Omega | TXDIN402 | Owner Manual | Omega TXDIN402 User manual

Omega TXDIN402 User manual
Safety guide lines / Norme di sicurezza
Read carefully the safety guidelines and programming instructions contained in
this manual before using/connecting the device.
Only qualified personnel should be allowed to use the device and/or service it
and in accordance to technical data and environmental conditions listed in this
manual.
Do not dispose electric tools together with household waste material. In
observance European Directive 2002/96/EC on waste electrical and electronic
equipment and its implementation in accordance with national law, electric tools
that have reached the end of their life must be collected separately and returned
to an environmentally compatible recycling facility.
Prima di utilizzare il dispositivo, leggere con attenzione le istruzioni e le
misure di sicurezza contenute in questo manuale.
L’utilizzo/manutenzione è riservato a personale qualificato ed è da intendersi
esclusivamente nel rispetto dei dati tecnici e delle condizioni ambientali
dichiarate.
Non gettare le apparecchiature elettriche tra i rifiuti domestici.
Secondo la Direttiva Europea 2002/96/CE, le apparecchiature elettriche
esauste devono essere raccolte separatamente al fine di essere reimpiegate o
riciclate in modo eco-compatibile.
2
Dimensions / Dimensioni
DIN3880 1 Mod.
90 mm
6
5
+Vdc
SUPPLY
6...32Vdc
Out
mA
18 mm
4
1
-
V
Ohm
+
mA
+
RFID
N
RU
7
64 mm
N
RU
Grazie per aver scelto un prodotto Omega.
Lo strumento TXDIN401 converte un segnale di resistenza / corrente /
tensione in un segnale normalizzato in corrente per loop 4..20 mA (tecnologia
2 fili).
Le caratteristiche dello strumento sono:
• Elevata precisione;
• Conversione della misura a 16 bit;
• Programmabilità via RFid (NFC);
• 2624 Word di memoria non volatile (buffer circolare) per data-logging con
tempo di campionamento impostabile dall’utente;
• Possibilità di riscalare l’uscita 4..20mA rispetto all’ingresso;
• Ridotto ingombro;
• Tramite il software RF Programmer (scaricabile dal sito omega.com) e il
programmatore TX400-RFID, è possibile:
configurare completamente il convertitore;
scaricare sul pc il logging registrato;
visualizzare e stampare la curva resistenza-tempo / correntetempo / tensione-tempo
1
2
Thanks for choosing a Omega device.
The TXDIN401 converts a resistance, current or voltage signals into a current
signal for 4..20mA loop (2 wires).
Main features are:
• High accuracy;
• 16bit conversion;
• Programmable by RFid (NFC);
• 2624 Word non-volatile memory (circular buffer) for data-logging with
sampling time selectable by the user;
• Possibility to rescale the output 4..20mA compared to input value;
• Compact dimensions;
• The software RF Programmer (available for download on Omega website)
and the TX400-RFID allow:
complete configurability of the device;
download on PC of logged data;
visualization/printing of the resistance - time / current - time and
voltage - time trend.
3
Introduction / Introduzione
Attacco a guida DIN EN50022
Din rail mounting guide EN50022
omega.com info@omega.com
Servicing North America:
1 YEAR 2 YEAR
U.S.A.:Omega Engineering, Inc., One Omega Drive, P.O. Box 4047, Stamford, CT 06907-0047 USA
Toll-Free: 1-800-826-6342 (USA & Canada only), Customer Service: 1-800-622-2378 (USA & Canada only)
Engineering Service: 1-800-872-9436 (USA & Canada only),
Tel: (203) 359-1660, Fax: (203) 359-7700
e-mail: info@omega.com
For Other Locations Visit omega.com/worldwide
User’s Guide
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any
errors it contains, and reserves the right to alter specifications without notice.
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period
of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to
the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s
customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department
will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by
OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY
does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling,
improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This
WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having
been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification;
misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is
not warranted, include but are not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA
neither assumes responsibility for any omissions or errors nor assumes liability for any
damages that result from the use of its products in accordance with information provided by
OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the
company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR
REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF
TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF
LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability
of OMEGA with respect to this order, whether based on contract, warranty, negligence,
indemnification, strict liability or otherwise, shall not exceed the purchase price of the
component upon which liability is based. In no event shall OMEGA be liable for consequential,
incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic
Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical
applications or used on humans. Should any Product(s) be used in or with any nuclear installation or
activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility
as set forth in our basic WARRANTY / DISCLAIMER language, and, additionally, purchaser will indemnify
OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the
Product(s) in such a manner.
Shop online at
omega.com SM
e-mail: info@omega.com
For latest product manuals:
omegamanual.info
RETURN REQUESTS / INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE
RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR)
NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING
DELAYS). The assigned AR number should then be marked on the outside of the return package and on any
correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent
breakage in transit.
FOR WARRANTY RETURNS, please have the following FOR NON-WARRANTY REPAIRS, consult OMEGA
information available BEFORE contacting OMEGA:
for current repair charges. Have the following
1.Purchase Order number under which the product information available BEFORE contacting OMEGA:
was PURCHASED,
1.Purchase Order number to cover the COST of the
repair,
2.Model and serial number of the product under
warranty, and
2. Model and serial number of the product, and
3.Repair instructions and/or specific problems relative 3.Repair instructions and/or specific problems
to the product.
relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible.
This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of
OMEGA ENGINEERING, INC.
© Copyright 2015 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied,
photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in
whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
M5589/0716
TXDIN402
DIN Rail Mount Voltage / Current /
Resistance Input Transmitter RFID
3
Technical Data / Dati tecnici
3.1 General data / Caratteristiche generali
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Operating range
Range funzionamento
Current output
Uscita in corrente
Functional insulation
Isolamento funzionale
Output resolution
Risoluzione in uscita
Upper Linearity Limit
Limite linearità superiore
Lower Linearity Limit
Limite linearità inferiore
Failure output
Uscita guasto
Current output protection
Protezione uscita in corrente
Rejection / Reiezione
Max transmission error
Max errore di trasmissione
EMI
Temperature coefficient
Coefficiente di temperatura
Sampling time
Tempo di campionamento
Response time (10..90%)
Tempo di risposta (10..90%)
Sealing / Grado di protezione
Conformity / Normative
6-32 Vdc
4..20 mA (2 wires) / 4..20 mA (2 fili)
1K Vac
2 μA
f.s. + 5°C
f.s. - 5°C
selectable 21mA, 3,8mA or anyone
selezionabile tra 21mA, 3,8mA o nessuno
30 mA approx.
30 mA circa
50-60 Hz
0,1% f.s.
< 0,5%
< 100 ppm
300 ms
approx. 600 ms
IP 20
CE, EN 61000-6-4, EN 61000-6-2
La configurazione di questo convertitore di segnale richiede l’utilizzo
di un programmatore (TX400-RFID) e del software di configurazione RF
Programmer scaricabile dal sito www.omega.com.
Dopo aver connesso tramite porta USB il TX400-RFID e attivato il software è
possibile con la modalità “EDIT” parametrizzare il dispositivo selezionando il
tipo di sensore, range di misura, uscita per segnalazione errore e la frequenza
di campionamento per la registrazione. Con i tasti “WRITE” e “READ” è
possibile scrivere e leggere i vari dispositivi velocemente e in modo agevole.
Nella parte bassa dello schermo appare la lista riassuntiva dei dispositivi
programmati, che può essere stampata per certificare la buona riuscita delle
operazioni.
3.2 Thermo-mechanic features / Caratteristiche
termomeccaniche
4
5
6
7
8
4
30-90% @ 40°C (non condensing / senza
condensa)
-40..+105°C
Screw pins / Morsetti a vite
1 mm2
8 mm
nylon (PA66)
23 mm, Ø 45 mm
6..32Vdc
Inputs / Ingressi
Current input
Ingresso corrente
Voltage input
Ingresso tensione
Resistance input
Ingresso resistenza
N
3
-40..+85 °C
RU
2
Operating temperature
Temp. di funzionamento
Humidity
Umidità
Storage temperature
Temperatura di stoccaggio
Connections / Connessioni
Conductors section
Sezione conduttori
Wires strip
Spelatura conduttori
Enclosure / Custodia
Dimensions / Dimensioni
4..20mA
Measuring
range: 0..20 mA (default 4 - 20 mA)
Range di misura: 0..20 mA (default 4 - 20 mA)
Measuring range: 0..10 V
Range
di misura: 0..10 V
6..32Vdc
+
Measuring range: 0..4000 Ω
Range di misura: 0..4000 Ω
RU
N
1
4..20mA
4.1 Connections / Connessioni
6..32Vdc
RU
N
Resistance input
Ingresso resistenza
4..20mA
6..32Vdc
4..20mA
RU
N
Current input
Ingresso corrente
RU
N
6..32Vdc
4..20mA
6..32Vdc
4..20mA
RU
N
+
6..32Vdc
+
RU
N
Voltage input
Ingresso tensione
4..20mA
5
Configuration
/ Configurazione
6..32Vdc
RU
N
RU
N
To configure this signal converter it is necessary to use a TX400-RFID and the
configuration software6..32Vdc
RF Programmer, available on www.omega.com.
4..20mA
After connecting the TX400-RFID
via USB and activating the software is possible,
4..20mA the device input sensor, measuring range, output
in “EDIT” mode, to configure
current value and sampling frequency for the registration. The keys “WRITE”
and “READ” allow to write and read data on the devices quickly and easily. On
the lower side of the display a list of all programmed devices is showed; it can be
printed to confirm that the programming has been completed successfully.
The input range can be set manually through the button placed under the frontal
closing cover. Press this button for 6s to access the configuration mode and set
the min. input value (slow flashing LED). Release the button to store the input
value which will be related to the min. output value (set on the corresponding
parameter, modification is possible only by a specific application, default 4mA).
Pressing the button for a further 6s it is possible to set the max. input value (fast
flashing LED). Release the button to store the input value which will be related
to the max. output value (set on the corresponding parameter, modification is
possible only by a specific application, default 4mA).
Input / output correspondence can be also set by a linearization table which is
editable through a specific software or smartphone application. More instructions
are available on the software manual.
La pressione prolungata per 6 secondi permette di accedere alla modalità
di configurazione per impostare il valore minimo di ingresso (segnalata dal
lampeggio lento del led). Il rilascio del pulsante corrisponde al salvataggio
del valore letto in ingresso, che verrà associato al valore minimo di uscita
(valore impostato sul parametro corrispondente, la modifica è possibile solo
da apposita applicazione, default 4mA). La pressione prolungata per ulteriori
6 secondi permette di impostare il valore massimo di ingresso (segnalata dal
lampeggio veloce del led). Il rilascio del pulsante corrisponde al salvataggio
del valore letto in ingresso, che verrà associato al valore massimo di uscita
(valore impostato sul parametro corrispondente, la modifica è possibile solo
da apposita applicazione, default 20mA). La corrispondenza ingresso/uscita è
anche impostabile per mezzo di una tabella di linearizzazione la cui modifica
è possibile tramite l’apposito software o app per smartphone. Ulteriori
istruzioni sono disponibili nel manuale del software.
6
Data Logger
This signal converter is provided with a datalogging function for the input signal.
Fixing the sampling time (1..3600 seconds) each time the loop 4..20mA powers the
device up, this will store the input value into a non-volatile memory. Through the
TX400-RFID it is possible to download / display / print all data.
Questo convertitore di segnale è provvisto di una capacità di storicizzazione
del segnale in ingresso. Fissando il tempo di campionamento (impostabile
tra 1 e 3600 sec.) ogni volta che il loop 4..20mA alimenterà il dipositivo
questo archivia il valore in ingresso su una memoria non volatile. Tramite il
TX400-RFID è possibile scaricare tutti i dati e presentarli a video o stamparli.
Was this manual useful for you? yes no