Texas Instruments | HDC2010EVM | User Guides | Texas Instruments HDC2010EVM User guides

Texas Instruments HDC2010EVM User guides
HDC2010EVM User’s Guide
User's Guide
Literature Number: SNAU214
July 2017
Contents
1
2
3
Introduction ......................................................................................................................... 6
Setup .................................................................................................................................. 6
2.1
Input/Output Connector Description ................................................................................... 7
2.2
Hardware Setup .......................................................................................................... 7
2.3
Software Setup ........................................................................................................... 8
2.4
Operation ................................................................................................................ 13
2.5
Reducing the Sensor Thermal Mass ................................................................................. 14
GUI Operation .................................................................................................................... 14
3.1
Starting the GUI ......................................................................................................... 15
3.2
Connecting the EVM ................................................................................................... 16
3.3
Navigating the GUI ..................................................................................................... 18
3.4
Configuring the Device Using Register Page ....................................................................... 20
3.5
Configuring the Device using Configuration Page.................................................................. 28
3.6
Streaming Measurement Data ........................................................................................ 29
3.7
Updating the EVM Firmware .......................................................................................... 39
4
5
6
Board Layout ..................................................................................................................... 43
Schematic ......................................................................................................................... 44
HDC2010EVM Bill of Materials.............................................................................................. 45
2
Table of Contents
SNAU214 – July 2017
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
www.ti.com
List of Figures
1
HDC2010EVM................................................................................................................ 6
2
HDC2010EVM : Sensor Module ........................................................................................... 7
3
HDC2010EVM: Layout Resistors for I2C Address Setting - Top ...................................................... 8
4
GUI Installer Welcome Page ............................................................................................... 9
5
GUI Installer License Agreement ......................................................................................... 10
6
GUI Installer Installation Directory
7
GUI Installer Copying Files................................................................................................ 11
8
EVM Driver Installer Welcome Page..................................................................................... 11
9
EVM Driver Installer In Progress ......................................................................................... 12
10
EVM Driver Installer Complete ........................................................................................... 12
11
GUI Installer Complete
12
HDC2010EVM : PC Interface and Sensor Module .................................................................... 14
13
HDC2010EVM : PC Interface and Smaller Sensor Module
14
HDC2010EVM : Pads for I2C and Supply of the Smaller Sensor Module .......................................... 14
15
GUI Splash Screen......................................................................................................... 15
16
GUI Introduction Page ..................................................................................................... 16
17
GUI Disconnected from EVM ............................................................................................. 17
18
GUI Connected from EVM ................................................................................................ 17
19
GUI Menu Button ........................................................................................................... 18
20
GUI Navigation Menu ...................................................................................................... 19
21
Selecting Auto-Read Interval on Register Page........................................................................ 20
22
Selecting a Register's Current Value for Editing on Register Page
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
.......................................................................................
....................................................................................................
..........................................................
.................................................
Entering New Value for Register on Register Page ...................................................................
Register Value Updated After Changing Value on Register Page ...................................................
Hovering Mouse Over Register Bit Value on Register Page .........................................................
Toggling Register Bit Value on Register Page .........................................................................
Selecting a Register on Register Page ..................................................................................
Reading the Current Device Register Value on Register Page ......................................................
Save Register Values to File on Register Page ........................................................................
Choosing a JSON File Name to Save Register Values ...............................................................
Loading Previously Saved Register Values from File on Register Page ...........................................
Selecting Previously Save Register Value JSON File .................................................................
HDC2010 GUI Configuration Page ......................................................................................
Selecting the Measurement Units for the Data Streaming Graph ...................................................
Data Streaming Graph Showing Only Relative Humidity Percent ...................................................
Data Streaming Graph Showing Only Temperature ...................................................................
Select Log File Button on Data Streaming Page .......................................................................
Selecting the Log File for Data Streaming ..............................................................................
Show Graph Configuration Button on Data Streaming Page .........................................................
Setting the Data Streaming Sample Rate to 1 Second ...............................................................
Manually Setting the Vertical Scale on Data Streaming Graph ......................................................
Starting Data Acquisition on Data Streaming Graph ..................................................................
Data Acquisition In Progress on Data Streaming Page ...............................................................
Stopping Data Acquisition on Data Streaming Graph .................................................................
Show Statistics Button on Data Streaming Graph .....................................................................
Data Statistics on Data Streaming Graph ...............................................................................
Moving the Data Graph Sample View ...................................................................................
SNAU214 – July 2017
Submit Documentation Feedback
List of Figures
Copyright © 2017, Texas Instruments Incorporated
10
13
14
21
21
22
22
23
24
24
25
26
27
27
28
29
30
30
31
32
33
33
34
35
35
36
37
37
38
3
www.ti.com
4
48
Viewing the Entire Buffer on Data Graph ............................................................................... 39
49
Select TI-TXT File Button on Firmware Upload Page ................................................................. 40
50
Selecting TI-TXT Firmware File for Upload to EVM ................................................................... 40
51
Upload Firmware Button on Firmware Upload Page .................................................................. 41
52
Firmware Upload in Progress ............................................................................................. 41
53
Firmware Upload Success ................................................................................................ 42
54
Top Layer Routing
55
Bottom Layer Routing...................................................................................................... 43
56
HDC2010EVM Schematic ................................................................................................. 44
.........................................................................................................
List of Figures
43
SNAU214 – July 2017
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
www.ti.com
List of Tables
1
Device and Package Configurations ...................................................................................... 6
2
I2C Address
..................................................................................................................
SNAU214 – July 2017
Submit Documentation Feedback
List of Tables
Copyright © 2017, Texas Instruments Incorporated
8
5
User's Guide
SNAU214 – July 2017
HDC2010EVM User’s Guide
1
Introduction
The Texas Instruments HDC2010EVM evaluation module (EVM) enables designers to evaluate the
operation and performance of the HDC2010 Relative Humidity and Temperature Sensor.
The EVM contains one HDC2010 (See Table 1).
Table 1. Device and Package Configurations
DEVICE
IC
PACKAGE
U1
HDC2010YPAR
DSBGA - 6 pin (YPA0006)
The EVM hosts an MSP430F5528 microcontroller (µC) as well as the HDC2010. The µC is used to control
the HDC2010 and communicate with a host PC through a USB port. The EVM is designed to be broken
into two sections if desired. The sensor section can be separated from the µC section so that the user can
remotely locate the sensor from the µC section.
2
Setup
This section describes the connectors on the EVM as well and how to properly connect, setup and use the
HDC2010EVM.
Figure 1. HDC2010EVM
6
HDC2010EVM User’s Guide
SNAU214 – July 2017
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
Setup
www.ti.com
2.1
2.1.1
Input/Output Connector Description
J1 – 5x1 Header
This header is not populated and can be installed if the EVM is broken in 2 sections: PC interface and
Sensor. This connector with its counterpart J2 allows the communication of the two sections through a 5wire cable
2.1.2
J1.1
GND
J1.2
SDA
J1.3
SCL
J1.4
INT
J1.5
VDD
J2 – 5x1 Header
This header is not populated and can be installed if the EVM is broken in 2 sections: PC interface and
Sensor. This connector with its counterpart J1 allows the communication of the two sections through a 5wire cable.
2.1.3
J2.1
GND
J2.2
SDA
J2.3
SCL
J2.4
INT
J2.5
VDD
USB Type A Connector
This connector is used for communications with the PC and provides power for the EVM.
2.2
Hardware Setup
The HDC2010EVM power is supplied via the USB connector. The LDO (U4) converts the 5V from the
USB to 3.3V used by the HDC2010 and the MSP430. The EVM may be directly inserted into a USB port
on a PC or laptop, or may be connected to the latter using the appropriate USB cable.
The I2C address of the HDC2010 is set at EVM level at 1000000xb on the EVM. The I2C address has
been set mounting the 0 Ω resistor R12 (refer to Figure 2).
Figure 2. HDC2010EVM : Sensor Module
SNAU214 – July 2017
Submit Documentation Feedback
HDC2010EVM User’s Guide
Copyright © 2017, Texas Instruments Incorporated
7
Setup
www.ti.com
In order to change the I2C address, remove the resistor R12 and populate the R4 with 0 Ω resistor (refer
to Figure 3 )
Figure 3. HDC2010EVM: Layout Resistors for I2C Address Setting - Top
Table 2. I2C Address
ADDR
R12
R4
HDC2010 ADDRESS
0
Short
Open
1000000
1
Open
Short
1000001
In Table 2, the EVM default configuration is in bold.
2.3
2.3.1
Software Setup
System Requirements
The Sensing Solutions GUI supports:
• 64-bit Windows 7
• 64-bit Windows XP
The current GUI does not support 32-bit Windows operating systems. The host machine is required for
device configuration and data streaming. The following steps are necessary to prepare the EVM for the
GUI:
• The GUI and EVM driver must be installed on the host.
• The EVM must be connected to a full speed USB port (USB 1.0 or above).
2.3.2
Sensing Solutions GUI and EVM Driver Installation
The Sensing Solutions GUI and EVM driver installer is packaged in a zip file. Follow these steps to install
the software.
1. Download the software ZIP file from the EVM tool page
2. Extract the downloaded ZIP file
3. Run the included executable
4. Follow all directions from the installer
8
HDC2010EVM User’s Guide
SNAU214 – July 2017
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
Setup
www.ti.com
Figure 4. GUI Installer Welcome Page
SNAU214 – July 2017
Submit Documentation Feedback
HDC2010EVM User’s Guide
Copyright © 2017, Texas Instruments Incorporated
9
Setup
www.ti.com
5. Read the license agreement and if you still wish to install the software, select “I accept the agreement”
and click “Next” as shown in
Figure 5. GUI Installer License Agreement
6. Select the installation directory. If the user installing the software is not a system administrator a
directory not with “Program Files” should be chosen instead of the default.
Figure 6. GUI Installer Installation Directory
10
HDC2010EVM User’s Guide
SNAU214 – July 2017
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
Setup
www.ti.com
7. Wait for all files to install
Figure 7. GUI Installer Copying Files
8. After the files have copied a device driver installer will start. If prompted about an unsigned driver,
choose to install the driver anyways. If running Windows 8 or 8.1, the PC must be started in a “Safe”
mode to install the unsigned driver.
Figure 8. EVM Driver Installer Welcome Page
SNAU214 – July 2017
Submit Documentation Feedback
HDC2010EVM User’s Guide
Copyright © 2017, Texas Instruments Incorporated
11
Setup
www.ti.com
9. Wait for the driver to install
Figure 9. EVM Driver Installer In Progress
10. Click “Finish” after the driver has been installed
Figure 10. EVM Driver Installer Complete
12
HDC2010EVM User’s Guide
SNAU214 – July 2017
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
Setup
www.ti.com
11. Click “Finish” to complete the software installation
Figure 11. GUI Installer Complete
2.4
Operation
When the EVM is connected the host computer, the latter should automatically detect the device.
Launch the GUI. A detailed description of the GUI operation is presented later in this document.
SNAU214 – July 2017
Submit Documentation Feedback
HDC2010EVM User’s Guide
Copyright © 2017, Texas Instruments Incorporated
13
Setup
2.5
www.ti.com
Reducing the Sensor Thermal Mass
The HDC2010EVM can be broken into 2 sections to isolate the thermal mass of the µC from the
HDC2010. Figure 12 shows the board perforations that allow the two sections to be broken apart.
Figure 12. HDC2010EVM : PC Interface and Sensor Module
The communication between the two modules is ensured through the connector J1 and J2 and a 5-wire
cable. In this configuration the thermal mass of the EVM is dramatically reduced, improving the
temperature measurements performances of the HDC2010. The cable connecting J1 to J2 must conform
to I2C cable length constraints. When used in this configuration, the GUI can still be used to communicate
with the EVM and collect data.
If the thermal mass of the sensor section is still excessive, the sensor section can be reduced by breaking
it at the perforation shown inFigure 13. The PCB segment that hosts the HDC2010 is 5.5mm x 5mm.
Figure 13. HDC2010EVM : PC Interface and Smaller Sensor Module
Also in the case where the EVM is broken in 2 sections it is still possible to use the GUI (ensuring the
connections between the modules) or alternatively it is possible to connect the sensor module to a custom
micro-controller. (Refer to Figure 14).
Figure 14. HDC2010EVM : Pads for I2C and Supply of the Smaller Sensor Module
3
GUI Operation
The section describes how to use the GUI
14
HDC2010EVM User’s Guide
SNAU214 – July 2017
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
GUI Operation
www.ti.com
3.1
Starting the GUI
Follow these steps to start the GUI:
1. Select the windows start menu
2. Select “All programs”
3. Select the “Texas Instruments” folder
4. Select the Sensing Solutions GUI
5. Click “Sensing Solutions GUI”
6. Splash screen will appear for at least two seconds.
• Slower PC’s may show a blank splash screen without any texts for up to 20 seconds
Figure 15. GUI Splash Screen
7. After the splash screen is displayed the main window will open. Note: Only one instance of the GUI
may be open at a time!
SNAU214 – July 2017
Submit Documentation Feedback
HDC2010EVM User’s Guide
Copyright © 2017, Texas Instruments Incorporated
15
GUI Operation
www.ti.com
Figure 16. GUI Introduction Page
3.2
Connecting the EVM
Follow these steps to connect the EVM to the GUI:
1. Attach the EVM to the computer via the USB port.
2. The GUI always shows the connection status on the bottom left corner of the GUI
• The initial release of this GUI does not support multiple GUI instances or multiple devices. To
control multiple EVMs, virtual machines may be used or multiple PC’s are required. Future
releases will support multiple EVMs from a single instance of the GUI.
16
HDC2010EVM User’s Guide
SNAU214 – July 2017
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
GUI Operation
www.ti.com
Figure 17. GUI Disconnected from EVM
Figure 18. GUI Connected from EVM
SNAU214 – July 2017
Submit Documentation Feedback
HDC2010EVM User’s Guide
Copyright © 2017, Texas Instruments Incorporated
17
GUI Operation
3.3
www.ti.com
Navigating the GUI
To navigate to different pages of the GUI follow these steps:
1. Click “Menu” in the upper left corner
Figure 19. GUI Menu Button
18
HDC2010EVM User’s Guide
SNAU214 – July 2017
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
GUI Operation
www.ti.com
2. Select the desired page from the menu shown on the left
Figure 20. GUI Navigation Menu
SNAU214 – July 2017
Submit Documentation Feedback
HDC2010EVM User’s Guide
Copyright © 2017, Texas Instruments Incorporated
19
GUI Operation
3.4
www.ti.com
Configuring the Device Using Register Page
The register page allows users to control the device directly with the register values. The user may also
use this page to read the current register values on the device.
3.4.1
Automatically Updating GUI Register Values Using Auto-Read
Autoread will periodically request the register values on the device. Click the dropdown box next to “Auto
Read” to select the update interval.
Figure 21. Selecting Auto-Read Interval on Register Page
3.4.2
Manually Updating Device Register Values
There are two methods to change register values: update the entire register value or change a single bit
within the register. The recommended update mode is always “Immediate” and not “Deferred”. To update
register values, follow these steps.
1. Double-click the current value of the register that needs to be changed. The text will turn into an
editable text box
20
HDC2010EVM User’s Guide
SNAU214 – July 2017
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
GUI Operation
www.ti.com
Figure 22. Selecting a Register's Current Value for Editing on Register Page
2. Type the new value in hexadecimal into the box and click enter. The text box changes to normal text
and the GUI will send a command to the EVM to update the device register
Figure 23. Entering New Value for Register on Register Page
SNAU214 – July 2017
Submit Documentation Feedback
HDC2010EVM User’s Guide
Copyright © 2017, Texas Instruments Incorporated
21
GUI Operation
www.ti.com
Figure 24. Register Value Updated After Changing Value on Register Page
To change individual bit values rather that entire register values follow these steps.
1. Hover the mouse over the desired bit to change
Figure 25. Hovering Mouse Over Register Bit Value on Register Page
22
HDC2010EVM User’s Guide
SNAU214 – July 2017
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
GUI Operation
www.ti.com
2. Double-click the bit to toggle its value and the register’s current value will update automatically
Figure 26. Toggling Register Bit Value on Register Page
3.4.3
Reading Register Values without Auto-Read
To read register values follow these steps.
1. Select the register to update by clicking any column of the register row in the table
SNAU214 – July 2017
Submit Documentation Feedback
HDC2010EVM User’s Guide
Copyright © 2017, Texas Instruments Incorporated
23
GUI Operation
www.ti.com
Figure 27. Selecting a Register on Register Page
2. Click the “Read Register” button to update the selected register’s current value and bit values in the
table
Figure 28. Reading the Current Device Register Value on Register Page
24
HDC2010EVM User’s Guide
SNAU214 – July 2017
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
GUI Operation
www.ti.com
3.4.4
Saving Device Configuration
To save the current register settings of the device follow these steps.
1. Click the button immediately right to the “Auto-Read” selection dropdown
Figure 29. Save Register Values to File on Register Page
SNAU214 – July 2017
Submit Documentation Feedback
HDC2010EVM User’s Guide
Copyright © 2017, Texas Instruments Incorporated
25
GUI Operation
www.ti.com
2. Choose a JSON file name and the directory to save it within. Then click “Save”
Figure 30. Choosing a JSON File Name to Save Register Values
3.4.5
Loading Previously Saved Device Configuration
To load previously saved register settings from a JSON file follow these steps.
1. Click the button furthest right from the “Auto-Read” selection dropdown
26
HDC2010EVM User’s Guide
SNAU214 – July 2017
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
GUI Operation
www.ti.com
Figure 31. Loading Previously Saved Register Values from File on Register Page
2. Select the JSON file with the desired settings and click “Open”
Figure 32. Selecting Previously Save Register Value JSON File
SNAU214 – July 2017
Submit Documentation Feedback
HDC2010EVM User’s Guide
Copyright © 2017, Texas Instruments Incorporated
27
GUI Operation
3.5
www.ti.com
Configuring the Device using Configuration Page
The Sensing Solutions GUI is capable on configuring the device more intuitively than the direct register
values. For more information about configuring the HDC2010 please reference the device datasheet.
Figure 33. HDC2010 GUI Configuration Page
28
HDC2010EVM User’s Guide
SNAU214 – July 2017
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
GUI Operation
www.ti.com
3.6
Streaming Measurement Data
The Sensing Solutions GUI and EVM provide a tool to capture measurement data at rates up to 500Hz.
The section describes how to use the data measurement tools from the "Data Streaming" page accessible
from the GUI menu.
3.6.1
Choosing Graph Units and Visible Channels
Select the drop down menu on top of the y-axis to choose the units of the graph. Available options
include: Temperature and Humidity, and Raw Code.
Figure 34. Selecting the Measurement Units for the Data Streaming Graph
To select which measurements are displayed in the graph, check or uncheck the temperature and relative
humidity boxes shown next to the graph units. Selecting or not selecting the data types only affects the
graph and not the data logged to a file. If a data type is not enabled in the Configuration page it will not
appear on the Data Streaming page.
SNAU214 – July 2017
Submit Documentation Feedback
HDC2010EVM User’s Guide
Copyright © 2017, Texas Instruments Incorporated
29
GUI Operation
www.ti.com
Figure 35. Data Streaming Graph Showing Only Relative Humidity Percent
Figure 36. Data Streaming Graph Showing Only Temperature
30
HDC2010EVM User’s Guide
SNAU214 – July 2017
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
GUI Operation
www.ti.com
3.6.2
Logging Data to a File
Follow these steps to log measurement data to a file.
1. Click the button in the upper right under next to "Click to Select Log File"
Figure 37. Select Log File Button on Data Streaming Page
SNAU214 – July 2017
Submit Documentation Feedback
HDC2010EVM User’s Guide
Copyright © 2017, Texas Instruments Incorporated
31
GUI Operation
www.ti.com
2. Select a file name and directory to save the data to and then click the “Save” button
Figure 38. Selecting the Log File for Data Streaming
3.6.3
Setting the Vertical Axis Scale and Sampling Rate
To set the vertical axis scale or change the sampling rate follow these steps.
1. Click the “Show Graph Configuration” button
32
HDC2010EVM User’s Guide
SNAU214 – July 2017
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
GUI Operation
www.ti.com
Figure 39. Show Graph Configuration Button on Data Streaming Page
2. The sampling rate can be adjusted in the “Sampling Rate” table.
• Note that the GUI sampling rate affects only the graph and logging rate but not the actual device
sampling rate
Figure 40. Setting the Data Streaming Sample Rate to 1 Second
SNAU214 – July 2017
Submit Documentation Feedback
HDC2010EVM User’s Guide
Copyright © 2017, Texas Instruments Incorporated
33
GUI Operation
www.ti.com
3. The vertical scaling can be automatically updated or manually controlled by selecting either checkbox
in the “Vertical Scaling” table.
Figure 41. Manually Setting the Vertical Scale on Data Streaming Graph
34
HDC2010EVM User’s Guide
SNAU214 – July 2017
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
GUI Operation
www.ti.com
3.6.4
Starting and Stopping Measurement Data Acquisition
To start data streaming click the “Start” button.
Figure 42. Starting Data Acquisition on Data Streaming Graph
Figure 43. Data Acquisition In Progress on Data Streaming Page
SNAU214 – July 2017
Submit Documentation Feedback
HDC2010EVM User’s Guide
Copyright © 2017, Texas Instruments Incorporated
35
GUI Operation
www.ti.com
To stop data streaming click the “Stop” button.
Figure 44. Stopping Data Acquisition on Data Streaming Graph
3.6.5
Displaying Measurement Data Statistics
Click the “Show Statistics” button to view the measurement statistics.
36
HDC2010EVM User’s Guide
SNAU214 – July 2017
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
GUI Operation
www.ti.com
Figure 45. Show Statistics Button on Data Streaming Graph
Figure 46. Data Statistics on Data Streaming Graph
SNAU214 – July 2017
Submit Documentation Feedback
HDC2010EVM User’s Guide
Copyright © 2017, Texas Instruments Incorporated
37
GUI Operation
3.6.6
www.ti.com
Navigating the GUI's Data Buffer
After stopping the data stream, the number of data samples displayed can be selected by moving the dual
slider under the graph.
Figure 47. Moving the Data Graph Sample View
38
HDC2010EVM User’s Guide
SNAU214 – July 2017
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
GUI Operation
www.ti.com
Figure 48. Viewing the Entire Buffer on Data Graph
3.7
Updating the EVM Firmware
To upload new firmware to the EVM, navigate to the "Firmware" page from the GUI menu and follow these
steps.
1. Click the button to select a TI-TXT firmware file
SNAU214 – July 2017
Submit Documentation Feedback
HDC2010EVM User’s Guide
Copyright © 2017, Texas Instruments Incorporated
39
GUI Operation
www.ti.com
Figure 49. Select TI-TXT File Button on Firmware Upload Page
2. Select the firmware file and click “Open”
Figure 50. Selecting TI-TXT Firmware File for Upload to EVM
3. Click the “Upload Firmware” button.
40
HDC2010EVM User’s Guide
SNAU214 – July 2017
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
GUI Operation
www.ti.com
Figure 51. Upload Firmware Button on Firmware Upload Page
4. Wait for the firmware to upload. Do NOT disconnect the EVM from the PC at this time! Also note that
the GUI will disconnect from the EVM. The upload process should not take more than one minute.
Figure 52. Firmware Upload in Progress
SNAU214 – July 2017
Submit Documentation Feedback
HDC2010EVM User’s Guide
Copyright © 2017, Texas Instruments Incorporated
41
GUI Operation
www.ti.com
Figure 53. Firmware Upload Success
42
HDC2010EVM User’s Guide
SNAU214 – July 2017
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
Board Layout
www.ti.com
4
Board Layout
Figure 54 and Figure 55 show the board layout for the HDC2010EVM.
Figure 54. Top Layer Routing
Figure 55. Bottom Layer Routing
SNAU214 – July 2017
Submit Documentation Feedback
HDC2010EVM User’s Guide
Copyright © 2017, Texas Instruments Incorporated
43
Schematic
5
www.ti.com
Schematic
Figure 56. HDC2010EVM Schematic
44
HDC2010EVM User’s Guide
SNAU214 – July 2017
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
HDC2010EVM Bill of Materials
www.ti.com
6
HDC2010EVM Bill of Materials
COUNT
REF DES
2
C1, C3
1
1
1
4
DESCRIPTION
FOOTPRINT
PART NUMBER
CAP, CERM, 18pF, 100V, +/-5%, C0G/NP0, 0603
0603
GRM1885C2A180JA01D
C2
CAP, CERM, 0.22uF, 25V, +/-10%, X5R, 0603
0603
06033D224KAT2A
C4
CAP, CERM, 0.47uF, 10V, +/-10%, X7R, 0603
0603
C0603C474K8RACTU
C5
CAP, CERM, 0.22uF, 16V, +/-10%, X7R, 0402
0402
GRM155R71C224KA12D
C6, C7, C11, CAP, CERM, 0.1 µF, 16 V, +/- 5%, X7R, 0402
C12
0402
GRM155R71C104JA88D
1
C8
CAP, CERM, 0.1uF, 10V, +/-10%, X5R, 0201
0201
CL03A104KP3NNNC
1
C9
CAP, CERM, 2200pF, 50V, +/-10%, X7R, 0603
0603
C0603X222K5RACTU
1
C10
CAP, CERM, 10uF, 10V, +/-20%, X5R, 0603
0603
C1608X5R1A106M
1
C13
CAP, CERM, 0.01uF, 25V, +/-5%, C0G/NP0, 0603
0603
C1608C0G1E103J
1
C14
CAP, CERM, 2.2uF, 10V, +/-10%, X5R, 0603
0603
C0603C225K8PACTU
1
D1
LED, Green, SMD
1.7x0.65x0.8mm
LG L29K-G2J1-24-Z
1
D2
LED, Super Red, SMD
LED, 1.6x.6x.8mm
SML-LX0603SRW-TR
1
D3
LED, Blue, SMD
BLUE 0603 LED
LB Q39G-L2N2-35-1
1
D4
Diode, Zener, 5.6V, 500mW, SOD-123
SOD-123
MMSZ5232B-7-F
1
J3
Connector, USB Type A, 4POS R/A, SMD
VLS201610
48037-2200
1
L1
Inductor, Shielded, Ferrite, 10uH, 0.4A, 1.38 ohm,
SMD
2.0x0.95x1.6mm
VLS201610ET-100M
1
Q1
MOSFET, N-CH, 50 V, 0.2 A, SOT-323
SOT-323
BSS138W-7-F
3
R1, R2, R3
RES, 1.0k ohm, 5%, 0.063W, 0402
0402
CRCW04021K00JNED
1
R5, R6, R10
RES, 1.5 k, 5%, 0.063 W, 0402
0402
CRCW04021K50JNED
1
R7
RES, 33k ohm, 5%, 0.063W, 0402
0402
CRCW040233K0JNED
2
R8, R9
RES, 33 ohm, 5%, 0.063W, 0402
0402
CRCW040233R0JNED
1
R11
RES, 1.0 M, 5%, 0.063 W, 0402
0402
CRCW04021M00JNED
1
R12
RES, 0, 5%, 0.063 W, 0402
0402
ERJ-2GE0R00X
1
U1
HDC2010 Low Power Humidity and Temperature
Digital Sensor, YPA0006ABAB
YPA0006ABAB
HDC2010YPAR
1
U2
4-Channels ESD-Protection Array for High-Speed Data DRY0006A
Interfaces
TPD4E004DRY
1
U3
MSP430F5528 Mixed Signal micro-controller
RGC0064B
MSP430F5528IRGC
1
U4
Micropower 150 mA Low-Noise Ultra Low-Dropout
Regulator, 5-pin SOT-23, Pb-Free
MF05A
LP2985AIM5-3.3/NOPB
1
Y1
CRYSTAL 24.000MHZ, 18pF, SMD
ABMM
ABMM-24.000MHZ-B2-T
0
J1, J2
Header, TH, 100mil, 5x1, Gold plated, 230 mil above
insulator
5x1 Header
TSW-105-07-G-S
0
R4
RES, 0, 5%, 0.063 W, 0402
0402
ERJ-2GE0R00X
SNAU214 – July 2017
Submit Documentation Feedback
HDC2010EVM User’s Guide
Copyright © 2017, Texas Instruments Incorporated
45
STANDARD TERMS FOR EVALUATION MODULES
1.
Delivery: TI delivers TI evaluation boards, kits, or modules, including any accompanying demonstration software, components, and/or
documentation which may be provided together or separately (collectively, an “EVM” or “EVMs”) to the User (“User”) in accordance
with the terms set forth herein. User's acceptance of the EVM is expressly subject to the following terms.
1.1 EVMs are intended solely for product or software developers for use in a research and development setting to facilitate feasibility
evaluation, experimentation, or scientific analysis of TI semiconductors products. EVMs have no direct function and are not
finished products. EVMs shall not be directly or indirectly assembled as a part or subassembly in any finished product. For
clarification, any software or software tools provided with the EVM (“Software”) shall not be subject to the terms and conditions
set forth herein but rather shall be subject to the applicable terms that accompany such Software
1.2 EVMs are not intended for consumer or household use. EVMs may not be sold, sublicensed, leased, rented, loaned, assigned,
or otherwise distributed for commercial purposes by Users, in whole or in part, or used in any finished product or production
system.
2
Limited Warranty and Related Remedies/Disclaimers:
2.1 These terms do not apply to Software. The warranty, if any, for Software is covered in the applicable Software License
Agreement.
2.2 TI warrants that the TI EVM will conform to TI's published specifications for ninety (90) days after the date TI delivers such EVM
to User. Notwithstanding the foregoing, TI shall not be liable for a nonconforming EVM if (a) the nonconformity was caused by
neglect, misuse or mistreatment by an entity other than TI, including improper installation or testing, or for any EVMs that have
been altered or modified in any way by an entity other than TI, (b) the nonconformity resulted from User's design, specifications
or instructions for such EVMs or improper system design, or (c) User has not paid on time. Testing and other quality control
techniques are used to the extent TI deems necessary. TI does not test all parameters of each EVM.
User's claims against TI under this Section 2 are void if User fails to notify TI of any apparent defects in the EVMs within ten (10)
business days after delivery, or of any hidden defects with ten (10) business days after the defect has been detected.
2.3 TI's sole liability shall be at its option to repair or replace EVMs that fail to conform to the warranty set forth above, or credit
User's account for such EVM. TI's liability under this warranty shall be limited to EVMs that are returned during the warranty
period to the address designated by TI and that are determined by TI not to conform to such warranty. If TI elects to repair or
replace such EVM, TI shall have a reasonable time to repair such EVM or provide replacements. Repaired EVMs shall be
warranted for the remainder of the original warranty period. Replaced EVMs shall be warranted for a new full ninety (90) day
warranty period.
3
Regulatory Notices:
3.1 United States
3.1.1
Notice applicable to EVMs not FCC-Approved:
FCC NOTICE: This kit is designed to allow product developers to evaluate electronic components, circuitry, or software
associated with the kit to determine whether to incorporate such items in a finished product and software developers to write
software applications for use with the end product. This kit is not a finished product and when assembled may not be resold or
otherwise marketed unless all required FCC equipment authorizations are first obtained. Operation is subject to the condition
that this product not cause harmful interference to licensed radio stations and that this product accept harmful interference.
Unless the assembled kit is designed to operate under part 15, part 18 or part 95 of this chapter, the operator of the kit must
operate under the authority of an FCC license holder or must secure an experimental authorization under part 5 of this chapter.
3.1.2
For EVMs annotated as FCC – FEDERAL COMMUNICATIONS COMMISSION Part 15 Compliant:
CAUTION
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to
operate the equipment.
FCC Interference Statement for Class A EVM devices
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
FCC Interference Statement for Class B EVM devices
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
3.2 Canada
3.2.1
For EVMs issued with an Industry Canada Certificate of Conformance to RSS-210 or RSS-247
Concerning EVMs Including Radio Transmitters:
This device complies with Industry Canada license-exempt RSSs. Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may
cause undesired operation of the device.
Concernant les EVMs avec appareils radio:
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation
est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit
accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Concerning EVMs Including Detachable Antennas:
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser)
gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type
and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for
successful communication. This radio transmitter has been approved by Industry Canada to operate with the antenna types
listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated.
Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited
for use with this device.
Concernant les EVMs avec antennes détachables
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et
d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage
radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope
rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. Le
présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés dans le
manuel d’usage et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne
non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de
l'émetteur
3.3 Japan
3.3.1
Notice for EVMs delivered in Japan: Please see http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_01.page 日本国内に
輸入される評価用キット、ボードについては、次のところをご覧ください。
http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_01.page
3.3.2
Notice for Users of EVMs Considered “Radio Frequency Products” in Japan: EVMs entering Japan may not be certified
by TI as conforming to Technical Regulations of Radio Law of Japan.
If User uses EVMs in Japan, not certified to Technical Regulations of Radio Law of Japan, User is required to follow the
instructions set forth by Radio Law of Japan, which includes, but is not limited to, the instructions below with respect to EVMs
(which for the avoidance of doubt are stated strictly for convenience and should be verified by User):
1.
2.
3.
Use EVMs in a shielded room or any other test facility as defined in the notification #173 issued by Ministry of Internal
Affairs and Communications on March 28, 2006, based on Sub-section 1.1 of Article 6 of the Ministry’s Rule for
Enforcement of Radio Law of Japan,
Use EVMs only after User obtains the license of Test Radio Station as provided in Radio Law of Japan with respect to
EVMs, or
Use of EVMs only after User obtains the Technical Regulations Conformity Certification as provided in Radio Law of Japan
with respect to EVMs. Also, do not transfer EVMs, unless User gives the same notice above to the transferee. Please note
that if User does not follow the instructions above, User will be subject to penalties of Radio Law of Japan.
【無線電波を送信する製品の開発キットをお使いになる際の注意事項】 開発キットの中には技術基準適合証明を受けて
いないものがあります。 技術適合証明を受けていないもののご使用に際しては、電波法遵守のため、以下のいずれかの
措置を取っていただく必要がありますのでご注意ください。
1.
2.
3.
電波法施行規則第6条第1項第1号に基づく平成18年3月28日総務省告示第173号で定められた電波暗室等の試験設備でご使用
いただく。
実験局の免許を取得後ご使用いただく。
技術基準適合証明を取得後ご使用いただく。
なお、本製品は、上記の「ご使用にあたっての注意」を譲渡先、移転先に通知しない限り、譲渡、移転できないものとします。
上記を遵守頂けない場合は、電波法の罰則が適用される可能性があることをご留意ください。 日本テキサス・イ
ンスツルメンツ株式会社
東京都新宿区西新宿6丁目24番1号
西新宿三井ビル
3.3.3
Notice for EVMs for Power Line Communication: Please see http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_02.page
電力線搬送波通信についての開発キットをお使いになる際の注意事項については、次のところをご覧ください。http:/
/www.tij.co.jp/lsds/ti_ja/general/eStore/notice_02.page
3.4 European Union
3.4.1
For EVMs subject to EU Directive 2014/30/EU (Electromagnetic Compatibility Directive):
This is a class A product intended for use in environments other than domestic environments that are connected to a
low-voltage power-supply network that supplies buildings used for domestic purposes. In a domestic environment this
product may cause radio interference in which case the user may be required to take adequate measures.
4
EVM Use Restrictions and Warnings:
4.1 EVMS ARE NOT FOR USE IN FUNCTIONAL SAFETY AND/OR SAFETY CRITICAL EVALUATIONS, INCLUDING BUT NOT
LIMITED TO EVALUATIONS OF LIFE SUPPORT APPLICATIONS.
4.2 User must read and apply the user guide and other available documentation provided by TI regarding the EVM prior to handling
or using the EVM, including without limitation any warning or restriction notices. The notices contain important safety information
related to, for example, temperatures and voltages.
4.3 Safety-Related Warnings and Restrictions:
4.3.1
User shall operate the EVM within TI’s recommended specifications and environmental considerations stated in the user
guide, other available documentation provided by TI, and any other applicable requirements and employ reasonable and
customary safeguards. Exceeding the specified performance ratings and specifications (including but not limited to input
and output voltage, current, power, and environmental ranges) for the EVM may cause personal injury or death, or
property damage. If there are questions concerning performance ratings and specifications, User should contact a TI
field representative prior to connecting interface electronics including input power and intended loads. Any loads applied
outside of the specified output range may also result in unintended and/or inaccurate operation and/or possible
permanent damage to the EVM and/or interface electronics. Please consult the EVM user guide prior to connecting any
load to the EVM output. If there is uncertainty as to the load specification, please contact a TI field representative.
During normal operation, even with the inputs and outputs kept within the specified allowable ranges, some circuit
components may have elevated case temperatures. These components include but are not limited to linear regulators,
switching transistors, pass transistors, current sense resistors, and heat sinks, which can be identified using the
information in the associated documentation. When working with the EVM, please be aware that the EVM may become
very warm.
4.3.2
EVMs are intended solely for use by technically qualified, professional electronics experts who are familiar with the
dangers and application risks associated with handling electrical mechanical components, systems, and subsystems.
User assumes all responsibility and liability for proper and safe handling and use of the EVM by User or its employees,
affiliates, contractors or designees. User assumes all responsibility and liability to ensure that any interfaces (electronic
and/or mechanical) between the EVM and any human body are designed with suitable isolation and means to safely
limit accessible leakage currents to minimize the risk of electrical shock hazard. User assumes all responsibility and
liability for any improper or unsafe handling or use of the EVM by User or its employees, affiliates, contractors or
designees.
4.4 User assumes all responsibility and liability to determine whether the EVM is subject to any applicable international, federal,
state, or local laws and regulations related to User’s handling and use of the EVM and, if applicable, User assumes all
responsibility and liability for compliance in all respects with such laws and regulations. User assumes all responsibility and
liability for proper disposal and recycling of the EVM consistent with all applicable international, federal, state, and local
requirements.
5.
Accuracy of Information: To the extent TI provides information on the availability and function of EVMs, TI attempts to be as accurate
as possible. However, TI does not warrant the accuracy of EVM descriptions, EVM availability or other information on its websites as
accurate, complete, reliable, current, or error-free.
6.
Disclaimers:
6.1 EXCEPT AS SET FORTH ABOVE, EVMS AND ANY MATERIALS PROVIDED WITH THE EVM (INCLUDING, BUT NOT
LIMITED TO, REFERENCE DESIGNS AND THE DESIGN OF THE EVM ITSELF) ARE PROVIDED "AS IS" AND "WITH ALL
FAULTS." TI DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, REGARDING SUCH ITEMS, INCLUDING BUT
NOT LIMITED TO ANY EPIDEMIC FAILURE WARRANTY OR IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT OF ANY THIRD PARTY PATENTS, COPYRIGHTS, TRADE
SECRETS OR OTHER INTELLECTUAL PROPERTY RIGHTS.
6.2 EXCEPT FOR THE LIMITED RIGHT TO USE THE EVM SET FORTH HEREIN, NOTHING IN THESE TERMS SHALL BE
CONSTRUED AS GRANTING OR CONFERRING ANY RIGHTS BY LICENSE, PATENT, OR ANY OTHER INDUSTRIAL OR
INTELLECTUAL PROPERTY RIGHT OF TI, ITS SUPPLIERS/LICENSORS OR ANY OTHER THIRD PARTY, TO USE THE
EVM IN ANY FINISHED END-USER OR READY-TO-USE FINAL PRODUCT, OR FOR ANY INVENTION, DISCOVERY OR
IMPROVEMENT, REGARDLESS OF WHEN MADE, CONCEIVED OR ACQUIRED.
7.
USER'S INDEMNITY OBLIGATIONS AND REPRESENTATIONS. USER WILL DEFEND, INDEMNIFY AND HOLD TI, ITS
LICENSORS AND THEIR REPRESENTATIVES HARMLESS FROM AND AGAINST ANY AND ALL CLAIMS, DAMAGES, LOSSES,
EXPENSES, COSTS AND LIABILITIES (COLLECTIVELY, "CLAIMS") ARISING OUT OF OR IN CONNECTION WITH ANY
HANDLING OR USE OF THE EVM THAT IS NOT IN ACCORDANCE WITH THESE TERMS. THIS OBLIGATION SHALL APPLY
WHETHER CLAIMS ARISE UNDER STATUTE, REGULATION, OR THE LAW OF TORT, CONTRACT OR ANY OTHER LEGAL
THEORY, AND EVEN IF THE EVM FAILS TO PERFORM AS DESCRIBED OR EXPECTED.
8.
Limitations on Damages and Liability:
8.1 General Limitations. IN NO EVENT SHALL TI BE LIABLE FOR ANY SPECIAL, COLLATERAL, INDIRECT, PUNITIVE,
INCIDENTAL, CONSEQUENTIAL, OR EXEMPLARY DAMAGES IN CONNECTION WITH OR ARISING OUT OF THESE
TERMS OR THE USE OF THE EVMS , REGARDLESS OF WHETHER TI HAS BEEN ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. EXCLUDED DAMAGES INCLUDE, BUT ARE NOT LIMITED TO, COST OF REMOVAL OR
REINSTALLATION, ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES, RETESTING,
OUTSIDE COMPUTER TIME, LABOR COSTS, LOSS OF GOODWILL, LOSS OF PROFITS, LOSS OF SAVINGS, LOSS OF
USE, LOSS OF DATA, OR BUSINESS INTERRUPTION. NO CLAIM, SUIT OR ACTION SHALL BE BROUGHT AGAINST TI
MORE THAN TWELVE (12) MONTHS AFTER THE EVENT THAT GAVE RISE TO THE CAUSE OF ACTION HAS
OCCURRED.
8.2 Specific Limitations. IN NO EVENT SHALL TI'S AGGREGATE LIABILITY FROM ANY USE OF AN EVM PROVIDED
HEREUNDER, INCLUDING FROM ANY WARRANTY, INDEMITY OR OTHER OBLIGATION ARISING OUT OF OR IN
CONNECTION WITH THESE TERMS, , EXCEED THE TOTAL AMOUNT PAID TO TI BY USER FOR THE PARTICULAR
EVM(S) AT ISSUE DURING THE PRIOR TWELVE (12) MONTHS WITH RESPECT TO WHICH LOSSES OR DAMAGES ARE
CLAIMED. THE EXISTENCE OF MORE THAN ONE CLAIM SHALL NOT ENLARGE OR EXTEND THIS LIMIT.
9.
Return Policy. Except as otherwise provided, TI does not offer any refunds, returns, or exchanges. Furthermore, no return of EVM(s)
will be accepted if the package has been opened and no return of the EVM(s) will be accepted if they are damaged or otherwise not in
a resalable condition. If User feels it has been incorrectly charged for the EVM(s) it ordered or that delivery violates the applicable
order, User should contact TI. All refunds will be made in full within thirty (30) working days from the return of the components(s),
excluding any postage or packaging costs.
10. Governing Law: These terms and conditions shall be governed by and interpreted in accordance with the laws of the State of Texas,
without reference to conflict-of-laws principles. User agrees that non-exclusive jurisdiction for any dispute arising out of or relating to
these terms and conditions lies within courts located in the State of Texas and consents to venue in Dallas County, Texas.
Notwithstanding the foregoing, any judgment may be enforced in any United States or foreign court, and TI may seek injunctive relief
in any United States or foreign court.
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2017, Texas Instruments Incorporated
IMPORTANT NOTICE FOR TI DESIGN INFORMATION AND RESOURCES
Texas Instruments Incorporated (‘TI”) technical, application or other design advice, services or information, including, but not limited to,
reference designs and materials relating to evaluation modules, (collectively, “TI Resources”) are intended to assist designers who are
developing applications that incorporate TI products; by downloading, accessing or using any particular TI Resource in any way, you
(individually or, if you are acting on behalf of a company, your company) agree to use it solely for this purpose and subject to the terms of
this Notice.
TI’s provision of TI Resources does not expand or otherwise alter TI’s applicable published warranties or warranty disclaimers for TI
products, and no additional obligations or liabilities arise from TI providing such TI Resources. TI reserves the right to make corrections,
enhancements, improvements and other changes to its TI Resources.
You understand and agree that you remain responsible for using your independent analysis, evaluation and judgment in designing your
applications and that you have full and exclusive responsibility to assure the safety of your applications and compliance of your applications
(and of all TI products used in or for your applications) with all applicable regulations, laws and other applicable requirements. You
represent that, with respect to your applications, you have all the necessary expertise to create and implement safeguards that (1)
anticipate dangerous consequences of failures, (2) monitor failures and their consequences, and (3) lessen the likelihood of failures that
might cause harm and take appropriate actions. You agree that prior to using or distributing any applications that include TI products, you
will thoroughly test such applications and the functionality of such TI products as used in such applications. TI has not conducted any
testing other than that specifically described in the published documentation for a particular TI Resource.
You are authorized to use, copy and modify any individual TI Resource only in connection with the development of applications that include
the TI product(s) identified in such TI Resource. NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO
ANY OTHER TI INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY TECHNOLOGY OR INTELLECTUAL PROPERTY
RIGHT OF TI OR ANY THIRD PARTY IS GRANTED HEREIN, including but not limited to any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
regarding or referencing third-party products or services does not constitute a license to use such products or services, or a warranty or
endorsement thereof. Use of TI Resources may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
TI RESOURCES ARE PROVIDED “AS IS” AND WITH ALL FAULTS. TI DISCLAIMS ALL OTHER WARRANTIES OR
REPRESENTATIONS, EXPRESS OR IMPLIED, REGARDING TI RESOURCES OR USE THEREOF, INCLUDING BUT NOT LIMITED TO
ACCURACY OR COMPLETENESS, TITLE, ANY EPIDEMIC FAILURE WARRANTY AND ANY IMPLIED WARRANTIES OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL
PROPERTY RIGHTS.
TI SHALL NOT BE LIABLE FOR AND SHALL NOT DEFEND OR INDEMNIFY YOU AGAINST ANY CLAIM, INCLUDING BUT NOT
LIMITED TO ANY INFRINGEMENT CLAIM THAT RELATES TO OR IS BASED ON ANY COMBINATION OF PRODUCTS EVEN IF
DESCRIBED IN TI RESOURCES OR OTHERWISE. IN NO EVENT SHALL TI BE LIABLE FOR ANY ACTUAL, DIRECT, SPECIAL,
COLLATERAL, INDIRECT, PUNITIVE, INCIDENTAL, CONSEQUENTIAL OR EXEMPLARY DAMAGES IN CONNECTION WITH OR
ARISING OUT OF TI RESOURCES OR USE THEREOF, AND REGARDLESS OF WHETHER TI HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES.
You agree to fully indemnify TI and its representatives against any damages, costs, losses, and/or liabilities arising out of your noncompliance with the terms and provisions of this Notice.
This Notice applies to TI Resources. Additional terms apply to the use and purchase of certain types of materials, TI products and services.
These include; without limitation, TI’s standard terms for semiconductor products http://www.ti.com/sc/docs/stdterms.htm), evaluation
modules, and samples (http://www.ti.com/sc/docs/sampterms.htm).
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2017, Texas Instruments Incorporated
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising