ADTRAN | Total Access 1500 | System Manual | Adtran Total Access 1500 System Manual

Adtran Total Access 1500 System Manual
Total AccessTM 1500 System Manual
Manual Part Number - 61180001L1-1A
CD Part Number - 3253036@A
61180001L1-1A
Total AccessTM 1500 System Manual
Trademarks
Any brand names and product names included in this manual are
trademarks, registered trademarks, or trade names of their respective
holders.
To the Holder of this manual
The contents of this manual are current as of the date of publication.
ADTRAN reserves the right to change the contents without prior notice.
In no event will ADTRAN be liable for any special, incidental or
consequential damages or commercial losses even if ADTRAN has been
advised thereof as a result of issue of this publication.
901 Explorer Boulevard
P.O. Box 140000
Huntsville, AL 35814-4000
(256) 963-8000
©2001 ADTRAN, Inc.
All Rights Reserved.
Printed in U.S.A.
Total AccessTM 1500 System Manual
61180001L1-1A
About this Manual
This manual provides a complete description of the system and
system software. The purpose of this manual is to provide the
technician, system administrator, and manager with general and
specific information related to the planning, installation, operation,
and maintenance of Total Access 1500. The manual is arranged so
that needed information can be quickly and easily found. The
following is an overview of the contents:
System Description
Provides users with an overview of the Total Access 1500 system.
Engineering Guidelines
Provides information to assist network designers incorporating a Total
Access 1500 system into their networks.
Application Guidelines
Provides information on specific Total Access 1500 wiring and
applications.
Certification
Total Access 1500 is compliant with all NEBS Level 3 requirements
and is listed to UL1950 3rd edition.
Federal Communications Commission Statement
This equipment generates, uses, and can radiate radio frequency
energy. If not installed and used in accordance with the instruction
manual, this equipment may cause interference to radio
communications. Total Access 1500 has been tested and found to
comply with limits for a Class A digital device pursuant to Subpart B
of Part 15 of FCC Rules, which are designed to provide reasonable
protection against such interference when operated in a commercial
environment.
This equipment does not exceed Class A limits for radio emission for
digital apparatus, set out in the Radio Interference Regulation of the
Canadian Department of Communications.
61180001L1-1A
Total AccessTM 1500 System Manual
Total AccessTM 1500 System Manual
61180001L1-1A
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 1 of 32
Total AccessTM 1500 System Description
This section of ADTRAN’s Total Access 1500 System Manual is designed for use by
network engineers, planners, and designers who are upgrading or intensifying a
communications network. It contains general information and describes physical and
operational concepts, card functions, network relationship, provisioning, testing, alarm
status, and system monitoring.
Contents
1.1 System Overview ................................................................................................................... 3
1.1.1
1.1.2
General Overview .............................................................................................................................. 3
Features and Benefits ....................................................................................................................... 4
1.2 System Components ............................................................................................................. 5
1.2.1
1.2.2
TA 1500 Shelf .................................................................................................................................... 5
Heat Baffle ......................................................................................................................................... 6
1.3 System Connectivity .............................................................................................................. 7
1.3.1
1.3.2
1.3.3
1.3.4
1.3.5
1.3.6
1.3.7
System and Power Ground ............................................................................................................... 7
Timing ................................................................................................................................................ 7
Network Interfaces ............................................................................................................................. 7
Loop Interface .................................................................................................................................... 7
Test Access ...................................................................................................................................... 10
Management Interface ..................................................................................................................... 10
Alarms .............................................................................................................................................. 10
1.4 Common Modules ................................................................................................................ 11
1.4.1
System Controller Unit ..................................................................................................................... 11
1.4.1.1 SCU Options ......................................................................................................................... 11
1.4.2 Line Interface Unit ........................................................................................................................... 12
1.4.3 PSU/RGU ........................................................................................................................................ 13
1.5 Access Modules ................................................................................................................... 15
1.5.1
1.5.2
1.5.3
1.5.4
1.5.5
1.5.6
1.5.7
1.5.8
1.5.9
1.5.10
1.5.11
FXS/DPO ......................................................................................................................................... 16
FXO/DPT ......................................................................................................................................... 17
E&M/TO ........................................................................................................................................... 19
Quad POTS (RT) ............................................................................................................................. 21
U-BR1TE ......................................................................................................................................... 22
OCU DP ........................................................................................................................................... 24
DS0 DP ............................................................................................................................................ 25
Dual FXS/DPO/PLAR ...................................................................................................................... 26
Dual FXS/DPT ................................................................................................................................. 27
Dual OCU DP ................................................................................................................................... 29
Dual DS0 DP .................................................................................................................................... 30
1.6 Bay Configurations .............................................................................................................. 31
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 2 of 32
Figures
Figure 1.
Figure 2.
Figure 3.
Figure 4.
Figure 5.
Figure 6.
Figure 7.
Figure 8.
Figure 9.
Figure 10.
Figure 11.
Figure 12.
Figure 13.
Figure 14.
Figure 15.
Figure 16.
Figure 17.
Figure 18.
Total Access 1500 ........................................................................................................ 5
TA 1500 Solutions ........................................................................................................ 6
TA 1500 Backplane .................................................................................................. 8, 9
SCU ........................................................................................................................... 11
LIU ............................................................................................................................. 12
PSU ........................................................................................................................... 13
FXS/DP0 .................................................................................................................... 16
FXO/DPT ................................................................................................................... 17
E&M / TO ................................................................................................................... 19
Quad R-POTS ........................................................................................................... 21
U-BR1TE ................................................................................................................... 22
OCU-DP..................................................................................................................... 24
DS0 DP ...................................................................................................................... 25
Dual FXS/DPO/PLAR ................................................................................................ 26
Dual FXS/DPT ........................................................................................................... 27
Dual OCU DP ............................................................................................................ 29
Dual DS0 DP ............................................................................................................. 30
Bay Configuration ...................................................................................................... 31
Tables
Table 1. Access Module Practices and Job Aids .......................................................................... 15
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 3 of 32
Total AccessTM 1500 System Description
1.1
System Overview
1.1.1
General Overview
The Total AccessTM 1500 (TA 1500) is a Carrier Class, Multi-service Access Platform
for deploying narrowband and xDSL services from TDM or ATM backbone
infrastructures. A small, extremely versatile platform, TA 1500 integrates the
functionality of many carrier products into a single high-density chassis. TA 1500’s
small footprint (2U-high mounting) makes it the perfect choice for integrated
communications providers such as ILECs, CLECs, and ISPs, who need to deploy
services from crowded Remote Terminals (RTs), Central Offices (COs), or CoLocation (COLO) facilities.
TA 1500 provides a variety of services including POTS, special services (ISDN, DDS,
FXO, FXS, E&M, DPO, DPT, and PLAR), and xDSL. TA 1500 complements
ADTRAN’s Total Access 3000 broadband multi-service access platform, which can
terminate and distribute higher bandwidth services such as SONET, DS3, HDSL,
HDSL2, T1, Optical DS2, and xDSL. TA 1500 can be deployed as a:
•
Small Digital Loop Carrier (DLC), for simple and effective deployment of
POTS (up to 96 lines in a 2U mounting).
• Special Services delivery platform, with up to five times the density of any
competing D4 platform.
• Mini-DSLAM, serving up to 24 xDSL customers (POTS and data) using an
ATM network interface.
TA 1500 is a modular device, with five common slots and 24 access slots. Common
units required for operation are a Power Supply Unit (PSU), Line Interface Unit (LIU),
and System Controller Unit (SCU). A second, redundant PSU and LIU may be
deployed for added reliability. The PSU is available with an integrated Ring
Generator providing up to 20 REN ringing capacity. The LIU can support up to four
T1 interfaces and has full Time Slot Assignment (TSA) capability. This feature allows
users to “steer” varied amounts of bandwidth from the network to any of the access
slots, ensuring that no bandwidth is stranded. Future LIUs will provide HDSL2, fiber,
and ATM interfaces. The 24 access slots accept a variety of voice and data access
modules, allowing users to optimize their service for each application.
Using local or remote inband management, service providers can provision and
monitor the bank’s network interface and access modules. Transaction Language 1
(TL1) is used to communicate with Telcordia’s NMATM Operations System
(OSS) using an internal X.25 PAD. An Ethernet 10BASE-T connector is used
for connection to SNMP networks. ADTRAN’s Total Access EMSTM
software, run on an Openview workstation, provides a graphical user interface
(GUI).
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 4 of 32
TA 1500 is designed for 23-inch relay racks. Full compliance with NEBS
Level 3 and UL 1950 ensures maximum reliability and safety.
1.1.2
Features and Benefits
•
•
•
•
•
•
•
•
•
•
•
•
POTS, specials, and xDSL
Access to TDM and ATM Networks.
Up to 96 two-wire interfaces.
Extremely small (2U) mounting for crowded COs or RTs.
Fully redundant common units
TR-08 signaling and is fully compatible with SLC“-96 COT/RT.
Up to five times as dense as a D4 channel bank when used for specials.
A TL1 interface to NMA over X.25
SNMP management
Mechanized Loop Testing (MLT)
NEBS Level 3 and UL 1950
Industry-leading 10-year warranty
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 5 of 32
1.2
System Components
Total Access 1500 is composed of five main elements:
Total Access 1500 Shelf and Backplane
System Controller Unit
Power Supply Unit
Line Interface Unit
Access Modules
•
•
•
•
•
1.2.1
TA 1500 Shelf
The system houses the management, network interface, and access modules. The
compact shelf includes all the features necessary for total system functioning including
provisioning, protection, monitoring, alarm status, and testing. The single
multifunction backplane provides for a variety of system arrangements.
ADTRAN’s Total Access 1500 shelf is compliant with all applicable NEBS Level 3
requirements and listed to UL 1950 3rd edition.
All modules are inserted and removed from the front of the shelf. The two far left
slots are designated for the Power Supply Units (PSU). The next slot is designated for
the System Controller Unit (SCU). The next two slots are designated for the Line
Interface Units (LIU). The remaining 24 slots are reserved for access modules. Slot
openings are labeled for easy identification (see Figure 1.)
The 3.5-inch high, 12-inch deep, 23-inch wide shelf is constructed of heavy gauge
metal with vent perforations on the top and bottom planes. Reversible mounting
brackets allow for flush mount or 5-inch overhang configurations. Mounting brackets
meet both 1-inch and 1 3/4-inch mounting hole pattern.
1500
SCU
LIU
1180008L2
LIU
1180109L1
1180109L1
A
T
I
M
I
N
G
C
R
A
F
T
MJR
HST
MNR
MLT
BSY
R
C
D
P
RCV
REM
TEST
MASTER
STATUS
PSU-B
SCU
PSU-A
STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
REM
REM
REM
REM
REM
REM
REM
REM
REM
REM
REM
REM
REM
REM
REM
REM
REM
REM
REM
REM
REM
REM
REM
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
1180403L1
1180403L1
1180403L1
1180403L1
1180403L1
1180403L1
1180403L1
1180403L1
1180403L1
1180403L1
1180403L1
1180403L1
1180403L1
1180403L1
1180403L1
1180403L1
1180403L1
1180403L1
1180403L1
1180403L1
1180403L1
RED
RCV
REM
TEST
MASTER
STATUS
TX
RX
MONITOR
FXS/DPO FXS/DPO FXS/DPO FXS/DPO FXS/DPO FXS/DPO FXS/DPO FXS/DPO FXS/DPO FXS/DPO FXS/DPO FXS/DPO FXS/DPO FXS/DPO FXS/DPO
1180403L1
D
P
YEL
TX
ACO
FXS/DPO FXS/DPO FXS/DPO FXS/DPO FXS/DPO FXS/DPO FXS/DPO FXS/DPO
1180403L1
R
C
RED
YEL
RMT
PSU-A
A
RX
MONITOR
LIU-B
1
2
3
4
5
6
7
8
9
10
11
12
14
15
16
17
18
19
20
21
22
23
24
Figure 1. Total Access 1500
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 6 of 32
1
2
3
4
5
Total Access 1500 is the foundation for an intelligent, versatile voice and digital
services system. It is the basic building block for both metallic and optical
transmission service between the customer and the service provider’s facility. Figure 2
shows the Total Access 1500 with management, network, loop devices, and interfaces.
Built-in
PAD
HD-10 BRI Mux HD-10 BRI Mux HD-10 BRI Mux HD-10 BRI Mux HD-10 BRI Mux
QFC-C QFC-C QFC-C QFC-C
1181200L1
1181200L1
1181200L1
1181200L1
POWER
POWER
DSX
DSX
LBK
LBK
1181200L1
1181300L1
PWR
LBK
1181300L1
1181300L1
PWR
DSX
#1
DSX
#2
DSX
#3
DSX
#4
PWR
DSX
#1
DSX
#2
DSX
#3
DSX
#4
1181300L1
#1
DSX
#2
DSX
#3
DSX
#4
DSX
#1
DSX
#2
DSX
#3
DSX
#4
TST
TST
TST
ALM
ALM
ALM
ALM
T1-OR T1-OR
1181310L1
PWR
PWR
DSX
TST
1181310L1
PWR
DSX
R
X
R
X
X
TST
LP1
T
R
— X
X
6V
1181101L1
DSX
+
R
HTU-C
PWR
ALM
T
— X
6V
1181310L1
LP
+
T
— X
6V
LBK
ALM
+
T
— X
DSX
LP
ALM
+
PWR
LBK
LP
ALM
1181310L1
DSX
LBK
LP
T1-OR T1-OR
PWR
DSX
LBK
6V
HTU-C
1181101L1
PWR
DSX
TST
LP1
HTU-C
1181101L1
PWR
DSX
TST
LP1
HTU-C
1181101L1
PWR
DSX
TST
LP1
HTU-C
1181101L1
PWR
DSX
TST
LP1
HTU-C
1181101L1
PWR
DSX
TST
LP1
HTU-C
1181101L1
PWR
DSX
TST
LP1
HTU-C
1181101L1
PWR
DSX
TST
LP1
HTU-C
1181101L1
PWR
DSX
TST
LP1
HTU-C
1181101L1
PWR
HTU-C
1181101L1
PWR
DSX
DSX
TST
TST
LP1
LP1
HTU-C
1181101L1
PWR
DSX
TST
LP1
HTU-C
1181101L1
PWR
DSX
TST
LP1
HTU-C
1181101L1
PWR
DSX
TST
LP1
LP2
LP2
LP2
LP2
LP2
LP2
LP2
LP2
LP2
LP2
LP2
ALM
LP2
ALM
LP2
ALM
LP2
ALM
ALM
ALM
ALM
ALM
ALM
ALM
ALM
ALM
ALM
ALM
FNID
1245201L1
ISU Express
TEST
RS
CS
TD
RD
CD
TR
RI/OH LOC REM LOOP PWR
SELECT
TEST
DSL
DS1
ESF
SF
(YEL)
(GRN)
B8ZS
AMI
(YEL)
(GRN)
LBK
L
B
K
LOC
REM
TX
M
O
N
RX
R
S
2
3
2
Figure 2. TA 1500 Solutions
1.2.2
Heat Baffle
An optional heat baffle mounts directly above the main shelf. It allows passage of hot
air to convect heat away from the shelf above the baffle.
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 7 of 32
1.3
System Connectivity
The TA 1500 fits in the standard 23-inch rack. The multifunction single backplane is
the key element in system versatility. It contains all I/O connectors, control and signal
routing, power input and ground, plus the interconnections between access modules
and the common cards. There are also facilities for plug-in modules and wire-wrap
pins for special purposes.
Refer to Figure 3, Total Access 1500 Backplane, to identify the locations of the
following:
1.3.1
System and Power Ground
1. Power Connections (TB1)
The system is designed to accommodate redundant power configurations.
Dual Terminals for -48V, return, and frame ground are provided. The system
will operate with each individual supply or both supplies functioning.
2. Ring Generator (TB2)
The system operates with either an internal or external ring generator. For external
ring generator applications, TB2 provides connections for ringing voltage, ringing
return, and frame ground.
1.3.2
Timing
1. Composite Clock (P14)
For applications requiring external timing sources, a composite clock interface is
available. SW1 allows the user to designate which bank is terminating composite
clock.
1.3.3
Network Interfaces
1. T1 Connections (P7, P8, P9, P10, P11)
Four T1s plus a protect T1 are available. A frame ground connection is provided
for each T1.
1.3.4
Loop Interface
1. Loop Access (P1, P2, P3, P4)
Loop side access is achieved via 50-pin amphenol connectors.
2. PGTC Connector (P5)
The Pair Gain Test Controller (PGTC) connector provides a 28-wire interface to
the Central Office PGTC. The Central Office PGTC permits customer loops
served by loop carrier systems to be tested from a maintenance center using
Mechanized Loop Testing (MLT).
1.3.5
Test Access
1. Loop Test Access (P6)
Four wire-wrap connections provide a metallic loop test bypass pair.
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
40
30
21
40
30
J24
J24
IN
CLK
20
10
1
40
20
P1
30
10
R1
21
21
P1
P1
40
30
25
20
10
1
C2
+
40
30
25
50
20
10
1
LOCCK
–
T/R
J21
CLK IN
21
1
40
30
21
CLK OUT
C1
TERM
OUT
PAIR 1
20
40
20
50
10
1
–
PAIR 1
20
10
1
40
30
21
B
ACO
A
20
10
1
–
40
30
21
B
RMT
A
40
30
21
CLK OUT
+
J20
CLK IN
21
30
C2
C1
J22
10
1
SW1
J23
R1
1
J23
21
J22
B
1
26
AUX1
A
J19
B
–
40
30
21
20
10
1
J18
40
30
21
B
40
30
21
ACO
A
20
10
1
J17
20
10
1
40
30
40
30
21
B
1
26
J15
20
10
1
T1 / R1
40
30
B
40
30
21
17
P14
P14
20
10
21
40
30
21
40
30
21
1
26
20
10
1
ALM
-48
40
30
21
17
J12
P2
P2
20
10
1
40
30
21
J11
25
50
40
30
21
40
30
25
50
40
30
21
PAIR 2
20
10
1
20
10
1
1
26
20
10
1
20
10
1
T1 / R1
40
30
21
20
10
1
40
30
21
AUX
40
30
21
AMN
20
10
1
AMJ
40
30
21
NO COM NC
E / SG
J8
NO COM NC
40
30
21
J7
NO COM NC
PAIR 3
20
10
1
1
26
20
10
1
ALM
-48
40
30
21
J34
MGMT
40
30
40
30
21
T
1
17
21
20
10
1
1
R
P4
20
10
1
20
10
1
T1 R1
A
P11
5
40
30
21
T
1
R
40
30
40
30
21
5
T
1
20
20
10
1
5
P3
P3
40
30
21
M / SB
40
30
21
1
10
T1 R1
C
P9
R
A
B
RS485
P12
P12
PAIR 4
20
10
1
T1 R1
B
P10
21
25
50
J3
DIS
SW2
VMN
20
10
1
RS485
VMJ
P3
40
30
21
EN
NO COM NC
20
10
1
A
B
RS485
J10
NO COM NC
21
1
P13
P13
20
10
1
P12
J6
Figure 3. TA 1500 Backplane (Left)
20
10
1
20
10
1
AUX
AMN
AMJ
1
NO COM NC
NO COM NC
NO COM NC
AUX2
A
40
30
PAIR 2
AUX1
A
25
50
20
10
21
VMN
VMJ
1
NO COM NC
NO COM NC
21
B
RMT
A
P2
20
10
1
1
J2
P13
20
10
1
R
EN
T
1
T1 R1
D
P8
1
5
20
1
26
20
10
25
50
40
30
21
30
SW2
DIS
40
20
10
1
T1 R1
P
J31
P7
R
1
T
RS485
1
40
21
P14
17
LOCCK
+
20
10
1
AUX2
A
T/R
J21
J16
+
J20
J14
J18
–
J19
J13
+
J5
–
J16
J4
J12
+
J17
J9
J15
10
1
J11
J32
30
OUT
J10
E
D
C
B
A
PAIR 3
5
J30
20
10
1
20
10
1
J29
J33
20
10
E
D
C
B
40
30
21
P5
E
D
C
B
A
TERM
J14
O
N
J13
20
10
1
E / SG
24
RN1
RN2
J8
21
J9
R
P6
I
24
20
10
25
50
40
30
21
30
TB
PGTC
1
J28
B Y PA S S
T
E
D
C
B
A
40
IN
J27
20
10
1
20
10
SW1
J7
RTN
1
26
30
21
40
IN
R
T
N
I
N
40
-48 SEC
3 TB2
SMAS
MLT
-48 SEC
10
20
10
1
20
RTN
J26
30
IN
J6
D2
1
26
D1
40
30
21
MGMT
40
21
J34
J34
5
J25
1
20
20
10
1
30
2001, ADTRAN, Inc.
10
O
N
O
N
J5
O
N
CLK
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 8 of 32
Total AccessTM 1500 System Manual
J1
20
40
21
P1
40
30
J23
40
P3
P3
20
40
20
30
10
10
30
21
1
T/R
20
40
1
10
J21
30
21
EN
10
1
20
PAIR 1
21
A
B
RS485
25
50
40
20
21
30
C2
C1
10
1
1
P12
P12
10
J24
30
1
J22
–
20
10
25
50
40
30
21
RS485
1
SW2
20
40
DIS
10
1
PAIR 3
20
10
1
40
30
21
B
RMT
A
30
21
B
ACO
A
B
1
26
AUX1
A
J19
+
B
40
30
21
20
10
1
AUX2
A
40
30
21
J18
E / SG
20
10
1
20
10
1
40
30
21
J17
40
30
21
P2
20
10
1
40
30
25
50
20
10
1
VMJ
40
30
21
VMN
40
1
26
30
21
20
10
1
40
30
21
40
30
21
MGMT
J34
J34
40
30
-48
20
10
1
1
26
20
10
1
ALM
1
40
30
21
J12
40
30
21
T
1
17
40
30
21
J11
R
P4
P4
20
10
1
T1 R1
A
P11
P11
20
10
1
P12
5
20
10
1
40
30
21
40
30
21
T
1
P3
A
B
RS485
25
50
40
30
DIS
SW2
PAIR 3
25
50
PAIR 4
20
10
1
T1 R1
B
P10
P10
20
10
21
RS485
1
R
EN
40
30
21
5
20
10
1
T
1
40
30
21
J8
40
30
21
20
M / SB
40
30
21
10
T1 R1
C
1
J7
R
P9
P9
E / SG
20
10
1
5
20
10
1
R
10
1
J6
20
1
26
T
1
40
30
21
40
30
21
40
T1 R1
D
P8
P8
20
10
1
J34
MGMT
1
5
20
10
1
20
1
R
R
1
26
5
40
30
30
40
20
10
1
T1 R1
P
T
1
21
P7
P7
P4
20
10
1
T1 R1
A
P11
J31
T
1
40
30
21
T
1
R
25
50
5
5
40
30
21
20
10
1
PAIR 4
20
10
1
T1 R1
B
P10
T
1
J29
J33
M / SB
40
J33
20
30
21
1
10
T1 R1
C
P9
R
20
10
5
T
1
P5
P5
24
J1
10
1
R
20
Figure 3. TA 1500 Backplane Continued (Right)
20
10
1
20
10
21
AUX
AMN
1
NO COM NC
NO COM NC
T1 / R1
AMJ
NO COM NC NO COM NC
PAIR 2
20
10
1
NO COM NC
21
1
J9
P13
T1 R1
D
P8
40
21
P14
17
J8
21
J10
J20
J9
J16
LOCCK
J7
–
J14
+
J15
J6
R1
J11
J13
CLK OUT
J5
–
J4
J10
J3
1
5
20
10
+
J1
1
R
J31
T
1
26
30
T
5
R
25
50
J33
J29
I
24
20
10
PGTC
30
40
TB1
TB
P5
24
P16
1
J28
20
10
P6
P6
20
10
1
B Y PA S S
40
20
10
1
T1 R1
P
P7
21
CLK IN
J2
J3
J30
E
D
C
B
A
E
D
C
B
E
D
C
B
A
J32
30
RN1
RN2
R
P6
20
I
24
20
10
40
20
R
T
N
I
N
TB2
RTN
40
IN
20
R
T
N
I
N
20
1
P17
1
26
D2
26
P15
40
-48 SEC
3 TB2
SMAS
MLT
-48 SEC
-48 SEC
3 TB2
SMAS
MLT
-48 SEC
25
50
30
TB
PGTC
1
J28
B Y PA S S
T
E
D
C
B
A
RTN
IN
J27
10
1
IN
RTN
J26
30
OUT
J32
30
RTN
5
5
21
40
J25
30
20
1
40
21
TERM
D1
D1
SW1
21
J5
10
J4
E
D
C
B
A
21
J2
E
D
C
B
E
D
C
B
A
J30
E
D
C
B
A
RN1
RN2
IN
J27
10
10
J25
IN
10
J26
30
10
D2
Total AccessTM 1500 System Manual
30
O
N
O
N
20
1
10
O
N
CLK
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 9 of 32
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 10 of 32
1.3.6
Management Interfaces
1. SCU Management Port (J34)
DB-25 female connector allows port access for an X.25 connection.
2. RJ-45 for 10 Base-T (J33)
RJ-45 jack provides for SNMP and IP/LAN communication over 10Base-T.
3. RS-485 (P12)A set of wire-wrap pins provides a bus for intershelf
management. Up to 15 additional devices can be daisy chained to the first shelf at
a total distance of 4000 feet.
4. SMAS or MLT (P15, P16, P17)
Jumpers allow loop testing through MLT or SMAS. The default setting is MLT.
1.3.7
Alarms
1. Alarm Outputs (P13)
The shelf provides for six alarm outputs:
• Major Visual
• Major Audible
• Minor Visual
• Minor Audible
• -48ALM
• AUX
Each alarm, except -48ALM, can be individually wired for normally open or
normally closed configuration. -48ALM is normally an open circuit and
applies -48 V when the PSUs fuse opens.
2. Alarm Input (P14)
The shelf contains four external alarm inputs: Alarm Cutoff, Remote, AUX1, and
AUX 2. All alarms are -48 V active or relay closure.
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 11 of 32
1.4
Common Modules
1.4.1
System Controller Unit
The System Controller Unit (SCU) serves as the user interface into the system. (See
Figure 4.) The operator provisions and monitors other modules in the system, either
locally or remotely, via the SCU.
SCU
1180008L2
T
I
M
I
N
G
C
R
A
F
T
MJR
HST
MNR
MLT
BSY
RMT
ACO
Figure 4. SCU
1.4.1.1
SCU Options
The SCU provisions the Access modules in the shelf via the faceplate
DB-9 connector and a VT100 terminal. Up to 16 systems can be daisychained together via the RS-485 interface (P12).
The SCU incorporates these features:
•
Daisy-chained system communication link
•
Automatically recognizes all access module
technologies
•
Major, and minor alarm hierarchy
•
Multiple provisioning capability for all access and
management modules
•
Hot Swappable
•
Ethernet interfaces via a RJ-45 port.
•
Mechanized Loop Test (MLT) capability.
The faceplate also includes status LEDs for local module status, monitoring, and
provisioning.
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 12 of 32
1.4.2
Line Interface Unit
The LIU is a common card plug-in for the ADTRAN TA 1500 channel bank. (See
Figure 5.) It connects the channel bank to a T1 line at the DSX-1 or DS1 level. All
data formatting and line encoding as well as backplane timing and control are
performed by the TA 1500 LIU.
The LIU incorporates these features:
• Four T1s + protect
• SF, ESF, or SLC-96 (TR-08) framing formats
• AMI or B8ZS line code formats
• Local and remote loopbacks
• Front panel Bantam jacks for monitoring T1s
• Front panel indicators showing the status of the unit
• Local, loop, or external timing modes
The faceplate includes status LEDs and a status pushbutton for local module status,
monitoring, and provisioning.
LIU
1180109L1
A
B
C
D
P
RED
YEL
RCV
REM
TEST
MASTER
STATUS
TX
RX
MONITOR
Figure 5. LIU
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 13 of 32
1.4.3
PSU/RGU
The PSU/RGU is a common module plug-in unit designed for use in the ADTRAN TA
1500 channel bank. (See Figure 6.) The PSU/RGU receives -48 Vdc from an external
source to provide all necessary voltages required by the other common modules and
access channel units. Through switchmode operation the PSU converts the incoming 48 Vdc to regulated +5 Vdc, +3.3 Vdc and unregulated -7.5 Vdc, -26 Vdc, and 48 Vdc for distribution to other modules. Two versions of the PSU/RGU are
available. The 1180007L2 allows the system to operate utilizing an external ring
generator. The 1180007L1 contains circuitry within the PSU that generates 105 Vrms
nominal, 20 Hz ring voltage for distribution to the channel bank’s voice cards.
Removing the 20 Hz, 5-amp GMT faceplate fuse disables ring voltage. Two PSU/
RGUs may be installed to provide fully redundant operation.
The PSU incorporates these features:
• Receives unregulated power input.
• Generates 20 Hz ring voltage (List 1 only).
• Faceplate mounted input power fuse
• Faceplate mounted ring voltage disconnect
• Faceplate status LEDs
• Provision free plug-and-play
The faceplate also includes LEDs for local module status.
Figure 6. PSU
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 14 of 32
This page intentionally left blank.
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 15 of 32
1.5
Access Modules
Total Access 1500 incorporates a complete array of local loop access technologies into
an integrated intelligent system. Most access modules occupy one slot in the Total
Access shelf.
The access technologies and devices supported by Total Access 1500 are listed in
Table 1. Refer to individual Practices and Job Aids for detailed information on
installation, testing, operation, maintenance, and troubleshooting.
Table 1. Access Module Practices and Job Aids
Access Module Device
FXS/DPO
FXO/DPT
E&M/TO
Quad POTS (RT)
UB-R1TE
OCU DP
DS0 DP
Dual FXS/DPO
Dual FXO/DPT
Dual OCU DP
Dual DS0 DP
Total AccessTM 1500 System Manual
Job Aid
Practice
61180403L1-22
61180404L1-22
61180402L1-22
61180408L1-22
61180020L1-22
61180005L1-22
61180003L1-22
61180208L2-22
61180207L2-22
61180205L2-22
61180203L2-22
61180403L1-5
61180404L1-5
61180402L1-5
61180408L1-5
61180020L1-5
61180005L1-5
61180003L1-5
61180208L2-5
61180207L2-5
61180205L2-5
61180203L2-5
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 16 of 32
1.5.1
FXS/DPO
The Total Access 1500 Foreign Exchange Service/ Dial Pulse Originate (FXS/DPO)
unit is used for analog voice extension and DID circuits. (See Figure 7.) Additionally,
it offers private line automatic ringdown (PLAR) functionality.
BUSY
REM
AP
Figure 7. FXS / DP0
The FXS/DPO is designed specifically for the ADTRAN Total Access 1500 chassis
and is not used in any other product. The unit is multifunctional and can be
provisioned to operate in any one of the following modes:
•
•
•
•
2-Wire Foreign Exchange Station (FXS)
Dial Pulse Originate (DPO)
Tandem Mode
Private Line Automatic Ringdown (PLAR)
The FXS/DPO module incorporates these features:
• Individual analog voice interface
• µ-law encoding and decoding
• Ground start, loop start, and TR-08 signaling.
• Long loop capability – 1250 ohms (nominal) including telephone set
(16 kft @ 24 AWG).
• Hot Swappable
• Supports V.90 Modem rates.
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 17 of 32
•
•
•
•
•
•
•
•
Supports CLASSTM features such as Caller ID.
Transmit TLP range of -7.0 dBm to +9.0 dBm
Receive TLP range of -9.0 dBm to 0.0 dBm
Selectable 600W +2.16µF or 900W +2.16µF 2-wire VF interface.
Occupies a single slot in the TA 1500 chassis.
Meets PUB 43801 standards.
NEBS Level 3 and UL 1950 compliant.
Extended temperature range of -40 to +65º
The Faceplate LED indicators include:
• BUSY
• REM
The Other faceplate features include:
• Alternate (remote) provisioning switch
1.5.2
FXO/DPT
The Total Access 1500 Foreign Exchange Office/Dial Pulse Termination (FXO/DPT)
unit is used for analog voice extension and DID circuits. (See Figure 8.)
FXO/DPT
1180404L1
BUSY
REM
AP
Figure 8. FXO / DPT
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 18 of 32
The FXO is designed specifically for the ADTRAN Total Access 1500 chassis and is
not used in any other product. The unit is multifunctional and can be provisioned to
operate in one of the following modes:
•
•
2-Wire Foreign Exchange Office (FXO)
Dial Pulse Terminate (DPT)
The FXO/DPT module incorporates these features:
• Individual analog voice interface
• µ-law encoding/decoding
• Ground start, loop start signaling, and TR-08 signaling.
• Hot swappable
• Supports V.90 modem rates.
• Supports CLASS™ features.
• Transmit TLP of -7.0 dBm to +9.0 dBm
• Receive TLP of -9.0 dBm to 0.0 dBm
• Nominal 600 Ω or 900 Ω (+ 2.15 µF) 2-wire voice frequency (VF) interface with
DC isolation
• Meets Bellcore PUB 43801.
• Supports CLASS services.
• Meets NEBS Level 3 and UL 1950 standards.
• Extended temperature range: -40º to 65º C
The Faceplate LED indicators include:
• BUSY
• REM
Other faceplate features include:
• Alternate (remote) provisioning switch
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 19 of 32
1.5.3
E&M/TO
The Ear and Mouth/ Transmit Only (E&M/TO) is used primarily for PBX applications.
(See Figure 9.)
Figure 9. E&M / TO
The E&M/TO is designed specifically for the ADTRAN Total Access 1500 chassis
and is not used in any other product. The unit is multifunctional and can be
provisioned to operate in any one of the following modes:
•
•
•
•
2-wire E&M
2-wire TO
4-wire E&M
4-wire TO
The E&M/TO module incorporates these features:
• 600 W (4-wire) or 600 W + 2.2 µF (2-wire) VF interface with DC isolation
• Transmit TLP range:
2-wire: –9.0 dBm to 0.0 dBm
4-wire: –17.5 dBm to –5.5 dBm
• Receive TLP range:
2-wire: –9.0 dBm to 0.0 dBm
4-wire: –3.5 dBm to +8.5 dBm
• Compatible with Types I, II, III or V E&M signaling interfaces.
• Extended operating temperature range from –40° C to +65° C for deployment in
RT’s.
• Meets UL 1950, NEBS Level 3, and PUB 43801 standards.
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 20 of 32
The Faceplate LED indicators include:
• STATUS
• REM
Other faceplate features include:
• Alternate (remote) provisioning switch
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 21 of 32
1.5.4
Quad R-POTS
The Total Access R-POTS unit provides four independent interfaces for POTS
circuits. (See Figure10.)
R-POTS
1180408L1
BUSY
1
2
3
4
Figure 10. Quad R-POTS
The Quad R-POTS module incorporates these features:
• Four VF interfaces
• PCM voice interface (digital), with µ-law 255 data encoding/decoding
• Support loop start, ground start, andTR-08 signaling.
• Nominal 900 Ω (+ 2.16 µF) 2-wire and 600 Ω (+2.16 µF) 2-wire voice frequency
(VF) interface with DC isolation
• Digital loopback towards network
• Transmit TLP range of +9.0 dBm to -7.0 dBm
• Receive TLP range of –9.0 dBm to 0.0 dBm
• Caller ID CLASS compatible.
• Extended temperature range: -40º to 65º C for deployment in RT’s
• Supports FXS, DPO, PLAR, and Tandem.
• Meets NEBS Level 3, UL, and TA-NWT-000057 standards.
• Supports MLT.
Faceplate LED indicators include:
• BUSY
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 22 of 32
1.5.5
U-BR1TE
The U-BR1TE is an access module that plugs into a single channel slot of a Total
Access 1500 channel bank. (See Figure 11.) It provides an ISDN U-interface and
allows the transport of Basic Rate 2B+D information over T1 carrier and twisted pair
wiring. Clear channel capability (B8ZS) is not required of the T1 facility if zero byte
substitution is enabled.
U-BR1TE
1180020L1
STATUS
REM
AP
RX
TX
LOGIC
Figure 11. U-BR1TE
The U-BR1TE module incorporates these features:
• ISDN 2B1Q interface that meets all Layer 1 requirements as specified in ANSI
T1.601-1991
• 18 kft nominal range on mixed gauge wire
• Internal test pattern allows for testing of individual B Channels without requiring
external test equipment.
• Transportation of ISDN Basic Rate 2B+D information over T1 facilities in the
3-DS0 format specified in TR-NWT-000397.
• All Layer 1 maintenance functions
• Performance monitoring of the Layer 1 facility as specified in TR-NWT-000397
and TR-TSY-000829
• Distinctive metallic DC test signature to identify either line unit LT or line unit NT
mode of operation as specified in TR-NWT-000397.
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 23 of 32
•
•
•
•
•
Loopback capability for full 2B+D as well as individual B channels in both loop
and carrier directions. Individual B channel loopbacks may be initiated via the
DB-9 VT100 craft interface on the TA 1500 SCU, or from a remote location
through the maintenance channel.
B1 and B2 loopback addressability at the faceplate for the NT1 and up to six
devices in the Network-to-Customer direction.
DS0 logic level transmit and receive data access through faceplate bantam jacks.
A built-in Cyclic Redundancy Check (CRC) clock error detector allows for local
performance monitoring at the faceplate without test equipment.
Addressing and error status with front panel LED indicators.
Faceplate LED indicators include:
• STATUS
• REM
Other faceplate features include:
• Alternate (remote) provisioning switch
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 24 of 32
1.5.6
OCU DP
The Office Channel Unit Dataport (OCU DP) is a Total Access 1500 channel unit (See
Figure 12.) The OCU DP provides the interface between a DS0 timeslot of the Tcarrier data stream and the 4-wire metallic loop to the customer’s premises. The OCU
DP may interoperate over the carrier system with another OCU DP, DS0 DP, DS0
cross-connect system, or switch, and may be located in an end office, hub office,
intermediate office, or remote digital terminal system.
Figure 12. OCU-DP
The OCU DP incorporates these features:
• NEAR and FAR logic level Bantam test access
• Non-intrusive monitoring of received data from NEAR or FAR direction.
• Loop Quality Monitor and A/B signaling options
• Remotely provisionable; Performance Monitoring via Digital System-6.
Faceplate LED indicators include:
• STATUS
• REM
Other faceplate features include:
• Signal Jacks
• Alternate (remote) provisioning switching
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 25 of 32
1.5.7
DS0 DP
The Digital Signal Zero Dataport (DS0 DP) is a Total Access channel unit (see Figure
13.) Is used in the Dataphone Digital Service (DDS) to interface the basic DDS DS0
(64 kbps) signal to a T-carrier line. The DS0 DP is generally located in either a hub or
intermediate office. It is used in conjunction with an ADTRAN All-Rate Office
Channel Unit (OCU) dataport or Total Reach DDS dataport located at the end office to
extend the DDS network to an end office that had exclusively served voice channels.
Figure 13. DS0 DP
The DS0 DP incorporates these features:
• Sub-rate, 19.2, 38.4, 56, and 64 kbps Clear Channel operation; Subrate Error
Correction, Zero Code Suppression and Latching Loopback
• The dataport can be optioned to operate as a DS0 DP or as a Clear Channel Unit
(CCU.)
• Switched 56 Tandem functionality
• Logic level test access: non-intrusive receive monitoring capability
Faceplate LED indicators include:
• STATUS
• REM
Other faceplate features include:
• Signal Jacks
• Alternate (remote) provisioning switch
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 26 of 32
1.5.8
Dual FXS/DPO/PLAR
The Total Access Foreign Exchange Service/ Dial Pulse Originate/ Private Line
Automatic Ringdown (FXS/DPO/PLAR) unit is used for analog voice extension
and DID circuits (See Figure 14.) Additionally, it offers private line automatic
ringdown (PLAR) functionality.
Figure 14. Dual FXS/DPO/PLAR
The Dual FXS/DPO/PLAR is designed specifically for the ADTRAN Total Access
1500 chassis and is not used in any other product. The unit is multifunctional and can
be provisioned to operate in any one of the following modes:
• 2-Wire Foreign Exchange Station (FXS)
• Dial Pulse Originate (DPO)
• Tandem Mode
• Private Line Automatic Ringdown (PLAR)
The Dual FXS/DPO/PLAR module incorporated these features:
• Individual analog voice interfaces.
• µ-law encoding and decoding
• Ground start, loop start and TR-08 signaling
• Long loop capability -1500 ohms (nominal) including telephone set (16 kft @ 24
AWG).
• Hot Swappable
• Supports V.90 Modem rates.
• Supports CLASS™ features such as Caller ID.
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 27 of 32
•
•
•
•
•
•
•
Transmit TLP range of -7.0 dBm to + 9.0 dBm
Receive TLP range of -9.0 dBm to 0.0 dBm
Selectable 600 Ω +2.16mF or 900 Ω +2.16mF 2-wire VF interface.
Occupies a single slot in the TA 1500 chassis.
Meets PUB 43801 standards.
NEBS Level 3 and UL 1950 compliant.
Extended temperature range of -40° to +65∞ C
The Faceplate LED indicators include:
• STATUS (1 and 2)
1.5.9
Dual FXO/DPT
The Total Access 1500 Dual Foreign Exchange Office/Dial Pulse Termination
(FXO/DPT) unit is used for analog voice extension and DID circuits.
(See Figure 15.)
Figure 15. Dual FXO/DPT
The Dual FXO/DPT is designed specifically for the ADTRAN Total Access 1500
chassis and is not used in any other product. The unit is multifunctional and can
be provisioned to operate in one of the following modes:
• 2-Wire Foreign Exchange Office (FXO)
• Dial Pulse Terminate (DPT)
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 28 of 32
The FXO/DPT module incorporated these features:
• Individual analog voice interfaces
• µ-law encoding/decoding
• Ground start, loop start signaling, and TR-08 signaling
• Hot Swappable
• Supports V.90 modem rates.
• Supports CLASS™ features.
• Transmit TLP of -7.0 dBm to +9.0 dBm
• Receive TLP of -9.0 dBm to 0.0 dBm
• Nominal 600Ω or 900Ω (+ 2.15 uF) 2-wire voice frequency (VF) interface with
DC isolation.
• Meets Bellcore PUB 43801.
• Supports CLASS™ services.
• Meets NEBS Level 3 and UL 1950 standards.
• Extended temperature range: -40° to 65∞ C
The Faceplate LED indicators include:
• STATUS (1 and 2)
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 29 of 32
1.5.10 Dual OCU DP
The Dual Office Channel Unit Dataport (OCU DP) is a Total Access 1500 channel unit
(See Figure 16.) The Dual OCU DP provides the interface between a DS0 timeslot of
the T-carrier data stream and the 4-wire metallic loop to the customer’s premises. The
Dual OCU DP may interoperate over the carrier system with another OCU DP, DS0
DP, DS0 cross-connect system or switch, and may be located in an end office, hub
office, intermediate office or remote digital terminal system.
Figure 16. Dual OCU DP
The Dual OCU DP incorporates these features:
• Dual independent OCU DPs on a single card
• Loop Quality Monitor and A/B signaling options
• Remotely provisionable, Performance Monitoring via Digital System-6.
Faceplate LED indicators include:
• STATUS (1 and 2)
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 30 of 32
1.5.11 Dual DS0 DP
The Dual Digital Signal Zero Dataport (DS0 DP) is a Total Access 1500 channel unit
(see Figure 17.) Is a channel that is used in the Dataphone Digital Service (DDS) to
interface the basic DDS DS0 (64 kbps) signal to a T-carrier line. The DS0 DP is
generally located in either a hub or intermediate office. It is used in conjunction with
an ADTRAN All-Rate Office Channel Unit (OCU) dataport or Total Reach DDS
dataport located at the end office to extend the DDS network to an end office that had
exclusively served voice channels.
Figure 17. Dual DS0 DP
The Dual DS0 DP incorporates these features:
• Dual independent DS0 DPs on a single card
• Subrate, 19.2, 56, and 64 kbps Clear Channel operation; Subrate Error Correction,
Zero Code Suppression, and Latching Loopback
• The dataport can be optioned to operate as a DS0 DP or as a Clear Channel Unit
(CCU).
• Switched 56 Tandem functionality
• Performance Monitoring via Digital System-6.
Faceplate LED indicators include:
• STATUS (1 and 2)
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 31 of 32
1.6
Bay Configurations
Total Access 1500 is available in a 7-foot bay configuration. The actual number of
services that can be provisioned from a particular bay depends on the type and
concentration of those services. See Figure 18 for an example of a 14-shelf
installation.
2" Fuse Panel
TA3000
Total Access 3000 Shelf is
6 inches in height
Heat Baffle #7
TA1500 #14
TA1500 #13
Heat Baffle #6
TA1500 #12
Total Access 1500 Shelf is
3.5 inches in height
TA1500 #11
Heat Baffle #5
TA1500 #10
TA1500 #9
Heat Baffle #4
Heat Baffle is 1.75 inches
in height
TA1500 #8
TA1500 #7
Heat Baffle #3
TA1500 #6
TA1500 #5
Heat Baffle #2
TA1500 #4
TA1500 #3
Heat Baffle #1
TA1500 #2
TA1500 #1
Seven-Foot Bay
Figure 18. Bay Configuration
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
System Description
Page 32 of 32
This page intentionally left blank.
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
Engineering Guidelines
Page 1 of 16
Total AccessTM 1500 Engineering Guidelines
This section of ADTRAN’s Total Access 1500 System Manual is designed for use by
network engineers, planners, and designers who are upgrading or intensifying a
communications network. It contains general information and describes physical and
operational concepts, card functions, network relationship, provisioning, testing, alarm
status, and system monitoring.
Contents
2.1
2.2
2.3
2.4
Dimensions and Weight of Equipment ................................................................................ 2
System Power Requirements ................................................................................................ 4
Heat Considerations .............................................................................................................. 6
Alarm Interfaces ..................................................................................................................... 8
2.4.1 Alarm Input and Outputs ............................................................................................................... 8
2.5 Network Timing .................................................................................................................... 10
2.5.1 64 KHz Composite Clock ............................................................................................................ 10
2.5.2 External Clock ............................................................................................................................. 11
2.5.3 Clock Termination ....................................................................................................................... 12
2.6 Network Connections .......................................................................................................... 12
2.7 Local Loop Connections ..................................................................................................... 12
Figures
Figure 1.
Figure 2.
Figure 3.
Figure 4.
Figure 5.
Figure 6.
Alarm Input Pin Assignments (P14) ................................................................................ 8
Alarm Output Pin Assignments (P13).............................................................................. 9
Daisy-Chain Office Timing Connections ....................................................................... 10
External Clock Timing Connections .............................................................................. 11
Backplane Layout of AMP Champ Connections ..................................................... 13, 14
Local Loop Corrector Pin Assignment (P1-P4) ............................................................. 15
Tables
Table 1. Total Access 1500 Equipment Dimensions and Weights .................................................. 3
Table 2. -48V Current Draw Worksheet ......................................................................................... 5
Table 3. Heat Dissipation Worksheet ............................................................................................. 7
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
Engineering Guidelines
Page 2 of 16
Total AccessTM 1500 Engineering Guidelines
2.1
Dimensions and Weight of Equipment
Table 1 lists the dimensions and weight of the Total Access 1500 chassis, heat baffle,
commons, and several access modules.
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
Engineering Guidelines
Page 3 of 16
Table 1. Total Access 1500 Equipment Dimensions and Weights
Equipment Specifications
Part Number
H x W x D (in)
Weight (lb)
Main Chassis
1180001L1
3.52 x 23.00 x 10.75
12.0
Heat Baffle
1180002L1
1.75 x 23.00 x 9.95
1.2
PSU/RGU Internal Ring Generator
1180007L1
2.81 x 1.09 x 9.75
0.71
PSU/RGU External Ring Generator
1180007L2
2.81 x 1.09 x 9.75
0.64
SCU
1180008L1
2.81 x 1.54 x 9.75
0.72
SCU (COT) w/MLT
1180008L2
2.81 x 1.54 x 9.75
0.84
SCU (RT) w/MLT
1180008L3
2.81 x 1.54 x 9.75
0.66
Dual LIU
1180009L1
2.81 x 1.14 x 9.75
0.55
Quad LIU
1180109L1
2.81 x 1.14 x 9.75
0.60
DS0 DP
1180003L1
2.81 x 0.62 x 9.75
0.21
OCU DP
1180005L1
2.81 x 0.62 x 9.75
0.31
U-BR1TE
1180020L1
2.81 x 0.62 x 9.75
0.25
E&M/TO
1180402L1
2.81 x 0.62 x 9.75
0.27
E&M/TO w/SMAS
1180402L2
2.81 x 0.62 x 9.75
0.32
FXS/DPO
1180403L1
2.81 x 0.62 x 9.75
0.21
FXO/DPT
1180404L1
2.81 x 0.62 x 9.75
0.21
Dual DS0 DP
1180203L2
2.81 x 0.62 x 9.75
0.32
Dual DS0 DP w/SMAS
1180203L1
2.81 x 0.62 x 9.75
0.33
Dual OCU DP
1180205L2
2.81 x 0.62 x 9.75
0.38
Dual OCU DP w/SMAS
1180205L1
2.81 x 0.62 x 9.75
0.41
Dual FXO
1180207L2
2.81 x 0.62 x 9.75
0.20
Dual FXO w/SMAS
1180207L1
2.81 x 0.62 x 9.75
0.25
Dual FXS
1180208L2
2.81 x 0.62 x 9.75
0.23
Dual FXS w/SMAS
1180208L1
2.81 x 0.62 x 9.75
0.24
Quad FXO
1175407L1
2.81 x 0.62 x 9.75
0.27
Quad FXO w/MLT
1175407L2
2.81 x 0.62 x 9.75
0.30
Quad FXS w/MLT
1180408L1
2.81 x 0.62 x 9.75
0.35
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
Engineering Guidelines
Page 4 of 16
2.2
System Power Requirements
In the Total Access 1500, power is supplied to the commons and access cards from the
PSU/RGU. The PSU/RGU converts -48V battery voltage to the various other voltages
required by the commons and access cards. Additionally, unfiltered -48V is also
routed to all commons and access cards in the chassis. Table 2 lists the current draw
of each module at -48V, taking into consideration the inefficiency of the PSU/RGU
and the amount of on-board current needed from the -48V unfiltered line. Power
dissipated outside the channel bank, such as loop power, is not included. Use Table 2
as a worksheet to calculate the total current draw for a single shelf deployment.
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
Engineering Guidelines
Page 5 of 16
Table 2. -48V Current Draw Worksheet
ADTRAN P/N
Description
-48V Current (A)
1180007L1
PSU/RGU int RG
0.808
x
=
A
1180007L2
PSU/RGU ext RG
0.016
x
=
A
1180008L1
SCU
0.088
x
=
A
1180008L2
SCU (COT) w/MLT
0.088
x
=
A
1180008L3
SCU (RT) w/MLT
0.088
x
=
A
1180009L1
Dual LIU (master)
0.042
x
=
A
1180009L1
Dual LIU (slave)
0.025
x
=
A
1180109L1
Quad LIU (master)
0.129
x
=
A
1180109L1
Quad LIU (slave)
0.073
x
=
A
1180003L1
DSO DP
0.013
x
=
A
1180005L1
OCU DP
0.021
x
=
A
1180020L1
UBR1TE
0.023
x
=
A
1180402L1
E&M/TO
0.062
x
=
A
1180402L2
E&M/TO w/SMAS
0.062
x
=
A
1180403L1
FXS/DPO
0.038
x
=
A
1180404L1
FXO/DPT
0.007
x
=
A
1180203L2
Dual DS0 DP
0.026
x
=
A
1180203L1
Dual DS0 DP w/SMAS
0.026
x
=
A
1180205L2
Dual OCU DP
0.042
x
=
A
1180205L1
Dual OCU DP w/SMAS
0.042
x
=
A
1180207L2
Dual FXO/DPT
0.006
x
=
A
1180207L1
Dual FXO/DPT w/SMAS
0.006
x
=
A
1180208L2
Dual FXS/DPO
0.065
x
=
A
1180208L1
Dual FXS/DPO w/SMAS
0.065
x
=
A
1175407L1
Quad FXO
0.015
x
=
A
1175407L2
Quad FXO w/MLT
0.015
x
=
A
1180408L1
Quad R-POTS*
0.074
x
=
A
* Assumes 2 of 4 circuits off hook
Total AccessTM 1500 System Manual
Quantity
Total
A
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
Engineering Guidelines
Page 6 of 16
2.3
Heat Considerations
Table 3 lists the heat dissipation of each module. Use this table as a worksheet to
calculate total heat dissipation associated with Total Access 1500 modules.
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
Engineering Guidelines
Page 7 of 16
Table 3. Heat Dissipation Worksheet
ADTRAN P/N
Description
Heat Dissipation
(watt)
1180007L1
PSU/RGU int RG
3.16
x
=
W
1180007L2
PSU/RGU ext RG
0.76
x
=
W
1180008L1
SCU
4.24
x
=
W
1180008L2
SCU (COT) w/MLT
4.24
x
=
W
1180008L3
SCU (RT) w/MLT
4.24
x
=
W
1180009L1
Dual LIU (master)
2.02
x
=
W
1180009L1
Dual LIU (slave)
1.21
x
=
W
1180109L1
Quad LIU (master)
6.21
x
=
W
1180109L1
Quad LIU (slave)
3.52
x
=
W
1180003L1
DSO DP
0.63
x
=
W
1180005L1
OCU DP
1.00
x
=
W
1180020L1
UBR1TE
1.10
x
=
W
1180402L1
E&M/TO
1.99
x
=
W
1180402L2
E&M/TO w/SMAS
1.99
x
=
W
1180403L1
FXS/DPO
1.81
x
=
W
1180404L1
FXO/DPT
0.58
x
=
W
1180203L2
Dual DS0 DP
1.26
x
=
W
1180203L1
Dual DS0 DP w/SMAS
1.26
x
=
W
1180205L2
Dual OCU DP
2.01
x
=
W
1180205L1
Dual OCU DP w/SMAS
2.01
x
=
W
1180207L2
Dual FXO/DPT
0.79
x
=
W
1180207L1
Dual FXO/DPT w/SMAS
0.79
x
=
W
1180208L2
Dual FXS/DPO
2.44
x
=
W
1180208L1
Dual FXS/DPO w/SMAS
2.44
x
=
W
1175407L1
Quad FXO
1.84
x
=
W
1175407L2
Quad FXO w/MLT
1.84
x
=
W
1180408L1
Quad R-POTS*
2.40
x
=
W
Total
W
* Assumes 2 of 4 circuits off hook
Total AccessTM 1500 System Manual
Quantity
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
Engineering Guidelines
Page 8 of 16
2.4
Alarm Interfaces
2.4.1
Alarm Inputs and Outputs
For alarms, the physical wiring will depend on which type of alarm equipment is used.
ADTRAN recommends referring to the Alarm Equipment manufacturer’s instructions
for alarm wiring.
Inputs
Four alarm inputs are supported and are accessible at backplane wirewrap header P14.
They are ACO, Remote, AUX1, and AUX2. The active alarm state is -48 V or contact
closure. Figure 1 lists the backplane pin assignments for the alarm inputs.
P14
1
17
+
–
CLK IN
+
–
CLK OUT
+
–
LOCCK
A
B
ACO
A
B
RMT
A
B
AUX1
A
B
AUX2
Figure 1. Alarm Input Pin Assignments (P14)
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
Engineering Guidelines
Page 9 of 16
Outputs
The shelf currently supports six alarm outputs accessible at backplane wirewrap header
P13. Alarming is dependent on how the TA 1500 system is configured. When the TA
1500 is configured as a channel bank using a single or dual T1 feed, the alarm outputs
should be represented by VMJ (Visual Major), VMN(Visual Minor), AudMJ (Audible
Major), AudMN (Audible Minor), AUX (Auxiliary) and -48. However, if the TA
1500 bank is configured as a DLC using quad T1 feed, the alarm outputs should be
represented by AMJ (A Digroup Major), BMJ(B Digroup Major), CMJ (C Digroup
Major), DMJ (D Digroup Major), BANKMJ(Bank Digroup Major), and -48. In the
DLC mode, the TA 1500 separately monitors the performance of each digroup (A, B,
C and D) and the bank. The DLC mode assures that an alarm at the digroup level
provides appropriate central office and remote information. With the exception of
-48ALM, each alarm supports normally open or normally closed relay contacts. The 48ALM is an indication that the -48 V input fuse on the PSU/RGU has been tripped
and is at a -48 V level when asserted. Refer to Figure 2 for alarm output connector
pin assignments.
P13
1
17
NO COM NC
NO COM NC
NO COM NC
NO COM NC
VMJ/AMJ
VMN/BMJ
AudMJ/ CMJ
AudMN/DMJ
NO COM NC
-48
AUX/BANKMJ ALM
Figure 2. Alarm Output Pin Assignments (P13)
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
Engineering Guidelines
Page 10 of 16
2.5
Network Timing
2.5.1
64 KHz Composite Clock
Office timing inputs are provided by backplane wirewrap connector P14, labeled CLK
IN +,-. Connector P14 also provides daisy-chaining of up to 14 additional TA1500
dual-LIU systems or 28 single-LIU systems from the same composite clock using the
terminals labeled CLK OUT +, -. Figure 3 illustrates the composite clock wiring
scheme for multiple shelves.
From
BITS
+
CLK OUT
—
SW1
+
—
In
CLK IN
+
CLK OUT
—
Out
SW1
+
—
CLK IN
+
CLK OUT
—
Out
SW1
+
—
CLK IN
Unused on last link
Figure 3. Daisy-Chain Office Timing Connections
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
Engineering Guidelines
Page 11 of 16
2.5.2
External Clock
Because some applications may require the shelf to provide source timing, an
additional connection is provided at P14 labeled LOCCK +,- to provide a 64 kHz
composite clock output. This output clock can be used as a timing source for up to 14LIU systems or 28-LIU systems. Figure 4 illustrates the external clock wiring
scheme.
From
LOCCK
+
CLK OUT
—
SW1
+
—
In
CLK IN
+
CLK OUT
—
Out
SW1
+
—
CLK IN
+
CLK OUT
—
Out
SW1
+
—
CLK IN
Unused on last link
Figure 4. External Clock Timing Connections
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
Engineering Guidelines
Page 12 of 16
2.5.3
Clock Termination
Clock termination switch SW1 should be set to the IN position on a single shelf
installation. In a daisy-chain arrangement, SW1 should be set to the OUT position on
all shelves, except the first in the chain where SW1 should be set to the IN position.
2.6
Network Connections
Total Access 1500 supports either DS1 or DSX-1 network connections. The copper
pair network interface connects to the backplane at wirewrap connector P11. Refer to
Total Access 1500 Turn-Up Guide 61180001L1 TU-22 for connector pin assignments.
2.7
Local Loop Connections
Local loop connections in the form of copper pairs are delivered through four 50-pin
AMP Champ connectors on the backplane. Each of the 24 channel unit slots in the
chassis has access to four copper pairs. Pair 1 (T/R) is assigned to connector P1, Pair 2
(T1/R1) to P2, Pair 3 (E/SG) to P3, and Pair 4 (M/SB) to P4. See Figure 5 for the
layout of backplane AMP Champ connectors. Figure 6 illustrates the pin assignment
of connectors P1-P4.
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
20
40
25
21
SW1
P1
P1
40
30
20
10
1
+
–
C2
+
40
30
25
50
+
20
10
1
–
LOCCK
–
T/R
J21
CLK IN
21
1
40
30
21
PAIR 1
20
10
1
40
30
21
B
ACO
A
20
–
40
30
21
B
RMT
A
10
1
40
30
21
CLK OUT
+
J20
CLK OUT
C1
TERM
OUT
PAIR 1
20
40
20
50
10
30
1
B
1
26
AUX1
A
B
40
30
T/R
20
10
1
LOCCK
+
20
10
J18
40
30
21
B
40
30
21
ACO
A
20
10
1
J17
20
10
1
VMN
B
1
26
J15
20
10
1
20
10
T1 / R1
40
30
B
40
30
21
17
P14
P14
AUX2
A
40
30
PAIR 2
AUX1
A
25
50
20
10
AUX
20
10
1
20
10
40
30
21
NO COM NC
AMN
1
NO COM NC
21
AMJ
1
NO COM NC
40
30
21
-48
1
26
20
10
1
ALM
17
40
30
21
J12
P2
P2
20
10
1
40
30
21
P12
EN
20
10
25
50
40
30
21
RS485
1
SW2
40
30
25
50
40
30
21
PAIR 2
20
10
1
J8
1
26
20
10
1
20
10
1
T1 / R1
40
30
21
20
10
1
40
30
21
AUX
40
30
21
AMN
20
10
1
AMJ
40
30
21
NO COM NC
E / SG
20
10
1
J7
NO COM NC
40
30
21
J6
NO COM NC
PAIR 3
20
10
1
J34
MGMT
1
26
20
10
1
ALM
-48
40
30
21
40
30
40
30
21
T
1
17
1
21
20
10
1
R
P4
20
10
1
20
10
1
T1 R1
A
P11
5
40
30
T
1
21
R
40
30
5
40
30
21
P12
PAIR 4
20
10
1
T1 R1
B
P10
21
25
50
J3
DIS
VMN
P3
40
30
21
VMJ
J11
NO COM NC
20
10
1
A
B
RS485
J10
NO COM NC
21
1
P13
P13
20
10
1
T
1
20
10
1
40
5
P3
P3
40
30
21
M / SB
A
B
RS485
20
30
21
10
T1 R1
C
1
P9
R
J1
R
20
10
1
EN
T
1
1
5
20
T1 R1
P
1
26
20
10
25
50
40
30
21
30
SW2
DIS
40
20
10
1
P7
R
J31
1
T
RS485
1
40
T1 R1
D
P8
Figure 5. Backplane Layout of AMP Champ Connectors
40
30
21
B
40
30
21
NO COM NC
VMJ
1
NO COM NC
21
1
J2
P13
RMT
A
P2
20
10
1
21
P14
17
21
–
AUX2
A
1
J16
–
J13
+
J5
CLK IN
J22
10
C2
SW1
IN
CLK
10
1
40
20
P1
30
R1
10
30
21
40
J24
J24
C1
J23
30
J23
R1
J19
J21
21
J22
J4
J12
1
J20
10
OUT
J19
J14
J18
1
J16
J32
30
TERM
J17
J9
J15
21
SW1
J11
E
D
C
B
A
PAIR 3
5
J30
20
10
1
20
10
1
J33
J29
20
10
E
D
C
B
40
30
21
P5
E
D
C
B
A
21
J14
O
N
J13
20
10
1
E / SG
24
RN1
RN2
J8
IN
J10
Total AccessTM 1500 System Manual
J9
T
R
P6
I
24
20
10
25
50
40
30
21
30
TB
PGTC
1
J28
B Y PA S S
E
D
C
B
A
40
IN
J27
20
10
1
20
10
CLK
J7
RTN
1
26
30
21
40
IN
R
T
N
I
N
40
-48 SEC
3 TB2
SMAS
MLT
-48 SEC
10
20
10
1
20
RTN
J26
30
1
J6
D2
1
26
40
30
21
D1
40
21
J34
MGMT
5
J25
1
20
20
10
1
30
O
N
10
O
N
O
N
J5
21
61180001L1-1A
TOTAL ACCESSTM 1500
Engineering Guidelines
Page 13 of 16
2001, ADTRAN, Inc.
40
30
10
20
21
1
20
40
1
10
J24
30
21
21
J23
P12
P1
40
30
P3
P3
40
30
10
20
21
1
A
B
RS485
25
20
T/R
40
1
10
J21
30
21
EN
20
PAIR 1
40
50
20
1
10
21
30
C2
C1
10
1
J22
20
10
1
25
50
40
30
21
RS485
SW2
20
40
DIS
10
1
PAIR 3
20
10
1
40
30
21
B
RMT
A
30
21
B
ACO
A
B
1
26
AUX1
A
J19
–
B
40
30
21
20
10
1
AUX2
A
40
30
21
J18
40
30
21
J17
40
30
21
P2
20
10
1
40
30
20
10
1
25
50
40
30
21
40
1
26
30
21
PAIR 2
20
10
1
VMN
VMJ
21
NO COM NC
NO COM NC
20
10
20
10
1
T1 / R1
40
30
21
40
30
21
20
10
1
J34
MGMT
40
30
21
AUX
AMN
AMJ
1
NO COM NC
NO COM NC
NO COM NC
-48
20
10
1
1
26
20
10
1
ALM
1
40
30
21
J12
40
30
21
T
1
17
40
30
21
J11
20
10
1
T1 R1
A
P4
P4
R
P11
P11
20
10
1
P12
5
20
10
1
40
30
21
40
30
21
T
1
P3
A
B
RS485
25
50
40
25
50
30
SW2
DIS
PAIR 3
PAIR 4
20
10
1
T1 R1
B
P10
20
10
21
RS485
1
R
EN
40
30
21
5
20
10
1
T
1
40
30
21
J8
20
M / SB
40
30
21
1
10
T1 R1
C
P9
40
30
21
J7
R
E / SG
20
10
1
5
20
10
1
10
1
R
J6
20
1
26
T
1
40
30
21
40
30
21
40
T1 R1
D
P8
20
10
1
J34
MGMT
1
5
20
10
1
20
1
R
R
P4
1
26
5
40
30
21
T
1
30
40
20
10
1
T1 R1
P
P7
20
10
1
T1 R1
A
P11
J31
T
1
40
30
21
T
1
R
25
50
5
5
40
30
21
20
10
1
PAIR 4
20
10
1
T1 R1
B
P10
T
1
J29
20
10
40
M / SB
J33
20
30
21
1
10
T1 R1
C
P9
R
5
P5
T
1
24
J1
20
10
1
R
40
T1 R1
D
P8
1
5
20
1
R
J31
T
1
26
30
T
5
R
P6
I
20
10
1
25
50
J33
J29
20
10
24
20
10
24
30
TB
P5
PGTC
1
J28
B Y PA S S
40
20
10
1
T1 R1
P
P7
40
Figure 5. Backplane Layout of AMP Champ Connectors (Continued)
E / SG
20
10
1
20
10
1
1
J9
P13
21
P14
17
J8
+
J16
LOCCK
J7
R1
J11
J15
J6
–
J14
+
J10
J20
J9
J13
CLK OUT
J5
–
J4
J10
J3
10
+
J1
21
CLK IN
J2
J3
J30
E
D
C
B
A
E
D
C
B
E
D
C
B
A
J32
30
RN1
RN2
R
P6
20
I
24
20
10
40
20
R
T
N
I
N
RTN
40
IN
20
R
T
N
I
N
40
-48 SEC
3 TB2
SMAS
MLT
-48 SEC
-48 SEC
3 TB2
SMAS
MLT
-48 SEC
25
50
30
TB
PGTC
1
J28
B Y PA S S
T
E
D
C
B
A
RTN
IN
J27
10
1
J32
30
IN
20
RTN
J26
1
26
30
OUT
10
TERM
10
D2
D2
1
26
5
5
21
40
J25
30
20
1
40
21
SW1
D1
D1
IN
21
J5
10
J4
E
D
C
B
A
21
J2
E
D
C
B
E
D
C
B
A
J30
E
D
C
B
A
RN1
RN2
IN
J27
10
RTN
J26
30
10
J25
2001, ADTRAN, Inc.
30
O
N
O
N
20
1
10
O
N
CLK
61180001L1-1A
TOTAL ACCESSTM 1500
Engineering Guidelines
Page 14 of 16
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
Engineering Guidelines
Page 15 of 16
25
50
24
49
23
48
22
47
21
46
20
45
19
44
18
43
17
42
16
41
15
40
14
39
13
38
12
37
11
36
10
35
9
34
8
33
7
32
6
31
5
30
4
29
3
28
2
27
1
26
NC
NC
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
Circuit 24
Circuit 23
Circuit 22
Circuit 21
Circuit 20
Circuit 19
Circuit 18
Circuit 17
Circuit 16
Circuit 15
Circuit 14
Circuit 13
Circuit 12
Circuit 11
Circuit 10
Circuit 9
Circuit 8
Circuit 7
Circuit 6
Circuit 5
Circuit 4
Circuit 3
Circuit 2
Circuit 1
50 PIN
AMP
RECEPTACLE
Figure 6. Local Loop Connector Pin Assignment (P1-P4)
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
Engineering Guidelines
Page 16 of 16
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
Application Guideline
Page 1 of 12
Total AccessTM 1500 Application Guide
This section of ADTRAN’s Total Access 1500 System Manual is designed for use by
network engineers, planners, and designers who are upgrading or intensifying a
communications network. It contains general information and describes physical and
operational concepts, network relationships, and system monitoring.
CONTENTS
3.1 Overview .................................................................................................................................. 3
3.1.1
Total Access 1500 Features Summary ......................................................................................... 4
3.2 D4 Replacement Application ................................................................................................. 5
3.2.1
Special Services Deployment (TDM Channel Bank Applications) ............................................... 5
3.3 SLC-96 Replacement Applications ....................................................................................... 9
3.3.1
Total Access 1500 Solves Today’s DLC Problems ....................................................................... 9
FIGURES
Figure 1.
Figure 2.
Figure 3.
Figure 4.
Figure 5.
COT D4 Replacement ................................................................................................................. 5
RT D4 Replacement .................................................................................................................... 6
D4 Local Loop Connector Pin Assignment ................................................................................ 7
COT SLC-96 Replacement ....................................................................................................... 10
SLC-96 Local Loop Connector Pin Assignment ................................................................ 11, 12
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
Application Guideline
Page 2 of 12
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
Application Guideline
Page 3 of 12
Total AccessTM 1500 Application Guideline
3.1
Overview
The Total Access 1500 (TA 1500) channel bank can be used as a replacement for
existing D4 channel banks to recover valuable floor space, or as an alternative to
standard D4 channel banks for new installations. In addition to D4 channel banks, the
TA 1500 can operate in accordance with TR-08 for SLC-96 alternatives.
The Total Access 1500 is an Integrated Multi-service Access Platform for deploying
narrow band services from TDM infrastructures. A small, extremely versatile
platform, TA 1500 integrates the functionality of many carrier products into a single
high-density chassis. TA 1500’s small footprint (2U high mounting) makes it the
perfect choice for integrated communications providers, such as ILECs, CLECs, and
ISPs, who need to deploy services from crowded Remote Terminals (RT), Central
Offices (C.O.), or Co-Location (COLO) facilities.
The TA 1500 provides a variety of services, including Plain Old Telephone Service
(POTS), Special Services including ISDN, DDS, FXO, FXS, E&M, DPO, DPT, and
PLAR. The TA 1500 complements ADTRAN’s broadband Multi-service Access
Platform, TA 3000, which can terminate and distribute higher bandwidth services such
as SONET, DS3, HDSL, T1, and Optical DS2. The TA 1500 can be deployed as a:
•
•
•
Small Digital Loop Carrier (DLC), for a simple and effective means of
deploying POTS (up to 96 lines in 2U mounting)
Special services delivery platform, with up to three times the density of any
competing D4 platform
Hi-Density Integrated Access Device, serving up to 96 voice and data
customers using four T1 network interface.
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
Application Guideline
Page 4 of 12
The TA 1500 is a modular device, with five common slots and 24 access slots.
Common units required for operation are a Power Supply Unit (PSU), Line Interface
Unit (LIU), and System Controller Unit (SCU). A second, redundant PSU and LIU
may be deployed for added reliability. The PSU is available with an integrated Ring
Generator providing up to 20 REN ringing capacity. The LIU can support up to four
T1 interfaces and has the full Time Slot Assignment (TSA) capability. This feature
allows users to “steer” varied amounts of bandwidth from the network to any of the
access slots, ensuring no bandwidth is stranded. Additional LIUs will provide HDSL2
and Fiber interfaces. The 24 access slots accept a variety of voice and data access
modules allowing users to optimize their service offering for each application.
The TA 1500 is designed for 23-inch relay racks. Full compliance with NEBS Level 3
and UL 1950 ensure maximum reliability and safety.
3.1.1
TA 1500 Features Summary
•
•
•
•
•
•
•
•
•
POTS, DS0-Specials, and xDSL
Up to 96 2-wire interfaces
Extremely Small (2U) mounting for crowded CO or RT mountings
Fully redundant commons and APS to ensure service reliability
TR-08 signaling for direct connection to switch equipment
Three times as dense as a D4 channel bank when used for specials
Integrated Digital and Metallic Test Access
Mechanized Loop Testing (MLT)
Connects to Switched Maintenance Access System (SMAS)
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
Application Guideline
Page 5 of 12
3.2
D4 Replacement Application
3.2.1
Special Services Deployment (TDM Channel Bank Applications)
If special services are the main concern, the TA 1500 can be deployed in the Central
Office or Remote Terminal to provide the same functionality as a legacy D4 channel
bank. In the central office environment, the small size of the unit provides almost
three times the density of a standard D4 in rack configurations.
When replacing existing D4 channel banks, the TA 1500 operates in a single T1
mode. In the single T1 mode, the system maintains standard D4 cabling
guidelines to facilitate the replacement process. The TA 1500 is designed for
extended temperature environments so it can be installed in both COs and RTs.
Refer to Figure 1 and Figure 2.
to alarm system
(opt)
to composite
clock source
P13
P14
P11
T/R
DACS
or switch
P1
DS1 or DSX-1
to cross connect
TA1500
TB1
Primary Feed
to battery
source
Redundant Feed (opt)
Figure 1. COT D4 Replacement
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
Application Guideline
Page 6 of 12
to alarm system
(opt)
F
D rom
SX
-1 DS
So 1 o
ur r
ce
P13
DS1 or DSX-1
P11
P1-P4
T/R
to cross
connect
TA1500
TB1
to battery
source
TB2
Primary Feed
Redundant Feed (opt)
to ringing
source
(required when
using 1180007L2)
Figure 2. RT D4 Replacement
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
Application Guideline
Page 7 of 12
Wiring is identical to existing D4 channel banks. Pinout definitions are shown
below in Figure 3.
P1
48
22
47
21
46
20
45
19
44
18
43
17
42
16
41
15
40
14
39
13
38
12
37
11
36
10
35
9
34
8
33
7
32
6
31
5
30
4
29
3
28
2
27
1
26
1
Circuit 23
5
Circuit 22
Circuit 21
-48 PRI
Circuit 20
-48 SEC
Frame
Ground
23
TB1
Circuit 24
RTN
49
IN
24
NC
NC
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
RTN
50
IN
25
TB1
Circuit 19
Circuit 18
Circuit 17
3 TB2
Circuit 16
Circuit 15
20HZ
Circuit 14
Circuit 13
RTN
Circuit 12
Circuit 11
Circuit 10
Frame Ground
Circuit 9
Circuit 8
1
Circuit 7
TB2
Circuit 6
Circuit 5
Circuit 4
1
Circuit 3
P11
5
Circuit 2
T
Circuit 1
50 PIN
AMP
RECEPTACLE
R
T1 R1
A
P11
P13
1
P13
17
NO COM NC
NO COM NC
NO COM NC
NO COM NC
VMJ/AMJ
VMN/BMJ
AudMJ/ CMJ
AudMN/DMJ
NO COM NC
-48
AUX/BANKMJ ALM
P14
1
17
P14
+
–
CLK IN
+
–
CLK OUT
+
–
LOCCK
A
B
ACO
A
B
RMT
A
B
AUX1
A
B
AUX2
Figure 3. D4 Local Loop Connector Pin Assignment
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
Application Guideline
Page 8 of 12
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
Application Guideline
Page 9 of 12
3.3
SLC-96 Replacement Applications
3.3.1
TA 1500 Solves Today’s DLC Problems
Remote Terminals, which house Digital Loop Carriers (DLC), are fast becoming
exhausted of their capacity as customers continue to order additional phone lines for
the Internet, etc. In addition, many special services, such as ISDN and DDS, must be
deployed out of DLCs, further decreasing POTS capacity, while wasting valuable
copper pairs connected to the cross box. Couple this with the imminent mass
deployment of xDSL services out of RT cabinets, and the Service Providers have a
serious challenge on their hands. Do they pour more concrete and install yet another
costly DLC cabinet, try to retrofit the cabinet for new services, or try to get more life
out of the system by better allocating RT resources?
The TA 1500 Multi-services Platform solves this problem. Since the shelf is only 3.5
inches high it can mount in almost any existing RT cabinet. The bank can be placed
inside the RT to augment current services (POTS) and special services. The LIU used
for POTS & Specials (LIU 4T1+P) terminates five individual T1s – four working T1s
and one T1 for protection (same as SLC-96).
If only additional POTS lines are needed at the RT, the TA 1500 is directly connected
to the switch using TR-008 or using another TA 1500 as a Central Office Terminal
(COT). A COT must be used if special services are deployed. This application
requires the LIU 4T1+P and is for TDM backbone infrastructures.
For SLC-96 replacement, the TA 1500 terminates five T1 signals. Both Mode I and
Mode III are supported. Refer to Figure 4.
Loop wiring is defined in Figure 5.
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
Application Guideline
Page 10 of 12
Universal Configuration
COT
to MDF
to battery
feed
P1-P4
RT
T1's
P7-P11
P7-P11
primary feed
redundant feed
to customer
MDF
P1-P4
primary feed
TB1
TA1500
TA1500
TB1
redundant feed
to ringing
source
(required when
using 1180007L2)
TB2
to alarm
system
P13
to composite
clock source
P14
P5
P6
to alarm
system
P13
P6
to battery
feed
dc-bypass
pair
to PGTC
or other
test system
to other
COT sharing
test pair
to other
RT sharing
test pair
Integrated Configuration
RT
T1's
P7-P11
to customer
MDF
P1-P4
primary feed
local
switch
TA1500
T
B
C
U
P6
TB1
redundant feed
to battery
feed
TB2
to ringing
source
P13
to alarm
system
P14
to composite
clock source
dc-bypass
pair
Figure 4. COT SLC-96 Replacement
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
61180001L1-1A
TOTAL ACCESSTM 1500
Application Guideline
Page 11 of 12
25
50
24
49
23
48
22
47
21
46
20
45
19
44
18
43
17
42
16
41
15
40
14
39
13
38
12
37
11
36
10
35
9
34
8
33
7
32
6
31
5
30
4
29
3
28
2
27
1
26
NC
NC
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
T
R
50 PIN
AMP
RECEPTACLE
P1, P2, P3, P4
25
50
Circuit 24
24
49
Circuit 23
23
48
Circuit 22
22
47
Circuit 21
21
46
Circuit 20
20
45
Circuit 19
19
44
Circuit 18
18
43
Circuit 17
17
42
Circuit 16
16
41
Circuit 15
15
40
Circuit 14
14
39
Circuit 13
13
38
Circuit 12
12
37
Circuit 11
11
36
Circuit 10
10
35
Circuit 9
9
34
Circuit 8
8
33
Circuit 7
7
32
Circuit 6
6
31
Circuit 5
5
30
Circuit 4
4
29
Circuit 3
3
28
Circuit 2
2
27
Circuit 1
1
26
NC
NC
NC
NC
NC
NC
SEIZE
SEZBY
NC
NC
NC
NC
NC
NC
NC
NC
TSTALM
TMAJ
SMAS TD
SMAS RD
SMAS TC
SMAS RC
SMAS TB
SMAS RB
SMAS TA
SMAS RA
LOCK C
LOCK D
LOCK A
LOCK B
PROC C
PROC D
PROC A
PROC B
OH C
OH D
OH A
OH B
SLV C
SLV D
SLV A
SLV B
MLT TD
MLT RD
MLT TC
MLT RC
MLT TB
MLT RB
MLT TA
MLT RA
50 PIN
AMP
RECEPTACLE
P5
Figure 5. SLC-96 Local Loop Connector Pin Assignment
Total AccessTM 1500 System Manual
2001, ADTRAN, Inc.
61180001L1-1A
TOTAL ACCESSTM 1500
Application Guideline
Page 12 of 12
P6
P6
1
4
T
R
1
P7 - P11
T
I
P11
R
5
1
T1 R1
A
P10
T
R
5
T1 R1
B
1
T
P9
R
5
1
T1 R1
C
T
P8
R
5
1
T1 R1
D
P7
T
R
5
T1 R1
P
P13
1
P13
17
NO COM NC
NO COM NC
NO COM NC
NO COM NC
VMJ/AMJ
VMN/BMJ
AudMJ/ CMJ
AudMN/DMJ
NO COM NC
-48
AUX/BANKMJ ALM
P14
1
17
P14
+
–
+
CLK IN
–
CLK OUT
+
A
–
LOCCK
B
A
ACO
B
RMT
A
B
AUX1
A
B
AUX2
TB1
1
Frame
Ground
-48 SEC
RTN
-48 PRI
IN
RTN
5
IN
TB1
3 TB2
20HZ
RTN
TB2
Frame Ground
1
Figure 5. SLC-96 Local Loop Connector Pin Assignment (Continued)
2001, ADTRAN, Inc.
Total AccessTM 1500 System Manual
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project