OM-EL-CC-1 RANGE
Cold Chain Data Logging Solutions
omega.com info@omega.com
U.S.A.
Headquarters:
Servicing North America:
Omega Engineering, Inc.
Toll-Free: 1-800-826-6342 (USA & Canada only)
Customer Service: 1-800-622-2378 (USA & Canada only)
Engineering Service: 1-800-872-9436 (USA & Canada only)
Tel: (203) 359-1660
Fax: (203) 359-7700
e-mail: info@omega.com
For Other Locations Visit omega.com/worldwide
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves
the right to alter specifications without notice.
OM-EL-CC-1 Range
Cold Chain Data Logging Solutions
M-5665/0717
Shop online at omega.com SM e-mail: info@omega.com
For latest product manuals: omegamanual.info
1
Your new logger comes ready to go.
Simply press and hold the
button until the green LED lights up to start logging.
Push to start
Preset high and
low alarm levels
Status LEDs
2
Now place your logger in the location you want to monitor.
Once logging, pressing the
button will light up an LED to give a quick indication of the
status. It will also add a marker to the data to show that you have checked it.
No alarms will be triggered in the first 30 minutes to allow the logger to settle at the
monitored temperature.
Green single flash
The data logger is currently logging
No alarm has been triggered
No action required
Red single flash
The data logger is currently logging
An alarm has been triggered!
Check alarm condition in PC software
Green double flash
The data logger’s memory is full
No alarm was triggered
Plug your logger in to a PC, download
your readings and start a new session
Red double flash
The data logger’s memory is full
An alarm was triggered!
Plug your logger in to a PC, download
your readings, check alarm condition
and start a new session
No LEDs flash
The data logger is stopped or the battery is flat
Check the logger’s status using the PC
software
3
When you are ready to view the recorded data on your logger, the first thing you
need to do is download the free software.
Visit www.omega.com and click on the download link.
Double click on the downloaded .exe file, and follow the on screen prompts.
4
To save your data, remove the logger from the plastic sleeve and connect it to a USB port.
Open the software and click on Save Data.
This will automatically open up your readings in the software, where you can view
your data or export it in various formats.
5
To start your logger for the next session, click on Prime Logger.
Your data logger is now primed and ready to go. Place your logger in location ready
for the next session. To start it logging again, press and hold the
button until the
green LED lights up.
The OM-EL-CC-1 Range
ALARMS:
HIGH 8°C
LOW 2°C
CHILLED GOODS
STATUS:
OM-EL-CC-1-001
Chilled Goods
High Alarm 8°C
Low Alarm 2°C
ALARMS:
HIGH -16°C
LOW -20°C
FROZEN GOODS
STATUS:
OM-EL-CC-1-002
Frozen Goods
High Alarm -16°C
Low Alarm -20°C
ALARMS:
HIGH 14°C
LOW 12°C
RIPENING GOODS
STATUS:
OM-EL-CC-1-003
Ripening Goods
High Alarm 14°C
Low Alarm 12°C
OM-EL-CC-1-Range
Cold Chain Data Logging Solutions
• 3 data loggers for monitoring Chilled Goods, Frozen Goods
and Ripening Goods.
• No set-up required. One button press-to-start logging.
• Pre-configured with appropriate sample rates and alarm thresholds
for each application.
• Reusable with 12+ months battery life.
• Various export options including PDF, Microsoft Excel and JPEG.
Each of the three Cold Chain loggers comes pre-configured for use in your
particular application – simply press the button to start logging. During a
logging session, pressing the button will light up the status LEDs to give a quick
indication as to whether the temperature has exceeded an alarm condition at any
point. Once your session has been completed, tear open the IP67-rated plastic
wallet to reveal the USB connector and plug it in to your PC. Use the free software
for Windows to download and graph the data, and then prime your logger for its
next use.
Omega CC Software
The simple-to-use software allows you to view the data
graphically, in a table or export it in various formats for use
in further reporting.
Download the latest version of the software free of
charge from www.omega.com
YOUR OM-EL-CC-1
1
2
Status LEDs
USB connector
4
Tear to open
5
Mounting point
6
Model type
3
6
2
4
67 mm (2.6”)
MODEL SPECIFIC
SPECIFICATIONS
5
1
48 mm (1.8”)
3
Start / Status button
Measurement range
-30 to +60°C (-22 to +140°F)
Accuracy (overall error)
±0.5°C maximum (±1°F)
Resolution
0.1°C (0.1°F)
Battery Life
12 months (minimum)
IP Rating
IP67*
Readings
32,600
* The data logger is protected against moisture to IP67 standard when
housed in an OM-EL-CC-BAG or equivalent.
Chilled Goods
Frozen Goods
Ripening Goods
High Alarm Level
8°C
-16°C
14°C
Low Alarm Level
2°C
-20°C
12°C
Logging Interval
10 minutes (220 days)
10 minutes (220 days)
10 minutes (220 days)
Part Number
OM-EL-CC-1-001
OM-EL-CC-1-002
OM-EL-CC-1-003
This unit can be quickly customized for use in multiple markets. If you have a specific monitoring application, that requires different
sample rates or alarm thresholds, call us today.
ACCESSORIES
OM-EL-CC-BAG: Pack of 5 waterproof bags for data logger during use.
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a
period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month
grace period to the normal one (1) year product warranty to cover handling and shipping time. This
ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service
Department will issue an Authorized Return (AR) number immediately upon phone or written request.
Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no
charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser,
including but not limited to mishandling, improper interfacing, operation outside of design limits,
improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of
having been tampered with or shows evidence of having been damaged as a result of excessive corrosion;
or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating
conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not
limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However,
OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for
any damages that result from the use of its products in accordance with information provided
by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the
company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR
REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF
TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF
LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of
OMEGA with respect to this order, whether based on contract, warranty, negligence,
indemnification, strict liability or otherwise, shall not exceed the purchase price of the
component upon which liability is based. In no event shall OMEGA be liable for
consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic
Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical
applications or used on humans. Should any Product(s) be used in or with any nuclear installation or
activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility
as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify
OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the
Product(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department.
BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED
RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID
PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return
package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent
breakage in transit.
FOR NON-WARRANTY REPAIRS, consult
FOR WARRANTY RETURNS, please have the
OMEGA for current repair charges. Have
following information available BEFORE contacting
the following information available BEFORE
OMEGA:
contacting OMEGA:
1.Purchase Order number under which the product
1.
Purchase Order number to cover the COST
was PURCHASED,
of the repair,
2.Model and serial number of the product under
2. Model and serial number of the product, and
warranty, and
3. Repair instructions and/or specific problems
3. Repair instructions and/or specific problems
relative to the product.
relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords
our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2016 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the
prior written consent of OMEGA ENGINEERING, INC.
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
Shop online at omega.com SM
TEMPERATURE
M
U Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
M
U Wire: Thermocouple, RTD & Thermistor
M
U Calibrators & Ice Point References
M
U Recorders, Controllers & Process Monitors
M
U Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
M
U Transducers & Strain Gages
M
U Load Cells & Pressure Gages
M
U Displacement Transducers
M
U Instrumentation & Accessories
FLOW/LEVEL
M
U Rotameters, Gas Mass Flowmeters & Flow Computers
M
U Air Velocity Indicators
M
U Turbine/Paddlewheel Systems
M
U Totalizers & Batch Controllers
pH/CONDUCTIVITY
M
U pH Electrodes, Testers & Accessories
M
U Benchtop/Laboratory Meters
M
U Controllers, Calibrators, Simulators & Pumps
M
U Industrial pH & Conductivity Equipment
DATA ACQUISITION
M
U Communications-Based Acquisition Systems
M
U Data Logging Systems
M
U Wireless Sensors, Transmitters, & Receivers
M
U Signal Conditioners
M
U Data Acquisition Software
HEATERS
M
U Heating Cable
M
U Cartridge & Strip Heaters
M
U Immersion & Band Heaters
M
U Flexible Heaters
M
U Laboratory Heaters
ENVIRONMENTAL
MONITORING AND CONTROL
M
U Metering & Control Instrumentation
M
U Refractometers
M
U Pumps & Tubing
M
U Air, Soil & Water Monitors
M
U Industrial Water & Wastewater Treatment
M
U pH, Conductivity & Dissolved Oxygen Instruments
M-5665/0717
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising