Technika | THM2070NG | Spec sheet | Technika THM2070NG Hot Water System Spec Sheet

Technika THM2070NG Hot Water System Spec Sheet
THM2070NG
Continuous Flow Water Heater
Last updated July 2016
Product Features
• 6 star energy efficiency rating
• 20 litre water capacity
• Pre-set output temperature 55ᵒC
• Max out put temperature 70ᵒC
• External exhaust
• Optional cable controller
• BLDC motor
• Minimum required water-flow: 3L/min
• Constant temperature control
• Overheat Protection: 85ᵒC
• 200Mj/h heat input
• Electronic ignition
• Water Pressure: 0.02 – 0.8 Mpa
• IPX4 Water proof rating
• Solar panel connectivity
• High efficiency burner: 82%
• Sealed combustion chamber
• Oxygen-free copper tank
• Rated voltage: 240V / 50Hz
• Also available in LPG (THM2070LPG)
Design
This hot water system is compact in design. It will fit in
even the tightest locations, making it super easy to
install.
Heat Exchanger Design
Warms water to desired temperature faster. This
model is adjustable up to 70°C for a solar applications
Intelligent PCB
A single PCB with surge and electromagnetic protection
for reliability
Low Pressure Operation
Turns on with just 110kPa(26L) minimum water
pressure.
1.8m Minimum Run Required
Provides greater flexibility of installation using 50°C
limited model.
6 Star Efficiency
Delivery cost saving year in, year out.
Technika.com.au
THM2070NG
Continuous Flow Water Heater
Last updated July 2016
Installation / Joint pipe Diameter
• Gas inlet:
• Cold inlet water:
• Hot inlet water:
G3/4
G1/2
G1/2
• Can connect with Solar Water heater (not provided)
• Also available in LPG (THM2070LPG)
These dimensions are a guide only, please refer to product
manual for up to date dimensions and product information
Dimensions
Width
Height
Depth
Cut-out (mm)
NA
NA
NA
Product (mm)
177
628
413
READ THE INSTRUCTION BOOKLET BEFORE INSTALLING AND USINGTHE APPLIANCE.
The manufacturer will not be responsible for any damage to property or to persons caused by incorrect installation or improper use of the appliance.
The manufacturer is not responsible for any inaccuracies, due to printing or transcription errors, contained in this handout. In addition, the appearance of the
figures reported is also purely indicative.
The manufacturer reserves the right to make changes to its products when considered necessary and useful, without affecting the essential safety and
operating characteristics.
Technika constantly seeks ways to improve the specifications and designs of their products.
Whilst every effort is made to produce up to date literature, this document should not be regarded as an infallible guide.
Actual product only should be used to derive cut out sizes.
All Technika Appliances must be installed by a qualified person/s with adherence to the relevant electrical, plumbing and AGA codes, with compliance being
issued as required by state or national legislation.
Additionally all Technika Upright cookers must have chains installed correctly in adherence to the relevant AGA, and plumbing codes by the Licenced
installer.
For maximum effectiveness and efficiency all rangehoods should be installed with the use of ductwork, by a licenced installer with adherence to the relevant
state and national building codes and regulations.
All Technika appliances are for Domestic use only, and must be installed by a licence installer into Domestic Applications only, without exception and to the
required Authorities guidelines. Any installation outside of this will VOID warranty. (03) 99