OM-257486E
2016-06
Processes
Multiprocess Welding
Description
Arc Welding Power Source
R
XMT 425 CC/CV
Auto-Line CE
™
For product information,
Owner’s Manual translations,
and more, visit
www.MillerWelds.com
File: MULTIPROCESS
From Miller to You
Thank you and congratulations on choosing Miller. Now you can get the
job done and get it done right. We know you don’t have time to do it any
other way.
That’s why when Niels Miller first started building arc welders in 1929,
he made sure his products offered long-lasting value and superior quality.
Like you, his customers couldn’t afford anything less. Miller products had
to be more than the best they could be. They had to be the best you could
buy.
Today, the people that build and sell Miller products continue the
tradition. They’re just as committed to providing equipment and service
that meets the high standards of quality and value established in 1929.
This Owner’s Manual is designed to help you get the most out of your
Miller products. Please take time to read the Safety precautions. They will
help you protect yourself against potential hazards on the worksite. We’ve
made installation and operation quick and easy. With Miller you can
count on years of reliable service with proper maintenance. And if for
some reason the unit needs repair, there’s a Troubleshooting section that
will help you figure out what the problem is. The parts list will then help
you to decide which exact part you may need to fix the problem.
Warranty and service information for your particular model are also
provided.
Miller Electric manufactures a full line of
welders and welding related equipment. For
information on other quality Miller products, contact your local Miller
distributor to receive the latest full line catalog or individual catalog sheets.
Working as hard as you do
− every power source from
Miller is backed by the most
hassle-free warranty in the
business.
TABLE OF CONTENTS
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4. California Proposition 65 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-6. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 − DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1. Additional Safety Symbols And Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2. Miscellaneous Symbols And Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 − SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1. Serial Number And Rating Label Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2. Unit Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-3. Dimensions And Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-4. Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-5. Duty Cycle And Overheating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-6. Volt-Ampere Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 4 − INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-1. Selecting A Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. Selecting Cable Sizes* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3. Weld Output Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-4. Remote 14 Receptacle Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-5. Supplementary Protectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-6. Optional Gas Valve Operation And Shielding Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-7. Electrical Service Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-8. Connecting 3-Phase Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 5 − OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-1. Front Panel Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2. Meter Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-3. Mode Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-4. Lift-Arc Trigger Hold TIG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-5. Stick Start Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 − MAINTENANCE & TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-2. Blowing Out Inside Of Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-3. Voltmeter/Ammeter Help Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-4. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 7 − ELECTRICAL DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 8 − PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARRANTY
1
1
1
3
4
4
4
5
5
7
8
8
8
8
8
10
11
12
12
13
13
14
14
15
16
18
20
20
21
21
22
22
23
23
23
24
24
26
28
DECLARATION OF CONFORMITY
for European Community (CE marked) products.
ITW Welding Italy S.r.l Via Privata Iseo 6/E, 20098 San Giuliano M.se, (MI) Italy declares that the
product(s) identified in this declaration conform to the essential requirements and provisions of the
stated Council Directive(s) and Standard(s).
Product/Apparatus Identification:
Product
Stock Number
XMT 425 CC/CV AUTOLINE, CE
907557002
Council Directives:
•
2006/95/EC Low Voltage
•
2004/108/EC Electromagnetic Compatibility
•
2011/65/EU Restriction of the use of certain hazardous substances in electrical and electronic equipment
Standards:
•
IEC 60974-1:2012 Arc Welding Equipment - Part 1: Welding Power Sources
•
IEC 60974-10:2007 Arc Welding Equipment - Part 10: Electromagnetic Compatibility Requirements
EU Signatory:
July 10th, 2015
___________________________________________________________________________________
Massimigliano Lavarini
Date of Declaration
ITW WELDING ITALY PRODUCTION MANAGER
956 172 225
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING
som 2015−09
7
Protect yourself and others from injury — read, follow, and save these important safety precautions and operating instructions.
1-1. Symbol Usage
DANGER! − Indicates a hazardous situation which, if
not avoided, will result in death or serious injury. The
possible hazards are shown in the adjoining symbols
or explained in the text.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury. The possible
hazards are shown in the adjoining symbols or explained in the text.
NOTICE − Indicates statements not related to personal injury.
. Indicates special instructions.
This group of symbols means Warning! Watch Out! ELECTRIC
SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult symbols and related instructions below for necessary actions to avoid the
hazards.
1-2. Arc Welding Hazards
The symbols shown below are used throughout this manual
to call attention to and identify possible hazards. When you
see the symbol, watch out, and follow the related instructions
to avoid the hazard. The safety information given below is
only a summary of the more complete safety information
found in the Safety Standards listed in Section 1-5. Read and
follow all Safety Standards.
Only qualified persons should install, operate, maintain, and
repair this unit.
During operation, keep everybody, especially children, away.
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shocks
or severe burns. The electrode and work circuit is
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also
live when power is on. In semiautomatic or automatic
wire welding, the wire, wire reel, drive roll housing,
and all metal parts touching the welding wire are
electrically live. Incorrectly installed or improperly
grounded equipment is a hazard.
D Do not touch live electrical parts.
D Wear dry, hole-free insulating gloves and body protection.
D Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.
D Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
D Use AC output ONLY if required for the welding process.
D If AC output is required, use remote output control if present on
unit.
D Additional safety precautions are required when any of the following electrically hazardous conditions are present: in damp
locations or while wearing wet clothing; on metal structures such
as floors, gratings, or scaffolds; when in cramped positions such
as sitting, kneeling, or lying; or when there is a high risk of unavoidable or accidental contact with the workpiece or ground. For these
conditions, use the following equipment in order presented: 1) a
semiautomatic DC constant voltage (wire) welder, 2) a DC manual
(stick) welder, or 3) an AC welder with reduced open-circuit voltage. In most situations, use of a DC, constant voltage wire welder
is recommended. And, do not work alone!
D Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
D Properly install, ground, and operate this equipment according to
its Owner’s Manual and national, state, and local codes.
D Always verify the supply ground − check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
grounded receptacle outlet.
D When making input connections, attach proper grounding conductor first − double-check connections.
D Keep cords dry, free of oil and grease, and protected from hot metal
and sparks.
D Frequently inspect input power cord and ground conductor for
damage or bare wiring – replace immediately if damaged – bare
wiring can kill.
D Turn off all equipment when not in use.
D Do not use worn, damaged, undersized, or repaired cables.
D Do not drape cables over your body.
D If earth grounding of the workpiece is required, ground it directly
with a separate cable.
D Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
D Do not touch electrode holders connected to two welding machines at the same time since double open-circuit voltage will be
present.
D Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
D Wear a safety harness if working above floor level.
D Keep all panels and covers securely in place.
D Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
D Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
D Do not connect more than one electrode or work cable to any
single weld output terminal. Disconnect cable for process not in
use.
D Use GFCI protection when operating auxiliary equipment in damp
or wet locations.
SIGNIFICANT DC VOLTAGE exists in inverter welding power sources AFTER removal of input power.
D Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section
before touching any parts.
HOT PARTS can burn.
D Do not touch hot parts bare handed.
D Allow cooling period before working on
equipment.
D To handle hot parts, use proper tools and/or wear heavy, insulated welding gloves and clothing to prevent burns.
OM-257486 Page 1
FUMES AND GASES can be hazardous.
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health.
D Keep your head out of the fumes. Do not breathe the fumes.
D If inside, ventilate the area and/or use local forced ventilation at the
arc to remove welding fumes and gases. The recommended way
to determine adequate ventilation is to sample for the composition
and quantity of fumes and gases to which personnel are exposed.
D If ventilation is poor, wear an approved air-supplied respirator.
D Read and understand the Safety Data Sheets (SDSs) and the
manufacturer’s instructions for adhesives, coatings, cleaners,
consumables, coolants, degreasers, fluxes, and metals.
D Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watchperson nearby. Welding fumes and gases can displace air and
lower the oxygen level causing injury or death. Be sure the breathing air is safe.
D Do not weld in locations near degreasing, cleaning, or spraying operations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.
D Do not weld on coated metals, such as galvanized, lead, or
cadmium plated steel, unless the coating is removed from the weld
area, the area is well ventilated, and while wearing an air-supplied
respirator. The coatings and any metals containing these elements
can give off toxic fumes if welded.
ARC RAYS can burn eyes and skin.
Arc rays from the welding process produce intense
visible and invisible (ultraviolet and infrared) rays
that can burn eyes and skin. Sparks fly off from the
weld.
D Wear an approved welding helmet fitted with a proper shade of
filter lenses to protect your face and eyes from arc rays and
sparks when welding or watching (see ANSI Z49.1 and Z87.1
listed in Safety Standards).
D Wear approved safety glasses with side shields under your
helmet.
D Use protective screens or barriers to protect others from flash,
glare and sparks; warn others not to watch the arc.
D Wear body protection made from durable, flame−resistant material (leather, heavy cotton, wool). Body protection includes
oil-free clothing such as leather gloves, heavy shirt, cuffless
trousers, high shoes, and a cap.
WELDING can cause fire or explosion.
Welding on closed containers, such as tanks,
drums, or pipes, can cause them to blow up. Sparks
can fly off from the welding arc. The flying sparks, hot
workpiece, and hot equipment can cause fires and
burns. Accidental contact of electrode to metal objects can cause
sparks, explosion, overheating, or fire. Check and be sure the area is
safe before doing any welding.
D Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
D Do not weld where flying sparks can strike flammable material.
D Protect yourself and others from flying sparks and hot metal.
D Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
D Watch for fire, and keep a fire extinguisher nearby.
D Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
D Do not weld on containers that have held combustibles, or on
closed containers such as tanks, drums, or pipes unless they are
properly prepared according to AWS F4.1 and AWS A6.0 (see
Safety Standards).
D Do not weld where the atmosphere can contain flammable dust,
gas, or liquid vapors (such as gasoline).
D Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly
unknown paths and causing electric shock, sparks, and fire
hazards.
D Do not use welder to thaw frozen pipes.
OM- 257486 Page 2
D Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
D Wear body protection made from durable, flame−resistant material
(leather, heavy cotton, wool). Body protection includes oil-free
clothing such as leather gloves, heavy shirt, cuffless trousers, high
shoes, and a cap.
D Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.
D After completion of work, inspect area to ensure it is free of sparks,
glowing embers, and flames.
D Use only correct fuses or circuit breakers. Do not oversize or bypass them.
D Follow requirements in OSHA 1910.252 (a) (2) (iv) and NFPA 51B
for hot work and have a fire watcher and extinguisher nearby.
D Read and understand the Safety Data Sheets (SDSs) and the
manufacturer’s instructions for adhesives, coatings, cleaners,
consumables, coolants, degreasers, fluxes, and metals.
FLYING METAL or DIRT can injure eyes.
D Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool,
they can throw off slag.
D Wear approved safety glasses with side
shields even under your welding helmet.
BUILDUP OF GAS can injure or kill.
D Shut off compressed gas supply when not in use.
D Always ventilate confined spaces or use
approved air-supplied respirator.
ELECTRIC AND MAGNETIC FIELDS (EMF)
can affect Implanted Medical Devices.
D Wearers of Pacemakers and other Implanted
Medical Devices should keep away.
D Implanted Medical Device wearers should consult their doctor
and the device manufacturer before going near arc welding, spot
welding, gouging, plasma arc cutting, or induction heating
operations.
NOISE can damage hearing.
Noise from some processes or equipment can
damage hearing.
D Wear approved ear protection if noise level is high.
CYLINDERS can explode if damaged.
Compressed gas cylinders contain gas under high
pressure. If damaged, a cylinder can explode. Since
gas cylinders are normally part of the welding
process, be sure to treat them carefully.
D Protect compressed gas cylinders from excessive heat, mechanical shocks, physical damage, slag, open flames, sparks, and arcs.
D Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
D Keep cylinders away from any welding or other electrical circuits.
D Never drape a welding torch over a gas cylinder.
D Never allow a welding electrode to touch any cylinder.
D Never weld on a pressurized cylinder − explosion will result.
D Use only correct compressed gas cylinders, regulators, hoses,
and fittings designed for the specific application; maintain them
and associated parts in good condition.
D Turn face away from valve outlet when opening cylinder valve. Do
not stand in front of or behind the regulator when opening the valve.
D Keep protective cap in place over valve except when cylinder is in
use or connected for use.
D Use the right equipment, correct procedures, and sufficient number of persons to lift and move cylinders.
D Read and follow instructions on compressed gas cylinders,
associated equipment, and Compressed Gas Association (CGA)
publication P-1 listed in Safety Standards.
1-3. Additional Symbols For Installation, Operation, And Maintenance
FIRE OR EXPLOSION hazard.
D Do not install or place unit on, over, or near
combustible surfaces.
D Do not install unit near flammables.
D Do not overload building wiring − be sure power supply system is
properly sized, rated, and protected to handle this unit.
FALLING EQUIPMENT can injure.
D Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
D Use equipment of adequate capacity to lift and
support unit.
D If using lift forks to move unit, be sure forks are long enough to
extend beyond opposite side of unit.
D Keep equipment (cables and cords) away from moving vehicles
when working from an aerial location.
D Follow the guidelines in the Applications Manual for the Revised
NIOSH Lifting Equation (Publication No. 94−110) when manually lifting heavy parts or equipment.
OVERUSE can cause OVERHEATING
MOVING PARTS can injure.
D Keep away from moving parts such as fans.
D Keep all doors, panels, covers, and guards
closed and securely in place.
D Have only qualified persons remove doors, panels, covers, or
guards for maintenance and troubleshooting as necessary.
D Reinstall doors, panels, covers, or guards when maintenance is
finished and before reconnecting input power.
READ INSTRUCTIONS.
D Read and follow all labels and the Owner’s
Manual carefully before installing, operating, or
servicing unit. Read the safety information at
the beginning of the manual and in each
section.
D Use only genuine replacement parts from the manufacturer.
D Perform installation, maintenance, and service according to the
Owner’s Manuals, industry standards, and national, state, and
local codes.
D Allow cooling period; follow rated duty cycle.
D Reduce current or reduce duty cycle before
starting to weld again.
D Do not block or filter airflow to unit.
H.F. RADIATION can cause interference.
FLYING SPARKS can injure.
D Wear a face shield to protect eyes and face.
D Shape tungsten electrode only on grinder with
proper guards in a safe location wearing proper
face, hand, and body protection.
D
D Sparks can cause fires — keep flammables away.
D
STATIC (ESD) can damage PC boards.
D Put on grounded wrist strap BEFORE handling
boards or parts.
D Use proper static-proof bags and boxes to
store, move, or ship PC boards.
D
D
D High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communications equipment.
D Have only qualified persons familiar with
electronic equipment perform this installation.
The user is responsible for having a qualified electrician promptly correct any interference problem resulting from the installation.
If notified by the FCC about interference, stop using the
equipment at once.
Have the installation regularly checked and maintained.
Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.
MOVING PARTS can injure.
ARC WELDING can cause interference.
D Keep away from moving parts.
D Keep away from pinch points such as drive
rolls.
WELDING WIRE can injure.
D Do not press gun trigger until instructed to do
so.
D Do not point gun toward any part of the body,
other people, or any metal when threading
welding wire.
BATTERY EXPLOSION can injure.
D Do not use welder to charge batteries or jump
start vehicles unless it has a battery charging
feature designed for this purpose.
D
D
D
D
D Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.
D Be sure all equipment in the welding area is
electromagnetically compatible.
To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
Locate welding operation 100 meters from any sensitive electronic equipment.
Be sure this welding machine is installed and grounded
according to this manual.
If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables,
using line filters, or shielding the work area.
OM-257486 Page 3
1-4. California Proposition 65 Warnings
Welding or cutting equipment produces fumes or gases
which contain chemicals known to the State of California to
cause birth defects and, in some cases, cancer. (California
Health & Safety Code Section 25249.5 et seq.)
This product contains chemicals, including lead, known to
the state of California to cause cancer, birth defects, or other
reproductive harm. Wash hands after use.
1-5. Principal Safety Standards
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
is available as a free download from the American Welding Society at
http://www.aws.org or purchased from Global Engineering Documents
(phone: 1-877-413-5184, website: www.global.ihs.com).
Safe Practices for the Preparation of Containers and Piping for Welding
and Cutting, American Welding Society Standard AWS F4.1, from Global Engineering Documents (phone: 1-877-413-5184, website:
www.global.ihs.com).
Safe Practices for Welding and Cutting Containers that have Held Combustibles, American Welding Society Standard AWS A6.0, from Global
Engineering Documents (phone: 1-877-413-5184,
website: www.global.ihs.com).
National Electrical Code, NFPA Standard 70, from National Fire Protection Association, Quincy, MA 02269 (phone: 1-800-344-3555, website:
www.nfpa.org and www. sparky.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 14501 George Carter Way, Suite
103, Chantilly, VA 20151 (phone: 703-788-2700, website:www.cganet.com).
Safety in Welding, Cutting, and Allied Processes, CSA Standard
W117.2, from Canadian Standards Association, Standards Sales, 5060
Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5NS
(phone: 800-463-6727, website: www.csagroup.org).
Safe Practice For Occupational And Educational Eye And Face Protection, ANSI Standard Z87.1, from American National Standards Institute,
25 West 43rd Street, New York, NY 10036 (phone: 212-642-4900, website: www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, from National Fire Protection Association,
Quincy, MA 02269 (phone: 1-800-344-3555, website: www.nfpa.org).
OSHA, Occupational Safety and Health Standards for General Industry, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,
and Part 1926, Subpart J, from U.S. Government Printing Office, Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954
(phone: 1-866-512-1800) (there are 10 OSHA Regional Offices—
phone for Region 5, Chicago, is 312-353-2220, website:
www.osha.gov).
Applications Manual for the Revised NIOSH Lifting Equation, The National Institute for Occupational Safety and Health (NIOSH), 1600
Clifton Rd, Atlanta, GA 30329-4027 (phone: 1-800-232-4636, website:
www.cdc.gov/NIOSH).
1-6. EMF Information
Electric current flowing through any conductor causes localized electric
and magnetic fields (EMF). The current from arc welding (and allied processes including spot welding, gouging, plasma arc cutting, and
induction heating operations) creates an EMF field around the welding
circuit. EMF fields can interfere with some medical implants, e.g. pacemakers. Protective measures for persons wearing medical implants
have to be taken. For example, restrict access for passers−by or conduct individual risk assessment for welders. All welders should use the
following procedures in order to minimize exposure to EMF fields from
the welding circuit:
1. Keep cables close together by twisting or taping them, or using a
cable cover.
2. Do not place your body between welding cables. Arrange cables
to one side and away from the operator.
3. Do not coil or drape cables around your body.
OM- 257486 Page 4
4. Keep head and trunk as far away from the equipment in the
welding circuit as possible.
5. Connect work clamp to workpiece as close to the weld as
possible.
6. Do not work next to, sit or lean on the welding power source.
7. Do not weld whilst carrying the welding power source or wire
feeder.
About Implanted Medical Devices:
Implanted Medical Device wearers should consult their doctor and the
device manufacturer before performing or going near arc welding, spot
welding, gouging, plasma arc cutting, or induction heating operations.
If cleared by your doctor, then following the above procedures is recommended.
SECTION 2 − DEFINITIONS
2-1. Additional Safety Symbols And Definitions
Warning! Watch Out! There are possible hazards as shown by the symbols.
Safe1 2012−05
Wear dry insulating gloves. Do not touch electrode with bare hand. Do not wear wet or damaged gloves.
Safe2 2012−05
Protect yourself from electric shock by insulating yourself from work and ground.
Safe3 2012−05
Disconnect input plug or power before working on machine.
Safe5 2012−05
Keep your head out of the fumes.
Safe6 2012−05
Use forced ventilation or local exhaust to remove the fumes.
Safe8 2012−05
Use ventilating fan to remove fumes.
Safe10 2012−05
Keep flammables away from welding. Do not weld near flammables.
Safe12 2012−05
Welding sparks can cause fires. Have a fire extinguisher nearby, and have a watchperson ready to use it.
Safe14 2012−05
Do not remove or paint over (cover) the label.
Safe20 2012−05
OM-257486 Page 5
When power is applied failed parts can explode or cause other parts to explode.
Safe26 2012−05
Always wear long sleeves and button your collar when servicing unit.
Safe28 2012−05
After taking proper precautions as shown, connect power to unit.
Safe29 2012−05
Do not use one handle to lift or support unit.
Safe31 2012−05
Do not weld on drums or any closed containers.
Safe16 2012−05
Do not discard product (where applicable) with general waste.
Reuse or recycle Waste Electrical and Electronic Equipment (WEEE) by disposing at a designated collection
facility.
Contact your local recycling office or your local distributor for further information.
Safe37 2012−05
Disconnect input plug or power before working on machine.
Safe30 2012−05
Wear hat and safety glasses. Use ear protection and button shirt
collar. Use welding helmet with correct shade of filter. Wear complete
body protection.
Safe38 2012−05
Become trained and read the instructions before working on the
machine or welding.
Safe40 2012−05
= < 60°
Always lift and support unit using both handles. Keep angle of lifting
device less than 60 degrees.
Use a proper cart to move unit.
Safe44 2012−05
V
V
>60s
OM-257486 Page 6
V
Hazardous voltage remains on input capacitors after power is turned
off. Do not touch fully charged capacitors. Always wait 60 seconds
after power is turned off before working on unit, OR check input capacitor voltage, and be sure it is near 0 before touching any parts.
Safe42 2012−05
2-2. Miscellaneous Symbols And Definitions
A
Protective Earth
(Ground)
Amperage
Output
Line Connection
Off
Three Phase
Static Frequency
ConverterTransformerRectifier
Direct Current
(DC)
Constant Current
Arc Force
U0
Hz
Rated No Load
Voltage (Average)
Hertz
Pulsed
I1max
U2
I2
X
%
Circuit Breaker
Gas Tungsten Arc
Welding
Positive
Percent
Constant Voltage
Three Phase
Shielded Metal
Arc Welding
(SMAW)
Panel
Lift-Arc Operation
(GTAW)
Remote
U1
IP
Scratch Start TIG
Inductance
Primary Voltage
Degree Of
Protection
Lift-Arc Trigger
Hold Operation
(GTAW)
Negative
V
Rated Welding
Current
Single Phase
Duty Cycle
Rated Maximum
Supply Current
Alternating
Current (AC)
Conventional
Load Voltage
I1eff
Maximum Effective Supply Current
Voltage
Foot Control
Voltage Sensing
Feeder
On
Voltage Input
Gas Metal Arc
Welding (GMAW)
Increase
OM-257486 Page 7
SECTION 3 − SPECIFICATIONS
3-1. Serial Number And Rating Label Location
The serial number and rating information for this product is located on the rear panel. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on back cover of this manual.
3-2. Unit Specifications
. Do not use information in unit specifications table to determine electrical service requirements. See Sections 4-7 and 4-8 for information on connecting input power.
Rated
Output
Input
Power
3-Phase
Voltage
Range in
CV Mode
350 A at 34
VDC, 60%
Duty Cycle
Amperage
Range in
CC Mode
10−38 V
5−425 A
Max.
OpenCircuit
Voltage
RMS Amps Input at Rated Load Output, 60 Hz
3-Phase at NEMA Load Voltages and Class I
Rating
230 V
380 V
400 V
460 V
36.1
22.3
20.6
17.8
75 VDC
KVA
KW
14.2
13.6
*See Section 3-5 for Duty Cycle Rating.
3-3. Dimensions And Weight
Hole Layout Dimensions
A
A
E
(298 mm) 11-3/4 in.
B
(42 mm) 1-11/16 in.
C
(400 mm) 15-3/4 in.
D
(485 mm) 19-3/32 in.
E
(221 mm) 8-11/16 in.
F
(39 mm) 1-17/32 in.
G
1/4-20 UNC -2B thread
F
G
(610 mm)
24 in.
(432 mm)
17 in.
D
C
(318 mm)
12-1/2 in.
Weight
B
(36.3 kg) 80 lb
804 801-A
3-4. Environmental Specifications
A. IP Rating
IP Rating
Operating Temperature Range
Storage Temperature Range
14 to 104 °F (−10 to 40°C)
−4 to 131 °F (−20 to 55°C)
IP23
This equipment is designed for outdoor use. It
may be stored, but is not intended to be used
for welding outside during precipitation unless
sheltered.
OM-257486 Page 8
IP23 2014−06
B. Information On Electromagnetic Fields (EMF)
!
This equipment shall not be used by the general public as the EMF limits for the general public might be exceeded during welding.
This equipment is built in accordance with EN 60974−1 and is intended to be used only in an occupational environment (where the general public
access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person.
Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding
circuit may not be a major contributor to the EMF. See the Owner’s Manuals for all components of the welding circuit for additional EMF exposure
information.
S
S
The EMF assessment on this equipment was conducted at 0.5 meter.
At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values.
ce-emf 1 2010-10
C. Information On Electromagnetic Compatibility (EMC)
!
This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low−
voltage supply system. There can be potential difficulties in ensuring electromagnetic compatibility in those locations, due to conducted as well as radiated disturbances.
This equipment complies with IEC61000-3-11 and IEC 61000−3−12 and can be connected to public low-voltage systems provided that the public
low-voltage system impedance Zmax at the point of common coupling is less than 77.84 mW (or the short−circuit power Ssc is greater than
2,055,437.437 VA). It is the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator
if necessary, that the system impedance complies with the impedance restrictions.
ce-emc 1 2014-07
Notes
OM-257486 Page 9
3-5. Duty Cycle And Overheating
Duty Cycle is percentage of 10 minutes that unit can weld at rated load
without overheating.
If unit overheats, output stops, a
Help message is displayed and
cooling fan runs. Wait fifteen minutes for unit to cool. Reduce amperage or voltage, or duty cycle before
welding.
NOTICE − Exceeding duty cycle
can damage unit and void warranty.
60% Duty Cycle
6 Minutes Welding
Overheating
4 Minutes Resting
A or V
0
15
Minutes
OR
Reduce Duty Cycle
Ref. 219 523-A
Notes
OM-257486 Page 10
3-6. Volt-Ampere Curves
Volt-ampere curves show minimum
and maximum voltage and amperage output capabilities of welding
power source. Curves of other settings fall between curves shown.
A. CC Mode
100
90
80
VOLTS
70
60
50
SMAW
MAX
40
30
GTAW
MN
20
GTAW
MAX
SMAW
80A
0%
25%
ARC
CONTROL
50%
10
75%
100%
0
0
100
200
300
400
500
400
5 00
AMPERAGE
B. CV Mode
100
90
80
VOLTS
70
60
50
MAX
40
30
20
MIN
10
0
0
100
200
300
AMPERAGE
217 836-A / 217 837-B
OM-257486 Page 11
SECTION 4 − INSTALLATION
4-1. Selecting A Location
Movement
!
2
Do not move or operate unit
where it could tip.
2
OR
3
1
Location And Airflow
4
18 in.
(460 mm)
!
Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
1
Lifting Forks
Extend forks beyond opposite side
of unit.
2
Lifting Handles
Use handles to lift unit.
3
Hand Cart
Use cart or similar device to move
unit.
4
18 in.
(460 mm)
Line Disconnect Device
Locate unit near correct input
power supply.
loc_med 2015-04
Notes
OM-257486 Page 12
4-2. Selecting Cable Sizes*
NOTICE − The Total Cable Length in Weld Circuit (see table below) is the combined length of both weld cables. For example, if the power source
is 30 m (100 ft) from the workpiece, the total cable length in the weld circuit is 60 m (2 cables x 30 m). Use the 60 m (200 ft) column to determine
cable size.
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit
Not Exceeding***
30 m (100 ft) or Less
Welding
Amperes
10 − 60%
Duty
Cycle
mm2 (AWG)
45 m (150
ft)
60 m (200 ft)
60 − 100%
Duty Cycle
70 m (250
ft)
90 m (300
ft)
105 m (350
ft)
120 m (400
ft)
10 − 100% Duty Cycle
mm2 (AWG)
mm2 (AWG)
100
20 (4)
20 (4)
20 (4)
30 (3)
35 (2)
50 (1)
60 (1/0)
60 (1/0)
150
30 (3)
30 (3)
35 (2)
50 (1)
60 (1/0)
70 (2/0)
95 (3/0)
95 (3/0)
200
30 (3)
35 (2)
50 (1)
60 (1/0)
70 (2/0)
95 (3/0)
120 (4/0)
120 (4/0)
250
35 (2)
50 (1)
60 (1/0)
70 (2/0)
95 (3/0)
120 (4/0)
2x70 (2x2/0)
2x70 (2x2/0)
300
50 (1)
60 (1/0)
70 (2/0)
95 (3/0)
120 (4/0)
2x70 (2x2/0)
2x95 (2x3/0)
2x95 (2x3/0)
350
60 (1/0)
70 (2/0)
95 (3/0)
120 (4/0)
2x70 (2x2/0)
2x95 (2x3/0)
2x95 (2x3/0)
2x120 (2x4/0)
400
60 (1/0)
70 (2/0)
95 (3/0)
120 (4/0)
2x70 (2x2/0)
2x95 (2x3/0)
2x120 (2x4/0)
2x120 (2x4/0)
500
70 (2/0)
95 (3/0)
120 (4/0)
2x70 (2x2/0)
2x95 (2x3/0)
2x120 (2x4/0)
3x95 (3x3/0)
3x95 (3x3/0)
600
95 (3/0)
120 (4/0)
2x70 (2x2/0)
2x95 (2x3/0)
2x120 (2x4/0)
3x95 (3x3/0)
3x120 (3x4/0)
3x120 (3x4/0)
* This
chart is a general guideline and may not suit all applications. If cable overheats, use next size larger cable.
**Weld cable size is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
***For distances longer than those shown in this guide, call a factory applications representative.
Milan Ref. S-0007-L 2015−02
4-3. Weld Output Terminals
!
Turn off power before connecting
to weld output terminals.
!
Do not use worn, damaged, undersized, or repaired cables.
1
Positive (+) Weld Output Terminal
2
Negative (−) Weld Output Terminal
1
2
Ref. 803 692-B / output term1 2015−02
OM-257486 Page 13
4-4. Remote 14 Receptacle Information
A
B
K
J
Socket*
Socket Information
A
24 volts AC. Protected by supplementary protector CB2.
B
Contact closure to A completes 24 volts AC
contactor control circuit.
C
Output to remote control; 0 to +10 volts DC, +10
volts DC in MIG mode.
D
Remote control circuit common.
E
0 to +10 volts DC input command signal from
remote control.
M
CC/CV select
F
Current feedback; +1 volt DC per 100 weld amperes.
H
Voltage feedback; +1 volt DC per 10 weld volts.
G
Circuit common for 24 and 115 volts AC circuits.
K
Chassis common.
24 VOLTS AC
I
H
C L N
D M
G
E F
REMOTE
OUTPUT
CONTROL
A/V
AMPERAGE
VOLTAGE
GND
*The remaining sockets are not used.
4-5. Supplementary Protectors
1
Supplementary Protector CB2
CB2 protects 24 volts AC portion of
Remote 14 receptacle from
overload.
Press button to reset protector.
1
956142947_2-B
OM-257486 Page 14
4-6. Optional Gas Valve Operation And Shielding Gas Connection
Obtain gas cylinder and chain to
running gear, wall, or other stationary support so cylinder cannot fall
and break off valve.
4
1
Cylinder
2
Regulator/Flowmeter
Install so face is vertical.
3
GAS IN
Gas Hose Connection
Fitting has 5/8-18 right-hand
threads. Obtain and install gas
hose.
2
4
Gas In Fitting
5
Gas Out Fitting
The Gas In and Gas Out fittings
have 5/8-18 right-hand threads.
Obtain proper size, type, and length
hose and make connections as follows:
Connect hose from shielding gas
supply regulator/flowmeter to Gas
In fitting.
Connect hose coupler to torch.
Connect one end of gas hose to
hose coupler. Connect remaining
end of gas hose to Gas Out fitting.
Operation
3
1
The gas solenoid controls gas flow
during the TIG process as follows:
Remote TIG
Gas flow starts with remote contactor on.
Gas flow stops at end of post−flow
if current was detected, or with remote contactor off if no current was
detected.
Lift−Arc Trigger Hold TIG
Gas flow starts when output switch
is depressed.
Gas flow stops at end of post−flow.
Scratch Start TIG
5
GAS OUT
Gas flow starts when current is detected.
Gas flow stops at end of post−flow.
Post−flow time is factory set to 5
seconds per 100 amps of weld current. The minimum post−flow time
is 5 seconds. The maximum post−
flow is 20 seconds (post flow settings are not adjustable by the end
user).
956142947_3-B / Ref. 803 879-B
OM-257486 Page 15
4-7. Electrical Service Guide
Elec Serv 2014−01
NOTICE − INCORRECT INPUT POWER can damage this welding power source. Phase to ground voltage shall not exceed +10% of rated input
voltage.
NOTICE − Actual input voltage should not be 10% less than minimum and/or 10% more than maximum input voltages listed in table. If actual input
voltage is outside this range, output may not be be available.
Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommendations are for a dedicated circuit sized for the rated output and duty cycle of the welding power source.
In dedicated circuit installations, the National Electrical Code (NEC) allows the receptacle or conductor rating to be less than the rating
of the circuit protection device. All components of the circuit must be physically compatible. See NEC articles 210.21, 630.11, and
630.12.
60 Hz Three Phase
Input Voltage (V)
230
380
400
460
Input Amperes (A) At Rated Output
36.1
22.3
20.6
17.8
40
25
25
20
50
30
30
25
10
12
12
14
96
(29)
158
(48)
175
(53)
150
(46)
10
12
12
14
Max Recommended Standard Fuse Rating In
Amperes 1
Time-Delay 2
Normal Operating
3
Min Input Conductor Size In AWG
4
Max Recommended Input Conductor Length In
Feet (Meters)
Min Grounding Conductor Size In AWG 4
Reference: 2014 National Electrical Code (NEC) (including article 630)
1 If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse.
2 “Time-Delay” fuses are UL class “RK5” . See UL 248.
3 “Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amps), and UL class “H” ( 65 amps and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.15(B)(16). If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable
requirements.
Notes
OM-257486 Page 16
Notes
OM-257486 Page 17
4-8. Connecting 3-Phase Input Power
3
= GND/PE Earth Ground
4
7
2
L1
3
L2
5
L3
6
1
Tools Needed:
input2 2012−05 − Ref. 803 766-C / 803 879-B
OM-257486 Page 18
4-8. Connecting 3-Phase Input Power (Continued)
!
Installation must meet all National and
Local Codes − have only qualified persons make this installation.
!
Disconnect and lockout/tagout input
power before connecting input conductors from unit. Follow established
procedures regarding the installation
and removal of lockout/tagout
devices.
!
Always connect green or green/yellow
conductor to supply grounding terminal first, and never to a line terminal.
. The Auto-Line circuitry in this unit auto-
matically adapts the power source to the
primary voltage being applied. Check input voltage available at site. This unit can
be connected to any input power between
208 and 575 VAC without removing cover
to relink the power source.
See rating label on unit and check input voltage available at site.
For Three-Phase Operation
1
2
3
4
Input Power Cord.
Disconnect Device (switch shown in the
OFF position)
Green Or Green/Yellow Grounding
Conductor
Disconnect Device Grounding Terminal
5
6
Input Conductors (L1, L2 And L3)
Disconnect Device Line Terminals
Connect green or green/yellow grounding
conductor to disconnect device grounding terminal first.
Connect input conductors L1, L2, and L3 to
disconnect device line terminals.
7
Over-Current Protection
Select type and size of over-current protection using Section 4-7 (fused disconnect
switch shown).
Close and secure door on disconnect device.
Follow established lockout/tagout procedures
to put unit in service.
input2 2012−05
Notes
Work like a Pro!
Pros weld and cut
safely. Read the
safety rules at
the beginning
of this manual.
OM-257486 Page 19
SECTION 5 − OPERATION
5-1. Front Panel Controls
1
Power Switch
6
. The
fan motor is thermostatically
controlled and only runs when cooling is
needed.
2 Voltmeter
3 Ammeter
4 V/A (Voltage/Amperage) Adjustment
Control
5 Mode Switch
The Mode switch setting determines both the
process and output On/Off control (see
Section 5-3).
For Air Carbon Arc (CAC-A) cutting and
gouging, place switch in Stick position. For
best results, place Arc Control in the
maximum position.
Remote 14 Receptacle
voltage is the same as normal welding
amperage.
For remote control, make connections to
Remote 14 receptacle. In TIG modes and the
REMOTE STICK mode, remote control is a
percent of V/A Adjust control setting (value
selected on V/A Adjust is maximum available
on remote). In ELECTRODE HOT STICK
mode the remote control is not used. In the
MIG mode, remote control provides full range
of unit output regardless of V/A Adjust control
setting.
7
Arc Control
Control adjusts Dig when Stick or CC mode is
selected on mode switch. When set towards
minimum, short-circuit amperage at low arc
2
3
When set towards maximum, short-circuit
amperage is increased at low arc voltage to
assist with arc starts as well as reduce
sticking while welding.
Select setting best suited for application.
Control adjusts inductance when MIG or
V-Sense Feeder position is selected on the
mode switch. Inductance determines the
“wetness” of the weld puddle. When set
towards maximum, “wetness” (puddle fluidity)
increases.
When Pulsed MIG or one of the TIG modes is
selected, this control is not functional.
4
ELECTRODE HOT
6
5
7
1
Ref. 803 692-B / Ref. 219 341-A
OM-257486 Page 20
5-2. Meter Functions
. The meters display the actual weld output values for approximately three seconds after the arc is broken.
Mode
Meter Reading At Idle
V
Scratch
Start TIG
Meter Reading While Welding
A
71.7
85
Actual Volts
Actual Amps
V
A
V
A
Blank
Preset Amps
Actual Volts
Actual Amps
V
A
V
A
Blank
Preset Amps
Actual Volts
Actual Amps
V
A
V
A
24.5
250
85
85
24.5
10.3
85
85
Blank
Actual Volts
Actual Amps
V
A
V
A
PPP
PPP
24.5
250
Pulse Display
Pulse Display
Actual Volts
Actual Amps
V
A
V
A
85
24.5
85
Blank
Preset Amps
Actual Volts
Actual Amps
V
A
V
A
71.7
V-Sense
Feeder
10.3
Preset Volts
CC
Stick
85
Preset Amps
TIG
Pulsed
MIG
10.3
A
Actual Volts (OCV)
Lift-Arc Trigger Hold TIG
MIG
V
85
24.5
85
Actual Volts (OCV)
Preset Amps
Actual Volts
Actual Amps
V
A
V
A
24.5
250
Actual Volts
Actual Amps
71.7
Flashes OCV And Preset
Blank
5-3. Mode Switch Settings
. The Stick and CC modes provide the Adaptive Hot Start™ feature, which automatically increases the output amperage at the start of a weld should
the start require it. This eliminates electrode sticking at arc start.
Mode Switch Setting
Process
Output On/Off Control
Scratch Start TIG
GTAW
Electrode Hot
Lift-Arc Trigger Hold TIG
GTAW − See Section 5-4
At Remote 14
TIG
GTAW With HF Unit, Pulsing Device, Or Remote Control
At Remote 14
MIG
GMAW
At Remote 14
Pulsed MIG
GMAW-P (Requires an external pulsing device.)
At Remote 14
CC
Stick (SMAW) With Remote On/Off
At Remote 14
Stick
SMAW
Electrode Hot
V-Sense Feeder
MIG (GMAW) With Voltage Sensing Wire Feeder
Electrode Hot
OM-257486 Page 21
5-4. Lift-Arc Trigger Hold TIG
1
TIG Electrode
2
Workpiece
. Procedure requires:
control
Start sequence:
1
•
2
•
•
“Touch”
•
Touch tungsten electrode to
workpiece at weld start point.
Momentarily depress output
switch.
Slowly lift electrode. An arc will
form when electrode is lifted.
To stop welding, momentarily
depress output switch and output will shut off.
Note: If output switch is momentarily depressed and tungsten is
not touching workpiece:
1−2
Seconds
Do not touch tungsten to work.
Output will shut off in 3 seconds.
Start sequence over.
Do NOT Strike Like A Match!
Ref. S-156 279
5-5.
Stick Start Procedure
With Stick selected, start arc as follows:
1
2
3
Electrode
Workpiece
Arc
Drag electrode across workpiece
like striking a match; lift electrode
slightly after touching work. If arc
goes out electrode was lifted to high.
If electrode sticks to workpiece, use
a quick twist to free it.
1
Low OCV Stick
2
3
OM-257486 Page 22
The unit can be optionally configured for low open circuit voltage
(OCV) operation. When the unit is
configured for low OCV operation
only a low sensing voltage (approximately 15 VDC) is present between
the electrode and the workpiece
prior to the electrode touching the
workpiece. Consult a Factory
Authorized Service Agent for information regarding how to configure
the unit for low OCV stick welding
operation.
SECTION 6 − MAINTENANCE & TROUBLESHOOTING
6-1. Routine Maintenance
!
Disconnect power
before maintaining.
. Maintain more often
during severe conditions.
3 Months
Repair Or
Replace
Cracked
Cables
Replace
Damaged Or
Unreadable
Labels
Replace Cracked
Torch Body
Repair Or Replace
Cracked Cables
And Cords
Clean
And
Tighten Weld
Connections
6 Months
Blow Out Inside
6-2. Blowing Out Inside Of Unit
!
Do not remove case when
blowing out inside of unit.
To blow out unit, direct airflow
through front and back louvers as
shown.
Ref. 803 879-B / 956142947_3-B
OM-257486 Page 23
6-3. Voltmeter/Ammeter Help Displays
V
A
1
HE.L
P−1
V
A
2
HE.L
P−2
V
A
P−3
. All directions are in reference to the front
of the unit. All circuitry referred to is located inside the unit.
Help 1 Display
Indicates a malfunction in the primary power
circuit. If this display is shown, contact a Factory Authorized Service Agent.
Help 2 Display
Indicates a malfunction in the thermal protection circuitry. If this display is shown, contact
a Factory Authorized Service Agent.
3
HE.L
P−5
V
A
HE.L
P−6
V
A
HE.L
P−8
6
HE.L
2
A
5
3
1
V
4
Help 3 Display
Indicates the left side of the unit has overheated. The unit has shut down to allow the
fan to cool it (see Section 3-5). Operation will
continue when the unit has cooled.
4
Help 5 Display
Indicates the right side of the unit has overheated. The unit has shut down to allow the
fan to cool it (see Section 3-5). Operation will
continue when the unit has cooled.
5
Help 6 Display
Indicates operation at maximum input current. The unit has a maximum allowable input
current limit. As the line voltage decreases,
the required input current increases. If the line
voltage is too low, the output power is limited
by the input current. When this limit is
reached, the unit automatically reduces output power to continue operation. If this display
is shown, have a qualified electrician check
the input voltage.
6
Help 8 Display
Indicates a malfunction in the secondary
power circuit of the unit. If this display is
shown, contact a Factory Authorized Service
Agent.
6-4. Troubleshooting
Trouble
No weld output; unit completely inoperative.
Remedy
Place line disconnect switch in On position (see Section 4-8).
Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section 4-8).
Check for proper input power connections (see Section 4-8).
No weld output; meter display On.
Input voltage outside acceptable range of variation (see Sections 4-7, 4-8).
Check, repair, or replace remote control.
Unit overheated. Allow unit to cool with fan On (see Section 3-5).
Erratic or improper weld output.
Use proper size and type of weld cable (see Section 4-2).
Clean and tighten all weld connections.
Check for correct polarity.
No 24 volts AC output at Remote 14
receptacle.
OM-257486 Page 24
Reset supplementary protector CB2 (see Section 4-5).
Notes
OM-257486 Page 25
SECTION 7 − ELECTRICAL DIAGRAM
Figure 7-1. Circuit Diagram
OM-257486 Page 26
956142946-C
OM-257486 Page 27
OM-257486 Page 28
73
4
1
3
5
69
Figure 8.1. Parts Assembly
72
67
71
2
6
70
66
9
65
64
10
76
68
62
63
74
13
8
11
12
62
58
75
57
77
14
61
83
18
15
16
54
51
22
56
59
21
53
60
17
52
19
20
23
50
24
55
MOD 1
48
49
28
25
46
79
40
37
42
43
80
44
41
39
MOD 2
38
26
30
32
49
45
78
31
17
47
81
29
82
34
35
36
SECTION 8 − PARTS LIST
956142947_1-B
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 8.1. Parts Assembly
. . . 1 . . . . . . . . . . . . . . . 216034 . . Wrapper (Includes Insulators and Safety Labels) . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . 175256 . . Insulator, Side Rh (Not Shown) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . 178551 . . Insulator, Side (Not Shown) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 2 . . . . . . . . . . . . . . . 179310 . . Label, General Precautionary Wordless, Intl, Small . . . . . . . . . . . . . . . . . 2
. . . 3 . . . . . . . . . . . . . . . 179309 . . Label, Caution Falling Equipment Can Injure−wordles . . . . . . . . . . . . . . . 2
. . . 4 . . . . . . . . . . . . . . . 208015 . . Handle, Rubberized Carrying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 5 . . . . . . . . . . . . . . . 135483 . . Label, Important Remove These Two Handle Screws . . . . . . . . . . . . . . . 2
. . . 6 . . . . R3/C4 . . . . 233052 . . Resistor/Capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 7 . . . . . . . . . . . . . . . Deleted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 8 . . . . . SR1 . . . . . 201530 . . Kit, Diode Fast Recovery Bridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 9 . . . . . . . . . . . . . . . 199840 . . Bus Bar, Diode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 10 . . . . . . . . . . . . . . . 196355 . . Insulator, Screw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . 11 . . . . D1,D2 . . . . 201531 . . Kit, Diode Power Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 12 . . . . . RT1 . . . . . 219343 . . Thermistor, NTC 30K Ohm @ 25 Deg C 18in Lead . . . . . . . . . . . . . . . . . 1
. . . 13 . . . . . CR1 . . . . . 198549 . . Relay, Encl 24VDC Spst 35A/300VAC 4Pin Flange Mtg . . . . . . . . . . . . . 1
. . . 14 . . . . . . . . . . . . . . . 227927 . . Label, Warning Electric Shock/Exploding Parts−wdles . . . . . . . . . . . . . . . 1
. . . 15 . . . . . . . . . . . . . . . 010546 . . Bushing, Snap-In Nyl .375 Id X .500 Mtg Hole . . . . . . . . . . . . . . . . . . . . . 1
. . . 16 . . . . . . L4 . . . . . . 218020 . . Inductor, Boost . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 17 . . . . . . . . . . . . . . . 179276 . . Bushing, Snap-In Nyl 1.000 Id X 1.375 Mtg Hole Cent . . . . . . . . . . . . . . 3
. . . 18 . . . . . . . . . . . . . . . 170647 . . Bushing, Snap-In Nyl 1.312 Id X 1.500 Mtg Hole . . . . . . . . . . . . . . . . . . . 1
. . . 19 . . . . . . L3 . . . . . . 212150 . . Inductor, Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 20 . . . . . . T1 . . . . . . 212132 . . XFMR, HF Litz/Litz W/Boost . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 21 . . . . . . . . . . . . . . . 225097 . . Heat Sink, Lh Rect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 22 . . . . . . L1 . . . . . . 212091 . . Inductor, Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 23 . . . . . . . . . . . . . . . 083147 . . Grommet, Scr No 8/10 Panel Hole .312 Sq .500 High . . . . . . . . . . . . . . . 4
. . . 24 . . . . . PC1 . . . . . 274574 . . Circuit Card Assy, Control W/Prgm 350 Prod Aux Pwr . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . . 216113 . . Stand-Off Support, PC Card .187 Dia W/P&l .375 . . . . . . . . . . . . . . . . . . 2
. . . . . . . . . . PLG1 . . . . . 115091 . . Housing Plug+Pins (Service Kit) RC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . PLG2 . . . . 201665 . . Housing Plug+Pins (Service Kit) RC2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . PLG3 . . . . 131056 . . Housing Plug+Pins (Service Kit) RC3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . PLG5 . . . . 131204 . . Housing Plug+Pins (Service Kit) RC5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . PLG7 . . . . 131054 . . Housing Plug+Pins (Service Kit) RC7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . PLG8 . . . . 131054 . . Housing Plug+Pins (Service Kit) RC8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . PLG9 . . . . . 115093 . . Housing Plug+Pins (Service Kit) RC9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . PLG10 . . . . . 115094 . . Housing Plug+Pins (Service Kit) RC10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . PLG11 . . . . . 115094 . . Housing Plug+Pins (Service Kit) RC11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . PLG12 . . . . . 115092 . . Housing Plug+Pins (Service Kit) RC12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 25 . . . . . . . . . . . . . . . 212072 . . Bracket, Mtg Capacitor/Pc Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 26 . . . C12, 13 . . . 245614 . . Capacitor, Elctlt 1800 Uf 500 VDC Can 2.52 Dia . . . . . . . . . . . . . . . . . . . 2
. . . 27 . . . . . RC2 . . . . . 604176 . . Deleted
. . . 28 . . . . . CB2 . . . . . 083432 . . Circuit Breaker, Man Reset 1P 10A 250VAC Frict . . . . . . . . . . . . . . . . . . 1
. . . 29 . . . . . . . . . . . . 656043033 . . Plug, Snap-In D9.5 Mtg Hole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 30 . . . . . . . . . . . +156118085 . . Panel, Rear CE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 31 . . . . . . . . . . . . . . . 219335 . . Label, Warning Electric Shock Can Kill CE Wordless . . . . . . . . . . . . . . . . 1
. . . 32 . . . . . . . . . . . . . . . . . . . . . . . . . . Nameplate, Rear Aux/Gas/CE (Order by Model and Serial Number) . . 1
. . . 33 . . . . . . . . . . . . . . . 217297 . . Deleted
. . . 34 . . . . . . . . . . . . . . . 212945 . . Label, Warning Incorrect Connections CE Wordless . . . . . . . . . . . . . . . . 1
. . . 35 . . . . . . . . . . . . . . . 215980 . . Bushing, Strain Relief .709/.984 Id X1.375 Mtg Hole . . . . . . . . . . . . . . . . 1
. . . 36 . . . . . . . . . . . . . . . 244628 . . Cable, Power 12Ft 8Ga 4C (Non−Stripped End) . . . . . . . . . . . . . . . . . . . . 1
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
BE SURE TO PROVIDE MODEL AND SERIAL NUMBER WHEN ORDERING REPLACEMENT PARTS.
OM-257486 Page 29
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 8.1. Parts Assembly (Continued)
. . . 37 . . . . . . . . . . . . . . . 234126 . . Nut, Conduit 1.000 Npt Knurled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 38 . . . . . . T2 . . . 028021467 . . XFMR, Control Toroidal 665 VAC Pri 340 Va 60 Hz . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 212947 . . . . Plate, Mtg Toroid XFMR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 39 . . . . . . L2 . . . . . . 218018 . . Inductor, Pre-Regulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 40 . . . . . . . . . . . . . . . 218566 . . Gasket, Inductor Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 41 . . . . . CT1 . . . . . 196231 . . XMFR, Current Sensing 200/1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 42 . . . . . C15 . . . . . 196143 . . Capacitor, Polyp Met Film 16. Uf 400 VAC 10% . . . . . . . . . . . . . . . . . . . .
. . . 43 . . . . . . . . . . . . . . . 219472 . . Bracket, Mtg Capacitor Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 44 . . . . . RT2 . . . . . 199798 . . Thermistor, NTC 30K Ohm @ 25 Deg C 18in Lead . . . . . . . . . . . . . . . . .
. . . 45 . . . . . PC2 . . . . . 224661 . . Circuit Card Assy, Power Interconnect (Includes) . . . . . . . . . . . . . . . . . . .
. . . 46 . . . . . . . . . . . . . . . 219335 . . . . Label, Warning Electric Shock Can Kill Ce Wordless . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 223343 . . . . Clip, Wire Stdf .40−.50 Bndl .156Hole .031−.078Thk . . . . . . . . . . . . . .
. . . . . . . . . . PLG13 . . . . 130203 . . Housing Plug+Pins (Service Kit) RC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG14 . . . . 201665 . . Housing Plug+Pins (Service Kit) RC2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG15 . . . . . 115092 . . Housing Plug+Pins (Service Kit) RC3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG20 . . . . . 115093 . . Housing Plug+Pins (Service Kit) RC6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 47 . . . . . . . . . . . . . . . 153403 . . Bushing, Snap-In Nyl .750 Id X 1.000 Mtg Hole Cent . . . . . . . . . . . . . . . .
. . . 48 . . . . . RM1 . . . . . 205751 . . Module, Power Resistor W/Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 49 . . . . . . . . . . . . . . . 261556 . . Kit, Input/Pre-Regulator And Inverter Module (Includes) . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MOD 1, SKiip 83 HEC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MOD 2, SKiip 83 EC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 50 . . . . . . . . . . . . . . . 212206 . . Windtunnel, Rh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 51 . . . . . . . . . . . . . . . 196330 . . Heat Sink, Power Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 52 . . . . . . . . . . . . . . +175132 . . Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 53 . . . . . . . . . . . . . . . 229325 . . Foot, Mtg Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 54 . . . . . . . . . . . . . . . 176736 . . Screw, Mtg Foot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 55 . . . . . . . . . . . . . . . 212073 . . Label, Warning Exploding Parts Can CE Wordless . . . . . . . . . . . . . . . . . .
. . . 56 . . . . . . . . . . . . . . . 212074 . . Bus Bar, Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 57 . . . . . HD1 . . . . . 182918 . . Transducer, Current 400A Module Supply V +/− 15V . . . . . . . . . . . . . . . .
. . . 58 . . . . . PC3 . . . . . 243654 . . Circuit Card Assy, Front Panel & Display W/Program . . . . . . . . . . . . . . .
. . . . . . . . . . PLG18 . . . . 131204 . . Housing Plug+Pins (Service Kit) RC2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . RC50 . . . . 210233 . . Rcpt, W/Pins (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . PLG21 . . . . 212088 . . Plug, W/Leads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . RC21 . . . . 167640 . . Housing Plug+Pins (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 59 . . . . . . S1 . . . . . 244920 . . Switch, Tgl 3Pst 40A 600VAC Scr Term Wide Tgl . . . . . . . . . . . . . . . . . .
. . . 60 . . . . . . . . . . . . . . . 176226 . . Insulator, Switch Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 61 . . . . . FM1 . . . . . 196313 . . Fan, Muffin 115V 50/60Hz 3000 RPM 6.378 Mtg Holes . . . . . . . . . . . . . .
. . . . . . . . . . PLG16 . . . . 131054 . . Housing Plug+Pins (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . RC16 . . . . 135635 . . Housing Plug+Pins (Service Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 62 . . . . . . . . . . . . . . . 208967 . . Rcpt Assy, Tw Lk Insul Fem (Dinse Type) 50/70 Series (Includes) . . . .
. . . . . . . . . . . . . . . . . . . . . 208968 . . . . Rcpt, Tw Lk Insul W/O-Ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 185712 . . . . Insulator, Bulkhead Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 185713 . . . . Insulator, Bulkhead Rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 185714 . . . . Washer, Tooth 22mmid X 31.5mmod 1.310-1mmt Intern . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 185717 . . . . Nut, M20-1.5 1.00Hex .19H Brs Locking . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 185718 . . . . O-Ring, 0.989 Id X 0.070 H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . 186228 . . . . O-Ring, 0.739 Id X 0.070 H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 63 . . . . . . . . . . . . . . . 212070 . . Panel, Front Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 64 . . . . C5,6,7 . . . . 233668 . . Capacitor Assy, W/Plug & Leads (Voltage Feedback) . . . . . . . . . . . . . . .
. . . 65 . . . . . . . . . . . . . . . . 216112 . . Fastener, Panel Receptacle Quick Access . . . . . . . . . . . . . . . . . . . . . . . .
. . . 66 . . . . . . . . . . . . . . . . . . . . . . . . . . Nameplate (Order by Model and Serial Number) . . . . . . . . . . . . . . . . . . .
. . . 67 . . . . . . . . . . . . . . . . . . . . . . . . . . Nameplate, Connection (Order by Model and Serial Number) . . . . . . . .
. . . 68 . . . . . . . . . . . . . . . . . . . . . . . . . . Nameplate, Power (Order by Model and Serial Number) . . . . . . . . . . . . .
. . . 69 . . . . . . . . . . . . . . . 174991 . . Knob, Pointer 1.250 Dia X .250 Id W/Spring Clip−.21 . . . . . . . . . . . . . . .
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
BE SURE TO PROVIDE MODEL AND SERIAL NUMBER WHEN ORDERING REPLACEMENT PARTS.
OM-257486 Page 30
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
3
1
1
1
1
1
1
1
4
4
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
2
1
1
1
2
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 8.1. Parts Assembly (Continued)
...
...
...
...
...
...
...
...
...
...
...
...
...
...
70
71
72
73
74
75
76
77
78
79
80
81
82
83
. . . . . . . . . . . . . . . 174992 . .
. . . . . . . . . . . . . . . 218041 . .
. . . . . . . . . . . . . . . 175138 . .
..........................
. . . . . . . . . . . . . . +212207 . .
. . . . . . . . . . . . . . . . 211503 . .
. . . . . C8 . . . . . 219191 . .
. . . . . . L6 . . . . . . 131447 . .
. . . . L5,L7 . . . . 199122 . .
. . . . . . . . . . . . . . . 083147 . .
. . . . . . . . . . . . . . . 219471 . .
. . . . . . . . . . . . . . . 219473 . .
. . . . . PC4 . . . . . 229989 . .
. . . . . . . . . . . . . . . 227746 . .
Knob, Pointer .840 Dia X .250 Id W/Spring Clip−.21 . . . . . . . . . . . . . . . .
Door, W/Quick Access Ball Fasteners . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Box, Louver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Label (Order by Model and Serial Number) . . . . . . . . . . . . . . . . . . . . . . . .
Windtunnel, Lh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Insulator, Heat Sink . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Capacitor, Polyp Film .001 Uf 2000V W/Terms . . . . . . . . . . . . . . . . . . . . .
Core, Toroidal 1.332 Id X 1.932 Od X .625 Thk . . . . . . . . . . . . . . . . . . . . .
Core, Toroidal .750 Id X 1.450 Od X .544 Thk . . . . . . . . . . . . . . . . . . . . . .
Grommet, Scr No 8/10 Panel Hole .312 Sq .500 High . . . . . . . . . . . . . . .
Bracket, Mtg Filter Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bracket, Mtg CE Filter Ground Plane . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Circuit Card Assy, Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gasket, Inductor Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
1
1
1
1
1
2
2
1
1
1
1
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
BE SURE TO PROVIDE MODEL AND SERIAL NUMBER WHEN ORDERING REPLACEMENT PARTS.
OM-257486 Page 31
Notes
Notes
Effective January 1, 2016
(Equipment with a serial number preface of MG or newer)
This limited warranty supersedes all previous Miller warranties and is exclusive with no other
guarantees or warranties expressed or implied.
LIMITED WARRANTY − Subject to the terms and conditions
below, ITW Welding Products Italy warrants to its original retail
purchaser that new Miller equipment sold after the effective date
of this limited warranty is free of defects in material and
workmanship at the time it is shipped by Miller. THIS
WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS.
Within the warranty periods listed below, Miller will repair or
replace any warranted parts or components that fail due to such
defects in material or workmanship. Miller must be notified in
writing within thirty (30) days of such defect or failure, at which
time Miller will provide instructions on the warranty claim
procedures to be followed. If notification is submitted as an
online warranty claim, the claim must include a detailed
description of the fault and the troubleshooting steps taken to
identify failed components and the cause of their failure.
Miller shall honor warranty claims on warranted equipment listed
below in the event of such a failure within the warranty time
periods. All warranty time periods start on the date the
equipment was delivered to the original retail purchaser or one
year after the equipment is shipped to a European distributor or
twelve months after the equipment is shipped to an International
distributor.
1.
5 Years Parts — 3 Years Labor
*
2.
3 Years — Parts and Labor
*
*
*
*
*
3.
Auto-Darkening Helmet Lenses (No Labor)
Migmatic 175
HF Units
1 Year — Parts and Labor Unless Specified
*
*
*
*
*
*
*
*
*
*
*
5.
Engine Driven Welding Generators
(NOTE: Engines are warranted separately by the
engine manufacturer.)
Inverter Power Sources (Unless Otherwise Stated)
Process Controllers
Semi-Automatic and Automatic Wire Feeders
Transformer/Rectifier Power Sources
2 Years — Parts
*
*
*
4.
Original main power rectifiers only to include SCRs,
diodes, and discrete rectifier modules with
exclusion of STR, Si, STi, STH and MPi series.
Automatic Motion Devices
Field Options
(NOTE: Field options are covered under True
Blue) for the remaining warranty period of the
product they are installed in, or for a minimum of
one year — whichever is greater.)
Induction Heating Power Sources, Coolers, and
Electronic Controls/Recorders
Motor-Driven Guns (w/exception of Spoolmate
Spoolguns)
Positioners and Controllers
Powered Air Purifying Respirator (PAPR) Blower
Unit (No Labor)
Racks
Running Gear and Trailers
Subarc Wire Drive Assemblies
Water Coolant Systems
Work Stations/Weld Tables (No Labor)
6 Months — Parts
*
Batteries
6.
90 Days — Parts
*
*
*
*
*
*
Accessory (Kits)
Canvas Covers
Induction Heating Coils and Blankets
MIG Guns
Remote Controls
Replacement Parts (No Labor)
*
*
Spoolmate Spoolguns
Cables and Non-Electronic Controls
Miller’s True Blue® Limited Warranty shall not apply to:
1.
Consumable components; such as contact tips,
cutting nozzles, contactors, brushes, switches, slip
rings, relays or parts that fail due to normal wear.
2.
Items furnished by Miller, but manufactured by others, such
as engines or trade accessories. These items are covered
by the manufacturer’s warranty, if any.
3.
Equipment that has been modified by any party other than
Miller, or equipment that has been improperly installed,
improperly operated or misused based upon industry
standards, or equipment which has not had reasonable and
necessary maintenance, or equipment which has been
used for operation outside of the specifications for the
equipment.
MILLER PRODUCTS ARE INTENDED FOR PURCHASE AND
USE BY COMMERCIAL/INDUSTRIAL USERS AND PERSONS
TRAINED AND EXPERIENCED IN THE USE AND
MAINTENANCE OF WELDING EQUIPMENT.
In the event of a warranty claim covered by this warranty, the
exclusive remedies shall be, at Miller’s option: (1) repair; or (2)
replacement; or, where authorized in writing by Miller in
appropriate cases, (3) the reasonable cost of repair or
replacement at an authorized Miller service station; or (4)
payment of or credit for the purchase price (less reasonable
depreciation based upon actual use) upon return of the goods at
customer’s risk and expense. Miller’s option of repair or
replacement will be F.O.B., Factory at ITW Welding Products
Group Europe or F.O.B. at a Miller authorized service facility as
determined by Miller. Therefore no compensation or
reimbursement for transportation costs of any kind will be
allowed.
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR
DIRECT,
INDIRECT,
SPECIAL,
INCIDENTAL
OR
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF
PROFIT), WHETHER BASED ON CONTRACT, TORT OR ANY
OTHER LEGAL THEORY.
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND
ANY
IMPLIED
WARRANTY,
GUARANTY
OR
REPRESENTATION AS TO PERFORMANCE, AND ANY
REMEDY FOR BREACH OF CONTRACT TORT OR ANY
OTHER LEGAL THEORY WHICH, BUT FOR THIS
PROVISION, MIGHT ARISE BY IMPLICATION, OPERATION
OF LAW, CUSTOM OF TRADE OR COURSE OF DEALING,
INCLUDING
ANY
IMPLIED
WARRANTY
OF
MERCHANTABILITY OR FITNESS FOR PARTICULAR
PURPOSE, WITH RESPECT TO ANY AND ALL EQUIPMENT
FURNISHED BY MILLER IS EXCLUDED AND DISCLAIMED
BY MILLER.
milan_warr 2016-01
Owner’s Record
Please complete and retain with your personal records.
Model Name
Serial/Style Number
Purchase Date
(Date which equipment was delivered to original customer.)
Distributor
Address
Country
Zip/Postal Code
For Service
Contact a DISTRIBUTOR or SERVICE AGENCY near you.
Always provide Model Name and Serial/Style Number.
Contact your Distributor for:
Welding Supplies and Consumables
Options and Accessories
Service and Repair
Replacement Parts
Owner’s Manuals
ITW Welding Italy S.r.l.
Contact the Delivering Carrier to:
File a claim for loss or damage during
shipment.
For assistance in filing or settling claims, contact
your distributor and/or equipment manufacturer’s
Transportation Department.
ORIGINAL INSTRUCTIONS − PRINTED IN USA
© 2016 Miller Electric Mfg. Co. 2016−01
Via Privata Iseo, 6/E
20098 San Giuliano
Milanese, Italy
Phone: 39 (0) 2982901
Fax: 39 (0) 298290-203
email: miller@itw−welding.it

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement