Texas Instruments | CC3100 SimpleLink Wi-Fi and IoT Solution (Rev. D) | User Guides | Texas Instruments CC3100 SimpleLink Wi-Fi and IoT Solution (Rev. D) User guides

Texas Instruments CC3100 SimpleLink Wi-Fi and IoT Solution (Rev. D) User guides
CC3100 SimpleLink™ Wi-Fi® and IoT Solution
Getting Started Guide
User's Guide
Literature Number: SWRU375D
June 2014 – Revised May 2018
Contents
1
2
Trademarks ......................................................................................................................... 4
Introduction ......................................................................................................................... 4
2.1
3
Prerequisites .............................................................................................................. 4
Getting Started .................................................................................................................... 4
3.1
Download and Install Software ......................................................................................... 4
.................................................................................................... 4
4
Getting Started with SimpleLink Studio .................................................................................. 5
4.1
Configure Boards ......................................................................................................... 5
4.2
Run the Software ......................................................................................................... 8
5
Getting Started with the MSP430F5529.................................................................................. 13
5.1
Configure Boards ....................................................................................................... 13
5.2
Run the Software ....................................................................................................... 15
6
Summary ........................................................................................................................... 20
7
Acronyms Used.................................................................................................................. 20
Revision History .......................................................................................................................... 21
3.2
2
Update Service Pack
Table of Contents
SWRU375D – June 2014 – Revised May 2018
Submit Documentation Feedback
Copyright © 2014–2018, Texas Instruments Incorporated
www.ti.com
List of Figures
1
CC3100BOOST .............................................................................................................. 5
2
CC31XXEMUBOOST ....................................................................................................... 6
3
Connect the CC3100BOOST to the CC31XXEMUBOOST ............................................................ 7
4
Device Manager.............................................................................................................. 8
5
MinGW Installation Screen ................................................................................................. 9
6
Import Existing Code ....................................................................................................... 10
7
Paths and Symbols
8
9
10
11
12
13
14
15
16
17
18
........................................................................................................
Eclipse Output Console ...................................................................................................
CC3100BOOST ............................................................................................................
Jumpers on the MSP430F5529 Launchpad ............................................................................
Connect the CC3100BOOST to the MSP430F5529 Launchpad ....................................................
Select CCS Projects to Import ............................................................................................
Define SSID_Name ........................................................................................................
Launch Tera Term .........................................................................................................
Tera Term VT ...............................................................................................................
Macro Definition of SSID_Name .........................................................................................
Launch Tera Term .........................................................................................................
Tera Term VT ...............................................................................................................
SWRU375D – June 2014 – Revised May 2018
Submit Documentation Feedback
List of Figures
Copyright © 2014–2018, Texas Instruments Incorporated
11
11
13
14
15
16
17
17
18
18
19
19
3
User's Guide
SWRU375D – June 2014 – Revised May 2018
CC3100 SimpleLink™ Wi-Fi® and IoT Solution Getting
Started Guide
ABSTRACT
This guide is intended to assist users in the initial setup and demonstration of the Getting Started with
WLAN Station application. The guide explains how to install an Integrated Development Environment
(IDE), and then compile, download, and debug Getting Started with WLAN Station.
1
Trademarks
SimpleLink is a trademark of Texas Instruments.
Microsoft, Windows are registered trademarks of Microsoft.
Wi-Fi is a registered trademark of Wi-Fi Alliance.
2
Introduction
2.1
Prerequisites
The user should have the following items:
• One CC3100BOOST
• One CC31XXEMUBOOST or MSP430F5529 Launchpad
• An 802.11b/g/n Wireless Access Point (AP)
• A computer running Microsoft® Windows® 7 or XP operating systems.
3
Getting Started
3.1
Download and Install Software
Download and install the following software:
• CC3100 SDK package http://www.ti.com/tool/cc3100sdk
– This guide assumes the use of the default installation folder C:\TI\CC3100SDK_<x.x.x>\. .
3.2
Update Service Pack
If the board is not already flashed with the service pack for SDK_<x.x.x>, the latest service pack for
SDK_<x.x.x> must be flashed on the CC3100. The latest service pack can be downloaded from
http://www.ti.com/tool/cc3100sdk. Refer to the UNIFLASH Quick Start guide for details on flashing the
service pack to the CC3100
(http://processors.wiki.ti.com/index.php/CC31xx_%26_CC32xx_UniFlash#Service_Pack_Programming).
Details on setting up the hardware for flashing can be found in Section 4.1 .
4
CC3100 SimpleLink™ Wi-Fi® and IoT Solution Getting Started Guide
Copyright © 2014–2018, Texas Instruments Incorporated
SWRU375D – June 2014 – Revised May 2018
Submit Documentation Feedback
Getting Started with SimpleLink Studio
www.ti.com
4
Getting Started with SimpleLink Studio
4.1
Configure Boards
1. The jumpers on the CC3100BOOST should be connected as shown in Figure 1.
Figure 1. CC3100BOOST
SWRU375D – June 2014 – Revised May 2018
Submit Documentation Feedback
CC3100 SimpleLink™ Wi-Fi® and IoT Solution Getting Started Guide
Copyright © 2014–2018, Texas Instruments Incorporated
5
Getting Started with SimpleLink Studio
www.ti.com
2. The jumpers on the CC31XXEMUBOOST should be connected as shown in Figure 2.
Figure 2. CC31XXEMUBOOST
6
CC3100 SimpleLink™ Wi-Fi® and IoT Solution Getting Started Guide
Copyright © 2014–2018, Texas Instruments Incorporated
SWRU375D – June 2014 – Revised May 2018
Submit Documentation Feedback
Getting Started with SimpleLink Studio
www.ti.com
3. Connect the CC3100BOOST to the CC31XXEMUBOOST as shown in Figure 3.
Figure 3. Connect the CC3100BOOST to the CC31XXEMUBOOST
4. Connect the J6 port CC31XXEMUBOOST to the PC using the provided micro-USB cable.
5. The CC3100BOOST is now visible in the Device Manager as shown in Figure 4. The user may see
two COM ports instead of four.
SWRU375D – June 2014 – Revised May 2018
Submit Documentation Feedback
CC3100 SimpleLink™ Wi-Fi® and IoT Solution Getting Started Guide
Copyright © 2014–2018, Texas Instruments Incorporated
7
Getting Started with SimpleLink Studio
www.ti.com
Figure 4. Device Manager
4.2
Run the Software
The Getting Started with WLAN Station example uses SimpleLink Studio. This example performs the
following functions:
1. Program restores WLAN configuration to factory default
2. Prompts the user for the SSID of an AP
3. Prompts the user for the security type
4. Prompts the user for the password to the AP
5. Attempts to acquire an IP address through DHCP
6. Attempts to reach the internet
NOTE: For full compatibility ensure Visual Studio 2010 is used. Newer versions of Visual Studio will
not work with the device. Visual Studio 2012 works with the "getting started" example, but
gives the error code -2003 for the weather example, and error code -2005 for the email app.
Option 1. Microsoft Visual Studio:
1. Download and install Microsoft Visual Studio Express 2010 from http://www.visualstudio.com/enus/downloads/download-visual-studio-vs#DownloadFamilies_4.
2. Open Microsoft Visual Studio Express, and select File>Open>Project/Solution.
3. Navigate to C:\TI\CC3100SDK_<x.x.x>\cc3100sdk\platform\simplelinkstudio\example_project_vs\getting_started_with_station , and open
getting_started.sln.
4. Select Build>Build Solution from the menu.
5. When building is complete, select Debug>Start Debugging from the menu.
8
CC3100 SimpleLink™ Wi-Fi® and IoT Solution Getting Started Guide
Copyright © 2014–2018, Texas Instruments Incorporated
SWRU375D – June 2014 – Revised May 2018
Submit Documentation Feedback
Getting Started with SimpleLink Studio
www.ti.com
Option 2. Eclipse:
1. Download and install the latest version of Java: https://www.java.com/en/download/. Install the correct
version for the system (64-bit or 32-bit).
2. Download and extract Eclipse from http://www.eclipse.org/downloads/. Choose the Eclipse IDE for
C/C++ Developers package. Install the correct version for the system (64-bit or 32-bit).
3. Download and install MinGW from
http://sourceforge.net/projects/mingw/files/latest/download?source=files. During installation, ensure the
following configurations are selected:
a. Set the installation location as C:\MinGW.
b. In the MinGW Installation Screen, select packages for mingw32-base and mingw32-gcc-g++ as
shown in Figure 5.
Figure 5. MinGW Installation Screen
c. After selecting the packages, choose Installation>Apply Changes from the menu, then press Apply.
d. Select Installation>Quit from the menu to quit the installer.
4. After a successful MinGW installation, add the path (c:\MinGW\bin\) to the Windows environment
variable path by going into Control Panel>System>Advanced System Settings>Environment Variables.
Under System Variables, select PATH and press Edit. Append “;C:\MinGW\bin\” to the end of the line
and press Ok.
5. Open Eclipse by running eclipse.exe from the extracted Eclipse folder.
6. In the "Select a workspace," choose your desired workspace directory (for example:
C:\Users\myself\Desktop\eclipse_workspace). This directory should be different from the user's other
versions of Eclipse.
7. From the menu, select File>New>Makefile Project with Existing Code.
8. Enter ‘Getting_started’ as the project name.
9. For Existing Code Location, enter C:\TI\CC3100SDK_<x.x.x.>\cc3100sdk\platform\simplelinkstudio\example_project_eclipse\getting_started_with_station .
10. For Toolchain for indexer settings, choose “MinGW GCC” as shown in Figure 6.
SWRU375D – June 2014 – Revised May 2018
Submit Documentation Feedback
CC3100 SimpleLink™ Wi-Fi® and IoT Solution Getting Started Guide
Copyright © 2014–2018, Texas Instruments Incorporated
9
Getting Started with SimpleLink Studio
www.ti.com
Figure 6. Import Existing Code
11.
12.
13.
14.
15.
Press Finish.
Select Window>Show View>Project Explorer from the menu.
Select the Getting_started project in the Project Explorer, and select File>Properties from the menu.
In the Project Explorer window, right click on <Project_Folder_Name>, then select Property.
Expand the C/C++ Build menu, and select Tool Chain Editor. Under Current Builder, Select "Gnu
Make Builder", then click Apply.
16. Click the C/C++ Build menu and do the following:
a. Uncheck 'Use the default build command.'
b. Type mingw32-make -f Makefile in the Build command.
c. Uncheck 'Generate Makefiles automatically.'
d. Set the Build Directory as: ${workspace_loc:/Getting_started}
17. Select Environment in the C/C++ Build menu. Ensure the value of MSYS_HOME is empty, then click
Apply.
18. Click the C/C++ General menu, and select Paths and Symbols. Under the Includes tab, in the
10
CC3100 SimpleLink™ Wi-Fi® and IoT Solution Getting Started Guide
Copyright © 2014–2018, Texas Instruments Incorporated
SWRU375D – June 2014 – Revised May 2018
Submit Documentation Feedback
Getting Started with SimpleLink Studio
www.ti.com
Languages column, select GNU C. Press the Add button to add the directory:
C:\TI\CC3100SDK_<x.x.x>\cc3100-sdk\simplelink\include .
Figure 7. Paths and Symbols
19. Press OK.
20. To fix a known bug in the Eclipse console output, add the following line of code to the beginning of the
main function:
setvbuf(stdout, NULL, _IONBF, 0);
Figure 8. Eclipse Output Console
21. Save the file, and select Project>Clean from the menu.
22. Select the Getting_started project and press OK.
23. Select the Getting_started project from Project Explorer, and from the menu select Project>Build
SWRU375D – June 2014 – Revised May 2018
Submit Documentation Feedback
CC3100 SimpleLink™ Wi-Fi® and IoT Solution Getting Started Guide
Copyright © 2014–2018, Texas Instruments Incorporated
11
Getting Started with SimpleLink Studio
www.ti.com
Project.
24. Press Ctrl+F11 to start the program.
12
CC3100 SimpleLink™ Wi-Fi® and IoT Solution Getting Started Guide
Copyright © 2014–2018, Texas Instruments Incorporated
SWRU375D – June 2014 – Revised May 2018
Submit Documentation Feedback
Getting Started with the MSP430F5529
www.ti.com
5
Getting Started with the MSP430F5529
5.1
Configure Boards
1. The jumpers on the CC3100BOOST should be connected as shown in Figure 9.
Figure 9. CC3100BOOST
SWRU375D – June 2014 – Revised May 2018
Submit Documentation Feedback
CC3100 SimpleLink™ Wi-Fi® and IoT Solution Getting Started Guide
Copyright © 2014–2018, Texas Instruments Incorporated
13
Getting Started with the MSP430F5529
www.ti.com
2. The jumpers on the MSP430F5529 Launchpad should be connected as shown in Figure 10.
Figure 10. Jumpers on the MSP430F5529 Launchpad
14
CC3100 SimpleLink™ Wi-Fi® and IoT Solution Getting Started Guide
Copyright © 2014–2018, Texas Instruments Incorporated
SWRU375D – June 2014 – Revised May 2018
Submit Documentation Feedback
Getting Started with the MSP430F5529
www.ti.com
3. Connect the CC3100BOOST to the MSP430F5529 Launchpad as shown in Figure 11.
Figure 11. Connect the CC3100BOOST to the MSP430F5529 Launchpad
4. Connect a Micro-USB cable from J7 on the Boosterpack to the Windows PC, and connect a MicroUSB cable from J401 on the MSP430F5529 Launchpad to the Windows PC.
5.2
Run the Software
The example shown provides output using UART. To see the output from the program, download Tera
Term (or similar software) from http://en.sourceforge.jp/projects/ttssh2/releases/
Option 1. Code Composer Studio (CCS):
1. Download and run the Code Composer Studio 6.1.0 (CCS) installation wizard (ccs_setup_win32.exe)
from the TI website or from the CCS Wiki page. The program must be Version 6.1.0.00104 or later.
When prompted to select processor support, select the MSP Ultra Low Power MCUs processor
support option. The remaining options for the installer should be left as the default. Installation may
take up to an hour.
2. Open CCS, and choose File>Import from the menu. Under C/C++, choose CCS Projects.
3. Under Select Search Directory, enter the path: C:\TI\CC3100SDK_<x.x.x>\cc3100sdk\platform\msp430f5529lp\example_project_ccs .
4. Check the project getting_started_with_wlan_station and press Finish.
SWRU375D – June 2014 – Revised May 2018
Submit Documentation Feedback
CC3100 SimpleLink™ Wi-Fi® and IoT Solution Getting Started Guide
Copyright © 2014–2018, Texas Instruments Incorporated
15
Getting Started with the MSP430F5529
www.ti.com
Figure 12. Select CCS Projects to Import
5. Open the sl_common.h file located at the path C:\TI\CC3100SDK_<x.x.x>\cc3100sdk\examples\common\.
6. Edit sl_common.h to use the SSID, security type, and security key of the AP being used. Edit the
macros SSID_NAME, SEC_TYPE, and PASSKEY to contain the AP information as shown in
Figure 13. The security types supported for this demo are WPA/WPA2, WEP (5/13 ASCII), and Open.
WEP supports key index 1 only. For Open security, define SEC_TYPE as SL_SEC_TYPE_OPEN. For
WPA and WPA2 security, define it as SL_SEC_TYPE_WPA. For WEP security, define it as
SL_SEC_TYPE_WEP.
16
CC3100 SimpleLink™ Wi-Fi® and IoT Solution Getting Started Guide
Copyright © 2014–2018, Texas Instruments Incorporated
SWRU375D – June 2014 – Revised May 2018
Submit Documentation Feedback
Getting Started with the MSP430F5529
www.ti.com
Figure 13. Define SSID_Name
7. Select the getting_started_with_wlan_station project in Project Explorer and select Project>Build
Project from the menu.
8. Launch Tera Term, and create a new serial connection to the MSP430F5529 Launchpad COM port as
shown in Figure 14. The baud rate should remain at 9600.
9. Press F11on the CCS window to start debugging.
Figure 14. Launch Tera Term
10. If the CC3100 successfully completes all steps, the serial output appears as shown in Figure 15.
SWRU375D – June 2014 – Revised May 2018
Submit Documentation Feedback
CC3100 SimpleLink™ Wi-Fi® and IoT Solution Getting Started Guide
Copyright © 2014–2018, Texas Instruments Incorporated
17
Getting Started with the MSP430F5529
www.ti.com
Figure 15. Tera Term VT
Option 2. IAR Workbench
1. Install IAR Workbench for MSP430 version 6.20 or later: http://www.iar.com/en/Products/IAREmbedded-Workbench/TI-MSP430/.
2. Open IAR Workbench and select File>Open>Workspace from the menu.
3. Select the project: C:\TI\CC3100SDK_1.2.0\cc3100sdk\platform\msp430f5529lp\example_project_iar\getting_started_with_wlan_station\
getting_started_with_wlan.eww .
4. Open the sl_common.h file located at the path C:\TI\CC3100SDK_<x.x.x>\cc3100sdk\examples\common\ .
5. Edit sl_common.h to use the SSID, security type and security key of the AP being used. Edit the
macros SSID_NAME, SEC_TYPE, and PASSKEY to contain the AP information as shown in
Figure 16. The security types supported for this demo are WPA/WPA2 and Open. For Open security,
define SEC_TYPE as SL_SEC_TYPE_OPEN. For WPA and WPA2 security, define it as
SL_SEC_TYPE_WPA.
Figure 16. Macro Definition of SSID_Name
6. Select Project>Rebuild All from the menu.
7. Launch Tera Term, and create a new serial connection to the MSP430F5529 Launchpad COM port as
shown in Figure 17. The baud rate should remain at 9600.
8. After building is finished, select Project>Download and Debug from the menu to start debugging.
18
CC3100 SimpleLink™ Wi-Fi® and IoT Solution Getting Started Guide
Copyright © 2014–2018, Texas Instruments Incorporated
SWRU375D – June 2014 – Revised May 2018
Submit Documentation Feedback
Getting Started with the MSP430F5529
www.ti.com
Figure 17. Launch Tera Term
9. If the CC3100 successfully completes all steps, the serial output appears as shown in Figure 18.
Figure 18. Tera Term VT
SWRU375D – June 2014 – Revised May 2018
Submit Documentation Feedback
CC3100 SimpleLink™ Wi-Fi® and IoT Solution Getting Started Guide
Copyright © 2014–2018, Texas Instruments Incorporated
19
Summary
6
www.ti.com
Summary
After the development environment has been set up, see the following resources for further assistance in
development:
• CC3100 Programmer's Guide – This guide contains information on how to use the SimpleLink API for
writing WLAN-enabled applications.
• Uniflash – The Uniflash tool is used for manually storing files on the external serial flash. This includes
the SimpleLink firmware patch file and any configuration files, security certificates, web pages, and so
forth.
• CC3100 Wiki – All information and tools for the CC3100, including the above, can be found on the
CC3100 Wiki page.
7
Acronyms Used
STA – Wi-Fi Station
AP – Wi-Fi Access Point
WLAN – Wireless LAN
CCS – Code Composer Studio
GCC – GNU Compiler Collection
20
CC3100 SimpleLink™ Wi-Fi® and IoT Solution Getting Started Guide
Copyright © 2014–2018, Texas Instruments Incorporated
SWRU375D – June 2014 – Revised May 2018
Submit Documentation Feedback
Revision History
www.ti.com
Revision History
NOTE: Page numbers for previous revisions may differ from page numbers in the current version.
Changes from C Revision (March 2016) to D Revision .................................................................................................. Page
•
•
Updated Note. ............................................................................................................................. 8
Added Eclipse Output Console image. ............................................................................................... 11
SWRU375D – June 2014 – Revised May 2018
Submit Documentation Feedback
Revision History
Copyright © 2014–2018, Texas Instruments Incorporated
21
IMPORTANT NOTICE AND DISCLAIMER
TI PROVIDES TECHNICAL AND RELIABILITY DATA (INCLUDING DATASHEETS), DESIGN RESOURCES (INCLUDING REFERENCE
DESIGNS), APPLICATION OR OTHER DESIGN ADVICE, WEB TOOLS, SAFETY INFORMATION, AND OTHER RESOURCES “AS IS”
AND WITH ALL FAULTS, AND DISCLAIMS ALL WARRANTIES, EXPRESS AND IMPLIED, INCLUDING WITHOUT LIMITATION ANY
IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT OF THIRD
PARTY INTELLECTUAL PROPERTY RIGHTS.
These resources are intended for skilled developers designing with TI products. You are solely responsible for (1) selecting the appropriate
TI products for your application, (2) designing, validating and testing your application, and (3) ensuring your application meets applicable
standards, and any other safety, security, or other requirements. These resources are subject to change without notice. TI grants you
permission to use these resources only for development of an application that uses the TI products described in the resource. Other
reproduction and display of these resources is prohibited. No license is granted to any other TI intellectual property right or to any third
party intellectual property right. TI disclaims responsibility for, and you will fully indemnify TI and its representatives against, any claims,
damages, costs, losses, and liabilities arising out of your use of these resources.
TI’s products are provided subject to TI’s Terms of Sale (www.ti.com/legal/termsofsale.html) or other applicable terms available either on
ti.com or provided in conjunction with such TI products. TI’s provision of these resources does not expand or otherwise alter TI’s applicable
warranties or warranty disclaimers for TI products.
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2019, Texas Instruments Incorporated