Dwyer | Series BBV-0 | Instruction manual | Dwyer Series BBV-0 Instruction Manual

Dwyer Series BBV-0 Instruction Manual
Bulletin V-BBV-0
Series BBV-0 2-Valve Block Manifold
By Dwyer
Specifications - Installation and Operating Instructions
INSTRUMENT
VENT
BBV-0F
ISOLATE
PROCESS
FLOW DIAGRAM
BBV-0N
The SERIES BBV-0 2-Valve Block Manifold is perfect for use over a broad range of
industrial applications including oil refineries, nuclear power stations, petrochemical
processing, and more. The Series BBV-0 is forged from 316 stainless steel bar stock
and designed to withstand repeated open and close operations. Suited to control oil,
water, toxic fluids, chemicals, air, and steam; the 2-valve block manifold has (1) isolate
and (1) vent valves. Each valve stem is precision machined with hard seats to reduce
operating torque.
The BBV-0F and BBV-0N are designed to mount directly to industrial pressure
transmitters. The BBV-0F comes with two 7/16-20 UNF mounting bolts and one PTFE
gasket.
INSTALLATION
Refer to the drawing shown above. The connections to the device must be made
accordingly. The BBV-0 2-Valve Block Manifold can be mounted in any position. The
BBV-0 is fitted with color-coded caps for valve identification:
ISOLATE (Blue)
VENT (Red)
The BBV-0 2-Valve Block Manifold require periodic maintenance. It is recommended
to change the sealing gaskets periodically for safety.
SPECIFICATIONS
Service: Compatible liquids, gases, or steam.
End Connections: Process connection: 1/2˝ male NPT; Instrument connection: No
flange: 1/2˝ female NPT; Flange: 1/2˝ DIN 19213 flange; Vent/test: 1/4˝ female NPT.
Wetted Materials: Body, stem, valve assembly: 316 SS; Stem packing: PTFE.
Pressure Limit: 6000 psi (400 bar).
Temperature Limit: 464°F (240°C).
Other Materials: Handle: 304 SS.
MAINTENANCE
After final installation of the block valve, some routine maintenance is required.
The Series BBV-0 is not field repairable, with the exception of previously stated
maintenance, and should be returned if repair is needed (field repair should not be
attempted and may void the warranty). Be sure to include a brief description of the
problem plus any relevant application notes. Contact customer service to receive a
return goods authorization (R.G.A.) number before shipping.
1. Do not remove the instrument from BBV-0 2-Valve Block
Manifold when the system is under pressure.
2. Do not remove the safety pin provided on the body.
3. Do not use the BBV-0 2-Valve Block Manifold above the recommended working
pressure and temperature given in the specifications.
CAUTION
W.E. ANDERSON
A DIVISION OF
DWYER INSTRUMENTS, INC.
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.
Phone: 219/879-8000
www.dwyer-inst.com
Fax: 219/872-9057
e-mail: info@dwyermail.com
DIMENSIONS
1-47/64
[44.00]
1-17/64
[32.00]
1/2˝ NPT PROCESS
CONNECTION
3-3/4
[95.00]
MAX OPEN
2X Ø15/32
MOUNTING HOLES
[Ø12.00]
3-15/64
[82.00]
1-5/8
[41.30]
2-23/64
[60.00]
4-41/64
[118.00]
3-5/8
[92.00]
MAX. OPEN
BBV-0F
4-17/32
[115.00]
1/4˝ NPT VENT
PORT (PLUGGED)
7-31/64
[190.15]
1-17/64
[32.00]
1/2˝ NPT FEMALE
1/2˝ NPT MALE
BBV-0N
©Copyright 2017 Dwyer Instruments, Inc.
W.E. ANDERSON
Printed in U.S.A. 5/17
A DIVISION OF
DWYER INSTRUMENTS, INC.
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.
FR# 443874-00 Rev. 2
Phone: 219/879-8000
dwyer-inst.com
Fax: 219/872-9057
e-mail: info@dwyermail.com