Texas Instruments | bq27545-G1 to bq27546-G1 Change List | Application notes | Texas Instruments bq27545-G1 to bq27546-G1 Change List Application notes

Texas Instruments bq27545-G1 to bq27546-G1 Change List Application notes
Application Report
SLUA757 – August 2015
bq27545-G1 to bq27546-G1 Change List
ABSTRACT
This document describes the changes made from bq27545-G1 to bq27546-G1. The latest ordering
information and data sheet is available on the TI Web site.
NOTE:
•
•
•
1
bq27545-G1 ICs cannot be upgraded with bq27546-G1 firmware.
bq27546-G1 includes a new ROM version to enable updated firmware features.
Although the bq27545-G1 reports FW version 2.24 and the bq27546-G1 reports FW
version 2.01, bq27546-G1 is from a new code branch and is therefore more recent.
Introduction
The bq27546-G1 firmware version 2.01 enables several feature additions and performance improvements.
The following newly released orderable part numbers are shipped pre-programmed with this new version
of firmware:
• bbq27546YZFR-G1
• bq27546YZFT-G1
To use the bq27546-G1, download the latest version of Battery Management Studio (bqStudio) evaluation
software from ti.com.
Due to a ROM update, existing bq27545 ICs and EVMs cannot be upgraded to parity with bq27546.
NOTE: If a golden image created for any version of bq27545-G1 is loaded into a bq27546-G1 IC,
the IC will become non-functional and must be replaced. The best practice is to generate a
new golden image (DFI file) for bq27546-G1. If a learning cycle for an existing cell or battery
has already been performed on bq27545-G1, it is acceptable to program the same chemID
and then copy the learned Qmax and Ra values to a new bq27546 golden file.
2
Change Details
Table 1. Change Details
Change
bq27545-G1
bq27546-G1
Comments
ROM version update
Older ROM version
Newer ROM version
bq27545 ICs cannot
be upgraded with
bq27546 firmware.
Support Fast Qmax
Fast Qmax feature is not present.
Allows the use of the FastQmax algorithm feature to
increase the likelihood of Qmax updates for
applications where periodic relaxations may not be
possible.
New enable bit added to Pack Configuration C:
FastQmax
New Feature
Support Battery Trip Point
(BTP)
BTP is not supported.
Provides full BTP compliance for customers designing
Win8 products.
New bit added to Pack Configuration C:
BTP_EN
New Feature
All trademarks are the property of their respective owners.
SLUA757 – August 2015
Submit Documentation Feedback
bq27545-G1 to bq27546-G1 Change List
Copyright © 2015, Texas Instruments Incorporated
1
Change Details
www.ti.com
Table 1. Change Details (continued)
Change
bq27546-G1
Comments
TURBO mode is not supported.
Provides useful current reporting to inform the system
when to throttle back consumption to avoid brownout.
Enables dynamic or load scaling of system current.
New Feature
Add Trace/Downstream
Resistance Feature
Feature is not supported.
Allows applications with non-trivial parasitic trace
resistances between cell and PACK+/– nodes, as well
as between PACK+/– and system +/– nodes. This
enables the gauge to better predict when Terminate
Voltage will be reached on the system side where
power is used, rather than on the cell side.
New Feature
Filtered remaining capacity
reporting options
Filtered RemCap and SOC must
start decreasing immediately on
discharge, and increase
immediately on start of charge,
even if over-charged (>100%) or
over-discharged (below empty). In
these situations, the Unfiltered
values stay at 100% and 0% to
reflect the true state.
New options are added to maintain legacy filtered
behavior or else allow Filtered SOC and RemCap to
hold at 100% and 0% until overcharged and overdischarged conditions pass.
New bits added to Pack Config:
SOCHoldOvrChg
SOCHoldOvrDsg
Feature Change
SOC reporting improvement
Gauge is allowed to report 100%
before charge termination detection
or 0% before Terminate Voltage is
reached.
Gauge can be configured to hold SOC at 99% until
Feature Change
charge termination conditions are detected, and at 0%
until Terminate Voltage is reached.
New enable bits added to Pack Config:
SOCHold99
SOCHold1
Add time-based or instant
synchronization to SOC
smoothing during
RELAXATION
Filtered and Unfiltered capacity
values will necessarily diverge as
conditions change. They can only
be synchronized at full or empty
points, unless RelaxRCJumpOK is
enabled and a temperature change
causes a jump.
Option is added to allow convergence of Filtered
values to match Unfiltered values either over time or
instantly during relaxation.
New enable bits added: Pack Configuration C
[RlxSmEn] and Pack Configuration D
[SMRLXSYNC].
Dedicated Load Select for Fast
Ra Scaling
Same Load Select option used for
simulations both before and after
Fast Ra Scaling starts.
Allows customization of load used for Fast Ra Scaling New Feature
simulations. Helps for better convergence at end of
discharge. New parameter is added: Fast Scale Load
Select.
Disable Thermal model at the
end of discharge
Thermal model may overestimate
Thermal model can be disabled during Fast Ra
heating at end of discharge and can Scaling if needed. Helps for better convergence at
lead to poor convergence to empty. end of discharge.
New bit added to Pack Configuration C:
FConvTempEn
New Feature
Allow resistance updates
based on IR drop
Resistance updates at lower rates
cannot be reliable at times. They
are not allowed if the current is
<C/10.
Gives extra flexibility in allowing resistance updates at
low rates. This leads to reliable resistance updates in
applications with low rates provided the resistance is
high enough (at low temperatures, for example).
New Feature
Improve simulations at Low
Temperature
Improves convergence to 0% at low temperature.
New Feature
T ambient (TA) enhancement
Improve adaptability of the gauging algorithm to
external temperature changes during charging.
New bit added to Pack Configuration D:
PREDICTAMB
New Feature
Use Ra1 instead of
interpolation for DOD positions
below grid1
2
bq27545-G1
Support TURBO mode
Simulation accuracy at low DOD
Improved simulation accuracy at low depth-ofmay not be accurate at times due to discharge. Improves user experience by avoiding
high resistance.
SOC jump at low depth-of-discharge.
bq27545-G1 to bq27546-G1 Change List
Copyright © 2015, Texas Instruments Incorporated
New Feature
New Feature
SLUA757 – August 2015
Submit Documentation Feedback
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.
Products
Applications
Audio
www.ti.com/audio
Automotive and Transportation
www.ti.com/automotive
Amplifiers
amplifier.ti.com
Communications and Telecom
www.ti.com/communications
Data Converters
dataconverter.ti.com
Computers and Peripherals
www.ti.com/computers
DLP® Products
www.dlp.com
Consumer Electronics
www.ti.com/consumer-apps
DSP
dsp.ti.com
Energy and Lighting
www.ti.com/energy
Clocks and Timers
www.ti.com/clocks
Industrial
www.ti.com/industrial
Interface
interface.ti.com
Medical
www.ti.com/medical
Logic
logic.ti.com
Security
www.ti.com/security
Power Mgmt
power.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Microcontrollers
microcontroller.ti.com
Video and Imaging
www.ti.com/video
RFID
www.ti-rfid.com
OMAP Applications Processors
www.ti.com/omap
TI E2E Community
e2e.ti.com
Wireless Connectivity
www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2015, Texas Instruments Incorporated
Was this manual useful for you? yes no