DMD Handling Specification
Application Report
Literature Number: DLPA019A
June 2010 – Revised November 2019
Contents
1
2
3
PURPOSE ........................................................................................................................... 3
SCOPE ................................................................................................................................ 3
LIMITS & DEFINITIONS: ........................................................................................................ 3
3.1
DLP® Products Electrostatic Discharge Immunity Levels .......................................................... 3
3.2
Electrostatic Discharge Definitions ..................................................................................... 3
3.3
DMD Handling Definitions ............................................................................................... 3
4
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS .............................................................. 4
5
DMD HANDLING PRECAUTIONS: ........................................................................................... 5
Appendix A IONIZER ‘QUICK CHECK’............................................................................................. 7
A.1
IONIZER ‘QUICK CHECK’............................................................................................. 7
1
Related Documentation......................................................................................................... 8
2
Table of Contents
DLPA019A – June 2010 – Revised November 2019
Submit Documentation Feedback
Copyright © 2010–2019, Texas Instruments Incorporated
Application Report
DLPA019A – June 2010 – Revised November 2019
DMD Handling Specification
1
PURPOSE
•
•
•
2
Define the minimum requirements for DMD Handling.
Establish precautions to protect the DMD from Electrostatic Discharge (ESD).
Establish precautions to protect the DMD’s glass and electrical contacts.
SCOPE
•
•
This specification applies to all operations in which DMDs are used.
Reference EIA-JESD 625A (Requirements for Handling Electrostatic Discharge-Sensitive (ESD)
Devices for additional information.
3
LIMITS & DEFINITIONS:
3.1
DLP® Products Electrostatic Discharge Immunity Levels
All external signals on a DMD are protected from damage by electrostatic discharge, according to
JESD22-A114-B Electrostatic Discharge (ESD) Sensitivity Testing Human Body Model (HBM) to the levels
indicated in the Handling Ratings table of the DMD data sheet.
3.2
Electrostatic Discharge Definitions
Anti-Static Material— Material that minimizes the generation of static charge when rubbed against itself,
or when separated from itself or other similar material.
Conductive Material— Material having a surface resistivity of less than 10 × 105Ω per square inch
Electrostatic Discharge (ESD)— A transfer of electrostatic charge between bodies at different
electrostatic potentials caused by direct contact or induced by an electrostatic field.
ESD Ground— Use either an earth ground or a third-wire ground.
Insulative Material— Material having a surface resistivity equal to or greater than 10 × 1012Ω per square
inch.
Ionizer— Equipment that generates positive and negative ions, either by electrostatic means or by means
of a radioactive energy source (such as polonium 210), and distributes a layer of ionized air over a
work area to neutralize static charges.
Static-Dissipative Material— Material having surface resistivities between 10 × 105Ω and 10 × 1012Ω per
square inch.
3.3
DMD Handling Definitions
DMD Window— The window is the glass that covers the mirrors in the DMD. This surface of the DMD is
referred to as the front of the DMD.
DMD Pins (Electrical Contact)— The pins are the electrical connection for the DMD. The electrical
connections are on the back of the DMD. Care should be taken not to bend or break the pins.
DLPA019A – June 2010 – Revised November 2019
Submit Documentation Feedback
Copyright © 2010–2019, Texas Instruments Incorporated
DMD Handling Specification
3
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS
www.ti.com
DMD Pads and Connector (Electrical Contacts)— In the case of smaller DMD packages without pins,
the pads (for TI internal test use) and connector (for end product use) are the electrical connection
for the DMD. These electrical connections are on the back of the DMD.
4
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS
•
•
•
4
General requirements
– All equipment, tools, fixtures and handling aids used for processing, handling, or storing of ESDSensitive (ESDS) products shall be made from conductive or static-dissipative material. Where
conductive or static-dissipative material can not be used, antistatic solution can be used as a
means to reduce static charge generation. During application of any antistatic solutions, the
guidelines below must be followed:
• Use approved antistatic solutions only. They must be free of reactive elements (such as
chlorine, phosphorus, sodium, and so forth). Antistatic solutions must not contaminate ESDS
devices.
• The solution must be re-applied to insure that the equipment, fixtures, tools, and so forth,
generate less than ±100 V potential when rubbed vigorously with any insulative material (the
frequency of once/day is recommended).
• Antistatic solutions must not be applied when devices are directly exposed to spray mists.
– All flooring in the manufacturing area shall be conductive or static-dissipative.
– All conductive or static-dissipative storage racks, fixtures, and so forth shall be connected to ESD
ground through a 1 MΩ ± 10% resistor.
– All grounding for work surfaces, racks, equipment, and so forth shall meet all local safety codes and
requirements.
– Any temporary connection used to ground any work surface, rack, equipment, and so forth shall be
of a snap or plug-and-socket type.
– All electrical equipment used at the work station shall be hard grounded (third-wire grounded).
Small hand tools such as tweezers may be grounded through the operators.
– Any electrical equipment located on the work surface shall be hard grounded (third-wire grounded)
and shall also be isolated from the work surface.
– It is strongly recommended that a qualified safety engineer perform a safety review of all new or
modified ESD ground connections prior to their initial use.
– Operators who are handling DMD devices shall wear a Wrist Strap as described below and a Heel
Strap as described below.
Ionizers
– Forced-air, table-mounted ionizers shall be located so that devices are:
• within a 1.3 meter (4-foot) arc measured by a vertical line from the face of the ionizer and 45
degrees on either side of this line, and
• at least 0.3 meter (1-foot) away from the ionizer.
– All ionizing units shall be located in a position to limit charge-buildup in the DMD handling area of
the work station to ±100 volts.
– It is recommended that all ionizers be approved by a qualified safety engineer prior to
implementation.
– The following checks on the ionizers (work station ionizers only) shall be performed:
• On a monthly basis, check for proper operation of the ionizers with the ‘quick check’ procedure
(or equivalent) described in Appendix A.
• On a semi-annual basis, check, as a minimum, for proper ionization output, ionization balance,
and electrode cleanliness according to manufacturer’s instructions. Record of the checks shall
be maintained.
Work Stations
– Wrist straps shall be connected to ESD ground through a 1MΩ ± 10% resistor. A workstation
monitor which constantly monitors the resistance of the workstation, operator, and wiring
connections and alarms when connections are broken or missing is required at all work stations
DMD Handling Specification
DLPA019A – June 2010 – Revised November 2019
Submit Documentation Feedback
Copyright © 2010–2019, Texas Instruments Incorporated
DMD HANDLING PRECAUTIONS:
www.ti.com
•
•
5
where ESDS materials are being handled. (Example of Monitor is the 3M Workstation Monitor
model 720) Static-dissipative work surfaces, and conductive or static-dissipative floor mats shall be
connected to ESD ground through a 1 MΩ ± 10% resistor.
– An ionizer shall be used at each work station. There shall be no static-generating materials at the
work station, and a conductive static-dissipative or antistatic smock shall be worn by the operator. A
ceiling ionizer is sufficient for the work station provided that there is no obstruction between it and
the work surface where ESD sensitive materials are being handled (such as under a hood).
Wrist Straps
– Wrist straps shall be worn when handling DMDs.
– Wrist straps shall be connected to an ESD monitor.
– When the wrist strap is connected to the static-dissipative mat, it shall be connected to the same
metallic button or the contactor used to ground the mat. This may result in the wrist strap being 2
MΩ ± 10% above ground, which is acceptable.
– Wrist strap shall be worn snugly around the wrist to ensure continuous electrical contact with bare
skin.
– Wrist straps shall be checked daily to ensure that proper grounding is maintained.
Heel Straps or Conductive Shoes or Conductive Slippers
– Conductive shoes, slippers or heel straps shall be worn when handling DMDs.
– Heel or toe strap shall solidly contact conductive flooring. The contact ribbon shall make electrical
contact with human body.
– Heel straps or conductive shoes shall be checked daily to ensure that proper grounding is
maintained.
DMD HANDLING PRECAUTIONS:
•
•
•
•
•
•
•
•
The DMD's glass has a higher profile then the DMD’s body. Extra caution should be observed when
handling the DMD to ensure the glass is not scratched. Never place a DMD face down (glass down) on
any surface because scratches in the glass may occur.
The S2xx and S3xx DMD's are very small and the glass window is entirely exposed. Picking up parts
with fingers can easily lead to touching or contaminating the DMD window even when wearing finger
cots. It is recommended that plastic tip tweezers, such as TDI International 2AXCPR-SA or TDI
International 2AXCFR-SA, or equivalent be used to pick up these DMD's.
All equipment, tools, and so forth used shall meet the requirements outlined in this document.
Do not place tape, labels, or marking on the DMD glass or on the back electrical pin contacts of the
DMD.
All manual processing or handling of DMDs shall be performed at static-free work stations.
Before using a static-free work station, the operator shall:
– Check that the wrist strap is connected correctly.
– If work station ionizer is used, check that it is switched on and properly positioned to aim at the
devices and operator’s hands.
An antistatic, static-dissipative, or conductive smock must be worn where ionizer is not present. Longsleeved garments must be completely covered by the smock, except at the neck area.
DMDs shall be stored and transported between static-free work stations in an enclosed conductive
container. Do not transport the DMD device without such a container, even for short distances. The
DMD container must keep the device stationary during transport. The container can only be opened at
a static-free work station when the container is in contact with a properly grounded static-dissipative
surface. The surface must be sturdy and as close to the process as possible.
– Always hold the DMD containers with two hands away from the body and with a firm grip. Handle
the carrier gently.
– Do not place anything inside the container with the devices except for ESD approved packaging
material.
– Do not allow any object to come in contact with the glass of the DMD device.
DLPA019A – June 2010 – Revised November 2019
Submit Documentation Feedback
Copyright © 2010–2019, Texas Instruments Incorporated
DMD Handling Specification
5
DMD HANDLING PRECAUTIONS:
•
•
•
•
•
•
6
www.ti.com
– Do not write on top of a DMD container full of devices.
– Use clean DMD containers only.
– Any operation performed with DMDs should be at a static free work station.
Clean antistatic or conductive gloves or finger cots must be worn at all times when handling DMD
devices. Replace gloves and finger cots when they are dirty or damaged.
Extreme caution must be used when handling DMD devices to ensure that the glass area is not
touched or scratched. Handle the DMD device by the package edges only.
Remove the DMD device from the carrier gently. When putting the DMD into the carrier, use caution.
Do not drop the DMDs into the carrier. Ensure that the DMDs are well-seated in the carrier.
Touching of pins or contacts must be avoided. Handle the DMD device by the package edges only.
Cleaning the window of the DMD device must only be performed per DLP® DMD Glass Cleaning
Procedure - DLPA025.
Clothing other than approved conductive or static-dissipative garments shall not be allowed within 150
mm (12 inches) of any DMD which is not protected in an appropriate conductive container.
It is the responsibility of the operator and the area supervisor to ensure that the static- free work area
is clear of unnecessary static hazards. All work-related items, including log book, tools, and device
containers must be approved for use at the static- free work station.
DMD Handling Specification
DLPA019A – June 2010 – Revised November 2019
Submit Documentation Feedback
Copyright © 2010–2019, Texas Instruments Incorporated
Appendix A
DLPA019A – June 2010 – Revised November 2019
IONIZER ‘QUICK CHECK’
A.1
IONIZER ‘QUICK CHECK’
A. Equipment / Materials
a. Electrostatic voltmeter
b. Sticky plastic tape (for example, transparent adhesive tape)
B. Assure that the ionizer to be checked is turned off and that all other ionizers in the area are either
turned off or positioned so that they do not affect the ionizer being checked.
C. Prepare two (2) pieces of tape as follows:
a. Cut two pieces of tape approximately 10 cm (4 inches) in length.
b. Fold over each end of one piece of tape (sticky side to sticky side), approximately 1 cm (0.5 inch)
to create pull tabs for step d).
c. Stick the two pieces of tape together (sticky side of tabbed tape to the non-sticky side of nontabbed tape).
d. Separate the two pieces of tape using a fast, even pull, thereby creating one piece of tape charged
to approximately +1000 to +2000 volts and the other charged to approximately –1000 to –2000
volts.
D. Place the positively charged piece of tape 0.3 – 0.5 meter (1 – 1.5 feet) directly in front of the ionizer to
be checked. Turn on the ionizer for 30 – 35 seconds, and then turn it off.
E. Measure the electrostatic charge on the tape. Acceptable voltage level is 0 ± 50 volts.
F. Repeat the steps in paragraph 4 through 5, except use the negatively charged piece of tape.
DLPA019A – June 2010 – Revised November 2019
Submit Documentation Feedback
Copyright © 2010–2019, Texas Instruments Incorporated
DMD Handling Specification
7
Application Report
DLPA019A – June 2010 – Revised November 2019
Related Documentation
1
Related Documentation
Table 1. Related Documentation
Document
8
TI Literature Number
DLP® DMD Glass Handling Procedure
DLPA025
DLP2010NIR 0.2 WVGA Series Near-Infrared data sheet
DLPS059
DLP3000 0.3 WVGA Series 220 DMD data sheet
DLPS022
DLP4500 0.45 WXGA DMD data sheet
DLPS028
DLP4500NIR 0.45 WXGA Near-Infrared DMD data sheet
DLPS032
DLP5500 0.55 XGA DMD Series 450 DMD data sheet
DLPS013
DLP6500FYE 0.65 1080p DMD data sheet
DLPS053
DLP6500FLQ 0.65 1080p MVSP Type-A DMD data sheet
DLPS040
DLP7000 0.7 XGA Type-A DMD data sheet
DLPS026
DLP7000UV 0.7 XGA UV Type-A DMD data sheet
DLPS061
DLP9000 Family of 0.9 WQXGA Type-A DMD data sheet
DLPS036
DLP9500 0.95 1080p Type-A DMD data sheet
DLPS025
DLP9500UV 0.95 1080p UV Type-A DMD data sheet
DLPS033
DMD Handling Specification
DLPA019A – June 2010 – Revised November 2019
Submit Documentation Feedback
Copyright © 2010–2019, Texas Instruments Incorporated
IMPORTANT NOTICE AND DISCLAIMER
TI PROVIDES TECHNICAL AND RELIABILITY DATA (INCLUDING DATASHEETS), DESIGN RESOURCES (INCLUDING REFERENCE
DESIGNS), APPLICATION OR OTHER DESIGN ADVICE, WEB TOOLS, SAFETY INFORMATION, AND OTHER RESOURCES “AS IS”
AND WITH ALL FAULTS, AND DISCLAIMS ALL WARRANTIES, EXPRESS AND IMPLIED, INCLUDING WITHOUT LIMITATION ANY
IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT OF THIRD
PARTY INTELLECTUAL PROPERTY RIGHTS.
These resources are intended for skilled developers designing with TI products. You are solely responsible for (1) selecting the appropriate
TI products for your application, (2) designing, validating and testing your application, and (3) ensuring your application meets applicable
standards, and any other safety, security, or other requirements. These resources are subject to change without notice. TI grants you
permission to use these resources only for development of an application that uses the TI products described in the resource. Other
reproduction and display of these resources is prohibited. No license is granted to any other TI intellectual property right or to any third
party intellectual property right. TI disclaims responsibility for, and you will fully indemnify TI and its representatives against, any claims,
damages, costs, losses, and liabilities arising out of your use of these resources.
TI’s products are provided subject to TI’s Terms of Sale (www.ti.com/legal/termsofsale.html) or other applicable terms available either on
ti.com or provided in conjunction with such TI products. TI’s provision of these resources does not expand or otherwise alter TI’s applicable
warranties or warranty disclaimers for TI products.
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2019, Texas Instruments Incorporated
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertising