Central Machinery 5 ton 12 Amp Electric Log Splitter Owner's Manual
The Central Machinery 5 ton 12 Amp Electric Log Splitter is a powerful tool designed to split logs up to 20.5 inches long and 10 inches in diameter. It features a hydraulic system that delivers up to 5 tons of splitting force, making it ideal for splitting even the toughest hardwoods. With a 12 amp motor, it provides ample power for efficient operation. To prevent damage, ensure the hydraulic fluid level is checked before each use, and the vent plug is loosened before operation to avoid pressure buildup in the reservoir. This log splitter is a valuable asset for any homeowner or professional who needs to quickly and easily split firewood.
Advertisement
Advertisement
Owner’s Manual & Safety Instructions
Save This Manual
Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product’s serial number in the back of the manual near the assembly diagram (or month and year of purchase if product has no number).
Keep this manual and the receipt in a safe and dry place for future reference.
19b
Visit our website at: http://www.harborfreight.com
Email our technical support at: [email protected]
When unpacking, make sure that the product is intact and undamaged. If any parts are missing or broken, please call 1-888-866-5797 as soon as possible.
Copyright
©
2016 by Harbor Freight Tools
®
. All rights reserved.
No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product described herein.
Tools required for assembly and service may not be included.
Read this material before using this product.
Failure to do so can result in serious injury.
SAVE THIS MANUAL.
table of contents
Specifications ............................................. 2
Safety ......................................................... 2
Setup .......................................................... 6
Operation .................................................... 8
Maintenance .............................................. 10
Parts List and Diagram .............................. 14
Warranty .................................................... 16
Specifications
Electrical Rating 120VAC / 60Hz / 12A
Motor No Load Speed
Log Capacity
3400 RPM
20.5" L x 10" Diameter
Hydraulic Fluid Capacity 3.4 Quarts (3.2 Liters)
WarninG SyMBOLS anD DEFinitiOnS
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
Addresses practices not related to personal injury.
iMpOrtant SaFEty inFOrMatiOn
General tool Safety Warnings
read all safety warnings and instructions.
Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
1. KEEP GUARDS IN PLACE and in working order.
2. KEEP WORK AREA CLEAN.
Cluttered areas and benches invite accidents.
3. DON’T USE IN DANGEROUS ENVIRONMENT.
Don’t use power tools in damp or wet locations, or expose them to rain. Keep work area well lighted.
4. KEEP CHILDREN AWAY. All visitors should be kept safe distance from work area.
5. MAKE WORKSHOP KID PROOF with padlocks, master switches, or by removing starter keys.
6. DON’T FORCE TOOL. It will do the job better and safer at the rate for which it was designed.
7. USE RIGHT TOOL. Don’t force tool or attachment to do a job for which it was not designed.
8. WEAR PROPER APPAREL. Do not wear loose clothing, neckties, rings, bracelets, or other jewelry which may get caught in moving parts. Nonslip footwear is recommended.
Wear protective hair covering to contain long hair.
Page 2
For technical questions, please call 1-888-866-5797.
Item 63366
9. ALWAYS USE SAFETY GLASSES. Also use face or dust mask if cutting operation is dusty. Everyday eyeglasses only have impact resistant lenses, they are NOT safety glasses. DON’T OVERREACH.
Keep proper footing and balance at all times.
10. MAINTAIN TOOLS WITH CARE. Keep tools sharp and clean for best and safest performance. Follow instructions for lubricating and changing accessories.
11. DISCONNECT TOOLS before servicing; when changing accessories, such as blades, bits, cutters, and the like.
12. REDUCE THE RISK OF UNINTENTIONAL
STARTING. Make sure switch is in off position before plugging in.
13. USE RECOMMENDED ACCESSORIES.
Consult the owner’s manual for recommended accessories. The use of improper accessories may cause risk of injury to persons.
14. NEVER STAND ON TOOL.
Serious injury could occur if the tool is tipped or if the cutting tool is unintentionally contacted.
15. CHECK DAMAGED PARTS. Before further use of the tool, a guard or other part that is damaged should be carefully checked to determine that it will operate properly and perform its intended function – check for alignment of moving parts, binding of moving parts, breakage of parts, mounting, and any other conditions that may affect its operation. A guard or other part that is damaged should be properly repaired or replaced.
16. NEVER LEAVE TOOL RUNNING
UNATTENDED. TURN POWER OFF.
Log Splitter Safety Warnings
For your Own Safety read instruction
Manual Before Operating Log Splitter.
1.
DO nOt OpEratE WitH any GuarD
DiSaBLED, DaMaGED, Or rEMOVED. Keep guards in place and in good working order.
2. Wear ANSI-approved safety goggles under full face shield, heavy-duty work gloves and steel-toe work boots during use.
3. Crushing hazard. Never place hands or feet between the log and splitter wedge, or between the log and the ram during the forward or reverse stroke.
4. Never place hands or body near a hydraulic fluid leak or check for a leak with hands or other body parts. High-pressure fluid can be forced under the skin resulting in serious injury.
5. Never split a log that contains any foreign materials (nails, for example).
6. Do not use Splitter on logs longer than 20.5" or with a diameter greater than 10".
7. Hold the rounded, bark side of logs when loading or positioning, never the ends. Never place hands or any body parts between a log and any part of the Log Splitter.
8. Never load or unload logs while the Ram is moving.
9. Do not attempt to split logs across the grain. Doing so will damage the Log Splitter and could cause pieces of log to be thrown, injuring the operator or bystanders.
10. Never attempt to split more than one log at a time.
A piece of log can unexpectedly be thrown from the machine, causing severe personal injury.
11. Remove split logs away from the Log
Splitter immediately. Split logs left near the Log Splitter are a tripping hazard.
12. The use of accessories or attachments not recommended by the manufacturer may result in a risk of injury to persons.
13. Set up and operate only on a flat, level, dry and solid surface with wheels chocked.
14. When servicing use only identical replacement parts.
15. Only use safety equipment that has been approved by an appropriate standards agency. Unapproved safety equipment may not provide adequate protection. Eye protection must be ANSI-approved and breathing protection must be NIOSH-approved for the specific hazards in the work area.
16. Stay alert, watch what you are doing and use common sense when operating a power tool.
Do not use a power tool while you are tired or under the influence of drugs, alcohol or medication.
A moment of inattention while operating power tools may result in serious personal injury. Industrial applications must follow OSHA guidelines.
17. Maintain labels and nameplates on the tool.
These carry important safety information.
If unreadable or missing, contact
Harbor Freight Tools for a replacement.
18. Avoid unintentional starting.
Prepare to begin work before turning on the tool.
Item 63366
For technical questions, please call 1-888-866-5797.
Page 3
Log Splitter Safety Warnings (continued)
19. This product is not a toy. Keep it out of reach of children.
20. People with pacemakers should consult their physician(s) before use. Electromagnetic fields in close proximity to heart pacemaker could cause pacemaker interference or pacemaker failure.
21. The warnings, precautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur.
It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator.
SaVE tHESE inStructiOnS.
Grounding instructions
tO prEVEnt ELEctric SHOcK anD DEatH FrOM incOrrEct
GrOunDinG WirE cOnnEctiOn rEaD anD FOLLOW tHESE inStructiOnS:
110-120 Vac Grounded tools: tools with three prong plugs
1. In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock.
This tool is equipped with an electric cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances.
2. Do not modify the plug provided – if it will not fit the outlet, have the proper outlet installed by a qualified electrician.
3. Improper connection of the equipment-grounding conductor can result in a risk of electric shock.
The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment-grounding conductor.
If repair or replacement of the electric cord or plug is necessary, do not connect the equipmentgrounding conductor to a live terminal.
4. Check with a qualified electrician or service personnel if the grounding instructions are not completely understood, or if in doubt as to whether the tool is properly grounded.Use only 3-wire extension cords that have 3-prong grounding plugs and 3-pole receptacles that accept the tool’s plug.
5. Repair or replace damaged or worn cord immediately.
Grounding pin
125 Vac 3-prong plug and Outlet
(for up to 125 Vac and up to 15 a)
Page 4
For technical questions, please call 1-888-866-5797.
Item 63366
6. This tool is intended for use on a circuit that has an outlet that looks like the one illustrated above in
125 Vac 3-prong plug and Outlet
. The tool has a grounding plug that looks like the plug illustrated above in
125 Vac 3-prong plug and Outlet
.
7. The outlet must be properly installed and grounded in accordance with all codes and ordinances.
8. Do not use an adapter to connect this tool to a different outlet.
Extension cords
1.
Grounded
tools require a three wire extension cord.
Double Insulated
tools can use either a two or three wire extension cord.
7. Make sure the extension cord is properly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualified electrician before using it.
2. As the distance from the supply outlet increases, you must use a heavier gauge extension cord.
Using extension cords with inadequately sized wire causes a serious drop in voltage, resulting in loss of power and possible tool damage.
(See table a.)
3. The smaller the gauge number of the wire, the greater the capacity of the cord. For example, a 14 gauge cord can carry a higher current than a 16 gauge cord.
(See table a.)
4. When using more than one extension cord to make up the total length, make sure each cord contains at least the minimum wire size required.
(See table a.)
5. If you are using one extension cord for more than one tool, add the nameplate amperes and use the sum to determine the required minimum cord size.
(See table a.)
6. If you are using an extension cord outdoors, make sure it is marked with the suffix “W-A” (“W” in
Canada) to indicate it is acceptable for outdoor use.
8. Protect the extension cords from sharp objects, excessive heat, and damp or wet areas.
taBLE a: rEcOMMEnDED MiniMuM WirE
GauGE FOr EXtEnSiOn cOrDS* (120/240 VOLt)
naMEpLatE aMpErES
(at full load)
EXtEnSiOn cOrD
LEnGtH
25´ 50´ 75´ 100´ 150´
0 – 2.0
18 18 18 18 16
2.1 – 3.4
3.5 – 5.0
5.1 – 7.0
7.1 – 12.0
12.1 – 16.0
18
18
18
18
14
18
18
16
14
12
18
16
14
12
10
16
14
12
10
-
16.1 – 20.0
12 10 -
* Based on limiting the line voltage drop to five volts at
150% of the rated amperes.
14
12
12
-
-
Item 63366
For technical questions, please call 1-888-866-5797.
Page 5
Symbology
Double Insulated
V
Volts
~
Alternating Current
a
Amperes
n0 xxxx/min.
No Load Revolutions per Minute (RPM)
Read the manual before set-up and/or use.
WARNING marking concerning Risk of Eye Injury. Wear ANSI-approved safety goggles with side shields.
WARNING marking concerning Risk of Facial Injury from flying debris.
Wear ANSI-approved full face shield.
WARNING marking concerning
Risk of Foot Injury. Wear steel-toe work boots.
WARNING marking concerning
Risk of Hand Injury. Wear heavy-duty work gloves.
WARNING marking concerning
Risk of Electric Shock.
Properly connect power cord to appropriate outlet.
WARNING marking concerning
Crushing Hazard. Keep hands and feet away from moving parts.
SaVE tHESE inStructiOnS.
Setup - Before use:
read the EntirE iMpOrtant SaFEty inFOrMatiOn section at the beginning of this manual including all text under subheadings therein before set up or use of this product.
tO prEVEnt SEriOuS inJury FrOM acciDEntaL OpEratiOn: release the power Switch of the tool off and unplug the tool from its electrical outlet before performing any procedure in this section.
note:
For additional information regarding the parts listed in the following pages, refer to the Assembly Diagram near the end of this manual.
assembly
1. Insert the Control Handle through the slot in the Shield and into the shaft on the Control Handle Bracket.
2. Turn the Control Handle to tighten in place.
control
Handle control Handle
Bracket
Shield
Page 6
For technical questions, please call 1-888-866-5797.
Item 63366
Functions
ram control
Handle cutting Wedge power
Switch power cord
Lift
Handle rubber
Feet
Guide plate
Vent plug
Dipstick
Front Leg
Item 63366
For technical questions, please call 1-888-866-5797.
Page 7
Operating instructions
read the EntirE iMpOrtant SaFEty inFOrMatiOn section at the beginning of this manual including all text under subheadings therein before set up or use of this product.
tool Set up
tO prEVEnt SEriOuS inJury FrOM acciDEntaL OpEratiOn: unplug the tool from its electrical outlet before performing any procedure in this section.
tO prEVEnt SEriOuS inJury:
DO nOt OpEratE WitH any GuarD DiSaBLED, DaMaGED,
Or rEMOVED. Keep guards in place and in good working order.
checking Hydraulic Fluid Level
iMpOrtant!
Before first use and before each use thereafter, check the hydraulic fluid level when fluid is cold. Operating without sufficient fluid in the reservoir can badly damage the pump.
1. Unplug the Power Cord.
2. Remove the Control Handle. Use the Lift
Handle to raise the Log Splitter to a standing position on the wheel end of the unit.
3. Remove the Dipstick from the fluid reservoir.
4. Wipe off the Dipstick and thread it back into the fluid reservoir. Remove and check to make sure the fluid level is within the two marks on the Dipstick.
note: two handed operation required.
11. Press and hold the Power Switch with one hand, then with the other hand, push down and release
Control Handle several times to bleed air.
12. Replace Vent Plug.
Dipstick
Lift Handle
Dipstick
Vent plug
Full Low
Figure a: Dipstick
5. If the fluid level is low, add AW32 hydraulic fluid (not included).
6. If the fluid level is within the two marks, wipe the Dipstick clean and replace it in the fluid reservoir and tighten securely.
7. Use the Lift Handle to return the unit to its normal, horizontal operating position.
8. Replace Control Handle.
9. Plug in the Power Cord.
10. Remove Vent Plug.
power
Switch
Figure B: checking / adding Fluid
Page 8
For technical questions, please call 1-888-866-5797.
Item 63366
Workpiece and Work area Set up
1. Designate a work area that is clean and well-lit.
The work area must not allow access by children or pets to prevent distraction and injury.
2. Route the power cord along a safe route to reach the work area without creating a tripping hazard or exposing the power cord to possible damage. The power cord must reach the work area with enough extra length to allow free movement while working.
3. There must not be objects, such as utility lines, nearby that will present a hazard while working.
4. Maximum log size for this Log Splitter is
20.5" long and 10" in diameter. Attempting to cut logs that exceed those measurements is dangerous and may damage the Log Splitter.
5. Use a chainsaw (not included) to cut logs square on each end before splitting. Log ends that are not cut square can slide out while splitting and cause a safety hazard or cause excessive force to Log Splitter components.
6. Never split a log that contains any foreign materials
(nails, for example). Do not use odd-shaped, uneven logs or logs that are knotted or curved.
General Operating instructions
1.
check the hydraulic fluid level; fill as necessary.
2. Place wheel chocks (not included) on each side of the wheels to keep the Log Splitter from moving.
3. Plug in the Power Cord.
4. Loosen the Vent Plug 5 complete turns.
nOticE: to prevent risk of permanent equipment damage, loosen Vent plug before operation. Operating the Log Splitter with the Vent plug closed will cause pressure to build up in the hydraulic reservoir which could damage seals and affect normal operation
.
5. Position log lengthwise in the direction of the grain between the Guide Plates. Place one end of log against the Cutting Wedge. The log must be stable so that it will split properly.
note: two handed operation required.
6. Press and hold the Power Switch with one hand, then with the other hand, push the Control Handle down to move the Ram forward into the log, driving it onto the Cutting Wedge, splitting the log.
7. Release the Control Handle and Power
Switch to retract the Ram. Remove split log pieces, then load the next log.
note:
If difficulty is experienced splitting harder wood, do not keep pressure on the log by trying to force the
Log Splitter. Release the Control Handle after five seconds to retract the ram and avoid damage to the tool.
8. Close the Vent Plug securely when finished or when moving the Log Splitter.
9. To prevent accidents, unplug Log Splitter from its electrical outlet, then clean and store the tool indoors out of children’s reach.
removing a Stuck Log
A log that is too stringy or tough to split completely can become stuck on the Cutting Wedge if the
Wedge becomes embedded in the log and the log doesn’t completely split and separate. If this happens, follow the directions below.
1. Release the Control Handle and Power
Switch to retract the Ram.
2. Unplug the Power Cord.
3. Remove the stuck log from the Cutting
Wedge manually with a pry bar.
WarninG!
Be extremely careful when removing the log as pieces may fly off as they separate from the Wedge. Never attempt to remove a stuck log by using the hydraulic force of the Log Splitter, modifying the Log Splitter, or adding attachments to the Log Splitter. Personal injury could result from log or metal pieces flying out at high speed, or the Log Splitter could become damaged.
4. Do not attempt to re-split a stuck log once it has been removed from the Wedge. Manually split with a maul, or cut with a chainsaw.
Item 63366
For technical questions, please call 1-888-866-5797.
Page 9
Maintenance and Servicing
procedures not specifically explained in this manual must be performed only by a qualified technician.
tO prEVEnt SEriOuS inJury FrOM acciDEntaL OpEratiOn: unplug the tool from its electrical outlet before performing any procedure in this section.
tO prEVEnt SEriOuS inJury FrOM tOOL FaiLurE:
Do not use damaged equipment. if abnormal noise or vibration occurs, have the problem corrected before further use.
cleaning, Maintenance, and Lubrication
1.
BEFOrE EacH uSE,
inspect the general condition of the Log Splitter. Check for:
• loose hardware
• misalignment or binding of moving parts
• cracked or broken parts
• damaged electrical wiring
• leaking hydraulic fluid
(Do not check for leaks during operation.)
• any other condition that may affect its safe operation.
2.
aFtEr uSE,
wipe external surfaces of the tool with clean cloth to remove any tree sap, dirt or hydraulic fluid.
3. Periodically as needed, use a fine-toothed file to smooth out any burrs, nicks or crushed areas and sharpen the cutting edge of the Wedge.
4.
WarninG! if the supply cord of this power tool is damaged, it must be replaced only by a qualified service technician.
Page 10
For technical questions, please call 1-888-866-5797.
Item 63366
replacing Hydraulic Fluid
Change the hydraulic fluid after every 100 hours of use.
1. Unplug the Power Cord.
2. Remove the Rubber Feet from the ends of the Front Leg.
3. Place the Front Leg of the tool in a five quart or greater capacity container. Raise the wheeled end of the Log Splitter using blocks and wheel chocks (not included), tilting the unit to approximately 30 degrees.
Vent plug
Front Leg
Dipstick
Figure c: Draining the Fluid reservoir
4. Remove the Vent Plug, then remove the Dipstick and drain the fluid reservoir. Dispose of the old hydraulic fluid in accordance with local regulations.
5. After the old fluid has been drained, remove the Control Handle. Use the Lift Handle to raise the Log Splitter to a standing position on the wheel end of the unit. Refer to Figure B:
Checking / Adding Fluid on page 8.
6. Refill the fluid reservoir with 3.4 quarts (3.2 liters) of fresh AW32 hydraulic fluid (not included).
note:
If AW32 hydraulic fluid is not available,
Dextron II automatic transmission fluid may be used as a substitute. DO NOT mix Dextron II with AW32 hydraulic fluid—drain reservoir completely if substituting Dextron II.
7. Wipe off the Dipstick and thread it into the fluid reservoir. Remove and check to make sure the fluid level is within the two marks on the Dipstick.
Refer to Figure A: Dipstick on page 8.
8. Replace the Dipstick and tighten securely.
9. Replace the Rubber Feet on the ends of the Front Leg.
10. Use the Lift Handle to return the unit to its normal, horizontal operating position.
11. Plug in the Power Cord.
note: two handed operation required.
12. Press and hold the Power Switch with one hand, then with the other hand, push down and release
Control Handle several times to bleed air.
13. Replace the Vent Plug.
14. Unplug the Power Cord.
Bleeding the Hydraulic System
Trapped air may accumulate in the fluid reservoir causing the Ram to move erratically or not at all, making it necessary to bleed the hydraulic system of excess air. To bleed the hydraulic system:
1. Unplug the Power Cord.
2. Remove the Control Handle before standing the tool upright. Use the Lift Handle to raise the Log Splitter to a standing position on the wheel end of the unit. Refer to Figure B:
Checking / Adding Fluid on page 8.
3. Remove the Vent Plug, then remove the Dipstick.
4. Wipe off the Dipstick and thread it into the fluid reservoir. Remove and check the fluid level; add fluid as needed to bring fluid level within the two marks on the Dipstick. Refer to Figure A: Dipstick on page 8.
5. Replace the Dipstick and tighten securely.
6. Use the Lift Handle to return the unit to its normal, horizontal operating position.
7. Replace Control Handle.
8. Plug in the Power Cord.
note: two handed operation required.
9. Press and hold the Power Switch with one hand, then with the other hand, push down and release
Control Handle several times to bleed air.
10. Replace the Vent Plug.
11. Unplug the Power Cord.
Item 63366
For technical questions, please call 1-888-866-5797.
Page 11
troubleshooting problem possible causes
Tool will not start. 1. Power Cord not connected.
Likely Solutions
1. Check that Power Cord is plugged in.
2. No power at outlet. 2. Check power at outlet. If outlet is unpowered, turn off tool and check circuit breaker.
If breaker is tripped, make sure circuit is right capacity for tool and circuit has no other loads.
3. Tool’s overload protection device has tripped to protect tool from damage.
3. Turn off and unplug tool and allow to cool for
1/2 hour, then restart. If problem is not solved, have qualified technician service tool.
Wood will not split, or splits extremely slowly.
4. Hydraulic fluid level is low.
5. Low maximum pressure rating adjustment was made on the
Maximum Pressure Limiting Screw.
1. Log Splitter not on level ground. Ram vibrates, moves erratically, or does not move.
2. Hydraulic fluid level is low.
3. Excessive air trapped in the hydraulic system.
Fluid leaking from hydraulic system.
4. Internal damage or wear. (Carbon brushes or switch, for example.)
1. Log not positioned properly.
2. The size or hardness of the log exceeds the machine’s capacity.
3. Cutting Wedge is dull.
1. Accumulated air is trapped in hydraulic system while operating.
2. Tool moved with Vent Plug loosened.
3. Dipstick not tightened securely.
4. Hydraulic fittings and/or seals are worn.
4. Have qualified technician service tool.
1. Reposition log. Refer to General
Operating Instructions on page 9.
2. Only split logs within the Log Capacity range shown in Specifications on page 2. Capacity will be limited on hardwood logs and green lumber.
3. Sharpen the Cutting Wedge. Refer to
Maintenance and Servicing on page 10.
4. Check fluid level and add fluid as needed.
5. Have qualified technician adjust maximum pressure rating.
1. Reposition tool so it is level with both ends at same height.
2. Check fluid level and add fluid as needed.
3. Bleed hydraulic system. Refer to Bleeding the Hydraulic System on page 11. Be sure
Vent Plug is loose when operating tool.
1. Loosen Vent Plug before operating tool.
2. Tighten Vent Plug before moving tool.
3. Tighten the Dipstick.
4. Have qualified technician service tool.
Follow all safety precautions whenever diagnosing or servicing the tool.
Disconnect power supply before service.
Page 12
For technical questions, please call 1-888-866-5797.
Item 63366
pLEaSE rEaD tHE FOLLOWinG carEFuLLy
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM
IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR
MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS
QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE
ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY
STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND
LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY
ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS
THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.
record product’s Serial number Here: note:
If product has no serial number, record month and year of purchase instead.
note:
Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts.
Item 63366
For technical questions, please call 1-888-866-5797.
Page 13
parts List and Diagram parts List part Description
1 Cutting Wedge
2 Ram Cap and Shaft
3 Upper Cushion
4 Lower Cushion
5 Ram Base Plate
6 Flat Washer M8 x 1
7 Spring Washer M8 x 2.3
8 Inner Hex Bolt M8 x 15
9 Double-Screw Bolt M10 x 813
10 Cylinder Tube Ø55 x 743
11 Seal Ø55 x 3.1
12 Seal Cover
13 Piston Head
14 O-Ring Ø50 x 3.5
15 Piston Shaft
16 Retracting Spring
17 Nut M14
18 Lock Nut M14
19 Paper Seal Ring
20 O-Ring Ø30 x 2.65
21 Dust Seal
22 Reservoir Cover
23 O-Ring Ø6 x 1
24 Vent Plug M4 x 10
25 Copper Seal Washer M14 x 1
26 Dipstick
27 Hydraulic Valve
28 O-Ring Ø14 x 2.4
29 Flat Washer M10 x 1
30 Spring Washer M10 x 2
31 Nut M10
32 Shield
33 Flat Washer M10 x 2
34 Snap Head Nut M10
35 Torsion Spring
36 Control Handle Bracket
37 Control Handle Lever Ø12.5 X 134
38 Fluid Tube Ø14 / Ø10 x 100 x 1
39 O-Ring Ø18 x 1.9
40 Copper Seal Washer M14 x 1
41 Fluid Tube Screw M14 x 30
42 Inner Hex Bolt M8 x 20
43 Spring Washer M8 x 2.3
Qty
1
4
4
2
2
1
1
2
1
4
4
1
1
1
4
4
4
4
1
1
1
1
1
4
2
2
1
1
1
1
1
1
1
6
6
4
1
1
1
1
1
1
6
part Description
44 Hydraulic Pump
45 O-Ring Ø18 x 1.9
46 Fluid Suction Tube Ø14 / Ø10 x 100 x 1
47 Copper Seal Washer M14 X 1
48 Fluid Tube Screw M14 X 30
49 Fluid Filter
50 Inner Hex Bolt M8 x 35
51 Spring Washer M8 x 2.3
52 Flat Washer M8 x 1
53 Electric Motor
54 Fan
55 Shaft Circlip Ø16
56 Fan Cover Ø162
57 Flat Washer M4 x 1
58 Phillips Head Screw M4 x 10
59 Outlet Box
60 Rubber Gasket
61 Outlet Box Cover
62 Phillips Head Screw M4 x 10
63 Power Switch
64 Capacitor 60uf
65 Power Cord Fastener Nut
66 Power Cord Fastener
67 Power Cord Fastener Bolt
68 Power Cord Sleeve
69 Power Cord
70 Front Leg
71 Phillips Head Screw M6 x 15
72 Flat Washer M6 x 1
73 Spring Washer M6 x 2
74 Nut M6
75 Rubber Foot
76 Lift Handle
77 Phillips Head Screw M6 x 15
78 Guide Plate
79 Flat Washer M8 x 1
80 Spring Washer M8 x 2
81 Inner Hex Bolt M8 x 12
82 Wheel Frame
83 Flat Washer M17 x 2
84 Wheel
85 Flat Washer M10 x 1
86 Lock Nut M10
Qty
1
2
2
2
2
4
4
1
2
1
2
2
4
1
4
8
4
4
1
1
1
1
1
1
1
6
1
1
1
1
3
3
1
4
4
4
1
1
1
1
3
2
1
Page 14
For technical questions, please call 1-888-866-5797.
Item 63366
assembly Diagram
Item 63366
For technical questions, please call 1-888-866-5797.
Page 15
Limited 90 Day Warranty
Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase. This warranty does not apply to damage due directly or indirectly, to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, criminal activity, improper installation, normal wear and tear, or to lack of maintenance. We shall in no event be liable for death, injuries to persons or property, or for incidental, contingent, special or consequential damages arising from the use of our product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation of exclusion may not apply to you. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS.
To take advantage of this warranty, the product or part must be returned to us with transportation charges prepaid. Proof of purchase date and an explanation of the complaint must accompany the merchandise.
If our inspection verifies the defect, we will either repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement. We will return repaired products at our expense, but if we determine there is no defect, or that the defect resulted from causes not within the scope of our warranty, then you must bear the cost of returning the product.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
26541 agoura road • calabasas, ca 91302 • 1-888-866-5797
Download
Advertisement
Key features
5-ton splitting force for effortless log splitting.
12-amp motor for powerful and efficient operation.
Splits logs up to 20.5" long and 10" in diameter.
Compact and portable design for easy storage and transportation.
Built-in log cradle for added stability and safety.
Frequently asked questions
The log splitter can split logs up to 20.5" long and 10" in diameter.
The log splitter generates 5 tons of force.
The log splitter has a 12-amp motor.