ADTRAN | Total Access 1500 | Job Aid | Adtran Total Access 1500 Job Aid

Adtran Total Access 1500 Job Aid
Total Access 1500 Quad R-POTS
Total Access 1500
Quad
R-POTS
P/N: 1180408L1
CLEI: VALIUW0F_ _
R-POTS
1180408L1
BUSY
DESCRIPTION
The ADTRAN® Total Access® 1500 Quad R-POTS is a Remote Terminal POTS
access module that provides four independent POTS interfaces between a Total Access
1500 Pulse Code Modulation (PCM) backplane and a 2-wire Voice Frequency (VF)
transmission and signaling facility. Each interface contains the necessary circuitry to
convert voice data signals from the customer loop to PCM digital data and convert
PCM digital data from the carrier to voice data. The access module also provides
ringing voltage to the loop when appropriate. The Quad R-POTS features are as
follows:
♦ Four independent VF interfaces
♦ FXS, TR08, PLAR, Tandem, DPO, and TO with SC operating modes
♦ Loop start, Ground start, and Wink start signaling modes
♦ Caller ID Class™ compatible
♦ Digital loopback to network
61180408L1-22D
0412
ports 1-4 use P1-P4 (T/R), respectively. In the 19-inch chassis, physical slots 1-6 use
P1, slots 7-12 use P2, and slots 13-18 use P3.
PROVISIONING
There are no hardware options on the Quad R-POTS access module. The Quad
R-POTS access module is provisioned by connecting a VT100 terminal or a computer
running a terminal emulation program to the craft interface ADMIN port located on the
System Controller Unit (SCU) front panel. Connection to the port is achieved by using
a male-ended RS-232 DB-9 cable. Craft port settings are as follows:
♦ 9600 Baud
♦ No Parity
♦ 8 Data Bits
♦ 1 Stop Bit
♦ No Flow Control
1
INSTALLATION
2
After unpacking the Quad R-POTS access module, inspect it for damage. If damage
has occurred, file a claim with the carrier then contact ADTRAN Customer Service.
Refer to the Warranty information on the following page.
The Quad R-POTS inserts into any access module slot (1 through 24, 23-inch chassis
or 1 through 18, 19-inch chassis) of the Total Access 1500 chassis.
Gently, but firmly, push the Quad R-POTS into any slot on the shelf. Simultaneous
thumb pressure at the top and bottom of the Quad R-POTS will ensure a good seat of
the Quad R-POTS pins into the backplane connector. Push the ejector latch up and
closed against the Quad R-POTS front panel to lock it in place.
When the Quad R-POTS first powers up it performs a power up self-test. Once the
power up self-test is complete, the status LEDs will reflect the true state of the
hardware.
Windows HyperTerminal can be used as a VT100 terminal emulation program. Open
HyperTerminal by selecting Programs/Accessories/HyperTerminal. Refer to the Help
section of HyperTerminal for additional information.
NOTE: To ensure proper display background, select VT100 terminal emulation under
Settings.
FRONT PANEL LEDS
Menu Navigation
3
*61180408L1-22D*
4
Busy 1-4
!
"
Windows HyperTerminal
Off..............On hook
Green .........Off hook or in test mode
TIME SLOT ASSIGNMENTS
The Total Access 1500 platform can have multiple time slots in the T1 data stream
assigned to each physical slot in the channel bank. The system will automatically map
DS0s in the T1 as determined by the Line Interface Unit (LIU) operational
configuration. Manual mapping is available via the LIU menu.
CONNECTIONS
C A U T I O N !
Four 50-pin male amphenol connectors on the 23-inch Total Access 1500 backplane
and three on the 19-inch chassis backplane provide the interconnect wiring for the four
analog circuits on each access module. For each physical slot on the 23-inch chassis,
Password and User ID
Password protection is a function of the SCU and is factory disabled. If password
authentication is enabled, then the SCU will display the Logon screen. A valid user
name and password are required to access the menus.
NOTE: The default user name is “user”, and the default password is “password”.
The user name and password are not case sensitive.
To traverse through the menus, select the desired entry and press ENTER. To work
backward in the menu press the ESC key.
The menu tree on the reverse page illustrates the path to every provisioning,
performance, and test access point in the Quad R-POTS menu.
TEST FEATURES
The Quad R-POTS supports a Digital Network Loopback Test, 1004 Hz Tone
Generation Test, Network Hook Test, and Customer Ringing Test for each circuit to
support circuit turnup and maintenance efforts. These tests are initiated from the Total
Access 1500 local craft port on the SCU or remotely via Telnet or SNMP, and are
initiated on an individual port basis. The tests are described below.
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
For more information, refer to the Installation and Maintenance Practice (P/N 61180408L1-5) available online at www.adtran.com.
PRICING AND AVAILABILITY 800.827.0807
TECH SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
www.adtran.com
61180408L1-22D
Total Access 1500 Quad R-POTS
Digital Network Loopback Test
The Digital Network Loopback test activates a loopback path that takes the DS0 data received from the
network and transmits it back to the network in the appropriate transmit time slot.
1. Loop Start
1. Configuration
1004 Hz Tone Test
The 1004 Hz Tone Generation Test generates a 1004 Hz Digital Reference Signal (DRS) tone toward
the T1 network (0 dBm fixed), toward the customer loop (RX TLP setting), or both directions
simultaneously. While sending the DRS tone toward the customer loop the transmit audio path
(towards the T1 network) will be interrupted.
2. Ground Start
3. TR08 Single Party
Unit Name
CLEI Code
Part Number
Software Revision
1. Circuit 1
2. Circuit 2
3. Circuit 3
1. Circuit
4. Circuit 4
4. TR08 Universal VG
5. TR08 Auto
6. PLAR D4
7. PLAR D3
8. Tandem
9. DPO
2. Provisioning
2. Mode
10. FX Ringdown
11. TO w/SC
1. 600 ohms + 2.16 µF
3. 2-Wire Line Impedence
Network Hook Test
2. 900 ohms + 2.16 µF
4. Transmit TLP
The Network Hook Test forces the AB signaling states towards the T1 network. The bits are set based
upon the operating mode of the channel unit.
Enter Value (-7.0...+9.0)
1. Circuit
5. Receive TLP
Enter Value (-9.0...+0.0)
6. Trunk Processing
Customer Ringing Test
4. Circuit 4
2. Idle in CFA
1. Tandem Inactive
2. Enabled
8. NBOC
Enter Value (0 ... 126)
(1)
9. Ring Back Tone Generation
Metallic Test Access
This option is used in conjunction with a List 3 SCU P/N 1180008L3, 1180008L3#S or 1180008L23 to
provide automatic Mechanized Loop Testing (MLT).
1. Disabled
7. On-Hook Messaging
9. Tandem Mode Options
Power Code
Input
Output
C
C
Telecommunication Code (TC)
–
X
Installation Code (IC)
A
–
5. Dial Tone Generation
Mode
2-Wire Termination
Transmit TLP
Receive TLP
Trunk Processing
1. Circuit
1. Circuit 1
2. Circuit 2
3. Circuit 3
4. Circuit 4
2. Digital Network Loopback Test
On-Hook Messaging
NBOC
Signal Bits TX/RX
Digital Test
Metallic Test
4. Test
5. Customer Ringing Test
2. Wink Start
1. Normal Battery
2. Reverse Battery
1. Disabled
2. Enabled
1. Disabled
2. Enabled
2. 500 msec
3. 750 msec
1. Disabled
8. DNIS Protocol
1. Inactive
2. To Network
3. To Loop
1. Immediate Start
4. 1 second
5. 2 seconds
2. DNIS Enabled
3. DNIS Enabled - No Answer
1. 0.5 seconds
2. 1.0 seconds
3. 1.5 seconds
1. No Test
3. 1004 Hz Tone Test
2. Loop Start
3. Ground Start
1. 250 msec
7. Forward Disconnect Delay
2. Active
4. Network Hook Test
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by ADTRAN could void the user’s authority to
operate this equipment.
4. Tandem Battery
6. Ring Back Tone Generation
COMPLIANCE
Code
2. Enabled
3. Status
The Quad R-POTS complies with the requirements covered under UL 60950 and is intended to be
installed in restricted access areas only and in equipment with a Type “B” or “E” enclosure. The Total
Access 1500 chassis frame ground terminal must be connected to an earth ground to ensure that the
front panel of the Quad R-POTS is properly grounded via the backplane connector.
3. Supervision
1. Disabled
(2)
Circuit 1-4
2. Circuit 2
3. Circuit 3
1. Busy in CFA
2. Conversion Mode
The Customer Ringing Test activates the port’s ring relay in a 2-second on and 4-second off cadence,
providing ringing toward the customer’s loop.
NOTE: The tests cannot run simultaneously. If a test is in progress and another test is initiated, the
first test will be terminated when the new test starts.
1. Circuit 1
4. To Loop and Network
4. 2.0 seconds
5. 2.5 seconds
1. No Test
6. 3.0 seconds
7. 3.5 seconds
2. On-Hook
3. Off-Hook
8. 4.0 seconds
(3)
9. DNIS Delay
1. No Test
2. Ringing
6. Metallic Test Access
1. Inactive
2. Full Split
(1) If Mode = PLAR or FX Ringdown
(2) If Mode = Tandem
(3) If DNIS Protocol = DNIS Enabled or DNIS Enabled - No Answer
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service.
Warranty information can be found online at www.adtran.com/warranty.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising