assy, Tw Lk Insul Fem (Tweco) (Includes) . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 250 041 . . Receptacle, Twist Lock Tweco .890 OD . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 250 037 . . . . Insulator, Bulkhead Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 250 039 . . . . Insulator, Bulkhead Rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 185 714 . . . . Washer, Tooth 22mmid X 31.5mmod 1.310-1mmt Intern . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 185 717 . . . . Nut, M20-1.5 1.00hex .19h Brs Locking . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 185 718 . . . . O-Ring, 0.989 Id X 0.070 H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 186 228 . . . . O-Ring, 0.739 Id X 0.070 H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 178 548 . . . . Terminal, Connector Friction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 58 . . . . . . . . . . . . . . . 247 557 . . Panel, Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 59 . . . . . C6,7 . . . . . 214 749 . . Capacitor Assy, W/Plug & Leads (Voltage Feedback) . . . . . . . . . . . . . . .
. . . 60 . . . . . . . . . . . . . . . 216 112 . . Fastener, Panel Receptacle Quick Access . . . . . . . . . . . . . . . . . . . . . . . .
. . . 61 . . . . . . . . . . . . . . . . . . . . . . . . . . Nameplate (Order by Model and Serial Number) . . . . . . . . . . . . . . . . . . .
. . . 62 . . . . . . . . . . . . . . . . . . . . . . . . . . Nameplate, Connection (Order by Model and Serial Number) . . . . . . . .
. . . 63 . . . . . . . . . . . . . . . . . . . . . . . . . . Nameplate, Power (Order by Model and Serial Number) . . . . . . . . . . . . .
. . . 64 . . . . . . . . . . . . . . . 174 991 . . Knob, Pointer 1.250 Dia X .250 Id W/Spring Clip−.21 . . . . . . . . . . . . . . .
. . . 65 . . . . . . . . . . . . . . . 174 992 . . Knob, Pointer .840 Dia X .250 Id W/Spring Clip-.21 . . . . . . . . . . . . . . . . .
. . . 66 . . . . . . . . . . . . . . . 257 717 . . Label, Process XMT 350 VS W/WCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 67 . . . . . . . . . . . . . . . 218 041 . . Door, W/Quick Access Ball Fasteners . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 68 . . . . . . . . . . . . . . . 175 138 . . Box, Louver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 69 . . . . . . . . . . . . . . . . . . . . . . . . . . Label, (Order By Model And Serial Number) . . . . . . . . . . . . . . . . . . . . . . .
. . . 70 . . . . . . . . . . . . . . +212 207 . . Windtunnel, Lh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 71 . . . . . . . . . . . . . . . 211 503 . . Insulator, Heat Sink . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 72 . . . . . . . . . . . . . . . 227 746 . . Gasket, Inductor Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 73 . . . . . . . . . . . . . . . 024 376 . . Blank, Snap−In Nyl .625 Mtg Hole Black . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 74 . . . . . . . . . . . . . . . 107 983 . . Blank, Snap−In Nyl .500 Mtg Hole Black . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 75 . . . . . . L8 . . . . . . 241 027 . . Core, Toroidal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 76 . . . . . PC4 . . . . . 252 316 . . Circuit Card Assy, XMT WCC Control W/Prgm . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . PLG 22 . . . 130 203 . . Housing Plug+Skts, (Service Kit) J1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . PLG 23 . . . 131 204 . . Housing Plug+Skts, (Service Kit) J2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . PLG 21 . . . 131 055 . . Housing Plug+Skts, (Service Kit) RC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 77 . . . . . . . . . . . . . . . 252 337 . . Bracket, Mtg WCC Control Bd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 78 . . . . . PC5 . . . . . 252 530 . . Module, WCC DX Series Resonant Coupler Module . . . . . . . . . . . . . . . .
. . . . . . . . . PLG 17 . . . 202 592 . . Housing Rcpt+Skts, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . RC 17 . . . . 258 084 . . Housing Plug+Pins, (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 245 663 . . Instruction, Burn-in Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 79 . . . . . . . . . . . . . . . 245 663 . . Knob, Encoder 1.250 Dia X .250 Id Push On W/Spring . . . . . . . . . . . . . .
. . . 80 . L9, L10, L11 . 194 254 . . Core, Toroidal 22.25mm ID X 36.96mm OD X 15.88mm . . . . . . . . . . . . .
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
BE SURE TO PROVIDE MODEL AND SERIAL NUMBER WHEN ORDERING REPLACEMENT PARTS.
OM-252 340 Page 32
4
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
2
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
Notes
Notes
Effective January 1, 2012
(Equipment with a serial number preface of MC or newer)
Warranty Questions?
Call
1-800-4-A-MILLER
for your local
Miller distributor.
Your distributor also gives
you ...
Service
You always get the fast,
reliable response you
need. Most replacement
parts can be in your
hands in 24 hours.
Support
Need fast answers to the
tough welding questions?
Contact your distributor.
The expertise of the
distributor and Miller is
there to help you, every
step of the way.
This limited warranty supersedes all previous Miller warranties and is exclusive with no other
guarantees or warranties expressed or implied.
LIMITED WARRANTY − Subject to the terms and conditions 6. 90 Days — Parts
below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants to its
* Accessory (Kits)
original retail purchaser that new Miller equipment sold after the
* Canvas Covers
effective date of this limited warranty is free of defects in material
* Induction Heating Coils and Blankets, Cables, and
and workmanship at the time it is shipped by Miller. THIS
Non-Electronic Controls
WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER
* M-Guns
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE
* MIG Guns and Subarc (SAW) Guns
WARRANTIES OF MERCHANTABILITY AND FITNESS.
* Remote Controls and RFCS-RJ45
Within the warranty periods listed below, Miller will repair or replace
* Replacement Parts (No labor)
any warranted parts or components that fail due to such defects in
* Roughneck Guns
material or workmanship. Miller must be notified in writing within
thirty (30) days of such defect or failure, at which time Miller will
* Spoolmate Spoolguns
provide instructions on the warranty claim procedures to be
followed.
Miller shall honor warranty claims on warranted equipment listed
below in the event of such a failure within the warranty time
periods. All warranty time periods start on the delivery date of the
equipment to the original end-user purchaser, and not to exceed
one year after the equipment is shipped to a North American
distributor or eighteen months after the equipment is shipped to an
International distributor.
1.
2.
3.
4.
5.
5 Years Parts — 3 Years Labor
* Original Main Power Rectifiers Only to Include SCRs,
Diodes, and Discrete Rectifier Modules
3 Years — Parts and Labor
* Engine Driven Welding Generators
(NOTE: Engines are Warranted Separately by the
Engine Manufacturer.)
* Inverter Power Sources (Unless Otherwise Stated)
* Plasma Arc Cutting Power Sources
* Process Controllers
* Semi-Automatic and Automatic Wire Feeders
* Smith 30 Series Flowgauge and Flowmeter
Regulators (No Labor)
* Transformer/Rectifier Power Sources
* Water Coolant Systems (Integrated)
2 Years — Parts
* Auto-Darkening Helmet Lenses (No Labor)
1 Year — Parts and Labor Unless Specified
* Automatic Motion Devices
* CoolBelt and CoolBand Blower Unit (No Labor)
* External Monitoring Equipment and Sensors
* Field Options
(NOTE: Field options are covered for the remaining
warranty period of the product they are installed in, or
for a minimum of one year — whichever is greater.)
* Flowgauge and Flowmeter Regulators (No Labor)
* RFCS Foot Controls (Except RFCS-RJ45)
* Fume Extractors
* HF Units
* ICE/XT Plasma Cutting Torches (No Labor)
* Induction Heating Power Sources, Coolers
(NOTE: Digital Recorders are Warranted
Separately by the Manufacturer.)
* Load Banks
* Motor Driven Guns (w/exception of Spoolmate
Spoolguns)
* PAPR Blower Unit (No Labor)
* Positioners and Controllers
* Racks
* Running Gear/Trailers
* Spot Welders
* Subarc Wire Drive Assemblies
* Water Coolant Systems (Non-Integrated)
* Weldcraft-Branded TIG Torches (No Labor)
* Wireless Remote Foot/Hand Controls and Receivers
* Work Stations/Weld Tables (No Labor)
6 Months — Parts
* Batteries
* Bernard Guns (No Labor)
* Tregaskiss Guns (No Labor)
Miller’s True Blue® Limited Warranty shall not apply to:
1.
2.
3.
Consumable components; such as contact tips,
cutting nozzles, contactors, brushes, relays, work
station table tops and welding curtains, or parts that
fail due to normal wear. (Exception: brushes and
relays are covered on all engine-driven products.)
Items furnished by Miller, but manufactured by others,
such as engines or trade accessories. These items are
covered by the manufacturer’s warranty, if any.
Equipment that has been modified by any party other than
Miller, or equipment that has been improperly installed,
improperly operated or misused based upon industry
standards, or equipment which has not had reasonable
and necessary maintenance, or equipment which has
been used for operation outside of the specifications for
the equipment.
MILLER PRODUCTS ARE INTENDED FOR PURCHASE AND
USE BY COMMERCIAL/INDUSTRIAL USERS AND PERSONS
TRAINED AND EXPERIENCED IN THE USE AND
MAINTENANCE OF WELDING EQUIPMENT.
In the event of a warranty claim covered by this warranty, the
exclusive remedies shall be, at Miller’s option: (1) repair; or (2)
replacement; or, where authorized in writing by Miller in
appropriate cases, (3) the reasonable cost of repair or
replacement at an authorized Miller service station; or (4) payment
of or credit for the purchase price (less reasonable depreciation
based upon actual use) upon return of the goods at customer’s risk
and expense. Miller’s option of repair or replacement will be F.O.B.,
Factory at Appleton, Wisconsin, or F.O.B. at a Miller authorized
service facility as determined by Miller. Therefore no
compensation or reimbursement for transportation costs of any
kind will be allowed.
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR
DIRECT,
INDIRECT,
SPECIAL,
INCIDENTAL
OR
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF
PROFIT), WHETHER BASED ON CONTRACT, TORT OR ANY
OTHER LEGAL THEORY.
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND
ANY
IMPLIED
WARRANTY,
GUARANTY
OR
REPRESENTATION AS TO PERFORMANCE, AND ANY
REMEDY FOR BREACH OF CONTRACT TORT OR ANY
OTHER LEGAL THEORY WHICH, BUT FOR THIS PROVISION,
MIGHT ARISE BY IMPLICATION, OPERATION OF LAW,
CUSTOM OF TRADE OR COURSE OF DEALING, INCLUDING
ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR PARTICULAR PURPOSE, WITH RESPECT TO
ANY AND ALL EQUIPMENT FURNISHED BY MILLER IS
EXCLUDED AND DISCLAIMED BY MILLER.
Some states in the U.S.A. do not allow limitations of how long an
implied warranty lasts, or the exclusion of incidental, indirect,
special or consequential damages, so the above limitation or
exclusion may not apply to you. This warranty provides specific
legal rights, and other rights may be available, but may vary from
state to state.
In Canada, legislation in some provinces provides for certain
additional warranties or remedies other than as stated herein, and
to the extent that they may not be waived, the limitations and
exclusions set out above may not apply. This Limited Warranty
provides specific legal rights, and other rights may be available,
but may vary from province to province.
miller_warr 2012-01
Owner’s Record
Please complete and retain with your personal records.
Model Name
Serial/Style Number
Purchase Date
(Date which equipment was delivered to original customer.)
Distributor
Address
City
State
Zip
For Service
Contact a DISTRIBUTOR or SERVICE AGENCY near you.
Always provide Model Name and Serial/Style Number.
Contact your Distributor for:
Welding Supplies and Consumables
Options and Accessories
Personal Safety Equipment
Service and Repair
Miller Electric Mfg. Co.
An Illinois Tool Works Company
1635 West Spencer Street
Appleton, WI 54914 USA
Replacement Parts
Training (Schools, Videos, Books)
Technical Manuals (Servicing Information
and Parts)
Circuit Diagrams
For International Locations Visit
www.MillerWelds.com
Welding Process Handbooks
To locate a Distributor or Service Agency visit
www.millerwelds.com or call 1-800-4-A-Miller
Contact the Delivering Carrier to:
File a claim for loss or damage during
shipment.
For assistance in filing or settling claims, contact
your distributor and/or equipment manufacturer’s
Transportation Department.
ORIGINAL INSTRUCTIONS − PRINTED IN USA
International Headquarters−USA
USA Phone: 920-735-4505 Auto-Attended
USA & Canada FAX: 920-735-4134
International FAX: 920-735-4125
© 2012 Miller Electric Mfg. Co.
2012−01

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project