advertisement
▼
Scroll to page 2
of 22
GB AristoMig 320 AristoMig U320 AristoMig 450 AristoMig U450 Instruction manual 0459 358 001 GB 041216 Valid for serial no. 310--xxx--xxxx, 445--xxx--xxxx 1 DIRECTIVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3 5 3.1 Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2 Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 5 4 TECHNICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 6 5.1 5.2 5.3 5.4 5.5 5.6 Lifting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Placing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mains power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Terminating resistor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 7 7 8 9 10 6 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 6.1 6.2 6.3 6.4 6.5 Connections and control devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connection of several wire feed units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overheating protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Water flow guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Remote control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 12 12 12 12 7 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 7.1 Filling the coolant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.2 Inspection and cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 13 8 FAULT TRACING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 ORDERING SPARE PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ORDERING NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 13 14 16 17 Rights reserved to alter specifications without notice. TOCe -- 2 -- GB 1 DIRECTIVE DECLARATION OF CONFORMITY ESAB Welding Equipment AB, S--695 81 Laxå, Sweden, gives its unreserved guarantee that welding power source AristoMig 320 / 450 from serial number 310 complies with standard IEC/EN 60974--1, in accordance with the requirements of directive (73/23/EEC) and addendum (93/68/EEC) and with standard EN 50199 in accordance with the requirements of directive (89/336/EEC) and addendum (93/68/EEC). -------------------------------------------------------------------------------------------------------------------------------------- Laxå 2003--06--12 Henry Selenius Vice President ESAB Welding Equipment AB 695 81 LAXÅ SWEDEN 2 Tel: + 46 584 81000 Fax: + 46 584 411924 SAFETY Users of ESAB welding equipment have the ultimate responsibility for ensuring that anyone who works on or near the equipment observes all the relevant safety precautions. Safety precautions must meet the requirements that apply to this type of welding equipment. The following recommendations should be observed in addition to the standard regulations that apply to the workplace. All work must be carried out by trained personnel well--acquainted with the operation of the welding equipment. Incorrect operation of the equipment may lead to hazardous situations which can result in injury to the operator and damage to the equipment. 1. Anyone who uses the welding equipment must be familiar with: S its operation S location of emergency stops S its function S relevant safety precautions S welding 2. The operator must ensure that: S no unauthorized person is stationed within the working area of the equipment when it is started up. S no--one is unprotected when the arc is struck 3. The workplace must: S be suitable for the purpose S be free from drafts 4. Personal safety equipment S Always wear recommended personal safety equipment, such as safety glasses, flame--proof clothing, safety gloves. S Do not wear loose--fitting items, such as scarves, bracelets, rings, etc., which could become trapped or cause burns. 5. General precautions S Make sure the return cable is connected securely. S Work on high voltage equipment may only be carried out by a qualified electrician. S Appropriate fire extinquishing equipment must be clearly marked and close at hand. S Lubrication and maintenance must not be carried out on the equipment during operation. bu18d1e -- 3 -- GB WARNING ARC WELDING AND CUTTING CAN BE INJURIOUS TO YOURSELF AND OTHERS. TAKE PRECAUTIONS WHEN WELDING. ASK FOR YOUR EMPLOYER’S SAFETY PRACTICES WHICH SHOULD BE BASED ON MANUFACTURERS’ HAZARD DATA. ELECTRIC SHOCK -- Can kill S Install and earth the welding unit in accordance with applicable standards. S Do not touch live electrical parts or electrodes with bare skin, wet gloves or wet clothing. S Insulate yourself from earth and the workpiece. S Ensure your working stance is safe. FUMES AND GASES -- Can be dangerous to health S Keep your head out of the fumes. S Use ventilation, extraction at the arc, or both, to take fumes and gases away from your breathing zone and the general area. ARC RAYS -- Can injure eyes and burn skin. S Protect your eyes and body. Use the correct welding screen and filter lens and wear protective clothing. S Protect bystanders with suitable screens or curtains. FIRE HAZARD S Sparks (spatter) can cause fire. Make sure therefore that there are no inflammable materials nearby. NOISE -- Excessive noise can damage hearing S Protect your ears. Use earmuffs or other hearing protection. S Warn bystanders of the risk. MALFUNCTION -- Call for expert assistance in the event of malfunction. READ AND UNDERSTAND THE INSTRUCTION MANUAL BEFORE INSTALLING OR OPERATING. PROTECT YOURSELF AND OTHERS! ESAB can provide you with all necessary welding protection and accessories. WARNING! Read and understand the instruction manual before installing or operating. WARNING! Do not use the power source for thawing frozen pipes. This product is solely intended for arc welding. bu18d1e -- 4 -- GB 3 INTRODUCTION The AristoMig 320 and AristoMig 450 power sources are intended for MMA (welding with coated electrodes), MIG/MAG welding, TIG welding and carbon--arc gouging. AristoMig is used in combination with the AristoPendant U8 control unit and/or the AristoFeed 30--4 or AristoFeed 48--4 wire feed unit. ESAB’s accessories for the product can be found on page 17. 3.1 Equipment AristoMig is supplied with terminating resistor, mains cable, guide pin, gas cylinder shelf, return cable and instruction manual. 3.2 Settings All settings are made using the control unit AristoPendant U8 or wire feed unit with MMC. Operation -- see separate instruction manuals. 4 TECHNICAL DATA Mains voltage Maximum permissible load at 100% duty cycle 60% duty cycle Setting range MIG/MAG MMA TIG Open--circuit voltage MIG/MAG MMA TIG Open--circuit output with water Efficiency at maximum current MIG/MAG MMA TIG Power factor at maximum current MIG/MAG MMA TIG Enclosure class Weight with cooling unit Dimensions, l x w x h Application class bu18d1e AristoMig 320/320w/U320w 400V 3~50/60 Hz AristoMig 320/320w/U320w 230/400/500V 3~50Hz 208/230/460/475V 3~60 Hz 270A / 30.8V 320A / 32.8V 270A / 30.8V 320A / 32.8V 15A/ 15V(8V)--320A/30V 16A / 20V -- 320A/32.8V 4A / 10V -- 320A/22.7V 30A/15V(8V)--320A/30V 10A / 20V -- 320A /32.8V 10A / 10V -- 320A / 22.7V 65 -- 80 V 50 --60 V 50 --60 V 180 -- 210 W 380 -- 470 W 65 -- 80 V 50 --60 V 50 --60 V 180 -- 210 W 380 -- 470 W 82% 84.5% 82% 82% 84.5% 84.5% 0.85 0.85 0.80 IP 23 96 kg 110 kg 910 x 642 x 835 mm 0.85 0.85 0.80 IP 23 143 kg 157 kg 910 x 642 x 835 mm -- 5 -- GB Mains voltage Maximum permissible load at 100% duty cycle 60% duty cycle 45% duty cycle Setting range MIG/MAG MMA TIG Open--circuit voltage MIG/MAG MMA TIG Open--circuit output with cooling unit Efficiency at maximum current MIG/MAG MMA TIG Power factor at maximum current MIG/MAG MMA TIG Enclosure class Weight with cooling unit Dimensions, l x w x h Application class AristoMig 450/450w/U450w 400V 3~50/60 Hz AristoMig 450/450w/U450w 230/400/500V 3~50Hz 208/230/460/475V 3~60 Hz 360A / 34.4V 425A / 37V 450A / 38V 360A / 34.4V 425A / 37V 450A / 38V 15A/ 15V (8V)--450A/ 36.5V 16A / 20V -- 450A / 38V 4A / 10V -- 450A / 28V 30A/ 15V (8V)--450A/ 36.5V 10A / 20V -- 450A / 38V 10A / 10V -- 450A / 28V 65 -- 80 V 50 --60 V 50 --60 V 180 -- 210 W 380 -- 470 W 65 -- 80 V 50 --60 V 50 --60 V 180 -- 210 W 380 -- 470 W 82% 83% 83% 82% 83% 83% 0.92 0.92 0.90 IP 23 96 kg 110 kg 910 x 642 x 835 mm 0.92 0.92 0.90 IP 23 143 kg 157 kg 910 x 642 x 835 mm Maximum number of water--cooled welding guns/torches that may be connected: two MIG welding guns or one TIG torch and one MIG welding gun Duty cycle The duty cycle refers to the time as a percentage of a ten--minute period that you can weld at a certain load without overloading. Enclosure class The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid objects or water. Equipment marked IP23 is designed for indoor and outdoor use. Application class The symbol indicates that the power source is designed for use in areas with increased electrical hazard. 5 INSTALLATION The installation must be executed by a professional. WARNING! This product is intended for industrial use. In a domestic environment this product may cause radio interference. It is the user’s responsibility to take adequate precautions. bu18d1e -- 6 -- GB 5.1 Lifting instructions Lifting instructions Straps must be used when lifting the power source. The handle is only intended for pulling it. 5.2 Placing WARNING - TIPPING RISK! Fasten the equipment -- particularly if the ground is uneven or sloping. IMPORTANT! Place the equipment in an appropriate position and ensure that the power source is not covered or placed so that cooling is obstructed. 5.3 bu18d1e Installation -- 7 -- GB 5.4 Mains power supply Make sure that the welding power source is connected to the correct supply voltage and that it is protected by the correct fuse rating. A protective earth connection must be made in accordance with regulations. Rating plate with supply connection data Recommended fuse sizes and minimum cable areas AristoMig 320 3~50 Hz 3~50 Hz 3~50 Hz 3~60 Hz 3~60 Hz 3~60 Hz 3~60 Hz Mains voltage V 230 400 500 208 230 460 475 Current A 100% 60% 27 37 16 21 13 15 30 38 27 34.5 13.5 17 13 16.5 Mains cable area 4G10 4G4 4G4 4G10 4G10 4G4 4G4 Fuse anti--surge A 25 16 16 35 25 16 16 AristoMig 450 Mains voltage V 3~50 Hz 230 3~50 Hz 400 3~50 Hz 500 3~60 Hz 208 3~60 Hz 230 3~60 Hz 460 3~60 Hz 475 Current A 100% 40 24.5 18.5 45 41 20 19.5 60% 51 30.5 23 57.5 51.5 25 24.5 45% 55.5 34 25 62 56.5 27.5 26.5 Mains cable area 4G10 4G4 4G4 4G10 4G10 4G4 4G4 Fuse anti--surge A 50 20 20 50 50 20 20 Note! The mains cable areas and fuse sizes as shown above are in accordance with Swedish regulations. Use the welding power source in accordance with the relevant national regulations. bu18d1e -- 8 -- GB 5.5 bu18d1e Electrical installation -- 9 -- GB 5.6 Terminating resistor The ends of the CAN bus must be fitted with terminating resistors to avoid communication interference. One end of the CAN bus is on the control unit or wire feed unit MMC, this has an in--built terminating resistor. The other end must be fitted with the terminating resistor, as shown in the figure. Depending on the type of connection the resistor is connected as follows: 1. Control panel connected to the wire feed unit. The terminating resistor is connected at the rear of the power source. (Connected like this on delivery). 2. Control unit connected to the power source. The terminating resistor is connected to the front of the wire feed unit. bu18d1e -- 10 -- GB 6 OPERATION General safety regulations for the handling of the equipment can be found on page 3. Read through before you start using the equipment! Note! Make sure the connection cable (max 8 m) between the power source, feeding unit and return cable (max 8 m) are not coiled up when pulsing. 6.1 Connections and control devices TIG, Central connection MMA, MIG/MAG TIG, OKC--connection 1 Cooling water filler 11 OKC--connection TIG--torch. 2 Orange indicating lamp, overheating 12 Gas connection to TIG--torch 3 White indicating lamp -- power supply 13 Connection for start signal from TIG--torch 4 Mains voltage switch 1 / 0 14 Gas hose connector 5 Cooling unit switch (AristoMig 320w and AristoMig 450w) 15 Connection for welding current cable (+) to wire feed unit. 6 Connection for cooling water from the TIG torch -- RED 16 MCB (miniature circuit breaker) 42V to wire feed unit. 7 Connection for cooling water to TIG--torch -- BLUE 17/18 8 Central TIG--torch connection. 19 Connection for cooling water from the wire feed unit -- RED 9 Connection (--) for the return cable for MMA and MIG/MAG or for the welding current cable when TIG welding 20 Connection for cooling water to the wire feed unit -- BLUE 10 Connection (+) for the welding current cable for MMA welding or for the return cable when TIG welding bu18d1e -- 11 -- Connection for AristoPendant U8 control unit, for control cable to the wire feed unit, for terminating resistor or for the remote control adapter. GB 6.2 Connection of several wire feed units The wire feed unit AristoFeed 30--4 or AristoFeed 48--4 with control panel (M0) and the AristoPendant U8 control unit are to be used when connecting several wire feed units. Please contact authorised ESAB service personnel when connecting several wire feed units. 6.3 Overheating protection The power source is fan cooled and is fitted with a thermal cut--out that trips when the temperature is too high, this prevents overheating. Resetting takes place automatically once the power source has cooled. When this occurs the welding current is interrupted and the orange indicating lamp on the front of the power source comes on. 6.4 Water flow guard The water flow guard blocks the power source if the cooling water stops. When this occurs the welding current is interrupted and an alarm is shown on the control unit. The water flow guard is an accessory. 6.5 Remote control unit The program version in AristoPendant U8 should be 1.20 or higher. Aristo mchines with intergral control panels should have program version 1.21 or higher, in order for the remote control to function correctly. When the remote control unit is connected, the power source and wire feed unit are in remote control mode; the buttons and knobs are blocked. The functions can only be adjusted via the remote unit. If the remote control unit is not to be used, the remote control unit must be disconnected from the power source / wire feed unit, as otherwise it will remain in remote control mode. When a remote control unit can set the voltage, the function will change to set the current with MMA welding. For more information about the operation of the remote control unit, see the instruction manuals for the control unit/MMC. 7 MAINTENANCE Regular maintenance is important for safe, reliable operation. Note! All guarantee undertakings from the supplier cease to apply if the customer himself attempts any work in the product during the guarantee period in order to rectify any faults. Only those persons who have appropriate electrical knowledge (authorized personnel) may remove the safety plates to connect or carry out service, maintenance or repair work on welding equipment. bu18d1e -- 12 -- GB 7.1 Filling the coolant We recommend a 50/50 % mixture of water and ethylene glycol. 7.2 Inspection and cleaning Check regularly that the power source unit is not clogged with dirt. How often and which cleaning methods apply depend on: the welding process, arc times, placement, and the surrounding environment. It is normally sufficient to blow down the power source with compressed air (reduced pressure) once a year. 8 FAULT TRACING Try these recommended checks and inspections before sending for an authorised service technician. Type of fault No arc. Action S S S S The welding current is interrupted during welding. S S Check that the mains power supply switch is turned on. Check that the welding current supply and return cables are correctly connected. Check that the correct current value is set. Check to see whether the MCB has tripped. Check whether the thermal cut--out has tripped (indicated by the orange lamp on the front panel). Check the main power supply fuses. The thermal cut--out trips frequently. S Make sure that you are not exceeding the rated data for the power source (i.e. that the unit is not being overloaded). Poor welding performance. S Check that the welding current supply and return cables are correctly connected. Check that the correct current value is set. Check that the correct electrodes are being used. Check the main power supply fuses S S S 9 ORDERING SPARE PARTS Repair and electrical work should be performed by an authorized ESAB serviceman. Use only ESAB original spare and wear parts. AristoMig 320/450 is designed and tested in accordance with the international and European standards IEC/EN 60974--1 and EN 50199. It is the obligation of the service unit which has carried out the service or repair work to make sure that the product still conforms to the said standard. Spare parts may be ordered through your nearest ESAB dealer, see the last page of this publication. bu18d1e -- 13 -- Diagram bu18e11a -- 14 -- bu18e11a -- 15 -- AristoMig 320, AristoMig 450 Ordering number Ordering no. Denomination 0459 348 880 AristoMig 320 0459 348 882 AristoMig 320 0459 348 881 AristoMig 320w 0459 348 883 AristoMig 320w 0459 348 884 AristoMig U320w 0459 348 885 AristoMig U320w 0459 348 886 AristoMig U320w 0459 348 887 AristoMig U320w 0459 349 880 AristoMig 450 0459 349 881 AristoMig 450w 0459 349 882 AristoMig 450 0459 349 883 AristoMig 450w 0459 349 884 AristoMig U450w 0459 349 885 AristoMig U450w 0459 349 886 AristoMig U450w 0459 349 887 AristoMig U450w 0459 358 990 AristoMig 320 / 450 bu18o11a Mains voltage Notes 400 V 3~ 50/60 Hz MMA, MIG/MAG 400 V 3~ 50/60 Hz MMA, MIG/MAG 400 V 3~ 50/60 Hz MMA, MIG/MAG, TIG with OKC connection 208/230/400/460/475/500 V 3~ 50/60 Hz MMA, MIG/MAG, TIG with OKC connection 400 V 3~ 50/60 Hz MMA, MIG/MAG 208/230/400/460/475/500 V 3~ 50/60 Hz MMA, MIG/MAG 400 V 3~ 50/60 Hz MMA, MIG/MAG, TIG with OKC connection 208/230/400/460/475/500 V 3~ 50/60 Hz MMA, MIG/MAG, TIG with OKC connection 208/230/400/460/475/500 V 3~ 50/60 Hz MMA, MIG/MAG 208/230/400/460/475/500 V 3~ 50/60 Hz MMA, MIG/MAG 400 V 3~ 50/60 Hz MMA, MIG/MAG, TIG with central connection 208/230/400/460/475/500 V 3~ 50/60 Hz MMA, MIG/MAG, TIG with central connection 400 V 3~ 50/60 Hz MMA, MIG/MAG 208/230/400/460/475/500 V 3~ 50/60 Hz MMA, MIG/MAG 400 V 3~ 50/60 Hz MMA, MIG/MAG, TIG with central connection 208/230/400/460/475/500 V 3~ 50/60 Hz MMA, MIG/MAG, TIG with central connection -- 16 -- Spare parts list Edition 041216 AristoMig 320, AristoMig 450 Accessories Trolley . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0457 221 881 Guide pin (delivered with the AristoMig) . . . . 0455 834 880 Stabilization kit . . . . . . . . . . . . . . . . . . . . . . . . . 0457 950 880 Guide pin 0156 654 896 is included clud1ae1 -- 17 -- Edition 041216 AristoMig 320, AristoMig 450 AristoSelector 320/450 stabilization kit included . . . . . . . . . . . . . . . . . . . 0457 073 881 Gasket kit for water pump . . . . . . . . . . . . . . . . . 0459 699 880 Remote control adapter RA12 12 pole . . . . 0459 491 910 For analogue remote controls to CAN based equipment. Remote control unit MTA1 CAN . . . . . . . . . . 0459 491 880 MIG/MAG: wire feed speed and voltage MMA: current and arc force TIG: current, pulse and background current clud1ae1 -- 18 -- Edition 041216 AristoMig 320, AristoMig 450 Remote control unit M1 10Prog CAN . . . . . . 0459 491 882 Choice of on of 10 programs MIG/MAG: voltage deviation TIG and MMA: current deviation Remote control unit AT1 CAN . . . . . . . . . . . . 0459 491 883 MMA and TIG: current Remote control unit AT1 CF CAN . . . . . . . . . 0459 491 884 MMA and TIG: rough and fine setting of current. Remote control cable 4 pole -- 12 pole 5m .................................... 10 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.25 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0459 554 880 0459 554 881 0459 554 882 0459 554 883 0459 554 884 Connection set 1.7 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5m .................................... 10 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connection set water 0456 528 880 0456 528 890 0456 528 881 0456 528 882 0456 528 883 0456 528 884 1.7 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5m .................................... 10 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0456 528 885 0456 528 895 0456 528 886 0456 528 887 0456 528 888 0456 528 889 Return cable 5 m 70 mm2 . . . . . . . . . . . . . . . . 0156 743 881 clud1ae1 -- 19 -- Edition 041216 AristoMig 320, AristoMig 450 Water flow guard 0.7 l/min . . . . . . . . . . . . . . . . 0456 855 880 Connection set for connection of two wire feed units . . . . . . . . 0459 546 880 clud1ae1 -- 20 -- Edition 041216 ESAB subsidiaries and representative offices Europe AUSTRIA ESAB Ges.m.b.H Vienna--Liesing Tel: +43 1 888 25 11 Fax: +43 1 888 25 11 85 BELGIUM S.A. ESAB N.V. Brussels Tel: +32 2 745 11 00 Fax: +32 2 726 80 05 THE CZECH REPUBLIC ESAB VAMBERK s.r.o. Prague Tel: +420 2 819 40 885 Fax: +420 2 819 40 120 DENMARK Aktieselskabet ESAB Copenhagen--Valby Tel: +45 36 30 01 11 Fax: +45 36 30 40 03 FINLAND ESAB Oy Helsinki Tel: +358 9 547 761 Fax: +358 9 547 77 71 FRANCE ESAB France S.A. Cergy Pontoise Tel: +33 1 30 75 55 00 Fax: +33 1 30 75 55 24 GERMANY ESAB GmbH Solingen Tel: +49 212 298 0 Fax: +49 212 298 218 GREAT BRITAIN ESAB Group (UK) Ltd Waltham Cross Tel: +44 1992 76 85 15 Fax: +44 1992 71 58 03 ESAB Automation Ltd Andover Tel: +44 1264 33 22 33 Fax: +44 1264 33 20 74 HUNGARY ESAB Kft Budapest Tel: +36 1 20 44 182 Fax: +36 1 20 44 186 ITALY ESAB Saldatura S.p.A. Mesero (Mi) Tel: +39 02 97 96 81 Fax: +39 02 97 28 91 81 THE NETHERLANDS ESAB Nederland B.V. Utrecht Tel: +31 30 2485 377 Fax: +31 30 2485 260 NORWAY AS ESAB Larvik Tel: +47 33 12 10 00 Fax: +47 33 11 52 03 POLAND ESAB Sp.zo.o. Katowice Tel: +48 32 35 111 05 Fax: +48 32 35 111 20 PORTUGAL ESAB Lda Lisbon Tel: +351 8 310 960 Fax: +351 1 859 1277 SLOVAKIA ESAB Slovakia s.r.o. Bratislava Tel: +421 7 44 88 24 26 Fax: +421 7 44 88 87 41 SPAIN ESAB Ibérica S.A. Alcalá de Henares (MADRID) Tel: +34 91 878 3600 Fax: +34 91 802 3461 SWEDEN ESAB Sverige AB Gothenburg Tel: +46 31 50 95 00 Fax: +46 31 50 92 22 ESAB International AB Gothenburg Tel: +46 31 50 90 00 Fax: +46 31 50 93 60 SWITZERLAND ESAB AG Dietikon Tel: +41 1 741 25 25 Fax: +41 1 740 30 55 North and South America ARGENTINA CONARCO Buenos Aires Tel: +54 11 4 753 4039 Fax: +54 11 4 753 6313 Asia/Pacific CHINA Shanghai ESAB A/P Shanghai Tel: +86 21 5308 9922 Fax: +86 21 6566 6622 INDIA ESAB India Ltd Calcutta Tel: +91 33 478 45 17 Fax: +91 33 468 18 80 INDONESIA P.T. ESABindo Pratama Jakarta Tel: +62 21 460 0188 Fax: +62 21 461 2929 JAPAN ESAB Japan Tokyo Tel: +81 3 5296 7371 Fax: +81 3 5296 8080 MALAYSIA ESAB (Malaysia) Snd Bhd Shah Alam Selangor Tel: +60 3 5511 3615 Fax: +60 3 5512 3552 SINGAPORE ESAB Asia/Pacific Pte Ltd Singapore Tel: +65 6861 43 22 Fax: +65 6861 31 95 Representative offices BULGARIA ESAB Representative Office Sofia Tel/Fax: +359 2 974 42 88 EGYPT ESAB Egypt Dokki--Cairo Tel: +20 2 390 96 69 Fax: +20 2 393 32 13 ROMANIA ESAB Representative Office Bucharest Tel/Fax: +40 1 322 36 74 RUSSIA-- CIS ESAB Representative Office Moscow Tel: +7 095 937 98 20 Fax: +7 095 937 95 80 ESAB Representative Office St Petersburg Tel: +7 812 325 43 62 Fax: +7 812 325 66 85 Distributors For addresses and phone numbers to our distributors in other countries, please visit our home page www.esab.com SOUTH KOREA ESAB SeAH Corporation Kyungnam Tel: +82 55 269 8170 Fax: +82 55 289 8864 UNITED ARAB EMIRATES ESAB Middle East Dubai Tel: +971 4 338 88 29 Fax: +971 4 338 87 29 BRAZIL ESAB S.A. Contagem--MG Tel: +55 31 2191 4333 Fax: +55 31 2191 4440 CANADA ESAB Group Canada Inc. Missisauga, Ontario Tel: +1 905 670 02 20 Fax: +1 905 670 48 79 MEXICO ESAB Mexico S.A. Monterrey Tel: +52 8 350 5959 Fax: +52 8 350 7554 USA ESAB Welding & Cutting Products Florence, SC Tel: +1 843 669 44 11 Fax: +1 843 664 57 48 ESAB AB SE-- 695 81 LAXÅ SWEDEN Phone +46 584 81 000 www.esab.com 041216
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project