Installation Instructions:
TABLE 3: Environmental Conditions
Environmental Conditions
Rating
Temperature Rating
105°C (221°F)
Flame Rating
UL94-0
Rated for a limited number of current-interrupting operations.
WARNING
Electrical Shock Hazard.
Contact with high voltage may cause falling, serious injury, or death.
Disconnect power before servicing.
This disconnect is rated for the following voltage/current combinations:
Disconnect de-mate / mate installation
1. To de-mate, grasp disconnect at each end and pull apart to separate the disconnect
halves. Do NOT pull on wires.
2. To mate the disconnect, grasp each disconnect half, align halves, and push together.
3. Completed connection should appear as shown.
Electrical Fire Hazard.
Use in application exceeding voltage and current ratings listed can cause an
electrical fire resulting in serious injury or death.
Only use in accordance with Tables 1, 2 and 3, and local electrical wiring
code.
Instructions:
Conductor installation:
1. Wiring must comply with all applicable electrical codes.
2. Turn off power before removing or installing disconnect.
3. Strip wires to 3/8 inch (9,5 mm).
4. Grip wire firmly and push conductor into port marked #1 on male connector half.
5. Repeat step 4 for ports #2 up to #6.
6. Repeat steps 4 and 5 for female connector half.
7. Use only one conductor per port and assure that no copper is exposed on any of the
wires inserted.
8. See disconnect de-mate/mate installation instructions on this page when disconnecting
the connector.
9. The wire insertion side of this product is listed for ONE TIME USE ONLY. DO NOT
REMOVE AND REPLACE WIRES.
TABLE 1: Voltage/Current Maximum:
Voltage (V)
Current (A)
600
3
TABLE 2: Wire Size & Type
Wire Type
Wire Size
Solid and Tin Bonded
18 AWG
Copper to copper connections only. Do not use on Aluminum.
IDEAL INDUSTRIES, INC.
Becker Place
Sycamore, IL 60178, U.S.A.
800-435-0705 Customer Assistance
www.idealindustries.com
ND 7638-5
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising