Omega | iR2 Series | Owner Manual | Omega iR2 Series Owner Manual

Omega iR2 Series Owner Manual
RoHS 2 Compliant
Series
User’s Guide
Shop online at
omega.com SM
e-mail: info@omega.com
For latest product manuals:
www.omegamanual.info
R2
Communication Manual
omega.com info@omega.com
U.S.A.
Headquarters:
Servicing North America:
Omega Engineering, Inc.
Toll-Free: 1-800-826-6342 (USA & Canada only)
Customer Service: 1-800-622-2378 (USA & Canada only)
Engineering Service: 1-800-872-9436 (USA & Canada only)
Tel: (203) 359-1660
Fax: (203) 359-7700
e-mail: info@omega.com
For Other Locations Visit omega.com/worldwide
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves
the right to alter specifications without notice.
iR2 Serial Communication Register List
Command
Command
Index
Function
Command
Bytes
# Of
Characters
Default value
(ex: with Analog
Output option)
RW
01
SP1
3
6
1003E8
RW
02
SP2
3
6
1003E8
GPRW
03
RDGOFF
3
6
A00000
RW
04
ANLOFF
3
6
C001F4
RW
05
ID
2
4
0000
-
06
N/A
-
-
-
RW
07
INPUT
1
2
02
GPRW
08
RDGCNF
1
2
41
RW
09
AL1CNFG
1
2
81
RW
0A
AL2CNFG
1
2
00
RW
0B
LOOP BREAK TIME
2
4
003B
RW
0C
OUT1CNF
1
2
00
RW
0D
OUT2CNF
1
2
62
RW
0E
RAMPTIME
2
4
0000
RW
0F
ANLSCL
3
6
9186A0
RW
10
COMM.PARAMETERS
1
2
0D
RW
11
COLOR
1
2
09
RW
12
AL1LO
3
6
A003E8
RW
13
AL1HI
3
6
200FA0
GPRW
14
RDGSCL
3
6
100001
RW
15
AL2LO
3
6
A003E8
RW
16
AL2HI
3
6
200FA0
GPRW
17
PB1/DEAD BAND
2
4
00C8
GPRW
18
RESET 1
2
4
00B4
GPRW
19
RATE 1
2
4
0
GPRW
1A
CYCLE 1
1
2
7
-
1B
N/A
-
-
-
GPRW
1C
PB2/DEAD BAND
2
4
00C8
GPRW
1D
CYCLE 2
1
2
7
RW
1E
SOAK TIME
2
4
0
RW
1F
BUS FORMAT
1
2
14
GPRW
20
DATA FORMAT
1
2
2
RW
21
ADDRESS
1
2
1
RW
22
Transit Time Interval
2
4
10
R(W?)
23
?
3
6
814585
RW
24
Miscellaneous
1
2
0
RW
25
C.J. OFFSET ADJ.
3
6
200000
RW
26
Recognition Character
1
2
2A
RW
27
%LOW
1
2
0
RW
28
%HI
1
2
63
RW
30
EMISSIVITY Value
2
4
03E8
RW
31
SLOP Value
2
4
03E8
RW
44
2
4
0000
RW
45
2
4
8000
RW
46
2
4
0000
RW
47
VOLT OFFSET (ANLG.
CAL.)
VOLT SCALE (ANLG.
CAL.)
CURR. OFFSET (ANLG.
CAL.)
CURR.SCALE (ANLG.
CAL.)
2
4
8000
D
01
DISABLE ALARM 1
0
0
-
D
02
DISABLE ALARM 2
0
0
-
D
03
STANDBY
0
0
-
D
04
DISABLE SELF
0
0
-
E
01
ENABLE ALARM 1
0
0
-
E
02
ENABLE ALARM 2
0
0
-
E
03
DISABLE STANDBY
0
0
-
E
04
ENABLE SELF
0
0
-
X
01
0
0
-
X
02
SEND
READING(SGLE.COLR)
SEND PEAK READING
0
0
-
X
03
0
0
-
X
04
0
0
X
05
0
0
U
01
SEND VALLEY
READING
SEND READING(DUAL
COLR)
CALIBRATION (DATA
STRING)
SEND ALARM STATUS
0
0
-
U
03
SEND SW VERSION
0
0
(Dec. #)
V
01
SEND DATA STRING
0
0
-
Z
02
HARD RESET
0
0
-
iR2 Modbus Comm. Register Description List
FUNCTION
CODE
REGISTER
03/04, 06
03/04, 06
(N/A)
(N/A)
03/04, 06
(N/A)
03/04, 06
03/04, 06
03/04, 06
03/04, 06
03/04, 06
03/04, 06
03/04, 06
03/04, 06
(N/A)
03/04, 06
(N/A)
03/04, 06
03/04, 06
(N/A)
03/04, 06
03/04, 06
03/04, 06
03/04, 06
03/04, 06
03/04, 06
(N/A)
03/04, 06
03/04, 06
03/04, 06
03/04, 06
03/04, 06
03/04, 06
03/04, 06
(N/A)
(N/A)
(N/A)
03/04, 06
03/04
03/04
03/04
03/04
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
FUNCTION
SP1: SETPOINT 1 VALUE
SP2: SETPOINT 2 VALUE
(N/A)
(N/A)
ID : Security ID code
(N/A)
I R : INPUT CONFIGURATION (*)
RdG.CNF : READING CONFIG (**)
AL1/ANLG.OUTPUT CNFG
AL2/ANLG.OUTPUT CNFG
LOOP BREAK TIME VALUE
OUTPUT 1 CONFIGURATION
OUTPUT 2 CONFIGURATION
RAMP TIME VALUE
(N/A)
COMM. PARAMETERS
(N/A)
ALARM1 LOW VALUE
ALARM1 HIGH VALUE
(N/A)
ALARM2 LOW VALUE
ALARM2 HIGH VALUE
PB1/DEAD BAND1 VALUE
RESET1 VALUE(Time in Sec.)
RATE 1 VALUE(Time in Sec.)
CYCLE 1 VALUE(Time in Sec.)
(N/A)
PB2/DEAD BAND2 VALUE
CYCLE 2 VALUE(Time in Sec.)
SOAK TIME
BUS FORMAT
DATA FORMAT
ADDRESS
TRANSIT TIME
(N/A)
(N/A)
(N/A)
RECOGNITION CHARACTER
PROCESS VALUE
PEAK VALUE
VALLEY VALUE
SOFTWARE VERSION
NUMBER
of BYTE
2
2
x
x
2
X
1
2
1
1
2
1
1
2
X
1
1
2
2
X
2
2
2
2
2
1
X
2
1
2
1
1
1
2
X
X
X
1
2
2
2
1
Default value
(ex: with Analog
Output option)
03E8
03E8
X
X
0000
X
02
41
81
0000
003B
00
62
0000
X
0D
X
03E8
05DC
X
0320
03E8
00C8
00B4
0000
07
X
00C8
07
0000
14
02
01
0010
X
X
X
2A
(Main Reading)
(*) Format description of Register Location 07:
I R (INPUT CONFIGURATION) FORMAT
BIT POSITION
REGISTER = 07
7
0
0
0
0
6
0
0
0
0
5
0
0
0
0
4
0
0
0
0
3
0
0
0
0
2
0
0
0
0
1
0
1
0
0
1
1
0
0
1
Laser Off
Laser On
Dual Color
Single Color
0
1
0
1
Value to
be read or
written:
Dual Color
Laser Off
00
Dual Color
Laser ON
01
Single Color
Laser Off
02
Single Color
Laser ON
03
(**) Format description of Register Location 08:
RdG (READING CONFIGURATION) FORMAT
BIT POSITION
REGISTER = 08
7
0
0
0
0
1
1
1
1
6
0
0
1
1
0
0
1
1
5
0
1
0
1
0
1
0
1
4
3
0
1
2
0
0
1
0
0
0
1
1
°C
°F
FLtR (FILTER TIME CONSTANT) = 0001
FLtR (FILTER TIME CONSTANT) = 0002
FLtR (FILTER TIME CONSTANT) = 0004
FLtR (FILTER TIME CONSTANT) = 0008
FLtR (FILTER TIME CONSTANT) = 0016
FLtR (FILTER TIME CONSTANT) = 0032
FLtR (FILTER TIME CONSTANT) = 0064
FLtR (FILTER TIME CONSTANT) = 0128
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a
period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace
period to the normal one (1) year product warranty to cover handling and shipping time. This ensures
that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service
Department will issue an Authorized Return (AR) number immediately upon phone or written request.
Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no
charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser,
including but not limited to mishandling, improper interfacing, operation outside of design limits,
improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of
having been tampered with or shows evidence of having been damaged as a result of excessive corrosion;
or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating
conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not
limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However,
OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for
any damages that result from the use of its products in accordance with information provided
by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the
company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR
REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF
TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF
LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of
OMEGA with respect to this order, whether based on contract, warranty, negligence,
indemnification, strict liability or otherwise, shall not exceed the purchase price of the
component upon which liability is based. In no event shall OMEGA be liable for
consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic
Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical
applications or used on humans. Should any Product(s) be used in or with any nuclear installation or
activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility
as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify
OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the
Product(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE
RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR)
NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING
DELAYS). The assigned AR number should then be marked on the outside of the return package and on any
correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent
breakage in transit.
FOR NON-WARRANTY REPAIRS, consult
FOR WARRANTY RETURNS, please have the
OMEGA for current repair charges. Have
following information available BEFORE contacting
the following information available BEFORE
OMEGA:
contacting OMEGA:
1.Purchase Order number under which the product
1. Purchase Order number to cover the COST
was PURCHASED,
of the repair,
2.Model and serial number of the product under
2. Model and serial number of the product, and
warranty, and
3. Repair instructions and/or specific problems
3. Repair instructions and/or specific problems
relative to the product.
relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our
customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2017 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior
written consent of OMEGA ENGINEERING, INC.
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
Shop online at omega.com SM
TEMPERATURE
M
U Thermocouple, RTD & Thermistor Probes, Connectors,
Panels & Assemblies
M
U Wire: Thermocouple, RTD & Thermistor
M
U Calibrators & Ice Point References
M
U Recorders, Controllers & Process Monitors
M
U Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
M
U Transducers & Strain Gages
M
U Load Cells & Pressure Gages
M
U Displacement Transducers
M
U Instrumentation & Accessories
FLOW/LEVEL
M
U Rotameters, Gas Mass Flowmeters & Flow Computers
M
U Air Velocity Indicators
M
U Turbine/Paddlewheel Systems
M
U Totalizers & Batch Controllers
pH/CONDUCTIVITY
M
U pH Electrodes, Testers & Accessories
M
U Benchtop/Laboratory Meters
M
U Controllers, Calibrators, Simulators & Pumps
M
U Industrial pH & Conductivity Equipment
DATA ACQUISITION
M
U Communications-Based Acquisition Systems
M
U Data Logging Systems
M
U Wireless Sensors, Transmitters, & Receivers
M
U Signal Conditioners
M
U Data Acquisition Software
HEATERS
M
U Heating Cable
M
U Cartridge & Strip Heaters
M
U Immersion & Band Heaters
M
U Flexible Heaters
M
U Laboratory Heaters
ENVIRONMENTAL
MONITORING AND CONTROL
M
U Metering & Control Instrumentation
M
U Refractometers
M
U Pumps & Tubing
M
U Air, Soil & Water Monitors
M
U Industrial Water & Wastewater Treatment
M
U pH, Conductivity & Dissolved Oxygen Instruments
M4911/0717
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising