Omega | OS758-LS | Owner Manual | Omega OS758-LS Owner Manual

Omega OS758-LS Owner Manual
TM
User’s Guide
Shop online at
omega.com
e-mail: info@omega.com
For latest product manuals:
www.omegamanual.info
NORWALK, CT
OS758-LS
Non-contact Infrared
Thermometer
omega.com info@omega.com
Servicing North America:
Omega Engineering, Inc.
U.S.A.
Headquarters: 800 Connecticut Ave, Suite 5N01, Norwalk CT 06854
Toll-Free: 1-800-826-6342 (USA & Canada only)
Customer Service: 1-800-622-2378 (USA & Canada only)
Engineering Service: 1-800-872-9436 (USA & Canada only)
Tel: (203) 359-1660
Fax: (203) 359-7700
e-mail: info@omega.com
For Other Locations Visit omega.com/worldwide
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves
the right to alter specifications without notice.
OS758-LS Thermometer Operating Instructions
For Model with thermocouple socket
The thermometer is a non-contact infrared thermometer. There are many mathematical modes for the Infrared function. Please remember to keep
away from children and don’t use it for safety related applications.
*Dual laser points
specify the
(Default Screen)
approximate
measurement
area for better
targeting
.
7 ) and press Meas. key (○
6 ) to display the surface temperature. The
Simply aim the thermometer at the measure target with Lens (○
Distance:Spot is 60:1. Please make sure the target area is within the field of view.
11 up to enable the function..
** Data logger function(SD Card、USB): Please push “Micro SD Card Switch”○
2 ) for scrolling more display function as follows.
FUNCTION Press Mode key (○
Here will show the emissivity data. (The default emissivity is 0.95.)
2 ), then press Up key (○
4 ) or Down key (○
3 ) to set the emissivity, then press Mode key (○
2 ) to confirm it.
Press Mode key (○
The emissivity can be changed from 0.10 (10E) to 1 (100E).
2 ) for the Maximum (MAX), Minimum (MIN), Different between MAX and MIN (DIF) and Average (AVG)
Press Mode key (○
modes. During the measurement, the special modes reading will be displayed beside the mode icon.
4 ) or Down key (○
3 ) to change the High Alarm (HAL) or Lo Alarm (LAL), then press Meas. key (○
6 ) to confirm
Press Up key (○
o
o
it. For example: When the reading 26.9 C < LAL 27 C, the Low icon will flash and you will hear a beep sound.
5 ) and put the probe in/on the target, the thermometer will display the
Connect the thermocouple with Thermocouple socket (○
temperature automatically without pressing any button. To see the minimum or maximum data during the probe measurement,
4 ) or Down key (○
3 ).
please hold down the Up key (○
After measure high temp, the probe may remain HOT for a while.
2 ) for the Memory (M00), then press Meas. key (○
6 ) to save the measurement.
After taking the temperature, press Mode key (○
4
3
Under the Memory (M00), press Up key (○) or Down key (○) key to display the record.
** The thermometer will automatically shut off if left idle for more than 60sec., unless in PRB mode. (In PRB mode, it will shut off if left idle for
more than 12 minutes.)
ADD VALUE
In E, MAX, MIN, DIF, AVG
mode:
4 ) for LOCK mode ON/OFF. The lock mode is particularly useful for continuous monitoring of
Press Up key (○
temperatures for up to 60 minutes.
o
o
3 ) for C or F transferred.
Press Down key (○
shows RED color when the reading is close to maximum value,
In MAX, MIN mode: Hold on and shows BLUE when close to minimum. While the
6 )
the Meas. key (○
temperature is between the maximum and minimum, the bar will
display in YELLOW.
In all modes: First hold on LCD Backlight: always on.
6 )
3 ) for laser function ON/OFF.
the Meas. key (○
and press Down key (○
CAUTION
1. WHEN DEVICE IS IN USE, DO NOT LOOK DIRECTLY INTO THE LASER BEAM–PERMANENT EYE DAMAGE MAY RESULT.
2. USE EXTREME CAUTION WHEN OPERATING THE LASER.
3. NEVER POINT THE DEVICE TOWARDS ANYONE’S EYES.
4. KEEP OUT OF REACH OF ALL CHILDREN.
STORAGE & CLEANING
It should be stored at room temperature. The sensor lens is the most delicate part of the thermometer. The lens should be kept clean at all times,
care should be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol, allowing the lens to fully dry
before using the thermometer. Do not submerge any part of the thermometer.
LCD ERROR MESSAGES
The thermometer incorporates visual diagnostic messages as follows:
‘Hi’ or ’Lo’ is displayed when the temperature being measured is outside of the settings of HAL and LAL.
「
」 「
「
「
」
」
」
「
」
‘Er2’ is displayed when the thermometer is exposed to rapid changes in the ambient temperature. ‘Er3’
o
o
is displayed when the ambient temperature exceeds 0 C (32°F) or +50 C (122°F). The thermometer
should be allowed plenty of time (minimum 30 minutes) to stabilize to the working/room temperature.
Error 5~9, for all other error messages it is necessary to reset the thermometer. To reset it, turn the
instrument off, remove the battery and wait for a minimum of one minute, reinsert the battery and turn
on. If the error message remains please contact the Service Department for further assistance.
‘Hi’ or ’Lo’ is displayed when the temperature being measured is outside of the measurement range.
BATTERIES
The thermometer incorporates visual low battery indication as follows:
‘Battery OK’: measurements
‘Battery Low’: battery needs to be
‘Battery Exhausted’: measurements are not
are possible
replaced, measurements are still possible
possible
When the ‘Low Battery’ icon indicates the battery is low, the battery should be replaced immediately with AA, 1.5V batteries. Please note: It is
important to turn the instrument off before replacing the battery otherwise the thermometer may malfunction.
Dispose of used battery promptly and keep away from children.
SPECIFICATION
Item
Measurement Range
Operating Range
Non-contact Infrared Scan function
o
o
Thermocouple Probe Scan function
(K type; probe not included.)
-64 to +1400°C (-83.2 to +2552°F)
-35 to +1600 C (-31 to +2912 F)
0 to +50°C (32 to +122°F)
Tobj=-35~0: ±(2°C+0.05/degC)°C,
±1% of reading or 1°C (1.8°F) whichever is
Accuracy(Tamb=23±3°C)
greater (Test under Tamb=23±6°C)
Tobj=0~1600: ±2% of reading or 2°C (4°F) whichever is greater
Emissivity Range
0.95 default – adjustable 0.1 to 1 step .01
Resolution
0.1°C/0.1°F at -83.2 to 999.9(°C/°F), otherwise 1°C/1°F
Spectral Range
8~14μm
Response Time (90%)
1sec
Distance:Spot
60:1 (90% energy covered)
Internal Memory
Detailed 24 Memories with Temperature & Emissivity
Support 8G micro SD card (Recommend to use the attached SD card).
External Memory Type
11
If SD card data logger is failed, please reset the switch○
USB Function
Please download the program from CD. (CD & USB cable are enclosed with the package)
Output Interface
SPI, USB, SD card
Battery Life
Typical 14, min 10 hours continuous use (Alkaline, with laser and backlight)
Dimensions
202.99*176.07*58.31 mm (7.99×6.93×2.30 inch)
Weight
401 grams (14.14 oz) including batteries (AA*2pcs)
o
o
Note: Under the electromagnetic field of 3V/m from180 to600 MHz, the maximum error is 10 C (18 F).
Caution: The measure range is for thermometer only. User should choose proper probe types for different kinds of application.
Please make sure the target to be measured will not exceed the temperature range of the probe to avoid permanent damage of
the thermocouple probe.
Caution: To avoid electric shock and thermometer damage, do not measure live circuit where voltage exceeding 24V AC RMS or
60V DC with the thermocouple probe.
EMC/RFI: Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of
approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.
Ref.No.:062017
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a
period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month
grace period to the normal one (1) year product warranty to cover handling and shipping time. This
ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service
Department will issue an Authorized Return (AR) number immediately upon phone or written request.
Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no
charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser,
including but not limited to mishandling, improper interfacing, operation outside of design limits,
improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of
having been tampered with or shows evidence of having been damaged as a result of excessive corrosion;
or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating
conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not
limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However,
OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for
any damages that result from the use of its products in accordance with information provided
by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the
company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR
REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF
TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF
LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of
OMEGA with respect to this order, whether based on contract, warranty, negligence,
indemnification, strict liability or otherwise, shall not exceed the purchase price of the
component upon which liability is based. In no event shall OMEGA be liable for
consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic
Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical
applications or used on humans. Should any Product(s) be used in or with any nuclear installation or
activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility
as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify
OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the
Product(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department.
BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED
RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID
PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return
package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent
breakage in transit.
FOR NON-WARRANTY REPAIRS, consult
FOR WARRANTY RETURNS, please have the
OMEGA for current repair charges. Have
following information available BEFORE contacting
the following information available BEFORE
OMEGA:
contacting OMEGA:
1. Purchase
Order number under which the product
1. Purchase Order number to cover the COST
was PURCHASED,
of the repair,
2. Model
and serial number of the product under
2. Model and serial number of the product, and
warranty, and
3. Repair instructions and/or specific problems
3. Repair instructions and/or specific problems
relative to the product.
relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords
our customers the latest in technology and engineering.
OMEGA is a trademark of OMEGA ENGINEERING, INC.
© Copyright 2019 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the
prior written consent of OMEGA ENGINEERING, INC.
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
Shop online at omega.com
TEMPERATURE
M
U Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
M
U Wire: Thermocouple, RTD & Thermistor
M
U Calibrators & Ice Point References
M
U Recorders, Controllers & Process Monitors
M
U Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
M
U Transducers & Strain Gages
M
U Load Cells & Pressure Gages
M
U Displacement Transducers
M
U Instrumentation & Accessories
FLOW/LEVEL
M
U Rotameters, Gas Mass Flowmeters & Flow Computers
M
U Air Velocity Indicators
M
U Turbine/Paddlewheel Systems
M
U Totalizers & Batch Controllers
pH/CONDUCTIVITY
M
U pH Electrodes, Testers & Accessories
M
U Benchtop/Laboratory Meters
M
U Controllers, Calibrators, Simulators & Pumps
M
U Industrial pH & Conductivity Equipment
DATA ACQUISITION
M
U Communications-Based Acquisition Systems
M
U Data Logging Systems
M
U Wireless Sensors, Transmitters, & Receivers
M
U Signal Conditioners
M
U Data Acquisition Software
HEATERS
M
U Heating Cable
M
U Cartridge & Strip Heaters
M
U Immersion & Band Heaters
M
U Flexible Heaters
M
U Laboratory Heaters
ENVIRONMENTAL
MONITORING AND CONTROL
M
U Metering & Control Instrumentation
M
U Refractometers
M
U Pumps & Tubing
M
U Air, Soil & Water Monitors
M
U Industrial Water & Wastewater Treatment
M
U pH, Conductivity & Dissolved Oxygen Instruments
M5601/0119
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising