CyberData | 011403 | Quick Reference | Cyberdata 011403 InformaCast® Enabled Paging Amplifier Quick Reference

Cyberdata 011403  InformaCast® Enabled Paging Amplifier Quick Reference
Dimensions
Installation Quick Reference
The IP Endpoint Company
ø0.172 [ø4.4]
(2 Places)
011403
CLASS II WIRING
MIC IN
3
2
1
STROBE
5
4
3
2
1
InformaCast Enabled Paging Amplifier
Parameter
Factory Default Setting
IP Addressing
DHCP
IP Address
a
10.10.10.10
Web Access Username
admin
Web Access Password
admin
Subnet Maska
255.0.0.0
a
10.0.0.1
7.303 [185.5]
7.795 [198.0]
Default Gateway
SAFETY WARNING!
Please read the owner’s manual for proper
installation. Incorrect wiring can lead to
and/or other attached components.
a. Default if there is not a DHCP server present.
Typical System Installation
802.3at Compliant PoE Ethernet Switch
CLASS II WIRING
*See the Operations Guide for more
installation options.
Mono(+)/Left Spkr (+) - 12
Left Spkr (-) - 11
Right Spkr (+) - 10
Mono(-)/Right Spkr (-) - 9
Line-Out (+) - 8
Line-Out (-) - 7
Line-In (-) - 6
Line-In (+) - 5
Relay COM - 4
Relay NO/NC - 3
Door Sense/Button Common (GND) - 2
Door Sense/Button Contact (+) - 1
Optional 011471
IP66 Analog Horn
(sold separately)
www.cyberdata.net
0.326 [8.3]
1.042 [26.5]
InformaCast Server
InformaCast Enabled
Paging Amplifier
3.295 [83.7]
Dimensions are in Inches [Millimeter]
VoIP Phone
Getting Started
•
Download the Operations Guide PDF file from the Documents tab at the following webpage:
http://www.cyberdata.net/products/011403/
•
Create a plan for the locations of your paging amplifiers.
•
WARNING: This product should be installed by a licensed electrician according to all local electrical and building codes.
•
WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation
instructions.
•
WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.
•
WARNING: The InformaCast Enabled Paging Amplifier enclosure is not rated for any AC voltages!
Parts
Contacting CyberData
(1) Assembly
(2) Plastic Ribbed Anchors
Corporate Headquarters
CyberData Corporation
3 Justin Court
Monterey, CA 93940, USA
Phone: 831-373-2601
Fax: 831-373-4193
http://www.cyberdata.net/
(1) Screw Accessory Kit
(2) #6x1.25" Pan Head
Phillips Sheet Metal Screw
Sales: (831) 373-2601 ext. 334
Support: 831-373-2601 ext. 333
Support Website: http://support.cyberdata.net/
RMA Department: (831) 373-2601 ext. 136
RMA Email: RMA@CyberData.net
RMA Status: http://support.cyberdata.net/
Warranty Information: http://support.cyberdata.net/
© 2019, CyberData Corporation, ALL RIGHTS RESERVED
931271E
Quick Reference
Quick Reference
931271E
© 2019, CyberData Corporation, ALL RIGHTS RESERVED
Connection Options
Features
CLASS II WIRING
RTFM Switch
VoIP
Loudspeaker
RTFM
To broadcast a device’s current IP address, press and hold the
RTFM switch for a couple of seconds and then release it.
Mono(+)/Left Spkr (+) - 12
Left Spkr (-) - 11
Right Spkr (+) - 10
Mono(-)/Right Spkr (-) - 9
Line-Out (+) - 8
Line-Out (-) - 7
Line-In (-) - 6
Line-In (+) - 5
Relay COM - 4
Relay NO/NC - 3
Door Sense/Button Common (GND) - 2
Door Sense/Button Contact (+) - 1
To restore the factory defaults, complete the following steps:
1. Press and hold the RTFM switch until you hear the device
announce the words, “restoring defaults” and “rebooting”.
2. Release the RTFM switch. The device will be restored to the
factory default settings.
Speaker Volume
Speaker Connections*
*See the Operations Guide for diagrams and
information about the connections in this section.
Line-Out Connection (10K Ohm)
Line-In Connection
Relay Connection
Sensor Connection
Speed (SPD) LED (AMBER)
Volume
The Speed LED illuminates AMBER for a 100Mb link or is off for
a 10MB link when the network link to the device is established.
Relay Connection
SPD Link/Act.
Link/Activity (Link/Act.) LED (GREEN)
The Link/Act. LED blinks to indicate network traffic.
External device
such as an
electric door strike
or an LED strobe
light
PWR Status
High PIV Ultrafast
Switching Diode
Solid State or
Mechanical
Relay
OUT
IN
Status LED (GREEN)
After supplying power to the device, a steady GREEN Status
LED confirms that the device is operational.
AC or DC
Power
Source
Power (PWR) LED (GREEN/BLUE)
The PWR LED is a GREEN in low power mode (802.3af) and
BLUE during high power mode (802.3at).
Output Contacts
AC or DC-rated
depending upon
controlled device
requirements
Paging Amplifier
DC Power Supply
(Max. 30 VDC @ 1A)
Sensor Connection
Line-In Connection
Paging Amplifier
*See the Operations Guide for more information about the features in this section.
Optional 011471
IP66 Analog Horn
(sold separately)
When line-in is enabled on
the device, the audio
received from the line-in
connection will be played
to the speaker(s) and lineout connection as the
lowest priority audio.
© 2019, CyberData Corporation, ALL RIGHTS RESERVED
931271E
Quick Reference
Quick Reference
Paging Amplifier
Music Source
931271E
© 2019, CyberData Corporation, ALL RIGHTS RESERVED
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertising