CyberData | 011412 | Owner Manual | Cyberdata 011412 Syn-Apps enabled Loudspeaker Amplifier-AC-Powered Owner manual

Cyberdata 011412 Syn-Apps enabled Loudspeaker Amplifier-AC-Powered Owner manual
Installation Quick Reference
Mounting the Enclosure
Syn-Apps enabled Loudspeaker
Amplifier (AC-Powered)
To mount the enclosure:
1. Prepare holes for the screws.
2. Plug in the power adapter and use
the Power (PWR) LED to verify that
the power is on.
011412
3. Plug the ethernet cable into the
device. The Link/Activity (Link/
Act.) LED verifies the network
connection.
Parameter
Factory Default Setting
IP Addressing
DHCP
a
10.10.10.10
IP Address
4. For wall mounting, use the three
#8 x 1-1/4-inch Pan Head Phillips
Self-Tapping Screws.
Web Access Username
admin
Web Access Password
admin
Subnet Maska
255.0.0.0
a
10.0.0.1
Default Gateway
a. Default if there is not a DHCP server present.
Getting Started
•
Download the Syn-Apps enabled Loudspeaker Amplifier Operations Guide PDF file from the Documents tab at the
following webpage: https://www.cyberdata.net/products/011412
•
Create a plan for the locations of your paging amplifiers.
•
WARNING: This product should be installed by a licensed electrician according to all local electrical and building codes.
•
WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the
installation instructions.
•
WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.
•
WARNING: The Syn-Apps enabled Loudspeaker Amplifier enclosure is not rated for any AC voltages!
Wiring the 125V AC Plug
The green wire with the yellow stripe is a ground connection for electrostatic discharge (ESD) protection,
and should not be removed.
To wire the 125V AC plug, consult a licensed electrician and the local building codes in your area.
Parts
(1) Assembly
(1) Wall Mounting Kit
(4) #8 Plastic Anchors
(4) #8 x 1-1/4" Pan Head Phillips Self-Tapping Screws
Contacting Syn-Apps
(1) Enclosure
Corporate Headquarters
Syn-Apps LLC
2812 N Norwalk
Suite 112
Mesa, AZ 85215
Phone: 480-664-6071 / 866-664-6071
Fax: 480-659-8999 / 866-659-8999
© 2018, Syn-Apps L.L.C. ALL RIGHTS RESERVED
Website: www.syn-apps.com
Additional Parts
(1) CAT 5e/CAT6 cable
(1) PoE Power Injector
(1) IEC Power Cord
(1) Universal Receptacle
Sales: sales@syn-apps.net
Support: http://www.syn-apps.com/resources/support
Email: http://www.syn-apps.com/contact-us
931318D
Quick Reference
Quick Reference
931318D
© 2018, Syn-Apps L.L.C. ALL RIGHTS RESERVED
Dimensions
Features
RTFM Switch
VoIP
Loudspeaker
To broadcast the device’s current IP address, press and hold the RTFM switch for a couple
of seconds and then release it.
To restore the factory defaults, complete the following steps:
RTFM
11.81 [300]
1. Press and hold the RTFM switch until you hear the device announce the words,
“restoring defaults” and “rebooting”.
2. Release the RTFM switch. The device will be restored to the factory default settings.
Speaker Volume
Speed (SPD) LED (AMBER)
The Speed (SPD) LED illuminates AMBER for a 100Mb link
Volume
Notes:
1. Dimensions
are in inches
[millimeters].
or is off for a 10MB link when the network link to the device is established.
SPD Link/Act.
Link/Activity (Link/Act.) LED (GREEN)
The GREEN Link/Activity (Link/Act.) LED blinks to indicate network traffic.
2. Projection:
Third Angle
PWR Status
5.12 [130]
7.87 [200]
Mounting Bracket
Status LED (GREEN)
The GREEN Status LED illuminates after supplying power to the device.
Power (PWR) LED (GREEN/BLUE)
The Power (PWR) LED is GREEN in low power mode (802.3af)
and BLUE during high power mode (802.3at).
*See the Operations Guide for more information about the features in this section.
Enclosure Features
COVER OPEN LEFT
LATCHES
HINGES
Pull the mounting bracket
outward while tightening the
screw. Do the same to all
four mounting brackets.
THREE CABLE GLAND WITH
ONE HOLE PLUG
© 2018, Syn-Apps L.L.C. ALL RIGHTS RESERVED
931318D
Quick Reference
Quick Reference
931318D
© 2018, Syn-Apps L.L.C. ALL RIGHTS RESERVED
Mounting Template
9.92 [252]
Mounting Hole (11/64”, 0.172” or 4.4mm)
fit #8 Screw or 4mm Screw
In Order to Assure Size Accuracy,
Make Sure that PAGE SCALING is Select to NONE
Prior to Printing this Mounting Template.
Change this Settings by Selecting:
File, Print - PAGE HANDLING - Page Scaling to NONE.
Click on "Properties" Tab
Change the Paper Size to 11" x 17" or
A3 (297mm x 420mm)
After Printing, Verify that Size is Correct by
Checking Scale on Printed Page.
8.5 [216]
DIMENSIONS ARE IN INCHES [MILLIMETER]
© 2018, Syn-Apps L.L.C. ALL RIGHTS RESERVED