Texas Instruments | AN-1729 DP83640 IEEE 1588 PTP Synchronized Clock Output (Rev. D) | Application notes | Texas Instruments AN-1729 DP83640 IEEE 1588 PTP Synchronized Clock Output (Rev. D) Application notes

Texas Instruments AN-1729 DP83640 IEEE 1588 PTP Synchronized Clock Output (Rev. D) Application notes
Application Report
SNLA099D – September 2007 – Revised April 2013
AN-1729 DP83640 IEEE 1588 PTP Synchronized Clock
Output
.....................................................................................................................................................
ABSTRACT
The DP83640 provides a highly precise, low-jitter clock output that is frequency-aligned to the master
IEEE 1588 clock and can be phase-aligned as well. Empirical testing shows very low jitter (less than 1 ns
peak-to-peak and standard deviation when using the FCO source) and precise phase alignment. While
test results show that the FCO has superior long term jitter performance, using the PGM as a clock source
has the advantage of allowing multimode (10 MB or 100 MB) linked operation.
1
2
3
4
5
Contents
Introduction ..................................................................................................................
Background ..................................................................................................................
Theory ........................................................................................................................
3.1
Rate Correction .....................................................................................................
3.2
Phase Alignment ...................................................................................................
Jitter Test Results ...........................................................................................................
4.1
Test Setup ..........................................................................................................
4.2
Test Conditions .....................................................................................................
4.3
Test Results ........................................................................................................
Clock Phase Error Test Results ...........................................................................................
5.1
Test Setup ..........................................................................................................
5.2
Test Conditions .....................................................................................................
5.3
OSCILLOSCOPE SETUP .........................................................................................
5.4
TEST RESULTS ...................................................................................................
2
2
2
2
3
5
5
5
5
7
7
8
8
8
List of Figures
1
Cycle-to-Cycle Jitter Histogram With FCO Source ..................................................................... 6
2
10 μs Delay Jitter Histogram With FCO Source ........................................................................ 6
3
Cycle-to-Cycle Jitter Histogram With PGM Source ..................................................................... 7
4
10 μs Delay Jitter Histogram With PGM Source ........................................................................ 7
5
Clock Output Phase Error With FCO Source
6
...........................................................................
Clock Output Phase Error With PGM Source ...........................................................................
9
9
List of Tables
1
Test Conditions for Jitter Test ............................................................................................. 5
2
Jitter Results ................................................................................................................. 5
3
Test Conditions For Phase Error Test
4
Oscilloscope Setup For Phase Error Test ............................................................................... 8
5
Clock Phase Error
...................................................................................
..........................................................................................................
8
8
PHYTER is a trademark of Texas Instruments.
All other trademarks are the property of their respective owners.
SNLA099D – September 2007 – Revised April 2013
Submit Documentation Feedback
AN-1729 DP83640 IEEE 1588 PTP Synchronized Clock Output
Copyright © 2007–2013, Texas Instruments Incorporated
1
Introduction
1
www.ti.com
Introduction
Many industrial, test and measurement, and telecommunications applications require highly accurate and
precise clock signals in order to synchronize control signals, capture data, and so forth. The IEEE 1588
Precision Time Protocol (PTP) used in standard Ethernet provides a method for propagating a master
clock time to many nodes in a system. Current implementations rely purely on software or on a mix of
software and FPGA or ASIC hardware. While nodes based on these implementations may be able to
generate a clock output signal based on the master clock time, the precision of such a signal may not be
sufficient for systems requiring extremely low clock jitter. In addition, there may be stringent requirements
for clock phase alignment across the system. The DP83640 precision PHYTER™ provides solutions to
both of these issues.
This document is applicable to the following product: DP83640.
2
Background
The DP83640 includes a highly configurable clock output signal that is syntonized to its internal IEEE
1588 clock. Note that syntonization implies equal frequency but not necessarily equal phase. The nominal
frequency of this clock is an integer division of 250 MHz, (250 MHz/N, where N is an integer from 2 to
255). Therefore, the possible nominal frequencies are discrete values between 980.4 kHz and 125 MHz.
The DP83640 uses software assisted rate correction to eliminate the frequency offset between the local
and master reference clocks. The final output frequency incorporates the same rate correction parameter
(ppm offset) as the internal IEEE 1588 clock time. Since the rate correction is in units of subnanoseconds
(one subnanosecond = 2-32 nanoseconds), the clock output frequency can be finely tuned (to the order of 1
part per billion).
In addition to fixed values, the rate correction can be programmed to operate at one value for a short time
duration of up to 1/2 second (a “temporary rate”). After the temporary rate duration expires, the rate
correction returns to the fixed rate correction value. By correcting additional frequency offset over a short
time interval, the clock output signal will not exhibit discrete jumps in frequency or phase.
The DP83640 also offers a method for aligning the phase of the clock output signal with that of the master
clock. Unlike the trigger outputs of the device, which are generated with a discrete resolution of 8 ns, the
clock output is generated from a highly tunable analog source, either a frequency-controlled oscillator
(FCO) or phase generation module (PGM). The clock output is enabled at power-up by default, running at
25 MHz; however, the 1588 logic, including the 1588 clock, must be initialized prior to operation.
Therefore, the initial phase relationship between the clock output and the 1588 master clock is not known.
However, clever use of the DP83640 features allows alignment of the clock output phase to the phase of
the 1588 clock.
There are advantages to both sources of the 1588 clock output. The FCO offers better jitter performance
but has a smaller correction range and some usage restrictions in order to preserve the clock phase on a
link loss event. The PGM does not have these restrictions and has a larger correction range, but its long
term jitter performance is not as good as that of the FCO.
3
Theory
3.1
Rate Correction
The IEEE 1588 clock output rate correction function utilizes the same logic as that of the internal 1588
clock. The DP83640 includes a 26-bit rate correction parameter in units of subnanoseconds per reference
clock cycle. Under software control, the rate correction is positive when the local reference clock runs
more slowly than the master clock and negative when the local reference clock runs faster than the master
clock. With a rate correction granularity of one subnanosecond per 8 nanosecond clock cycle, the clock
output is tunable with an increment of 2-32 subnanoseconds/8 nanoseconds = 0.029 parts per billion (ppb).
The PTP rate is controlled using the PTP Rate Control Registers (PTP_RATEH and PTP_RATEL) and
PTP Temporary Rate Duration Control Registers (PTP_TRDH and PTP_TRDL).
A fixed rate correction may be programmed as follows:
1. Write the rate direction (0x8000 for higher, 0x0000 for lower) and the upper 10 bits of the value to the
PTP_RATEH register.
2
AN-1729 DP83640 IEEE 1588 PTP Synchronized Clock Output
SNLA099D – September 2007 – Revised April 2013
Submit Documentation Feedback
Copyright © 2007–2013, Texas Instruments Incorporated
Theory
www.ti.com
2. Write the lower 16 bits of the value to the PTP_RATEL register. The rate takes effect upon writing
PTP_RATEL.
Example: Set fixed rate correction to -100 ppm relative to the master.
1. Since the nominal reference clock period is 8 ns, 100 ppm is 0.0008 ns. This is 0.0008 * 232
subnanoseconds, which equals approximately 3435974 subnanoseconds (0x346DC6).
2. Write 0x8034 to PTP_RATEH.
3. Write 0x6DC6 to PTP_RATEL.
A temporary rate correction is programmed in a manner similar to that of the fixed rate correction, except
that bit 14 (0x4000) of PTP_RATEH must also be set. Since the temporary rate takes effect upon writing
the PTP_RATEL register, the PTP temporary rate Duration registers must be programmed before setting
the temporary rate. The rate correction value switches back to the fixed rate value after the temporary rate
duration expires. The temporary rate duration is configured as follows:
1. The temporary rate duration is a 26-bit number in units of clock cycles. At the default 8 ns reference
clock period, the maximum duration is about 537 ms.
2. Write the upper 10 bits of the temporary rate duration to PTP_TRDH.
3. Write the lower 16 bits of the temporary rate duration to PTP_TRDL. The temporary rate duration
setting takes effect upon writing this register, and remains constant until modified via register write.
Often there will not be a need to change the temporary rate duration.
Example: Set a temporary rate correction of +3 ns over 10 ms:
1. For a temporary rate duration of 1 ms at the default reference clock period, you need 10 ms / 8 ns =
1250000 clock cycles (0x1312D0). For +3 ns of correction over 1250000 clock cycles, you need 3 ns /
1250000 = 0.0000024 ns = 10308 subnanoseconds/clock cycle (0x2844).
2. Write 0x0013 to PTP_TRDH
3. Write 0x12D0 to PTP_TRDL
4. Write 0xC000 to PTP_RATEH
5. Write 0x2844 to PTP_RATEL
3.1.1
Maximum Rate Correction
While large rate corrections (greater than 100 ppm) are typically not required, the choice of the source for
the 1588 clock output determines the maximum available rate correction. The maximum effective rate
correction when using the FCO is 0x1555555, which translates to ± 651 ppm. The maximum effective rate
correction when using the PGM is 0x3FFFFFF, which translates to ± 1953 ppm.
3.2
Phase Alignment
Aligning the phase of the clock output requires the following steps:
1. Ensure the clock output pin is enabled.
2. Prior to enabling the PTP synchronization protocol, enable the clock output and the PTP clock.
3. Enable an event monitor for a single event to catch the rising edge of the clock output pin.
4. Determine clock output offset from aligned expected time: clock output period – (event timestamp mod
clock output period).
5. Do a step adjustment to align the clock output.
6. During synchronization, all step adjustments should be in units of the clock output period.
Example: Phase alignment of a 10 MHz clock output:
1. Ensure the clock output pin is enabled. This can be done by strapping the GPIO1 pin high prior to
power-up, or by clearing the CLK_OUT_DISABLE bit (bit 2) in the PHYCR2 register (register 0x1C).
2. Enable the clock output at 10 MHz: write 0x8019 to the PTP_COC register. Note that 0x19 is 25
decimal, to divide the 250 MHz clock by 25. Enable the PTP clock: write 0x0004 to the PTP_CTL
register.
3. Take 100 samples of the CLK_OUT phase error.
SNLA099D – September 2007 – Revised April 2013
Submit Documentation Feedback
AN-1729 DP83640 IEEE 1588 PTP Synchronized Clock Output
Copyright © 2007–2013, Texas Instruments Incorporated
3
Theory
www.ti.com
•
4.
5.
6.
7.
3.2.1
Enable the Event monitor and get the event timestamp:
– Write 0x1C0F to the PTP_EVNT register.
– Write 0x5C0F to the PTP_EVNT register. The first write sets up a single event capture for
CLK_OUT/GPIO12 with Event 7 (though any event may be used). The second write does the
same plus it enables the capture.
– Read the PTP_ESTS register for bit 0 set. If not, wait and repeat this step.
– Once bit 0 of PTP_ESTS has been set, determine the event timestamp length (1-4 16-bit
words) by adding 1 to bits 7:6 of the PTP_ESTS value.
– Ensure the Event number is 7, (the PTP_ESTS value bits 4:2 equal 7).
– Ensure the event was a rising edge. This is indicated by the value of PTP_ESTS bit 5 equaling
1.
– Read the PTP_EDATA register. The event timestamp is returned as follows:
• Event nanoseconds bits 15:0
• Event nanoseconds bits 29:16
• Event seconds bits 15:0
• Event seconds bits 31:16
– Subtract (3 times the reference clock period + 11) from the timestamp; with the typical 8 ns
reference clock period, this value is 35 ns. This corrects for the pin input delay and edge
detection.
• Calculate the phase error as (100 – (event timestamp mod 100)). If the result is equal to the clock
period (100 ns in this case), the phase error is 0. If the phase error is within 10 ns of the clock
period (91 – 99 ns in this case), set a flag “HighValue”. This is equivalent to a negative phase error
of between -9 and -1 ns.
Average the phase error. If there are small positive and negative phase error samples, HighValue is
set and a phase error sample is less than 10 ns, the clock period must be added to the sample in order
for it to be averaged correctly:
• If (HighValue & error[sample]<10) error[sample] += clkout_period
If the average phase error is greater than the clock period, subtract the clock period to get the final
average phase error.
Calculate the correction value, which is the average phase error plus twice the reference clock period:
• Correction = 2 * ref_period + avg_phase_error
Do a step adjustment to the 1588 clock time:
• Write the correction value to PTP_TDR.
• Write PTP_STEP_CLK (0x8) to PTP_CTL.
Maintaining Phase Alignment Through Loss of Link
When using the FCO for generating the CLK_OUT signal, a loss of link may cause the CLK_OUT signal to
stop for a short period of time, resulting in a loss of phase alignment. The DP83640 offers three options
for retaining the alignment of CLK_OUT with the 1588 clock time and triggers upon loss of link.
• Link is established using autonegotiation on a network known to be 100Mb/s. In this case, write
0x803F twice to register 0x1E. This allows the CLK_OUT phase alignment to be preserved following a
loss of link. In addition, the DP83640 can be strapped to advertise 100Mb/s only by either pulling the
LED_SPEED pin low with a 2.2kOhm resistor, or by writing 0x0181 to the Auto-Negotiation
Advertisement Register (ANAR) - register 0x04. Do not advertise 100Mb/s only if the link speed may
need to be 10Mb/s.
• The network speed is 10Mb/s or cannot be guaranteed to be 100Mb/s, and the application can tolerate
the somewhat higher jitter from the PGM source to CLK_OUT. Set bit 14 (PTP_CLKOUT_SEL) in the
PTP Clock Output Control Register (PTP_COC), register 0x14.
4
AN-1729 DP83640 IEEE 1588 PTP Synchronized Clock Output
SNLA099D – September 2007 – Revised April 2013
Submit Documentation Feedback
Copyright © 2007–2013, Texas Instruments Incorporated
Jitter Test Results
www.ti.com
•
Low jitter on CLK_OUT is a requirement and option 1 cannot be used. Force the PHY into a known
100Mb/s or 10Mb/s mode if the network configuration will tolerate it. In the BMCR register (register
0x00), clear bit 12 to disable autonegotiation. Set bit 13 for 100Mb/s and set bit 8 for full duplex.
4
Jitter Test Results
4.1
Test Setup
A series of tests were performed to measure the jitter on the clock output with the devices synchronized to
a master using version 1 of the IEEE 1588 PTP, with a synchronization interval of one second and
temporary rate duration of 10 milliseconds.
A Tektronix TDS784C oscilloscope was used to measure the histogram of the jitter on the signal (10 MHz)
at a single cycle (100 ns) and at a 10 μs delay.
With the probe connected to the clock output signal of the device, the internal histogram function of the
Tektronix TDS784C was used to capture the rising edge of the clock signal at the specified delay time. For
each test condition, approximately 1000 data points were captured, and the peak-to-peak and standard
deviation of the histogram were recorded.
4.2
Test Conditions
Table 1 summarizes the conditions for the jitter test setup.
Table 1. Test Conditions for Jitter Test
4.3
Operating Voltage
3.3 V
Temperature
25 °C
Reference Frequency Source
On-board 25 MHz crystal
Clock Output Frequency
10 MHz
IEEE 1588 PTP Synchronization Interval
1s
Temporary Rate Duration
10 ms
Test Results
Table 2 shows the jitter measurements for the FCO and PGM sources.
Table 2. Jitter Results
10 μs Delay
Cycle-to-Cycle
Source
Peak to Peak (ps)
Standard Deviation
(ps)
FCO
320
53.1
340
58.5
PGM
340
53.2
1160
267.5
SNLA099D – September 2007 – Revised April 2013
Submit Documentation Feedback
Peak to Peak (ps)
Standard Deviation
(ps)
AN-1729 DP83640 IEEE 1588 PTP Synchronized Clock Output
Copyright © 2007–2013, Texas Instruments Incorporated
5
Jitter Test Results
www.ti.com
From this data, it is evident that while short-term (cycle-to-cycle) jitter is comparable between the FCO and
PGM sources, the long-term jitter is worse when using the PGM.
Figure 1, Figure 2, Figure 3, and Figure 4, represent typical histogram plots of the clock output signal
when the DP83640 is synchronized to the Master.
Figure 1. Cycle-to-Cycle Jitter Histogram With FCO Source
Figure 2. 10 μs Delay Jitter Histogram With FCO Source
6
AN-1729 DP83640 IEEE 1588 PTP Synchronized Clock Output
SNLA099D – September 2007 – Revised April 2013
Submit Documentation Feedback
Copyright © 2007–2013, Texas Instruments Incorporated
Clock Phase Error Test Results
www.ti.com
Figure 3. Cycle-to-Cycle Jitter Histogram With PGM Source
Figure 4. 10 μs Delay Jitter Histogram With PGM Source
5
Clock Phase Error Test Results
5.1
Test Setup
The synchronization error to the master is measured by determining the delay from the master clock
output pin to the slave clock output pin. The devices were connected directly using a 1 m CAT5 cable.
IEEE 1588 v1 was used with a 1 second sync period, 100 ms temporary rate duration, timestamp insertion
enabled, and one-step operation enabled.
SNLA099D – September 2007 – Revised April 2013
Submit Documentation Feedback
AN-1729 DP83640 IEEE 1588 PTP Synchronized Clock Output
Copyright © 2007–2013, Texas Instruments Incorporated
7
Clock Phase Error Test Results
5.2
www.ti.com
Test Conditions
Table 3 summarizes the conditions for the clock phase error test setup.
Table 3. Test Conditions For Phase Error Test
5.3
Operating Voltage
3.3 V
Temperature
25 °C
Reference Frequency Source
On-board 25 MHz crystal
Clock Output Frequency
10 MHz
IEEE 1588 PTP Synchronization Interval
1s
Temporary Rate Duration
100 ms
OSCILLOSCOPE SETUP
The configuration of the Tektronix TDS784C oscilloscope is given in Table 4.
Table 4. Oscilloscope Setup For Phase Error Test
5.4
Horizontal Scale
25 ns/div
Vertical Scale (CH1)
1 V/div
Vertical Scale (CH2)
500 mV/div
Trigger Level
1.58 V
Trigger Mode
Rising Edge
Sweep
Main
TEST RESULTS
Table 5 shows the resulting mean and standard deviation for the clock phase error test using each of the
clock sources.
Table 5. Clock Phase Error
Cycle-to-Cycle
8
Source
Mean (ns)
Standard Deviation (ns)
FCO
4.647
5.905
PGM
5.134
6.381
AN-1729 DP83640 IEEE 1588 PTP Synchronized Clock Output
SNLA099D – September 2007 – Revised April 2013
Submit Documentation Feedback
Copyright © 2007–2013, Texas Instruments Incorporated
Clock Phase Error Test Results
www.ti.com
The results indicate that the clock phase error does not depend on the selection of the FCO versus the
PGM.
Figure 5 and Figure 6 represent typical histogram plots of the clock output phase error when the DP83640
is synchronized to the Master.
Figure 5. Clock Output Phase Error With FCO Source
Figure 6. Clock Output Phase Error With PGM Source
SNLA099D – September 2007 – Revised April 2013
Submit Documentation Feedback
AN-1729 DP83640 IEEE 1588 PTP Synchronized Clock Output
Copyright © 2007–2013, Texas Instruments Incorporated
9
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.
Products
Applications
Audio
www.ti.com/audio
Automotive and Transportation
www.ti.com/automotive
Amplifiers
amplifier.ti.com
Communications and Telecom
www.ti.com/communications
Data Converters
dataconverter.ti.com
Computers and Peripherals
www.ti.com/computers
DLP® Products
www.dlp.com
Consumer Electronics
www.ti.com/consumer-apps
DSP
dsp.ti.com
Energy and Lighting
www.ti.com/energy
Clocks and Timers
www.ti.com/clocks
Industrial
www.ti.com/industrial
Interface
interface.ti.com
Medical
www.ti.com/medical
Logic
logic.ti.com
Security
www.ti.com/security
Power Mgmt
power.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Microcontrollers
microcontroller.ti.com
Video and Imaging
www.ti.com/video
RFID
www.ti-rfid.com
OMAP Applications Processors
www.ti.com/omap
TI E2E Community
e2e.ti.com
Wireless Connectivity
www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2013, Texas Instruments Incorporated