Hanna Instruments HI38041 Owner Manual
Hanna Instruments HI38041
Hanna Instruments HI38041 Iron High Range Test Kit with Checker Disc is a simple and easy-to-use kit that determines the iron concentration in water. The kit uses a colorimetric method to determine the iron level, and the results are displayed on a checker disc. The kit is designed to measure iron levels in the range of 0 to 10.0 mg/L (ppm) as Fe, with a smallest increment of 0.2 mg/L (ppm) Fe. The kit comes with 100 tests, and each test takes approximately 3 minutes to complete.
The HI38041 is ideal for use in a variety of applications, including:
- Environmental monitoring
PDF
Download
Document
Advertisement
Advertisement
Instruction Manual SPECIFICATIONS Range Smallest Increment Analysis Method Sample Size Number of Tests Case Dimensions Shipping Weight HI 38041 Iron High Range Test Kit with Checker Disc 0 to 10.0 mg/L (ppm) as Fe 0.2 mg/L (ppm) Fe Colorimetric 5 mL 100 235x175x115 mm (9.2x6.9x4.5") 980 g (34.6 oz) INSTRUCTIONS READ THE ENTIRE INSTRUCTIONS BEFORE USING THE KIT • Using the plastic pipette, fill each glass vial with 5 mL of sample (up to the mark). • Insert one of the vials into the left hand opening of the checker disc. This is the blank. • Keep the checker disc at a distance of 30-40 cm (12-16") from the eyes to match the color, while having a uniform background (e.g. a white sheet). Rotate the disc while looking at the color test windows and stop when you find the color match. Read the value in the result window and multiply it by 2 to obtain mg/L (or ppm) of Iron. 5 mL SIGNIFICANCE AND USE Generally, ground and surface water contains no more than 1 mg/L (ppm) iron; but due to mining and industrial drainage, higher levels of iron have been observed. Iron in water appears to be more of a nuisance than a hazard. The presence of iron can stain laundry and give water a bittersweet taste. The Hanna Test Kit determines the iron concentration in water by conversion of the ferrous (Fe2+) state. The test is fast and easy. The checker disc makes it simple to obtain the iron level in water. Note: mg/L is equivalent to ppm (parts per million). w w w. h a n n a i n s t . c o m Note: Any damaged or defective item must be returned in its original packing materials. CHEMICAL REACTION Iron can exist as ferrous (Fe2+) or ferric (Fe3+) ions. The Hanna Test Kit determines total iron levels in water via a colorimetric method. First all ferric ions are reduced by sodium sulfite to ferrous ions. Phenanthroline complexes with ferrous ion to form an orange colored solution. The color intensity of the solution determines the iron concentration. ISTR38041 09/13 Printed in ROMANIA Dear Customer, Thank you for choosing a Hanna Product. Please read the instructions carefully before using the chemical test kit. It will provide you with the necessary information for correct use of the kit. Remove the chemical test kit from the packing material and examine it carefully to make sure that no damage has occurred during shipping. If there is any noticeable damage, notify your Dealer or the nearest Hanna office immediately. If you need additional technical information, do not hesitate to e-mail us at [email protected] or view our worldwide contact list at www.hannainst.com. Each kit is supplied with: • HI 3834-0 Reagent, packets (100 pcs); • Deionized Water, 1 bottle (500 mL); • 1 checker disc (containing the 38040 disc); • 2 glass vials with caps; • 1 plastic pipette (3 mL); • 1 long plastic pipette. • Use the long plastic pipette to add to the other vial deionized water up to the 10 mL mark. Replace the cap and shake. 10 mL • Remove the cap and add 1 packet of HI 3834-0 reagent. Replace the cap and shake to mix. • Wait for 3 minutes to allow reaction to occur. This is the reacted sample. • Remove the cap and insert the reacted sample into the right hand opening of the checker disc. • Hold the checker disc so that a light source illuminates the samples from the back of the windows. For best results: Perform the reading three times and take the average value (divide by 3 the sum of the three numbers). Intensely colored samples will make the color matching difficult and they should be adequately treated before performing the test. Suspended matter in large amounts should be removed by prior filtration. Caution: Ultraviolet radiation may cause fading of colors. When not in use, keep the disc protected from light, in a cool and dry place. Interferences: Molybdate and Molybdenum above 50 ppm, calcium above 10000 ppm (as CaCO3), magnesium above 100000 ppm, chloride above 185000 ppm. REFERENCES 1987 Annual Book of ASTM Standard, Volume 11.01 Water (1), pages 531-535. Standard Methods for the Examination of Water and Wastewater, 16th Edition, pages 215-219. HEALTH AND SAFETY The chemicals contained in this kit may be hazardous if improperly handled. Read the relevant Health and Safety Data Sheet before performing this test. ">

Public link updated
The public link to your chat has been updated.
Advertisement