CyberData | 011377 | Quick Start Guide | Cyberdata 011377 InformaCast® Enabled RGB (Multi-Color) Strobe Quick Start Guide

Cyberdata 011377  InformaCast® Enabled RGB (Multi-Color) Strobe Quick Start Guide
The IP Endpoint Company
Singlewire RGB Strobe
Quick Start Guide
1.0 Out-of-Box and Prior to Final Installation
1.1. Verify that you have received all of the parts listed on the Installation Quick
Reference placemat.
1.2. Download the current manual, otherwise known as an Operation Guide,
which is available in the Downloads tab on the following webpage:
http://www.cyberdata.net/voip/011377/
Note
You can also navigate to the Downloads tab by going to
www.CyberData.net and following the steps that are indicated by
the following figures:
2
1
3
Singlewire InformaCast
RGB Strobe
4
Part Number: 011377
2.0 Select Power Source
PoE Switch
PoE Injector
Set PoE power type to Class 0 = 13W
CAT6 cable recommended—
for longer distances
Be sure you are using a non-PoE switch or port
Make sure port is not in trunk mode
Set port to full duplex/ 100Mbps
Quick Start Guide
931308B
3.0 Power Test
3.1. Plug in the CyberData device and monitor the LED activity above the
ethernet port on the back of the Singlewire RGB Strobe. See the following
figure:
Link
Activity
3.2. The GREEN Link LED blinks off once during the boot up process and then
comes on again and remains constant (solid GREEN). The YELLOW
Activity LED may be blinking depending on the network activity.
Normally, this process will take about 30 seconds. However, if no DHCP is
available, then this process could take up to 2 minutes.
This concludes the power test. Go to Section 4.0, "InformaCast
Configuration File Retrieval".
Quick Start Guide
931308B
4.0 InformaCast Configuration File Retrieval
4.1. DHCP should be enabled. After the device initializes, it will send a
broadcast to the DHCP server to ask for the location of its
InformaCastSpeaker.cfg configuration file.
4.2. SLP or TFTP?
•
SLP should be enabled on InformaCast version 5.0.4 or higher. SLP is an
InformaCast protocol introduced in InformaCast version 5.0.4. The device will
retrieve its configuration file from an InformaCast server folder specified by
SLP. SLP method is preferred.
•
TFTP servers may be used instead of SLP. In this alternate scenario, DHCP
option 150 is required to provide the device with the address of the TFTP
server. Otherwise, the device will be unable to retrieve its configuration file.
Note The device and InformaCast server should be on the same subnet
during the device's initial configuration if it cannot access the
VLANs upon which the InformaCast Server and DHCP servers are
located. It may be necessary to manually configure your switch
port to allow access to the VLAN.
5.0 Singlewire-Enabled Singlewire RGB Strobe
Identification and Testing
5.1. Ensure the InformaCast Server has detected a new device.
5.2. Test the newly detected device.
5.3. Add the newly detected device to the InformaCast Server.
Quick Start Guide
931308B
6.0 Contacting CyberData VoIP Technical Support
We encourage you to access our Technical Support help desk at the following
address:
http://support.cyberdata.net/
Note You can also access the Technical Support help desk by navigating through
menus on the CyberData website (www.CyberData.net) as shown in the
following figure:
The Technical Support help desk provides the options of accessing
documentation for your CyberData product, browsing the knowledge base, and
submitting a troubleshooting ticket.
Please be advised requests for Returned Materials Authorization (RMA) numbers
require an active VoIP Technical Support ticket number. A product will not be
accepted for return without an approved RMA number.
Quick Start Guide
931308B
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertising