CyberData | 011375 | Owner Manual | Cyberdata 011375 Network Dual Door Strike Relay Owner manual

Cyberdata 011375 Network Dual Door Strike Relay Owner manual
LED Behavior
Installation Quick Reference
Status and Link LEDs (at J1):
LED Behavior
The IP Endpoint Company
Network Dual Door Strike Relay
011375
Parts List
•
(1) Network Dual Door Strike Relay
•
(1) Accessory Kit
•
(2) Cable Clamps
Means
The AMBER Status LED is on and the GREEN Link LED is on and blinking. No fault detected. The device is on the network
and the device is not active.
Note: On boot, within approximately three seconds, the AMBER Status LED and the GREEN Link LED come on with the
GREEN Link LED beginning to blink almost immediately.
Board LED (DS1):
LED Behavior
Means
On and solid RED
No fault detected. A relay is not engaged.
Power Input
PoE IEEE 802.3af
On and solid GREEN
No fault detected. A relay is engaged.
Operating temperature
-10o C to 50o C (14o F to 122o F)
One long RED flash and a short RED flash
Device hardware fault, communication error
Relay Voltage/Current
12 A @ 250 VAC / 12 A @ 24 VDC
One long RED flash and one short AMBER flash
Device hardware fault, communication error
One long RED flash and two short AMBER flashes
Device hardware fault, memory error
One long RED flash and three short AMBER flashes
Device hardware fault, fuse
Warning
One short RED flash and one short AMBER flash
Network address, DHCP Issue
Electrical Hazard: Hazardous voltages may be present. No user serviceable
Specifications
part inside. Refer to qualified service personnel for connecting or servicing.
Note: On boot, the board LED blinks RED once, and then remains on and solid RED until a relay is engaged.
GENERAL ALERT
Getting Started
•
Download the Operations Guide PDF file, from the Downloads tab at:
http://www.cyberdata.net/voip/011375/
•
WARNING: This product should be installed by a licensed electrician according to all local
electrical and building codes.
•
WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in
accordance with the installation instructions.
•
WARNING: The PoE connector is intended for intra-building connections only and does
not route to the outside plant.
•
WARNING: This enclosure is not rated for any AC voltages!
AMBER Status LED
Board LED (DS1)
(RED or GREEN)
GREEN Link LED
Firmware Version
Details
For legacy Networked Door Strike Relays (011270), the relay operates in Single Mode. Keypad
versions of the intercom may be configured to activate a single DSR, either a 011375 in Single
Mode, or a 011270. The user has the option to use enter a code from the keypad to either
activate the relay for a specified time, or to use a code to activate the relay until the deactivation
code is entered. Intercoms running version 11.7.0 or later must run the Network Dual Door
Strike Relay with version 4.8 or later, and version 4.8 or later DDSRS must run with version
11.7.0 or later intercoms.
Contacting CyberData
Corporate Headquarters
CyberData Corporation
3 Justin Court
Monterey, CA 93940, USA
Phone: 831-373-2601
Fax: 831-373-4193
http://www.cyberdata.net/
Sales: (831) 373-2601 ext. 334
Support: 831-373-2601 ext. 333
Support Website: http://support.cyberdata.net/
RMA Department: (831) 373-2601 ext. 136
RMA Email: RMA@CyberData.net
RMA Status: http://support.cyberdata.net/
Warranty Information: http://support.cyberdata.net/
© 2017, CyberData Corporation, ALL RIGHTS RESERVED
931207F
CyberData has streamlined the Network Dual Door Strike Relay (011375) functions with
release 11.7.x and later of the SIP and Singlewire intercom line of products. The Network Dual
Door Strike Relays operate in three modes: Manual Mode, Automatic Mode, and Single Mode
(more details are in the Operations Guide).
For the most up to date information, please refer to our website:
http://www.cyberdata.net/voip/011375/
Quick Reference
Quick Reference
931207F
© 2017, CyberData Corporation, ALL RIGHTS RESERVED
Network Dual Door Strike Relay Wiring Diagram with External Power Source
Dimensions
802.3af Compliant Ethernet Switch
CyberData
Device
+
The relay connection maximum wire
size is 12 gauge stranded wire.
AC Source 2
Door Strike
Door Strike
DC Source 2 OR
4.3 [110.2]
2.2 [55.1]
ø0.2 [ø4.8]
(2 Places)
+
AC Source 1
DC Source 1 OR
*
*
6.1 [154.9]
6.6 [167.3]
1.8 [46.6]
Mounting Holes fit #6 to #8 Screw
Dimensions are in Inches [Millimeter]
See the Network Dual Door Strike Relay
Operations Guide for connection specifics.
Sense Input 1
Assembly
Aux Button1
Sense Input 2
Aux Button 2
*Caution
GENERAL ALERT
Equipment Hazard: The door strike must have an internal or external mov or
diode (for over voltage protection) when connecting directly to the module.
Network Dual Door Strike Relay Wiring Diagram Using PoE+
802.3at Compliant Ethernet Switch
CyberData
Device
The relay connection maximum wire
size is 12 gauge stranded wire.
Door Strike
Internal 12VDC
source (500 mA
maximum)
Door Strike
A size 1 Phillips screwdriver for the
cover screws
*
*
A 3.17 mm (1/8-inch) flat blade
screwdriver for the terminal
block screws
Tools required for assembly:
A 3.17-mm (1/8-inch) flat
blade screwdriver for the
terminal block screws
See the Network Dual Door Strike Relay
Operations Guide for connection specifics.
Sense Input 1
Sense Input 2
Aux Button 2
*Caution
A size 1 Phillips screwdriver
for the cover screws
GENERAL ALERT
© 2017, CyberData Corporation, ALL RIGHTS RESERVED
Aux Button1
931207F
Quick Reference
Quick Reference
Equipment Hazard: The door strike must have an internal or external mov or
diode (for over voltage protection) when connecting directly to the module.
931207F
© 2017, CyberData Corporation, ALL RIGHTS RESERVED