ADTRAN | TOTAL ACCESS 4303 STS-1 | Quick Start Guide | Adtran TOTAL ACCESS 4303 STS-1 Quick Start Guide

Adtran TOTAL ACCESS 4303 STS-1 Quick Start Guide
For more detailed documentation, visit us online at www.adtran.com
Quick Start
Technical Support (888) 4ADTRAN (423-8726)
61200352L1-13B
November 2001
Copyright © 2001 ADTRAN All rights reserved
TOTAL ACCESS® 4303 STS-1 MODULE
CLEI Code: SLL35Y0J_ _
STS-1
1200352L1
FACEPLATE LEDS
INSTALLATION INFORMATION
ONLINE LED
Description
Off
Blown fuse or no power supplied to the shelf
• Insert the module into the desired slot (1 through 4 only)
(hot insertion permissible).
Green
Online
Blinking Green
Offline
ONLINE
Red
Card failure
STATUS
Blinking Red
Self-test failure
STS-1
Amber
Self-test in progress
CLOCK
STS-1 LED
Description
Off
STS-1 not configured for use
Green
STS-1 signal present & synchronized; channel is
configured for use
Red
STS-1 alarm present
Blinking Red
STS-1 performance error
Amber
STS-1 test in progress (includes port
self-test)
• The module connects to connectors on the backplane.
Connecting the BNC Module (P/N 1200323L1) to the connectors
provides two dual BNC connectors (see the
BNC Module Quick Start, 61200323L1-13A).
• The TA 4303 SCU automatically detects the presence of the
module. You do not need to reboot.
• Once installed, use the terminal menus to configure and control
the module (see the SCU Quick Start, 61200334L1-13A).
• Use the arrow keys on your VT-100 terminal keyboard to move
to the Modules menu; press Enter in the Menu column of the
appropriate module.
SPECIFICATIONS
Framing
STATUS LED
Description
Green
Active STS-1 Module
Blinking Green
Stand-by STS-1 - redundancy enabled
Blinking Red
Stand-by STS-1 - cannot automatically become
the active STS-1 while the current active STS-1
is installed
Tests
Amber
DS1 test in progress
CLOCK LED
Description
Off
No clock alarm condition detected
Yellow
Holdover mode
Blinking Yellow
Clock out of range or out of lock
Line Rate
Terminating
Impedance
Power
Compliance
Temperature
The TA4303 STS-1 Module requires
SCU firmware of D.01 or greater.
Line Coding
Line Build Out
Relative Humidity
Warranty
STS-1 Asynchronous mapping
D4, B8ZS (DS-1)
B3ZS (STS-1)
0 to 225 feet (<225 ft)
226 to 450 feet (> 225 ft)
Self-test
STS-1 Loopbacks
DS-1 Loopbacks
51.840 Mbps + 20 PPM
75 ohms + 5%, unbalanced
10 watts
FCC Part 15, UL 60950
Operation: 0 to 50 oC
Storage: – 20 to 70 oC
To 95% noncondensing
10 years
Quick Start
Technical Support (888) 4ADTRAN (423-8726)
61200352L1-13B
November 2001
Copyright © 2001 ADTRAN All rights reserved
TOTAL ACCESS 4303 STS-1 MODULE
MENU TREE FOR THE STS-1 MODULE TERMINAL MENUS
Slt
Module Info
Part Number
Type
Modules
Menu
STS Info
State
STS Alarms
Rev
Clr
CV_P
Clock Status
Normal
Board Revision
Out of Lock
CLEI Code
LOS
Out of Range
SES_P
LOF
Recovering
UAS_P
LOMF
Loss of Source
CV_S
Alarm
Test
Serial Number
ES_P
LOP
RDI_L
ES_S
AIS_L
RDI_P
SES_S
Clr
AIS_P
RFI_P
CV_L
CV_P
ES_P
STS Rem Alarms
UEQ_P
Current
ES_L
SLM_P
15 Min
SES_L
24 Hr
UAS_L
STS Perf (NearEnd)
STS Perf (FarEnd)
STS Config
LBO
Tx Label
Tx Clock
Rx Label
UAS_P
15 Min
CV_L
24 Hr
ES_L
<225 ft
>225 ft
STS Label
SES_P
Current
SES_L
Loop Timed
UAS_L
Free Run
None
External
Diag
STS Test
LoopBack
Terminal
Prt
Facility
RED
Clr
Alarm
Prt
YELLOW
ES
DS0 Status
Alarms
BLUE
BES
DS0 Alarm
SES
DS0 Alarm
Sig Status
SEFS
Perf (Current, 15 min, 24 hr)
LOFC
CSS
Prt
Prt
Port Name
Config
Loc LB
Frame
D4
Tx Yel
Test
Redundancy
Accept
LB Accept
Ignore
UAS
Line
PCV
Pay ld
ESF
Tx PRM
None
Remote LB
None
Pattern
Rmt Mgmt
Disable
ADLP
Enable
All Ones
Disabled
All Zeros
QRSS/RLB Results
QRSS
1E-03
Module Redundancy
1E-04
Clr
Error Threshold
1E-05
Inj
Minimum Switch Time
1E-06
Switch Count
Force Switchover