Mounting Options—Metal Bracket
Installation Quick Reference
Wall Plate Mounting Bracket (Metal)
To be installed and or used in accordance with the
appropriate electrical codes and regulations.
Bend Tabs Up/Down
Against Inside Wall
to Secure Bracket
Wall Opening
One-Gang
Low Voltage
One-Gang
Low Voltage
Mounting
MountingBracket
Bracket
(Metal) (Metal)
Mounting
Screw (2x)
Tools Required: Wall board saw, Pliers
VoIP Remote Call Button
Instructions:
011185/071012, RAL 9003, Signal White
1. Use the inside area of the bracket to trace the hole
cut onto the wall.
Typical Installation
2. Using a wall board saw or matt knife, cut along the
stencil line.
Wall
Opening
Gasket
The IP Endpoint Company
Bend tabs up and
down against
inside wall to
secure bracket.
802.3af Compliant Ethernet Switch
1
2
3
4
5
6
3. Place bracket against the wall opening.
4. Bend tabs up and down against the inside wall to
secure the bracket.
5. Place the optional gasket over the metal bracket.
Remote
Call Button
Assembly
Mounting
Screw (2x)
Optional
Gasket
6. Mount the flush mount wall plate to the bracket.
Remote Call Button
Speaker
IP Phone
IP PBX Server
Remote Call
Button Assembly
Getting Started
Mounting Options—Plastic Bracket
•
One-Gang
One-Gang
Low Voltage
Low Voltage
Mounting Bracket
Mounting (Plastic)
Bracket
(Plastic)
Mounting
Screw (2x)
Wall Opening
Mounting
Screw (2x)
Create a plan for the locations of your speakers.
•
WARNING: This product should be installed by a licensed electrician according to all local electrical and building codes.
Instructions:
•
1. Use the inside area of the bracket to trace the hole
cut onto the wall.
WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation
instructions.
•
WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.
•
WARNING: The Call Button enclosure is not rated for any AC voltages!
2. Using a wall board saw or matt knife, cut along the
stencil line.
Tighten Screws
to Pull
WingNutsscrews to
Tighten
Against
Inside Wall
to Secure
pull Bracket
Flagnuts against
Remote
Call Button
Assembly
•
Tools Required: Wall board saw, Philips screwdriver
Wall
Opening
Gasket
inside wall to secure
bracket.
Optional
Gasket
http://www.cyberdata.net/products/voip/accessories/remotebutton/docs.html
Wall Plate Mounting Bracket (Plastic)
To be installed and or used in accordance with the
appropriate electrical codes and regulations.
Download the VoIP Remote Call Button Operations Guide PDF file from the Documentation page at:
3. Place bracket through the wall opening.
Parts
4. Tighten screws to pull Flagnuts against the inside
wall to secure the bracket.
(1) Call Button Assembly
5. Place the optional gasket over the plastic bracket.
Optional Parts (Not Included) (1) Optional One-Gang
Box (Metal)
(1) Optional Gasket
(1) Optional One-Gang
Box (Plastic)
6. Mount the flush mount wall plate to the bracket.
Remote Call
Button Assembly
Contacting CyberData
(1) Wall Mounting Kit
Corporate Headquarters
CyberData Corporation
3 Justin Court
Monterey, CA 93940, USA
Phone: 831-373-2601
Fax: 831-373-4193
http://www.cyberdata.net/
930464D
(1) Optional One-Gang, Low Voltage,
Mounting Bracket (Plastic)
(2) Mounting screws
Sales: (831) 373-2601 ext. 334
Support: 831-373-2601 ext. 333
Support Website: http://support.cyberdata.net/
RMA Department: (831) 373-2601 ext. 136
RMA Email: RMA@CyberData.net
RMA Status: http://support.cyberdata.net/
Warranty Information: http://support.cyberdata.net/
© 2015, CyberData Corporation, ALL RIGHTS RESERVED
(1) Optional One-Gang, Low Voltage,
Mounting Bracket (Metal)
Quick Reference
Quick Reference
930464D
© 2015, CyberData Corporation, ALL RIGHTS RESERVED
Dimensions
Connections
4.62 [117.5]
1.17 [29.7]
Speaker
AUX POWER (+)
(+12VDC @ 1A)
AUX SPEAKER (-)
AUX SPEAKER (+)
GND
LINE OUT (-)
LINE OUT (+)
BUTTON LED (-)
AUX POWER (-)
RELAY COM
RELAY NO
BUTTON LED (+)
BTN SENSE
J10
SIDE VIEW
2.87 [73.0]
DIMENSIONS ARE IN INCHES [MILLIMETER]
J9
CLASS II WIRING
Mounting Options—One-Gang Box (Metal or Plastic)
To be installed and or used in accordance with the
appropriate electrical codes and regulations.
Back View
Wall Plate Mounting Bracket
One-Gang Box (Metal or Plastic)
Tools Required: Wall board saw
Instructions:
One-Gang Box
(Plastic)
1. Use the outside area of the One-Gang Box to trace
the hole cut onto the wall.
One-Gang Box
(Plastic)
2. Using a wall board saw or matt knife, cut along the
stencil line.
3. Place One-Gang Box through the wall opening.
Mounting Gasket
Screw (2x)
4. Optional: Nail the One-Gang Box to the stud or
connect it to the set screw connect and conduit.
Wall
Opening
Wall Opening
One-Gang Box
One-Gang
(Metal) Box
(Metal)
Remote
Call Button
Assembly
Mounting
Remote Call
Screw (2x)
5. Place the optional gasket over the One-Gang Box.
6. Mount the flush mount wall plate to the One-Gang
Box.
Optional
Gasket
Button Assembly
© 2015, CyberData Corporation, ALL RIGHTS RESERVED
930464D
Quick Reference
Quick Reference
930464D
© 2015, CyberData Corporation, ALL RIGHTS RESERVED
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising